Perma Pure LLC Custom Dilution Probe for Increased CEMS Accuracy EUEC Conference B8.6 February 3, 2010 Scott D. Brown

Custom Dilution Probe

Embed Size (px)

Citation preview

Page 1: Custom Dilution Probe

Perma Pure, 2009 Page 1

Perma Pure LLC

Custom Dilution Probefor Increased

CEMS Accuracy

EUEC Conference B8.6

February 3, 2010

Scott D. Brown

Page 2: Custom Dilution Probe

© Perma Pure, 2010 Page 2

Sample Handling – Critical Path for CEMS

Perma Pure Systems

PROBE CONDITIONING SYSTEM ANALYZERS DATA AQUISITION

CO2

NOX

SO2

Page 3: Custom Dilution Probe

© Perma Pure, 2010 Page 3

Perma Pure – Gas Sample Handling

3 Technologies:• Dilution Probes

– Wet measurement

• Baldwin™ brand Thermoelectric Coolers– Water removal through flash condensation

• Nafion® permeation dryers and systems– Water removal in vapor phase at the stack through unique

membrane dryer (ion exchange) technology

• Plus extractive probes, filters, scrubbers, accessories

Page 4: Custom Dilution Probe

The Facility

Intermountain Power Service Corporation (IPSC)

Twin 950 MWcoal-fired steamelectric generators

Delta, UT

© Perma Pure, 2010 Page 4

Page 5: Custom Dilution Probe

The Opportunity

© Perma Pure, 2010 Page 5

• Help IPSC achieve more accurate CEMS reporting of CO2. 16 million tons/year; a couple % adds up.

• Working with RMB Consulting and software provider Cartwright Associates, IPSC had developed an algorithm to compensate for high CO2 bias.

• The algorithm required precise pressure and temperature measurements at the point of dilution, i.e. the critical orifice.

• IPSC desired a total of 3 pressure and 9 temperature measurements in each of 4 probes (2 inlet, 2 outlet).

Page 6: Custom Dilution Probe

The Design Challenges

• Temperature measurements would not be too difficult• Could we design pressure ports near the critical orifice,

on either side, without altering the flow path?• Could we isolate the upstream pressure port during

blowback?• Could we stabilize temperature and pressure to ensure

a stable dilution ratio and thus stable readings?• How would we accommodate all the addition wiring?

© Perma Pure, 2010 Page 6

Page 7: Custom Dilution Probe

Oh, By the Way

• Could we finalize the design and build 4 custom probes for installation 2300 miles away scheduled in less than 5 weeks?

© Perma Pure, 2010 Page 7

Page 8: Custom Dilution Probe

Baldwin™ Model 45 Dilution Probe

© Perma Pure, 2010 Page 8

Ex-Situ

Page 9: Custom Dilution Probe

Model 45 Interior

© Perma Pure, 2010 Page 9

Page 10: Custom Dilution Probe

Monel Critical Orifice – Flow Path

© Perma Pure, 2010 Page 10

Page 11: Custom Dilution Probe

Pressure Measurements

1. Critical Orifice Upstream Pressure Transmitter Port– To verify gas density

– At critical (sonic), speed is constant, but volumetric flow is not

2. Critical Orifice Downstream Vacuum Transmitter Port– To verify that flow is maintained at critical

3. Dilution Air Pressure Transmitter– Installed just after regulator, to ensure stable pressure

© Perma Pure, 2010 Page 11

Page 12: Custom Dilution Probe

Temperature Measurements

1. Critical Orifice, Upstream

2. Dilution Air Inlet

3. Stack

4. Calibration Gas Inlet

5. Blowback/Purge Inlet

6. Filter Body Housing (Controller)

7. Enclosure Air (Controller)

8. Heated Stinger (Controller)

9. Heated Umbilical (Controller)© Perma Pure, 2010 Page 12

Page 13: Custom Dilution Probe

Dual Enclosures

Objectives:

