testo 6383 / testo 6381 / testo 6351

Committing to the future

Differential Pressure, Temperature and Humidity Monitoring Testo transmitters provide the highest accuracy, with long-term stability and maximum uptime

netzerotools.com

netzerotools.com

netzerotools.com

Page 2: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Testo 0572 0250 Saveris Kit 1 IAQ Data Logger Testo 0572 0182 Saveris Software 21cfr11 IAQ Testo 0628 0024 Saveris Water Activity AW Probe Assembly Testo 0572 0261 Saveris Base IAQ Data Logger Testo 0572 0260 Saveris Base IAQ Data Logger Testo 0628 0022 Saveris Flexible Relative Humidity Probe Testo 0555 6743 Saveris Dew Point Transmitter Testo 0555 6744 Saveris Dew Point Transmitter Testo 0628 2432 Saveris PT100 Immersion Probe Testo 0572 0181 Saveris Software Prof IAQ Testo 0628 0021 Saveris High Temperature RH Probe Testo 0555 6444 Saveris Compressed Air Flow Transmitter Testo 0555 6443 Saveris Compressed Air Flow Transmitter Testo 0555 6442 Saveris Compressed Air Flow Transmitter Testo 0555 6441 Saveris Compressed Air Flow Transmitter Testo 0555 6741 Saveris Dew Point Transmitter Testo 0555 6742 Saveris Dew Point Transmitter Testo 0555 3314 Saveris Dual Pressure Calibrator Testo 0555 3303 Saveris Dew Point Measuring Chamber Testo 0555 6383 Saveris Differential Pressure Transmitter Testo 0555 6381 Saveris Differential Pressure Transmitter Testo 0555 6351 Saveris Differential Pressure Transmitter Testo 0555 6321 Saveris Differential Pressure Transmitter Testo 6337 9741 Saveris Humidity Temp Transmitter Testo 0555 6681 Saveris Industrial Relative Humidity Transmitter Testo 0572 6262 Saveris H2D Wireless Humidity Temp Probe Testo 0572 6194 Saveris H4E Ethernet Humidity Probe Testo 0555 6651 Saveris Industrial Relative Humidity Transmitter Testo 0572 6264 Saveris H4D Wireless Humidity Td Recorder Testo 0572 6191 Saveris H1E Ethernet Humidity Probe Testo 0572 9194 Saveris T4E Ethernet Thermocouple Probe Testo 0572 6192 Saveris H2E Ethernet Humidity Probe Testo 0628 0035 Robust Hot Bulb Probe Testo 0554 8765 Modular Probe Shaft Replacement Testo 0602 0743 Globe Probe Thermocouple Type K

netzerotools.com

netzerotools.com

Page 3: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Testo 0602 2394 Flat Head Surface Probe Thermocouple Testo 0628 0016 PT100 Flexible Precision Immersion Probe Testo 0572 6260 Saveris H3D Wireless Humidity Probe NTC Testo 0572 3190 Saveris U1E Analog Ethernet Converter Testo 0572 7191 Saveris PTE Ethernet Probe PT100Testo 0628 0017 PT100 Precision Air Probe Eeprom Testo 0555 6686 Saveris Profibus DP Module Testo 0572 6250 Saveris H3 Wireless Humidity Probe NTC Testo 0628 0015 PT100 Immersion Penetration Probe Testo 0554 3312 Saveris Precision Measurement Chamber Testo 0572 6174 Saveris Humidity Temperature Probe Testo 0572 7261 Saveris PTD Wireless Probe Testo 0572 9262 Saveris T3D Wireless Thermocouple Probe Testo 0554 0743 Saveris IAQ Tripod Testo 0555 6721 Saveris Pressure Dewpoint Guard Switch Testo 0572 0158 Saveris Wireless To Ethernet Converter Testo 0572 0258 Saveris Wireless To Ethernet Converter Testo 0572 0180 Saveris Software SBE IAQ Testo 0572 3250 Saveris U1 Analog Wireless Converter Testo 0554 8764 Probe Shaft With Probe Stop Testo 0572 0183 Saveris Adjustment Software Testo 0572 7251 Saveris PT Wireless Probe Testo 0572 9252 Saveris T3 Wireless Thermocouple Probe Testo 0555 6722 Saveris Alarm Box Testo 0572 1191 Saveris T1E Ethernet NTC Probe Testo 0554 0660 Saveris RH Probe Salt Solution Set Testo 0554 6656 Saveris Ethernet Module For 6381 6351Testo 0572 1261 Saveris T2D Wireless NTC Temperature Probe Testo 0572 1260 Saveris T1D Wireless NTC Temperature Probe Testo 0628 2232 Saveris PT100 Immersion Penetration Probe Testo 0602 4792 Saveris Magnetic Surface Temp Probe Testo 0572 1251 Saveris T2 Wireless NTC Temperature Probe

netzerotools.com

netzerotools.com

Page 4: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Testo 0554 5762 Modular Multi Hole Flue Gas Probe Testo 0602 4892 Saveris Magnetic Surface Temp Probe Testo 0628 9992 Saveris Cooking Surface Temp Probe Type K Testo 0572 6172 Saveris Humidity Temp Probe 12mm Testo 0554 3313 Saveris Flow Through Meter Testo 0602 4592 Saveris Pipe Clamp Temperature Probe Testo 0602 0493 Saveris Low Mass Immersion Tip Testo 0602 0993 Saveris Fast Action Typek Surface Probe Testo 0613 3211 Saveris Frozen Food NTC Temp Probe Testo 0572 0159 Saveris Wireless Router 2.4ghz V1.0Testo 0572 0259 Saveris Wireless Router 2.4ghz V2.0Testo 0572 1250 Saveris T1 Wireless NTC Temperature Probe Testo 0628 1932 Saveris PT100 Surface Temp Probe Testo 0628 1232 Saveris PT100 Immersion Penetration Probe Testo 0613 5605 Saveris Pipe Clamp Temperature Probe NTC Testo 0554 3304 Saveris Measuring Chamber Cooling Coil Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple Testo 0628 0026 Saveris Penetration Needle Probe Testo 0554 3302 Saveris Connection Plug 2 Alarm Points Testo 0613 3311 Saveris Penetration Food Probe NTC Testo 0613 2211 Saveris Penetration Food Probe NTC Testo 0602 2292 Saveris Penetration Food Probe Type K Testo 0613 1052 Saveris Frozen Food Probe Tip Testo 0602 2492 Saveris Food Penetration Probe Type K Testo 0628 0027 Saveris Penetration Needle Probe Testo 0628 1292 Saveris Immersion Penetration Probe Testo 0613 2411 Saveris Food Penetration Probe NTC Testo 0613 1002 Saveris Penetration Wireless NTC Probe Testo 0554 1796 Saveris Pressure Tight Screw Connector Testo 0554 1749 Saveris Base Power Supply Testo 0602 0693 Saveris Surface Probe Type K Thermocouple Testo 0602 0393 Saveris Surface Probe Thermocouple Type K

netzerotools.com

netzerotools.com

Page 5: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Testo 0554 6687 Saveris Profibus T Piece Plug Connector Testo 0555 9999 4 Saveris Type K Thermocouple Cable Testo 0554 0662 Saveris Humidity Control Adjustment Salt Testo 0602 2693 Saveris Immersion Penetration Probe Type K Testo 0554 1748 Saveris Base Power Supply Testo 0554 1143 Desktop AC Power Supply Charger Testo 0554 1096 Saveris Power Supply Charger 240 VAC Testo 0554 1105 Saveris Power Supply 5 Volts Testo 0610 1725 Saveris NTC Temperature Probe Testo 0628 0006 Saveris Immersion NTC Temperature Probe Testo 0613 1212 Saveris Immersion NTC Temperature Probe Testo 0628 0030 Saveris Superfast Penetration Needle Probe Testo 0602 0593 Saveris Immersion Type K Thermocouple

netzerotools.com

netzerotools.com

Page 6: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Differential pressure measurement

