  • Directional Control Valves

    Photo Type Series Description Main Specifications

    SolenoidValves SS Solenoid Valve 26.4 - 42.3gpm, 5000psi

    SolenoidValves SA

    Solenoid Valve (DINConnector Type) 26.4 - 42.3gpm, 5000psi

    SolenoidValves SE

    Solenoid Valve (LowCurrent & Low PowerConsumption Type)

    7.9 - 26.4gpm 1428 - 3000psi

    SolenoidValves

    DSS (DSA)

    Solenoid ControlledPilot Operated Valve 158.5gpm, 4571psi

    FineSolenoidValves

    SF Fine Solenoid Valve(High-Low Valve) 2.6 - 10.6gpm, 3000psi

    SolenoidValves SAW

    Solenoid Valve withMonitoring Switch 42.2gpm, 5076psi

    ManualValves DMA

    Manually OperatedDirectional Valve 10.6 - 19.8gpm, 3571psi

  • S-1

    WET TYPE SOLENOID OPERATEDDIRECTIONAL CONTROL VALVE

    SS Series (Wiring System: Central Terminal Box)Wet Type Solenoid Valve

    26.4 to 42.3gpm5000psi

    Features

    Specifications

    qVery long lifeThe movable iron core of the wet type sole-noid is immersed in oil, which keeps it lubri-cated and cushions it from impact and vibra-tion, ensuring very long life.

    wLow switching noiseThe wet-type solenoid valve provides verylow core switching noise, for quiet operation.

    eHigh pressure, large capacity, with minimalpressure lossComprehensive fluid reaction force compen-

    sation and low pressure compensation con-struction provide large capacity and lowpressure loss. G01 : 35MPa{357kgf/cm2}100r/minG03 : 35MPa{357kgf/cm2}160r/min

    rEasy connectionsA special wiring box provides a COM portand indicator light as standard for simplewiring and maintenance.

    tEasy coil replacementA plug-in type coil enables one-touch coil

    replacement. yWide-ranging backward compatibility makes

    it simple to replace previous valve modelswith this one. Combining this valve with amodular valve contributes to the compactconfiguration of the overall device.

    uGlobal support (G01 size)Meets overseas safety standards (CE, UL,and CSA). It can be safely used anywhere inthe world. Contact your agent for certifiedproducts.

    Note) The maximum flow rate of each valve depends on the pressure. For details, see pages S-9 and S-10.

    Model No.

    SS-G01 SS-G03

    Standard Type Shockless TypeStandard Type

    Shockless TypeAC Solenoid Type DC Solenoid Type(With built-in rectifier)

    JIS Symbol OperationSymbolMaximumFlow Rater/min

    Maximum WorkingPressure

    MPa{kgf/cm2}

    MaximumFlow Rater/min

    Maximum WorkingPressure

    MPa{kgf/cm2}

    MaximumFlow Rater/min

    Maximum WorkingPressure

    MPa{kgf/cm2}

    MaximumFlow Rater/min

    Maximum WorkingPressure

    MPa{kgf/cm2}

    MaximumFlow Rater/min

    Maximum WorkingPressure

    MPa{kgf/cm2}-A2X- (gpm)

    30(7.9)

    35(5000)

    (gpm)

    30(7.9)

    25{255}(3571)

    40(10.6)

    35{357}(5000)

    85(22.4)

    35{357}(5000)

    85(22.4)

    25{255}(35.71)

    -H2X-

    (psi)

    -E2X- 85(22.4)-A3X- 80

    (21.1)

    50(13.2)

    130(34.3)

    160(42.2)

    130(34.3)

    -H3X-

    -E3X- 100(26.4)-A3Z-

    65(17.1)-H3Z-

    -E3Z-

    -A4- 50(13.2)

    -H4-

    -A5-

    100(26.4)

    -H5-

    -C2-

    -C5-

    -C9-

    -C1S-

    -C6S-

    -C1- AC Solenoid65 (17.1)DC Solenoid80 (21.1)-C6-

    -C4-

    50(13.2)-C7Y- 40

    (10.6)70

    (18.5)25{255}(3571)

