DOSING PUMPSAgriculture | Livestock | Industry
DOSING PUMPS
2 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
Tefen is a leading manufacturer of environmental
friendly, non-electric volumetric equipment and flow
products since 1973.
Tefen's MixRite line of water driven proportional dosing
pumps, are used to ensure precise additive injection
directly into the water or fluid line under various flow
rates, feed ratios and different ranges of pressure.
These injectors are extremely durable, manufactured
from engineered composite materials to withstand
the rigors of the elements, as well as chemicals and
acids for injection.
Tefen offers the MixRite pumps for a variety of
applications such as medication for livestock, cleaning
or disinfecting fluid lines, sanitizing water systems,
car wash, cost effective fertilizing, and pest control
for crops and plants. Tefen's injectors are adaptable
simple to use and cost effective, while creating a
long-lasting solution for your needs.
The Tefen MixRite water powered dosing pump is a
simple, user friendly and ingenious system that has
demonstrated its value in over 90 countries.
Tefen is certified by ISO 9001 2008
DOSING PUMPSAbout TEFEN
Applications
Animal HealthThe MixRite medicators for Animal Health guarantee control over doses of treatments injected through drinking water, which is the ideal distribution method, from the first day of the flock. In all kinds of Animal (poultry, pigs, cattle, rabbits, etc.), the MixRite proportional dosing medicators will enable you to dose Into the water line treatments such as: Medications, Vaccines, Disinfectants, Acidification, Chlorine, Supplements, Vitamins, Minerals. The proportionality of MixRite medicators guarantees the correct dose independently by pressure and water flow variations (animal consumption).
FertilizingThe objectives of fertigation are to control water quantities and added nutrients necessary for optimum growth of crops. MixRite proportional injection technology means less waste, plus a better mix for fertilizers, pesticides and other water-soluble products.
Cleaning or disinfecting fluid linesMixRite water powered proportional dosing pumps can be used for automatic preparation of disinfecting, lubricating and detergent solutions. MixRite injectors operate without electricity, they can also be used in remote areas for water purification to prevent and control disease.
Car washingMixRite pumps are the perfect solution for car wash facilities of all types and sizes. It lowers the cost-per-car expense, while using less energy and chemical waste.
Sanitizing water systemsThe sanitation and hygiene industry requires exceedingly accurate and reliable chemical mixing and injection solutions. MixRite injectors are used in market applications like hospitals, restaurants, food services, and supermarkets. MixRite pumps are easily installed in fixed or mobile installations often including static mixers, maturing tanks, flow meters, etc.
DOSING PUMPS | 3
DOSING PUMPS
4 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
Selected dosingproportion
Fresh water Water + % additive
Additive
Dosing adjustment sleeve
Mixing motor
■ Mixes additive and water precisely ■ The dosage can be adjusted easily and quickly ■ Repair is simple and inexpensive ■ Key internal parts are from the highest quality material available (hastelloy spring. Viton Rubber seal)
Advantages ■ Works at low flow rate ■ Easy to field maintenance ■ Highly chemical resistant ■ Good blending ■ Highly resistant to UV damage ■ Easy to install ■ No electricity needed ■ Easy to adjust dosing rate ■ Replaceable seals
Determining the right MixRite model for each application is done according to the customer’s needs and the system specifications.
Operating principleThe unit will automatically start working when water is flowing in the water line and continue until the flow will stop; it is possible to control the suction (intake) operation by using the models with the On/Off system.
The injection rate is set up manually by rotating the sleeve to the desired proportion. The amount of injected concentrate is proportional to the amount of water flowing into the MixRite pump.
Adjusting the MixRite pump
Features
DOSING PUMPS | 5
14 2
35
7
Main Water pipe
6
Very important to install Filter
Simple maintananceMixRite is the most simple injector to use. Less maintenance is required and no technician is needed for changing spare parts.
MixRite Range
TF - 252.5 TF - 5 TF - 103.5
Recommended standard Installation inline1. Main Valve2. Back flow preventor3. Pressure regulator4. Filter - 130 Micron Min. (130 mesh)5. Manometer (pressure gauge)6. Anti siphon Valve7. Operation Valve
1
Simplicity by design
Simple installationMixRite is a "Plug and Play" unit. Installation of MixRite can be done by using the instructions which are attached to each unit.
