THIS ADDENDUM MUST BE ACKNOWLEDGED.
THIS ADDENDUM SHALL BECOME A PART OF THIS SOLICITATION. Amend Invitation to Bid 16-RP-2450 as follows: Please see attached sign in sheet from the pre-bid meeting and additional information. The dates and times for visiting the site will be as follows: January 13th from 9-11am and January 20th from 9-11am. If your proposal has been submitted and you wish to amend it, please modify your proposal on company letterhead. The amended proposal must be received prior to or included at the time and date set for the proposal opening. Each modification submitted to the District's Purchasing Office located at 1617 S. Acoma St. Denver, CO 80223. It must have Vendor’s name and return address and the applicable RFP number and title of the RFP clearly marked on the face of the envelope. If more than one modification is submitted, the modification bearing the latest date of receipt by the District's Strategic Sourcing Office will be considered the valid modification. *****This addendum must be acknowledged, whether or not you amend your proposal.***** This Addendum must be included in your submittal or proposal, providing you do not need to amend your proposal.
PRINT OR TYPE YOUR INFORMATION
Name of Company: ____________________________________________ Fax: _____________
Address: ________________________ City/State: ________________ Zip: ______________
Contact Person: ___________________ Title: _____________________ Phone: ___________
Authorized Representative’s Signature: ____________________________ Phone: ___________
Printed Name: ____________________ Title: _____________________ Date: _____________
Approved by: ______________ Date: _____________
Reviewed by: ______________ Date: _____________
16-RP-2450 Addendum # 1
Denver Public Schools Purchasing Department
1617 S. Acoma St. Denver, Colorado 80223
INVITATION TO BID 16-RP-2450
ADDENDUM NUMBER ONE January 6, 2016
303 S Broadway #200-239, Denver, CO 80290 www.BuildSafeEnviro.com
Asbestos Inspection Report
Commercial/Office Building
5590 West Evans Avenue
Denver, Colorado 80227
Prepared for:
Denver Public Schools
Attn: Geoff Mills
1617 S Acoma Street
Denver, Colorado 80223
Prepared by:
BuildSafe Environmental, Ltd.
303 South Broadway, Suite 200-239
Denver, Colorado 80209
BuildSafe Project Number: DPS-003-1
Table of Contents
Section 1 Project Overview .................................................................................................... 1
A. Scope of Work .................................................................................................................. 1
B. Inspection Findings ........................................................................................................... 1
C. Inspection Comments ....................................................................................................... 1
Section 2 Asbestos Inspection ................................................................................................ 2
A. Suspect Asbestos Containing Building Materials ................................................................... 3
B. Sampling and Laboratory Analysis ...................................................................................... 4
Section 3 Conclusion ............................................................................................................. 5
A. Limitations ....................................................................................................................... 5
Section 4 Regulations ............................................................................................................ 7
List of Appendices
Appendix A – Suspect Asbestos Containing Building Materials Report
Appendix B – Assumed ACBM Locations
Appendix C – Functional Space Description Report
Appendix D – Drawing – Functional Space Locations
Appendix E – Laboratory Reports and Chain of Custody Documents
List of Acronyms
ACM – Asbestos Containing Material
ACBM – Asbestos Containing Building Material
BuildSafe – BuildSafe Environmental, Ltd.
CDPHE – Colorado Department of Public Health and Environment
EA – Each
EPA – Environmental Protection Agency
ft2 or SF – Square Feet
GAC - General Abatement Contractor
LF – Linear Feet
NESHAP – National Emission Standards for Hazardous Air Pollutants
OSHA – Occupational Safety and Health Administration
SFRD - Single-Family Residential Dwellings
5590 West Evans Ave – Asbestos Inspection Report April 28, 2015
DPS-003-1
BuildSafe Environmental, LTD P a g e | 1
Section 1 Project Overview
A. Scope of Work
BuildSafe Environmental, Ltd (BuildSafe) has performed a renovation-specific asbestos
inspection to include all interior and exterior spaces of the commercial/office building,
located at 5590 West Evans Avenue, Denver, Colorado (project “Site”). Denver Public
Schools (DPS) is potentially purchasing the property and requested that BuildSafe perform
an asbestos inspection of the two story building located at the Site. The inspection was
conducted by Colorado state-certified asbestos building inspectors in accordance with the
Environmental Protection Agency (EPA) Asbestos Hazard and Emergency Response Act
(AHERA) and Colorado Department of Public Health and Environment (CDPHE) Air Quality
Control Commission Regulation No. 8, Part B – Asbestos (Reg 8). The inspection activities
were performed over two field days in the Spring of 2015.
B. Inspection Findings
The following table summarizes the types and quantities of Asbestos Containing Building
Materials (ACBMs) and trace-ACBMs identified during the inspection:
No ACBMs or trace-ACBMs were identified during this inspection.
Due to the destructive nature of sampling, the following exterior and interior materials were
identified and inventoried; however, for aesthetic and waterproofing integrity they were
not sampled and are assumed to be ACBMs until they can be sampled by qualified
personnel:
• Miscellaneous Adhesive (MA01) – Unknown adhesive associated with ceramic wall
tile
• Exterior Stucco (ES01) – Tan rough stucco
• Roof Sheeting (RSH01) – Black vinyl roofing with black sealant at the seams
Suspect ACBM descriptions including sampling information, material classifications, and
laboratory analysis information are provided in the report located in Appendix A. Locations
of ACBMs/assumed ACBMs are located in Appendix B. Functional space descriptions report
is located in Appendix C. Functional space designation drawing is located in Appendix D.