2

air delivery via HEPA/ULPA filter

Typical exhaust air: (50 - 500air exchanges / h)

Laminar flow

OutsideCritical zoneNormal zone

Whether in pharma-biotech production, semiconductor fabs, or critical product filling systems...

... differential pressures must be maintainedbetween different rooms or zones in order to preventcontaminated air from entering the critical zone. For example,

For this reason, continuous measurement and controlof these important differential pressures is required.Secure proof of control, drift maintenance, routine service andcalibrations-adjustments must be maintanined as part of a .

Operation of the automatic zero-point adjustment in Testo differential pressure transmitters

Differential pressure maintenance in critical environments

Cleanroom

In the automatic zero-point adjustment, a magnetic valvecauses both sides of the pressure sensor (S) to be exposedto the same pressure at routine intervals. This ensureshighest accuracy in any critical process or controlled area.

Normal measurement Zero-point adjustment

secure data base. This is required by a wide range of federal, state, local, industy, and company-specific regulations.

and control in critical environments

Testo's unique Automatic

... ensures your differential pressure set points are always maintained by re-zeroing the differential pressure sensor at routine time intervals. This ensures drift-free measurements,

In hospitals and research laboratories, the pressuredifference (negative pressure) prevents the spread of

germs, contaminants and dust

Positive pressure in the filling room maintains thehygiene conditions during filling operations in the food

and pharamceuticals industry

Controlled pressure differences between cleanrooms and adjacent rooms helps ensure a controlled

Zero-Point Adjustment...

temperature-independent accuracy and long term stability.

6351 all come standard with an automatic microprocessor-controlled zero-point adjustment system.

The zero-point stability of differential pressure transmittersplays a particularly crucial role at low pressures (eg. 0.2 or0.04 in. water measurement range). Whereas conventionaldifferential pressure transmitters require manual re-adjustmentof their zero-point, Testo transmitter Series 6383, 6381 and

Magnetic valve Magnetic valve

Magnetic valveopen

Magnetic valveclosed

environment

zone

the "" Critical Zone" would be a typical clean room or controlledenvironment. The " Normal Zone" would be a prep or changing area. The " Outside Zone" would be areas such as offices,meeting rooms, warehousing and common areas.

netzerotools.com

netzerotools.com

Page 7: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Differential pressure transmitters from Testo

3

testo 6383

Parameters

Selectable measuring ranges

Housing

Typical Applications

Typical installation site in

cleanroom

Differential pressureOptional: humidity/temperature

testo 6381

Differential pressureFlow velocityVolume flowOptional: Humidity/temperature

testo 6351

Differential pressureFlow velocityVolume flow

0.04 to 4 in. water 0.04 to 401 in. water 0.2 to 802 in. water

Flat panel stainless steel housing for flush wall installation

Metal housing, wall mount Plastic housing, wall mount

Critical zone: Surface flushinstallation in cleanroom wall

Normal zone or outside zone

Normal zone or outside zone

Differential pressure monitoringbetween cleanrooms

Monitoring positive and negativepressure in cleanrooms,operating theatres and isolationrooms

Additional monitoring of humidityand temperature in cleanrooms(opt.) via interchangeable probes

Differential pressure monitoringbetween cleanrooms and (opt.)simultaneous measurement oftemperature and humidity via

Differential pressure monitoring infilling processes and spray-painting systems

Monitoring drying processes

Differential pressure monitoringbetween cleanrooms

Differential pressure monitoring infilling processes in processindustries

Critical air conditioningtechnology (cVAC systems)

testo P2A Software: optimizing processes and saving commissioning and maintenance time

The Testo transmitters are delivered ready to use. For easy multi-unitprogramming and commissioning, the following functions are availablevia Testo's P2A (Programming, Adjustment and Analysis) software:

– Programming measuring unit and scale

– Sensor adjustment and adjustment of the analog outputs(humidity: 1-point, 2-point; pressure: n-point)

– Programming and adjustment history of all operations in theP2A software for each transmitter serial number is logged in the PC

Adjustment of the entire signal chain is possible directly atthe measurement site thanks to each transmitter's externalinterface. This saves time and money in commissioning

Additionally, complete parameter files for each transmitter can be stored inthe PC. Programming of spare transmitters or transfer to new measuring points is easily performed using testo P2A software.

Ethernet networking – Integration of transmitters into exisiting Ethernet network– Integration of transmitters into testo Saveris multipoint Ethernet and/or wireless mointoring systemTM

Using testo P2A software, unit and scale are easily programmed and recorded

and maintenance.

interchangeable probes

netzerotools.com

netzerotools.com

Page 8: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

testo 6383 – Major features and benefits· Measurement of differential pressure (optional: humidity and

temperature) in one flat panel design unit

· Automatic zero-point adjustment ensures optimal temperature-independent accuracy, long-term stability, and maximum uptime

· Low measurement range -0.04 to +0.04 in. water ensures highestprecision at lowest pressures

· Flat housing allows flush surface integration in the cleanroom wall

4

testo 6383 for differential pressuremeasurement can accept opt. internal

testo 6383 model can accept opt. cable

· Combination of differential pressure, humidity, and temperaturemeasurement in one instrument saves investment costs(interchangeable digital humidity probes: see page 10)

· Display with multi-language operating menu and visual alarmdisplay

· Ethernet, relay and analog outputs allow optimum integration intoa range of automation and control systems

· Self-monitoring ("Early Warning) system in the transmitters ensuresmaximum uptime

· testo P2A software (Prograqmming, Adjustment and Analysis)saves time and costs in commissioning and maintenance

· Scalable measuring range by ±50 percent of the measuring rangefinal value, plus free scalability within the measuring range, allowoptimum adaptation even to demanding control requirements

Typical applications· Monitoring positive and negative pressure in cleanrooms, operating

theaters and isolation rooms and critical control areas

· Additional monitoring of humidity and temperature (optional)

Configuration options for testo 6383

This results in a typical ordering code:0555 6383 AXX BXX CXX DXX EXX FXX GXX HXX IXX KXX

