13
Lined Up by Compact Design Wiring Variations Wiring Specifications (Class B coil) Grommet DIN terminal Conduit Conduit terminal VCA20 Class 2 VCA30 Class 3 VCA40 Class 4 Large flow rate: TV factor 0.33 to 2.11 Enclosure: Dusttight Low jetproof (Equivalent to IP65) Electrical entry directions Compact: Single valve volume reduced by –13% (Class 2) Weight reduced by –25% (Class 2) Manifold length reduced by –22% (Class 2 : 5 stations) (SMC comparison) A variety of wiring options Grommet, DIN terminal, Conduit, Conduit terminal New compact coil reduces the overall size and weight of the valve. Volume: –13% Weight: –25% SMC comparison (Class 2) Spacial bracket can be mounted. Flame resistance equivalent to UL94 standard V-0 Built-in surge voltage suppressor • Noise prevention • Burn-out prevention Special construction reduces operating resistance. Built-in rectifying circuit (AC) Improved durability (Nearly twice the life of the previous series) Resistance of moving parts has been reduced. Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated 2 Port Solenoid Valve For Air Series VCA Compact and lightweight Flame resistant molded coil material Threaded for bottom mounting When shipped from our factory, the electrical entry is set in the IN port side. 17-2-7 VC VDW VQ VX2 VX VX3 VXA VN LVC LVA LVH LVD LVQ LQ LVN TI/ TIL PA PAX PB

Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Lined Up by Compact Design

Wiring Variations

Wiring Specifications (Class B coil)

Grommet DIN terminal

Conduit Conduit terminalVCA20Class 2

VCA30Class 3

VCA40Class 4

Large flow rate: TV factor 0.33 to 2.11

Enclosure: DusttightLow jetproof (Equivalent to IP65)

Electrical entry directions

Compact: Single valve volume reduced by –13% (Class 2)Weight reduced by –25% (Class 2)Manifold length reduced by –22% (Class 2 : 5 stations) (SMC comparison)

A variety of wiring optionsGrommet, DIN terminal,Conduit, Conduit terminal

New compact coil reduces the overall sizeand weight of the valve.

Volume: –13%

Weight: –25%SMC comparison (Class 2)

Spacial bracket can be mounted.

Flame resistance equivalent toUL94 standard V-0

Built-in surge voltage suppressor

• Noise prevention • Burn-out prevention

Special construction reduces

operating resistance.

Built-in rectifying circuit (AC)

Improved durability (Nearly twice the life of the previous series)Resistance of moving parts has been reduced.Service life and wear resistance are improved.

Electrical entry is availablefrom four directions

SM

C

1

Direct Operated 2 Port Solenoid ValveFor Air

Series VCA

Compact and lightweight

Flame resistant molded coil material

Threaded for bottom mounting

∗ When shipped from our factory, the electrical entry is set in the IN port side.

17-2-7

VC�

VDW

VQ

VX2

VX�

VX3

VXA

VN�

LVC

LVA

LVH

LVD

LVQ

LQ

LVNTI/TIL

PA

PAX

PB

Page 2: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Operation by Manual Override

WarningDisassembly and Reassembly

CautionOperation

Closed state (Vertical slot) Open state (Horizontal slot)

Opening the valve: Turn 90° clockwise by a flat head screwdriver to open the valve. Besides, the valve remains in the open state even when a screwdriver is detached.

Closing the valve: Turn 90° counterclockwise from the open state to the original state to close the valve.

Perform an eletrical operation at the position where the valve is closed.

• Cut off the electrical power and pressure supply, and release the residual pressure before dissembling.

• Disassembly procedure1. Remove the mounting

screws on the top.2. Remove the solenoid coil,

spring and armature assembly.

3. If foreign matter is adhering to the parts, perform an appropriate procedure, such as blowing with air or cleaning with neutral detergent.

• Assembly procedureRe-assemble by following the disassembly procedure in the reverse order.When changing the electrical entry direction, mount it in the direction that solenoid coils will be mounted.

