DESIGN/DEVELOPMENT REVIEW COMMISSION February 9, 2017 at 4:00pm
City Council Chambers, 3rd Floor, 1737 Main Street, Columbia, SC 29201
Site Plan Review Case Summary 5000 Vista Towers Drive, TMS#09011-15-01
Council District: 2
Proposal: Conversion of an office building into 23 apartments
Applicant: Wes Lyles, AIA, LEEP AP, Studio 2LR, Inc.
Proposed Use: Apartments
Staff Recommendation: Approval with staff comments.
Detail: This project entails the renovation of a three-story, ± 42,102 sq. ft. office building into 23 apartments. The site is 7.56 acres and currently contains four towers with 512 apartment units. After the renovation of the office building, the total number of apartments on the property will be 555. The required number of off-street parking spaces for the entire property is 555 whereas the plans to provide 481 by seeking a variance from the Board of Zoning Appeals. Should the Commission be inclined to grant approval of the site plan, staff would request that the Commission grant approval subject to staff comments.
CITY REVIEWING AGENCY COMMENTS John Fellows, Planning Recommend approval. K. Brian Cook, Zoning Administrator
Recommend approval with condition: 1. Must obtain a parking variance from the Board of Zoning Appeal.
Johnathan Chambers, Land Development Administrator Recommend approval. Jerry Thompson, Building Official Recommend approval with condition:
1. Must comply with all applicable building codes. Scott Rogers, Utilities Recommend approval with conditions:
1. Any needed upgrade, extension or relocation of City utilities must be provided by the developer.
2. Any privately owned/maintained utilities or permanent structures cannot be located inside City of Columbia utility easements.
3. Water mains, sewer mains, water meters that are 4” or larger or any privately maintained utilities will not be allowed inside public right-of-ways or under sidewalks without an approved encroachment permit and written approval from the City Engineer. Coordination between the Civil Engineer, Architect and Mechanical Engineer to allow room for these utilities on the developed property is strongly encouraged.
PAGE 1 OF 2
4. If sewer flows for this project result in flows of 4,000 gallons per day or above calculations must be submitted to the City's Engineering department to determine how the proposed project will affect the City’s sewer system. Depending upon the effects of the projected flows this project may or may not be approved. If required, these calculations should be submitted to the Engineering department as soon as possible.
David Brewer, Traffic Engineering Recommend approval. Kris Scott, Fire Department Recommend approval. Sara Hollar, Forestry Recommend approval. Mike Jaspers, Stormwater Recommend approval with conditions:
1. Development must comply with all applicable land disturbance requirements.
David Knoche, Parking Recommend approval.
Robert Sweatt, Street Division Recommend approval with condition: 1. ADA requirements must be met.
John Hooks, Solid Waste Recommend approval.
Scott Holder, Landscaping Recommend approval. 1. No landscape plan provided. 2. Any existing landscape used for compliance removed during
construction should be replaced.
PAGE 2 OF 2
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID,IGN, and the GIS User Community
/
0 390 780195 Feet
CITY OF COLUMBIA GIS DATA DISCLAIMER
The City of Columbia GIS data represented on this map or plan is the product of compilation, as produced by others. It is provided for informational purposes
only and the City of Columbia makes no representation as to its accuracy. Its use without field verification is at the sole risk of the user.
Friday, November 11, 2016
City of Columbia5000 Thurmond Mall
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID,IGN, and the GIS User Community
/
0 390 780195 Feet
CITY OF COLUMBIA GIS DATA DISCLAIMER
The City of Columbia GIS data represented on this map or plan is the product of compilation, as produced by others. It is provided for informational purposes
only and the City of Columbia makes no representation as to its accuracy. Its use without field verification is at the sole risk of the user.
Friday, November 11, 2016
City of Columbia5000 Thurmond Mall
FORM REVISED 02/10
City of Columbia
APPLICATION for
SITE PLAN/SUBDIVISION PLAT REVIEW
OFFICE USE ONLY: Date Received ______________ By ____________________________________________
1) APPLICANT (Please Print) Name: Company:
Tel. #: Fax#: Mobile #: E-mail: Do you own any of the property affected by this application? YES NO; If NO, provide Letter of Agency
Group/Individual Commercial Development
Group Residential Development
Residential Subdivision
Planned Unit Development Site Review
2) THIS APPLICATION IS FOR (Check all that apply)
3) PROPERTY Address: TMS#: Total Acreage: Current Use: Proposed Use: Current Zoning: Number of Lots and/or Units: Total Sq. Ft.
