Service Manual Split System Air Conditioner Model: DSB-F074LH DAEWOO ELECTRONICS CO., LTD. Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information,please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).

Daewo-Dsb f074lh

Embed Size (px)

DESCRIPTION

manual de aire acondicionado

Citation preview

  • Service Manual

    Split System AirConditioner

    Model: DSB-F074LH

    DAEWOO ELECTRONICS CO., LTD.

    Caution: In this Manual, some parts can be changed for improving,their performance without notice in the parts list. So, if youneed the latest parts information,please refer to PPL(PartsPrice List) in Service Information Center (http://svc.dwe.co.kr).

  • 21. SPECIFICATIONS

    MODEL DSB-F074LHITEM

    Function Cooling & Heating

    Class T1

    Power AC 220~240V/ 50Hz

    Capacity W 2,050

    Btu/h 7,000

    Dehumidification l/h 1.0

    Running Current A 3.1/3.3

    Power Input W 680/720

    Type Rotary

    Model G4C072JU1ER (Samsung)Capacitor 30F / 450VAC

    Division Indoor Unit Outdoor Unit

    Type Cross flow fan Propeller fan

    Capacitor 1.0F 400VAC 1.8F 400VAC

    Motor Model Number YDK-8-4B YDK-30-68

    Sound Level (Hi) dB(A) 39 48Fan Speed (Hi) RPM 1,350 850

    Control Capillary

    Charge Q'ty g 730

    Type Flare

    OD (Liquid/Gas) in(mm) 1/4 (6.35) 3/8 (9.52)Dimensions (W x H x D) mm 750 x 245 x 179 654 x 549 x 256Net Weight kg 7.0 34

    Electrical Data

    Compressor

    FanMotor

    Refrigerant(R-410A)

    Connection

  • 32. OUTLINE AND DIMENSIONS

    1 INDOOR UNIT

    750

    Plate Mounting

    REM

    OCO

    N

    Connecting Pipe

    Grille Insert

    179

    245

    REM

    OTE CO

    NTROLLER

    Frame G

    rilleBody

    Plate Mounting

    DSB-F074LH

  • 12

    Indoor Unit

    DSB-183LH/183LH-R/240LH-R, DSA-183LH-R/240LH-R

    DSB-182LH

    DSB-123LH/093LH

    DSB-070LH/071LH/091LH/092LH

    Indoor Unit

    Indoor Unit

    Indoor Unit

    Installation Plate

    Wall Hole (65)

    Wall Hole (65)

    Wall Hole (65)

    Wall Hole (65)

    Installation Plate

    Installation Plate

    Installation Plate

    90

    40

    97

    53

    184

    50 325 235 140

    35

    355 285 122

    40

    121 385 385 121

    40

    4017

    80 460 400 140

    50

    INSTALLING THE INSTALLATION PLATE

    Unit : mm DSB-F184, 244 LH/PH/AH

    DSB-F154LH/PH/AH

    DSB-F094, 124 LH/PH/AH

    INSTALLING THE INSTALLATION PLATE. DSB-F074LH

  • 5DSB-F074LH

    Outlet

    Foot Cushion

    Cabinet Front

    Cabinet SideP

    anel TopGuide Support

    SVC Cover

    Servise Valve

    Inlet

    Outlet

    Inlet

    2 OUTDOOR UNIT

  • DSB-F074LH

    6

    1 NAME AND FUNCTION OF PARTS

    Indoor Unit

    3. OPERATION

    Fan Direction(Up/Down)

    Connection CoverRemove cover to accessthe AC connection fromthis unit to the outdoor unit.

    Sensor Wire

    02 Hose Cover (AH Model Only)

    Electrostatic FilterRemoves dust particles from the air.

    IndicatorsIndicate the setting

    Indoor Cover

    Power Plug

    RemoteSensor

    LCD Remote Controller

    Deodorizing FilterRemoves bad smellsfrom the air.

    Cold Air

    Air In

    Nano Silver FiltersRemoves dust and

    prohibits germs.

    Electric Dust Collector(Air clean Plasma)Removes small dust andgenerates (-) ions.(PH/AH Model Only)

  • 7DSB-F074LH

    Connection CoverRemove cover to access the AC connectionto the indoor unit.

    Service ValvesThe indoor and outdoor unitsare connected by copper tubeswhich are connected here.

    AIR IN

    AIR OUT

    Connection WireO2 Hose Wire(AH Models Only)

    Connection Pipes

    Drain Hose

    Outdoor Unit

  • 8Name of Each Button

    2 REMOTE CONTROLLER

    DSB-F074LH

    MODE

    SLEEP

    ON/OFF

    TIMER

    ENTER/ CANCEL

    FAN SPEED

    TURBO/MILD

    DisplayDisplay information

    TIMER ENTER/CANCEL ButtonPress to enter a timer setting or to cancel timer setting

    TIMER ON/OFF ButtonPress to set the unit off or on time.(0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)

    MODE ButtonPress to cycle through the modes(Auto/Quick/Cool/Fan/Dehumidifier/Heat)SLEEP ButtonPress to set the unit for the sleep mode.

    FAN DIR. ButtonPress to select up/downdirection for fan.

    ON/OFF ButtonPress to turn the uniton or off.TEMPERATURE ButtonsPress to raise or lower the desired temperature.

    FAN SPEED ButtonPress to select the fan speed (High " ", Middle " ", Low " ", Natural).

    COVERSlide down to access mostof the remote buttons.Slide down further toaccess the batterycompartment.

    AUTO

    FAN DIR.

    TURBO/MILDPress to select super poweroperation (Turbo) mode.

    MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)Light to indicate the mode selected.

    TIMER Indicators (Include sleep)Light to indicate the timer function mode.

    TEMPERATURE & RESERVATION TIME lndicatorsLight to indicate the temperature or time.

    FAN DIRECTION IndicatorsLight to indicate thefan direction.

    NATURAL IndicatorLight to indicate thespeeds simulating a breeze.

    FAN IndicatorsLight to indicate the fan speed.

    AUTO

  • 9If you set time in OFF-Timer Mode, the unit will stop at the set time.

    If you set time in ON-Timer Mode, the unit will run at the set time.

    (1) Range of setting temperature: 18~32C(2) Setting temperature: Operating temperature of compressor

    (3) During the time of test operating, Fan (Indoor, Outdoor) and Compressor is running regardless of roomtemperature.