DOSING PUMPS
6 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
Ø143.60 (5.6")
94 (3
.7")
L
1 m3/h
Application Color Code
Application Sleeve Color TEFEN Code Seal MaterialSpring
Material
Domestic Landscaping (0.2% fix) STD NBR SST
Chlorine / Industry CL Viton Hastelloy
Technical InformationWater pressure 0.2 – 8 bar (2.9 – 120 psi)Flow Rate 20 – 1000 l/h (5.29 – 264.5 gal/h)Working temp 4-40˚ C (39.2-104˚ F)Coupling 3/4”
Model LFix 212.5 (8.3")
Adjustable 254.0 (10")
1 Series
DOSING PUMPS | 7
Dosage Rate % Flow Rate Range Pressure Range Connectors Dia.Thread
Min-Max Injection
Rate Per HourApplications
0.2% Fix 20 - 1000 l/h 0.2 - 8 bar 3/4" BSPT 0.04 - 2 l/h Landscaping
0.1% - 1% 20 - 1000 l/h 0.2 - 8 bar 3/4" BSPT 0.02 - 10 l/h Landscaping / Chlorine / Industry
0.2% - 2% 20 - 1000 l/h 0.2 - 8 bar 3/4" BSPT 0.04 - 20 l/h Landscaping / Chlorine / Industry
0.4% - 4% 20 - 1000 l/h 0.2 - 8 bar 3/4" BSPT 0.08- 40 l/h Landscaping / Chlorine / Industry
Pressure Loss
Fixed1%2%4%
Max. injection rate/h
0.2% 1.0% 2.0% 4.0%
Injection RateL/h gph
12
10
8
6
4
2
0
45
40
35
30
25
20
15
10
5
0
Application Range
psi bar
17.3 1.2
14.4 1
11.6 0.8
8.7 0.6
5.8 0.4
2.9 0.2
0
Flow Rate (l/h)
20 100 500 1000
DOSING PUMPS
8 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
160(6.3")
219(
8.62
")
L
A
A
L (Height) On/Off Air Release
Max. 528 (20.7") 496 (19.5")Min. 497 (19.5") 457 (17.9")
Internal bypass *Yellow sleeve
External bypass*Yellow sleeve
By Pass models
Water pressure 0.2 – 8 bar (2.9 – 120 psi)Flow Rate 7 – 2500 l/h (1.85 – 660 ) gal/hWorking temp 4-40˚ C (39.2-104˚ F)Coupling 3/4”
2.5 Series | Low Flow RateAvailable options Technical Information
Application Color Code
Application Sleeve Color TEFEN Code Seal MaterialSpring
Material
Irrigation STD NBR SST
Livestock PO NBR, EPDM SST, Hastelloy
Acids PVDF AFLAS Hastelloy
Chlorine CL Viton Hastelloy
Industry C EPDM, AFLAS SST, Hastelloy
Car Wash CW AFLAS SST, Hastelloy
Landscaping STD NBR SST
By-Pass I / B EPDM, AFLAS SST, Hastelloy
ElectricON/OFF
HydraulicON/OFF
ManualON/OFF
2.5 m3/h
DOSING PUMPS | 9
Application Range
Dosage Rate % Flow Rate Range
Pressure Range
Connectors Dia. Thread
Min-Max Injection Rate Per
Hour
ApplicationsGross
weight std unit
0.2% fix 7 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.014 - 5 l/h Landscaping 1.4 KG
0.8% fix 7 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.056 - 20 l/h Landscaping / Irrigation / Livestock 1.5 KG
1% fix 7 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.07 - 25 l/h Landscaping / Irrigation / Livestock 1.8 KG
2% fix 7 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.14 - 50 l/h Acid 2.7 KG
0.1% - 0.9% 7 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.007 - 22.5 l/h Irrigation / Livestock / Chlorine / Car Wash / Acid 1.8 KG
0.3% - 2% 7 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.021 - 50 l/h Irrigation/Livestock / Chlorine / Car Wash / Industry / Acid 1.8 KG