C. Inspection Comments
The following items should be taken into consideration regarding ACBMs within the Site:
5590 West Evans Ave – Asbestos Inspection Report April 28, 2015
DPS-003-1
BuildSafe Environmental, LTD P a g e | 2
• A limited destructive approach was used for this inspection. Interiors of mechanical
chases, interstitial spaces in ceilings and walls, crawl spaces, mechanical tunnels, and
other areas not readily accessible without significant destruction were not inspected as
part of this project.
• Exterior spaces and materials were identified and inventoried, however, to maintain
aesthetic and waterproofing integrity these materials were not sampled. These materials
are assumed to contain asbestos until they are properly sampled by qualified personnel.
• Fire doors were identified and inventoried, however, to maintain fire proofing integrity
the fire doors were not sampled. Prior to removal or disposal, the fire doors must be
appropriately sampled by qualified personnel.
• Gasket/packing material, interior of HVAC equipment, electrical panels, etc. were not
inspected or inventoried due to live systems throughout the building. Prior to removal
or disturbance, these materials must be inspected by qualified personnel after the
systems have been taken offline, locked out and tagged out.
• Chalkboards were not inventoried or sampled as part of this inspection as they are not
building materials. Prior to disturbance, removal or disposal, all chalkboards should be
inspected and sampled as suspect ACM and handled as such.
Section 2 Asbestos Inspection
The inspection procedure was conducted in accordance with EPA Asbestos Hazard and
Emergency Response Act (AHERA), CDPHE Reg 8, and applicable Occupational Health and
Safety (OSHA) guidelines and regulations. These regulations specify requirements and
protocols for conducting asbestos inspections, sample analysis, and asbestos abatement.
The client is planning renovation activities that could potentially disturb suspect ACBMs at
the Site. CDPHE Reg 8 requires that all suspect ACBMs be properly inspected and sampled
by certified personnel prior to conducting any repair/renovation activities that will disturb
the suspect ACBMs. All samples were analyzed by a laboratory accredited under the National
Voluntary Laboratory Accreditation Program (NVLAP). The CDHPE has established the
following trigger levels for different types of properties, which specify how suspect and
confirmed ACBMs are inspected and subsequently abated:
• With regard to single-family residential dwellings (SFRD), the trigger levels are: 50 LF
on pipes, 32 SF on other surfaces, or the volume equivalent of a 55-gallon drum
• With regard to all areas other than SFRDs, the trigger levels are 260 LF on pipes, 160
SF on other surfaces, or the volume equivalent of a 55-gallon drum
5590 West Evans Ave – Asbestos Inspection Report April 28, 2015
DPS-003-1
BuildSafe Environmental, LTD P a g e | 3
The purpose of the inspection was to identify, visually inspect, and sample all suspect
ACBMs at the direction of the client that may be disturbed during the course of the
renovation work.
A. Suspect Asbestos Containing Building Materials
Homogenous Material Types
The inspection involved identification and sampling of suspect ACBMs in the areas
established by the client that would be part of the scope of work. Suspect ACMBs were
grouped into homogenous materials based on color, texture, and date of application.
Homogenous materials were given distinct codes (CDW01, FTC02, TS05, etc.) based on the
type sequence of the homogenous material. Details about the size, color, condition,
friability, quantity, location within each functional space, and other important details for
each homogenous material were reported as part of the inspection. Homogenous materials
are grouped into one of three categories based on intended use:
1. Surfacing Material – material that is sprayed on, troweled on, or otherwise applied to
surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural
members, or other materials on surfaces for acoustical, fireproofing, or other purposes.
2. Thermal System Insulation – material applied to pipes, fittings, boilers, breeching,
tanks, ducts, or other interior structural components to prevent heat loss or gain,
prevent water condensation, or for other purposes.
3. Miscellaneous Materials – interior building material on structural components,
structural members or fixtures, such as floor and ceiling tiles, and does not include
surfacing material or thermal system insulation.
Homogenous Material Friability
Each homogenous material was given one of the three following friability categories defined
by the EPA and CDPHE:
1. Friable Material – materials that can be crumbled or reduced to powder by hand
pressure.
2. Category I Non-friable Material – materials that cannot be crumbled or reduced to
powder by hand pressure including resilient floor coverings, gaskets, packing materials
and asphalt-impregnated roofing materials.
3. Category II Non-friable Materials – all other materials that cannot be crumbled or
reduced to powder by hand pressure that do not include category I non-friable
materials.
5590 West Evans Ave – Asbestos Inspection Report April 28, 2015
DPS-003-1
BuildSafe Environmental, LTD P a g e | 4
Homogenous Material Condition
Each homogenous material was given one of three condition categories based on visual
observation defined by the EPA and CDPHE:
1. Good Condition – No visible signs of damage were observed during the inspection.
2. Damaged Condition – Visible signs of damage less than ten percent spread over the
entire material or twenty five percent localized.
3. Significantly Damaged Condition – Severe damage greater than ten percent spread
over the entire material or twenty-five percent localized.
