Hydraulics A44 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA Directional Control Valves Catalog 2502/USA A Application Parker D3 Series hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3 position. They are manifold mounted which conform to NFPA’s D05/CETOP 5 mounting patterns. These valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency. Operation Parker’s D3 Series directional control valves consist of a four chamber style body, and a case hardened sliding spool. The spool is directly shifted by a variety of operators including: solenoid, lever, cam, or air pilot. D3W Solenoid Operated Conduit Box Style D3W Solenoid Operated Hirschmann (DIN) Style Easy access mounting bolts No tools required for coil removal 22 spool styles available Three electrical connection options AC & DC lights available CSA approved Available in low-watt DC version DIN Style (43650) Hirschmann Dual spade (SAE type 1B) lug style also available 22 spool styles available No tools required for coil removal Easy coil replacement AC & DC lights available CSA approved Available in low-watt DC version Introduction Series D3 D3W Soft Shift Tube Repairable Override Assembly 9/16" Hex Response Time Control Orifice** Orifice** Removal Tool ½" Hex 5/32" Wrench Not Supplied ** Orifice Removal Tool with Kit Part Number 1301661

DocumentD3

Embed Size (px)

Citation preview

Page 1: DocumentD3

Hydraulics A44

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

AApplication

Parker D3 Series hydraulic directional control valvesare high performance, direct operated 4-way valves,available in 2 or 3 position. They are manifoldmounted which conform to NFPA’s D05/CETOP 5mounting patterns. These valves were designed forindustrial and mobile hydraulic applications whichrequire high cycle rates, long life and high efficiency.

Operation

Parker’s D3 Series directional control valves consistof a four chamber style body, and a case hardenedsliding spool. The spool is directly shifted by avariety of operators including: solenoid, lever, cam,or air pilot.

D3W Solenoid Operated Conduit Box Style

D3W Solenoid Operated Hirschmann (DIN) Style

• Easy access mounting bolts

• No tools required for coilremoval

• 22 spool styles available

• Three electrical connectionoptions

• AC & DC lights available

• CSA approved

• Available in low-watt DCversion

• DIN Style (43650)Hirschmann

• Dual spade(SAE type 1B) lug stylealso available

• 22 spool styles available

• No tools required for coilremoval

• Easy coil replacement

• AC & DC lights available

• CSA approved

• Available in low-watt DCversion

Introduction Series D3

D3W Soft Shift TubeRepairable

Override Assembly 9/16" Hex

Response TimeControl Orifice**

Orifice** Removal Tool½" Hex

5/32" WrenchNot Supplied** Orifice Removal Tool with Kit Part Number 1301661

Page 2: DocumentD3

Hydraulics A45

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Features

• Easy access mounting bolts

• 345 Bar (5000 PSI) pressure rating

• Flows to 40 GPM depending on spool

• Choice of four operator styles

• Rugged four land spools

• Low pressure drop

• Phosphate finish body

• CSA approved and UL recognized(except manual operators)

• Proportional spool available

D3L Lever Operated

• Spring return or detent styles available

• Heavy duty handle design

• High flow, low pressure drop design

D3A Air Operated

D3C Cam Operated

• Low pilot pressure required –3.4 Bar (50 PSI) minimum

• Manual overrides standard

• High flow, low pressure dropdesign

• Choice of 2 cam roller positions(D3C and D3D)

• Short stroke option

• High flow, low pressure dropdesign

Introduction Series D3

Page 3: DocumentD3

Hydraulics A46

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

AApplication

Parker D3D Series hydraulic directional control valvesare high performance, direct operated 4-way valves,available in 2 or 3 position. They are manifoldmounted which conform to NFPA’s D05/CETOP 5mounting pattern. These valves were designed forindustrial and mobile hydraulic applications whichrequire high cycle rates, long life and high efficiency.

Operation

Parker’s D3D Series directional control valvesconsist of a five chamber style body, and a casehardened sliding spool.

D3DW Solenoid Operated Hirschmann (DIN) Style

• Easy access mounting bolts

• No tools required for coilremoval

• 22 spool styles available

• Signal lights available

• CSA approved

Introduction Series D3

Page 4: DocumentD3

Hydraulics A47

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Maximum Flow, LPM (GPM)350 Bar (5000 PSI)w/o Malfunction

Model Spool Symbol D3W D3W*F† D3DW

D3*1 150 (40) 78 (20) 130 (33)

D3*2 150 (40) 78 (20) 115 (30)

D3*3 150 (40) 78 (20) 120 (31)

D3*4 150 (40) 59 (15) 130 (33)

D3*5 150 (40) 78 (20) 130 (33)

D3*6 150 (40) 78 (20) 130 (33)

D3*7 50† (13) 59# (15) 70† (18)

D3*8 50‡ (13) 59# (15) 39 (10)

D3*9 39 (10) 59# (15) 75 (19)

D3*10 115 (30) N/A 75 (19)

D3*11 115 (30) 59# (15) 130 (33)

D3*12 95 (24) 59 (15) 75 (19)

D3*14 50† (13) 59# (15) 70† (18)

D3*15 150 (40) 78 (20) 120 (31)

D3*16 150 (40) 78 (20) 130 (33)

D3*20 150 (40) 78 (20) 130 (33)

D3*21 115 (30) N/A 120 (31)

D3*22 115 (30) N/A 120 (31)

D3*26 115 (30) N/A 75 (19)

D3*30 39 (10) 59# (15) 75 (19)

D3*81 115† (30) N/A 130 (33)

D3*82 115† (30) N/A 130 (33)

D3 Quick Reference Data

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

D3L, D3A, D3C Quick Reference Data (Four Chamber Body Only)Maximum Flow, LPM (GPM)

350 Bar (5000 PSI)Model Spool Symbol w/o Malfunction

D3*1 150 (40)

D3*2 150 (40)

D3*4 150 (40)

D3*8 50 (13)

D3*9 39 (10)

Maximum Flow, LPM (GPM)350 Bar (5000 PSI)w/o Malfunction

Model Spool Symbol D3W D3W*F† D3DW

D3*20 150 (40)

D3*26 115 (30)

D3*30 39 (10)

D3*81 115 (30)

D3*82 115 (30)

Center or De-energized position is indicated by P, A, B & T port notation.† 3000 PSI Max. ‡ 4300 PSI Max. # 1500 PSI Max.