0.4% - 4% 7 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.028 - 100 l/h Irrigation/Livestock / Chlorine / Car Wash / Industry / Acid 1.8 KG
0.3% - 2% bypass 20 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.06 - 50 l/h Irrigation / Livestock /
Chlorine / Acid 1.9 KG
0.4% - 4% bypass 20 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.08 - 100 l/h Irrigation / Livestock / Chlorine /Acid 1.9 KG
0.3% - 2% Internal bypass 20 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.06 - 50 l/h Irrigation / Livestock /
Chlorine /Acid 1.9 KG
0.4% - 4% Internal bypass 20 - 2500 l/h 0.2 - 8 bar 3/4” BSPT 0.08 - 100 l/h Irrigation / Livestock /
Chlorine /Acid 1.9 KG
Pressure Loss Max. injection rate/h
bar psi
1.80 26.1
1.60 23.2
1.40 20.3
1.20 17.4
1.00 14.5
0.80 11.6
0.60 8.7
0.40 5.8
0.20 2.9
0.00 0.00
4% 2%
0.2% Fix
7 20 100 500 1000 1500 2500 l/h 0.2% Fix 0.1 -0.9% 0.3-2% 0.4-4%
Injection RateL/h gph
300 79
200 53
100 26
0 0
DOSING PUMPS
10 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
L (Height) On/Off Air Release
Max. 551 (21.7") 486 (19.1")Min. 471 (18.5") 447 (17.6")
160 (6.3")
219
(8.6
2")
L
A
A
Internal bypass *Yellow sleeve
External bypass*Yellow sleeve
By Pass models
3.5 Series | Low Flow RateTechnical Information
Water pressure 0.2 – 8 bar (2.9 – 120 psi)Flow Rate 10 – 3500 l/h (2.65 – 930 ) gal/hWorking temp 4-40˚ C (39.2-104˚ F)Coupling 3/4”
ElectricON/OFF
HydraulicON/OFF
ManualON/OFF
Application Color Code
Application Sleeve Color TEFEN Code Seal MaterialSpring
Material
Irrigation STD NBR SST
Livestock PO NBR, EPDM SST, Hastelloy
Acids PVDF AFLAS Hastelloy
Chlorine CL Viton Hastelloy
Industry C EPDM, AFLAS SST, Hastelloy
Car Wash CW AFLAS SST, Hastelloy
Landscaping STD NBR SST
By-Pass I / B EPDM, AFLAS SST, Hastelloy
Available options
3.5 m3/h
DOSING PUMPS | 11
Application Range
Dosage Rate % Flow Rate Range
Pressure Range
Connectors Dia. Thread
Min-Max Injection
Rate Per HourApplications
Gross weight std
unit
0.03% - 0.2% 10-3500 l/h 0.2 - 8 bar 3/4” BSPT 0.003 -7 l/h Chlorine / Car Wash 1.9 KG
0.1% - 0.9% 10-3500 l/h 0.2 - 8 bar 3/4” BSPT 0.01 -31.5 l/h Irrigation / Chlorine / Car Wash / Acid 1.9 KG
0.3% - 2% 10-3500 l/h 0.2 - 8 bar 3/4” BSPT 0.03 - 70 l/h Irrigation / Livestock / Industry / Chlorine / Acid 1.9 KG
0.5% - 5% 10-3500 l/h 0.2 - 8 bar 3/4” BSPT 0.05 - 175 l/h Irrigation / Livestock / Industry / Chlorine / Acid 1.9 KG
1% - 10% 10-3500 l/h 0.2 - 8 bar 3/4” BSPT 0.5 - 350 l/h Industry / Chlorine / Car Wash / Acid 1.9 KG
1% - 10% I.B.P 50-3500 l/h 0.2 - 8 bar 3/4” BSPT 0.5 - 350 l/h Irrigation / Livestock / Chlorine / Acid 3.0 KG
Pressure Loss
10%5%2%
10 20 1500 2000 3500 l/h
bar psi
32.82.62.42.2
2.00 29.01.80 26.11.60 23.21.40 20.31.20 17.41.00 14.50.80 11.60.60 8.70.40 5.80.20 2.90.00 0.00
0.2% Fix 0.1-0.9% 0.3-2% 0.4-4% 3-10%
Injection RateL/h gph
350 92
200 53
100 26
0 0
Max. injection rate/h
DOSING PUMPS
12 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
218 (8.6”)
291 (
11.5”
)
531 (
2.09
”)
ø174 (6.8”)
L (Height) On/Off Air Release
Max. 680 (26.7") 595 (23.4")Min. 585 (23") 545 (21.4")