B. Sampling and Laboratory Analysis
Sample Collection
Bulk samples of each suspect homogenous material were collected randomly throughout
the homogenous material area within the scope of work. Bulk samples were sampled all of
the way through the material so that all associated layers within each homogenous material
are represented. Bulk samples were placed in closeable sample bags and then labeled with
a permanent marker with distinct sample identifiers (CDW1-1, FTC2-1, MISC2-3, etc.) for
transport to the laboratory. Sample locations and photographs of the homogenous materials
were also collected at this time during the inspection. Sample quantities of each
homogenous material were collected based on material type and quantity detailed in the
following table as required by regulation:
Homogenous Material Type Quantity Minimum Number of
Samples
Surfacing material
0 to <1,000 SF
1,000 to 5,000 SF
>5,000 SF
3
5
7
Thermal System Insulation Each Material
Patch < 6 LF, SF
3
1
Miscellaneous Material Each Material 1
Laboratory Sample Analysis
Bulk samples were submitted to the laboratory along with a completed chain of custody
form to the above listed NVLAP accredited laboratory for analysis by polarized light
microscopy (PLM) techniques per EPA methodology (EPA-600/M4-82-020, Dec. 1982).
5590 West Evans Ave – Asbestos Inspection Report April 28, 2015
DPS-003-1
BuildSafe Environmental, LTD P a g e | 5
Microscopic visual estimation was used in obtaining the percentage of asbestos within each
layer of the bulk samples. Laboratory report(s) and chain of custody document(s) can be
located in Appendix E.
Asbestos Containing Building Materials
EPA and CDPHE both define an ACBM as a material which has an asbestos content of
greater than one percent. In the event that a friable material is estimated to contain trace
asbestos (i.e., between zero and one percent), that material must undergo point count
analysis by the laboratory to confirm that the material is trace asbestos-containing;
otherwise, it must be assumed as ACBM. Further, if a point count analysis is performed on
a bulk sample, the point count result takes precedent over the visual estimation result. See
appendix A for laboratory report and chain of custody documents.
Section 3 Conclusion
BuildSafe has performed anasbestos inspection of the building located at the Site Address.
Through visual inspection and laboratory analysis of bulk samples collected at the Site
Address, BuildSafe recommends hiring a certified asbestos general abatement contractor
to remove any ACBMs that may have been identified within the scope of work. All
inspection activities were conducted at the direction of the client and only include those
materials, quantities, and locations detailed in Appendix A and C of this report. See sections
1 and 2 of this report for information regarding inspection scope of work, suspect ACBMs,
confirmed ACBMs, sample information and laboratory analysis results.
A. Limitations
General Comments and Limitations
Reasonable effort was made by BuildSafe to locate and sample accessible suspect ACBMs
within the scope of work. However, for any structure, the existence of unique or concealed
suspect ACBMs is a strong possibility. BuildSafe only inspected and collected suspect ACBM
bulk samples in the repair/renovation areas at the direction of the client. This asbestos
inspection report is not considered a comprehensive asbestos demolition inspection report
and is only valid for the materials and locations detailed in Appendix A and C of this report.
Should disturbance of suspect ACBMs expand outside of materials and locations listed in
Appendix A and C of this report those locations must be properly inspected and sampled
by qualified personnel prior to disturbance. Any subsequent abatement of ACBMs must be
performed in accordance with all federal, state, and local regulations pertaining to
abatement, transport, and disposal of ACBMs.
5590 West Evans Ave – Asbestos Inspection Report April 28, 2015
DPS-003-1
BuildSafe Environmental, LTD P a g e | 6
The asbestos inspection was conducted in a manner consistent with the level of care and
skill exercised by professionals of the asbestos inspection profession. The results, findings,
conclusions, and recommendations expressed in this report are based on conditions
observed during our limited inspection of the repair/renovation areas. The information
contained in this report is relevant to the date on which this survey was performed, and
should not be relied upon to represent conditions at a later date. This report has been
prepared on behalf of and exclusively for use by the client for specific application to the
project as discussed. Contractors or consultants reviewing this report must draw their own
conclusions regarding further investigation or remediation deemed necessary. BuildSafe
does not warrant the work of regulatory agencies, laboratories, or other third-parties
supplying information which may have been used in the preparation of this report. No
warranty, express or implied is made.
Sincerely,
Patrick Engels, Project Manager Build Safe Environmental 303 South Broadway, 200-239 Denver, Colorado 80209 720.253.3181 [email protected]
5590 West Evans Ave – Asbestos Inspection Report April 28, 2015
DPS-003-1
BuildSafe Environmental, LTD P a g e | 7
Section 4 Regulations
General Applicability of Regulations - Except to the extent that more explicit or more
stringent requirements are written directly into the Project Specification, all applicable
regulations shall be upheld during all phases of this project.
GAC Responsibility - The GAC shall assume full responsibility and liability for the compliance
with all applicable federal, state, and local regulations pertaining to hazardous waste
management and disposal.