C00C02C03C04C05

K01K02K03

D00D04D05

H00H01H02

F01F02F03F04F05F06F07F08F09F10

G01G02G03G04G05G06G07G08G09G10G11G12G13G14

G15

G16G17

B02 0 to 1 V (4-wire, 24 VAC/DC) B03 0 to 5 V (4-wire, 24 VAC/DC) B04 0 to 10 V (4-wire, 24 VAC/DC) B05 0 to 20 mA (4-wire, 24 VAC/DC) B06 4 to 20 mA (4-wire, 24 VAC/DC)

without display, without operating buttonswith di splay, with operating buttons / English with d isplay, with operating buttons / German with di splay, with operating buttons / Frenchwith di splay, with operating buttons / Spanish

no humidity/temperature probe humidity/temperature probe integrated in panelpreparation for external humidity/temperature probe testo Series 6610

Pa / min / max hPa / min / max kPa / min / max mbar / min / max bar / min / max mmH2O / min / max in. H2O / min / max inch Hg / min / maxkg/cm² / min / max PSI / min / max

% RH/Min/Max °C/Min/Max°F/Min/Max °Ctd / min / max °Ftd / min / max g/kg / min / max gr/lb /Min/Max g/m³ / min / max gr/ft³ / min / max ppmV / min / max °Cwb / min / max °Fwb / min / max kJ/kg /Min/Max (enthalpy)hPa /min/max (water vapour partial pressure) mmH2O / min / max (Water vapour partial pressure)°Ctm (mixture dewpoint for H2O2)°Ftm (mixture dewpoint for H2O2)

without relay 4 relay outputs, limit value monitoring 4 relay outputs, channel 1 limit values andcollective alarm

German/English instruction manualFrench/English instruction manual Spanish/English instruction manual

Order no. 0555 6383 Axx Bxx Cxx Dxx Exx Fxx Gxx Hxx I xx Kxx

E00E01

without Ethernet module with Ethernet module

Axx Measuring rangeBxx Analog display/supplyCxx DisplayDxx opt. Integrated humidity probeExx Ethernet Fxx Differential pressure unit (pre-set) Gxx opt. Analog output for humidity

probe connection testo Series 6610 / units (pre-set) Hxx Relay I xx Units channel 3 (pre-set, only if opt. humidity probe connection

available) Kxx Instruction Manual languages

A01A02A03A04A05A21A22A23A24A25

0 to 0.04 in. water (0 to 10 Pa) 0 to 0.2 in. water (0 to 50 Pa) 0 to 0.4 in. water (0 to 100 Pa) 0 to 2 in. water (0 to 500 Pa) 0 to 4 in. water (0 to 10 hPa) - 0.04 to 0.04 in. water (-10 to 10 Pa) - 0.2 to 0.2 in. water (-50 to 50 Pa) - 0.4 to 0.4 in. water (-100 to 100 Pa) - 2 to 2 in. water (-500 to 500 Pa) - 4 to 4 in. water (-10 to 10 hPa)

I01I02I03I04I05I06I07I08I09I10I11I12I13I14

I15

I16I17

% RH/Min/Max °C/Min/Max °F/Min/Max °Ctd / min / max °Ftd / min / max g/kg / min / max gr/lb /Min/Max g/m³ / min / max gr/ft³ / min / max ppmV / min / max °Cwb / min / max °Fwb / min / max kJ/kg /Min/Max (enthalpy)hPa /min/max (water vapor partial pressure) mmH2O / min / max (Water vapor partial pressure)°Ctm (mixture dewpoint for H2O2) °Ftm (mixture dewpoint for H2O2)

Scaling: ±50% ofmeasuring range;freely selectablewithin measuringrange

Only with selectionD04 orD05

Only with selectionD04 or D05

td dew point

wb wet bulb

tm mixture dewpoint

· Automatic overload protection protects sensors against pressure surges

temperature/humidity probeor duct temperature/humidity probes

Flat panel Differential Pressure Transmitters from Testo

Note: 4-wire installation required

netzerotools.com

netzerotools.com

Page 9: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

5

testo 6383 – Product Specifications

testo 6383

Supply

Display

Differential pressure Analog outputs

Other outputs

Housing

Miscellaneous

Display optional: 3-line LCD with multi-languageoperating menu

Technical data testo 6383

Parameters

Measuring range 0 to 10 Pa0 to 50 Pa0 to 100 Pa0 to 500 Pa0 to 10 hPa

-10 to +10 Pa-50 to +50 Pa-100 to +100 Pa-500 to +500 Pa-10 to +10 hPa

Measurement uncertainty* 0.3% of measurement range final value ±0.3 Pa Meas. cycle 1/sec

Resolution 12 bit

Scaling Differential pressure: scalable ±50% ofmeasuring range final value; freely scalable within measuring range

Overload capacity Measuring range Overload0 to 10 Pa 20000 Pa0 to to 50 Pa 20000 Pa0 to to 100 Pa 20000 Pa0 to to 500 Pa 20000 Pa0 to to 10 hPa 200 hPa-10 to to 10 Pa 20000 Pa-50 to to 50 Pa 20000 Pa-100 to to 100 Pa 20000 Pa-500 to to 500 Pa 20000 Pa-10 to to 10 hPa 200 hPa

Inputs/outputs

Output type 0/4 to 20 mA (4-wire) (24 VAC/DC)0 to 1/5 to 10 V (4-wire) (24 VAC/DC)

Relay Optional: 4 relays (free allocation tomeasurement channels or as collectivealarm in operating menu/P2A software),up to 250 VAC/3A (NO or NC)

Voltage supply 20 to 30 VAC/DC, 300mA currentconsumption, galvanically separatesignal and supply line

General technical data

Material Stainless steel housing

Dimensions without humidity/temperature: 246 x 161 x 47 mmwith humidity/temperature: 396 x 161 x 78 mm

Resolution pressure Measuring range Resolution0 to 10 Pa 0.1 Pa0 to 50 Pa 0.1 Pa0 to 100 Pa 0.1 Pa0 to 500 Pa 0.1 Pa0 to 10 hPa 0.01 hPa-10 to 10 Pa 0.1 Pa-50 to 50 Pa 0.1 Pa-100 to 100 Pa 0.1 Pa-500 to 500 Pa 0.1 Pa-10 to 10 hPa 0.01 hPa

Operating temperature (housing) -5 to 50 °C/23 to 122 °F

Storage temperature -20 to 60 °C/-4 to 140 °F

Protection class IP 65

Operating conditions

see configuration options p. 4

Sensor Piezoresistive sensor

Automatic Zero-pointadjustment

via magnetic valve, frequency adjustable:15 sec, 30 sec, 1 min, 5 min, 10 min

Humidity

Measuring range with optional internal probe:0 to 100 %RH;Model with external probe: dependent onconnected probe (see p. 10)

Measurement uncertainty dependent on connected probe (see p. 10)

Selectable units %RH, further calculated humidityparameters see configuration options p. 4

Sensor Capacitive sensor

Temperature dependency/coefficient

±0.02 %RH (at temperatures deviatingfrom 25 °C)

Measuring range dependent on connected probe (see p.10)

Measurement uncertainty 0.15 °C

Selectable units °C / °F

Sensor Pt 1000 1/3 Class B;Pt 100 1/3 Class B (with testo probe6615 for trace humidity)