TF-5 | Low Flow RateAvailable models Technical Information
Water pressure 1 - 8 bar (14.7 - 120 PSI)Flow Rate 0.05 - 5 m3/h (0.2 - 22 GPM)Working temp 4-40˚ C (39.2-104˚ F)Coupling 1” or 32 mm* Legs available upon special request
Application Color Code
Application Sleeve Color TEFEN Code Seal MaterialSpring
Material
Irrigation NBR SST, Hastelloy
Livestock PO EPDM SST, Hastelloy
Chlorine CL Viton Hastelloy
ElectricON/OFF
HydraulicON/OFF
ManualON/OFF
5 m3/h
DOSING PUMPS | 13
Application Range
Pressure Loss
Dosage Rate % Flow Rate Range
Pressure Range
Connectors Dia. Thread
Min-Max Injection
Rate Per HourApplications
Gross weight std unit
0.1% - 1% 0.05 - 5 m³/h 1 - 8 bar 1" BSPT/NPT 0.05 - 50 l/h Irrigation / Chlorine / Livestock 5 KG
0.2% - 2% 0.05 - 5 m³/h 1 - 8 bar 1" BSPT/NPT 0.25 - 250 l/h Irrigation / Chlorine / Livestock 5 KG
0.5% - 5% 0.05 - 5 m³/h 1 - 8 bar 1" BSPT/NPT 0.1 - 250 l/h Irrigation / Chlorine / Livestock 5 KG
bar psi1.00 14.5
0.80 11.6
0.60 8.7
0.40 5.8
0.20 2.9
0.00 0.00200 500 1000 2000 3000 4000 5000 l/h0.88 2.2 4.4 8.8 13.2 17.6 22.0 gpm
TF-5 005TF-5 002TF-5 001
TF5 - 001 TF5 - 002 TF5 - 005
Injection RateL/h gph
300 79
200 53
100 26
0 0
Max. injection rate/h
DOSING PUMPS
14 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
250 (9.8”)
337
(13.3
”)
618
(2.4
.3”)
ø208 (8.1”)
L (Height) On/Off Air Release
Max. 760 (29.9") 660 (26")Min. 720 (28.34") 625 (24.6")
TF-10 | Low Flow RateTechnical Information
Water pressure 1 - 8 bar (14.7 - 120 PSI) Flow Rate 0.05 - 10 m3/h (0.2 - 45 GPM)Working temp 4-40˚ C (39.2-104˚ F)Coupling 1.5” or 50 mm* Legs available upon special request
Available options
ElectricON/OFF
HydraulicON/OFF
ManualON/OFF
10 m3/h
Application Color Code
Application Sleeve Color TEFEN Code Seal MaterialSpring
Material
Irrigation NBR SST, Hastelloy
Chlorine CL Viton Hastelloy
DOSING PUMPS | 15
Application Range
Dosage Rate % Flow Rate Range
Pressure Range
Connectors Dia. Thread
Min-Max Injection Rate Per
Hour
Applications Gross weight std unit
0.1% - 1% 0.05 - 10 m³/h 1 - 8 bar 11/2" BSPT 0.05 - 100 l/h Irrigation / Chlorine / Livestock 7.3 KG
0.2% - 2% 0.05 - 10 m³/h 1 - 8 bar 11/2" BSPT 0.1 - 200 l/h Irrigation / Chlorine / Livestock 7.3 KG
1% - 5% 0.05 - 10 m³/h 1 - 8 bar 11/2" BSPT 0.5 - 500 l/h Irrigation / Chlorine / Livestock 7.3 KG
Pressure Loss
500 2000 4000 6000 8000 10000 l/h4.4 8.8 17.6 26.4 35.2 44.0 gpm
bar psi0.90 13.23
0.80 11.60
0.70 10.15
0.60 8.70
0.50 7.25
0.40 5.80
0.30 4.35
0.20 2.9
0.10 1.45
0.00 0.00
TF-10 005TF-10 002TF-10 001
TF10 - 001 TF10 - 002 TF10 - 005
Injection RateL/h gph
500 132
400 106
300 79
200 53
100 26
0 0
Max. injection rate/h
DOSING PUMPS
16 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
TF-25 | Low Flow RateTechnical Information
Water pressure 1 - 8 bar (14.7 - 120 PSI)Flow Rate 0.2 - 25 m3/h (9-110 GPM)Working temp 4-40˚ C (39.2-104˚ F)Coupling 2” or 63 mm* Legs - Standard supply
340 (13.3”)
~132
8 (5
2.2”
)
~650 (25.6”)
865
(34”
)
855+
100
(33.