Maximum Flow, LPM (GPM)350 Bar (5000 PSI)

Model Spool Symbol w/o MalfunctionA B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

Center or De-energized position is indicated by A, B, P & T port notation.

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

Technical Information Series D3

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

Page 5: DocumentD3

Hydraulics A48

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A

Performance Curves Series D3W

D3W-30 DC and AC Rectified Shift Limits

D3W-30 Low Watt DC and AC Rectified Shift Limits

Important Notes for Switching LImit Charts1. For F & M style valves, reduce flow to 70% of that shown.2. Shift limits charted for equal flow A and B ports. Unequal

A and B port flows may reduce shift limits.

Example:

Determine the maximum allowable flow of a D3W Seriesvalve (20D) at 150 Bar (2175 PSI) supply pressure.Locate the curve marked "20D". At 150 Bar (2175 PSI)supply pressure, the maximum flow is 98 LPM (25 GPM).At 345 Bar (5000 PSI), the flow is 72 LPM (18.5 GPM).

PSI Bar

5000

4000

3000

2000

1000

0

50

100

150

200

250

300

345

Sup

ply

Pre

ssur

e

LPM0

GPM

10 20 30

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

40 50 60 70 80

Flow

90 100 110 120 130 140 150

8

20D, 26D30D

12

10, 21,22, 26

7, 14

9, 30

8, 9, 30

1, 2, 3,4, 5, 6,

15, 16, 20

11, 81, 82

0LPM

0GPM

10 20 30

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

40 50 60 70

Flow

3000

2000

1000

PSI Bar

50

100

150

200

Su

pp

ly P

ress

ure 4

1, 2, 3,5, 6,

15, 16, 207, 8, 9

11, 12, 14,30

Page 6: DocumentD3

Hydraulics A49

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Performance Curves Series D3W

D3W-30 AC Shift Limits

D3W-30 Soft Shift Limits

PSI Bar

5000

4000

3000

2000

1000

0

50

100

150

200

250

300

345

Su

pp

ly P

ress

ure

LPM0

GPM

10 20 30

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32

40 50 60 70 80

Flow

90 100 110 120

6

7, 8,14

9

112

12

20D,30D

1, 3, 4, 5,15, 16,20, 30

1, 6, 203, 4, 5,

15, 16, 30

PSI Bar

5000

4000

3000

2000

1000

0

50

100

150

200

250

300

345

Sup

ply

Pre

ssur

e

LPM0

GPM

10 20 30

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

40 50 60 70 80

Flow

90 100 110 120 130 140 150

1,2,5,6,16,20,81

12

8, 9

20D, 26D,30D

12

3, 4, 11,15, 30

7, 8, 9,10, 14,

21, 22, 26,82

Important Notes for Switching LImit Charts1. For F & M style valves, reduce flow to 70% of that shown.2. Shift limits charted for equal flow A and B ports. Unequal

A and B port flows may reduce shift limits.

Page 7: DocumentD3

Hydraulics A50

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A

Performance Curves Series D3DW

D3W-30 Soft Shift Response

D3DW-40 Shift Limits

Important Notes for Switching LImit Charts1. For F & M style valves, reduce flow to 70% of that shown.2. Shift limits charted for equal flow A and B ports. Unequal

A and B port flows may reduce shift limits.

PSI Bar

5000

4000

3000

2000

1000

0

50

100

150

200

250

300

345

Sup

ply

Pre

ssur

e

LPM0

GPM

10 20 30

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36

40 50 60 70 80

Flow

90 100 110 120 130

12

2

7, 14

8

10, 26

20D, 26D, 30D

9, 30

1, 4, 5, 6, 11, 1215,16, 20, 81, 82

3,21, 22

Response Time*Signal to 95% spool stroke measured at172 Bar (2500 PSI) and 65 LPM (17 GPM).

% o

f Max

imum

Sho

ck

E = EnergizeD = De-energize

100

80

60

40

20

0

StandardValve

Soft Shift"S7"

Soft Shift"S4"

E D E D E D

Shock Load

Soft ShiftOption Energize De-energize

S4 320 550

S7 160 370

* For reference only. Response time varies withflow, pressure and oil viscosity.

Page 8: DocumentD3

Hydraulics A51

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Technical Information Series D3

Pressure Drop vs. Flow

The table shown providesflow vs. pressure drop curvereference for D3 Series valvesby spool type.

The chart below demonstratesgraphically the performancecharacteristics of the D3. Thelow watt coil and other designfeatures of the standardD3W*****F accommodate amaximum flow of 78 L/M(20 GPM) at 207 Bar (3000PSI).

D3W/D3DW Pressure Drop Reference Chart

Curve Number

Spool Shifted Center Condition

No. P–A P–B B–T A–T (P–T) (B–A) (A–B) (P-A) (P-B) (A-T) (B-T)

1 5 5 2 2 — — — — — — —2 4 4 1 1 2 3 3 3 3 1 13 5 5 2 3 — — — — — 1 —4 4 4 3 3 — — — — — 1 15 6 5 2 2 — — — 2 — — —6 6 6 2 2 — 4 4 2 2 — —7 5 4 2 1 3 — — — 3 — 18 8 8 7 7 6 — — — — — —9 5 5 4 4 7 — — — — — —

10 5 5 — — — — — — — — —11 5 5 2 2 — — — — — 10 1012 5 5 2 2 11 — — 10 10 10 1014 4 5 1 2 3 — — 3 — 1 —15 5 5 3 2 — — — — — — 116 5 6 2 2 — — — — 2 — —20 5 5 2 2 — — — — — — —21 5 4 — 1 — 9 — — — — —22 4 5 1 — — — 9 — — — —26 5 5 — — — — — — — — —30 5 5 2 2 — — — — — — —

Viscosity Correction Factor

Viscosity 75 150 200 250 300 350 400(SSU)% of ∆P 93 111 119 126 132 137 141(Approx.) Curves were generated using 110 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart.Performance Curves

PSI Bar

350

280

210

140

70

0

5

10

15

19

24

Pre

ssu

re D

rop

LPM0

GPM

10 20 30

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

40 50 60 70 80

Flow

90 100 110 120 130 140 150

#11

#10

#9 #8

#7

#6

#1

#2

#5

#4

#3

Note:For 81 and 82spools, consultfactory.

