3
BEHAVIOUR WITH ATMOSPHERIC AND CHEMICAL AGENTS Agent Saline solution Acids Bases Solvents Mineral oil UV rays Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Ethyl alcohol Resistance Resistant Not resistant Limited resistance Not resistant Limited resistance Limited resistance Not resistant Not resistant Not resistant Limited resistance Limited resistance 70 RT ROTARY SWITCHES - INSULATING BOX Rotary control switch disconnectors for continuous operation, assembled in boards and watertight boxes and equipped with fixing accessories enabling use as: back-geared command on doors, locking switches on access doors to boards and emergency switches. Complying with standard EN 60947-3. Type of device Thermo-pressure with ball (°C) Glow wire test (°C) Resistance to surface currents (V) Terminal tightening capacity (mm 2 ) Impact resistance of case at ambient temperature (IK code) rigid cables flexible cables no. poles In (A) max min max min 2 - 3 - 4 16 125 (device) 80 (case) 850 (device) 650 (case) 175 (50 drops) 4 1.5 2.5 1.5 IK 08 2 - 3 - 4 32 and 40 10 1.5 6 1.5 3 - 4 63 25 2.5 16 1.5 FIELDS AND CATEGORIES OF USE Sector Environment Typical system Function Typical category of use Recommended IP rating Domestic and similar Technical areas Heating system Motor control AC 23 B IP 65 Lighting command AC 21 A General services board Command of technological services for buildings AC 22 B IP 20 Gardens and open spaces Lighting Lighting command AC 21 A IP 65 Commercial (as well as cases in the domestic sector) Warehouses Lighting Machines for maintenance and handling Lighting command AC 21 A IP 65 Motor control AC 23 A Emergency control AC 23 A Public meeting and entertainment places Shops - Cafés Showrooms Lighting Signs Audiovisuals Lighting command Stage curtain command Emergency control AC 23 B IP 65 Distribution board Technical service commands AC 22 B IP 20 Industry Warehouse Bridge crane Emergency command AC 23 B IP 65 Machine control board Motor control AC 23 B IP 65 TECHNICAL DATA AND COMPLIANCE WITH STANDARDS 16 A 32 A 40A 63 A Thermal rated current Ith in air A 16 32 40 63 Thermal rated current Ithe in case A 16 32 40 63 Rated operating voltage Ue V 400 400 400 500 Rated insulation voltage Ui (III/3) V 690 690 690 690 Rated operating voltage Ie AC-21 A A 16 32 40 63 RATED OPERATING POWER Category of use AC-3 A Caged motors: motor start/stop during rotation 3 x 400V kW 5 10 12 19 Category of use AC-23 A Manoeuvre of motors or other highly inductive loads 3 x 400V kW 7 14 18 28 Rated breaking capacity AC-23A cos Φ = 0,45 3 x 400V A 160 320 400 630 PROTECTION AGAINST SHORT-CIRCUITING Rated conditional short-circuit current with fuse kAeff 10 10 6 10 Maximum fuse current (gG) A 16 32 40 63 Brief rated current Icw (1-s-current) Aeff 500 750 750 1200 Terminal screws M3 M3 M3 M5 70 RT RANGE ROTARY SWITCHES 1 TECHNICAL INFORMATION VERSION 1.0

Ct Serie 70rt Rev01 En

  • Upload
    fraumo

  • View
    225

  • Download
    2

Embed Size (px)

DESCRIPTION

Ct Serie

Citation preview

  • BEHAVIOUR WITH ATMOSPHERIC AND CHEMICAL AGENTS

    Agent Saline solutionAcids Bases Solvents Mineral

    oilUV

    raysConcentrated Diluted Concentrated Diluted Hexane Benzol Acetone Ethyl alcohol

    Resistance Resistant Not resistantLimited

    resistanceNot

    resistantLimited

    resistanceLimited

    resistanceNot

    resistantNot

    resistantNot

    resistantLimited

    resistanceLimited

    resistance

    70 RT RoTaRy swiTches - insulaTing box

    Rotary control switch disconnectors for continuous operation, assembled in boards and watertight boxes and equipped with fixing accessories enabling use as: back-geared command on doors, locking switches on access doors to boards and emergency switches.Complying with standard EN 60947-3.

    Type of device

    Thermo-pressure with ball

    (C)

    Glow wire test (C)

    Resistance to surface currents

    (V)

    Terminal tightening capacity (mm2)

    Impact resistance of case

    at ambient temperature

    (IK code)

    rigid cables flexible cables

    no. poles In (A) max min max min2 - 3 - 4 16 125 (device)

    80 (case)850 (device)

    650 (case) 175 (50 drops)4 1.5 2.5 1.5

    IK 082 - 3 - 4 32 and 40 10 1.5 6 1.53 - 4 63 25 2.5 16 1.5

    FIELDS AND CATEGORIES OF USESector Environment Typical system Function Typical category of use Recommended IP rating

    Domestic and similar

    Technical areasHeating system

    Motor control AC 23 BIP 65

    Lighting command AC 21 A

    General services board Command of technological services for buildings AC 22 B IP 20

    Gardens and open spaces Lighting Lighting command AC 21 A IP 65

    Commercial (as well as cases in the

    domestic sector)