6”+3
.9”)
L (Height) On/Off Air Release
Max. 1030 (40.5") 1000 (39.3")Min. 880 (34.6") 900 (35.4")
Available options
Application Color Code
Application Sleeve Color TEFEN Code Seal MaterialSpring
Material
Irrigation NBR SST, Hastelloy
Chlorine CL Viton Hastelloy
ElectricON/OFF
HydraulicON/OFF
ManualON/OFF
25 m3/h
DOSING PUMPS | 17
Application Range
Dosage Rate % Flow Rate Range
Pressure Range
Connectors Dia. Thread
Min-Max Injection Rate Per
Hour
Applications Gross weight std unit
0.1% - 1% 0.2 - 25 m³/h 1 - 8 bar 2" BSPT 0.2 - 250 l/h Irrigation / Chlorine / Livestock 18.5 KG
0.3% - 2.5% 0.2 - 25 m³/h 1 - 8 bar 2" BSPT 0.6 - 625 l/h Irrigation / Chlorine / Livestock 18.5 KG
1% - 5.5% 0.2 - 25 m³/h 1 - 8 bar 2" BSPT 2.0 - 1375 l/h Irrigation / Chlorine / Livestock 18.5 KG
Pressure Loss
bar psi1.60 23.2
1.40 20.3
1.20 17.4
1.00 14.5
0.80 11.6
0.60 8.7
0.40 5.8
0.20 2.9
0.00 0.00
TF-25 005TF-25 002TF-25 001
1000 3000 4000 5000 10000 15000 20000 25000 l/h4.4 13.2 17.6 22.0 44.0 66.0 88.0 110.0 gpm TF25 - 001 TF25 - 002 TF25 - 005
Injection RateL/h gph
1300 344
1200 317
1100 291
100 264
900 238
800 212
700 185
600 159
500 132
400 106300 79
200 53
100 26
0 0
Max. injection rate/h
DOSING PUMPS
18 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
Proportional and Automatic Bypass SystemThe TreatRite™ system provides a proportional method between the mainline (A) and the sub-mainline (B), supported by a sophisticated innovative hydraulic system. The MixRite™ pump is a volumetric, proportional unit. The combination between the MixRite™ Dosing Pump and the By-Pass unit creates a fully proportional dosing system. This concept provides its user a perfect solution for water treatment. The end user of the TreatRite™ system can dose common additives for water treatment, such as: Sodium Hypochlorite, Chlorine Dioxide, and Hydrogen Peroxide. The TreatRite™ system can be operated in various ranges as shown:
- Water Treatment Line
Pressure Loss VS. Flow Rate
5.00.00
0.40
0.80
1.20
1.60
15.0 25.0 35.0 45.0 55.0 65.0 75.0 85.0 95.0
Pres
sure
Los
s (b
ar)
Mainline Flow Rate (m3/h) 2" 3" 4"
TreatRite
DOSING PUMPS | 19
Flow Rangem3/h (GPM)
Dosage Range A B C
(%) L/h (GPM)
6-25 (26-110) 0.003-1 0.18-250(0.0008-1.1) 2'' 3/4'' 2.5/3.5
15-50 (66-220) 0.01-0.5 1.5-250(0.0066-1.1) 3'' 1'' TF5
30-100 (122-440) 0.01-0.5 3-500(0.0132-2.2) 4'' 1 1/2'' TF10
range:
Operating Principle: ■ The pilot operating valve samples the pressure level
at multiple points, and controls the opening condition of the diaphragm.
■ This operation governs the flow rates to generate a stable 1:10 ratio between lines.