Digital output Mini-DIN for P2A software

Ethernet Optional

Temperature

* Measurement inaccuracy according to GUM: ±0,5% of measurement range finalvalue ±0.3 Pa

GUM (Guide to the Expression of Uncertainty in Measurement):ISO guideline for the determination of measurement inaccuracy, in order to makemeasurement results internationally comparable. The following inaccuracies are used for the determination:– Hysteresis– Linearity– Reproducibility– Long-term stability– Adjustment site/factory calibration– Test site

Resolution humidity 0.1 %RH

Temperature resolution 0.01 °C / °F

Standard reference EU guideline 2004/108/EC

Weight Version without humidity:0.9 kg;Version with integrated humidity probe:1.350 kg; version with preparation forexternal humidity probe: 1.260 kg

Load max. 500 Ω

Quantity Standard: 1; for differential pressureoptional: 3- includes temp and RH

Measuring units

see complete listing p. 4

netzerotools.com

netzerotools.com

Page 10: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

6

testo 6381- Three transmitters in one for normal zonestesto 6381 – Major features and benefits

· Measurement of differential pressure, flowvelocity, volume flow; optional: humidity andtemperature... all in one unit

· Automatic zero-point adjustment guaranteestemperature-independent accuracy andlong-term stability for differential pressure

· Low measurement range - 0.04 to 0.04 in.water ensures high precision at low pressures

· Rugged metal housing protects against thetoughest ambient conditions

· Combination of differential pressure, humidity,and temperature measurement in oneinstrument saves investment costs( for interchangeabl e digital humidity probe seepage 10)

· Display with multi-language operatingmenu and visual alarm display

· Ethernet, relay and analog outputs allowoptimum integration into a range ofautomation systems

· testo P2A software (Programming, Adjustment,and Analysis) saves time and costsin commissioning and maintenance

· Scalable measuring range by ±50 percent ofthe measuring range final value, and freescalability within the measuring range, allowoptimum adaptation even to demanding controlrequirements

Typical applications· Differential pressure monitoring between

cleanrooms (with optional simultaneousmeasurement of ambient temperature andhumidity)

· Monitoring drying processes

· Differential pressure monitoring in fillingprocesses and spray-painting systems

Configuration options testo 6381:This results in a typical ordering code:0555 6381 AXX BXX CXX DXX EXX FXX GXX HXX IXX KXX

B02B03B04B05B06

C00C02C03C04C05

K01K02K03

D01D02D03

H00H01H02

F01F02F03F04F05F06F07F08F09F10F11F12F13F14F15F16

G00

G01G02G03G04G05G06G07G08G09G10G11G12G13G14

G15

G16G17

0 to 1 V (4-wire, 24 VAC/DC) 0 to 5 V (4-wire, 24 VAC/DC) 0 to 10 V (4-wire, 24 VAC/DC) 0 to 20 mA (4-wire, 24 VAC/DC) 4 to 20 mA (4-wire, 24 VAC/DC)

without display, without operating buttonswith display, with operating buttons / English with display, with operating buttons / German with display, with operating buttons / Frenchwith display, with operating buttons / Spanish

Cable input M16 (relay: M20)Cable entry NPT 1/2“Cable contact via M-plug connection for signal and supply

Pa / min / maxhPa / min / maxkPa / min / maxmbar / min / maxbar / min / maxmmH2O / min / max mmH2O / min / max inch HG / min / maxkg/cm² / min / maxPSI / min / maxm/s / min / maxft/min / min / maxm³/h / min / maxl/min / min / maxNm³/h / min / maxNl/min / min / max

without connection possibility forhumidity probe testo Series 6610 Probes % RH/Min/Max°C/Min/Max°F/Min/Max°Ctd / min / max°Ftd / min / maxg/kg / min / maxgr/lb /Min/Maxg/m³ / min / maxgr/ft³ / min / maxppmV / min / max°Cwb / min / max°Fwb / min / maxkJ/kg /Min/Max (enthalpy)hPa /min/max (water vapour partial pressure)mmH2O / min / max (Water vapour partial pressure)°Ctm (mixture dewpoint for H2O2)°Ftm (mixture dewpoint for H2O2)

without relay 4 relay outputs, limit value monitoring 4 relay outputs, channel 1 limit values andcollective alarm

German/English instruction manualFrench/English instruction manual Spanish/English instruction manual

Order no. 0555 6381 A01 Bxx Cxx Dxx Exx Fxx Gxx Hxx I xx Kxx

E00E01

without Ethernet module with Ethernet module

Axx Measuring rangeBxx Analog display/supplyCxx DisplayDxx Cable inputExx EthernetFxx Differential pressure/flow velocity unit (pre-set)Gxx opt. Analog output for humidity probe

A01A02A03A04A05A07A08A09A10A21A22A23A24A25A27A28A29A30

0 to 20 in. water (0 to 50 hPa)0 to 40 in. water (0 to 100 hPa)0 to 200 in. water (0 to 500 hPa)0 to 401 in. water (0 to 1000 hPa)

- 20 to 20 in. water (-50 to 50 hPa)- 40 to 40 in. water (-100 to 100 hPa)- 200 to 200 in. water (-500 to 500 hPa)- 401 to 401 in. water (-1000 to 1000 hPa)

I01I02I03I04I05I06I07I08I09I10I11I12I13I14

I15

I16I17

% RH/Min/Max°C/Min/Max°F/Min/Max°Ctd / min / max°Ftd / min / maxg/kg / min / maxgr/lb /Min/Maxg/m³ / min / maxgr/ft³ / min / maxppmV / min / max°Cwb / min / max°Fwb / min / maxkJ/kg /Min/Max (enthalpy)hPa /min/max (water vapor partial pressure)mmH2O / min / max (Water vapor partial pressure)°Ctm (mixture dewpoint for H2O2)°Ftm (mixture dewpoint for H2O2)

Scaling±50% ofmeasuringrange; freelyselectable withinmeasuring range

onlypossiblewhen GxxCode (fromG01 to G17)is selected

connection testo 6610 / units (pre-set)Hxx RelayIxx Units channel 3 (pre-set, only if opt. humidity

probe connection available)Kxx IM languages (for bilingual printed IMs)

withconnectionpossibilitytesto Series 6610 Probes

testo 6381 - Differential pressure, temperature,and humidity measurements in one rugged,easy to install unit

· Self-monitoring ("Early Warning) system in thetransmitter ensures maximum uptime

0 to 0.04 in. water (0 to 10 Pa) 0 to 0.2 in. water (0 to 50 Pa) 0 to 0.4 in. water (0 to 100 Pa) 0 to 2 in. water (0 to 500 Pa) 0 to 4 in. water (0 to 10 hPa)

- 0.04 to 0.04 in. water (-10 to 10 Pa) - 0.2 to 0.2 in. water (-50 to 50 Pa) - 0.4 to 0.4 in. water (-100 to 100 Pa) - 2 to 2 in. water (-500 to 500 Pa) - 4 to 4 in. water (-10 to 10 hPa)

