Upload
pradeep-dhiman
View
215
Download
0
Embed Size (px)
Citation preview
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
1/10
PM CHECK LIST.
.
2. Carry out the power measurements through OMT Tool Answer Comment
Customer Name AIRTEL
Circle Name : DEL
.
Zone : Del_DT
.
Site ID : 1841
.
2. Carry out the power measurements through OMT Tool Answer Comment
Town SC
Date of PM : 03-09-2015 02:20:17 PM
.
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
2/10
GPS Lat Long :Location Lat / Long : 28.480835000000003 / 77.33496833333334
.
2. Carry out the power measurements through OMT Tool Answer CommentSite Type: ( Critical >10/ Major , 1/ Minor=1) MINOR
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
3/10
Note: 1. Check all the feeder cables, Radio cables for any physical
damage.
.
2. Carry out the power measurements through OMT Tool
.
No of sites dependent : 1
.
BSC Name : 15
.
Cabinet Type (Select no. of cabinet type) : 6
.
2. Carry out the power measurements through OMT Tool Answer Comment
Choose BTS - 1
BTS1
CABINET
TYPE (2G)
Cabinet Type - 2 2964
Choose BTS - 3
BTS1
CABINET
TYPE (2G)
Cabinet Type - 4 6601
Choose BTS - 5
BTS1
CABINET
TYPE (3G)
Cabinet Type - 6 6601
BTS (Select no. of BTS) : 13
.
2. Carry out the power measurements through OMT Tool Answer Comment
BTS - 1 1
Choose Cell - 2 CELL A
VSWR Settings (as per standard value should be Class 1=1.8,
Class 2 = 1.5 ) - 3
CLASS
1=1.8
&CLASS 2 =
1.58
ASM Settings( Time 1440, Samples 7000 ) - ON -Screen print shot
to be attached ( Antenna 1 ) - 4
TIME 1440,
SAMPLES
7000
ASM Settings( Time 1440, Samples 7000 ) - ON -Screen print shot
to be attached ( Antenna 2 ) - 5
TIME 1440,
SAMPLES
7000
ASM Setting for alarm supervision ( Class 2 -5 dBm & Class 1 -8
dBm) - 6
CLASS 2 -5
DBM
&CLASS 1 -8
DBM
VSWR Values ( DX1 ) - 7 : 1.26
.
VSWR Values ( DX2 ) - 8 : 1.25
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
4/10
.
VSWR Values ( TX1 ) - 9 : 1.24
.
2. Carry out the power measurements through OMT Tool Answer Comment
3G Antenna Threshold Value (50 / Not OK ) - 10 50
Colocated 3G BTS - VSWR ( DX1 ) - 11 : 1.12
.
Colocated 3G BTS - VSWR ( DX2 ) - 12 : 1.15
.
Colocated 3G BTS - VSWR ( TX1 ) - 13 : 1.24
.
2. Carry out the power measurements through OMT Tool Answer Comment
DOOR OPEN OK
MAINS FAIL OK
DG ON OK
DG FAILS TO START NA
DG FAILS TO STOP NA
DG FUEL LEVEL LOW NA
RECTIFER FAIL OK
SITE ON BATTERY OK
BATTERY FUSE FAIL NA
LOAD FUSE FAIL NA
HIGH TEMP OK
FIRE & SMOKE OK
LOW BATTERY VOLTAGE OK
AC-1 FAULTY NA
BOTH AC FAULTY NA
DG FAULTY OK
Link (Select no. of link) : 17
.
Far End Site ID - 1 : 5871.
2. Carry out the power measurements through OMT Tool Answer Comment
Type of Link PDH/SDH - (TN / MLE / Hicap ) - 2 MLTN
NMS Visibility Status - 3 YES
Alarms on TXMN Eqpt. - 4 : no
.
Rcv Level [ Actual ] (RX1 / RX2 ) - 5 : 41.6/41.3
.
Rcv Level [PLANNED] - 6 : 42.5
.
Tx Power Planned - 7 : 2
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
5/10
.
Tx Power Actual - 8 : 2
.
Radio Index ( Type of Radio ) - 9 : 23
.
