MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
SLOTTED ACOUSTIC PANEL SYSTEM
REPORT NUMBER:
4600 REV A
PREPARED FOR:
Supawood Architectural Lining Systems 18 Bradwardine Road Bathurst NSW 2795 Attention: Mr Colin Beattie Telephone: (02) 6333 8000
DATE ISSUED: 8 October 2013
Report Status Prepared by: Phillip Lu Approved by: Stephen Gauld
Final
Document R\4600-r1 rev a, 22 pages plus attachments
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 2
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
TABLE OF CONTENTS
1.0 INTRODUCTION ....................................................................................................3
2.0 SOUND SURVEY INSTRUMENTATION ..........................................................3
3.0 ACOUSTIC TEST LABORATORY .....................................................................4
4.0 MEASUREMENT PROCEDURE ..........................................................................5 4.1 Sound Absorption Coefficients (αs) ....................................................................................... 6 4.2 Practical Sound Absorption Coefficients (αp) ........................................................................ 6 4.3 Weighted Sound Absorption Coefficient (αw) ....................................................................... 6 4.4 Shape Indicators ..................................................................................................................... 7 4.5 Noise Reduction Coefficient (NRC) ....................................................................................... 7
5.0 TEST SPECIMEN DESCRIPTIONS AND RESULTS ......................................8
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 3
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
1.0 INTRODUCTION
Day Design was commissioned by Supawood Architectural Lining Systems to measure the sound absorption coefficients for a range of their slotted timber panels.
The tests were conducted in a reverberation chamber at the National Acoustic Laboratories in accordance with Australian Standard AS ISO 354-2006: “Acoustics – Measurement of sound absorption in a reverberation room”.
The measurement results were rated in accordance with AS ISO 11654-2002” “Acoustics – Rating of Sound Absorption – Materials and Systems”.
2.0 SOUND SURVEY INSTRUMENTATION
Noise level measurements and analysis were made with instrumentation as follows in Table 2.1:
Table 2.1 Instrumentation
Description Serial No.
Brüel and Kjær Two Channel Pulse Analyser (assembly 2825, 7521, 2 x 3015)
Brüel and Kjær Cathode Follower type 2660
Brüel and Kjær Microphone type 4179
Brüel and Kjær Sound Level Calibrator type 4231
Yamaha Professional Sound Sources type S500 (2x units)
Murray 100 Watt Amplifier type MA534
Vaisala Digital Barometer type PTB201AD
Testo Temperature/Humidity Logger, type 177-H1
2005502
1338051
2245154
2095415
1068 & 1069
15
R3330001
00886924
All acoustic instrument systems have been laboratory calibrated using instrumentation traceable to Australian National Standards and certified within the last two years thus conforming to Australian Standards. The acoustic measurement system was also calibrated prior to and after the noise level measurements.
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 4
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
3.0 ACOUSTIC TEST LABORATORY
Location: National Acoustic Laboratories
126 Greville Street, Chatswood, NSW.
Room Construction: The Receiving Reverberation Room was used for the acoustical measurements with the dividing steel doors closed. The room is of concrete and masonry construction having an internal volume of 202 cubic metres. The floor is pentagonally shaped and the ceiling is inclined so that no two surfaces are parallel. The room is vibration and sound isolated from the enclosing building, being floated on steel springs and rubber dampers below the concrete floor.
Large panels of 19 mm thick plywood, heavily coated with an epoxy resin are suspended inside the test room in random orientation to aid in the diffusion of the sound field.
Room Surface Area: 231 m2
Atmospheric Conditions:
The relative humidity inside the reverberation room throughout testing was approximately 55%. The temperature was 21oC.
Test Specimens: - 12 mm Parallel-slotted MDF panels with acoustic backing.
- 12 mm V-slotted MDF panels with acoustic backing.
- Tested with various air-spaces behind.
Date of Tests: Thursday 14th April, 2011
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 5
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
4.0 MEASUREMENT PROCEDURE
Before testing commenced, the reverberation room temperature, relative humidity and barometric air pressure were noted (refer attached spreadsheet). The measurement microphone was acoustically calibrated and the acoustical noise floor of the room checked.
AS ISO 354-2006 requires the area of plane absorber test specimens to be between 10 m2 to 12 m2.
All reverberation rooms have small space variations of the sound field distribution and time variations in sound field decay (of reverberation time) during the measurement period. The gathering of meaningful results therefore requires multiple measurements to determine the extent of these variations. The testing procedure uses 48 sets of data to determine the spread of results around the estimate of the mean, each set containing eighteen measurements of one-third-octave reverberation times (refer attached spreadsheet).
Sound levels generated in the reverberation room for this test were at least 48 dB above the combined background noise level in the reverberation room and the recording equipment electrical noise level for each one-third-octave band. Thus these tests provide a minimum 33 dB evaluation range for measurement of sound decay starting from 5 dB below the initial sound pressure level and with a margin of at least 10 dB between the background noise level and the lowest level of measurement. Item 7.4.1 of AS ISO 354-2006 requires a minimum evaluation range of 20 dB.
The suite of data is divided into two sets of 24 measurements; the first set for the empty reverberation room; and the second set for the reverberation room with the test specimen. The difference between the two measurement data sets is used to determine the absorption characteristics of the test specimen.
These 24 sets of data for each of the two measurement suites consists of a spatial average of six different combinations of two loudspeakers and three microphone positions, and four measurements taken at each combination for a time average to obtain an estimate of the reverberation time precision.
At all times care was taken to ensure that the microphone was separated by at least one metre from the test specimen and room surfaces or diffusers and at least two metres from a sound source as required by AS ISO 354-2006.
This space-time measurement data was computer processed on a pre-configured Excel spreadsheet to obtain a final average and standard deviation for the test specimen results. The calculations provide sound absorption coefficients and precision level of the measurements to a 95% confidence level.
The complete measurement data, calculated sound absorption coefficients and the precision of each coefficient to the 95% confidence level is shown on the attached spreadsheets and is tabulated throughout this report.
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 6
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Note: The first measurement of empty room reverberation time can be used for measurements involving more than one test specimen since the temperature and humidity are stable over long periods of time in all of the test facility measurement rooms. However, re-measurement of the empty room reverberation time is always undertaken if the data is suspect or multiple samples are to be evaluated over a long period of time.