Page 9: DocumentD3

Hydraulics A52

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A

Interface NFPA D05, CETOP 5, NG 10

Max. Operating P, A, B:Pressure 345 Bar (5000 PSI) Standard

CSA 207 Bar (3000 PSI)

Tank:103 Bar (1500 PSI) Standard

CSA 103 Bar (1500 PSI)

Specifications

Technical Information Series D3W

General Description

The D3W Series directional control valves are high-performance, 4-chamber, direct operated, wet arma-ture solenoid controlled, 3 or 4-way valves. They areavailable in 2 or 3-position and conform to NFPA’sD05/CETOP 5 mounting patterns.

Features

• Worldwide, high flow, low pressure drop design.

• Mechanically tunable soft shift.

• 22 spools available including proportional.

• Repairable manual override for easy seal replacement.

• DC surge suppression available to protect electricalequipment.

• Three electrical connection options.

• AC & DC lights available.

• Easy access mounting bolts.

• Explosion proof availability.

• CSA approved.

• No tools required for coil removal.

• Rectified coils available for high flow AC applications.

Response Time (ms)Signal to 95% spool stroke measured at172 Bar (2500 PSI) and 75 LPM (20 GPM)

Solenoid Type Pull-In Drop-Out

AC 21 35DC 110 85

AA BB

P T

Page 10: DocumentD3

Hydraulics A53

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Solenoid Ratings**

Insulation Class HAllowable Deviationfrom rated voltage -10% to +15%Armature Wet pin type

** DC Solenoids available with optional molded metal oxide varistor(MOV) for surge suppression.

Leadwire length 6” from coil face.

D3W Solenoid Electrical Characteristics†

Solenoid Nominal In Rush Holding NominalCode Volts/Hz VA VA Watts (Ref)

Y 120/60 298 95 32110/50 294 102

T 240/60 288 96 32220/50 288 101

E 24/60 290 77 3224/50 381 110

K 12 VDC — 3.00† 36

J 24 VDC — 1.50† 36

D 120 VDC — 0.30† 36

† DC holding amps.

Electrical Characteristics* ED and EU†

Solenoid Nominal In Rush Holding NominalCode Volts/Hz VA VA Watts (Ref)

Y 120/60 266 82 36

T 240/60 266 82 36

K 12 VDC — 3.00† 36

J 24 VDC — 1.50† 36

D 120 VDC — 0.30† 36

*Dual frequency not available on explosion proof coils.

† DC holding amps.

Explosion Proof Solenoid Ratings

U.L. (EU) Class I, Div. 1 & 2, Groups C & DC.S.A. Class II, Div 1 & 2, Groups E, F & G

As defined by the N.E.CCENELEC (ED) Complies with BASEEFA requirements

for BS5501: Parts 1 and 5 Ex’dCENELEC EN50 – D18, Group II B

D3W*****F Solenoid Electrical Characteristics‡

Solenoid Nominal In Rush HoldingCode Volts/Hz Amps Amps Watts

KF 12 VDC — 3.00 18

JF 24 VDC — 0.75 18

‡ Based on nominal voltage @ 22°C (72°F)

Explosion Proof Solenoids

Technical Information Series D3W

D3W Rectified AC Solenoid ElectricalCharacteristics‡

Solenoid Nominal In Rush HoldingCode Volts/Hz Amps Amps Watts

Y 120/60 — .37 36110/50

T 240/60 — .18 36220/50

YF 120/60 — .18 18110/50

TF 240/60 — .09 18220/50

‡ Based on nominal voltage @ 22°C (72°F)

Page 11: DocumentD3

Hydraulics A54

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A

Dimensions Series D3W

Hirschmann, Double AC Solenoid

Inch equivalents for millimeter dimensions are shown in (**)

Hirschmann, Single AC Solenoid

THIRD-ANGLEPROJECTION

THIRD-ANGLEPROJECTION

58.0 (2.29)

23.0 (.91)

12.0 (.47)

36.0 (1.42)

86.2 (3.40)

90.0 (3.54)

107.7 (4.24)

89.8 (3.54)

69.5 (2.74)

21.5 (.85)

74.5 (2.93)

97.8 (3.85)

152.5 (6.01)

129.1 (5.09)

76.2 (3.00)

27.3 (1.08)

58.0 (2.29)

23.0 (.91)

12.0 (.47)

36.0 (1.42)

86.2 (3.40)

90.0 (3.54)

107.7 (4.24)

89.8 (3.54)

69.5 (2.74)

21.5 (.85)

74.5 (2.93)

97.8 (3.85)

27.3 (1.08)

76.2 (3.00)

87.9 (3.45)

SeeNote

Note: 30.0mm (1.18") from bottom of bolt counterbore.

Page 12: DocumentD3

Hydraulics A55

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Conduit Cavity, Double DC Solenoid

Inch equivalents for millimeter dimensions are shown in (**)

Dimensions Series D3W

Conduit Cavity, Single DC Solenoid

THIRD-ANGLEPROJECTION

THIRD-ANGLEPROJECTION

177.2 (6.98)

76.2 (3.00)

27.3 (1.08)

122.5 (4.83)

21.5 (.85)

69.5 (2.74)

90.0 (3.54)

86.2 (3.40)

36.0 (1.42)

12.0 (.47)

23.0 (.91)

58.0 (2.29)

87.9 (3.46)

76.2 (3.00)

27.3 (1.08)

122.5 (4.83)

21.5 (.85)

69.5 (2.74)

90.0 (3.54)

86.2 (3.40)

36.0 (1.42)

12.0 (.47)

23.0 (.91)

58.0 (2.29)

Page 13: DocumentD3

Hydraulics A56

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A Conduit Box Extension, Double AC Solenoidwith Variation 6 (Manaplug) & Variation P (Extended Manual Override)

Inch equivalents for millimeter dimensions are shown in (**)

Dimensions Series D3W

Conduit Box Extension, Double DC Solenoidwith Variation 6 (Manaplug) & Variation P (Extended Manual Override)

THIRD-ANGLEPROJECTION

THIRD-ANGLEPROJECTION

15.9 (.63)

112.2 (4.42)97.8 (3.85)

21.5 (.85)

166.9 (6.58)152.5 (6.01)