Note 1) For series VCA30, the end of the spring with the smaller O.D. is fitted over the armature ass'y. Be sure to make this distinction when assembling.

Note 2) Tighten the four mounting screws in a diagonally crossing order, and use the proper tightening torque below.

Proper Tightening TorqueVCA20VCA30VCA40

0.4 to 0.5

0.6 to 0.8

0.6 to 0.8

(N·m)

Mounting screw

Solenoid coil

Directionalfor springVCA30 only

Armature assembly

O-ring

Body

PrecautionsBe sure to read before handling. Refer to page 17-6-3 Safety Instructions and Solenoid Valve Precautions.

Series VCA

17-2-8

Page 3: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Glossary

1. Maximum operating pressure differentialThis indicates the maximum pressure differential (inlet and outlet pressure differential) which can be allowed for operation with the valve closed or open.

2. Maximum operating pressureThis indicates the limit of pressure that can be applied inside the pipelines. (Line pressure)

3. Withstand pressureThe pressure which must be withstood without a drop in performance after returning to the operating pressure range (The value under the prescribed conditions).

Pressure

1. MaterialHNBR: Nitrile hydride rubber

2. JIS symbolIn the JIS symbol ( ) IN and OUT are in a blocked condition ( ), but actually in the case of reverse pressure (OUT > IN), there is a limit to the blocking capability.( ) is used to indicate that blocking of reverse pressure is not possible.

Others

1. Surge voltageA high voltage which is momentarily in the shut-off unit by shutting off the power.

Electricity

PrecautionsBe sure to read before handling. Refer to page 17-6-3 for Safety Instructions and Solenoid Valve Precautions.

17-2-9

Series VCADirect Operated 2 Port Solenoid ValveFor Air

VC�

VDW

VQ

VX2

VX�

VX3

VXA

VN�

LVC

LVA

LVH

LVD

LVQ

LQ

LVNTI/TIL

PA

PAX

PB

Page 4: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Direct Operated 2 Port Solenoid Valve For Air

Series VCAHow to Order Valves (Single Unit)

For air

234

Class 2Class 3Class 4

Series

NilA

General airDry air

Fluid

VC A 2 1 1 G 3 02

NilF

NoneFoot type bracket

Option

NilB

NoneSlotted locking type (Tool required)

Manual override

NilFNT

RcG

NPTNPTF

Bracket assembly part no.VCA20-12-1AVCA30-12-1AVCA40-12-1A

Valve modelVCA21VCA31VCA41

Thread type (for single unit only)

Symbol02030406

Port size1/4 (8A) 3/8(10A)1/2(15A)3/4(20A)

Class 2�

———

Class 3�

——

Class 4—�

Port size

Symbol345710

Orifice size (mmø)3457

10

Class 2�

—�

——

Class 3—�

—�

Class 4——�

Orifice size123456

36

100 VAC200 VAC110 VAC220 VAC24 VDC12 VDC

230 VAC

Voltage

1

N.C.

Valve type

Electrical entry

∗ Refer to the below table for orifice and port size combinations.

G – Grommet C – Conduit

Connector

∗ All types are equipped with surge voltage suppressor.

3

4

5

7

10

1/4 (8A)

1/4 (8A)

3/8 (10A)

3/8 (10A)

1/2 (15A)

3/4 (20A)

ClassOrifice size (mmø)

2

3

4

Table (1) Orifice and Port Size Combinations

Port size

Table (2) Bracket Assembly Part No.

OUT(2)

IN(1)

∗ Mounting screws (2 pcs.)

∗ Please consult with SMC regarding other voltages.

∗ When a bracket is separately required, refer to Table 2 given below.

T – Conduit terminalTL – Conduit terminal with

indicator light

D – DIN terminalDL – DIN terminal with

indecator lightDO – DIN terminal

(without connector)

For details about certified products conforming to international standards, visit us at www.smcworld.com.