CDPHE
• CDPHE AQCC Regulation No.8, Part B – Asbestos
• Hazardous Materials and Waste Management Division, Section 5 of 6 CCR 1007-2
EPA
• Management of Hazardous Wastes Resource Conservation and Recovery Act RCRA
Title 40, Parts 260-268 of the Code of Federal Regulations
• National Emissions Standard for Hazardous Air Pollutants, 40 CFR Part 61 and 63
• Asbestos Hazard Emergency Response Act, 40 CFR 763
DOT
• Hazardous Substances
Title 49, Part 171 and 172 of the Code of Federal Regulations
• Hazardous Material Regulations
General Awareness and Training Requirements for Handlers, Loaders and Drivers
Title 49, Parts 171-180 of the Code of Federal Regulations
OSHA
• General Construction Standard, 29 CFR 1926.1101
• Toxic and Hazardous Substances – Asbestos, 29 CFR 1910.1001
• Personal Protective Equipment – Respirators, 29 CFR 1910.134
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: BBA01
Result: Non ACBM
Description: Light tan caulk gun applied, soft pliable Baseboard Adhesive, associated with vinyl cove base -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-ST01-BBA01-01
ST01w wall, 1' f n, at floor Black cove base NDPLM 95 %
Off white mastic NDPLM 5 %
5590-1-230-BBA01-02 230n wall, at e wall, at floor Black cove base NDPLM 90 %
Off white mastic NDPLM 10 %
5590-1-15-BBA01-03 15w wall, 2' f s, at floor Black cove base NDPLM 92 %
Off white mastic NDPLM 8 %
Material ID: CA01
Result: Non ACBM
Description: Yellow soft, pliable, semi-sticky Carpet Adhesive, associated with carpet -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-ST01-CA01-01 ST01floor, 2' f s, 4' f e Yellow mastic NDPLM 100 %
5590-1-209-CA01-02 209floor, 12' f n, 2' f e Yellow mastic NDPLM 100 %
5590-1-17-CA01-03 17floor, 1' f s, 1' f e Yellow mastic NDPLM 100 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: CA02
Result: Non ACBM
Description: Brown soft, pliable Carpet Adhesive -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-30-CA02-01 30floor, 3' f s, 12' f e Tan resinous material NDPLM 100 %
Material ID: CA03
Result: Non ACBM
Description: Tan dry, brittle, thinly applied Carpet Adhesive -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-34-CA03-01 34floor, 7' f s, 4' f e Tan resinous material NDPLM 100 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: CDW01
Result: Non ACBM
Description: 1/2" white soft, fibrous Composite Drywall, Tape & Jt. cmpd, associated with gray paper backing -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-01-CDW01-01 01w wall, at n wall, 10' up Pink/tan drywall NDPLM 85 %
White compound with white paint
NDPLM 15 %
5590-1-211-CDW01-02
211s wall, at w wall, 8' up Pink/tan drywall NDPLM 70 %
White compound with tan paint
NDPLM 10 %
White joint compound NDPLM 10 %
White tape NDPLM 10 %
5590-1-18-CDW01-03 18w wall, at s wall, 8' up White compound NDPLM 15 %
White/tan drywall NDPLM 85 %
5590-1-28-CDW01-04 28e wall, at s wall, 8' up White compound NDPLM 15 %
White/tan drywall NDPLM 85 %
5590-1-206-CDW01-05
206s wall, 6' f w, 8' up White compound with tan
paintNDPLM 20 %
White/tan drywall NDPLM 80 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: CDW02
Result: Non ACBM
Description: 5/8" gray fibrous, chalky, soft Composite Drywall, Tape & Jt. cmpd, associated with dark gray paper backing -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-14-CDW02-01 14s wall, 5' f w, 11' up Tan drywall NDPLM 85 %
White compound NDPLM 15 %
5590-1-17-CDW02-02 17s wall, 2' f w, 9' up Tan drywall NDPLM 80 %
White compound NDPLM 10 %
White joint compound NDPLM 5 %
White tape NDPLM 5 %
Material ID: CMS01
Result: Non ACBM
Description: White chalky CMU Sealant, associated with CMU block 8"x16" -
Type of Material: Surfacing Material
Friable/Non Friable: Friable
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-ST01-CMS01-01
ST01e wall, 7' f n, 6' up Gray cinder block NDPLM 60 %
White block filler with white/mulit-colored paint
NDPLM 40 %
5590-1-ST203-CMS01-02
ST203s wall, 6' f e, 2' up Gray cinder block NDPLM 65 %
White block filler with white/multi-colored paint
NDPLM 35 %
5590-1-ST03-CMS01-03
ST03e wall, 2' f n, 8' up Gray cinder block NDPLM 70 %
White block filler with white/multi-colored paint
NDPLM 30 %
5590-1-ST201-CMS01-04
ST201s wall, 2' f w, 5' up Gray cinder block NDPLM 75 %
White block filler with white/multi-colored paint
NDPLM 25 %
5590-1-ST01-CMS01-05
ST01w wall, 4' f s, 8' up Gray cinder block NDPLM 60 %
White block filler with white/multi-colored paint
NDPLM 40 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: DS01
Result: Non ACBM
Description: Gray hard, brush applied Duct Sealant, associated with HVAC ducting -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-01-DS01-01 01duct, 2' f s, 1' f w, 11' up Gray sealant NDPLM 100 %