    If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep " or "beep,beep".(1) In the case of receiving ON/OFF signal-"beep" "beep"(2) And so on-"beep"

    OFF-Timer

    3 DESCRIPTION OF FUNCTIONS

    Unit ON

    Unit OFF

    SET Time HOUR

    ON

    OFF

    ON-Timer

    Unit ON

    Unit OFF

    SET Time HOUR

    ON

    OFF

    Control of Room Temperature

    Buzzer

    COMP (ON)

    *RT: ROOM TEMPERATURE DT: DESIRED TEMPERATURE

    COMP (OFF)

    -1C 0C(COOLING)

    (RT-DT)

    COMP (OFF)

    COMP (ON)

    -1C 0CHEATING

    (RT-DT)+1C +1C

  • 10

    Fan Speed (Indoor Unit)

    (1) Motor speed (high speed, middle speed, low speed).(2) Remote controller setting fan speed. (Auto, L, M, H, Natural)(3) Relation of operating mode between fan speed.

    (4) Automatic OperationIf the unit is set in 'AUTO' mode, the unit operates automatically according to the room temperature to keep theroom temperature comfortable.

    0C

    L

    M

    H

    1C 2C (R.T-D.T)

    0C

    L

    M

    H

    1C 2C (DT-RT)

    (COOLING)

    (HEATING)

    FAN ONLY COOL DEHUMI- AUTO QUICK HEATDIFICATION

    H H H L H H H

    M M M L M H M

    L L L L L H L

    Auto X Auto L Auto H Auto

    Natural Natural Natural L Natural H Natural

  • 11

    (1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can beused to run the unit.

    (2) The setting conditions of Emergency operation are as follows. Operation mode: Quick Preset temperature:18C: Cooling, 32C: Heating) Fan speed: High* You cannot operate with remote controller.

    (1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature. (The unit will not operate after 4 hour)

    (2) For changing the temperature.

    (3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEPindicator will disappear in the display.

    Sleep Mode

    Indoor Fan Motor RPM for each Models

    Emergency Operation

    0 0.5 1.0 HOUR(COOLING CYCLE)

    DT

    +0.5C+0.5C

    +0.5C

    0 0.5 1.0 HOUR(HEATING CYCLE)

    DT

    0.5C0.5C

    0.5C

    MODEL

    F074

    F094

    F124

    F154

    F184

    F244

    MODECOOLHEATCOOLHEATCOOLHEATCOOLHEATCOOLHEATCOOLHEAT

    Turbo1360

    1280

    1290

    1390

    1280

    1280

    High135012301250112012601300138013501260115012601260

    Mid129011201150102011501220132012601170105011701170

    Low106010609909709701070102010901020100010201020

    Ultra low910820840800840910940910900870900900

    Monitoring

    500

    500

    500

    500

    500

    500

  • 12

    Frost Prevention of Indoor Unit

    When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coiltemperature is lower than 0C at the end of 10 minutes of continuous compressor operation from the start, themicrocomputer of the unit stops the compressor to protect the unit from the frost. The control procedure forindoor coil freeze protection.

    1) The compressor and outdoor fan turn off.2) Indoor fan operates according to user set speed.3) The normal operation returns when the indoor coil

    temperature is higher than 7C or equal to 7C.

    -1C +7C

    Compressor and Outdoor Fan ON ON

    OFF

    Indoor FanSet speed

    (Indoor coil temperature)

    Auto Mode(1) In Auto Mode

    After the indoor fan is operated for 20 seconds in the Auto Mode the unit will operate automatically by selectingoperating Mode according to the room temperature

    (2) Selecting Operating Mode AgainRoom temperature meets desired temperature and the compressor stops running over 30 minutes, then the unitselects operating Mode again.

    3 min. Time Delay of Compressor

    In normal operation, there is a time delay of three minutes between turn off and turning back on including initialpower up.

    ROOM TEMPERATURE

    DT-2C RT

    DT-2C RT DT+3CDT+3C RT

    OPERATING MODE

    Heating

    Dehumidifier

    Cooling

    FLAP POSITION

    Heating Position

    Cooling Position

    Cooling Position

    (RT: Room temperature)

    >

  • 13

    1) Cooling Mode* When the room temperature is higher than 22C1Fan Speed: Super high speed2Air discharge direction: Fixed3Set temperature: 18C (Fixed)4Compressor and Outdoor Fan

    The air discharge direction procedure is belowFixed Up/Down Up/Down Fixed

    * The option is LEFT/RIGHT direction.

    1) Heating Mode* When the room temperature is higher than 22C1Fan Speed: Super high speed2Air discharge direction: Fixed3Set temperature: 18C (Fixed)4Compressor and Outdoor Fan

    The air discharge direction procedure is belowFixed Up/Down Up/Down Fixed

    * The option is LEFT/RIGHT direction.

    Dehumidification Mode

    Air Discharge Direction(only remocon operation)

    Quick Mode(Powerful Cooling & Heating)

    The air discharge direction procedure is below. Fixed Up/Down Fixed

    Up/Down

    1Desired temperature < Room temperatureOutdoor Fan, Compressor : ONIndoor Fan : Low speed

    2Desired temperature Room temperatureCompressor : 3 min/ON, 5 min/OFFFan Speed : low speed

    3Room temperature 18CCompressor : OFFFan speed : Low speed

    COOLING POSITION

    HEATING POSITION

  • 14

    Defrost Function Chart for Outdoor Condenser

    Max Load Heating Operation Diagram

    Note1 : 120sec for 24kBtu Model Note2 : The Temperature is over 120C or 15 minute later.

    Note1 : 30s ON. 120s OFF when the Compressor is OFF. Note2 : The Fan is ON when the temperature is below 49C. Note3 : The Temperature is over 60C and 1 minute later.

    Comp

    Start

    4 Way

    OD Fan

    ID Fan40sec*Note1

    15min*Note2

    6sec 6sec40sec

    Return

    60C

    Temperature (Indoor Evaporator)

    57C

    49C

    38C

    ID FAN* Note1

    Monitoring"Ultra Low"

    Set Value"Hi, Mid, Low" "Hi" "Hi"

    OD FAN OFF *Note2

    OFF *Note3COMP

  • 15

    Self-Diagnostic Function

    The control will contain diagnostic test to verify the integrity of the system.

    (1)Error Code Display Pattern1ON LAMP: Blink

    Self Diagnostic Function Description

    1. Sensor ErrorOpen or Short circuit of Sensors, Room, Indoor Coil Sensor and Outdoor Coil SensorOpen : Micom, Input Voltage 0~0.3V, Short: Micom, Input Voltage 4.7~5.0V

    2. Compressor ErrorAt the start operation, the Compressor is ON and 5 Minutes later, the Temperature change value of IndoorCoil is below +/-2C. Emergency Mode Operation detect only

    3. 4 Way Valve ErrorAt the start operation, the Compressor is ON and then.Indoor Coil Temperature goes up to 2C in Cooling Operation ModeIndoor Coil Temperature goes down to 2C in Heation Operation Mode

    LED BLINK PATTERN CASE NOTE

    Room Sensor open or Short Continuously woorking to fix room temperature 18C in cooling mode.

