DB1 DB1
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type 2
Material/Finish:Malleable Iron/Zinc Plated
Optional Finish:Mechanically GalvanizedContact your local representative for pricing and availability.
Third Party Certification:UL Listed: E-11853
CSA Certified: 009795
Applicable Third Party Standards:UL Standard: 514BCSA Standard: C22.2 No. 18Fed. Spec: W-F-408ENEMA: FB-1
Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Height
1⁄2 2-50 11⁄32 3⁄8 3⁄4 2-75 11⁄4 7⁄16
1 2-100 19⁄16 1⁄2
11⁄4 2-125 2 5⁄8 11⁄2 2-150 25⁄32 5⁄8 2 2-200 25⁄8 5⁄8 21⁄2 2-250 33⁄16 3⁄4
3 2-300 313⁄16 15⁄16
31⁄2 2-350 47⁄16 15⁄16
4 2-400 415⁄16 11⁄16
5 2-500 6 13⁄16
6 2-600 73⁄8 15⁄16
Type 3Capped Bushings
Features:Bushings are supplied with plastic insert cap.
Material/Finish:Malleable Iron/Zinc Plated
Optional Finish:Mechanically GalvanizedContact your local representative for pricing and availability.
Third Party Certification:UL Listed: E-11853
CSA Certified: 009795
Applicable Third Party Standards:UL Standard: 514BCSA Standard: C22.2 No. 18Fed. Spec: W-F-408ENEMA: FB-1
Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Height
1⁄2 3-50 11⁄32 3⁄8 3⁄4 3-75 11⁄4 7⁄16
1 3-100 19⁄16 1⁄2 11⁄4 3-125 2 5⁄8
11⁄2 3-150 25⁄32 5⁄8 2 3-200 25⁄8 5⁄8 21⁄2 3-250 33⁄16 3⁄4 3 3-300 313⁄16 15⁄16
31⁄2 3-350 47⁄16 15⁄16
4 3-400 415⁄16 11⁄16
5 3-500 6 13⁄16
6 3-600 73⁄8 15⁄16
*U.L. Listing not applicable
Type 2
Malleable Iron Conduit BushingsThreaded (NPS) For Rigid Conduit & IMC
Type 3
DB2 DB2
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type IB
Feature:• Temperature rating 105°C
Material:Polypropylene (gray)
Third Party Certification:UL Listed: E-11853
CSA Certified: 057250
Applicable Third Party Standards:UL Standard: 514BCSA Standard: C22.2 No. 18Fed. Spec: W-F-408E
Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Max. Height
1⁄2 IB-50 11⁄16 3⁄8 3⁄4 IB-75 15⁄16 7⁄16
1 IB-100 19⁄16 9⁄16
11⁄4 IB-125 2 9⁄16
11⁄2 IB-150 21⁄4 9⁄16
2 IB-200 27⁄8 5⁄8
21⁄2 IB-250 33⁄8 3⁄4 3 IB-300 41⁄16 3⁄4 31⁄2 IB-350 45⁄8 7⁄8
4 IB-400 51⁄8 7⁄8 5 IB-500 65⁄16 1 6 IB-600 77⁄16 1
Type PPC
Use:To plug bushings, rigid conduit and IMC.
Features:• Suitable for use on the following bushings: Type A, B, IBC, BB, IB, BLG, HB, HBLG and Type 2-series.
Material:Polyethylene
Applicable Third Party Standards:UL Listing not applicable
Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Max. Height
1⁄2 PPC-50 1 9⁄16 3⁄4 PPC-75 13⁄16 5⁄8 1 PPC-100 17⁄16 3⁄4
11⁄4 PPC-125 17⁄8 3⁄4 11⁄2 PPC-150 2 3⁄4 2 PPC-200 21⁄2 3⁄4
21⁄2 PPC-250 27⁄8 11⁄8 3 PPC-300 35⁄8 7⁄8
31⁄2 PPC-350 4 11⁄4 4 PPC-400 43⁄8 7⁄8
Insulating Bushings For Threaded for Rigid Conduit & IMC
Type IBThreaded
Type PPC
DB3 DB3
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type IBCThreaded (NPS)
Type IBC-SThreadless Set-Screw
Features:• UL temperature rating 150°C• Insulating liner material is UL V-O Rated (self extinguishing)• Plastic insulator is tough. It won’t chip, crack, swell or shrink. It resists corrosion, chemicals and temperature extremes. Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation.