17-2-10

Page 5: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Standard Specifications

Valve construction

Fluid

Withstand pressure (MPa)

Body material

Seal material

Ambient temperature (°C)

Fluid temperature (°C)

Enclosure

Environment

Valve leakage cm3/min (ANR)

Mounting orientation

Vibration/Impact resistance (m/s2)

Rated voltage

Allowable voltage fluctuation

Coil insulation type

Power consumption

Apparent power

Coi

l sp

ecifi

catio

ns

Direct operated poppet

Air, Inert gas, Low vacuum (133 Pa·abs)

2.0

Al

HNBR

–20 to 60

–10 to 60 (No freezing)

Dusttight, low jetproof (equivalent to IP65)

Location without corrosive or explosive gases

0.2 or less

Unrestricted

30/150 or less

24 VDC, 12 VDC, 100 VAC, 110 VAC, 200 VAC, 220 VAC, 230 VAC (50/60 Hz)

±10% of rated voltage

Class B

VCA 2: 6.5 W, VCA 3: 8 W, VCA 4: 11.5 W

VCA 2: 7.5 VA, VCA 3: 10 VA, VCA 4: 13 VA

Characteristic Specifications

Made to Order Specifications

VCA(for air)2 port

solenoidvalve

ClassModel

3

5

4

7

5

7

10

Orificesize

(mmø)

1.0

0.15

1.0

0.15

1.0

0.3

0.15

1.1

2.9

1.9

5.0

3.0

5.4

7.7

0.45

0.21

0.24

0.16

0.35

0.27

0.23

0.29

0.68

0.45

1.2

0.78

1.4

1.9

Max. operating pressure

differential(MPa)

Flow characteristics

C [dm3/(s<·bar)] b CvPort size

1/4 (8A)

1/4 ( 8A)3/8 (10A)

3/8 (10A)1/2 (15A)3/4 (20A)

2

3

4

(1)

Note 1) Weight values are for the grommet type.

Note) Fluid: Air. Refer to VCW for model numbers and characteristics.

Max.operatingpressure

(MPa)

1.0

1.0

1.0

Weight(kg)

0.21

0.30

0.50

DC

AC(1)

(2)

50 Hz

60 Hz

Normally open (N.O.) specifications

VCA 1A–���–�– �–�–X15234

VCW 2–���–�– �–��–X43234

Oil-free specifications

Note 1) Since AC coil uses a rectifying circuit, there is no difference in apparent power between inrush and holding.

Note 2) Vibration resistance ···· Conditions when tested with one sweep of 10 to 300 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states. No malfunction occured when tested. (Value at initial state)

Impact resistance ········ Conditions when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states. No malfunction occured when tested. (Value at the initial state).

Val

ve

spec

ifica

tions

Please contact SMC for detailed specifications, delivery, and price.

17-2-11

Series VCADirect Operated 2 Port Solenoid ValveFor Air

VC�

VDW

VQ

VX2

VX�

VX3

VXA

VN�

LVC

LVA

LVH

LVD

LVQ

LQ

LVNTI/TIL

PA

PAX

PB

Page 6: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Construction

Bracket Assembly Dimensions

No.

Solenoid coil

Armature assembly

Return spring

O-ring

Body

Description

Component Parts

Bracket Mounting Dimensions/Bracket Material: Stainless Steel

Material

Stainless steel, HNBR, PPS

Stainless steel

HNBR

Aluminum

Assembly part no.

VCA20-12-1A

VCA30-12-1A

VCA40-12-1A

A

41

48

50

B

52

56

62

C

30

36

38

D

40

44

50

H

4.5

5.5

5.5

J

6

7

7

A

C

J

B D

2-øHValve mounting hole

4-ø6

Valve mounting screws

1.5

IN

∗ 2 mounting screws (for mounting brackets) are included in bracket part no.