4.1 Sound Absorption Coefficients (αs)
The sound absorption coefficient (αs) in one-third-octave bands (centre frequencies of 100 to 500 Hz inclusive) is the ratio of the equivalent sound absorption area of a test specimen divided by the area of the test specimen. It should be noted that a sound absorption coefficient evaluated from reverberation time measurements can have values larger than 1.00 due to edge effects. Sound absorption coefficient results were rounded to the nearest 0.01 as required by AS ISO 354-2006, item 8.3.
4.2 Practical Sound Absorption Coefficients (αp)
The practical sound absorption coefficient (αp) is given in octave bands (centre frequencies of 125 to 4000 Hz inclusive) based on the arithmetic mean value of the three corresponding one-third-octave sound absorption coefficients, with the mean value calculated to the second decimal, rounded in steps of 0.05.
4.3 Weighted Sound Absorption Coefficient (αw)
The weighted sound absorption coefficient (αw) is calculated from the practical sound absorption coefficients (αp) using the reference curve as shown in Table 1 below. The reference curve is shifted in steps of 0.05 towards the measured αp value, until the sum of the unfavourable deviations is less than 0.10. An unfavourable deviation occurs at a particular frequency when the measured value is less than the value of the reference curve. The weighted sound absorption coefficient αw is defined as the value of the shifted reference curve at 500 Hz.
Table 1 Reference curve for evaluation of weighted sound absorption coefficient, αw
Frequency (Hz) 250 500 1000 2000 4000
Value 0.80 1.00 1.00 1.00 0.90
The single number rating, αw, obtained by the method of this standard does not convey enough information when products are to be used in environments requiring specialist acoustical design. In such cases, complete sound absorption data, αs, as a function of frequency are needed.
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 7
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
4.4 Shape Indicators
Whenever αp exceeds the value of the shifted reference curve by 0.25 or more, one or more shape indicators are added in parentheses, to the single number αw rating. If the excess absorption occurs at 250 Hz, “(L)” notation is used. If the excess absorption occurs at 500 Hz or 1000 Hz, “(M)” notation is used. If the excess absorption occurs at 2000 Hz or 4000 Hz, “(H)” notation is used. A “shape indicator” means the sound absorption coefficient at one or more frequencies is considerably higher than the values of the shifted reference curve and therefore, the complete sound absorption coefficient curve should be examined.
4.5 Noise Reduction Coefficient (NRC)
The noise reduction coefficient (NRC) is a commonly used descriptor determined by arithmetically averaging the sound absorption coefficients measured in octave bands centred on 250 – 2000 Hz inclusive, as defined in the American Standard ASTM C 423–89: “Standard test method for sound absorption and sound absorption coefficients by the reverberation room method”. The calculated NRC is rounded to the nearest 0.05.
The NRC is not defined by Australian Standards. However, we have included the NRC rating in this report, for comparison with other test data.
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 8
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
5.0 TEST SPECIMEN DESCRIPTIONS AND RESULTS
Each test specimen comprised of six or eight 1.19 m x 1.19 m panels. Two types of panels (Parallel-slotted and V-slotted) were combined with the following mountings:
• NCK LOW, Type E-25 (eight panels)
• NCK MEDIUM, Type E-55 (eight panels)
• NCK HIGH, Type E-100 (eight panels)
• NCK SAWTOOTH, Type E-60 to 200(eight panels)
All tested with and without insulation and,
• NCK FLOAT, Type G-400 (six panels)
Tested with insulation.
Type E Mounting denotes that the test specimen was installed with an air-space behind it. The size of the air-space is indicated by the number (to the nearest 5 mm) following the mounting type descriptor e.g. Type E-25.
Where a Sawtooth frame was used, the mounting type is rated as Type E-60 to 200 where the minimum air-space is 60 mm and the maximum air-space is 200 mm as shown in the figure below.
Type G Mounting denotes that the test specimen is hung parallel to the room surface. The distance from the face of the test specimen to the room surface is indicated by the number (multiple of 50 mm) following the mounting type descriptor e.g. Type G-400.
In this instance panels were raised from the floor by 415 mm to simulate them hanging from a soffit. The edges were not closed in to allow sound absorption around the edges of each panel.
The NRC and αw rating of the test specimens are presented in Tables 5.1 – 5.10 below.