    Continuously woorking to fix roomtemperature 32C in heating mode

    I/D coil sensor open or short Do not woorking

    1 times blink O/D coil sensor open or short

    Compressor or electrical parts Continuously workiugof compressor error.

    2 times blink Gas leak

    0.5s

    8s

  • 40

    4. WIRING DIAGRAM

    Indoor Unit

    Indoor Unit

    DSB-F094, 124LH DSB-F094, 124PH

  • 43

    Outdoor Unit

    Outdoor Unit DSB-F074LH

    DSB-F094, 124AH DSB-F154, 184 LH/PH

    DSB-F154, 184AH DSB-F244LH/PH

  • 5. REFRIGERANT CYCLE

    18

    Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.

    [Heat Pump Mode]

  • 19

    2 Table of Suction Pressures according to thechange of Outdoor Room Temp.

    MODEL

    DSB-F074 LH/AH

    DSB-F094LH/PH/AH

    DSB-F124LH/PH/AH

    DSB-F154LH/PH/AH

    DSB-F184LH/PH/AH

    DSB-F244LH/PH/AH

    REFRIGERANT

    730g

    900g

    1,000g

    1,150g

    1,200g

    1,750g

    INDOOR ROOMTEMP.(DB/WB, C)

    27.0/19.0

    27.0/19.0

    27.0/19.0

    27.0/19.0

    27.0/19.0

    27.0/19.0

    OUTDOOR ROOMTEMP.(DB/WB, C)

    25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 /

    Bar (gage)8.38.79.19.29.78.58.99.39.49.97.68.08.48.69.08.08.48.89.09.47.68.08.48.69.07.68.08.48.69.0

    kPa, (gage)830870912925970850890932945990760800843860900800840883900940760800840860900760800840860900

    SUCTION PRESSURE

    NOTE)1) These experiments are processed on the condition of the fixed indoor room TEMP.( DB: 27.0C, WB: 19.0C)2) It takes at least ten minutes for the change of suction pressure to be steady-state, after Air conditioner operates3) To analyze accurately whether refrigerant of Air conditioner leaks or not, you have to check not only suction

    pressure but also discharge and suction temperature of compressor4) These data can be changed slightly according to the temperature of environment or each set(Air conditioner)

  • 20

    3 R410A & R22 SATURATION PRESSURE TABLER410A R22

    Temp (C) PRESSURE(LIQUID): bar PRESSURE(VAPOR): bar PRESSURE: bar0 7.991 7.967 4.981 8.248 8.223 5.1442 8.511 8.486 5.3123 8.781 8.754 5.4844 9.057 9.029 5.6615 9.339 9.311 5.8416 9.628 9.599 6.0267 9.924 9.894 6.2158 10.23 10.2 6.4099 10.54 10.5 6.607

    10 10.85 10.82 6.80911 11.18 11.14 7.01712 11.51 11.47 7.22913 11.85 11.81 7.44514 12.19 12.15 7.66715 12.54 12.51 7.89316 12.9 12.87 8.12417 13.27 13.23 8.36118 13.65 13.61 8.60219 14.03 13.99 8.84820 14.43 14.38 9.121 14.83 14.78 9.35722 15.24 15.19 9.61923 15.65 15.61 9.88724 16.08 16.03 10.1625 16.52 16.47 10.4426 16.96 16.91 10.7227 17.41 17.36 11.0128 17.87 17.82 11.3129 18.34 18.29 11.6130 18.83 18.77 11.9231 19.31 19.26 12.2332 19.81 19.76 12.5533 20.32 20.26 12.8834 20.84 20.78 13.2135 21.37 21.31 13.5536 21.91 21.85 13.8937 22.46 22.4 14.2438 23.02 22.95 14.639 23.59 23.52 14.9740 24.17 24.1 15.3441 24.76 24.69 15.7142 25.37 25.3 16.143 25.98 25.91 16.4944 26.61 26.53 16.8945 27.24 27.17 17.2946 27.89 27.82 17.747 28.55 28.48 18.1248 29.23 29.15 18.5549 29.91 29.84 18.9950 30.61 30.53 19.4351 31.32 31.24 19.8852 32.04 31.97 20.3353 32.78 32.7 20.854 33.53 33.45 21.2755 34.29 34.22 21.7556 35.07 35 22.2457 35.86 35.79 22.7458 36.67 36.59 23.2459 37.49 37.42 23.7560 38.33 38.25 24.27

  • Relay RL1

    Indoor fanmotor

    * : Heat Pump Model Only

    Compressor

    Relay RL2

    * Outdoorfan motor

    Relay RL3

    * 4 way valve

    TRIAC

    DC12V

    Operating Mode

    Fan Speed

    Timer Selection

    Flap Position

    Unit on lamp

    Room air temp.

    Indoor coil temp.

    * Outdoor coiltemp

    Air clean lamp

    Quick lamp

    Remote

    Emergency

    Operation

    Signalreceiver

    Timer lamp

    A/D converter lnitialization

    Clock generation

    DC power supply

    Circuit forrelay driving

    Circuit forTRIAC control

    SMPS

    Circuit for signal receiver

    MICROCONTROLLER

    Beeper

    circuit formotor driving

    Steppingmotor

    Temp. Setting

    ON/OFF

    SLEEP

    REMOCON

    AC220V50Hz

    STEPPING MOTORON/OFF

    COMPRESSORON/OFF

    DC5V

    21

    6. CONTROL BLOCK DIAGRAM

    DSB-F074LH

  • 22

    7. TROUBLE SHOOTING

    Outdoor unit doesnot run?(note. 1)

    Doesthe com

    pressor runnorm

    ally?

    Indoor unit doesnot run(note 1)

    Check the failurecode according tothe self diagnostic

    (note 2)

    Is the unit display

    morm

    al?

    check the failure code according to

    the self-diagonostic(note 2)

    Normalcheck the connecting

    point ofm

    agneticcontactor

    YES

    YES

    YES

    YES

    NO

    NO

    YES

    Trouble

    Is the powerapplied to the

    unit

    Is the power norm

    al?check the voltage between

    L & N of terminal

    block

    press the power ON/OFF button on rem

    ote controller

    Does the beeper beep two

    times?

    Is the displayall off?

    Check the connector on displayPCB connected to control PCB Check the display PCB itself

    Check power supply mainsor interconnection wires

    Check the wiring of indoor

    Is the switch position

    on switch pannel at "Rem

    ote"

    Does control PCB

    status LED repeat one second "on and

    off"?

    control PCB fault M

    icom or reset

    IC fault Check the remote signal receiver Check the connection between signal

    receiver and control PCB

    Place the switchposition to the

    "Remote" and then

    Check it once m

    ore

    YES

    NO

    YES

    NO

    NO

    NO NO

    YES

    YES

    YES

    YES

    YES

    NO

    NO

    NO

    Is theunit display

    normal?