5590-1-228-DS01-02 228duct, 2' f n, 5' f e, 9' up Gray sealant NDPLM 100 %
Material ID: DS02
Result: Non ACBM
Description: White soft, gummy Duct Sealant, associated with HVAC ducting joints -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-08-DS02-01 08duct, 4' f s, 7' f e White sealant NDPLM 100 %
5590-1-217-DS02-02 217duct, 4' f s, 1' f e, 8' up White sealant NDPLM 100 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: ES01
Result: ACBM
Description: Tan/gray spongy Stucco, Exterior, associated with exterior walls -
Type of Material: Miscellaneous Material
Friable/Non Friable: Friable
Material ID: FLC01
Result: Non ACBM
Description: White soft, chalky Floor Leveling Compound -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category I
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-07-FLC01-01 07floor, 1' f s, 2' f e White plaster NDPLM 80 %
Yellow mastic NDPLM 20 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: FSM01
Result: Non ACBM
Description: Dark red tough, pliable Fire Stop Material, associated with wall penetrations -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-H03-FSM01-01 H03w wall, 1' f n, 9' up Red fibrous material NDPLM 70 %
Red resinous material NDPLM 30 %
Material ID: FTC01
Result: Non ACBM
Description: 12"x12" tan white mottle Floor Tile & Assoc. Mastic, associated with black mastic -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category I
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-22-FTC01-01 22floor, 1' f n, 7' f e Black mastic NDPLM 10 %
Pink floor tile NDPLM 90 %
5590-1-221-FTC01-02 221floor, 1' f n, 8' f w Black mastic NDPLM 5 %
Pink floor tile NDPLM 95 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: FTC02
Result: Non ACBM
Description: 12"x12" pinkish tan white mottle Floor Tile & Assoc. Mastic, associated with yellow adhesive, gray floor leveler -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category I
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-214-FTC02-01 214floor, 8' f n, 1' f e Gray compound NDPLM 3 %
Pink tile NDPLM 94 %
Tan mastic NDPLM 3 %
5590-1-227-FTC02-02 227floor, at n wall, 1' f e Pink tile NDPLM 97 %
Tan mastic with gray leveling compound
NDPLM 3 %
Material ID: FTC03
Result: Non ACBM
Description: 12"x12" green mottle Floor Tile & Assoc. Mastic -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category I
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-222-FTC03-01 222floor, 1' f s, 8' f w Gray granular cementitous
materialNDPLM 10 %
Green tile NDPLM 88 %
Tan mastic NDPLM 2 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: LIP01
Result: Non ACBM
Description: 2'x2' white/gray short random fissures and pinholes Lay-in Ceiling Panel, associated with drop ceiling -
Type of Material: Miscellaneous Material
Friable/Non Friable: Friable
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-01-LIP01-01 01ceiling, 5' f s, at w wall Gray/white ceiling tile NDPLM 100 %
5590-1-34-LIP01-02 34ceiling, 6' f, n, 4' f w Gray/white ceiling tile NDPLM 100 %
5590-1-20-LIP01-03 20ceiling, at n side, 22' f w Gray/white ceiling tile NDPLM 100 %
Material ID: LIP02
Result: Non ACBM
Description: 2'x4' white/gray short random fissures with pinholes Lay-in Ceiling Panel, associated with drop ceiling -
Type of Material: Miscellaneous Material
Friable/Non Friable: Friable
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-11-LIP02-01 11ceilinhg, 6' f n, 4' f e Gray/white ceiling tile NDPLM 100 %
5590-1-214-LIP02-02 214ceiling, 15' f n, 6' f w Gray/white ceiling tile NDPLM 100 %
5590-1-240-LIP02-03 240ceiling, 2' f n, 5' f w Gray/white ceiling tile NDPLM 100 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: LIP03
Result: Non ACBM
Description: 2'x4' white/gray short axis fissures and pinholes Lay-in Ceiling Panel, associated with drop ceiling -
Type of Material: Miscellaneous Material
Friable/Non Friable: Friable
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-24-LIP03-01 24ceiling, 4' f n, 4' f w Gray/white ceiling tile NDPLM 100 %
Material ID: LIP04
Result: Non ACBM
Description: 2'x2' white/gray rough texture Lay-in Ceiling Panel, associated with drop ceiling system -
Type of Material: Miscellaneous Material
Friable/Non Friable: Friable
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-30-LIP04-01 30ceiling, 6' f s, 10' f e White ceiling tile NDPLM 100 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: LIP05
Result: Non ACBM
Description: 2'x4' white/gray craters and pinholes Lay-in Ceiling Panel, associated with drop ceiling -
Type of Material: Miscellaneous Material