76.2 (3.00)74.1 (2.92)

27.3 (1.08)

69.5 (2.74)

128.6 (5.07)

103.1 (4.06)

36.0 (1.42)

58.0 (2.29)

23.0 (.91)

12.0 (.47)

15.9 (.63)

21.5 (.85)

76.2 (3.00)

27.3 (1.08)

58.0 (2.29)

23.0 (.91)

12.0 (.47)

36.0 (1.42)

103.1 (4.06)

128.6 (5.07)

69.5 (2.74)

195.0 (7.68)

140.4 (5.53)

Page 14: DocumentD3

Hydraulics A57

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Explosion Proof U.L. & CSA, Double Solenoid

Inch equivalents for millimeter dimensions are shown in (**)

Dimensions Series D3W

Explosion Proof CENELEC, Double Solenoid

THIRD-ANGLEPROJECTION

THIRD-ANGLEPROJECTION

BoltholeCenterlineReference

#18 AWG, 18 Inches Long, No Terminals,with UL Approval and Markings

98.0(3.86)

11.7(0.46)

36.0(1.42)

58.0(2.29)

23.0(0.91) 12.0

(0.47)

BoltholeCenterlineReference

18.9(0.74)

18.9 (0.74) Ref.

143.7(5.66)

197.3 (7.77)

23.0(0.91)

63.6(2.51)

11.3 (0.44)64.9 (2.56)

76.9 (3.03)117.2 (4.62)

1/2 Inch NPT

BoltholeCenterlineReference

M20 x 1.5-6H Metric Thread

134.7(5.31)

103.6(4.08)

36.0(1.42)

18.9 (0.74) Ref.

11.6(0.46)

18.9(0.74)

12.1(0.47)

BoltholeCenterlineReference

23.0(0.91)

58.1(2.29) 154.1

(6.07)

23.0(0.91)

75.6 (2.98)207.7(8.18)

11.3(0.44)

64.9 (2.56)

76.7 (3.02)

Page 15: DocumentD3

Hydraulics A58

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A Conduit Box, Single DC Solenoidwith Variation I7 (Monitor Switch)

Inch equivalents for millimeter dimensions are shown in (**)

Dimensions Series D3W

58.0 (2.29)

23.0 (.91)

12.0 (.47)

36.0 (1.42)

86.2 (3.40)

90.0 (3.54)

122.5 (4.83)

21.5 (.85)

176.2 (6.94)

76.2 (3.00)

27.3 (1.08)

69.5 (2.74)85.3 (3.36)

For repetitive switch power-up conditions, please consultfactory.

Monitor Switch(Variation I7)

This feature provides for electrical confirmation of thespool shift. This can be used in safety circuits, toassure proper sequencing, etc.

Switch Data

Inductive switch requiring +18-42 volt input. OutputsA and B are opposite; one at “0” voltage, the other atinput voltage. During switching, A and B outputsreverse. Provides 0.4A switching current.

BLOCK DIAGRAM

Inductor

Regulator

(Extended Position)

Pin 2 (Input 24VDC)

Pin 1 (Output N.O.)

Pin 3 (Output N.C.)

Pin 4 (Ground Terminal)

Page 16: DocumentD3

Hydraulics A59

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Accessories Series D3W

Conduit Box(connection option K)

Interface – 152.4 cm (6.0 inch) lead wires, 18 awg.

– NEMA 4 rating available (consult factory)

– Waterproof

Manaplug

(valve variations 6, 56, 1A, 1C)

Interface – Brad Harrison Plug

– 3-Pin for Single Solenoid

– 5-Pin for Double Solenoid

Solenoid (Positive)Wire #2 (Red/White)

GroundWire #1 (Green)

Solenoid (Negative)Wire #3 (Red/Black)

3-Pin Manaplug (Mini) with LightsSingle Solenoid Valves

"B” Solenoid (Positive)Wire #1 (Red/White)

"A” Solenoid (Positive)Wire #2 (Red)

"B” Solenoid (Negative)Wire #5 (Red/Black)

"A” Solenoid (Negative)Wire #4 (Red/Yellow)

GroundWire #3 (Green)

5-Pin Manaplug (Mini) with LightsSingle and Double Solenoid Valves

("A" and "B" Solenoids Reversed for #8 and #9 Spools)

Pin #2(Negative)

Pin #3(Ground)

Pin #1(Positive)

Hirschmann Plug with Lights

Face View of Plug

Page 17: DocumentD3

Hydraulics A60

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

AD 3 W

NFPA D05CETOP 5

NG 10

Wet armaturesolenoid

Code Description

N Nitrile

V Fluorocarbon

Code Description

E # 24/60 - 24/50 VAC

Y 120/60 - 110/50 VAC

T 240/60 - 220/50 VAC

K 12 VDC

J 24 VDC

D # 120 VDC

# High Watt Coil only.

Code Description

Single solenoid, 2 position, B * spring offset

P to A and B to T in offset position

C Double solenoid, 3 position,spring centered.

D † Double solenoid, 2 position, detent

Single solenoid, 2 position,E spring centered.

P to B and A to T when energized.

Single solenoid, 2 position. Spring offset,F energized to center. Position spool spacer on A

side. P to A and B to T in spring offset position.

Single solenoid, 2 position,H * spring offset.

P to B and A to T in offset position.

Single solenoid, 2 position.K Spring centered.

A side. P to A and B to T when energized.

Single solenoid, 2 position, spring offset, energizedM to center position. Spool spacer on B side. P to B

and A to T in spring offset position.

* Only spools 20, 26 & 30.† Only spools 20 & 30.

A B

P T

b

A B

P T

b a

A B

P T

b

A B

P T

b

A B

P T

b a

A B

P T

a

A B

P T

a

A B

P T

a

This condition varieswith spool code

SolenoidVoltage

ActuatorBasicValve

DirectionalControl Valve

Spool Style Seal

Ordering Information Series D3W

Valve schematic symbols are per NFPA/ANSIstandards, providing flow P to A when energizingsolenoid A. Note operators reverse sides for #8 and#9 spools. See installation information for details.