  • 23

    Note 1)1Neither indoor unit nor outdoor unit runs.

    Check the following points first. (There are following case in normal operation)a. Is the timer mode set the "timer ON".b. Is the timer mode set the "timer-OFF" and the time had passed?

    2Neither outdoor fan nor compressor runs while indoor fan runs.Check following points first. (There are following cases in normal operation)a. Is the temperature set point suitable?b. Has the 3 minutes time guard for compressor operated?

    Error Code 1When the compressor do not run.

    i) Check the voltage between and of terminal block.(Indoor Unit, Outdoor Unit)

    ii) Check connecting wire of indoor unit and outdoor unit. iii)Check relay RL1 on power P.C.B

    2Check fixing of indoor coil thermistor.3Check the GAS LEAKAGE of the pipe.

    YL

    Self-Diagnostic Function

  • 24

    Confirm following statement.When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.1Check the function select switch. Is it timer mode? 2The function select switch locate the sleep mode and is the setting time over?3 Is the setting mode DEHUMIDIFIER mode?4When the unit is DEHUMIDIFIER mode while in the auto mode, the outdoor unit and indoor unit does

    not run.

    The power is applied to the unit

    Check the voltge between and of terminal blockY

    LCheck the

    Breaker or Fuse

    Self Diagnosticfunction is ON

    Check according toself Diagnostic function

    Control P.C.B defect

    Check the indoor unit displayis the display all off?

    Press the ON/OFF switch ofRemote Control

    Is the indoor unit display all off?

    Pull out the power plugand then insert the power plug

    after 5 second

    Control P.C.B is normalRecheck from the beginning

    Rating voltage more than 90%

    Rating voltageunder 90%

    No No

    No

    YesYes

    Neither Indoor Unit nor Outdoor Unit Runs

  • 25

    Check rotation of indoor fan

    Rotate indoor fan by hand

    Check input Voltage of FanMotor connector at power P.C.B

    Check the winding resistance of Indoor unit fan motor

    Check the fan motor capacitor

    Check the connecting wire of indoor fan motor

    Run again

    Check the starting of indoor fan motor

    Run again

    Check the Fan Motorbearing and fan

    Check the power P.C.B.

    The circuit for triac control

    Change of fan motor

    Normal

    NO

    Rating voltageunder 90%

    Open or short

    No

    YES

    Rating Voltage more than 90%

    Normal

    Outdoor Unit Runs but Indoor Fan does Not Run

  • 26

    Confirm following statement.When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.1 Is the setting temperature proper? 2 Is the unit during 3min. Time delay of compressor.3During frost prevention of lndoor unit.4During dehumidifier mode.

    Outdoor Fan and Compressor Do Not Run

    Check the voltge between and of indoor unit terminalY

    L

    Check the voltge between and of outdoor unit terminalY

    L

    Check compressor,outdoor fan motor individually

    Check theconnecting wire

    Check the wiringand voltagewithin doors

    Rating voltageunder 90%

    Rating voltage

    under 90%

  • 27

    - Check the following at cooling mode

    Check the voltge between and of indoor unit terminalY

    L

    Check the voltge between and of outdoor unit terminalY

    L

    Check the wiring of outdoor unit

    Check the compressor(Check the winding resistance)

    Check the compressor capacitor

    Check the connectingwire between indoor

    and outdoor.

    Change the controlP.C.B

    Change thecompressor.

    Check the control P.C.Bthe circuit for relay

    driving.

    Rating voltageless than 90%

    NG

    Open or Short

    Rating voltage

    less than 90%

    Rating voltage more than 90%

    Rating voltage more than 90%

    OK

    Only Compressor does not Run

    O2 Generator/Plasma Clean System Trouble Shooting

    1. Both of the two system is switched by RL4 (on the POWER PCB) only.2. If some trouble occurs, check the RL4 and around its wiring.3. No problems in the PCB and Witing, check the Generator system or Plasma system.

    RemoteOperation

    RL4Turn ON

    O2 GeneratorMotor O2 (AH Model Only)

    High Volt (PH Model Only)High VoltGenerator

  • 28

    1 PCB CIRCUIT DIAGRAMDSB-F074LH

    8. PCB DRIVING DESCRIPTION

  • 29

    DSB-F074LH PART LIST (INDOOR UNIT)

    PART NAME SPEC QTY LOCATIONUSE 250V 50T 3.15A 1 FUSE

    FUSE CLIP AFC-520 2 FUSEVARISTOR 15G561K 1 VAR

    WAFER YW396-05AVD 1 CN2WAFER YW396-03AVD 1 CN1C-CERA 104Z,50VDC 5 CC1,2,5,6,7C-CERA 103Z,50VDC 6 CC3,4,9,10,11,12C-MULTI 104Z,CR0561B-Z5U 1 CC8C-ELEC 470uF 35V SD 1 CE1C-ELEC 10uF 450V SD 2 CE3,CE4C-ELEC 100uF 16V SD 1 CE2C-ELEC 10uF 16V SS 1 CE5C-ELEC 4.7uF 50V SS 1 CE6

    C-ARRAY F3 104Z 1 CA3C-ARRAY F4 104Z 1 CA2C-ARRAY F5 104Z 1 CA1

    RESISTOR 1/4W-12.7KF 3 R27,28,29RESISTOR 1/4W-1KJ 21 R5,12,13,14,15,16,17,18,19,20,

    R21,23,30,31,32,33,34,35,36,37,43

    RESISTOR 1/4W-10KJ 1 R11RESISTOR 1/4W-5.6KJ 1 R22RESISTOR 1/4W-330J 3 R24,25,26RESISTOR 1/4W-100J 2 R1,R4RESISTOR 1/4W-68KJ 2 R8,R9RESISTOR 1/4W-51KJ 1 R6RESISTOR 1/4W-2KJ 1 R7RESISTOR 1/2W-1KJ 1 R2 RESISTOR 1W-47J 1 R3RESISTOR 1/4W-3.24KF 1 R41RESISTOR 1/4W-49.9KF 1 R40RESISTOR 1/4W-32.4KF 1 R38RESISTOR 1/4W-24.9KF 2 R39,42

    RESISTOR ARRAY 4A 103J 1 RA3RESISTOR ARRAY 5A 103J 1 RA2RESISTOR ARRAY 6A 103J 1 RA1

    PIN GP881205-2(187) 1 CN4C-LINE ACROSS 275V 104K 2 CL1,CL2

    WAFER YFW800-01D 1 CN3WAFER SMAW250-06(WHITE) 1 CN6WAFER SMAW250-08 1 CN5WAFER YMAW250-04 1 CN7WAFER YMAW250-02 1 CN8DIODE 1N4007 TAPE 1 D3

    Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).