(mm)

q

e

r

t

w

q

w

e

r

t

Series VCA

17-2-12

Page 7: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Dimensions

Model A

18243035

PPort size

1/41/4, 3/83/8, 1/2

3/4

Grommet: G Conduit: C

DIN terminal: D Conduit terminal: T

Q27303232

R 40485658.5

Q46505252

R 36445355.5

Q63666969

R 35425153.5

S51545757

Q98

101104104

R36 44 53 55.5

S68717474

U 81 91.5101 103.5

B

41506068

C

64768691

D

28344040

E

11.5141517.5

F

15172020

K

20.5253034

L

12.8192323

M

M4M5M5M5

Electrical entry

Grommet: G Conduit: C DIN terminal: D Conduit terminal: T

(mm)

D

E

CRL

A

Q F

B

K

2-PPort size

2-PPort size

D

E

A

G1/2

G1/2

2-MThread depth 6

Manual override

L

K 2-MThread depth 6

L

K 2-MThread depth 6

L

K 2-MThread depth 6

CR

Q F

B

≅300 ≅280

FF (Q)

QS

(S)

E

R≅44

C RC

A

D

B B2-P

Port size

E

AD 2-P

Port size

G1/2

Port size G1/2

U

Compatible heavy-duty cordCable O.D. ø6 to ø12

IN

Manual override

VCA21VCA31

VCA41

2

25

34

17-2-13

Series VCADirect Operated 2 Port Solenoid ValveFor Air

VC�

VDW

VQ

VX2

VX�

VX3

VXA

VN�

LVC

LVA

LVH

LVD

LVQ

LQ

LVNTI/TIL

PA

PAX

PB

Page 8: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

How to Order Valves (VCA20)

How to Order Manifold (VCA20)

VV2C A 2 02 How to Order Manifold AssemblyEnter the mounting valve and option part numbersunder the manifold base part number.

<Ordering Example>VV2CA2-0502 ···········∗ VCA23-5G-3 ···········

1 set Manifold part no.5 sets Valve part no. (Stations 1 to 5)

For air

2 Class 2

Series

NilFNT

RcG

NPTNPTF

Thread type

02 1/4 (8A)

OUT port size

NilA

SideFront

IN port direction

Electrical entryNilT

Grommet, Conduit, DINConduit terminal

02

10

2 stations

10 stations

Stations

VC A 2 3 1 G

For air

2 Class 2

Series

3 N.C. for manifold

Valve type

123456

36

100 VAC200 VAC110 VAC220 VAC24 VDC12 VDC

230 VAC

Voltage

NilA

General airDry air

Symbol35

Orifice size (mmø) 35

Orifice size

GCT

TLD

DLDO

GrommetConduitConduit terminalConduit terminal with indicator lightDIN terminalDIN terminal with indicator lightDIN terminal (without connector)

Electrical entry

NilB

NoneSlotted locking type (tool required)

Manual override

D side

U side

1

2

3

4

5

02

Fluid

3

“∗” is the symbol for assembly. Add an “∗” in front of the part numbers for solenoid valves, etc., to be mounted.

Enter together in order, counting from station 1 on the D side.

∗ Please consult with SMC regarding other voltages.

∗ All types equipped with surge voltage suppressor.

... ...

Series VCA

17-2-14

Page 9: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

How to Order Valves (VCA30/40)

How to Order Manifold Assembly

<Ordering Example>VV2CA3-05 ···············∗ VCA35-5G-4-03 ······

D side

U side

1

2

3

4

5

03

NilFNT

RcG

NPTNPTF

VC A 5 1 G

For air

34

Class 3Class 4

Series

5 N.C. for manifold

123456

36

100 VAC200 VAC110 VAC220 VAC24 VDC12 VDC

230 VAC

NilA

General airDry air

Thread type

GCT

TLD

DLDO

GrommetConduit

Conduit terminalConduit terminal with indicator light

DIN terminalDIN terminal with indicator light

DIN terminal (without connector)

Electrical entry

∗ All types equipped with surge voltage suppressor.

NilB

NoneSlotted locking type (Tool required)

Manual override

Fluid

3

Symbol030406

Size3/8 (10A) 1/2 (15A)

3/4 (20A)

Class 3�

Class 4—�

Port size (OUT)

Symbol45710

Orifice size (mmø) 457

10

Class 3�

—�

Class 4—�

Orifice size

4

How to Order Manifold (VCA30/40)

VV2C A 02For air

34

Class 3Class 4

Series

NilFNT

RcG

NPTNPTF

Thread type

NilA

SideFront

IN port direction

02

10

2 stations

10 stations

Stations

3

Valve type

Voltage

Enter the mounting valve and option part numbersunder the manifold base part number.