Code Symbol Code Symbol

1 14

2 15

3 16

4 20*

5 21†

6 22†

7 26*†

8*, 9** 30**

10† 81†

11 82†

12

* 8, 20 & 26 spool have closed crossover** 9 & 30 spool have open crossover† Available only with high-watt rectified AC coils or

high-watt DC coils

A B

P T

A B

P TA B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

Page 18: DocumentD3

Hydraulics A61

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Code Description

C Conduit Cavity

K Conduit Adaptor

P† Hirschmann w/Plug

W* Hirschmann w/o Plug

S*†# Double Spade

E Explosion Proof

* Available only with J, K,Y (rectified) and T (rectified)voltages.

†Not CSA approved.#DC voltage only.

Code Coil

Omit High Watt

D† Explosion Proof, EExd

F* Low Watt

U Explosion Proof, UL/CSA

* Available only with J, K, Y (Rectified)and T (Rectified) voltages.

† Explosion proof coils are 60 Hz atstandard voltage; dual rating notavailable.

Code Description

Omit No Option

V# Varistor SurgeSuppressor

Z AC Rectified

# DC voltage only.

NOTE:Not

requiredwhen

ordering.

Valve Weight:

Single Solenoid:AC 4.3 kg (9.5 lbs)DC 5.3 kg (11.6 lbs)

Double Solenoid:AC 5.0 kg (11.0 lbs)DC 7.3 kg (16.0 lbs)

Standard Bolt Kit:

BK98

ElectricalOptions

ShiftResponse

andIndication

ConnectorPackage

SolenoidOptions

TubeOptions

ManualOverrideOptions

DesignSeries

Approvals

Code Description

Omit Low Pressure

Variations

Ordering Information Series D3W

Code Description

Omit Standard Valve

4 CSA Approval

K UL Recognition

Code Description

Omit Standard Valve

S4 Soft Shift, 0.040" Orifice

S7 Soft Shift, 0.070" Orifice

I7 Monitor Switch*

* Single solenoid models only. NotCE or CSA approved.

Code Description

Omit Standard Valve

5 Signal Lights

6 Manaplug, Brad Harrison Mini

7 Manaplug, Brad Harrison Micro (M12x1)

56 Manaplug (Mini) with Lights

57 Manaplug (Micro) with Lights (M12x1)

1A Manaplug (Mini) Single Sol. 5-Pin

1B Manaplug (Micro) Single Sol. 5-Pin (M12x1)

1C Manaplug (Mini) Single Sol. 5-Pin w/Lights

1D Manaplug (Micro) Single Sol. 5-Pin w/Lights (M12x1)

Code Description

Omit Standard Tube

P Extended Manual Override

R Repairable Manual Override

Mounting Bolt KitsUNC Bolt Kits for use with D3W

Directional Control Valves & Manapak/Cartpak

Number of Manapaks/Cartpaks@ 2.00" (50mm) thickness

0 1 2 3

D3W BK98 BK141 BK142 BK1431.62" 3.50" 5.50" 7.50"

D3W with BK144 BK61 BK62 BK63explosion proof 2.37" 4.25" 6.25" 8.25"coils

NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to16 Nm (12 ft-lbs)

Page 19: DocumentD3

Hydraulics A62

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A

Ordering Information Series D3W

Manaplugs – Electrical Plug (Mini)

Hirschmann – Female Connector

Electrical Cords (Mini)

E P 3

D05 Pattern

Electrical

Code Description

3 3-Pin Plug

5 5-Pin Plug

E P H

Code Description

A Gray (Solenoid A)

B Black (Solenoid B)

E C

Code Description

Omit 6 feet (std)

3 3 feet

12 12 feet

Code Description

Omit 3 Conductors (std)

5 5 Conductors

Plug ValveModel

BasicConfigurations

Electrical Lights

Code Description

E 24/60 - 24/50 VAC

Y 120/60 - 110/50 VAC

T 240/60 - 220/50 VAC

K 12 VDC

J 24 VDC

D 120 VDC

Electrical Plug HirschmannStyle

ConnectorColor

Electrical Cord No. ofConductors

ElectricalRequirements

EL32

VoltageElectricalLight

Code Description

EP 24/60 - 24/50 VAC

YP 120/60 - 110/50 VAC

TP 240/60 - 220/50 VAC

KP 12 VDC

JP 24 VDC

DP 120 VDC

ELHI

VoltageElectricalLight

ConduitBoxStyle

HirschmannStyle(One light req'dper solenoid)

Page 20: DocumentD3

Hydraulics A63

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Interface NFPA D05, CETOP 5, NG 10

Max. Operating P, A, B:Pressure 345 Bar (5000 PSI) Standard

CSA 207 Bar (3000 PSI)

Tank:103 Bar (1500 PSI) Standard207 Bar (3000 PSI) Optional

CSA 103 Bar (1500 PSI)

Specifications

General Description

The D3DW Series directional control valves are high-performance, 5-chamber, direct operated, wet arma-ture solenoid controlled, 3 or 4-way valves. They areavailable in 2 or 3-position and conform to NFPA’sD05/CETOP 5 mounting patterns.

Features

• 22 spools available including proportional.

• Repairable manual override for easy seal replacement.

• DC surge suppression available to protect electricalequipment.

• Easy access mounting bolts.

• CSA approved.

• No tools required for coil removal.

• High pressure tank line capability.

Response Time (ms)Signal to 95% spool stroke measured at175 Bar (2500 PSI) and 75 L/M (20 GPM)

Solenoid Type Pull-In Drop-Out

DC 110 85

Technical Information Series D3DW

AA BB

P T

Solenoid Ratings**

Insulation Class HAllowable Deviationfrom rated voltage -10% to +15%Armature Wet pin type

** DC Solenoids available with optional molded metal oxide varistor(MOV) for surge suppression.

Leadwire length 6” from coil face.

D3W Solenoid Electrical Characteristics

Solenoid Nominal In Rush Holding NominalCode Volts Amps Amps Watts (Ref)

K 12 VDC — 3.00 36

J 24 VDC — 1.50 36

D 120 VDC — 0.30 36

Page 21: DocumentD3

Hydraulics A64

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A Hirschmann, Double DC Solenoid

Inch equivalents for millimeter dimensions are shown in (**)

Hirschmann, Single DC Solenoid

THIRD-ANGLEPROJECTION

THIRD-ANGLEPROJECTION

177.2 (6.98)

76.2 (3.00)

122.5 (4.83)

80.1 (3.16)

21.5 (0.85)

58.9 (2.29)

23.0 (0.91)

12.0 (0.47)

36.0 (1.42)

83.0 (3.27)106.2 (4.18)

87.8 (3.46)

87.9 (3.46)

76.2 (3.00)

21.5 (0.85)

40.5 (1.60)

122.5 (4.83)

88.2 (3.48)83.0 (3.27)

36.0 (1.42)

12.0 (0.47)

23.0 (0.91)

58.0 (2.29)

SeeNote

Dimensions Series D3DW

Note: 30.0mm (1.18") from bottom of bolt counterbore.