Material/FinishMalleable Iron Body/Zinc PlatedThermoplastic Insulator
Third Party Certification:UL Listed: E-11853
CSA Certified: 009795
Applicable Third Party Standards:UL Standard: 514BCSA Standard: C22.2 No. 18Fed. Spec: W-F-408ENEMA: FB-1
Threaded Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Max. Height
1⁄2 IBC-50 13⁄16 1⁄2 3⁄4 IBC-75 17⁄16 9⁄16
1 IBC-100 13⁄4 5⁄8
11⁄4 IBC-125 21⁄8 3⁄4 11⁄2 IBC-150 25⁄16 7⁄8 2 IBC-200 213⁄16 15⁄16
21⁄2 IBC-250 33⁄8 1 3 IBC-300 41⁄16 11⁄8 31⁄2 IBC-350 41⁄2 13⁄16
4 IBC-400 53⁄16 15⁄16
5 IBC-500 61⁄16 15⁄16
6 IBC-600 71⁄4 15⁄16
Threadless Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Max. Height 1⁄2 IBC-50S 13⁄16 1⁄2 3⁄4 IBC-75S 17⁄16 9⁄16
1 IBC-100S 13⁄4 5⁄8
11⁄4 IBC-125S 21⁄8 3⁄4 11⁄2 IBC-150S 25⁄16 7⁄8 2 IBC-200S 213⁄16 15⁄16
21⁄2 IBC-250S 33⁄8 1 3 IBC-300S 41⁄16 11⁄8
31⁄2 IBC-350S 41⁄2 13⁄16
4 IBC-400S 53⁄16 15⁄16
Insulated Bushings For Rigid Conduit & IMC
Type IBCThreaded
Type IBC-SThreadless
DB4 DB4
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type IBC-L-ACThreaded with Aluminum Lay-In Lug™
Threaded (NPS)
Type IBC-LS-ACSet-Screw with Aluminum Lay-In Lug™
Threadless
Features:• UL temperature rating 150°C• Insulating liner material is UL V-O Rated (self extinguishing)• The plastic liner is tough. It won’t chip, crack, swell or shrink. It resists corrosion, chemicals and temperature extremes. Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation.• Set-Screw provided with each fitting locks bushing in any desired position.• UL Listed for use with copper or aluminum grounding conductors• Lugs not sold separately.
Material:Body - Malleable IronLug - AluminumClamping Screw - SteelSet Screws - Steel
Finish:Body - Zinc PlatedLug - Tin PlatedClamping Screw - Zinc PlatedSet Screws - Zinc Plated
Third Party Certification:UL Listed: E-24264
CSA Certified: 009795
Applicable Third Party Standards:UL Standard: 467CSA Standard: C22.2 No. 41Fed. Spec: W-F-408ENEMA: FB-1
Threadless Threaded Set Screw Dimensions in Inches Type Type Max. Turning Trade Size Catalog Catalog Grounding Wire Size Dia. Max. Radius (inches) Number Number Min. Max. without lug Ht. with lug
1⁄2 IBC-50L-4AC IBC-50LS-4AC 14 4 13⁄16 7⁄16 13⁄16