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 9
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.1 NCK LOW – Type E-25 Mounting
Test Specimen Panel
Noise Reduction Coefficient
(NRC)
Weighted Sound
Absorption Coefficient (αw)
NCK LOW Parallel-slotted
25 mm air-space No insulation
0.45 0.45
NCK LOW V-slotted
25 mm air-space No Insulation
0.40 0.30 (MH)
NCK LOW Parallel-slotted
25 mm air-space VHP25 Insulation
0.55 0.60
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 10
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
NCK LOW V-slotted
25 mm air-space VHP25 Insulation
0.75 0.75
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 11
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.2 NCK LOW - Measured Sound Absorption Coefficients
1/3 Octave Band
Centre Frequency
(Hz)
Sound Absorption Coefficients
NCK LOW Parallel-slotted
25 mm air-space No insulation
NCK LOW V-slotted
25 mm air-space No Insulation
NCK LOW Parallel-slotted
25 mm air-space VHP25 Insulation
NCK LOW V-slotted
25 mm air-space VHP25 Insulation
100 0.04 0.04 0.12 0.08 125 0.08 0.08 0.17 0.12
160 0.15 0.11 0.39 0.28
200 0.17 0.11 0.44 0.33 250 0.20 0.13 0.53 0.44
315 0.30 0.18 0.58 0.63
400 0.33 0.18 0.57 0.75 500 0.41 0.22 0.61 0.79
630 0.47 0.26 0.58 0.83
800 0.51 0.49 0.57 0.87 1000 0.55 0.67 0.60 0.87
1250 0.60 0.72 0.58 0.88
1600 0.64 0.71 0.57 0.86 2000 0.65 0.70 0.59 0.83
2500 0.56 0.62 0.56 0.84
3150 0.48 0.57 0.56 0.78 4000 0.49 0.49 0.61 0.65
5000 0.60 0.59 0.71 0.63
NRC 0.45 0.40 0.55 0.75
αw 0.45 0.30 (MH) 0.60 0.75
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 12
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.3 NCK MEDIUM - Type E-55 Mounting
Test Specimen Panel
Noise Reduction Coefficient
(NRC)
Weighted Sound Absorption
Coefficient (αw)
NCK MEDIUM Parallel-slotted
55 mm air-space No insulation
0.55 0.60
NCK MEDIUM V-slotted
55 mm air-space No insulation
0.50 0.55
NCK MEDIUMI Parallel-slotted
55 mm air-space HP50 Insulation
0.65 0.65
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 13
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
NCK MEDIUM V-slotted
55 mm air-space HP50 Insulation
0.75 0.75
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 14
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.4 NCK MEDIUM - Measured Sound Absorption Coefficients
1/3 Octave Band
Centre Frequency
(Hz)
Sound Absorption Coefficients
NCK MEDIUM Parallel-slotted
55 mm air-spaceNo insulation
NCK MEDIUM V-slotted
55 mm air-spaceNo insulation
NCK MEDIUM Parallel-slotted
55 mm air-space HP50 Insulation
NCK MEDIUM V-slotted
55 mm air-spaceHP50 Insulation
100 0.18 0.14 0.37 0.25 125 0.20 0.12 0.36 0.24
160 0.34 0.27 0.59 0.49
200 0.38 0.26 0.61 0.53 250 0.46 0.31 0.63 0.62
315 0.55 0.40 0.70 0.74
400 0.52 0.42 0.67 0.84 500 0.61 0.47 0.69 0.95
630 0.64 0.56 0.69 0.98
800 0.66 0.63 0.69 0.86 1000 0.65 0.70 0.67 0.78
1250 0.66 0.69 0.64 0.74
1600 0.60 0.64 0.61 0.70 2000 0.60 0.57 0.59 0.63
2500 0.45 0.50 0.49 0.61
3150 0.41 0.53 0.47 0.65 4000 0.47 0.51 0.51 0.61
5000 0.61 0.55 0.64 0.63
NRC 0.55 0.50 0.65 0.75
αw 0.60 0.55 0.65 0.75
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 15
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.5 NCK HIGH - Type E-100 Mounting
Test Specimen Panel
Noise Reduction Coefficient
(NRC)
Weighted Sound
Absorption Coefficient (αw)
NCK HIGH Parallel-slotted
98 mm air-space No insulation
0.60 0.60
NCK HIGH V-slotted
98 mm air-space No insulation
0.60 0.60
NCK HIGH Parallel-slotted
98 mm air-space HP50 Insulation
0.65 0.65
NCK HIGH V-slotted
98 mm air-space HP50 Insulation
0.75 0.70 (L)
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 16
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.6 NCK HIGH - Measured Sound Absorption Coefficients
1/3 Octave Band
Centre Frequency
(Hz)
Sound Absorption Coefficients
NCK HIGH Parallel-slotted
98 mm air-space No insulation
NCK HIGH V-slotted
98 mm air-space No insulation
NCK HIGH Parallel-slotted
98 mm air-space HP50 Insulation
NCK HIGH V-slotted
98 mm air-space HP50 Insulation
100 0.47 0.29 0.54 0.38
125 0.41 0.26 0.47 0.35
160 0.59 0.47 0.72 0.59
200 0.61 0.51 0.66 0.68
250 0.63 0.60 0.67 0.79
315 0.62 0.68 0.69 0.87
400 0.64 0.64 0.67 0.93
500 0.70 0.70 0.69 0.96
630 0.67 0.58 0.70 0.87
800 0.63 0.57 0.66 0.69
1000 0.62 0.59 0.64 0.65
1250 0.61 0.57 0.61 0.62
1600 0.53 0.50 0.55 0.63
2000 0.50 0.47 0.54 0.65
2500 0.48 0.55 0.50 0.67
3150 0.43 0.57 0.47 0.66
4000 0.49 0.51 0.54 0.62
5000 0.62 0.59 0.67 0.63
NRC 0.60 0.60 0.65 0.75
αw 0.60 0.60 0.65 0.70 (L)
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 17
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.7 NCK SAWTOOTH – Type E-60 to 200
Test Specimen Panel
Noise Reduction Coefficient
(NRC)
Weighted Sound
Absorption Coefficient (αw)
NCK Parallel-slotted SAWTOOTH No Insulation
0.60 0.60
NCK V-slotted
SAWTOOTH No Insulation
0.60 0.60 (L)
NCK Parallel-slotted SAWTOOTH
HP50 Insulation
0.65 0.60 (L)
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 18
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
NCK V-slotted
SAWTOOTH HP50 Insulation
0.75 0.70 (L)
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 19
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.8 NCK SAWTOOTH Measured Sound Absorption Coefficients
1/3 Octave Band Centre Frequency
(Hz)
Sound Absorption Coefficients
NCK Parallel-slotted SAWTOOTH No Insulation
NCK V-slotted
SAWTOOTH No Insulation
NCK Parallel-slotted SAWTOOTH
HP50 Insulation
NCK V-slotted
SAWTOOTH HP50 Insulation
100 0.47 0.36 0.51 0.50125 0.50 0.42 0.48 0.51160 0.60 0.57 0.67 0.75200 0.53 0.56 0.58 0.80250 0.62 0.64 0.65 0.85315 0.62 0.70 0.69 0.96400 0.65 0.71 0.71 1.01500 0.63 0.72 0.70 0.95630 0.64 0.55 0.64 0.76800 0.65 0.54 0.65 0.64
1000 0.60 0.55 0.60 0.631250 0.60 0.57 0.59 0.651600 0.53 0.57 0.56 0.672000 0.53 0.56 0.59 0.672500 0.50 0.57 0.53 0.693150 0.48 0.61 0.54 0.704000 0.53 0.59 0.57 0.665000 0.69 0.65 0.71 0.70
NRC 0.60 0.60 0.65 0.75
αw 0.60 0.60 (L) 0.60 (L) 0.70 (L)
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 20
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.9 NCK FLOAT – Type G-400
Test Specimen Description
Noise Reduction Coefficient
(NRC)
Sound Absorption Coefficient
(αw)
NCK FLOAT* (430 BFCL)
Parallel-slotted 415 mm air-space HP50 Insulation
Separated by 340 mm
0.80 0.85
NCK FLOAT* (430 BFCL)
V-slotted 415 mm air-space HP50 Insulation
Separated by 340 mm
0.80 0.85
* Simulates floating panels that are suspended from a ceiling. Panels were tested in a 11.6 m2 area with six panels contributing 8.5m2 and the floor 3.1 m2. Panels were separated with a gap of 340 mm. The αw and NRC of the panels were calculated with the specimen surface area of 11.6 m2.