1 set Manifold part no.5 sets Valve part no. (Stations 1 to 5)

“∗” is the symbol for assembly. Add an “∗” in front of the part numbers for solenoid valves, etc., to be mounted.

Enter together in order, countingfrom station 1 on the D side.

... ...

∗ Please consult with SMC regarding other voltages.

17-2-15

Series VCADirect Operated 2 Port Solenoid ValveFor Air

VC�

VDW

VQ

VX2

VX�

VX3

VXA

VN�

LVC

LVA

LVH

LVD

LVQ

LQ

LVNTI/TIL

PA

PAX

PB

Page 10: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Dimensions: VCA20 Manifold

2 67.577.5

107.5117.5

3 96

106136146

4124.5134.5164.5174.5

5153163193203

6181.5191.5221.5231.5

7210220250260

8238.5248.5278.5288.5

10295.5305.5335.5345.5

9267277307317

IN port direction

Side ported

Front ported

L1

L2

L1

L2

Dimensions (mm)

D side U sideStations 1 2 3 4 5 n

Side ported: L1 = n x 28.5 + 10.5 L2 = n x 28.5 + 20.5Front ported: L1 = n x 28.5 + 50.5 L2 = n x 28.5 + 60.5

L n

2 73.583.5

113.5123.5

3108118148158

4142.5152.5182.5192.5

5177187217227

6211.5221.5251.5261.5

7246256286296

8280.5290.5320.5330.5

10349.5359.5389.5399.5

9315325355365

IN port direction

Side ported

Front ported

L1

L2

L1

L2

Dimensions (mm)Side ported: L1 = n x 34.5 + 4.5 L2 = n x 34.5 + 14.5Front ported: L1 = n x 34.5 + 44.5 L2 = n x 34.5 + 54.5

L n

(When the electrical entry of a valve to be mounted is conduit terminal.)

5

25

2

25 19.5

L2 (Front ported)L1 (Front ported)

72

l = 3

00l =

280

(68)

5133

14

(98)

6248

26.4

27

P = 28.5 24.5

5542

38.5

37

12

512.5

L2 (Side ported)L1 (Side ported)

14

2512

.5

Mounting valve: for conduit terminal (P = 34.5)

Manual overrideManual override

(Front ported)IN port2-3/8

Mounting holes2-ø 5.6

OUT portn-1/4

IN port (Side ported)2-Rc3/8

Series VCA

17-2-16

Page 11: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Dimensions: VCA30/40 Manifold

2103114139150117128161172

3138149174185158169202213

4173184209220199210243254

5208219244255240251284295

6243254279290281292325336

7278289314325322333366377

8313324349360363374407418

10383394419430445456489500

9348359384395404415448459

IN port direction

Side ported

Front ported

Side ported

Front ported

Model

VV2CA3

VV2CA4

Dimensions

L1

L2

L1

L2

L1

L2

L1

L2

L Dimension (mm)

U sideD sideStations 1 2 3 4 5 n

n (stations)

Model

VV2CA3

VV2CA4

A

5562

Q

3032

R

3641

S

5052

T

3238

U

5457

V

6669

W

3036

Y

101104

X

7174

Z

65.571

Electrical entry

Grommet: G Conduit: C DIN terminal: D Conduit terminal: T

(mm)Dimensions

B

2631

C

1719

E

19.521

F

33 39.5

G

2631

H

3543

J2

39.543.5

K

3541

J3

57.565.5

J1

23.527

L

26.529

M

41.548

N

5055

V( Y

)

�=

280

L1 (Front ported)L2 (Front ported)

HG C BA

E

J3P = K (Pitch)

L

1 1

1

22 2 2

Q�=

300

S

W T RN

ZM

U

5.5

5.5L2 (Side ported)

L1 (Side ported)