3) DETAILED PROJECT DESCRIPTION: (Attach additional paper if you need more space)
4) NEIGHBORHOOD CONSULTATION
Prior to the Planning Commission meeting, meet with the adjacent neighbors or neighborhood association to communicate details of the proposed project. Please note that this informational meeting is not required by ordinance, but is strongly encouraged. Contact information may be obtained from Zoning staff.
5) PLAN SUBMITTAL Please refer to the Checklist for Site Plan Review for materials required for submittal with this application
6) SIGNATURE Applicant Signature:
Print Name: Date: PC Date: Action:
E
EMH
NTN
S48°01
'56"W 2
67.94'
TIE LINE
POOL
CONCRETE BLOCKCARPORT
CONCRETE BLOCK
CARPORT
GAZEBO
CONCRETE BLOCK
GARAGE
22.0'
57.0'
100.7'
56.7'
22.0'
21.9'
56.8'
21.9'
100.8'
56.7'
22.1'
21.9'
56.7'
22.0'
22.1'
56.7'
100.6'
56.7'
21.6'
22.1'
56.5'
21.9'
22.2'
56.7'
56.7'
22.0'
22.0'
21.9'
22.1'
56.7'
100.7'
56.7'
209.4'
62.6'
209.4'
62.6'
EXECUTIVE CENTER
MOPED PARKING
TPED
TP
20'
15' CITY OF COLUMBIASANITARY SEWER
EASEMENTPER DEED BOOKD1122, PAGE 504
20'
15' CITY OF
COLUMBIA
WATER LINE
EASEMENT
PER DEED BOOK
D1122, PAGE 500
15' CITY OF COLUMBIASANITARY SEWER
EASEMENTPER DEED BOOKD1122, PAGE 504
30' CITY OF COLUMBIASTORM DRAINAGE EASEMENT
PER DEED BOOKD1122, PAGE 507
20' CITY OF COLUMBIASTORM DRAINAGE EASEMENT
PER DEED BOOKD1122, PAGE 507
15' CITY OF
COLUMBIA
WATER LINE
EASEMENT
PER DEED BOOK
D1122, PAGE 500
30'
9' SCE&GGAS LINE
EASEMENTPER DEED BOOKD836, PAGE 143
POWERLINE
EASEMENT
PER PLAT BOOK
51, PAGE 4833
POWERLINE
EASEMENT
PER PLAT BOOK
51, PAGE 4833
MANHOLE
NOT
FOUND
APPROXIMATE LOCATION10" SANITARY SEWER
PER REFERENCE NO. 6(UNABLE TO FIELD
VERIFY)
10' SCE&G UNDERGROUND
ELECTRIC EASEMENTPER DEED BOOKD887, PAGE 496
30'
WROUGHT
IRON
FENCE
WROUGHT
IRON
FENCE
15' CITY OF
COLUMBIA
WATER
LINE EASEMENT
PER DEED BOOK
D1122, PAGE
500
95
OVERHEAD SIGN
VALVEPIT
PLANTER
STEPS
STEPSCALL
BOX
RAMP
RAMP
GATE
STEPS
DUMPSTE
RPAD
PLANTER
PLANTER
PLANTER
PLANTER
PLANTER PLANTER
PLANTER
PLANTER
OVERHANG
PLANTER
PLANTER
PLANTER
RAMP
RAMP
RAMP
PLANTER PLANTERGATE GATE
SIGNS
126.4'
134.1'
78.1'
118.6'
149.1'
DUMPSTE
RPAD
LOWER
LEVEL
ENTRANCE
UPPER
LEVEL
ENTRANCE
POINT OFBEGINNING
FLAG POLES
SIGNSIGNSIGN
SIGNSIGNSIGNSIGN
SIGNSIGNSIGNSIGN
SIGN
SIGN
SIGN
SI GN
GRASS
GRASS
GRASS
GRASS GRASS GRASS
GRASSGRASS
GRASSGRASS
GRASS
END OF
PAVEMEN
T
CONCRETE SIDEWALK CONCRETE SIDEWALK
APPROXIMATE LOCATION
GATE
BELLSOUTH
TELEPHONE
BOX
STUCCO WALLSTUCCO WALL
OVERHANG
(TYPICAL)
89.6'
STEPS
OVERHANG
423'± TO RICHLA
ND STREET
CURB LINE
HIGHWAY R/W
HIGHWAY R/W
OVERHANG
(TYPI CAL)
30.7'
2.8'
3.7'
CABLE TVBOX
BUILDING HEI GHT=
1 4.36'
(STATE MAINTAINED)
(STATE MAINTAINED)
(STATE MAINTAINED)
POINT OF COMMENCEMENTPK NAIL AT ℄ INTERSECTIONOF WAYNE ST. & ELMWOOD
AVE.