2. Carry out the power measurements through OMT Tool Answer Comment
Link capacity (4E1/8E1/16E1/32E1/63E1/75E1) (1+1/1+0) - 10 4E1lINK rEMARKS (1+1/1+0) - 11 1+1
Link Type (Ring/ Star/ Linear) - 12 RING
MW Antenna Size ( Planned/ Installed ) - 13 : . 6
.
MW Antenna Height ( Plan v/s Actual ) - 14 : 25m
.
Tx Frequency ( Planned ) - 15 : 20322
.
Tx Frequency ( Actual ) - 16 : 22022/23170
.
2. Carry out the power measurements through OMT Tool Answer Comment
ODU Earthing - 17 OK
2. Carry out the power measurements through OMT Tool Answer Comment
Weather proofing tap quality
MW / IF Connectors weather proofing at all MW ODUs [ OK / NOTOK ]
All Feeder cable & Jumper connectors weather proofing at GSM
antenna interface & feeder-Jumper interface. [ OK / NOT OK ]
Weather proofing of IF cable grounding point & feeder cable
grounding points. [ OK / NOT OK ]
Earthing of all MW ODUs
Check Antennae Mountings and Fixtures ( GSM & MW) tightening
& installation as per guidelines.
Tightning of all MW antenna & GSM antenna & installation as per
guidelinesMW Coupler/Strut rods fixing for 1.2,1.8 Mtr MW Antenna as per
installation guidelines ( 90 degree +- 15 degree )
GSM antenna orientation & tilt as per the design :
.
2. Carry out the power measurements through OMT Tool Answer Comment
RF/ IF cable is free from damages.
If site is monkey impacted then protection of weather proofing by
any type of covering & protection of IF cable by condute pipe. (OK/ NOT OK/ NA)
Whether GSM/Microwave Antenna being obstructed by third party
installations/Buildings [ YES/ NO ]
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
6/10
Routing of IF/ Feeder/ OFC cables(Tied with Tie /Clamp) & entry to
roxtek. In Snake shape
Is there any rusting of EGB/IGB/strips?
Is EGB/IGB is connected to earthing Pits
Earth Resistance Value :
.2. Carry out the power measurements through OMT Tool Answer Comment
Labeling on Mw antennas/ RAUs for far end ID & feeder cables for
cell identification.
There is no extra antenna/ radio/ material on the tower which is not
in use.
TMA installed on site :
.
TMA working on site :
.
TMA lying on site :
.
2. Carry out the power measurements through OMT Tool Answer Comment
Metallic cable tie for outdoor & plastic tie for indoor is used.
EMF Danger Signage Boards Present on site
EMF Caution Signage Boards Present on site
EMF Warning Signage Boards Present on site
Roxtek Sealing & any other sepagae sealing. ( OK/ NOT OK) OK
Transmission Eqpts supply on critical LVD OK
Grouting of MW & BTS rack is proper. OK
Grounding of telecom equipments. OK
a)-MW rack OK
b) MW Magzines OK
c) BTS Eqpt. OK
d) IGB to EGB & Earth pit connectivity OK
e) Fan Units OK
All cables routing ( Jumpers, Feeder, PCM/E1, alarm, power ), dcpower cable ( OK/ Not OK)
OK
All cables labelling ( Jumpers, Feeder, PCM/E1, alarm, power ),
IDUs for far end, dc power cable in SMPS ( OK/ Not OK)OK
All the PCM/E1 / Patch cord cables in Transmission rack are
routed properly.OK
BTS door fitted properly & door filter is clean. OK
BTS & Tx cabinet is cleaned. OK
Dummy plates are present in all empty slots - BTS OK
Dummy plates are present in all empty slots - Tx equipments (
AXX/ TN) OK
All Fan units installed & working for Hi CAP/ MLE above the AMM ,
TN & BTS.OK
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
7/10
Is there any extra material kept on site OK
1+1 power card availability of Tx equipments ( AXX/ TN etc) OK
Infra issues observations- ( AC Faulty/ Less than required
capacity/ High Temp/ Door Open/ Missing earthings, Battery cell
leakage Any other issue etc)
OK
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
8/10
Take photo of O/D :
.
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
9/10
Take photo of I/D :
.
7/23/2019 Del_ Del_south Faridabad_pm Check List_2015!09!03 14-28-30.0
10/10
Take photo of Issue :
.
Issue details : door open
.