DIVOM Methodology using RAMONA5-FA Code

Presentation to theAdvisory Committee on Reactor Safeguards

January 2011

AARE VA

Page 3: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Presentation Objective and Scope

Objective: Support the staff review findings and recommendation toremove the 10% penalty on DIVOM slope calculated by RAMONA5-FA forextended flow control window operation

Scope: Condensed version of the Nov. 17, 2010 presentation to thesubcommittee on power uprates and responsive to its feedback

" Overview of BWROG and AREVA Detect & Suppress Stability Solution

" Addressing the ACRS and Staff Concerns" Quantification of HCOM multiplier for MELLLA+ was not clear" Effect of bypass boiling on the loss of calibration of the LPRMs" Unexplained behavior of the dryout/rewet experimental results" RAMONA5-FA code system had not yet undergone a staff review

F I0 Dispositioning ACRS and Staff Concerns

" Clarify the HCOM multiplier role" Confirm OPRM detector undamped performance under bypass boiling" Explain experimental results on cyclical dryout and updated evaluation" NRC audit review of numericallphysical models and closing relations confirm

RAMONA5-FA applicability for DIVOM calculations

ration toteACRS on RAMONA5-FA DIVOM Methodoloav - Januarv 2011 - D.3 !•EVAPre~An1Presenation to the ACRS on RAMONA5-FA DIVOM Methodoloav - Januarv 2011 - D.3

Page 4: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Overview of BWROG Option III Solution

Io Detect & Suppress

Oo Scram to Protect CPR Safety Limit

LPRMsignals

OPRMsignal

III IYES

4YES

SCRAM

NO I NO ýA

AR EVAPresentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.4

Page 5: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Option III Stability SolutionOriginal BWROG vs. AREVA Enhanced

DIVOM HCOM OPRM Signal

SLMCPR Conservativ Scram Setpoint

statisticalCPR analysis 4

Response O M vs . Sotpolnt

Oscillation Magnitude

lo OPRM System: same

0 HCOM Analysis: Revised for MELLLA+ application

Perform new analysis reflecting core loading and stability, orPreferred option to use existing analysis and apply 5% conservative penalty

* Assessed by consideration of higher MELLLA+ oscillation growth ratio* Not taking credit for single channel instability exclusion that limits growth ratios* Not taking credit for flatter power shape

0 DIVOM: same numerical methods (using RAMONA5-FA), plus

No ill-defined DIVOM correlation due to single channel instability

Il Operating Domain: RevisedSingle channel instability exclusion region protected by hard scram

APresentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.5 AR EVA

Page 6: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Applicability Domain of Option III SolutionsOriginal BWROG versus AREVA EnhancedO Armed region where instabilities are possible

l BWROG is qualified for current operating domains including power uprate,but not for MELLLA+ extended flow window operation

0' AREVA Enhanced solution introduces the single channel instabilityexclusion region protected by scram

Well-behaved DIVOM calculation guaranteed

Extended applicability to MELLLA+

0 0 Channel Instability / ,f

o0 Exclusion Region -

LI.

n, Ar-med Region R,, A

/• ""••°Original BWROG .•AREVA Enhanced

Core Flow Core Flow APresentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.6 A REVA

Page 7: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Option-Ill Stability Solution is Conservative .

oo Significant conservatism in the methodologyK Analysis for the Hot Channel Oscillation Magnitude (HCOM) is conservative

* Calculates a statistical 95/95 value0 Conservatively assumes the most responsive OPRM signal fails

0 Protection of the SLMCPR* Event is cyclic with a frequency shorter than the fuel rod time constant* In case of dryout, clad will rewet within a fraction of the oscillation period

Po Inherent DIVOM conservatismsK A single DIVOM run is a best estimate calculation, however, procedure calls for several

calculations at different exposures and varied power and flow points and the mostconservative slope is used

" DIVOM is based on regional mode oscillations where its slope is - twice the globalmode slope

K RAMONA5-FA produced DIVOM calculations are robust where the DIVOM curve slopesare generally similar to the original generic slope. Conditions that make DIVOM ill-defined are not allowed.

