Technical SpecificationsUnit: PEX 240 DW
1 Total Cooling Capacity- kW
2 Sensible Cooling Capacity – kW
3 Tonnage4 Total Cooling Capacity at 22 Deg C inside (kW)
5 Sensible cooling Capacity
6 Tonnage (at 20 Deg C)
7 Total Cooling Capacity at 20 Deg c inside (kW)
8 Sensible cooling Capacity
9 Tonnage (at 20 Deg C)
Manufacturer
b. Country of Origin
c. Unit Model No.
d. Total Electrical power requirement
i. Compressor (KW)
ii. Condenser fan/s (KW)
iii. Blower (KW)
iv. Heaters (KW)
v. Humidifier (KW)
Compressor
a. Country of origin
b. Manufacturer
c. Type of compressor
d. Number of Compressors
e. Model No.
a.
f. Nominal capacity
h.
i. Actual capacity at 20 Deg C/50%
j. BHP consumption
k. Total input current per compressor per phase
l. Type of refrigerant
m. Operating Speed
n. Safety controls
HP cutout (manual reset)
LP cutout (auto reset)
o. Protections
p. Operating voltage
q. Type of vibration isolators
Air-cooled Condenser
a. Country of origin
b. Manufacturer
c. Model No.
d. Face Area (SqM)
e. Number of rows
g.
Suction temperature
Discharge temperature
f. Fins material
g. Type of fins
h. No. of fins per inch
i. Air flow (Cfm)
j. Air velocity across coil (FPM)
k. Pressure drop (Ft of water)
l. Tube material
m. Tube dia (mm)
n. Tube thickness (mm)
o. Water side tube surface area
p. Refrigerant side tube surface area
q. No. of fans
r. Dia. of each fan
s. Motor rating (KW)
t. Motor protection
u. Motor full load current
v. Overall dimensions
Cooling Coil
a. Manufacturer
b. Tube dia and thickness (mm)
c. Tube material
d. Fin material
e. Bonding of fins
f. Fin Spacing
Coil face velocity (MPM/FPM)
h. Coil face area (SqM/Sft)
Fan & Fan motor
a. Manufacturer
b. Type of fan
c. Number of fans
d. Length & dia of blower
e. Air quantity in Cfm
Outlet velocity (MPM)
g. Motor rating per motor
h. Type of motor
g.
f.
i. Rated speed
j. Electrical characteristics
a. Manufacturer
b. Type
c. Capacity (Kg/Hr)
d. Input Current
e. Operating voltage
f. Cleaning action
g. Water supply pressure range (kPa)
h. Drain connection (mm)
i. Connection supply (BSP Female)
Electrical Strip Heater
a. Manufacturer
b. Type
c. Quantity
d. Material of sheath
e. Material of fins
f. Power rating (KW)
Humidifier
g.
h. Type of protections
Filters
a. Manufacturer
b. Type
c. Numbers of filters
d. Size (mm)
e. Material
f. Efficiency
a. Standard protections
b.
Refrigerant Piping
a. Material for pipes
b. Pipe wall thickness (mm)
Surface temperature of the element when tested in still air at 20 deg C ambient
Cont
Switchgear
c. Material of fittings
d. Material of valves
e. Make of valves
f. Make of refrigerant float if any
g. Pressure gauges
i. Make
ii. Range
Unit Construction
a. Cabinet Material
b. Surface Finish
c. Color and Shade
d. Paint Thickness
e. Cabinet Insulation Thickness (mm)
f. Insulation Material
g. Density
Unit capacity (Actual)
a. Total Capacity (TR)
b. Sensible Capacity (TR)
c. Sensible Heat Ratio
Physical Sizes
a. Overall dimensions (mm)
b. Services Clearances (mm)
c. Operating Weight (Kg.)
d. Type of Vibration Isolator
Technical Specifications PEX 240 DW
39.4
38.4
11.237.5
37.2
10.7
35.6
36
10.1
Emerson Network Power India
India
PeX 240 DW
8.84
3.08
4.4
9
3.8
Compressor
USA
Copeland
Scroll
2 No.
ZR – 68KC
5.6 TR
9 Deg C
56 Deg C
NA
NA
20 Amps
R-22
2900RPM
Yes
Yes
O/L, HP, LP, Phase Reversal
415 ± 10% V
Rubber Grommet
Air-cooled Condenser
India
Emerson Network
LS - 40
1.75 SqM
2
Aluminum
Louvered fins
12
7200 CFM
NA
NA
Copper
9.525mm
0.3mm
NA
10.78
2 No./Cond.
500mm
0.77 X 2 Nos.
MCB
6.8 Amps
1418 (L) X 980 (H) X 985 (D)
Cooling Coil
Emerson Network Power
3/8” & 29G
Copper
Aluminum
Hydraulically Mechnaical Bonding
14FPI
141 MPM
0.95 Sqmt.
Fan & Fan motor
Emerson Network Power
Forward Curved Centrifugal Fan D/DW
1
12” X 12” / EACH
9330
NA
2.2kW
Squirrel Cage Induction
1400RPM
400/3/50
Emerson Network Power
Immersed Electrode Steam Generation
5
3.8
230V
Self Flush Cycle
100-700
2”
Electrical Strip Heater
Emerson Network Power
Finned Tubular
2
Nickel Plated Steel
Aluminum
9.0kW
½”
NA
O/I Relay / Tempearture Protection
Filters
Emerson Network Power
HDPE
2
790 X 790 X 100
Dry Media / Disposable
95% Down TO 5 μ
CEMS 100
Built-in single phasing preventor.
Built-in under voltage cut out.
Built-in thermal over load for compressor.
Unit main disconnect isolator.
Compressor circuit breaker & contactor.
Main fan circuit breaker & contactor.
Humidifier circuit breaker & contactor.
Heater circuit breaker & contactor.
Condenser fan circuit breaker.
Control power circuit breaker.
Refrigerant Piping
Copper
NA
Wood
Brass
Danfoss
NA
NA
-
-
Unit Construction
CRAC Powder Coated
Powder Coated
APO Grey
1.6mm
1”
Fibre Glass Covered With Acoustic Material
48kg/M3
Unit capacity (Actual)
11.2
10.9
0.975
Physical Sizes
1700 X 850 X 1950
800mm (FRONT)
512