    100(26.4)

    25{255}(3571)

    85(22.4)

    -C8-

    (psi) (psi) (psi) (psi)(gpm) (gpm) (gpm)

    05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 1

  • S-2

    SS-G01 SS-G03

    AC SolenoidDC Solenoid

    AC SolenoidDC Solenoid

    Built-in Rectifier Built-in Rectifier

    C* E* D* C* E* D*MaximumWorkingPressure

    35(25)MPa{357(255)kgf/cm2}(Note1) (5000psi)

    MaximumAllowable

    BackpressureT port 21MPa{214kgf/cm2} (3000psi) 16MPa{163kgf/cm2} (2285psi)

    Switches/min.Standard Type 300

    120300 300

    120240

    Shockless Type 120 120Standard Indicator light R R

    Opt

    ion

    Shockless F FSurgeless G G G G

    With manual push-button N NQuick Return Q Q

    Weight(kg)

    Double Solenoid 1.8 2.0 4.2 5.5Single Solenoid 1.4 1.5 3.5 4.1

    Ope

    ratin

    gEn

    viro

    nmen

    t

    Dust Resistance/Water Resistance Rank JIS C 0920 IP64 (Dust-tight, Splash-proof)Ambient Temperature 20 to 50C

    Ope

    ratin

    gFl

    uid

    Temperature Range 20 to 70C

    Viscosity Range 15 to 300mm2/sFiltration 25 microns or less

    Mou

    ntin

    g bo

    lt M5 45 (Four)1024 1 3/4

    M6 70 (Four) (M8 70 (Four)) 1/420 2 3/4

    M5 5 to 7N.m{51 to 71kgf.cm}1024 3.65.1Lbs.ft.

    M6 10 to 13N.m{102 to 133kgf.cm}(M8 20 to 25N.m{204 to 255kgf.cm})

    1/420 7.29.4Lbf.ft.

    Note) 1. Maximum operating pressure depends on the valve type. For details, see page S-1. 2. For mounting bolts, use 12T or equivalent.

    zPipe system so that tank line isalways filled with oil.

    xSurge pressure should be keptbelow maximum tank line backpressure rating.

    cWhen using a 4-way valve as a 2-way or 3-way and blocking unusedports lowers the maximum flow.

    vKeep hydraulic oil clean. (Degree ofcontamination: NAS grade 12 orbetter). When petroleum hydaulicoil is used, it should conform to ISOVG32, 46.

    bDo not exceed permissible voltagerange of the coil used.

    nDo not supply electric power to theAC solenoid unless the coil ismounted to the valve.

    mProvide drain piping from the Tport, when valve spool types areA2X, H2X, E2X.

    ,If the changeover position is keptunder high pressure for an extend-ed period, malfunctions may occurdue to hydraulic lock. Please con-sult us when you have such appli-cation.

    .When the detent-type (E2X, E3X,E3Z) is used, we recommend thatthe electric power supply be contin-

    uous in order that the changeoverposition may be firmly maintained.

    0Resistance force against the manu-al override pin changes, dependingon the back pressure of the tankline.

    1Solenoid coil could be hot by con-tinuous operation. Do not touch thecoil directly by hand.

    2Gasket dimensionSA/SS-G01 = ISO 4401-03-02-0-94SA/SS-G03 = ISO 4401-05-04-0-94

    P, A, B ports

    Size Length

    Tightening Torque

    Notes

    05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 2

  • S-3

    Solen

    oidTy

    pe

    PowerSupplyType

    Voltage(V)

    Frequency(Hz)

    For SS-G01 For SS-G03Solenoid Coil

    TypeDrive Current

    (A)Holding Current

    (A)Holding Power

    (W)Allowable

    Voltage Range(V)Solenoid Coil

    TypeDrive Current

    (A)Holding Current

    (A)Holding Power

    (W)Allowable

    Voltage Range(V)