3⁄4 IBC-75L-4AC IBC-75LS-4AC 14 4 17⁄16 1⁄2 15⁄16
1 IBC-100L-4AC IBC-100LS-4AC 14 4 13⁄4 9⁄16 17⁄16
1 IBC-100L-20AC IBC-100LS-20AC 14 2/0 13⁄4 9⁄16 111⁄16
11⁄4 IBC-125L-4AC IBC-125LS-4AC 14 4 21⁄8 5⁄8 15⁄8 11⁄4 IBC-125L-20AC IBC-125LS-20AC 14 2/0 21⁄8 5⁄8 113⁄16
11⁄2 IBC-150L-4AC IBC-150LS-4AC 14 4 25⁄16 11⁄16 13⁄4 11⁄2 IBC-150L-20AC IBC-150LS-20AC 14 2/0 25⁄16 11⁄16 2
2 IBC-200L-4AC IBC-200LS-4AC 14 4 213⁄16 3⁄4 2 2 IBC-200L-20AC IBC-200LS-20AC 14 2/0 213⁄16 3⁄4 21⁄4
21⁄2 IBC-250L-4AC IBC-250LS-4AC 14 4 33⁄8 7⁄8 21⁄4 21⁄2 IBC-250L-20AC IBC-250LS-20AC 14 2/0 33⁄8 7⁄8 21⁄2 21⁄2 IBC-250L-25AC IBC-250LS-25AC 6 250 33⁄8 7⁄8 215⁄16
3 IBC-300L-4AC IBC-300LS-4AC 14 4 41⁄16 15⁄16 25⁄8 3 IBC-300L-20AC IBC-300LS-20AC 14 2/0 41⁄16 15⁄16 213⁄16
3 IBC-300L-25AC IBC-300LS-25AC 6 250 41⁄16 15⁄16 35⁄16
31⁄2 IBC-350L-4AC IBC-350LS-4AC 14 4 41⁄2 1 27⁄8 31⁄2 IBC-350L-20AC IBC-350LS-20AC 14 2/0 41⁄2 1 31⁄16
31⁄2 IBC-350L-25AC IBC-350LS-25AC 6 250 41⁄2 1 31⁄2
4 IBC-400L-4AC IBC-400LS-4AC 14 4 53⁄16 11⁄16 31⁄8 4 IBC-400L-20AC IBC-400LS-20AC 14 2/0 53⁄16 11⁄16 33⁄8 4 IBC-400L-25AC IBC-400LS-25AC 6 250 53⁄16 11⁄16 313⁄16
5 IBC-500L-4AC IBC-500LS-4AC 14 4 61⁄16 11⁄4 35⁄8 5 IBC-500L-20AC IBC-500LS-20AC 14 2/0 61⁄16 11⁄4 37⁄8 5 IBC-500L-25AC IBC-500LS-25AC 6 250 61⁄16 11⁄4 45⁄16
6 IBC-600L-4AC IBC-600LS-4AC 14 4 71⁄4 15⁄16 41⁄4 6 IBC-600L-20AC IBC-600LS-20AC 14 2/0 71⁄4 15⁄16 47⁄16
6 IBC-600L-25AC IBC-600LS-25AC 6 250 71⁄4 15⁄16 47⁄8
Type IBC-L-ACThreaded
Type IBC-LS-ACThreadless
Grounding Insulated Bushings with Aluminum Lug For Rigid Conduit & IMC
DB5 DB5
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type IBC-L-BCThreaded with Bronze Lay-In Lug™
Threaded (NPS)
Type IBC-LS-BCSet-Screw with Bronze Lay-In Lug™
Threadless
Features:• UL temperature rating 150°C• Insulating liner material is UL V-O Rated (self extinguishing)• The plastic liner is tough. It won’t chip, crack, swell or shrink. It resists corrosion, chemicals and temperature extremes. Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation.• Set-screw provided with each fitting locks bushing in any desired position.• UL Listed for use with copper grounding conductors only.• Lugs not sold separately.