Page 22: DocumentD3

Hydraulics A65

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Dual Spade, Single DC Solenoidwith Variation I7 (Monitor Switch)

Inch equivalents for millimeter dimensions are shown in (**)

85.3 (3.36)

21.5 (0.85)

40.5 (1.60) 76.2 (3.00)

122.5 (4.83) 176.2 (6.94)

88.2 (3.48)

96.1 (3.79)

83.0 (3.27)

36.0 (1.42)

12.0 (0.47)

23.0 (0.91)

58.0 (2.29)

For repetitive switch power-up conditions, please consultfactory.

Monitor Switch(Variation I7)

This feature provides for electrical confirmation of thespool shift. This can be used in safety circuits, toassure proper sequencing, etc.

Switch Data

Inductive switch requiring +18-42 volt input. OutputsA and B are opposite; one at “0” voltage, the other atinput voltage. During switching, A and B outputsreverse. Provides 0.4A switching current.

BLOCK DIAGRAM

Inductor

Regulator

(Extended Position)

Pin 2 (Input 24VDC)

Pin 1 (Output N.O.)

Pin 3 (Output N.C.)

Pin 4 (Ground Terminal)

Dimensions Series D3DW

Page 23: DocumentD3

Hydraulics A66

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

AD 3 D W

NFPA D05CETOP 5

NG 10

Wet armaturesolenoid

Code Description

N Nitrile

V Fluorocarbon

Code Description

K 12 VDC

J 24 VDC

D 120 VDC

Code Description

Single solenoid, 2 position, B * spring offset

P to A and B to T in offset position

C Double solenoid, 3 position,spring centered.

D † Double solenoid, 2 position, detent

Single solenoid, 2 position,E spring centered.

P to B and A to T when energized.

Single solenoid, 2 position. Spring offset,F energized to center. Position spool spacer on A

side. P to A and B to T in spring offset position.

Single solenoid, 2 position,H * spring offset.

P to B and A to T in offset position.

Single solenoid, 2 position.K Spring centered.

A side. P to A and B to T when energized.

Single solenoid, 2 position, spring offset, energizedM to center position. Spool spacer on B side. P to B

and A to T in spring offset position.

* Only spools 20, 26 & 30.† Only spools 20 & 30.

Code Symbol Code Symbol

1 14

2 15

3 16

4 20*

5 21

6 22

7 26*

8*, 9** 30**

10 81

11 82

12

* 8, 20 & 26 spool have closed crossover** 9 & 30 spool have open crossover

A B

P T

A B

P TA B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

b

A B

P T

b a

A B

P T

b

A B

P T

b

A B

P T

b a

A B

P T

a

A B

P T

a

A B

P T

a

A B

P T

This condition varieswith spool code

SolenoidVoltage

ActuatorBasicValve

DirectionalControl Valve

Spool Style SealBody

5-ChamberBody

Ordering Information Series D3DW

A B

P T

Valve schematic symbols are per NFPA/ANSIstandards, providing flow P to A when energizingsolenoid A. Note operators reverse sides for #8 and#9 spools. See installation information for details.

Page 24: DocumentD3

Hydraulics A67

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Code Description

P† Hirschmann w/Plug

W* Hirschmann w/o Plug

S*† Double Spade

* Not available with signal lights.† Not CSA approved.

Code Description

Omit Standard Tube

P Extended Manual Override

R Repairable Manual Override

Code Description

Omit No Option

NOTE:Not

requiredwhen

ordering.

Valve Weight:

Single Solenoid5.3 kg (11.6 lbs)

Double Solenoid7.3 kg (16.0 lbs)

Standard Bolt Kit:

BK98

ElectricalOptions

ShiftIndication

ConnectorPackage

SolenoidOptions

TubeOptions

ManualOverrideOptions

DesignSeries

Approvals

Code Description

Omit Low Pressure

H High Pressure

Variations

Ordering Information Series D3DW

Mounting Bolt KitsUNC Bolt Kits for use with D3DW

Directional Control Valves & Manapak/Cartpak

Number of Manapaks/Cartpaks@ 2.00" (50mm) thickness

0 1 2 3

D3DW BK98 BK141 BK142 BK1431.62" 3.50" 5.50" 7.50"

D3DW with BK144 BK61 BK62 BK63explosion proof 2.37" 4.25" 6.25" 8.25"coils

NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to16 Nm (12 ft-lbs)

Code Coil

Omit High Watt

Code Description

Omit Standard Valve

I7* Monitor Switch

* Single solenoid models only.Not CE or CSA approved.

Code Description

Omit Standard Valve

4* CSA Approval

K UL Recognition

* Not available with highpressure tube.

Code Description

Omit Standard Valve

5 Signal Lights

Page 25: DocumentD3

Hydraulics A68

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

AGeneral Description

The D3L Series directional control valves are high-performance, 4-chamber, direct operated, levercontrolled, 3 or 4-way valves. They are available in 2or 3-position and conform to NFPA’s D05/CETOP 5mounting patterns.

Features• Spring return or detent styles available

• High flow, low pressure drop design

• Heavy duty handle design

Specifications

Mounting Pattern NFPA D05, CETOP 5, NG 10Maximum Operating: 345 Bar (5000 PSI)Pressure Tank Line: 34 Bar (500 PSI)Maximum Flow See Quick Reference ChartForce Requiredto Shift Lever 173 N (39 lbs)Operator

Dimensions

Inch equivalents for millimeter dimensions are shown in (**)

Lever Operated D3L

A B

P T

Technical Information Series D3L

THIRD-ANGLEPROJECTION

8.9°Full Shift

149.07 (5.873)

162.81 (6.415)

58.23 (2.294)

174.45 (6.873)

15.50 (0.611)

89.95 (3.544)

36.00 (1.418)

35.00 (1.379)

70.00 (2.758)

See Note

Note: 30.0mm (1.18") from bottom of bolt counterbore.