    WarehousesLighting

    Machines for maintenance and handling

    Lighting command AC 21 AIP 65Motor control AC 23 A

    Emergency control AC 23 A

    Public meeting and entertainment places

    Shops - CafsShowrooms

    LightingSigns

    Audiovisuals

    Lighting commandStage curtain command

    Emergency controlAC 23 B IP 65

    Distribution board Technical service commands AC 22 B IP 20

    Industry WarehouseBridge crane Emergency command AC 23 B IP 65

    Machine control board Motor control AC 23 B IP 65

    TECHNICAL DATA AND COMPLIANCE WITH STANDARDS16 A 32 A 40A 63 A

    Thermal rated current Ith in air A 16 32 40 63Thermal rated current Ithe in case A 16 32 40 63Rated operating voltage Ue V 400 400 400 500Rated insulation voltage Ui (III/3) V 690 690 690 690Rated operating voltage Ie AC-21 A A 16 32 40 63RATED OPERATING POWER Category of use AC-3 A

    Caged motors: motor start/stop during rotation

    3 x 400V kW 5 10 12 19

    Category of use AC-23 A Manoeuvre of motors or other highly inductive loads

    3 x 400V kW 7 14 18 28

    Rated breaking capacity AC-23Acos = 0,45 3 x 400V A 160 320 400 630

    PROTECTION AGAINST SHORT-CIRCUITING Rated conditional short-circuit current with fuse kAeff 10 10 6 10Maximum fuse current (gG) A 16 32 40 63Brief rated current Icw (1-s-current) Aeff 500 750 750 1200Terminal screws M3 M3 M3 M5

    70 RT RangeRotaRy switches

    1 Technical informaTion Version 1.0

  • CA

    B DE

    F A

    10

    C

    B

    Dimension Tables

    SURFACE-MOUNTING ROTARY SWITCHES IP 65

    BOARD-MOUNTING ROTARY SWITCHES: DOOR-LOCKING VERSION

    BOARD-MOUNTING ROTARY SWITCH: VERSION FOR ASSEMBLY ON DIN RAIL EN 50022

    LOCKABLE RED KNOB WITH YELLOW FLANGE FOR EMERGENCY

    50

    16 - 32 - 40A

    5

    76 116

    B

    116

    A

    63A

    C

    D

    SFOND.

    26

    33.5

    A

    L L2

    L1

    5

    Type A B C D KNOCKOUT

    16 - 32 A 114 70 71.5 100 23

    63A 170 82 96 124.5 37.5

    WITHOUT BRACKETS WITH BRACKETS

    One-way switch Supplied with L Adjustable up to L*

    L1 max length obtainable

    L2 min length obtainable ** A

    16A 145 87 (145+160) 305 (87+30) 117 70

    32A 145 87 (145+160) 305 (87+30) 117 70

    63A 177 114 (117+160) 337 (114+30) 144 82

    * Position obtainable by cutting the shaft supplied.** Position obtainable by cutting both the shaft

    supplied, and the brackets, in the points shown.

    Type A B C D E F

    16A 52 53 45 35 53 68

    32A 55 71 45 37 53 68

    63A 73 89 45 44 56 68

    Occupies 3 modules (17.5mm). Occupies 4 modules (17.5mm). Occupies 5 modules (17.5mm).

    Type A B C

    16 - 32 A 70 33.5 28.5

    63A 82 33.5 28.5

    70 RT RangeRotaRy switches

    2Technical informaTion Version 1.0

  • 70 RT RoTaRy swiTches - meTal box

    Surface-mounting rotary control switch for continuous operation, in die-cast aluminum boxes color metallic gray.Disconnector versions with In 80A.IP degree: IP65.According to EN 60947-3.

    TECHNICAL DATA AND COMPILANCE WITH STANDARD16 A 32 A 40A 63 A 80 A 100 A 125 A 160 A

    Thermal rated current Ith in air A 16 32 40 63 80 100 125 160Thermal rated current Ithe in case A 16 32 40 63 80 95 120 160Rated operating voltage Ue V 400 400 400 500 400 400 500 500Rated insulation voltage Ui (III/3) V 690 690 690 690 800 800 800 800Rated operating voltage Ie AC-21 A A 16 32 40 63 80 95 120 160RATED OPERATING POWER Category of use AC-3 A

    Caged motors: motor start/stop During rotation

    3 x 400V kW 5 10 12 19 25 29 20 50

    Category of use AC-23A Manoeuvre of motors or other highlyinductive loads

    3 x 400V kW 7 14 18 28 36 42 28 72

    Rated breaking capacity AC-23Acos = 0,45 3 x 400V A 160 320 400 630 800 950 1200 1600

    PROTECTIOON AGAINST SHORT-CIRCUITING Rated conditional short-circuit current with fuse kAeff 10 10 6 10 50 15 50 50Rotary switch 70 rt - metal box A 16 32 40 63 80 100 125 160Brief rated current icw (1-s-current) Aeff 500 750 750 1200 1500 1500 2500 4000

    Dimension Tables

    SURFACE-MOUNTING ROTARY SWITCH - IP65

    9716

    5,6

    126,7

    251,8

    171,6

    257,2

    140,6 214,8 307,2

    VERSIONS16A - 32A - 40A

    VERSIONS63A - 80A - 100A

    VERSIONS125A - 160A

    70 RT RangeRotaRy switches

    3 Technical informaTion Version 1.0