Material:Body - Malleable IronLug - BronzeClamping Screw - SteelSet Screws - Steel
Finish:Body - Zinc PlatedLug - Bright DipClamping Screw - Zinc PlatedSet Screws - Zinc Plated
Third Party Certification:UL Listed: E-24264
CSA Certified: 009795
Applicable Third Party Standards:UL Standard: 467CSA Standard: C22.2 No. 41Fed. Spec: W-F-408ENEMA: FB-1
Threadless Threaded Set Screw Dimensions in Inches Type Type Max. Turning Trade Size Catalog Catalog Grounding Wire Size Dia. Max. Radius (inches) Number Number Min. Max. without lug Ht. with lug
1⁄2 IBC-50L-4BC IBC-50LS-4BC 14 4 13⁄16 7⁄16 13⁄16
3⁄4 IBC-75L-4BC IBC-75LS-4BC 14 4 17⁄16 1⁄2 15⁄16
1 IBC-100L-4BC IBC-100LS-4BC 14 4 13⁄4 9⁄16 17⁄16
1 IBC-100L-20BC IBC-100LS-20BC 14 2/0 13⁄4 9⁄16 111⁄16
11⁄4 IBC-125L-4BC IBC-125LS-4BC 14 4 21⁄8 5⁄8 15⁄8 11⁄4 IBC-125L-20BC IBC-125LS-20BC 14 2/0 21⁄8 5⁄8 113⁄16
11⁄2 IBC-150L-4BC IBC-150LS-4BC 14 4 25⁄16 11⁄16 13⁄4 11⁄2 IBC-150L-20BC IBC-150LS-20BC 14 2/0 25⁄16 11⁄16 2
2 IBC-200L-4BC IBC-200LS-4BC 14 4 213⁄16 3⁄4 2 2 IBC-200L-20BC IBC-200LS-20BC 14 2/0 213⁄16 3⁄4 21⁄4
21⁄2 IBC-250L-4BC IBC-250LS-4BC 14 4 33⁄8 7⁄8 21⁄4 21⁄2 IBC-250L-20BC IBC-250LS-20BC 14 2/0 33⁄8 7⁄8 21⁄2 21⁄2 IBC-250L-25BC IBC-250LS-25BC 6 250 33⁄8 7⁄8 215⁄16
3 IBC-300L-4BC IBC-300LS-4BC 14 4 41⁄16 15⁄16 25⁄8 3 IBC-300L-20BC IBC-300LS-20BC 14 2/0 41⁄16 15⁄16 213⁄16
3 IBC-300L-25BC IBC-300LS-25BC 6 250 41⁄16 15⁄16 35⁄16
31⁄2 IBC-350L-4BC IBC-350LS-4BC 14 4 41⁄2 1 27⁄8 31⁄2 IBC-350L-20BC IBC-350LS-20BC 14 2/0 41⁄2 1 31⁄16
31⁄2 IBC-350L-25BC IBC-350LS-25BC 6 250 41⁄2 1 31⁄2
4 IBC-400L-4BC IBC-400LS-4BC 14 4 53⁄16 11⁄16 31⁄8 4 IBC-400L-20BC IBC-400LS-20BC 14 2/0 53⁄16 11⁄16 33⁄8 4 IBC-400L-25BC IBC-400LS-25BC 6 250 53⁄16 11⁄16 313⁄16
5 IBC-500L-4BC IBC-500LS-4BC 14 4 61⁄16 11⁄4 35⁄8 5 IBC-500L-20BC IBC-500LS-20BC 14 2/0 61⁄16 11⁄4 37⁄8 5 IBC-500L-25BC IBC-500LS-25BC 6 250 61⁄16 11⁄4 45⁄16
6 IBC-600L-4BC IBC-600LS-4BC 14 4 71⁄4 15⁄16 41⁄4 6 IBC-600L-20BC IBC-600LS-20BC 14 2/0 71⁄4 15⁄16 47⁄16
6 IBC-600L-25BC IBC-600LS-25BC 6 250 71⁄4 15⁄16 47⁄8
Type IBC-L-BCThreaded
Type IBC-LS-BCThreadless
Grounding Insulated Bushings with Bronze Lug For Rigid Conduit & IMC
DB6 DB6
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type 1Conduit Locknut
Material:3⁄8” through 6” - Heavy Stock Steel
Finish: Zinc Plated
Optional Finish:For additional corrosion protection, specify Mechanically GalvanizedContact your local representative for pricing and availability.