Friable/Non Friable: Friable
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-222-LIP05-01 222ceiling, 2' f n, 6' f w Gray/white ceiling tile NDPLM 100 %
Material ID: MA01
Result: ACBM
Description: Unknown Adhesive/Mastic, Misc. -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: MA02
Result: Non ACBM
Description: Tan soft, sticky, pliable Adhesive/Mastic, Misc., associated with wall panels in vault -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-30-MA02-01 30w wall, 3' f n, 5' up Tan mastic NDPLM 50 %
Yellow resinous material NDPLM 50 %
Material ID: PS01
Result: Non ACBM
Description: White brush applied, soft Pipe Insulation Sealant, associated with fiberglass insulated pipes -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-24-PS01-01 24pipe, 6' f n, 6' f w, 11' up Silver tan wrap with white
resinous materialNDPLM 40 %
Yellow fibrous material NDPLM 60 %
5590-1-27-PS01-02 27pipe, 1' f s, 3' f e, 7' up Silver/tan wrap with white
resinous materialNDPLM 60 %
Yellow fibrous material NDPLM 40 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: RSH01
Result: ACBM
Description: Black rubber with tar sealant Roof Sheeting -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category I
Material ID: SVF01
Result: Non ACBM
Description: White blue, red specks Sheet Vinyl Flooring, associated with gray paper backing -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-ST01-SVF01-01
ST01floor, 8' f s, 5' f w Gray/blue sheet vinyl with
grya fibrous backing material
NDPLM 98 %
Tan mastic with gray debris NDPLM 2 %
5590-1-27-SVF01-02 27floor, 1' f s, 2' f e Gray/blue sheet vinyl with
gray fibrous backing material
NDPLM 95 %
Tan mastic with gray debris NDPLM 5 %
Homogenous Materials, Sample Locations and Analytical Results
5590-1
Material ID: UC01
Result: Non ACBM
Description: Black spray applied, rough Undercoatings (sink/drain pan), associated with ss sink -
Type of Material: Miscellaneous Material
Friable/Non Friable: Non-friable Category II
Sample ID Room # Sample Locations Method Phys. DescriptionAsbestos
Content
% of
Sample
Laboratory Results
5590-1-214-UC01-01 214beneath sink Black resinous material NDPLM 100 %
Locations of Asbestos Containing Materials
5590-1
1XE1 East ExteriorRoom:
Homogenous Material Quantity ConditionPotential for Disturbance NotesLocation
1,500 LowSF Good E. wall, Tan/gray spongy Stucco,
Exterior, associated with exterior walls -
ES01
1XN1 North ExteriorRoom:
Homogenous Material Quantity ConditionPotential for Disturbance NotesLocation
2,300 LowSF Good N. wall, Tan/gray spongy Stucco,
Exterior, associated with exterior walls -
ES01
1XS1 South ExteriorRoom:
Homogenous Material Quantity ConditionPotential for Disturbance NotesLocation
2,250 LowSF Good S. wall, Tan/gray spongy Stucco,
Exterior, associated with exterior
walls -
ES01
1XW1 West ExteriorRoom:
Homogenous Material Quantity ConditionPotential for Disturbance NotesLocation
150 LowSF Good W. wall, Tan/gray spongy Stucco,
Exterior, associated with exterior
walls -
ES01
23 Women's RestroomRoom:
Homogenous Material Quantity ConditionPotential for Disturbance NotesLocation
156 LowSF Good S. wall, Unknown Adhesive/Mastic,
Misc. -
MA01
238 Men's RestroomRoom:
Homogenous Material Quantity ConditionPotential for
Disturbance NotesLocation
100 LowSF Good N. wall, E. wall, Unknown Adhesive/Mastic,
Misc. -
MA01
239 Women's RestroomRoom:
Homogenous Material Quantity ConditionPotential for
Disturbance NotesLocation
290 LowSF Good N. wall, E. wall, Unknown Adhesive/Mastic, Misc. -
MA01
24 Men's restroomRoom:
Homogenous Material Quantity ConditionPotential for
Disturbance NotesLocation
540 LowSF Good N. wall, E. wall, W. wall,
Unknown Adhesive/Mastic, Misc. -
MA01
Locations of Asbestos Containing Materials
5590-1
RF200 RoofRoom:
Homogenous Material Quantity ConditionPotential for
Disturbance NotesLocation
12,000 LowSF GoodFloor, Black rubber with tar sealant Roof Sheeting -
RSH01
Functional Space List
Room ID Insp. Status Room Description North Length East Length Height
5590-1
South Length East Length
01 Inspected Entry 9 9 12 12 12
02 Inspected Office 15 15 11 11 12
03 Inspected Office 15 15 19 19 12
04 Inspected Office 15 15 10 10 12
05 Inspected Office 26 26 16 16 12
06 Inspected Office 10 10 16 16 12
07 Inspected Conference 17 17 12 12 12
08 Inspected Office 11 11 12 12 12
09 Inspected Office 10 10 12 12 12
10 Inspected Storage 14 14 12 12 12
11 Inspected Electrical 9 9 11 11 12
12 Inspected Storage 13 13 14 14 12
13 Inspected N Lobby 121 121 22 22 12
14 Inspected Office 16 16 12 12 14
15 Inspected Office 13 13 12 12 14
16 Inspected Office 13 13 12 12 14
17 Inspected Office 10 10 12 12 14