Page 26: DocumentD3

Hydraulics A69

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

D 3

NFPA D05CETOP 5

NG10

Code Description

N Nitrile

V Fluorocarbon

Operator Location (A or B End)Code Operator Type For Valve Style

B C D E H K N

L Lever (Standard) B B B A B B B

LB Lever (Alternate) A A A N/A A N/A A

Not RequiredWhen Ordering

Code Description

Omit Standard

I7* Monitor Switch

* Not available on C, D or NStyles.Not CE or CSA approved.

Code Symbol Code Symbol

1 20*

2 30†

4 81

8* 82

9†

* 8 and 20 spools have closed crossover.† 9 and 30 are open crossover.

Code Description

Two position, spring offset.B* P to A and B to T in offset

position.

C Three position,spring centered.

D* Two position, detent.

Two position, spring centered.E P to B and A to T

in shifted position.

Two position, spring offset.H* P to B and A to T

in offset position.

Two position, spring centered.K P to A and B to T

in shifted position.

N Three position, detent.

* 20 and 30 spools only.

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

This condition varieswith spool code

VariationsBasicValve

DirectionalControl Valve

Spool Style SealCompound

OperatorType & Location

DesignSeries

Ordering Information Series D3L

A B

P T

A B

P T

Mounting Bolt KitsUNC Bolt Kits for use with D3L Valves

Directional Control Valves & Manapak/Cartpak

Number of Manapaks/Cartpaks@ 2.00" (50mm) thickness

0 1 2 3

D3L BK98 BK141 BK142 BK1431.62" 3.62" 5.62" 7.62"

NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to16 Nm (12 ft-lbs)

Valve schematic symbols are per NFPA/ANSI standards, providingflow P to A when energizing operator A. Note operators reversesides for #8 and #9 spools. See installation information for details.

Valve Weight:

3.6 kg (8 lbs)

Standard Bolt Kit:

BK98

Page 27: DocumentD3

Hydraulics A70

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

AGeneral Description

The D3A Series directional control valves are high-performance, 4-chamber, direct operated, air pilotcontrolled, 3 or 4-way valves. They are available in 2or 3-position and conform to NFPA’s D05/CETOP 5mounting patterns.

Features

• Low pilot pressure required – 3.4 Bar (50 PSI) minimum

• Manual overrides standard

• High flow, low pressure drop design

Specifications

Mounting Pattern NFPA D05, CETOP 5, NG 10Operating: 345 Bar (5000 PSI)MaximumTank Line: 34 Bar (500 PSI)Pressure

Maximum Flow See Quick Reference ChartPilot Pressure Air Minimum 3.4 Bar (50 PSI)

Air Maximum 6.9 Bar (100 PSI)

Air OperatedShift Volume. The air pilot chamber requires a volume of 1.8cc (.106 in.3) for complete shift from center to end.

Pilot Piston. The pilot piston area is 506 mm2 (.785 in.2).Pilot piston stroke is 3.4 mm (.135 in.).

AA BB

P T

Technical Information Series D3A

Response Time* (ms)Signal to 95% spool stroke measured at 172 Bar(2500 PSI) and 160 LPM (20 GPM)

Pilot Pressure Pull-In Drop-Out

50 PSI 23.0 23.0100 PSI 19.0 38.0

* Chart is for reference only. Response time will vary with pilotline size, length, air pressure and air valve flow capacity (Cv).

Page 28: DocumentD3

Hydraulics A71

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

DimensionsInch equivalents for millimeter dimensions are shown in (**)

Air Operated, Double Pilot

Air Operated, Single Pilot

Technical Information Series D3A

181.82 (7.164)

89.95 (3.544)

36.00 (1.418)

70.00 (2.758)

35.00 (1.379)

79.51 (3.133) 101.81 (4.011)

See Note

THIRD-ANGLEPROJECTION

THIRD-ANGLEPROJECTION

214.0 (8.43)

90.0 (3.55)

36.0 (1.42)

35.0(1.38)

70.0 (2.76)

67.1 (2.64)134.3 (5.29)

121.1 (4.77)

Note: 30.0mm (1.18") from bottom of bolt counterbore.

Page 29: DocumentD3

Hydraulics A72

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A

Ordering Information Series D3A

D 3 A

NFPA D05CETOP 5

NG 10

Code Description

N Nitrile

V Fluorocarbon

Not RequiredWhen Ordering

Code Description

Omit Standard

I7* Monitor Switch

* Available in B, E, H & Kstyles only.Not CE or CSA approved.

Code Description

Single operator, two positionB # spring offset.

P to A and B to T in offset position.

Double operator,C three position,

spring centered.

Double operator,D # two position,

detent.

Two position, spring centered.E P to B and A to T

in shifted position.

Single operator, two position,H # spring offset. P to B and A to T

in offset position.

Two position, spring centered.K P to A and B to T

in shifted position.

# B, D & H styles available with 20 and 30 spools only.

Code Description

A Air Operator

Indicates air pilot

This condition varieswith spool code

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A

VariationsBasicValve

DirectionalControl Valve

Spool Style SealCompound

Actuator DesignSeries

Code Symbol Code Symbol

1 20*

2 30†

4 81

8* 82

9†

* 8 and 20 spools have closed crossover.† 9 and 30 are open crossover.

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

A B

P T

Mounting Bolt KitsUNC Bolt Kits for use with D3A Valves

Directional Control Valves & Manapak/Cartpak

Number of Manapaks/Cartpaks@ 2.00" (50mm) thickness

0 1 2 3

D3A BK98 BK141 BK142 BK1431.62" 3.62" 5.62" 7.62"

NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to16 Nm (12 ft-lbs)

Valve schematic symbols are per NFPA/ANSI standards, providingflow P to A when energizing operator A. Note operators reversesides for #8 and #9 spools. See installation information for details.

Valve Weight:

4.1 kg (9 lbs)

Standard Bolt Kit:

BK98

Page 30: DocumentD3

Hydraulics A73

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Technical Information Series D3C and D3D

General DescriptionThe D3C and D3D Series directional control valves arehigh-performance, 4-chamber, direct operated, camcontrolled, 3 or 4-way valves. They are available in 2-position and conform to NFPA’s D05/CETOP 5 mountingpatterns.