  • 30

    PART NAME SPEC QTY LOCATIONDIODE UF203 1 D2

    DIODE ZENOR 1N5241B 1 ZD1DIODE ST01D-200 1 D1

    C-CERA 2200pF, 250V 1 CY1CHOKE COIL 1mH, 0.5A 1 L1FILTER EMI 0.6*10*3TURN 1 L2

    BUZZER BM-20K 1 BZ1COIL 130uH, 3A 1 L3

    IC REGULATOR KIA7805P 1 IC3TR KRC102M 1 TR1

    IC RESET KIA7042P 1 IC5RELAY US11-12S 1 RL3RELAY UKH-12S 1 RL1

    SW TRANS 264P,1916 1 TRS1CAPACITOR 1uF,400VAC 1 CAP1

    PCB CONTROL 162.5X140X1.6T 1 PCBIC SWITCHING TNY264P 1 IC2DIODE BRIDGE S1NB80 1 BD1

    TRIAC SM3JZ47 1 T1PHOTO COUPLER TLP560J 1 PT1

    IC DRIVE TD62004AP 2 IC4,IC6RESONATOR CST8.00MGW 1 OSC

    IC MICOM TMP87C846AN 1 IC1PHOTO COUPLER TLP421 2 PC1,PC2

  • MODELCOOL HIGH COOL LOW HEAT HIGH HEAT LOW MONITORING

    R41 R39 R40 R38 R42

    DSB-F074LH 3.24 24.9 49.9 32.4 24.9

    MODELCOOL HIGH COOL LOW HEAT HIGH HEAT LOW MONITORING

    R28 R30 R29 R31 R27

    DSB-F154LH/PH 3.65 22.6 32.4 36.5 22.1

    MODELCOOL HIGH COOL LOW HEAT HIGH HEAT LOW MONITORING

    R33 R35 R34 R36 R37

    DSB-F184LH/PH/AH 5.76 12.4 32.4 22.1 22.1

    DSB-F244LH/PH/AH 5.76 12.4 5.76 12.4 22.1

    85

    R-OPT. DETAIL LIST

  • LED PCB ASS`Y No PART CODE PART NAME SPEC Q'TY UNIT REMARK

    CC1 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EACN1 3108804800 WAFER SMAW250-08 1 EA

    HOLD 3103002700 HOLDER LED ABS 1 EAL1 DDLS05031D LED DLSO-5031D(RED) 1 EAL2 DDLG05031D LED DLG-5031D(GRN) 1 EAL3 DDLS05031D LED DLSO-5031D(RED) 1 EAL4 DDLY05031D LED DLY-5031D(YLW) 1 EA

    PCB 3104398201 PCB LED 110*31*1.6T.10(288) 1 EARCV 1TSP1838YA RECEIVER MODULE TSOP-1838YA1(HOLDER) 1 EASW1 5S40202000 S/W PUSH JPS2281 1 EA

    LED PCB ASS`Y (MODEL : F094/F124/F184/F244)No PART CODE PART NAME SPEC Q'TY UNIT REMARK

    CC1 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EACN1 3108804800 WAFER SMAW250-08 1 EA

    HOLD 3103004100 HOLDER LED 1 EAL1 DDLS05031D LED DLSO-5031D(RED) 1 EAL2 DDLG05031D LED DLG-5031D(GRN) 1 EAL3 DDLS05031D LED DLSO-5031D(RED) 1 EAL4 DDLY05031D LED DLY-5031D(YLW) 1 EA

    PCB 3104398202 PCB LED 150*24.5*1.6T(240) 1 EARCV 1TSP1838YA RECEIVER MODULE TSOP-1838YA1(HOLDER) 1 EASW1 5S40202000 S/W PUSH JPS2281 1 EA

    LED PCB ASS`Y (MODEL : F154)No PART CODE PART NAME SPEC Q'TY UNIT REMARK

    CC1 CXCH1H103M C CERA 103J/50 20% 1 EACN1 3108804600 WAFER SMAW250-07 1 EA

    HOLD 3103001100 LED HOLDER ABS (BLK) 1 EAL1 DDSR302D-- LED DLSR-302D(RED) 1 EAL2 DDLG302D-- LED DLG-302D 1 EAL3 DDSR302D-- LED DLSR-302D(RED) 1 EAL4 DDLY302D-- LED DLY-302D 1 EA

    PCB 3104395412 LED PCB 67.5*40*1.6T(350) 1 EARCV 1TSP1838YA RECEIVER MODULE TSOP-1838YA1(HOLDER) 1 EA

    SWITCH PCB ASS`Y (MODEL : F154)No PART CODE PART NAME SPEC Q'TY UNIT REMARK

    CN1 3108804700 WAFER SMAW250-02 1 EAPCB 3104395311 S/W PCB 36*29.5*1.6T(891) 1 EASW1 5S30101330 SWITCH SLIDE KSA-2340B 1 EA

    86

  • 33

    Power Supply(1)

    DESCRIPTION

    DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac DrivingPhoto Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified byBridge Diode, and it is filtering by Main Condensor CE1.Filtered DC voltage is about +18V, is regulated +12V DC by Regulator IC7812.And it is regulated +5V DC by Regulator IC7805.VAR is serge filter and CC1, CC2, CC3 is Noise filter.

    AC 220V

    CL1

    275V104K

    VAR

    FUSE1

    3.15A

    POWER TRANS

    D2CC1 CE1

    D3

    D1

    D4104

    +

    35V1000F

    IC27812

    VI VO

    G

    IC37805VI VO

    G+25V470F

    CC2 CC3 CE3CE2

    104+

    16V100F

    104

    12V 5V

    Oscillator(2)

    19OSC

    CC13104

    5V

    8M20

  • 34

    Room temperature and Evaporator temperature Sensor Input

    DESCRIPTION

    Number 24, 25 of Micom is Terminal of A/D convertor Input.Room temperature and Evaporator temperature is sensing by change of Thermister Resistance, Micom is putin 5V by ratio between R10 (12.7K) and R11 (12.7K).Relation between temperature and voltage is following Table 3-1.CC5, 6 is Noise filter.

    Temperature(C) No. 1 No. 3-5 1.127 1.127

    0 1.378 1.378

    5 1.650 1.650

    10 1.936 1.936

    15 2.228 2.228

    Voltage (V)

    Table 3-1

    Sensor(3)

    070LH,091LH182LH, 240LH

    O/C SENSOR

    I/C SENSOR

    ROOM SENSOR

    CN10

    330 R8

    R7

    R6

    330

    330CC5103

    R912.7kF

    CC7103

    103CC6

    23

    24

    25

    MICOM

    CN9

    R1012.7KF

    R1112.7KF

    VDD-10%

    VSS+10%Fig 2-1

    DESCRIPTION

    Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency.Ocillatory wave is as following Fig 2-1.