18 Inspected Office 10 10 12 12 14
19 Inspected Office 12 12 15 15 14
1XE1 Inspected East Exterior 75 0 0 0 30
1XN1 Inspected North Exterior 160 0 0 0 30
1XS1 Inspected South Exterior 0 160 0 0 30
1XW1 Inspected West Exterior 0 0 0 75 30
20 Inspected Main Lobby and Teller Area 55 55 27 27 12
Room ID Insp. Status Room Description North Length East Length Height
5590-1
South Length East Length
201 Inspected Office 19 19 19 19 10
202 Inspected Office 20 20 12 12 10
203 Inspected Office 12 12 12 12 10
204 Inspected Office 12 12 12 12 10
205 Inspected Office 11 11 12 12 10
206 Inspected Office 14 14 12 12 10
207 Inspected Storage 6 6 12 12 10
208 Inspected Office 21 21 12 12 10
209 Inspected Hallway 15 15 34 34 12
21 Inspected Main Entry Vestibule 12 12 14 14 12
210 Inspected Office 14 14 20 20 12
211 Inspected Office 17 17 20 20 12
212 Inspected Hallway 64 64 6 6 12
213 Inspected Conference Room 60 60 29 29 10
214 Inspected Break Room, Kitchen 23 23 29 29 10
215 Inspected Electrical Closet 4 4 6 6 10
216 Inspected Office 12 12 11 11 10
217 Inspected Storage 7 7 10 10 10
218 Inspected Office 19 19 14 14 10
219 Inspected Hallway 107 107 5 5 10
22 Inspected ATM Room 12 12 8 8 14
220 Inspected Storage 12 12 6 6 12
221 Inspected Storage 14 14 7 7 10
222 Inspected Server 14 14 16 16 10
223 Inspected Server 9 9 18 18 10
224 Inspected Office 10 10 10 10 10
Room ID Insp. Status Room Description North Length East Length Height
5590-1
South Length East Length
225 Inspected Office 13 13 14 14 10
226 Inspected Hallway 57 57 5 5 10
227 Inspected Break Room Vestibule 7 7 5 5 10
228 Inspected Office 12 12 11 11 10
229 Inspected Office 12 12 11 11 10
23 Inspected Women's Restroom 13 13 16 16 12
230 Inspected Office 12 12 11 11 10
231 Inspected Office 14 14 18 18 10
232 Inspected Office 15 15 12 12 10
233 Inspected Hallway 4 4 38 38 10
234 Inspected Office 13 13 24 24 10
235 Inspected Office 19 19 16 16 10
236 Inspected Janitor 8 8 6 6 10
237 Inspected Closet 12 12 4 4 10
238 Inspected Men's Restroom 11 11 14 14 10
239 Inspected Women's Restroom 12 12 17 17 10
24 Inspected Men's Restroom 13 13 16 16 12
240 Inspected Restroom vestibule 11 11 8 8 10
25 Inspected Storage 11 11 12 12 12
26 Inspected Storage 13 13 9 9 12
27 Inspected Janitor 5 5 5 5 12
28 Inspected Office 12 12 12 12 12
29 Inspected Closet 12 12 6 6 12
30 Inspected Vault 20 20 15 15 10
31 Inspected Vault storage 6 6 7 7 10
32 Inspected Closet 8 8 6 6 12
Room ID Insp. Status Room Description North Length East Length Height
5590-1
South Length East Length
33 Inspected Drive up teller 12 12 16 16 12
34 Inspected Storage 11 11 16 16 12
EL01 Inspected Elevator car 5 5 7 7 8
H01 Inspected Hallway 11 11 6 6 12
H02 Inspected Hallway 6 6 31 31 12
H03 Inspected Hallway 33 33 6 6 12
RF200 Inspected Roof 160 160 75 75 0
ST01 Inspected Stairway 10 10 20 20 13
ST02 Inspected Stairs 8 8 13 13 8
ST03 Inspected Stairs 18 18 8 8 8
ST201 Inspected Stairs 10 10 20 20 10
ST202 Inspected Stairs 12 12 23 23 10
ST203 Inspected Stairs 18 18 8 8 10
18EL01
01
02
03
04
0506
07
0809101112
13
14151617
19
20
21
22
ST02
23
24
27
28
29
30
3132
33 34
25
26
ST01
H02
H01H03
ST03
1XN1
1XE1
1XS1
1XW1
201 202 203 204 205 206
207
208209
212
210 211
213214
215
217218
237
227
240
238
239
ST203
222
221
223
226
216230228229
231
ST202
224
233
234
225
232 235
219
ST202
241
220
236
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Subcontract Number: NA
Laboratory Report: RES 317301-1
Project # / P.O. # DPS-003-1
Project Description: 5900 W. Evans Ave., Denver CO
RES 317301-1
Sincerely,
April 15, 2015
Dear Customer,
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0
for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American
Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast
Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs
respectively.
Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The
analysis has been completed in general accordance with the appropriate methodology as stated in the attached
analysis table. The results have been submitted to your office.
Build Safe Environmental
303 S. Broadway #200-239
Denver CO 80209
Blake Weise
is the job number assigned to this study. This report is considered highly confidential
and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with
personnel other than those of the client. The results described in this report only apply to the samples analyzed.
This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the
U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs
Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any
questions about this report, please feel free to call 303-964-1986.