2-ø6.4Mounting holes

2-1/2(VCA30), 3/4(VCA40)IN port (Side ported)

n-3/8, 1/2 (VCA30)n-1/2, 3/4 (VCA40)

OUT port

FormulasVV2CA3Side ported: L1 = n x 35 + 33, L2 = n x 35 + 44Front ported: L1 = n x 35 + 69, L2 = n x 35 + 80VV2CA4Side ported: L1 = n x 41 + 35, L2 = n x 41 + 46Front ported: L1 = n x 41 + 79, L2 = n x 41 + 90

16

For manual override

Manual override

J1

Manual override

(X)

J2

25

F

2-1/2 (VCA30), 3/4 (VCA40)

IN port (Front ported)

17-2-17

Series VCADirect Operated 2 Port Solenoid ValveFor Air

VC�

VDW

VQ

VX2

VX�

VX3

VXA

VN�

LVC

LVA

LVH

LVD

LVQ

LQ

LVNTI/TIL

PA

PAX

PB

Page 12: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Manifold Exploded View

Series VCA20

Series VCA30/40

No.

q

w

e

r

M3 x 57VCA23�-���-�VVCA20-3-1VV2CA2-���-�

Part no. Material

Steel

HNBR

Aluminum

Description

Cross-recessed head machine screw

Valve for manifold

Gasket

Manifold base

No.

q

w

e

r

t

y

Part no.

AXT632-69-1AXT632-69-2VVCA30-3A-04-2VVCA30-3A-04-1OR-2200-200-HVCA35�-��-�-��

VVCA30-6-nVVCA30-4A-04-2VVCA30-4A-04-1

Material

Steel

Aluminum

HNBR

Steel

Aluminum

Material

Steel

Aluminum

HNBR

Steel

Aluminum

Description

Mounting screw (side port)

Mounting screw (front port)

End plate assembly (D side, side port)

End plate assembly (D side, front port)

O-ring (for VCA30)

Manifold valve

Tie-rod

End plate assembly (U side, side port)

End plate assembly (U side, front port)

Series VCA30Part no.

AXT632-69-1AXT632-69-2VVCA40-3A-06-2VVCA40-3A-06-1OR-3200-200-HVCA45�-��-�-��

VVCA40-6-nVVCA40-4A-06-2VVCA40-4A-06-1

Mounting screw (side port)

Mounting screw (front port)

End plate assembly (D side, side port)

End plate assembly (D side, front port)

O-ring (for VCA40)

Manifold valve

Tie-rod

End plate assembly (U side, side port)

End plate assembly (U side, front port)

Series VCA40

(1)

Note 1) Gasket e is included with manifold valve w.

Note 2) O-ring e is included with manifold valve r. Note 2) O-ring e is included with manifold valve r.

(2) (2)

Mount it as shown above. Mounting orientation exists when mounting valves onto manifold base.

Gasket

Manifold body

Manifold base A port side

Manifold body

q

w

e

r

qw

e

r

t

y

DescriptionNo.

q

w

e

r

t

y

Series VCA

17-2-18

Page 13: Direct Operated 2 Port Solenoid Valve For Air Series VCA · Service life and wear resistance are improved. Electrical entry is available from four directions SMC 1 Direct Operated

Manifold Option Parts

Blanking plate assembly (VCA20)

34

Series VCA30Series VCA40

34

Series VCA30Series VCA40

VVCA20 4A

Blanking block assembly (VCA30, 40)

Tie-rod for additional stations (Set of 2 pcs for 1 station) (VCA30, 40)

VVCA 3 0 6 1A

VVCA 3 0 2A 00

This is used when a blanking plate is mounted on a manifold as preparation for a planned valve installation. (With gasket, 2 mounting screws)

This is used when a blanking plate is mounted on a manifold as preparation for a planned valve installation. (With O-ring)

Mounted on the tie-rod when adding one station.

17-2-19

Series VCADirect Operated 2 Port Solenoid ValveFor Air

VC�

VDW

VQ

VX2

VX�

VX3

VXA

VN�

LVC

LVA

LVH

LVD

LVQ

LQ

LVNTI/TIL

PA

PAX

PB