Note: 4-wire installation required

netzerotools.com

netzerotools.com

Page 11: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

7

testo 6381

Supply

Display

Differential pressure Analog outputs

Other outputs

Housing

Miscellaneous

Display optional: 3-line LCD with multi-languageoperating menu

Parameters

Measuring range 0 to 10 Pa0 to 50 Pa0 to 100 Pa0 to 500 Pa0 to 10 hPa0 to 50 hPa0 to 100 hPa0 to 500 hPa0 to 1000 hPa

-10 to 10 Pa-50 to 50 Pa-100 to 100 Pa-500 to 500 Pa-10 to 10 hPa-50 to 50 hPa-100 to 100 hPa-500 to 500 hPa-1000 to 1000 hPa

Measurement uncertainty* 0.5% of measurement range final value ±0.3 Pa

Meas. cycle 1/sec

Resolution 12 bit

Scaling Differential pressure: scalable ±50% ofmeasuring range final value; freelyscalable within measuring range

Overload capacity Measuring range Overload0 to 10 Pa 20000 Pa0 to 50 Pa 20000 Pa0 to 100 Pa 20000 Pa0 to 500 Pa 20000 Pa0 to 10 hPa 200 hPa0 to 50 hPa 750 hPa0 to 100 hPa 750 hPa0 to 500 hPa 2500 hPa0 to 1000 hPa 2500 hPa-10 to 10 Pa 20000 Pa-50 to 50 Pa 20000 Pa-100 to 100 Pa 20000 Pa-500 to 500 Pa 20000 Pa-10 to 10 hPa 200 hPa-50 to 50 hPa 750 hPa-100 to 100 hPa 750 hPa-500 to 500 hPa 2500 hPa-1000 to 1000 hPa 2500 hPa

Inputs/outputs

Output type 0/4 to 20 mA (4-wire) (24 VAC/DC)0 to 1/5 to 10 V (4-wire) (24 VAC/DC)

Relay Optional: 4 relays (free allocation tomeasurement channels or as collectivealarm in operating menu/P2A software), upto 250 VAC/3A (NO or NC)

Voltage supply 20 to 30 VAC/DC, 300 mA currentconsumption, galvanically separatesignal and supply line

General technical data

Material Metal housing

Dimensions 162 x 122 x 77 mm

Resolution pressure Measuring range Resolution0 to 10 Pa 0.1 Pa0 to 50 Pa 0.1 Pa0 to 100 Pa 0.1 Pa0 to 500 Pa 0.1 Pa0 to 10 hPa 0.01 hPa0 to 50 hPa 0.01 hPa0 to 100 hPa 0.1 hPa0 to 500 hPa 0.1 hPa0 to 1000 hPa 1 hPa-10 to 10 Pa 0.1 Pa-50 to 50 Pa 0.1 Pa-100 to 100 Pa 0.1 Pa-500 to 500 Pa 0.1 Pa-10 to 10 hPa 0.01 hPa-50 to 50 hPa 0.01 hPa-100 to 100 hPa 0.1 hPa-500 to 500 hPa 0.1 hPa-1000 to 1000 hPa 1 hPa

Protection class IP 65

Selectable units Pa, further pressure and flow velocityunits see configuration options p. 6

Sensor Piezoresistive sensor

Automatic Zero-pointadjustment

via magnetic valve,frequency adjustable: 15 sec, 30 sec, 1 min, 5 min, 10 min

Humidity

Measuring range dependent on connected probe (see p. 10)

Measurement uncertainty dependent on connected probe (see p. 10)

Selectable units %RH, further calculated humidityparameters see configuration options p. 6

Sensor Capacitive sensor

Temperaturedependency/coefficient

±0.02 %RH (at temperatures deviatingfrom 25 °C)

Measuring range dependent on connected probe (see p.10)

Measurement uncertainty 0.15 °C

Selectable units °C / °F

Sensor Pt 1000 1/3 Class B;Pt 100 1/3 Class B (testo 6615)

Digital output Mini-DIN for P2A software

Ethernet Optional with Ethernet module

Temperature

Weight 1,960 kg; optional: Ethernet intermediarylayer 0.610 kg

Operating temperature (housing) -5 to 50 °C/23 to 122 °F

Storage temperature -20 to 60 °C/-4 to 140 °F

Operating conditions

Standard reference EU guideline 2004/108/EC

Technical data testo 6381

Resolution humidity 0.1 %RH

Temperature resolution 0.01 °C / °F

Load max. 500 Ω

Quantity Standard: 1; for humidity/temperature(optional): 3

* Measurement inaccuracy according to GUM: ±0.8% of measurement range finalvalue ±0.3 Pa

GUM (Guide to the Expression of Uncertainty in Measurement): ISO guideline forthe determination of measurement inaccuracy, in order to make measurementresults internationally comparable. The following inaccuracies are used for the determination:Hysteresis / Linearity / Reproduceability / Long-term stability / Adjustmentsite/factory calibration / Test site

testo 6381 – Product Specifications

see complete listing p. 6

netzerotools.com

netzerotools.com

Page 12: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

8

Configuration options testo 6351:

testo 6351– Major features andbenefits

· Measurement of differential pressure, flowvelocity and volume flow

· Automatic zero-point adjustmentguarantees temperature-independentaccuracy and long-term stability

· Rugged plastic housing

· Display with multi-language operatingmenu and visual alarm display

· Ethernet, relay and analog outputs allowoptimum integration into a range ofautomation systems

· The P2A software for Programming,Adjustment and Analysis saves time andcosts in commissioning and maintenance

· Scalable measuring range by ±50 percent

of the measuring range final value, and freescalability within the measuring range,allows optimum adaptation to demandingcontrol requirements

Typical applications

· Differential pressure monitoring betweencleanroom zones

· Differential pressure monitoring in fillingprocesses

· Monitoring differential pressure, volumeflow and flow velocities in critical airconditioning technology (cVAC systems)

B02B03B04B05B06

C00C02C03C04C05

K01K02K03

D01D02D03

H00H01H02

F01F02F03F04F05F06F07F08F09F10F11F12F13F14F15F16

0 to 1 V (4-wire, 24 VAC/DC)0 to 5 V (4-wire, 24 VAC/DC)0 to 10V (4-wire, 24 VAC/DC)0 to 20 mA (4-wire, 24 VAC/DC)4 to 20 mA (4-wire, 24 VAC/DC)

without display, without operating buttonswith display, with operating buttons / English with display, with operating buttons / German with display, with operating buttons / Frenchwith display, with operating buttons / Spanish

Cable input M16 (relay: M20)Cable entry NPT 1/2“Cable contact via M-plug connection forsignal and supply

Pa / min / maxhPa / min / maxkPa / min / maxmbar / min / maxbar / min / maxmmH2O / min / max mmH2O / min / max inch HG / min / maxkg/cm² / min / maxPSI / min / maxm/s / min / maxft/min / min / maxm³/h / min / maxl/min / min / maxNm³/h / min / maxNl/min / min / max

without relay4 relay outputs, limit value monitoring4 relay outputs, channel 1 limit values and collective alarm

German/English instruction manualFrench/English instruction manual Spanish/English instruction manual