Jeanne Spencer
President
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Page 1 of 1
1-866-RESI-ENV
www.reilab.com
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 5A Off white mastic EM 13846665590-1-ST01-BBA01-01 0 100
ND 95B Black cove base 0 100
ND 10A Off white mastic EM 13846675590-1-230-BBA01-02 0 100
ND 90B Black cove base 0 100
ND 8A Off white mastic EM 13846685590-1-15-BBA01-03 0 100
ND 92B Black cove base 0 100
ND 100A Yellow mastic EM 13846695590-1-ST01-CA01-01 0 100
ND 100A Yellow mastic EM 13846705590-1-209-CA01-02 0 100
ND 100A Yellow mastic EM 13846715590-1-17-CA01-03 0 100
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 1 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 15A White compound w/ tan paint EM 13846725590-1-01-CDW01-01 0 100
ND 85B Pink/tan drywall 20 80
ND 10A White compound w/ tan paint EM 13846735590-1-211-CDW01-02 0 100
ND 10B White tape 98 2
ND 10C White joint compound 0 100
ND 70D Pink/tan drywall 20 80
ND 15A White compound EM 13846745590-1-18-CDW01-03 0 100
ND 85B White/tan drywall 25 75
ND 15A White compound EM 13846755590-1-28-CDW01-04 0 100
ND 85B White/tan drywall 20 80
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 2 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 20A White compound w/ tan paint EM 13846765590-1-206-CDW01-05 0 100
ND 80B White/tan drywall 20 80
ND 15A White compound EM 13846775590-1-14-CDW02-01 0 100
ND 85B Tan drywall 20 80
ND 5A White joint compound EM 13846785590-1-17-CDW02-02 0 100
ND 5B White tape 98 2
ND 10C White compound 0 100
ND 80D Tan drywall 20 80
ND 40A White block filler w/ white/multi-colored paint EM 13846795590-1-ST01-CMS01-01 0 100
ND 60B Gray cinder block 0 100
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 3 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 35A White block filler w/ white/multi-colored paint EM 13846805590-1-ST203-CMS01-02 0 100
ND 65B Gray cinder block 0 100
ND 30A White block filler w/ white/multi-colored paint EM 13846815590-1-ST03-CMS01-03 0 100
ND 70B Gray cinder block 0 100
ND 25A White block filler w/ white/multi-colored paint EM 13846825590-1-ST201-CMS01-04 0 100
ND 75B Gray cinder block 0 100
ND 40A White block filler w/ white/multi-colored paint EM 13846835590-1-ST01-CMS01-05 0 100
ND 60B Gray cinder block 0 100
ND 100A Gray sealant EM 13846845590-1-01-DS01-01 0 100
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 4 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 100A Gray sealant EM 13846855590-1-228-DS01-02 0 100
ND 100A White sealant EM 13846865590-1-08-DS02-01 0 100
ND 100A White sealant EM 13846875590-1-217-DS02-02 0 100
ND 20A Yellow mastic EM 13846885590-1-07-FLC01-01 0 100
ND 80B White plaster 0 100
ND 30A Red resinous material EM 13846895590-1-H03-FSM01-01 0 100
ND 70B Red fibrous material 15 85
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 5 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 10A Black mastic EM 13846905590-1-22-FTC01-01 0 100
ND 90B Pink floor tile 0 100
ND 5A Black mastic EM 13846915590-1-221-FTC01-02 0 100
ND 95B Pink floor tile 0 100
ND 3A Tan mastic EM 13846925590-1-214-FTC02-01 0 100
ND 3B Gray compound 0 100
ND 94C Pink tile 0 100
ND 3A Tan mastic w/ gray leveling compound EM 13846935590-1-227-FTC02-02 0 100
ND 97B Pink tile 0 100
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 6 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 2A Tan mastic EM 13846945590-1-222-FTC03-01 0 100
ND 10B Gray granular cementitious material 0 100
ND 88C Green tile 0 100
ND 100A Gray/white ceiling tile EM 13846955590-1-01-LIP01-01 60 40
ND 100A Gray/white ceiling tile EM 13846965590-1-34-LIP01-02 60 40
ND 100A Gray/white ceiling tile EM 13846975590-1-20-LIP01-03 60 40
ND 100A Gray/white ceiling tile EM 13846985590-1-11-LIP02-01 60 40
ND 100A Gray/white ceiling tile EM 13846995590-1-214-LIP02-02 60 40
ND 100A Gray/white ceiling tile EM 13847005590-1-240-LIP02-03 60 40
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 7 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 100A Gray/white ceiling tile EM 13847015590-1-24-LIP03-01 60 40
ND 100A White ceiling tile EM 13847025590-1-30-LIP04-01 70 30
ND 100A Gray/white ceiling tile EM 13847035590-1-222-LIP05-01 60 40
ND 50A Yellow resinous material EM 13847045590-1-30-MA02-01 0 100
ND 50B Tan mastic 0 100
ND 40A Silver tan wrap w/ white resinous material EM 13847055590-1-24-PS01-01 4 96
ND 60B Yellow fibrous material 90 10
ND 40A Yellow fibrous material EM 13847065590-1-27-PS01-02 90 10
ND 60B Silver/tan wrap w/ white resinous material 40 60
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 8 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 2A Tan mastic w/ gray debris EM 13847075590-1-ST01-SVF01-01 0 100
ND 98B Gray/blue sheet vinyl w/ gray fibrous backing material 20 80
ND 5A Tan mastic w/ gray debris EM 13847085590-1-27-SVF01-02 0 100
ND 95B Gray/blue sheet vinyl w/ gray fibrous backing material 20 80
ND 100A Black resinous material EM 13847095590-1-214-UC01-01 0 100
ND 100A Tan resinous material EM 13847195590-1-30-CA02-01 (Not 0 100
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 9 of 10
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 317301-1
Build Safe Environmental
DPS-003-1
5900 W. Evans Ave., Denver CO
April 13, 2015
24 Hour
April 15, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual
Effective January 1, 2015Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID NumberLAYER
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
PhysicalDescription
SubPart(%)
Visual
Estimate (%)
ND=None DetectedTR=Trace, <1% Visual EstimateTrem-Act=Tremolite-Actinolite
NonAsbestosFibrous
Components(%)
Non-Fibrous
Components(%)
Asbestos Content
ND 100A Tan resinous material EM 13847205590-1-34-CA03-01 (Not 0 100
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986F: 303-477-4275
1-866-RESI-ENVwww.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 10 of 10