  • 35

    Triac Driving(4)

    DESCRIPTION

    Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is suppliedTrigger Signal.Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Timedelay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.

    N

    LAC 220V

    TO MOTOR

    T1SM3JZ47

    L11 2

    130H3A

    SN10.1F120Ohm

    TLP561PT1

    12V

    R5

    1K1/2W

    IC4KID 65004

    MICOM

    38 2 15

    AC220V

    TRIGGER

    MOTORINPUT

    LOW SPEED MEDIUM SPEED HIGH SPEED

    Fig 4-1

    LOW SPEED MEDIUM SPEED HIGH SPEED

  • 36

    DESCRIPTION

    Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gottenfid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.But in Secondary Wave Custom Code is Reversed Face.

    LEADER CODECUSTOM

    CODEDATACODE

    CHECKSUM

    TAILER

    9ms 4.5ms 16bit 16bit24bit 8bit

    Fig 5-1 Fig 5-2BIT STRUCTURE

    Remote Controller(5)

    0.56ms 0.56ms1.69ms

    1.12ms 2.25msbit 0 bit 1

    Selecting Mode(6)

    (SELECT S/W INPUT, OUTPUT)

    MICOM13

    R141K

    RA1

    5V

    CA1F4104Z

    P2MODESELECTPUSH S/W

    DESCRIPTION

    There are Mode according to SW position asfollowing Table 6-1.According as port of fixed Micom is Low, the unit isoperating as following Table 6-1.

    Table 6-1

    POSITION MODE OPEN REMOCONGND EMERGENCY

  • 37

    DESCRIPTION

    MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.

    Micom Power Supply(7)

    VDD 42CE5

    10F16V

    CC11104

    CC13104

    +

    5V

    414039

    2221

    19OSC8MHz

    20

    VSS

    MICOM

  • 38

    DESCRIPTION

    Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detectPower ON and Voltage less than 4.25V, and then send Reset Signal.

    Reset(8)

    R13 5.6K

    1K R1218

    CC9

    CE4

    4.7uF/50V

    IC57042P

    10.3

    MICOM

    4.25V

    H

    L t

    t

    POWERON

    Vcc (+5V)

    DELAY TIMEFOR POWER ON

    RESET

  • 39

    DESCRIPTION

    Micom 34 Terminal put out Buzzer Driving Pulse,its output is driving Buzzer through Buffer.Ocillatory Frequency of buzzer is selected byinternal Micom.This unit is setting at 4KHz.

    VCC12V

    KID 65004

    MICOM

    34 6 11

    R41K BZ1

    Buzzer Driving(10)

    DESCRIPTION

    Selecting function is as following table 9-1.* When power source is put at fist, Funtion selection input is recognized.

    And when the unit is running the microcomputer ignore variation of funtion selection input.

    JS3

    JS2

    JS1

    1K14

    15

    16

    30

    29

    28

    41

    40

    39

    27

    26

    1K

    1K

    1K

    1K JS5

    JS41K

    1K

    1K

    1K

    1K

    R28

    R32

    R31

    R30

    R25

    R24

    R23

    R35

    R34

    R33

    R37R29

    1K

    R17

    MICOM

    R16

    R15

    CA2

    CA1F5 104Z

    RA1 R36 heat/low

    heat/high

    cool/low

    cool/high

    monitoring

    6A

    RA3RA3

    4A 103JCA3F3 104Z

    103J

    RA2

    Function Selecting(9)

    MODELSwing direction Turbo(heating) Flap angle Heating/Cooling Ultra low TEST Oxygen/Plasma

    JS1 JS2 JS3 JS4 JS5 JS6 JS7DSB-F074LH X X X O O X ODSB-F094LH X X X O O X O

    DSB-F094PH/AH X X X O O X XDSB-F124LH X X X O O X O

    DSB-F124PH/AH X X X O O X X

    MODELSwing direction Turbo(heating) Flap angle Heating/Cooling Ultra low TEST Oxygen/Plasma

    JS1 JS2 JS3 JS4 JS5 JS6 J17DSB-F184LH X X X O O O

    DSB-F184PH/AH X X X O O XDSB-F244LH X X X O O O

    DSB-F244PH/AH X X X O O X

    MODELSwing direction Turbo(heating) Flap angle Heating/Cooling Ultra low TEST Oxygen/Plasma

    JS1 JS2 JS3 JS4 JS5 JS6 J21DSB-F154LH O X O O ODSB-F154PH O X O O X

  • 40

    DESCRIPTION

    It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom. Detail Driving is as following Fig 11-1.R19 is Resistance to limit current.

    MICOM

    TRANSOUTPUT

    D5

    D6 R25.6K

    12

    CC4103

    TR1KRC120M

    1 2 1

    23

    2 1

    R310K

    R271K

    VCC

    31

    DETECT POINT

    H

    TheNumber31 ofMicomterminal

    AC18V

    L

    Fig 11-1

    Zero Crossing Detect(11)

  • 41

    DESCRIPTION

    There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.It is driving as following Fig 12-1. (Ring Count Method of 8 Status)

    4

    3

    2

    1

    B+

    6

    5

    4

    3

    2

    1

    12V

    IC6

    KID65004

    CN13

    1

    MICOM2

    3

    4

    M1FOR SWING

    4

    3

    2

    1

    Fig 12-1(Normal Rotating) (Reversed Rotating)

    Stepping Motor Driving(12)

  • 42

    (1) U1 (MICOM)

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    VDD

    (XTOUT)P22(XTIN)P21

    (INT5/STOP)P20P17

    P16

    (TC2)P15(PPG)P14(DVO)P13

    (INT2/TC1)P12(INT1)P11(INTO)P10(AIN7)P67(AIN6)P66(AIN5)P65(AIN4)P64(AIN3)P63(AIN2)P62(AIN1)P61(AIN0)P60

    VAREF

    P77(HSO)P76(HSCK)P75(SO)P74(SI)P73(SCK)P72(PDO/PWM)P71(INT4)P70(INT3/TC3)P07

    P06

    P05

    P04

    P03

    P02

    P01

    P00

    TESTRESETXIN

    XOUT(VASS)VSS

    42

    41

    40

    39

    38

    37

    36

    35

    34

    33

    32

    31

    30

    29

    28

    27

    26

    25

    24

    23

    22

    Steppping MotorDriving

    Indoor Unit Motor Driving

    Buzzer DrivingRemocon Input

    Comp Relay DrivingZero Crosing Detect

    Function S/W

    TemperatureSensor Input

    LED Driving

    EmergencyMode

    FunctionS/W

    Reset Curcuit

    Oscillation

    2 KEY COMPONENTS OF ELECTRONIC CIRCUIT

  • 43

    (2) U2, 4 (KID65004) DARLINGTON ARRAYS

    (3) U8 (KIA7805P) : VOLTAGE REGULATOR (5VDC)