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 21
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Table 5.10 NCK FLOAT Measured Sound Absorption Coefficients
1/3 Octave Band Centre Frequency
(Hz)
Sound Absorption Coefficients
NCK FLOAT* (430 BFCL) Parallel-slotted 415 mm air-gap HP50 Insulation
Separated by 340 mm
NCK FLOAT* (430 BFCL) V-slotted
415 mm air-gap HP50 Insulation
Separated by 340 mm
100 0.23 0.23 125 0.34 0.31
160 0.58 0.55
200 0.60 0.71 250 0.72 0.80
315 0.76 0.85
400 0.76 0.77 500 0.79 0.72
630 0.81 0.80
800 0.82 0.81 1000 0.86 0.86
1250 0.83 0.88
1600 0.83 0.84 2000 0.79 0.87
2500 0.75 0.83
3150 0.71 0.86 4000 0.79 0.86
5000 0.92 0.90
NRC 0.80 0.80
αw 0.85 0.85
* Simulates floating panels that are suspended from a ceiling. Panels were tested in a 11.6 m2 area with six panels contributing 8.5m2 and the floor 3.1 m2. Panels were separated with a gap of 340 mm. The αw and NRC of the panels were calculated with the specimen surface area of 11.6 m2.
DAY DESIGN PTY LTD MEASUREMENTS OF SOUND ABSORPTION COEFFICIENTS Report 4600 Rev A Page 22
Document: 4600-r1 rev a
SUPAWOOD ARCHITECTURAL LINING SYSTEMS
8 Oct 13
Sound absorption coefficients (rounded to the nearest 0.01) are tabulated for each one-third-octave band tested and presented in the Tables above. Formulae used in deriving results are presented in the attached Appendix A.
Reverberation times at one-third octave centre frequencies 100 to 5000 Hz were measured and sound absorption coefficients calculated by the methods and procedures of AS ISO 11654-2002: “Acoustics – Rating of Sound Absorption – Materials and Systems”.
Test measurements and calculations were conducted by the undersigned.
Phillip Lu, BSc (Physics)
Acoustical Scientist for and on behalf of Day Design Pty Ltd.
AAAC MEMBERSHIP
Day Design Pty Ltd is a member company of the Association of Australian Acoustical Consultants, and the work herein reported has been performed in accordance with the terms of membership.
Attachments:
• Appendix A: Method of Calculation of Sound Absorption Coefficients
• Test Certificates 4600A – 4600R – Slotted Panels
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK LOW18 Bradwardine Road, Bathurst, NSW, 2795 25 mm air-space
Parallel - Slotted
ααααs ααααp Australian Standards: 0.04 Measured according to AS ISO 354-20060.08 0.10 Rated according to AS ISO 11654-20020.150.17 Specimen Area:0.20 0.20 11.3 m2 (4.76 m x 2.38 m)0.300.33 Mounting:0.41 0.40 Type E-250.470.51 Test Location:0.55 0.55 Twin Reverberation Rooms0.60 National Acoustic Laboratories0.64 126 Greville Street, Chatswood NSW0.65 0.600.56 Instrumentation:0.48 - Brüel and Kjær Two Channel Pulse Analyser 0.48 0.50 (assembly 2825, 7521, 2 x 3015)
16002000
630800
100
10001250
25003150
Test 4600A
Sound Absorption Coefficients
4000
Frequency - Hz
160200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
125
400500
SOUND ABSORPTIONTEST CERTIFICATE
0.48 0.50 (assembly 2825, 7521, 2 x 3015)
0.60 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600A For and on behalf of Day Design Pty LtdThursday, 14 April 2011
Noise Reduction Coefficient, NRC 0.45
Weighted Sound Absorption Coefficient, ααααw 0.45
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK LOW18 Bradwardine Road, Bathurst, NSW, 2795 25 mm air-space
V - Slotted
ααααs ααααp Australian Standards:
0.04 Measured according to AS ISO 354-2006
0.08 0.10 Rated according to AS ISO 11654-20020.110.11 Specimen Area:
0.13 0.15 11.3 m2 (4.76 m x 2.38 m)0.180.18 Mounting:
0.22 0.20 Type E-25
0.260.49 Test Location:
0.67 0.65 Twin Reverberation Rooms0.72 National Acoustic Laboratories
0.71 126 Greville Street, Chatswood NSW
0.70 0.700.62 Instrumentation:
0.57 - Brüel and Kjær Two Channel Pulse Analyser
0.49 0.55 (assembly 2825, 7521, 2 x 3015)
630800
16002000
10001250
25003150
Test 4600B
Sound Absorption Coefficients
4000
Frequency - Hz
SOUND ABSORPTIONTEST CERTIFICATE
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
0.49 0.55 (assembly 2825, 7521, 2 x 3015)
0.59 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600B For and on behalf of Day Design Pty Ltd
Noise Reduction Coefficient, NRC 0.40
Weighted Sound Absorption Coefficient, ααααw 0.30 (MH)
Thursday, 14 April 2011
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK LOW18 Bradwardine Road, Bathurst, NSW, 2795 25 mm air-space
Parallel - SlottedVHP25 Insulation
ααααs ααααp Australian Standards: 0.12 Measured according to AS ISO 354-20060.17 0.20 Rated according to AS ISO 11654-20020.390.44 Specimen Area:0.53 0.50 11.3 m2 (4.76 m x 2.38 m)0.580.57 Mounting:0.61 0.60 Type E-250.580.57 Test Location:0.60 0.60 Twin Reverberation Rooms0.58 National Acoustic Laboratories0.57 126 Greville Street, Chatswood NSW0.59 0.600.56 Instrumentation:0.56 - Brüel and Kjær Two Channel Pulse Analyser 0.61 0.65 (assembly 2825, 7521, 2 x 3015)
Test 4600C
Sound Absorption Coefficients
4000
Frequency - Hz
160200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
125
400500
SOUND ABSORPTIONTEST CERTIFICATE
100
16002000
630800
10001250
25003150
0.61 0.65 (assembly 2825, 7521, 2 x 3015)
0.71 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600C For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