Order no. 0555 6351 A01 Bxx Cxx Dxx Exx Fxx Hxx Ixx Jxx Kxx

E00E01

without Ethernet module with Ethernet module

Axx Measuring rangeBxx Analog display/supplyCxx DisplayDxx Cable inputExx Ethernet

A02A03A04A05A07A08A09A10A11A22A23A24A25A27A28A29A30A31

0 to 802 in. water (0 to 2000 hPa)

Scaling: ±50%of measuringrange; freelyselectablewithinmeasuringrange

Fxx Differential pressure/flow velocity unit (pre-set)Hxx RelayKxx IM languages (for bilingual printed IMs)

This results in a typical ordering code:0555 6351 AXX BXX CXX DXX EXX FXX HXX IXX KXX

testo 6351- Differential pressure for normal zones

· Self-monitoring ("Early Warning) system in thetransmitter ensures maximum uptime

0 to 0.2 in. water (0 to 50 Pa) 0 to 0.4 in. water (0 to 100 Pa) 0 to 2 in. water (0 to 500 Pa)

0 to 20 in. water (0 to 50 hPa)0 to 40 in. water (0 to 100 hPa)0 to 200 in. water (0 to 500 hPa)

0 to 4 in. water (0 to 10 hPa)

0 to 401 in. water (0 to 1000 hPa)

- 802 to 802 in. water (- 2000 to 2000 hPa)

- 0.2 to 0.2 in. water (- 50 to 50 Pa) - 0.4 to 0.4 in. water (- 100 to 100 Pa) - 2 to 2 in. water (- 500 to 500 Pa)

- 20 to 20 in. water (- 50 to 50 hPa)- 40 to 40 in. water (- 100 to 100 hPa)- 200 to 200 in. water (- 500 to 500 hPa)

- 4 to 4 in. water (- 10 to 10 hPa)

- 401 to 401 in. water (- 1000 to 1000 hPa)

Note: 4-wire installation required

netzerotools.com

netzerotools.com

Page 13: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

9

testo 6351

Supply

Display

Differential pressure Analog outputs

Other outputs

Housing

Miscellaneous

Display Optional: 3-line LCD with multi-languageoperating menu

Parameters

Measuring range 0 to 50 Pa0 to 100 Pa0 to 500 Pa0 to 10 hPa0 to 50 hPa0 to 100 hPa0 to 500 hPa0 to 1000 hPa0 to 2000 hPa

-50 to 50 Pa-100 to 100 Pa-500 to 500 Pa-10 to 10 hPa-50 to 50 hPa-100 to 100 hPa-500 to 500 hPa-1000 to 1000 hPa-2000 to 2000 hPa

Measurement uncertainty* ±0.8% of measurement range final value±0.3 Pa

Meas. cycle 1/sec

Resolution 12 bit

Scaling Differential pressure: scalable ±50% ofmeasuring range final value; freely scalable within measuring range

Overload capacity Measuring range Overload0 to 50 Pa 20000 Pa0 to 100 Pa 20000 Pa0 to 500 Pa 20000 Pa0 to 10 hPa 200 hPa0 to 50 hPa 750 hPa0 to 100 hPa 750 hPa0 to 500 hPa 2500 hPa0 to 1000 hPa 2500 hPa0 to 2000 hPa 2500 hPa-50 to 50 Pa 20000 Pa-100 to 100 Pa 20000 Pa-500 to 500 Pa 20000 Pa-10 to 10 hPa 200 hPa-50 to 50 hPa 750 hPa-100 to 100 hPa 750 hPa-500 to 500 hPa 2500 hPa-1000 to 1000 hPa 2500 hPa-2000 to 2000 hPa 2500 hPa

Inputs/outputs

Output type 0/4 to 20 mA (4-wire) (24 VAC/DC)0 to 1/5 to 10 V (4-wire) (24 VAC/DC)

Relay Optional: 4 relays (free allocation tomeasurement channels or as collectivealarm in operating menu/P2A software), upto 250 VAC/3A (NO or NC)

Voltage supply 20 to 30 VAC/DC, 300mA currentconsumption, galvanically separatesignal and supply line

General technical data

Material Plastic housing

Dimensions 162 x 122 x 77 mm

Resolution pressure Measuring range Resolution0 to 50 Pa 0.1 Pa0 to 100 Pa 0.1 Pa0 to 500 Pa 0.1 Pa0 to 10 hPa 0.01 hPa0 to 50 hPa 0.01 hPa0 to 100 hPa 0.1 hPa0 to 500 hPa 0.1 hPa0 to 1000 hPa 1 hPa0 to 2000 hPa 1 hPa-50 to 50 Pa 0.1 Pa-100 to 100 Pa 0.1 Pa-500 to 500 Pa 0.1 Pa-10 to 10 hPa 0.01 hPa-50 to 50 hPa 0.01 hPa-100 to 100 hPa 0.1 hPa-500 to 500 hPa 0.1 hPa-1000 to 1000 hPa 1 hPa-2000 to 2000 hPa 1 hPa

Protection class IP 65

Selectable units Pa, further pressure and flow velocityunits see configuration options p. 8

Sensor Piezoresistive sensor

Automatic Zero-pointadjustment

via magnetic valve, frequency settable:15 sec, 30 sec, 1 min, 5 min, 10 min

Digital output Mini-DIN for P2A software

Ethernet Optional with Ethernet module

Weight 0.7 kg; optional: Ethernet layer: 0.6 kg

Operating temperature (housing) -5 to 50 °C/23 to 122 °F

Storage temperature -20 to 60 °C/-4 to 140 °F

Operating conditions

Standard reference EU guideline 2004/108/EC

Load max. 500 Ω

Technical data testo 6351

Quantity 1

* Measurement inaccuracy according to GUM: ±0.8% of measurement range finalvalue ±0.3 PaGUM (Guide to the Expression of Uncertainty in Measurement):ISO guideline for the determination of measurement inaccuracy, in order to makemeasurement results internationally comparable. The following inaccuracies are used for the determination:– Hysteresis– Linearity– Reproducibility– Long-term stability– Adjustment site/factory calibration– Test site

testo 6351 – Product Specifications

see complete listing p. 8

netzerotools.com

netzerotools.com

Page 14: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

External probes for testo 6383 and testo 6381 – testo Series 6610 probes

10

testo 6611* testo 6612 testo 6613 testo 6614 testo 6615 testo 6617

Type Wall

%RH; °Ctpd/°Ftpd; g/m³ / gr/ft³; g/kg / gr/lb; kj/kg; BTU/lb; °Ctw/°Ftw;hPa; inch H2O2; ppm vol %; %vol; °Ctm (H2O2)/ °Ftm(H2O2)

Stainless steel

Sheathed, FEP

ABS plastic

Channel Cable

-30 to +150 °C, -22 to +302 °F

see trace humidity 0 to 100 %RH

Heated cable Trace humiditycable (self-adjustment)

Cable withcovering electrodemonitoring

200 mm 200/500 mm200/300/500/800 mm

Customized forduct version

1 to 10 bar (probe tip)1 bar (probe end)

1 to 16 bar (probe tip)1 bar (probe end)

1 bar positivepressure (probe tip)1 bar (probe end)