10 Caution against excessive conservatism0 Example: Peach Bottom Unit 3 (Feb. 11, 2005)

* Trip signal received, but OPRM system not yet armed* No other indication of oscillations* Attributed to overly conservative OPRM setpoint

APresentation to the ACRS on RAMONA5-FA DIVOM Methodoloav - January 2011 - o.7 -ARIEVA

Page 8: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Bypass Boiling Effect on LPRM Sensitivity

Facts:" Boiling in the bypass is possible at natural circulation

" LPRM loss of calibration -- response is reduced due to loss of neutronmoderation in bypass

Concern:K0 Direct energy deposition leads to dynamic oscillatory bypass boiling

0 High void fraction at power peak reduces detector response, and vice versa-4 underestimated peak-to-peak oscillation magnitude

Disposition:

Presentation to the ACRS on RAMONA5-FA DIVOM Methodoloav - Januarv 2011 - D.8 AREVA

Page 9: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Bypass Boiling EffectSimulation of a bypass channel driven by an oscillating power function

AAýRE-VA-Presentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.9

Page 10: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Bypass Boiling EffectOPRM normalized signal is unaffected by loss of LPRM calibration

APresentation to the ACRS on RAMONAS-FA DIVOM Methodology- January 2011 -p.10

Page 11: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Bypass Boiling Effect

AkR•EVA•Presentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.11

Page 12: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Experimental Data on Cyclical Dryout

Background:* Experimental data were presented showing rod temperature response to

flow oscillations in a full scale test bundle (KATHY)

* Measured oscillating inlet mass flow rate used to drive RAMONA5-FA andcalculate CPR response

* Calculated CPR<1 was shown to "generally" correspond to rising rodtemperature

Presentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.12

A¸ -A

Page 13: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Experimental Data on Cyclical Drvout

AA.RE-VA.Presentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.13

Page 14: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Experimental Data on Cyclical Drvout.-.

An to the ACRS on RAMONA5-FA DIVOM Methodoloav - January 2011 - D.14 ARE-VA,Presentatio

Presentatio

Page 15: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Experimental Data on Cyclical Drvout

'A'AR EVAPresentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.15

Page 16: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Experimental Data on Cvclical Drvout

Presentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.16 ARIEVA,

Page 17: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

RAMONA5-FA Audit Review ,' .

Auditors (staff and consultants) visited AREVA offices inRichland (Sept. 2008)

Full access to code source and documentation provided byAREVA staff and consultants

Test cases designed to stress the code were performed on site

Test cases involving source code modifications to introduceartificial biases for testing sensitivities were also performed onsite

Timely responses were provided by AREVA to a follow up set ofRAI questions

Draft SER acknowledges the adequacy of RAMONA5-FA forDIVOM calculations and removes the interim penalty of 10% onits slope which was- imposed on extended flow windowapplications pending the audit review

ARPreentation to the ACRS on RAMONA5-FA DIVOM Methodoloav - January 2011 - D.17 !R !E•VA

Page 18: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

RAMONA5-FA Audit Reviewf

Examples of audit review and RAI test cases

K Comparison of quasi steady-state perturbations to MICROBURN-B2

* Pressure" Subcooling* Control rod position perturbation

K> With the exception of control rod position, all nodal and modal neutronkinetics methods showed good performance compared withMICROBURN-B2

" Nodal methods performed well in the control rod perturbation cases" Modal method was successfully demonstrated to lose accuracy for localized

perturbations (control rod movement) due to low order modal expansion0 Provided validation information for various models

* Validation of the decay heat model* Comparison of pressure drop data to MICROBURN-B2 and steady-state and

transient test data* Justification of the direct energy deposition models* Benchmarking calculations of subcooled boiling models

APresentation to the ACRS on RAMONAS-FA DIVOM Methodology - January 2011 - p.18 AR E-V•A

Page 19: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Minimal DIVOM Sensitivity toVarying Void-Quality Correlations

ýAARE VAPresentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.19

Page 20: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

LI

-jAPresentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.20

Page 21: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

L

Im

Presentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.21

Page 22: DIVOM Methodology Using RAMONA5-FA Code, Presentation …Presentation Objective and Scope Objective: Support the staff review findings and recommendation to remove the 10% penalty

Closing Remarks

AREVA has addressed all concerns and requests foradditional information regarding its RAMONA5-FA basedDIVOM curve methodology

DIVOM slope change of the order of 10% could be affectedonly with unreasonable model biases

No phenomena associated with extended flow windowoperation were found such that DIVOM slope is impacted

Rescinding the interim 10% penalty on DIVOM slope forextended flow window applications as recommended by thedraft SER is greatly appreciated

APresentation to the ACRS on RAMONA5-FA DIVOM Methodology - January 2011 - p.22 A!R E:.VA