    AC

    C1AC100

    50

    EDC64-C1

    2.2 0.52 25 80 to 110

    ECB64-C1

    5.4 0.92 36.0 80 to 110

    60 2.0 0.38 2290 to 120

    4.6 0.62 34.090 to 120

    AC110 60 2.2 0.46 28 5.0 0.78 42.0

    C115AC110

    50

    EDC64-C115

    2.0 0.47 25 90 to 120

    ECB64-C115

    5.0 0.85 36.0 90 to 120

    60 1.8 0.35 22100 to 130

    4.2 0.57 34.0100 to 130

    AC115 60 2.0 0.42 28 4.6 0.72 42.0

    C2AC200

    50

    EDC64-C2

    1.1 0.26 25 160 to 220

    ECB64-C2

    2.7 0.46 36.0 160 to 220

    60 1.0 0.19 22180 to 240

    2.3 0.31 34.0180 to 240

    AC220 60 1.1 0.23 28 2.5 0.39 42.0

    C230AC220

    50

    EDC64-C230

    1.0 0.24 25 180 to 240

    ECB64-C230

    2.5 0.42 36.0 180 to 240

    60 0.91 0.17 22200 to 260

    2.1 0.29 34.0200 to 260

    AC230 60 1.0 0.21 28 2.3 0.36 42.0

    DC w

    ith B

    uilt-i

    n Re

    ctifie

    r E1 AC100 50/60 EDC64-E1-1A 0.37 27 90 to 110 ECB64-E1 0.40 34.0 90 to 110

    E115AC110

    50/60 EDC64-E115-1A0.26 25

    100 to 125 ECB64-E1150.33 31.0

    100 to 125AC115 0.27 27 0.34 34.0

    E2 AC200 50/60 EDC64-E2-1A 0.15 26 180 to 220 ECB64-E2 0.22 37.0 180 to 220

    E230AC220

    50/60 EDC64-E230-1A0.12 24

    200 to 250 ECB64-E2300.16 30.0

    200 to 250AC230 0.13 27 0.17 33.0

    DC

    D1 DC12 EDC64-D1-1A 2.2 26 10.8 to 13.2 ECB64-D1 2.6 31.0 10.8 to 13.2

    D2 DC24 EDC64-D2-1A 1.1 26 21.6 to 26.4 ECB64-D2 1.5 36.0 21.6 to 26.4

    Solenoid Assembly Specifications

    Understanding Model NumbersJ21 C2 R X 3 A 03 G SS

    05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 3

  • S-4

    Options (Auxiliary Symbol Explanations)Shockless Type

    (Auxiliary Symbol: F)Surgeless type

    (Auxiliary Symbol: G)

    Manual Button Type (Auxiliary Symbol: N)

    Quick Return(Auxiliary Symbol: Q)

    L

    D

    Push-buttonCan be locked by pressing the button and rotating 90.

    Stroke S

    Pow

    er s

    uppl

    y

    Rec

    over

    y Ti

    me

    Lim

    iter C

    ircui

    t

    Full

    Wav

    e R

    ectif

    ier C

    ircui

    t

    Surg

    e ab

    sorb

    er

    Sole

    noid

    SW

    HandlingzThis type is used in the case of power sup-

    ply type E* (with built-in rectifier) to shortenthe spring return time. This also applies toD*.

    xThe quick return mechanism is built in.

    Model L S D

    SS-G01AC solenoid 133.5(5.26) 7.5

    (0.30)30

    (1.18)DC solenoid 140.5(5.53)

    SS-G03AC solenoid 155.5(6.12) 9.5

    (0.37)35

    (1.38)DC solenoid 173.5(6.83)

    FeaturesSmooth start and stop perfor-

    manceQuiet operationLong life and reliable opera-

    tions

    EffectsEliminates shocks in the pip-

    ing system.Prevents the piping connec-

    tions from leaking oil.Extends the l i fe of the

    hydraulic components.Maintenance-free operation

    of the hydraulic system.

    T

    A B

    P

    W=150kg63x 35x300

    SS-G03-C5-FR-D2-J21

    D

Recommended

View more >