Selectable units

0 to 100 %RH

-20 to +70 °C, -4 to +158 °F

Measuring range

Temperature

Probe shaft

Cable

Connector

±0.15 °C / 32.2 °F (Pt 1000 1/3 Class B)Measurement inaccuracy ** (at 25 °C / 77°F)

Indoor climateprobe wallinstallation

Process humidityprobe, ductinstallation

Process humidityprobe, flexibleinstallation withcable

Humidity probe forhigh humiidityapplications/fordanger ofcondensation

Humidity probe fortracehumidity/pressure dewpoint (with self-adjustment)

Humidity probe withself-monitoring forsensor-damagingmedia

Probe shaft diameter 12 mm

Probe shaft length

Cable length 1/2/5/10 m

Process pressure 1 bar positive pressure (probe tip)

120/200/300/500/800 mm

±1 K at 0° Ctd±2K at -40° Ctd±4K at -50° Ctd

-40 to +180 °C/-40 to +356 °F -40 to +120 °C, -40 to +248 °F

-40 to +180 °C /-40 to +356 °F

±0.15 °C / 32.2 °FPt1000 1/3 Class B

±0.15 °C / 32.2 °FPt100 1/3 class B

Humidity

±1.0 %RH (0 to 90%); ±1.4 %RH (90 to 100%)Measurement uncertainty** (25 °C)

0.02 %RH/KMeasurement inaccuracy (for deviationsfrom media temperature of ±25 °C)

Temperature

°C / °FSelectable units

better than 0.2 %RHReproduceability

Trace humidity-60 to +30 °Ctd /-76 to +86 °Ftd

Measuring range

Measurement uncertainty

Probe

Application

Parameters

General technical data

Operating conditions

* Technical data also apply to the integrated humidity probe of the testo 6383. testo 6611 probe cannot be connected to the testo 6383.

see trace humidity±1.0 %RH(0 to 100%)

±1.2 %RH (0 to 90%);

±1.6 %RH (90 to 100%)

** DDeetteerrmmiinnaattiioonn ooff hhuummiiddiittyy mmeeaassuurreemmeenntt iinnaaccccuurraaccyy aaccccoorrddiinngg ttoo GGUUMMGUM (Guide to the Expression of Uncertainty in Measurement):

ISO guideline for the determination of measurement inaccuracy, in order to makemeasurement results internationally comparable. The following inaccuracies are used for the determination:– Hysteresis– Linearity– Reproducibility– Long-term stability– Adjustment site/factory calibration– Test site

netzerotools.com

netzerotools.com

Page 15: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Configuration options testo Series 6610 probes

11

L11 L12 L13 L14 L15 L17

– – X – – –X X X X X X– X X – – –– X X X X X– X X – – –

Ordering procedure:Thanks to the digital probe interface, the transmitter and the probe can be ordered separately from each other, see ordering example above.

0555 6610 Lxx Mxx

L11L12L13L14L15L17

Probe 6611 (wall version)Probe 6612 (duct version up to 150 °C)Probe 6613 (cable version up to 180 °C)Probe 6614 (heated cable version)Probe 6614 (heated cable version)Probe 6617 (self-monitored cable version)

M01M02M03M04M06M07M08

Sintered stainless steel filterMetal wire protection capSintered Teflon filterOpen metal protection capTeflon filter with drip holeTeflon filter with drip hole and condensation protectorFilter for H2O2 atmospheres*

N00N01N02N05N10N23

without cableProbe length 1 mProbe length 1 mProbe length 5 mProbe length 10 mProbe length, specially for duct versions

P12P20P30P50P80

Probe length 300 mmProbe length 200 mmProbe length 300 mmProbe length 500 mmProbe length 800 mm

Nxx Pxx

Ordering example for testo 6613 probe:

Cable probe, -40 to +180 °C

Sintered stainless steel filter

Cable length 2 m

Probe length 300 mm

0555 6610 L13 / M01 / N02 / P30

specially for high humidity (testo 6614 only)

L11 L12 L13 L14 L15 L17

X – – – – –– – X X X X– – X X X X– – X X X X– – X X X X– X – – – –

* H2O2 processes:Testo offers a transmitter which can also be used in hydrogen peroxide (H2O2) processes - e. g. in sterilization. The sensor is protected withthe help of a special probe (Code M08). In addition, the so-called " mixture dewpoint“ °Ctm/°Ftm is calculated and displayed.

Probeconnector

Probe length

Probe length

Probe

Filter

Ordering number

results in Order number:

netzerotools.com

netzerotools.com

Page 16: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

12

Accessories for all transmitters

Power supply 110 to 240 VAC / 24 VDC (350 mA) 0554 1748

Power supply rail mount 90 to 264 VAC / 24 VDC (2.5 A) 0554 1749

Process display testo 54-2 AC, two relay outputs (to 250 VAC / 300 VDC, 3A), power supply 90 to 260 VAC 5400 7553

Process display testo 54-7 AC, two relay outputs (to 250 VAC / 300 VDC, 3A), power supply 90 to 260 VAC,with RS485 output for online monitoring and with totalizer display 5400 7555

Ethernet module field installable (for testo 6351 and testo 6381 only) 0554 6656

Ethernet plug (for testo 6351 and testo 6381 only) 0554 6653

P2A software (Programming, Adjustment, Analysis) incl. USB adapter 0554 6020

Silicon hose ID 4 , transparent, 1 m 0086 0001

Tygon hose ID 4.8 , transparent, 1 m 0086 0031

Humidity adjustment set 11.3 / 75.3 %RH (for testo 6381 and testo 6383 only) 0554 0660

Adjustment and extension cable, 10 m (for testo 6381and testo 6383 only) 0554 6610

Pitot tube, length 350 mm, stainless steel (for testo 6351 and testo 6381 only) 0635 2145

Pitot tube, length 1000 mm, stainless steel (for testo 6351 and testo 6381 only) 0635 2345

Ordering data for accessories Part no.

Ethernet module(Intermediary layer)

Ethernet

The Ethernet module is anintermediary layer (field installdesign), which can be optionallyintegrated into the transmitterstesto 6681/6351. It can beeither factory installed orquickly retrofitted on site. TwoLEDs provide the responsiblesystem operator with informationon the status of the voltagesupply and the LAN connection.

The cable can be used to carryout an adjustment of a humidityprobe from the testo 6610 Series- either on site or in a metrologylaboratory. The cable also servesas an extension between thetransmitter and the respectiveprobe.

Advantages of the adjustment

By using an industrial Ethernetplug, IP65 housing protection canbe guaranteed, enabling thetransmitter to withstand thesometimes rough and demandingconditions in industrial processes.

and extension cable:

– Flexible installation andmaintenance of the humidityprobe

– Extension of the normalhumdity probe cable by 32 ft (10 m)

– Cable has protection classIP65

1

Ethernet module for testo 6381/6351

2

32 ft Adjustment and extension cable for external humidity probes

As with any communication system,it is recommended that IT personnelbe involved in the installation andcommissioning of the Ethernet module.

