16
CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Embed Size (px)

Citation preview

Page 1: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

CSC Endcap Muon Port Card

and Muon Sorter Upgrade Status

May 2013

Page 2: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

2

MPC Upgrade Requirements

■ Be able to deliver all 18 trigger primitives from the EMU peripheral crate to the upgraded Sector Processor■ Preserve sorting capabilities of the Muon Port Card■ Preserve 3 old 1.6Gbps optical links to the existing CSCTF

Page 3: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

3

Upgrade Developments n Use existing Muon Port Card main board - TMB interface remains unchanged (2 LCTs per TMB @ 80MHz) - 3 “old” optical links are still available n Original design (2004) was based on Xilinx Virtex-E XCV600E FPGA

n New prototype (2012) is based on Xilinx Spartan-6 FPGA - Inexpensive FPGA ($280 for the fastest speed grade XC6SLX150T-3FFG900C device) - 8 embedded GTP serializers - 3.2Gbps/channel data rate - Modest power consumption

(~1A Vccint; <1A GTPs)

- Pluggable 12-channel

optical transmitter

Page 4: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

4

New Spartan-6 Mezzanine

Top Bottom

Pluggable optical transmitter

Page 5: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

5

Optical Transmitter

n SNAP12 and Avago AFBR-810 are pluggable 12-channel devicesn Both use the same 10x10 low profile circuit, but pin assignment is different (Avago is intended for higher data rate)■ uTCA SP12 uses Avago AFBR820 receiver

SNAP12 transmitter Avago AFBR-810

Page 6: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

6

Old and New Mezzanines Installed

Page 7: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Optical Tests at Rice, 2012-2013

7

n Three MPC boards with the new mezzanines

n SP10 prototype

n Test software is available, various PRBS and random

patterns

n Random patterns from MPC FIFO to SP10 FIFO under

slow VME control: 10K iterations (510 frames each);

no errors, all boards

n PRBS tests OK, BER<10-13

MPC SP10 CCB

Page 8: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Latency Measurements

8

■ Present MPC-to-SP system at CMS: 580 ns - TLK2501 Transmitter (1.6Gbps - 80MHz) ~23 ns - 100 m optical MMF fiber ~500 ns - TLK2501 Receiver (1.6Gbps - 80MHz) ~57 ns

■ New system (prototypes): 589 ns - Spartan-6 GTP Transmitter (3.2Gbps – 160MHz) ~20 ns (without Tx buffer, measured) - 100 m optical MMF fiber ~500 ns - Virtex-6 GTX receiver (3.2Gbps – 160MHz) ~69 ns (without Rx buffer, estimate)

Page 9: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Other Measurements

9

■ Power consumption: - Spartan-6 FPGA ~1A Vccint (1.2V) ~0.15A Vccaux+Vcco (3.3V) ~ 0.8A GTPs (1.2V) - 3 MIC69501 voltage regulators on a mezzanine board passed reactor irradiation test at TAMU in 2011 - MPC (main board + Spartan-6 mezzanine) <4A @ 3.3V

Page 10: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Optical Fibers for P.5

10

● Trunk cable with 4 connectorized cords (similar to one proposed for the DT upgrade). Each cord has 12 fibers. Need 36 cables for 60 peripheral crates, one spare cord per crate.

● Cable sample was successfully tested at UF in April 2013 ● Purchase order has been placed through CERN in April 2013

Page 11: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Irradiation Tests of the FPGA (1)

11

■ 66 MeV proton accelerator at Crocker Nuclear Laboratory, UC Davis ■ Wide range of beam fluxes typically from 104 to 109 p/cm2 /s

Page 12: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Irradiation Tests of the FPGA (2)

12

■ Irradiated with 1 kRad at a rate of ~1 Rad/sec (convenient to detect SEU) ● 75 Single Event Upsets (SEU): ● 5 to 15 seconds between SEU ● Average dose to get an error ~13 Rad. With the accumulated fluence of 3*1011 protons/cm2, the cross section of SEU is 75 / 3x1011 = 2.5x10-9 cm2 . ● Assuming 10-year fluence of ~1011 neutrons per cm2 [1] at full LHC design luminosity, the worst case SEU rate would be 2.5x10-9 cm2 x 1011 neutrons/cm2 / 5x107 sec = 5x10-6, or 1 SEU in ~ 55 hours per device [1] http://cmsdoc.cern.ch/~huu/tut1.pdf

■ Irradiated with 30 kRad at a rate 80 Rad/sec (10 years of LHC exposure in the ME1/1 area with a safety factor 3) ● Many upsets ● FPGA survived the test■ Irradiated with 100 kRad at a rate of 360 Rad/sec ● Many upsets ● FPGA survived the test■ Irradiated with ~300 Rad at a rate of ~1 Rad/sec again (repeat of first test) ● 50 SEU in 5 minutes ● Average dose to get an error ~6 Rad, ~2 times higher than in test 1 ● FPGA is fully functional

Page 13: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

Irradiation Tests of the EPROM

13

■ Irradiated with 1 MeV equivalent fluence at ~10.5*1012 n/cm2 at the TAMU cyclotron in April 2013 ■ Equivalent to ~30kRad, or 30 years of LHC exposure in ME1/1 area■ Device was read back; not a single bit change, as expected

XCF32P PROM

Page 14: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

14

What Needs to Be Done in 2013-14

■ Implement new data format MPC-to-SP - ready for MPC, but not tested with the uTCA SP

■ Need to set up a test stand at Rice: Track Finder VME crate (exists) - MPC (special slot) - SP05 (to be able to check three old optical links) - CCB - TTCvi/vx New uTCA crate (exists) - controller (need to be purchased) - AMC13 card (one, currently at UF) - SP12 (from UF) Software to run uTCA

■ Will need similar test stand at bld.904 at CERN by summer 2014

Page 15: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

15

PCB and Parts

■ Mezzanine board: 10-layer PCB Optical transmitter board: 4-layer PCB

■ Xilinx FPGA and EPROM are readily available from stock Optical transmitter: single source (Avago), several weeks delivery other parts not a concern

Page 16: CSC Endcap Muon Port Card and Muon Sorter Upgrade Status May 2013

16

Muon Sorter Upgrade

■ Upgraded mezzanine board provides direct optical link to the interim calorimeter trigger