Noise Reduction Coefficient, NRC 0.55
Weighted Sound Absorption Coefficient, ααααw 0.60
5000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK LOW18 Bradwardine Road, Bathurst, NSW, 2795 25 mm air-space
V - SlottedVHP25 Insulation
ααααs ααααp Australian Standards:
0.08 Measured according to AS ISO 354-2006
0.12 0.15 Rated according to AS ISO 11654-20020.280.33 Specimen Area:
0.44 0.45 11.3 m2 (4.76 m x 2.38 m)0.630.75 Mounting:
0.79 0.80 Type E-25
0.830.87 Test Location:
0.87 0.85 Twin Reverberation Rooms0.88 National Acoustic Laboratories
0.86 126 Greville Street, Chatswood NSW
0.83 0.850.84 Instrumentation:
0.78 - Brüel and Kjær Two Channel Pulse Analyser
0.65 0.70 (assembly 2825, 7521, 2 x 3015)
630800
16002000
10001250
25003150
Test 4600D
Sound Absorption Coefficients
4000
Frequency - Hz
SOUND ABSORPTIONTEST CERTIFICATE
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
0.65 0.70 (assembly 2825, 7521, 2 x 3015)
0.63 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600D For and on behalf of Day Design Pty Ltd
Noise Reduction Coefficient, NRC 0.75
Weighted Sound Absorption Coefficient, ααααw 0.75
Thursday, 14 April 2011
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK MEDIUM18 Bradwardine Road, Bathurst, NSW, 2795 55 mm air-space
Parallel - Slotted
ααααs ααααp Australian Standards: 0.18 Measured according to AS ISO 354-20060.20 0.25 Rated according to AS ISO 11654-20020.340.38 Specimen Area:0.46 0.45 11.3 m2 (4.76 m x 2.38 m)0.550.52 Mounting:0.61 0.60 Type E-550.640.66 Test Location:0.65 0.65 Twin Reverberation Rooms0.66 National Acoustic Laboratories0.60 126 Greville Street, Chatswood NSW0.60 0.550.45 Instrumentation:0.41 - Brüel and Kjær Two Channel Pulse Analyser 0.47 0.50 (assembly 2825, 7521, 2 x 3015)
630800
16002000
10001250
25003150
Test 4600E
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
0.47 0.50 (assembly 2825, 7521, 2 x 3015)
0.61 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600E For and on behalf of Day Design Pty Ltd
Noise Reduction Coefficient, NRC 0.55
Weighted Sound Absorption Coefficient, ααααw 0.60
Thursday, 14 April 2011
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK MEDIUM18 Bradwardine Road, Bathurst, NSW, 2795 55 mm air-space
V - Slotted
ααααs ααααp Australian Standards:
0.14 Measured according to AS ISO 354-2006
0.12 0.20 Rated according to AS ISO 11654-20020.270.26 Specimen Area:
0.31 0.30 11.3 m2 (4.76 m x 2.38 m)0.400.42 Mounting:
0.47 0.50 Type E-55
0.560.63 Test Location:
0.70 0.70 Twin Reverberation Rooms0.69 National Acoustic Laboratories
0.64 126 Greville Street, Chatswood NSW
0.57 0.550.50 Instrumentation:
0.53 - Brüel and Kjær Two Channel Pulse Analyser
0.51 0.55 (assembly 2825, 7521, 2 x 3015)
Test 4600F
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
125
400500
100
160
16002000
630800
10001250
25003150
0.51 0.55 (assembly 2825, 7521, 2 x 3015)
0.55 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600F For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
Weighted Sound Absorption Coefficient, ααααw 0.55
Noise Reduction Coefficient, NRC 0.50
5000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK MEDIUM18 Bradwardine Road, Bathurst, NSW, 2795 55 mm air-space
Parallel - SlottedHP50 Insulation
ααααs ααααp Australian Standards: 0.37 Measured according to AS ISO 354-20060.36 0.45 Rated according to AS ISO 11654-20020.590.61 Specimen Area:0.63 0.65 11.3 m2 (4.76 m x 2.38 m)0.700.67 Mounting:0.69 0.70 Type E-550.690.69 Test Location:0.67 0.65 Twin Reverberation Rooms0.64 National Acoustic Laboratories0.61 126 Greville Street, Chatswood NSW0.59 0.550.49 Instrumentation:0.47 - Brüel and Kjær Two Channel Pulse Analyser 0.51 0.55 (assembly 2825, 7521, 2 x 3015)
16002000
630800
10001250
25003150
Test 4600G
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
125
400500
100
160
0.51 0.55 (assembly 2825, 7521, 2 x 3015)
0.64 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600G For and on behalf of Day Design Pty LtdThursday, 14 April 2011
Weighted Sound Absorption Coefficient, ααααw 0.65
Noise Reduction Coefficient, NRC 0.65
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK MEDIUM18 Bradwardine Road, Bathurst, NSW, 2795 55 mm air-space
V - SlottedHP50 Insulation
ααααs ααααp Australian Standards: 0.25 Measured according to AS ISO 354-20060.24 0.35 Rated according to AS ISO 11654-20020.490.53 Specimen Area:0.62 0.65 11.3 m2 (4.76 m x 2.38 m)0.740.84 Mounting:0.95 0.90 Type E-550.980.86 Test Location:0.78 0.80 Twin Reverberation Rooms0.74 National Acoustic Laboratories0.70 126 Greville Street, Chatswood NSW0.63 0.650.61 Instrumentation:0.65 - Brüel and Kjær Two Channel Pulse Analyser 0.61 0.65 (assembly 2825, 7521, 2 x 3015)
Test 4600H
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
125
400500
100
160
16002000
630800
10001250
25003150
0.61 0.65 (assembly 2825, 7521, 2 x 3015)
0.63 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600H For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
Weighted Sound Absorption Coefficient, ααααw 0.75
Noise Reduction Coefficient, NRC 0.75
5000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK MEDIUM18 Bradwardine Road, Bathurst, NSW, 2795 55 mm air-space