Note: 4-wire installation required forthis option.

netzerotools.com

netzerotools.com

Page 17: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Additional Testo transmitters for the outside zone

13

testo 6321Differential pressure

testo 6621Temperature/RH

testo 6920Temperature

" On the wall" calibration solutions from Testo

testo 400* withprecision temp &

Pneumator*differential pressure

Huminator*temperature/RH

Housing standard plastic housing standard plastic housing standard plastic housing

Measuring Range (typical range)* 0 to 4" w.c. (0 to 10 hPa) 32 to 140 F (0 to 60 C) 32 to 158 F (0 to 70C) wall

Output 0 to 1/5/10V 4-wire, 24VAC/DC 0 to 1/5/10V 4-wire, 24VAC/DC 0 to 1/5/10V 4-wire, 24VAC/DC

Display Optional Optional Optional

Units (min/max) Pa, hPa, kPa, mbar, bar, psi F, C, %RH F, C

" Auto-Zero" function included as Wall or Duct version available Wall or Duct version availableStandard

RH probe

0 to 100% RH -4 to +158 F (-20 to 70 C) duct

* Consult individual product literature for full measuring ranges of each instrument, or contact Testo Customer Service at 1-800-227-0729

4 to 20mA 4-wire, 24VAC/DC 4 to 20mA 2-wire, 24VDC 4 to 20mA 2-wire, 24VAC/DC

mmH2O, in. H2O, in. Hg, kg/cm2,

Accuracy 1.2% of measuring range 0.5 C, 2.5% RH± ± ± ± 0.5 C

Typical installation site in

cleanroomCritical zone: wall mountinstallation on cleanroom wall

Normal zone or outside zone

Normal zone or outside zone

calibrator

*

Huminator shown with testo 400 andprecision T/RH probe

The testo Huminator allows you toindependently vary both humidity &temperature for both fixed andhandheld probes

Its unique inductive sensor yieldshigh accuracy ( 0.3% of scale), zero point stability, and protectiveoverload protection

±Calibrate your transmitter probesfor both temperature and RHwithout powering down, removalor disassembly

testo 400 with precision probe and data connection cable

The testo Pneumator can operate asboth a reference instrument and afield instrument

±

netzerotools.com

netzerotools.com

Page 18: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

14

Moisture management in compressed air systems

testo 6740Series Pressure testo 6781

Pressure Dew point

Compressed air dewpoint measurement accessories

testo 6721Dew point switch transmitter

Dew Point transmitter

Housing plastic, polyacrimid standard plastic housing metal housing

Measuring Range -60 to +30 C tpd (0 to 50 C) -30 to +30 C tpd (-22 to +86 F tpd) -90 to -20 C tpd

Output 4 to 20mA, 2-wire, user scalable pressure dewpoint (Ctpd or Ftpd)

Display Optional Optional Optional

Output Units Ctpd, Ftpd, CtA (atm. dewpoint), C tpd, F tpd C tpd, F tpd, %RH, C tdA, F tdA,

1/2" NPT connection standard

FtA, %RH, ppm(v), mg/m3, C, F ppm(v), g/m3, g/ft3, g/kg, g/lb

Accuracy 0.5 K (0 to 50 C)± ±

Typical application Granulate drying, compressedair systems, critical air systems

via keypad on optional display

Part no. 0555 6741/2/3/4 0555 6721 0555 6781

1/2 G conn. for accessories1/2" NPT connection standard

refrigeration dryers

3 K at -30C tpd,± 1 K at +10C tpd

over two switch outputs

1/2" NPT connection standard auto-adjusting and self-monitoring

trace humidity monitoring downto -90 C tpd

3 K (-75 to -90 C tpd),±2 K (-60 to -40 C tpd),±1 K (-40 to -10 C tpd)±

0 to 20, 4 to 20 mA (4-wire)

1/2 G conn. for accessories

Pre-filter is additionally used forcontaminated air and when processpressure corresponds to pre-setting ofprecision measurement chamber

For dry air (e.g. granulate dryers, max.140 °C), a Teflon tube is additionally usedand the valve of the measuring chamberis opened fully (suitable down to -60 °C )td

Use of precision measurement chamberfor clean air and when process pressurecorresponds to pre-setting

A

B

C

D

E

Flow meter is additionally usedwhen air is clean and process pressuredeviates from pre-setting of precisionmeasurement chamber (1 to 35 bar)

The cooling coil is additionally used forprocess temperatures >50°C (to 200°C)and process pressure corresponding tothe pre-set of the measurement chamber

to dp

transmitter

netzerotools.com

netzerotools.com

Page 19: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

15

Testo – Your partner for calibration

testo SaverisTM – multi-point Wireless and/or Ethernet monitoring and alarming

Calibration:NIST and ISO cals for temperature, humidity andpressure are available for all Testo transmitters.Contact Testo for more information on calibrations and adjustments to suit your

Calibration services from Testo

Saveris measures macro or micro environmental pressure, temperature and humidity valuesIn critical processes, exacttemperatures, humidity values andpressure relationships play a crucialrole. Saveris collects, securely storesand delivers this data wirelesslyor via Ethernet. Programmable alarms can be usedto quickly alert responsible personnelwhen critical values drift. Saveriscan also operate under 21CFR11.

Typical applications:

• Ambient production, lab andwarehouse monitoring

• Environmental chamber temp and

• Monitoring temperatures andhumidities in critical control areasserved by critical VAC systems

Integrate Testo transmitters into testo Saveris - control and data management in one systemTM

specific process or environmental requirements.

Testo maintains calibration capabilities fortemperature, pressure, humidity and velocity, with supplemental capabilities in sound andlight. Combustion product capabilities include O 2, CO, NO and SO2. Standard, custom, and prime levels of calibration are provided.

TM

humidity monitoring

TM

TM

netzerotools.com

netzerotools.com

Page 20: Differential Pressure, Temperature and Humidity Monitoring€¦ · Differential Pressure, Temperature and Humidity Monitoring ... Testo 0602 0193 Saveris Leaf Surface Probe Thermocouple

Sub

ject

to c

hang

e w

ithou

t not

ice.

Request more information:Monitoring Instruments for Food Production, Transport and StorageMeasurement Engineering for Restaurants, Catering andSupermarketsMeasurement Engineering for Air Conditioning and Ventilation Measurement Engineering for Heating and InstallationMeasurement Solutions for Emissions, Service and ThermalProcessesMeasurement Solutions for Refrigeration TechnologyStationary Measurement Solutions for Air Conditioning, Drying,Cleanrooms and Compressed AirMeasurement Solutions for Production, Quality Control andMaintenanceMeasurement Solutions for Climate Applications in IndustryReference Measurement Technology for Industry

Measuring Instruments for TemperatureMeasuring Instruments for HumidityMeasuring Instruments for VelocityMeasuring Instruments for Pressure and RefrigerationMulti-Function Measuring InstrumentsMeasuring Instruments for Flue Gas and EmissionsMeasuring Instruments for RPM, Analysis, Current/VoltageMeasuring Instruments For Indoor Air Quality, Light And SoundStationary Measurement Technology Humidity / DifferentialPressure / Temperature / Process DisplaysStationary Measurement Technology Compressed Air Humidity /Compressed Air Consumption