    (4) U7 (KIA7812P) : VOLTAGE REGULATOR (12VDC)

    IN1 1 16 OUT 1IN2 2 15 OUT 2IN 3 3 14 OUT 3IN 4 4 13 OUT 4IN5 5 12 OUT 5IN6 6 11 OUT 6IN7 7 10 OUT 7

    GND 8 9 COMMON FREE WHEELING DIODES

    COMMON

    10.5K7.2K

    3K

    OUTPUT

    GND

    INPUT

    100K 500 100 100

    0.3

    10K

    6K

    500

    1K 5K

    28K

    6K

    30pF

    2K

    5K

    200

    240

    1.4 K2.7

    K

    3.3 K

    0.19K

    INPUT

    OUTPUT

    GND

    SCHEMATIC DIAGRAM

    123

    Fin 2 is groundfor Cose 221A.Case is groundfor Case 1.

    10KINPUT

    GND

    10K

    300

    36K

    64K

    520

    26K60K

    29K20K

    20K

    40pF

    50K

    50 200

    300

    200

    10016K

    210

    012

    OUTPUT

    (Top View)

    Pin 1. INPUT2. GROUND 3. OUTPUT

    Pin 1. INPUT2. GROUND 3. OUTPUT

    (Equivalent Circuit)

    KID65004AP

    (Equivalent Ciircuit)

  • 44

    (5) U9 (KIA7042P) : RESET IC

    KIA7042P

    OUTLINEINPUTGROUNDOUTPUT

    VCC1

    3

    2

    OUT

    GND

  • 45

    ERRORNo

    ERRORNo

    ERRORNo

    No

    No

    NoYes

    Select ON/OFF button

    Select Mode button

    Select FAN SPEED button

    Select FAN DIR. button

    Power Supply

    TEST STARTPower supply again

    Check the FollowingBATTERY SPRINGMICOMPCBLCD

    Is Display at thebeginning ON?

    Is Display at thebeginning ON?

    Is it normal?

    Is it normal?

    Is it normal?

    3 REMOTE CONTROLLER ASSMBLY FUNCTIONAL TEST METHOD

    ERRORNo

    ERRORNo

    (Whenever you selectted Temp.Button, it is changed by 1C (18~32C)

    ( )

    Select TEMP. Button (,)

    Select ON/OFF button

    Is display at thebegining ON?

    Is it normal?

  • 46

    (0.5~24 HOUR)

    ERRORNo

    Select TIMER ON Button

    Select Timer Enter Button

    Select CANCEL Button

    Select ON/OFF Button

    Select OFF (Timer) Button

    Select SLEEP Button

    Select SLEEP Button

    TEST OK!

    Is LCD display OFF?

    Is it normal

    display?TIMER

    Is all display OFF?

    Is it normal?

    SLEEP MODEDisplay ON?

    Is display at thebeginning ON?

    ERRORNo

    ERRORNo

    ERRORNo

    ERRORNo

    ERRORNo

    ERRORNo

  • 47

    1 INDOOR UNIT

    9. DISASSEMBLY INSTRUCTIONS

    PROCEDURES PHOTOS

    1. Stop the operation of the Air conditioner and disconnect the power cordfrom the wall outlet.

    2. Removing the Insert Grille and Frame Grille. (Fig 1~2)1Draw up the Insert Grille and remove it.2Loosen the screw fixed at the Cover Ter-Block.3Loosen two screws fixed at the Frame Grille.4Remove the Frame Grille.

    3. Removing the Control Box. (Fig 3)1Remove room and coil thermistors.2Disconnect the fan motor lead wire from connection at the

    Control PCB.3Disconnect the stepping motor lead wire from connection at the

    Control PCB.4Remove the select switch from connection at the Control PCB.5Loosen the screw fixed at the ground wire.6Remove the Control Box

    4. Removing the Drain Pan. (Fig 4)1Disconnect the Body drain hole. (left and right Body)2Disconnect three hooks and remove the Drain Pan.

    5. Removing the Indoor Evaporator. (Fig 5~6)1Remove the screw fixed at the indoor Evaporator of the Body.2Remove the hook fixed at the Bracket Pipe of the back of Body.3Remove Indoor Evaporator.

    6. Removing the Cross Flow Fan. (Fig 7)1Remove set screw fixed at the Motor shaft.2Remove Cross Flow Fan.

    7. Remove Motor IDU and Bearing Plastic.

    Fig 1

    Fig 3

    Fig 4

    Fig 5

    Fig 6

    DSB-F074LH

    Fig 2

    Fig 7

  • 48

    2 OUTDOOR UNIT

    DSB-F074LHPROCEDURES PHOTOS

    1.Stop the operation of the air conditioner and disconnect the wire fromIndoor Unit to Outdoor Unit.

    2. Disassemble the case. (Fig 1~2)1Remove the Top Panel. (Loosen thirteen screws)2Remove the Front Cabinet. (Loosen six screws)3Remove the Side Cabinet. (Loosen seven screws)4Remove the Guide Support. (Loosen two screws)

    3. Removing the Propeller Fan. (Fig 3)1Loosen the Nut fixed at the the Propeller Fan.2Remove the Plain Washer.3Remove the Propeller Fan.

    4. Removing the Motor ODU. (Fig 4)1Loosen four screws fixed at the Bracket Motor.2Disconnect the wire at the Control Panel and remove the Motor ODU.

    5. Removing the Dual Capacitor. (Fig 5)1Disconnect the wire at the Control Panel.2Loosen the screw fixed at the Clamp Capacitor.3Remove the Dual Capacitor.

    6. Removing the Over load Protector. (Fig 6~7)1Loosen the Hex Nut at Terminal Cover.2Remove the Terminal Cover.3Remove the wire at the Over load Protector.4Remove the Over load Protector.