V - SlottedHP50 Insulation
ααααs ααααp Australian Standards: 0.25 Measured according to AS ISO 354-20060.24 0.35 Rated according to AS ISO 11654-20020.490.53 Specimen Area:0.62 0.65 11.3 m2 (4.76 m x 2.38 m)0.740.84 Mounting:0.95 0.90 Type E-550.980.86 Test Location:0.78 0.80 Twin Reverberation Rooms0.74 National Acoustic Laboratories0.70 126 Greville Street, Chatswood NSW0.63 0.650.61 Instrumentation:0.65 - Brüel and Kjær Two Channel Pulse Analyser 0.61 0.65 (assembly 2825, 7521, 2 x 3015)
Test 4600H
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
125
400500
100
160
16002000
630800
10001250
25003150
0.61 0.65 (assembly 2825, 7521, 2 x 3015)
0.63 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600H For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
Weighted Sound Absorption Coefficient, ααααw 0.75
Noise Reduction Coefficient, NRC 0.75
5000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK HIGH18 Bradwardine Road, Bathurst, NSW, 2795 98 mm air-space
Parallel - Slotted
ααααs ααααp Australian Standards: 0.47 Measured according to AS ISO 354-20060.41 0.50 Rated according to AS ISO 11654-20020.590.61 Specimen Area:0.63 0.60 11.3 m2 (4.76 m x 2.38 m)0.620.64 Mounting:0.70 0.65 Type E-1000.670.63 Test Location:0.62 0.60 Twin Reverberation Rooms0.61 National Acoustic Laboratories0.53 126 Greville Street, Chatswood NSW0.50 0.500.48 Instrumentation:0.43 - Brüel and Kjær Two Channel Pulse Analyser 0.49 0.50 (assembly 2825, 7521, 2 x 3015)
Test 4600I
Sound Absorption CoefficientsFrequency - Hz
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
SOUND ABSORPTIONTEST CERTIFICATE
100
160
10001250
2500
125
400500
200250315
16002000
630800
40003150
0.49 0.50 (assembly 2825, 7521, 2 x 3015)
0.62 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600I For and on behalf of Day Design Pty LtdThursday, 14 April 2011
40005000
Weighted Sound Absorption Coefficient, ααααw 0.60
Noise Reduction Coefficient, NRC 0.60
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK HIGH18 Bradwardine Road, Bathurst, NSW, 2795 98 mm air-space
V - Slotted
ααααs ααααp Australian Standards:
0.29 Measured according to AS ISO 354-2006
0.26 0.35 Rated according to AS ISO 11654-20020.470.51 Specimen Area:
0.60 0.60 11.3 m2 (4.76 m x 2.38 m)0.680.64 Mounting:
0.70 0.65 Type E-100
0.580.57 Test Location:
0.59 0.60 Twin Reverberation Rooms0.57 National Acoustic Laboratories
0.50 126 Greville Street, Chatswood NSW
0.47 0.500.55 Instrumentation:
0.57 - Brüel and Kjær Two Channel Pulse Analyser
0.51 0.55 (assembly 2825, 7521, 2 x 3015)
630800
16002000
10001250
25003150
Test 4600J
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
0.51 0.55 (assembly 2825, 7521, 2 x 3015)
0.59 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600J For and on behalf of Day Design Pty Ltd
Noise Reduction Coefficient, NRC 0.60
Weighted Sound Absorption Coefficient, ααααw 0.60
Thursday, 14 April 2011
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK HIGH18 Bradwardine Road, Bathurst, NSW, 2795 98 mm air-space
Parallel - SlottedHP50 Insulation
ααααs ααααp Australian Standards:
0.54 Measured according to AS ISO 354-2006
0.47 0.60 Rated according to AS ISO 11654-20020.720.66 Specimen Area:
0.67 0.65 11.3 m2 (4.76 m x 2.38 m)0.690.67 Mounting:
0.69 0.70 Type E-100
0.700.66 Test Location:
0.64 0.65 Twin Reverberation Rooms0.61 National Acoustic Laboratories
0.55 126 Greville Street, Chatswood NSW
0.54 0.550.50 Instrumentation:
0.47 - Brüel and Kjær Two Channel Pulse Analyser
0.54 0.55 (assembly 2825, 7521, 2 x 3015)
Test 4600K
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
16002000
10001250
25003150
630800
0.54 0.55 (assembly 2825, 7521, 2 x 3015)
0.67 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600K For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
5000
Noise Reduction Coefficient, NRC 0.65
Weighted Sound Absorption Coefficient, ααααw 0.65
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK HIGH18 Bradwardine Road, Bathurst, NSW, 2795 98 mm air-space
Parallel - SlottedHP50 Insulation
ααααs ααααp Australian Standards:
0.54 Measured according to AS ISO 354-2006
0.47 0.60 Rated according to AS ISO 11654-20020.720.66 Specimen Area:
0.67 0.65 11.3 m2 (4.76 m x 2.38 m)0.690.67 Mounting:
0.69 0.70 Type E-100
0.700.66 Test Location:
0.64 0.65 Twin Reverberation Rooms0.61 National Acoustic Laboratories
0.55 126 Greville Street, Chatswood NSW
0.54 0.550.50 Instrumentation:
0.47 - Brüel and Kjær Two Channel Pulse Analyser
0.54 0.55 (assembly 2825, 7521, 2 x 3015)
Test 4600K
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
16002000
10001250
25003150
630800
0.54 0.55 (assembly 2825, 7521, 2 x 3015)
0.67 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600K For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
5000
Noise Reduction Coefficient, NRC 0.65
Weighted Sound Absorption Coefficient, ααααw 0.65
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK HIGH18 Bradwardine Road, Bathurst, NSW, 2795 98 mm air-space
V - SlottedHP50 Insulation
ααααs ααααp Australian Standards:
0.38 Measured according to AS ISO 354-2006