Third Party Certification:UL Listed: E-11853
CSA Certified: 057250 & 009795
Applicable Third Party Standards:UL Standard: 514BCSA Standard: C22.2 No. 18Fed. Spec: W-F-408E; NEMA: FB-1
Dia. Trade Size Catalog Threads Across (inches) Number Per Inch Thickness Flats
3⁄8 1-38S* 18 1⁄8 7⁄8 1⁄2 1-50S 14 1⁄8 111⁄16
3⁄4 1-75S 14 1⁄8 11⁄4 1 1-100S 111⁄2 3⁄16 15⁄8
11⁄4 1-125S 111⁄2 3⁄16 21⁄64
11⁄2 1-150S 111⁄2 3⁄16 21⁄4 2 1-200S 111⁄2 3⁄16 23⁄4
21⁄2 1-250 8 3⁄8 39⁄16
3 1-300 8 3⁄8 41⁄4 31⁄2 1-350 8 3⁄8 413⁄16
4 1-400 8 3⁄8 59⁄16
5 1-500 8 1⁄2 611⁄16
6 1-600 8 1⁄2 715⁄16
Material: Aluminum
Third Party Certification:UL Listed: E-11853
CSA Certified: 009795 & 067549
Applicable Third Party Standards:UL Standard: 514BCSA Standard: C22.2 No. 18Fed. Spec: W-F-408E NEMA: FB-1
Dia. Trade Size Catalog Threads Across (inches) Number Per Inch Thickness Flats
1⁄2 1-50A 14 3⁄16 11⁄8 3⁄4 1-75A 14 3⁄16 17⁄16
1 1-100A 111⁄2 3⁄16 113⁄16
11⁄4 1-125A 111⁄2 3⁄16 39⁄32
11⁄2 1-150A 111⁄2 3⁄16 219⁄32
2 1-200A 111⁄2 3⁄16 33⁄16
21⁄2 1-250A 8 3⁄8 39⁄16 3 1-300A 8 3⁄8 41⁄4 31⁄2 1-350A 8 3⁄8 413⁄16
4 1-400A 8 3⁄8 57⁄16 5 1-500A 8 1⁄2 611⁄16
6 1-600A 8 1⁄2 715⁄16
*Square Style
Standard Conduit LocknutsThreaded For Rigid Conduit & IMC
Type 1Steel & Aluminum
DB7 DB7
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Conduit Locknuts & Fixture NutsThreaded For Rigid Conduit & IMC
Type 1-38LOSOversize Locknut 3⁄8” covers 1⁄2” KO
Material/Finish: Steel/Zinc Plated
Type 1-18SFixture Nuts
Material/Finish:Steel/Zinc Plated
Dimensions in Inches Trade Threads Dia. Dia. Size Catalog K.O. Per Across Across (inches) Number Size Inch Thkns. Corners Flats
3⁄8 1-38LOS 3⁄8 & 1⁄2 18 1⁄8 11⁄8 11⁄16
Dimensions in Inches Threads Dia. Dia. Trade Size Catalog Per Across Across (inches) Number Inch Thkns Corners Flats
1⁄8 1-18S 27 1⁄8 5⁄8 9⁄16
1⁄4 1-25S 18 1⁄8 3⁄4 11⁄16
Type 1-18S
Type 1-38LOS
DB8 DB8
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type 101Bonding Wedge Locknut
Use:Use with bushings to bond 1⁄2” through 6” rigid conduit and IMC to boxes, cabinets or other enclosures.