(VIADUCT)
CP
(PUBLIC)
3.6'
3.7'
ENCROAC
HMENT
ENCROAC
HMENT
60"RCP
GAS
RELIEF
STATION
CITY OF COLUMBIA(TMS# R09011-14-05)
LANDSMENASSOCIATES, LLC(TMS# R09010-02-04)
PAVILION LAND PARTNERSHIP, LP(TMS# R09010-02-01)
WELL BUILT PROPERTIES, LLC(TMS# R09010-01-
S. C. ASSOCIATION OF COUNTIES(TMS# R09010-01-
PAVILION LA
ND
PARTNERSHIP LP
(TMS# R09010-02-03)
ELMWOOD AVENUE U. S. HIGHWAY 21, 176 &
HUGER STREET
7-STUCCO BUILDINGFIRST FLOOR SQUARE
FOOTAGE = 6,954 SQ.FT.
BUILDING HEIGHT=87.93'
MULTI-LEVELBRICK BUILDINGFIRST FLOOR SQUARE
FOOTAGE = 13,100 SQ.FT.
BUILDING HEIGHT=
33.06'
8-STUCCO BUILDINGFIRST FLOOR SQUARE
FOOTAGE = 6,952 SQ.FT.
BUILDING HEIGHT=96.60'
8-STUCCO BUILDINGFIRST FLOOR SQUARE
FOOTAGE = 6,955 SQ.FT.
BUILDING HEIGHT=92.50'
8-STUCCO BUILDINGFIRST FLOOR SQUARE
FOOTAGE = 6,968 SQ.FT.
BUILDING HEIGHT=92.11'
SINGLE-STORY
STUCCO BUILDING
PULA
SKI STREET (S-40-
(BITUMINOUS PAVEMENT) (100' R/W)
CALH
OUN STREET
(S-40-
(BITUMINOUS PAVEMENT)
(CITY MAINTAINED) (100' R/W)
(PUBLIC)
MULTI-LEVELPARKING GARAGE
BUILDING HEIGHT=17.17'
FIRST FLOOR HAS 48 SHARED PARKING SPACES FROM
8 AM AND 5 PM EXCLUSIVELY FOR OFFICE PARKING
AND FROM 5 PM TO 8 AM EXCLUSIVELY FOR
APARTMENT PARKING ("SHARED APARTMENT SPACES")
48 SHARED PARKING SPACES FROM 8 AM TO 5 PM EXCLUSIVELY
FOR OFFICE PARKING AND FROM 5 PM TO 8 AM ELUSIVELY FOR
APARTMENT PARKING ("SHARED OFFICE SPACES")
6' CHAIN LINK FENCE
8" CONCRETE WALL
1' CO
NCRET
E WALL
CONCRETE WALL
W/3' METAL HAND
RAIL
6' CHAIN LINK FENCE
1' CONCRETE WAL L
W/WROUGHT IRON FENCE
1' CONCRETE WAL L
W/WROUGHT IRON FENCE
CONTROL
BOX
TRANS.
PAD
GENERATO
RPAD
TRANS.
PAD
TRANS.
PAD
TRANS.
PAD
TRANS.
PAD
TRANS.
PAD
CONC.