0.35 0.45 Rated according to AS ISO 11654-20020.590.68 Specimen Area:
0.79 0.80 11.3 m2 (4.76 m x 2.38 m)0.870.93 Mounting:
0.96 0.90 Type E-100
0.870.69 Test Location:
0.65 0.65 Twin Reverberation Rooms0.62 National Acoustic Laboratories
0.63 126 Greville Street, Chatswood NSW
0.65 0.650.67 Instrumentation:
0.66 - Brüel and Kjær Two Channel Pulse Analyser
0.62 0.65 (assembly 2825, 7521, 2 x 3015)
Test 4600L
Sound Absorption Coefficients
SOUND ABSORPTIONTEST CERTIFICATE
4000
Frequency - Hz
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
16002000
10001250
25003150
630800
0.62 0.65 (assembly 2825, 7521, 2 x 3015)
0.63 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600L For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
5000
Noise Reduction Coefficient, NRC 0.75
Weighted Sound Absorption Coefficient, ααααw 0.70 (L)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK SAWTOOTH18 Bradwardine Road, Bathurst, NSW, 2795 60 mm to 200 mm air-space
Parallel - Slotted
ααααs ααααp Australian Standards:
0.47 Measured according to AS ISO 354-2006
0.50 0.50 Rated according to AS ISO 11654-20020.600.53 Specimen Area:
0.62 0.60 11.3 m2 (4.76 m x 2.38 m)0.620.65 Mounting:
0.63 0.65 Type E-60 to 200
0.640.65 Test Location:
0.60 0.60 Twin Reverberation Rooms0.60 National Acoustic Laboratories
0.53 126 Greville Street, Chatswood NSW
0.53 0.500.50 Instrumentation:
0.48 - Brüel and Kjær Two Channel Pulse Analyser
0.53 0.55 (assembly 2825, 7521, 2 x 3015)
630800
16002000
10001250
25003150
Test 4600M
Sound Absorption Coefficients
4000
Frequency - Hz
SOUND ABSORPTIONTEST CERTIFICATE
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
100
160125
400500
0.53 0.55 (assembly 2825, 7521, 2 x 3015)
0.69 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600M For and on behalf of Day Design Pty Ltd
Noise Reduction Coefficient, NRC 0.60
Weighted Sound Absorption Coefficient, ααααw 0.60
Thursday, 14 April 2011
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK SAWTOOTH18 Bradwardine Road, Bathurst, NSW, 2795 60 mm to 200 mm air-space
V - Slotted
αs αp Australian Standards: 0.36 Measured according to AS ISO 354-20060.42 0.45 Rated according to AS ISO 11654-20020.570.56 Specimen Area:0.64 0.65 11.3 m2 (4.76 m x 2.38 m)0.700.71 Mounting:0.72 0.65 Type E-60 to 2000.550.54 Test Location:0.55 0.55 Twin Reverberation Rooms0.57 National Acoustic Laboratories0.57 126 Greville Street, Chatswood NSW0.56 0.550.57 Instrumentation:0.61 - Brüel and Kjær Two Channel Pulse Analyser 0 59 0 60 ( bl 2825 7521 2 3015)
630800
16002000
10001250
25003150
Test 4600N
Sound Absorption Coefficients
4000
Frequency - Hz
200250315
SOUND ABSORPTIONTEST CERTIFICATE
D A Y D E S I G N
100
160125
400500
0.59 0.60 (assembly 2825, 7521, 2 x 3015)
0.65 - Brüel and Kjær Cathode Follower type 2660- Brüel and Kjær Microphone type 4179- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600N For and on behalf of Day Design Pty Ltd
Noise Reduction Coefficient, NRC 0.60
Weighted Sound Absorption Coefficient, αw 0.60 (L)
Thursday, 14 April 2011
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Soun
d Ab
sorp
tion
Coe
ffici
ent
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK SAWTOOTH18 Bradwardine Road, Bathurst, NSW, 2795 60 mm to 200 mm air-space
Parallel-SlottedHP50 Insulation
αs αp Australian Standards: 0.51 Measured according to AS ISO 354-20060.48 0.55 Rated according to AS ISO 11654-20020.670.58 Specimen Area:0.65 0.65 11.3 m2 (4.76 m x 2.38 m)0.690.71 Mounting:0.70 0.70 Type E-60 to 2000.640.65 Test Location:0.60 0.60 Twin Reverberation Rooms0.59 National Acoustic Laboratories0.56 126 Greville Street, Chatswood NSW0.59 0.550.53 Instrumentation:0.54 - Brüel and Kjær Two Channel Pulse Analyser 0 57 0 60 ( bl 2825 7521 2 3015)
630800
16002000
10001250
25003150
Test 4600O
Sound Absorption Coefficients
4000
Frequency - Hz
SOUND ABSORPTIONTEST CERTIFICATE
200250315
D A Y D E S I G N
100
160125
400500
0.57 0.60 (assembly 2825, 7521, 2 x 3015)
0.71 - Brüel and Kjær Cathode Follower type 2660- Brüel and Kjær Microphone type 4179- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600O For and on behalf of Day Design Pty Ltd
Noise Reduction Coefficient, NRC 0.65
Weighted Sound Absorption Coefficient, αw 0.60 (L)
Thursday, 14 April 2011
50004000
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Soun
d Ab
sorp
tion
Coe
ffici
ent
Frequency - Hz
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK SAWTOOTH18 Bradwardine Road, Bathurst, NSW, 2795 60 mm to 200 mm air-space
V - SlottedHP50 Insulation
ααααs ααααp Australian Standards:
0.50 Measured according to AS ISO 354-2006
0.51 0.60 Rated according to AS ISO 11654-20020.750.80 Specimen Area:
0.85 0.85 11.3 m2 (4.76 m x 2.38 m)0.961.01 Mounting:
0.95 0.90 Type E-60 to 200
0.760.64 Test Location:
0.63 0.65 Twin Reverberation Rooms0.65 National Acoustic Laboratories
0.67 126 Greville Street, Chatswood NSW
0.67 0.650.69 Instrumentation:
0.70 - Brüel and Kjær Two Channel Pulse Analyser
0.66 0.70 (assembly 2825, 7521, 2 x 3015)
Test 4600P
Sound Absorption Coefficients
4000
Frequency - Hz
SOUND ABSORPTIONTEST CERTIFICATE
200250315
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
125
400500
100
160