Features• Choice of 2 cam roller positions (D3C and D3D)

• Short stroke option

• High flow, low pressure drop design

Specifications

Mounting Pattern NFPA D05, CETOP 5, NG 10Maximum Operating: 345 Bar (5000 PSI)Pressure Tank Line: 34 Bar (500 PSI)Maximum Flow See Quick Reference ChartForce Required 107 N (53 lbs.)to ShiftMaximumCam Angle 30°

DimensionsInch equivalents for millimeter dimensions are shown in (**)

Cam Operated

FullValve Type Pre-Travel Spool Over-Travel

Travel

Standard 1.75 5.75 2.03Valve (0.07) (0.23) (0.08)

B5 0 4.00 2.03Short Stroke (0) (0.16) (0.08)

Over-TravelFull Spool Travel

Pre-Travel

87.3 (3.44)

36.0 (1.42)

23.12 (0.91)79.3 (3.13)

88.8 (3.50)

190.7 (7.51)

12.0 (0.47)

70.0 (2.76)

35.0 (1.38)

See Note

Note: 30.0mm (1.18") from bottom of bolt counterbore.

Page 31: DocumentD3

Hydraulics A74

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control ValvesCatalog 2502/USA

A

Ordering Information Series D3C and D3D

D 3

NFPA D05CETOP 5

NG 10

Code Description

N Nitrile

V Fluorocarbon

Not RequiredWhen Ordering

Code Description

Omit Standard

B5 Short Stroke

I7* Monitor Switch

* Not CE or CSA approved.

Code Symbol

20*

30†

* 20 spool has closedcrossover.

† 30 spool has opencrossover.

Code Description

Two position,B spring offset operator

at “A” port end.

Two position,H spring offset operator

at “B” port end.

Code Description

C Cam (90° tomounting surface)

D Cam parallel tomounting surface

A B

P T

A B

P T

VariationsBasicValve

DirectionalControl Valve

Spool Style SealCompound

Actuator DesignSeries

A B

P T

A B

P T

Mounting Bolt KitsUNC Bolt Kits for use with D3C & D3D ValvesDirectional Control Valves & Manapak/Cartpak

Number of Manapaks/Cartpaks@ 2.00" (50mm) thickness

0 1 2 3

D3C, D3D BK98 BK141 BK142 BK1431.62" 3.62" 5.62" 7.62"

NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to16 Nm (12 ft-lbs)

Valve Weight:

3.6 kg (8 lbs)

Standard Bolt Kit:

BK98

Valve schematic symbols are per NFPA/ANSIstandards, providing flow P to A when energized.Note operators reverse sides for #8 and #9 spools.See installation information for details.

Page 32: DocumentD3

Hydraulics A75

Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA

Directional Control Valves

A

Catalog 2502/USA

Installation Information Series D3*

Fluid RecommendationsPremium quality hydraulic oil with a viscosity rangebetween 150-250 SSU (32 -54 cst) at 38° C (100°F) isrecommended. The absolute operation viscosity range isfrom 80-1000 SSU (16-220 cst). Oil should havemaximum anti-wear properties and rust and oxidationtreatments.

Fluids and SealsValves using synthetic, fire-resistant fluids requirespecial seals. When phospate ester or its blends areused, FLUOROCARBON seals are required. Water-glycol, water-in-oil emulsions, and petroleum oil may beused with NITRILE seals.

Temperature RecommendationRecommended oil temperature:-7° to +71°C (-20 to +160°F)

FiltrationFor maximum valve and system component life, thesystem should be protected at a contamination level notto exceed 125 particles greater than 10 microns permilliliter of fluid. (SAE Class 4 or better, ISO Code16/13).

Tank Line SurgesIf several valves are piped with a common tank line, flowsurges in the line may cause unexpected spool shift.Detent style valves are most susceptible to this.Separate tank lines should be used when line surges areexpected in an application.

Recommended Mounting Position

Valve Type Recommended Mounting Position

Detent (Solenoid) HorizontalSpring Offset UnrestrictedSpring Centered Unrestricted

SiltingSilting can cause any sliding spool valve to stick and notspring return, if held shifted under pressure for longperiods of time. The valve should be cycled periodicallyto prevent sticking.

Single Pass OperationValve flow ratings are for double pass operation(with equal flow in both paths). When using thesecomponents in single pass applications, flow capabilitiesmay be reduced. Consult your local Parkerrepresentative for details.

Flow Path Data

*Note: On valves with 8 or 9 spool, A and/or B operators reversesides. Flow paths remain the same as viewed from top ofvalve.

Double Solenoid. With solenoid “A” energized, flowpath is P→A and B→T. When solenoid “B” is energized,flow path is P→B and A→T. The center condition on aspring-centered valve exists when both coils are de-energized, or during a complete shift, as the spoolpasses through center.

Detent and Spring Offset. The center condition existson detent and spring offset valves only during spoolcrossover. To shift and hold a detented spool, only amomentary energizing of the solenoid is necessary. Theminimum duration of the signal is aproximately 0.13seconds for both AC and DC voltages. This position willbe held provided the spool center line is in a horizontalplane, and no shock or vibration is present to displacethe spool.

Single Solenoid. Spring offset valves can be ordered insix styles: B, E, F, H, K and M. Flow path data for thevarious styles are described in the order chart.

Lever Operated (on B end)Pull lever away from valve P→A; B→TPush lever toward valve P→B; A→T

Note: Reverse with a #8 or #9 spool.

Electrical FailureShould electric power fail, spring offset and springcentered valves will shift to the spring held position.Detented valves will stay in the last position held beforepower failure. If main flow does not fail or stopsimultaneously, machine actuators may continue tofunction in an undesirable manner or sequence.

Loss of Pilot Pressure (D3A)Should a loss of pilot pressure occur, spring offset andspring centered valves will shift to the spring heldposition. Detented valves will remain in the last positionheld. If main hydraulic flow does not simultaneouslystop, machine actuators may continue to function in anundesirable manner or sequence.

Torque SpecificationsTorque values recommended for the bolts which mountthe valve to the manifold or subplate are as follows:

1/4-20 thread (M6x1) torque 16.0 Nm (12 ft-lbs).

D3*

Operator B Operator A

P

A B

TT