PAD
CO
CO
1 2
6
2
8
3
8
73
1
6
3
2
6
1
6
8
9
S63°42'06"W29.80'
S64°30'07"W 81.70'
N39°
58'39
"E
45.78
'
N01°33'50"E
49.20'
N11°43'09"W
48.63'
103.06'
S25°06'10
"E55.94'
S25°22'56"E
260.11'
46.95'
N04°04'34"W
N06°05'50"W
52.19'
48.83'
N07°49'07"W
49.25'
N09°59'12"W
N24°34' 17"W
65. 54'
N58°48'23"E 84.53'
S25°09'43"E
97.44'
N11°23'58"E
50.38'
N20°58'49"E
51.05'
N32°
39'57
"E
47.65
'
48.45'
N14°01'30"W
S64°49'08"W
98.98'
S64°18'02"W 123.16'
53.45'
N64°40'08"E N65°14'11"E 100.00'
213.78'N64°40'07"E
S64°32'36"W 274.56' (TOTAL DISTANCE) 70.50'S64°22'16"W
S25°33'36"E
(63.26') (211.30')
S64°18'02"W19.10'
8.70'
S64°30'07"W142.26'(TOTAL DISTANCE)
90.40'(TOTAL DISTANCE)
5/8"REBAR FOUND
5/8"REBAR FOUND
1-
1/2"PIPE
FOUND
1"PIPE
FOUN
D
1"PIPE
FOUN
D
1"PIPE
FOUN
D
1"PIPE
FOUN
D
1"PIPE
FOUND
(DISTURBED
)
1-
1/2"PIPE
FOUND
1"PIPE
FOUN
D
1"PIPE
FOUN
D
1"PIPE
FOUN
D
1"PIPE
FOUN
D
1-
1/2"PIPE
FOUND
5/8"REBAR FOUND
5/8"REBARFOUND
(0.18' INSIDE
PROPERTY)
1"PIPE
FOUN
D
1/2"PIP
E
FOUND
1-
1/2"PIPE
FOUND
3/4"REBA
R
FOUND
1-
1/2"PIPE
FOUND
2"PIPE
FOUN
D
1-
1/2"PIPE
FOUND
5/8"REBAR FOUND
2"PIPE
FOUN
D
1-
1/2"PIPE
FOUND
1-1/2"PIPE
FOUND
(DISTURBED
)
5/8"
REBAR
FOUND
XP
XP
XP
XP
XP
XP
XP
XP
XP
89.77°'
179.48°'
90.34°'
38 39 40 41 42 43 44 45 46 47 48
2 3 4 5 6 7 8 91
10
11
12
27
28
29
30
31
32
33
34
35
36
37
16
17
18
19
20
21
22
23
24
25
26
13
14
15
N25°08'37"W
97.42'
N25°23'57"W
260.09'
N25°04'58"W
55.85'
N25°35'41"W
103.15
'
S64°40'25"W
213.77'
S65°13'04"W
100.02'
S64°34'51"W
53.45'
S58°49'47"W
84.56'S39°
56'33
"W
45.77
'
S32°
36'20
"W
47.66
'
S21°02'39"W
51.03'
S11°21'10"W
50.39'
S01°32'33"W
49.12'
S04°06'30"E
46.94'
S05°58'19
"E52.22'
S07°54'01"E
48.93'
S10°01'2
3"E
49.22'
S11°
43'45"E
48.62'
S14°01'3
8"E
48.45'
S24°35'47"E
65.46' S64°21'17"W
70.49'S64°18'54"W
123.16'
S25°21'0
7"E
159.78'
S64°25'07"W
290.71'
S64°18'54"W
19.09'
N64°32'20"E
81.66'
N64°21'53"E
63.28'N64°34'46"E
211.32'
N64°51'30"E
98.97'
N25°32'52"W
44.84'N64°19'40"E
77.55'
N25°37'56"W
44.91'
N64°36'18"E
107.27'
N26°02'33"W
68.82'
S63°41'43"W
29.79'N64°18'15"E
8.72'
RELOCATED ENTRANCE GATE ENTRANCE GATE
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C. T
HE
RE
PR
OD
UC
TIO
N, C
OP
YIN
G, O
R O
TH
ER
US
E O
F T
HIS
DR
AW
ING
WIT
HO
UT
WR
ITT
EN
CO
NS
EN
T O
F S
TU
DIO
2LR
, IN
C. IS
PR
OH
IBIT
ED
AN
D IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JEC
T T
O L
EG
AL A
CT
ION
.