16002000
630800
10001250
25003150
0.66 0.70 (assembly 2825, 7521, 2 x 3015)
0.70 - Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
Project Number: 4600P For and on behalf of Day Design Pty Ltd
4000
Thursday, 14 April 2011
Weighted Sound Absorption Coefficient, ααααw 0.70 (L)
Noise Reduction Coefficient, NRC 0.75
5000
0.00
0.20
0.40
0.60
0.80
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK Float18 Bradwardine Road, Bathurst, NSW, 2795 415 mm air-space
Parallel - SlottedHP50 Insulation
ααααs ααααp Australian Standards: 0.23 Measured according to AS ISO 354-20060.34 0.40 Rated according to AS ISO 11654-20020.580.60 Specimen Area:0.72 0.70 Panel Test Area 8.5 m2 + Floor 3.1 m2
0.76 Total Test Area 11.6 m2
0.760.79 0.80 Mounting:0.81 Type G - 400
0.820.86 0.85 Test Location:0.83 Twin Reverberation Rooms0.83 National Acoustic Laboratories
0.79 0.80 126 Greville Street, Chatswood NSW
0.750.71 Instrumentation:
SOUND ABSORPTIONTEST CERTIFICATE
10001250
2500
D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
16002000
630800
125100
Frequency - Hz
Test 4600Q
Sound Absorption Coefficients
250
160200
315
3150
400500
0.71 Instrumentation:0.79 0.80 - Brüel and Kjær Two Channel Pulse Analyser
0.92 (assembly 2825, 7521, 2 x 3015)
- Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer Phillip Lu, BSc (Physics)
4000
Noise Reduction Coefficient, NRC 0.80
Thursday, 14 April 2011
5000
Weighted Sound Absorption Coefficient, ααααw 0.85
3150
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Project Number: 4600Q For and on behalf of Day Design Pty Ltd
Manufacturer: Test Specimen:
Supawood Architectural Lining Systems NCK Float18 Bradwardine Road, Bathurst, NSW, 2795 415 mm air-space
V - SlottedHP50 Insulation
ααααs ααααp Australian Standards: 0.23 Measured according to AS ISO 354-20060.31 0.35 Rated according to AS ISO 11654-20020.550.71 Specimen Area:0.80 0.80 Panel Test Area 8.5 m2 + Floor 3.1 m2
0.85 Total Test Area 11.6 m2
0.770.72 0.75 Mounting:0.80 Type G - 4000.810.86 0.85 Test Location:0.88 Twin Reverberation Rooms0.84 National Acoustic Laboratories0.87 0.85 126 Greville Street, Chatswood NSW0.830.86 Instrumentation:
Sound Absorption Coefficients
250
160200
315400500
10001250
2500
Test 4600RSOUND ABSORPTION
TEST CERTIFICATE D A Y D A Y D A Y D A Y
D E S I G N D E S I G N D E S I G N D E S I G N
16002000
630800
125100
Frequency - Hz
3150 0.86 Instrumentation:0.86 0.85 - Brüel and Kjær Two Channel Pulse Analyser 0.90 (assembly 2825, 7521, 2 x 3015)
- Brüel and Kjær Cathode Follower type 2660
- Brüel and Kjær Microphone type 4179
- Brüel and Kjær Sound Level Calibrator type 4231- Yamaha Professional Sound Sources type S500
..................................................................Date of Test: Test Officer: Phillip Lu, BSc (Physics)
5000
Weighted Sound Absorption Coefficient, ααααw 0.85
Thursday, 14 April 2011
Noise Reduction Coefficient, NRC 0.80
40003150
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
So
un
d A
bso
rpti
on
Co
effi
cien
t
Frequency - Hz
Sound Absorption Coefficients Reference Curve
Date of Test: Test Officer: Phillip Lu, BSc (Physics)Project Number: 4600R For and on behalf of Day Design Pty Ltd
D A Y D E S I G N
METHOD OF CALCULATION OF SOUND ABSORPTION COEFFICIENTS
APPENDIX A4600
The absorption coefficient is calculated from the change in reverberation time between the empty room and the room with the test specimen. Calculations have been carried out in accordance with the Australian Standard AS ISO 354-2006: “Acoustics – Measurement of sound absorption in a reverberation room” in conjunction with Australian Standard AS ISO 11654-2002: -“Acoustics Rating of sound absorption – Materials and systems”, as outlined below: The equivalent sound absorption area, AT of the test specimen, in square metres, is calculated using the following formula:
TA = 12 AA −
= )(4113.55 211122
mmVTcTc
V −×−⎟⎟⎠
⎞⎜⎜⎝
⎛−×
Where = Equivalent sound absorption area of only the test specimen (m2) TA
1A = The equivalent sound absorption area of the empty reverberation Room (m2)
= The equivalent sound absorption area of the reverberation room including the test specimen (m2)
2A
V = Room volume (m3)
= propagation of sound in air at temperature T1 ie. C1 = (331 + 0.6 × T1) in (m/sec) for temperatures in the range of 15 oC to 30 oC
1C
= propagation of sound in air at temperature T2 ie. C2 = (331 + 0.6 × T2) in (m/sec) for temperatures in the range of 15 oC to 30 oC
2C
21, mm = The power attenuation coefficient, in reciprocal metres calculated according to ISO 9613-1 using climatic conditions that have been present in the empty reverberation room and the reverberation room with the test specimen respectively, during the measurement. The value of m can be calculated from the attenuation coefficient, α (not the absorption coefficient) which is used according to the formula:
10Log(e)
α=m
The sound absorption coefficient of the test specimen, αs, in square metres, is calculated using the following formula:
SAT
s =α
Where sα = The sound absorption coefficient
TA = Equivalent sound absorption area of only the test specimen (m2)
= the area, in square metres, covered by the test specimen S