Material/Finish:Steel/Zinc Electroplated
Third Party Certification:UL Listed: E-24264
CSA Certified: 9795
Applicable Third Party Standards:UL Standard: 467CSA Standard: C22.2 No. 41Fed. Spec: W-F-408ENEMA: FB-1
Trade Size Catalog Max. (inches) Number Dia. Thickness Radius
1⁄2 101 13⁄16 3⁄16 15⁄16 3⁄4 102 13⁄8 3⁄16 15⁄16
1 103 111⁄16 3⁄16 11⁄16
11⁄4 104 21⁄16 3⁄16 11⁄4 11⁄2 105 23⁄8 3⁄16 17⁄16
2 106 27⁄8 3⁄16 15⁄8
21⁄2 107 33⁄8 3⁄8 115⁄16
3 108 41⁄4 3⁄8 21⁄2 31⁄2 109 413⁄16 3⁄8 21⁄2
4 110 55⁄16 3⁄8 27⁄8 5 112* 7 1⁄2 31⁄2 6 113* 81⁄8 1⁄2 41⁄16
*Not CSA Certified
Type SLGSealing Locknut
Features:• Supplied with integrally fused PVC gasket• Provides raintight or oil tight seal
Material/Finish:Steel/Zinc-Plated
Third Party Certification:UL Listed: E-11853
CSA Certified: 057250
Applicable Third Party Standards: UL Standard: 514BCSA Standard: C22.2 No. 18Fed. Spec: W-F-408ENEMA: FB-1
Trade Size Catalog Threads Max. (inches) Number Per Inch Diameter Thickness
1⁄2 SLG-50S 14 11⁄8 1⁄8
3⁄4 SLG-75S 14 13⁄8 1⁄8
1 SLG-100S 111⁄2 13⁄4 3⁄16
11⁄4 SLG-125S 111⁄2 21⁄16 3⁄16
11⁄2 SLG-150S 111⁄2 23⁄8 3⁄16
2 SLG-200S 111⁄2 27⁄8 3⁄16
21⁄2 SLG-250S 8 37⁄16 3⁄8 3 SLG-300S 8 41⁄8 3⁄8 31⁄2 SLG-350S 8 45⁄8 3⁄8 4 SLG-400S• 8 51⁄4 3⁄8
•Not certified UL or CSA
Bonding Conduit Locknuts & Sealing LocknutsThreaded For Rigid Conduit & IMC
Type 101
Type SLG
DB9 DB9
Effective December, 2007Copyright 2007
800-621-1506www.o-zgedney.com
Standard Bushings — Standard Locknuts
Type RW
Use:To reduce a knockout or sliphole in a sheet metal enclosure to a smaller trade size.
Material/Finish:Steel/Zinc Pre-Galvanized
Third Party Certification:UL Listed: E11857
CSA Certified: 057250
Applicable Third Party Standards:UL Standard: 514BCSA Standard: C22.2 No. 18NEMA: FB-1
Note:Two reducing washers are required for each knockout.
•Not CSA Certified.
Reducing Washers
Type RW
Trade Size Catalog Dimensions in Inches (inches) Number A B
3⁄4 x 1⁄2 RW-2S 0.88 1.44 1 x 1⁄2 RW-3S 0.88 1.75 1 x 3⁄4 RW-4S 1.11 1.75
11⁄4 x 1⁄2 RW-5S 0.88 2.19 11⁄4 x 3⁄4 RW-6S 1.11 2.19 11⁄4 x 1 RW-7S 1.37 2.19 11⁄2 x 1⁄2 RW-8S 0.88 2.50 11⁄2 x 3⁄4 RW-9S 1.11 2.50 11⁄2 x 1 RW-10S 1.37 2.50 11⁄2 x 11⁄4 RW-11S 1.73 2.50 2 x 1⁄2 RW-12S 0.88 3.00 2 x 3⁄4 RW-13S 1.11 3.00 2 x 1 RW-14S 1.37 3.00 2 x 11⁄4 RW-15S 1.73 3.00 2 x 11⁄2 RW-16S 1.98 3.00
21⁄2 x 1⁄2 RW-17S 0.88 3.50 21⁄2 x 3⁄4 RW-18S 1.11 3.50 21⁄2 x 1 RW-19S 1.37 3.50 21⁄2 x 11⁄4 RW-20S 1.73 3.50 21⁄2 x 11⁄2 RW-21S 1.98 3.50 21⁄2 x 2 RW-22S 2.45 3.50
3 x 1 RW-25S 1.37 4.13 3 x 11⁄4 RW-26S 1.73 4.13 3 x 11⁄2 RW-27S 1.98 4.13 3 x 2 RW-28S 2.45 4.13 3 x 21⁄2 RW-29S 2.97 4.13 31⁄2 x 11⁄2 RW-34S• 1.98 4.63 31⁄2 x 2 RW-35S• 2.45 4.63 31⁄2 x 21⁄2 RW-36S• 2.97 4.63 31⁄2 x 3 RW-37S• 3.59 4.63 4 x 2 RW-43S• 2.50 5.15 4 x 21⁄2 RW-44S• 2.97 5.15 4 x 3 RW-45S• 3.59 5.15 4 x 31⁄2 RW-46S• 4.13 5.15