STU
DIO
2LR
, IN
C.
2428 M
AIN
STR
EE
T
CO
LU
MB
IA,
SC
29201
P 8
03.2
33.6
602
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
11/2
/2016 1
0:4
5:4
3 A
M
16073
11/02/16
AS1
VIS
TA
TO
WE
RS
5000
BU
ILD
ING
RE
NO
VA
TIO
NS
SITE PLAN
HO
ME
S U
RB
AN
.
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A
REVISIONS
NO. DATE DESCRIPTION
REQUIRED PARKING COUNT
APARTMENT UNITS < 500 sqft = 0501-750 sqft - 58 x 1.75 = 102>750 sqft - 205 x 2 = 410Total 512
OFFICE/AMMENITIES2000 Building = 2,6063000 Building = 2,3495000 Building = 9,324
14,279
14,279/1000 = 14.279 x 3 = 42.837 = 43
TOTAL REQUIRED PARKING512 + 43 = 555
EXISTING PARKING COUNTS
1" = 30'-0"1
SITE PLAN
PARKING SUMMARY
TOTAL REQUIRED PARKING = 555EXISTING PARKING = 481
PAINTED EXISTING STUCCO
PERFORATED METAL JULIET BALCONY
EXISTING STOREFRONT AND CURTAIN WALL MULLIONS PAINTED
PAINTED METAL STRUCTURE
WOOD PLANK CEILING
PAINTED EXISTING STUCCO
PERFORATED METAL JULIET BALCONY
EXISTING STOREFRONT AND
CURTAIN WALL MULLIONS PAINTED
PAINTED METAL RAILING
PAINTED EXISTING STUCCO
PERFORATED METAL JULIET BALCONY
EXISTING STOREFRONT AND
CURTAIN WALL MULLIONS PAINTED
PAINTED METAL STRUCTURE
WOOD PLANK CEILING
PAINTED EXISTING STUCCO
PERFORATED METAL JULIET BALCONY
EXISTING STOREFRONT AND
CURTAIN WALL MULLIONS PAINTED
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C. T
HE
RE
PR
OD
UC
TIO
N, C
OP
YIN
G, O
R O
TH
ER
US
E O
F T
HIS
DR
AW
ING
WIT
HO
UT
WR
ITT
EN
CO
NS
EN
T O
F S
TU
DIO
2LR
, IN
C. IS
PR
OH
IBIT
ED
AN
D IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JE
CT
TO
LE
GA
L A
CT
ION
.
STU
DIO
2LR
, IN
C.
2428 M
AIN
STR
EE
T
CO
LU
MB
IA,
SC
29201
P 8
03.2
33.6
602
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
11/2
/2016 1
0:3
4:1
0 A
M
16073
11/02/16
A1
VIS
TA
TO
WE
RS
5000
BU
ILD
ING
RE
NO
VA
TIO
NS
EXTERIOR ELEVATIONS
HO
ME
S U
RB
AN
.
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A
REVISIONS
NO. DATE DESCRIPTION
1/8" = 1'-0"1
NORTH ELEVATION D/DRC
1/8" = 1'-0"2
SOUTH ELEVATION D/DRC
1/8" = 1'-0"3
EAST ELEVATION D/DRC
1/8" = 1'-0"4
WEST ELEVATION D/DRC
0' 4' 8' 16' 32'
0' 4' 8' 16' 32'
0' 4' 8' 16' 32' 0' 4' 8' 16' 32'
EXISTING SOUTH ELEVATION
EXISTING STUCCO TO BE PAINTEDEXISTING STOREFRONT AND CURTAIN WALL MULLIONS PAINTEDEXISTING GLASS TO REMAINPERFORATED METAL JULIET BALCONYPAINTED METAL STRUCTURE WITH WOOD PLANK CEILINGPAINTED METAL RAILING
PROPOSED SOUTH ELEVATION
EXISTING STUCCO TO BE PAINTEDEXISTING STOREFRONT AND CURTAIN WALL MULLIONS PAINTEDEXISTING GLASS TO REMAINPERFORATED METAL JULIET BALCONYPAINTED METAL STRUCTURE WITH WOOD PLANK CEILINGPAINTED METAL RAILING
PROPOSED SOUTH ELEVATION