    Fig 5

    Fig 4

    Fig 6

    Fig 7

    Fig 1

    Fig 3

    Fig 2

  • 49

    3 EXPLODED DIAGRAM (Indoor Unit)DSB-F074LH

  • 50

    DSB-F074LH PART LIST (INDOOR UNIT)

    No PART CODE PART NAME Q'TY SPEC REMARK1 3100400301 BODY 1 HIPS T2.02 3108008700 MOTOR IDU 1 YDK-8-4B3 3101500400 CUSHION MOTOR 2 CR 304 3106400400 BEARING PLASTIC Ass`y 15 3100053700 FAN CROSS FLOW Ass`y 1 90.0 x L5406 7485401012 SET SCREW 1 6S-4x10-E MFZN7 3103002601 HOLDER MOTOR 1 HIPS T2.08 3110050820 EVAPORATOR Ass`y 19 3102501220 GUIDE EVA. 1 PVC L536xT0.710 3100603800 BRACKET PIPE 1 HIPS T2.011 3108100801 PAN DRAIN 1 HIPS T2.012 3106001600 BLADE VERTICAL 3 P.P. T1.513 3108003900 MOTOR STEPPING 1 MP24GA , GSP-24SW-06114 3107600400 FLAP 1 HIPS T2.515 3101404800 COVER WIRE L 1 HIPS 16 3101404900 COVER WIRE R 1 HIPS17 3100054202 LED PCB Ass`y 118 3100901600 CAP RUBBER 1 SILICON19 3110051130 CONTROL BOX Ass`y 1

    19-1 3100508400 CONTROL BOX 1 P.P. + G.F. 20%19-2 3114302030 CONTROL PCB Ass`y 119-3 3108912310 TERMINAL BLOCK 1 SN-DBW-05P19-4 3104896300 SENSOR ID Ass`y 1 PTM-KD-43C-D219-5 3101300100 POWER CORD Ass`y 1 16A 250V19-6 3101203000 CLAMP WIRE 1 P.P. + G.F. 20%19-7 3102797910 HARNESS 1 EARTH I/D19-8 3112704470 HARNESS AC SIGNAL 2 1 UL1015 WHITE(L6000)20 3100400410 BODY-TOP 1 HIPS T2.021 3102200800 FRAME GRILLE 1 HIPS T2.522 3104508700 PLATE LED 1 P.C. Sheet T2.023 3104510200 PLATE SWITCH 1 P.C. Sheet T2.024 3101404600 COVER TERMINAL BLOCK 1 HIPS T2.025 3101100400 CASE FILTER 2 P.P. T2.026 3101902510 FILTER CARBON Ass`y 1 Black27 3101902610 FILTER ELECTRO Ass`y 1 White28 3102200900 FILTER FRAME 2 P.P. T2.029 3112400820 INSERT GRILLE 1 HIPS T2.530 3115500500 COVER LED 1 ABS() T2.031 3104507200 PLATE MOUNTING 1 SBHG 1 T0.7

    Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).

  • 51

    DSB-F074LH

    4 EXPLODED DIAGRAM (Outdoor Unit)

  • 52

    DSB-F074LH PART LIST(OUTDOOR UNIT)

    No PART CODE PART NAME Q'TY SPEC REMARK

    1 3100014730 PAN BASE ASSY 12 3116005510 BOLT COMP 3 M8 x L45.53 3102100800 FOOT 2 SECC T1.24 COMP. GROMMET 3 EPDM

    3117143600 1 G4C072JU1ER DSB-F074LH5 COMPRESSOR ASSY

    6 7400208411 COMP. WASHER 3 M8.4 x 22 xT1.67 7392801211 COMP. NUT 3 M8 x P1.25 MFZN8 311009JB00 CONDENSER ASSY 1 L465xW208.5xH5089 311009JC00 PIPE COND. IN 110 311009JD00 PIPE COND. OUT 111 3100602210 BRACKET SERVICE 1 SECC T1.212 3110051700 SERVICE VALVE 1 3/8"13 3110051810 SERVICE VALVE 1 1/4"14 7347602011 BOLT HEX 4 M6 x L20 MFZN

    311009JM00 1 DSB-F074LH15 PIPE REVERSING ASSY

    16 3115404800 CHECK VALVE 1 12.73114476300 1 O.D3.2xI.D1.4xL5003114474400 PIPE CAPILLARY COOL 1 O.D3.2xI.D1.4xL700

    173114476600 1 O.D3.2xI.D1.6xL10003114476400 1 O.D3.2xI.D1.4xL7003114474500 PIPE CAPILLARY HEAT 1 O.D3.2xI.D1.4xL7003114476700 1 O.D3.2xI.D1.6xL700

    18 3102501100 GUIDE SUPPORT 1 SECC T1.219 3102402600 GRILLE COND. 1 PE 660x525.5xT3.520 3100601903 BRACKET MOTOR 1 SBHG1 T1.2

    3108008900 1 YDK-30-6B DSB-F074LH21 MOTOR ODU

    22 3101801000 FAN PROPELLER 1 ABS+G/F20% (BLACK)23 7400208411 WASHER PLAIN 1 PW-2-8 MFZN24 7392800011 NUT LOCK 1 M8xP1.25 MFZN25 3114504110 PLATE PARTITION 1 SGCC T1.026 314201900 PANEL CONTROL 1 SBHG1 T0.827 3108912310 TERMINAL BLOCK 1 SN-DBW-05P

    3109505720 1 1.8+30F / 450VAC DSB-F074LH28 CAPACITOR DUAL

    Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).

  • 53

    No PART CODE PART NAME Q'TY SPEC REMARK

    29 3101201100 CLAMP CAPACITOR 1 SBHG1 T1.030 3101202000 CLAMP CORD 1 NYLON 31 3110801500 CABINET FRONT 1 SECC T0.832 3112402500 GRILLE DISCHARGE 1 RECTANGULAR33 3103510700 LABEL BRAND 1 P.CFILM 346x90xT0.434 3100801300 CABINET SIDE 1 SECC T0.835 3104201800 PANEL TOP 1 SECC T0.836 3102600300 HANDLE 1 A.E.S T2.5 (WH104A)37 3102101000 FOOT CUSHION 4 NBR

  • 54

    DSB-F074LH

    5 CONTROL BOX ASSEMBLY

  • 55

    DSB-F074LH

    No PART CODE PART NAME Q'TY SPEC REMARK

    13114302030

    CONTROL PCB ASS'Y 1DSB-F074LH

    2 3108003900 MOTOR STEPPING 1 MP24GA , GSP-24SW-061

    3 3108914300 TERMINAL BLOCK 1 JXO-CH-05P 600V 30A

    5 3104896300 SENSOR ID ASS'Y 1 PTM-KD43C-D2

    6 3101300100 POWER CORD ASS'Y 1 250V 16A H05VV-F 3 x 1.0mm2

    7 3102797610 HARNESS I/D COMP 1 UL1015 #18 BLU

    8 3102797150 HARNESS 4WAY VALVE 1 UL1015 #20 BLK

    9 3102704400 HARNESS O/D MOTOR 1 UL1015 #20 WHT

    10 3102797910 HARNESS I/D EARTH 1 UL1015 #16 GRN/YEL

    11 3102704000 HARNESS POWER 1 UL105 2 x #16 BRN,BLU

    12 3102702200 HARNESS TH3 1 UL2464 2x #24 x 6000

    13 3102704500 HARNESS LED PCB 1 UL1007 8x #24 WHT

    14 3101204600 CLAMP CORD 1 DA-4N

    15 3106900300 CAPACITOR IDU 1 1.0 F 400VAC

    Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).