Case Study (Water Treatment) ■ Total water flow rate: 67.3 m3/h ■ Desired dosage rate: 0.1% ■ Additive amount: 67.3 x 0.1% = 0.0673 m3/h ■ Relevant configuration: 4’’, 1.5" ■ Main line water flow: 67.3 x 0.9 = 60.57 m3/h ■ By-Pass water flow: 67.3 x 0.1 = 6.73 m3/h ■ Relevant injector: TF10 0.2%-2% ■ Dosage setting on injector: 0.0673 / 6.73 = 1%
Features and Benefits ■ Keeps constant proportional flow rate ■ Hydraulic, Volumetric and non-electric ■ Dosing proportional to flowrate ■ Precision: surface quality optimized with no waste ■ Flow rate between main line and sub-main line will
remain 10:1 at wide flow rates ■ Working pressure up to 8 bar (116 PSI) ■ High UV resistance ■ High chemical resistance ■ Supplied pre - set. No need for calibration ■ Excellent dosing repeatability and homogeneity ■ Easy to install, operate and maintain, with no
electricity risk
TF-52.5 3.5 TF-10
DOSING PUMPS
20 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
2
4
5
6
7
6
1 2
3
Main Water pipe
1 23
4 9
8
5 6 7
Available optionTefen’s Mixrite offers pumps for a variety of applications such as: cost effecting fertilizing, adding medication for livestock, cleaning or disinfecting fluid lines, car washing, sanitizing water systems and more. MixRite offers a wide range of sizes and flow rates, and can be installed in a broad array of system configurations, besides being put.
Typical bypass installation when using large fertilizer tanks1. Main Valve2. Filter - Ø 3/4”-130 Micron Min.3. Pressure regulator4. Choking Valve5. PVC fertilizer Valve6. Fertilizer Filter7. Normally closed hydraulic Fertilizer Valve 8. Fertilizer solution tank9. 5/16” command tube
Typical plumbing control for Livestock application 1. Pressure regulator2. Pressure Gauge3. Check Valve4. Water filter - 120 mesh minimum5. Water Meter with Pulse6. Bypass valve7. MixRite Medicator
Typical installation
DOSING PUMPS | 21
1 2
3
4
Main Water pipe
LDPE Tube Ø 25 mm
1
2
3
4
A Combination of main filtration station and MixRite TF injector on a bypass installation.1. Main Valve2. Chocking Valve3. MixRite TF Injector4. 2” Bypass line
1
2
3
4
5
A Typical Bypass array installation for three MixRite TF model injectors1. Main water valve2. Main water filter3. Chocking Valve4. Fertilizer Solution Filter5. Mixing chamber (Empty filter)
Bypass plastic piping installationwith 4 different additives1. Main Valve2. Filter - 130 Micron Minimum3. Chocking Valve4. Fertilizer filter
DOSING PUMPS
22 | TECNOLOGÍA DE FLUJO Y DOSIFICACIÓN
1
2
3
A typical bypass installation for a single MixRite TF injector.1. Chocking Valve2. MixRite TF Injector3. Fertilizer Reservoir Tank
A typical double inline installation for MixRite TF models
Typical installation
DOSING PUMPS | 23
3/4” FlowGuardCat. No. 38220000002
3/4” StaticPressure regulatorCat. No. 38030200001
3/4” Antisiphon kitCat. No. 36073008002
Manual ON/OFFOption
Suction foot valveCat. No. 38005728104
3/4” Water FilterCat. No. 38000000172
3/4” Backflow preventor Cat. No. 38030200004
Hydraulic remote control ON/OFFOption
3/4” PressureRegulatorCat. No. 38030200002
3/4” FertiguardCat. No. 38220000001
Stainless Steel Wall mounting BracketCat No. 35000000010For models TF25
Plastic wall mounting bracket and stand basecat no. 36030162765For MixRite TF5 & TF10 models
Electric remotecontrol ON/OFFOption
Plastic Wall mounting bracketcat no. 36030162765For all “3/4 MixRite models
3/4” hydraulic Normally Closed valveCat. No. 38000000011
Accessories
TEFEN LTD. Kibbutz Nahsholim 3081500 Israel | Tel. 972 4 6395944 | Fax. 972 4 6390813 | [email protected] | www.tefentech.com
ED
ITIO
N 0
4 EN
09/
19 n
ow-b
rand
ing.
co.il
For the removal of any doubt, this documents does not constitute an offer on the part of Tefen and/or any undertaking on its part. Tefen may change the content of this document and/or the technical specifications of the products and/or add and/or remove products and/or change prices and/or any terms and conditions specified in this document at any time and upon its sole discretion without any prior notice.