• No calibration necessary • No setup procedure required Results in 4 seconds taking the average of 250 readings Distributed by i-Pen ® is an in vivo , point-of-care, diagnostic testing device designed to detect and measure elevated tear osmolarity levels associated with mild, moderate & severe Dry Eye Disease. Diagnose Dry Eye Disease RAPID ACCURATE ECONOMICAL Note: The i-Pen ® is an in vivo testing device that is used to measure tear osmolarity levels (in situ) directly on the surface of the eye. No tear fuild samples are extracted from the eye in order to perform the test. easily and effectively REVOLUTIONARY NEW PRODUCT AVAILABLE NOW!

Diagnose Dry Eye Disease - Designs For Vision · moderate & severe Dry Eye Disease. Diagnose Dry Eye Disease RAPID ACCURATE ECONOMICAL Note: The i-Pen® is an in vivo testing device

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Diagnose Dry Eye Disease - Designs For Vision · moderate & severe Dry Eye Disease. Diagnose Dry Eye Disease RAPID ACCURATE ECONOMICAL Note: The i-Pen® is an in vivo testing device

• No calibration necessary• No setup procedure required• Results in 4 seconds taking

the average of 250 readings

Distributed by

i-Pen® is an in vivo, point-of-care, diagnostic testing device designed to detect and measure elevated tear osmolarity levels associated with mild, moderate & severe Dry Eye Disease.

Diagnose Dry Eye Disease

RAPID ACCURATE ECONOMICAL

Note: The i-Pen® is an in vivo testing device that is used to measure tear osmolarity levels (in situ) directly on the surface of the eye. No tear fuild samples are extracted from the eye in order to perform the test.

easily and effectively

REVOLUTIONARY NEW PRODUCT AVAILABLE NOW!

Page 2: Diagnose Dry Eye Disease - Designs For Vision · moderate & severe Dry Eye Disease. Diagnose Dry Eye Disease RAPID ACCURATE ECONOMICAL Note: The i-Pen® is an in vivo testing device

The LCD will display a test result.

TAKING A READING

EJECT THE SINGLE USE SENSOR

EXPECTED RESULTS

i-Pen® test results are displayed on the LCD in units of mOsms/L. No calculations are required. The illustration below shows some typical test results and their possible interpretation. All such interpretation is subject to the review of the physician or other medical professional.

REMOVE THE SINGLE USE SENSOR FROM PACKAGE

1. Tear along the dotted line to separate the attached 1 , wrapped Single Use Sensors.

2. Grasping the bottom firmly with one hand 2 , with the other tear in the direction of the pre-cut section to expose the end of the Single Use Sensor 3 to be inserted into the i-Pen® device.

INSERT THE SINGLE USE SENSOR

First 1 remove the unit cover, then 2 insert the disposable Single Use Sensor and DO NOT TOUCH THE GOLD NODES or the tip - sterile

Instructions for Use

You may now discard the Single Use Sensor.

1 Push the Ejector button and the Single Use Sensor will be ejected.

2 31

DRY EYE SEVERITY SCALE

275 290 305 320 335 350 365 380 400

Normal Mild Moderate Severe

REFERENCE TEAR OSMOLARITY VALUES

Marking by the CE symbol indicates compliance of this device as a Class 1 medical device with a measuring function, with the Medical Device Directives 93/42/ EEC as amended by 2007/47/CE.

IPENIFUE0916

QUESTIONS? COMMENTS?

Customer satisfaction is an I-MED Pharma Inc. priority. To help us in providing you with the best possible product and support, please send us your comments and suggestions.

[email protected]

21

1

1 Ask the patient to gently squeeze their eyelids shut for 30-60 seconds prior to taking a reading.

3 Turn on the i-Pen® as indicated by pressing the main button.

2 Position the tip of the disposable Single Use Sensor just above the lower eyelid with the LCD screen facing upwards.

4 Approach at a 30-45 degree angle from horizontal and gently lower the end of the Single User Sensor on to the conjunctiva on the inside of the lower eyelid.

6 The i-Pen® will make an audible beep after several seconds and display the reading on the LCD screen.

5 When correctly placed, the tip of the Single Use Sensor should be depressing the surface slightly so that both gold nodes are in good contact with the conjunctiva.

Range of Values Mean Value

Normal Patients 275-316 mOsms/Lw 300 mOsms/L

Dry Eye Disease Patients

>300 mOsms/L 327 mOsms/L

1300 73 73 93 02 8814 6811

www.insightsurgical.com.auORDER NOW

Normal< 290

Marginal290-310

Mild310-330

Moderate330-350

Severe> 350

DRY EYESEVERITY