1. Maintain 290°-300°C for Filter Housing

2. Allow Ambient Temperature for all Connections

3. Plenty of room to work

© Perma Pure, 2010 Page 13

Page 14: Custom Dilution Probe

Upper (Heated) Enclosure

© Perma Pure, 2010 Page 14

Heated Backplate

Blowback Tank – controlled by IPSC PLC

Page 15: Custom Dilution Probe

Heat Exchangers (Upper Enclosure)

Objective: Maintain Stable Temperatures

1. Dilution Air HE (aluminum)

2. Cal Gas HE (SS)

3. Blowback Air HE (aluminum)

© Perma Pure, 2010 Page 15

Page 16: Custom Dilution Probe

Filter Housing/Critical Orifice Design

© Perma Pure, 2010 Page 16

Diluted Sample Out

Upstream Orifice RTD

Filter HousingCartridge Heaters

Filter Housing RTD

Dilution Air RTD

Downstream Orifice Vacuum Port

Upstream Orifice Pressure Port

Page 17: Custom Dilution Probe

Lower (Ambient) Enclosure (Installed)

© Perma Pure, 2010 Page 17

Front Panel

Dilution(Eductor) Pressure Adjustment

Temp Readings

Page 18: Custom Dilution Probe

Heated Stinger Design

Objective: Maintain Stable Sample Gas TemperatureRequirements:• 2 outlet stingers (Inlet stingers were reused)• 8 feet extension into stack, plus 10” external• C256 Hastelloy sample tube with removable PFA liner• Accessibility chamber for changing liner without

removing stinger from the stack• 316 SS shell with fiberglass insulated heat tape

(Amptek heavy AMOX insulated Duo-Tape)• Separate 2 foot probe for stack temperature© Perma Pure, 2010 Page 18

Page 19: Custom Dilution Probe

Heated Stinger

© Perma Pure, 2010 Page 19

Page 20: Custom Dilution Probe

Teflon Liner Access

© Perma Pure, 2010 Page 20

Page 21: Custom Dilution Probe

Installation

• Performed by IPSC in April, 2009

• Perma Pure provided on-site technical support

• Installation Unit 1 during Shutdown

• Installation Unit 2 during Operation

• Elapsed Time: 5 days for all 4 probes

© Perma Pure, 2010 Page 21

Page 22: Custom Dilution Probe

Installed View

© Perma Pure, 2010 Page 22

Inlet Side Outlet Side

IPSC Cabinet:•Transmitters•Digital displays•PLC

Page 23: Custom Dilution Probe

Probes Enables Greater Accuracy

• Probe designed to yield maximum stability of temperature and pressure

• Dilution ratio is not assumed to be constant. Instead, it is calculated dynamically for greater accuracy

• Plant uses dilution ratio correction algorithm to calculate true dilution ratio based on sensor outputs from probe

• IPSC now adjusts the dilution pressure to achieve an initial dilution ratio that yields precise cal gas measurement

© Perma Pure, 2010 Page 23

Page 24: Custom Dilution Probe

Calibration Routine (Quarterly if needed)

1. CO2 Analyzer set – zero & span at diluted level (≈1200ppm)

2. Run CO2 cal gas (12%) through probe and adjust eductor pressure control so the diluted sample matches cal gas tag value

3. Enter remaining parameters into software1. Sample pressure, critical orifice temp2. Set other gas constituent analyzers

4. Software correction enabled– From this point, software will make corrections as necessary

based on continuous pressure/temp/molecular weight readings

© Perma Pure, 2010 Page 24

Page 25: Custom Dilution Probe

Final Results

• Each Unit passed RATA the week after installation

• Overall ≈ 2% reduction in reported CO2 bias as a result of probe and algorithm

• Difference of ≈ 300,000 tons/year reported CO2

© Perma Pure, 2010 Page 25

Page 26: Custom Dilution Probe

© Perma Pure, 2010 Page 26