PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 7/08Supersedes 5/08
Standard FeaturesEnvironmentally friendly R-410A refrigerantHigh-effi ciency scroll compressorCopper tube / aluminum fi n coilsContactor with lugsHigh-capacity, steel-cased fi lter dryerSingle-point entry24-volt terminal stripConvertibleEasy to serviceBuilt-in fi lter rack with standard 2” fi ltersBottom utility entryARI Certifi ed; ETL Listed
Cabinet FeaturesHeavy-guage, galvanized-steel cabinet with UV-resistant powder-paint fi nishFull Perimeter RailCurb Fit
ContentsNomenclature ................................................. 2Product Specifi cations ................................. 3Airfl ow Data .................................................... 5Heat Kit Electrical Data ............................... 7Cooling Data Summary .............................. 9Expanded Cooling Data ............................10Dimensions ....................................................14Wiring Diagrams .........................................18Accessories ....................................................20
••••••••••••
•
••
The new Goodman® CPC Commercial Packaged Air Conditioners feature the environmentally friendly refrigerant R-410A, which is chlorine-free to help prevent damage to the ozone layer. Other features include a high-effi ciency scroll compressor and easy access for servicing. These units are housed in a heavy-gauge, galvanized-steel cabinet with UV-resistant power-paint fi nish.
CPC COMMERCIAL
11.5 EER
THREE-PHASE
7½- TO 10-TON SELF-CONTAINED
PACKAGED AIR CONDITIONER
COOLING CAPACITY: 90,000 — 118,000 BTU/H
PRODUCT SPECIFICATIONS
2 www.goodmanmfg.com SS-CPC90-120
NOMENCLATURE
C P C 060 070 1 D X X X
1 2 3 4,5,6 7,8,9 10 11 12 13 14 Factory-Installed Options
(Coming Soon)Brand Special Features
C Commercial X No Features
Configuration Special Treatment
P Packaged Multi-Position X No Treatment/ StandardAluminized Heat Exchanger (AH)
Application
C Cooling Economizer Options (Factory Installed)
G Gas Heat X No EconomizerH Heat Pump
Supply Fan/Drive Type/Motor
Nominal Gross Cooling Capacity B Belt Drive036 3 Tons 120 10 Tons D Direct Drive048 4 Tons 150 12½ tons H High-Static Belt Drive060 5 Tons 180 15 Tons072 6 Tons 240 20 Tons Voltage
090 7½ Tons 300 25 Tons 1 208v 1 Phase 4 460v 3 Phase102 8½ Tons 2 220/240V 1 Phase 5 5 380/415v 3 Phase 50 Hz
3 208v 3 Phase 7 575v 3 PhaseHeating Capacity
CPG CPC/CPH
070 70,000 BTU/h XXX No Heat105 105,000 BTU/h 010 10 kW Electric Heater140 140,000 BTU/h 015 15 kW Electric Heater210 210,000 BTU/h 020 20 kW Electric Heater350 350,000 BTU/h 025 25 kW Electric Heater400 400,000 BTU/h
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 3
PRODUCT SPECIFICATIONS — 7½ TONS
CPC090***3B*** CPC090***4B*** CPC090***7B***Cooling CapacityTotal BTU/h 90,000 90,000 90,000Sensible BTU/h 65,700 65,700 65,700EER 11.50 11.50 11.50Decibels 82.0 82.0 82.0ARI Reference #s 3000986 3000986 3000986Evaporator Motor / CoilMotor Type Belt Drive Belt Drive Belt DriveIndoor Nominal CFM 3,000 3,000 3,000Motor Speed Tap (Cooling) -- -- --Indoor motor FLA (Cooling) 7.8 3.9 2.7Horsepower / RPM 2.0 / 1725 2.0 / 1725 2.0 / 1725Piston Size (Cooling) 0.076 0.076 0.076Filter Size 16” x 24” x 2” 16” x 24” x 2” 16” x 24” x 2”Drain Size (NPT) ¾” ¾” ¾”R-410A Refrigerant Charge Cir #1(oz.) 215 215 215R-410A Refrigerant Charge Cir #2(oz.) 215 215 215Evaporator Coil Face Area (ft²) 10.2 10.2 10.2Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16Condenser Fan / CoilQuantity of condenser Fan Motors 2 2 2Horsepower - RPM ¼ - 1090 ¼ - 890 ¼ - 1,075Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4Outdoor Nominal CFM 76,00 76,00 76,00Face Area (ft²) 32.4 32.4 32.4Rows Deep / Fins per Inch 2 / 20 2 / 20 2 / 20Belt Drive Evap Fan Data# of Wheels (D x W) 1 (15” x 12”) 1 (15” x 12”) 1 (15” x 12”)Motor Sheave VL40 VL40 VL40Blower Sheave AK74 AK74 AK74Belt AX51 AX51 AX51Rows Deep / Fins per Inch 2 / 20 2 / 20 2 / 20Electrical DataVoltage / Phase / Frequency 208-230 / 3 / 60 460 / 3 / 60 575 / 3 / 60Quantity of Compressors 2 2 2Compressor RLA / LRA 13.1 / 83.1 6.1 / 41.0 4.4 / 33.0Max External Static 1.5” 1.5” 1.5”Outdoor Fan HP / RLA (2) ¼ / 1.4 (2) ¼ / 0.8 (2) ¼ / 0.6Total Unit Amps 36.9 17.7 12.6Min. Circuit Ampacity¹ 40 19 14Max. Overcurrent Protection (amps)² 50 25 15Entrance Power Supply Locating Dimple Locating Dimple Locating DimpleEntrance Control Voltage Locating Dimple Locating Dimple Locating DimpleOperating Weight (lbs) 1110 1110 1110Ship Weight (lbs) 1150 1150 1150
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
PRODUCT SPECIFICATIONS
4 www.goodmanmfg.com SS-CPC90-120
PRODUCT SPECIFICATIONS — 10 TONS
CPC120***3B*** CPC120***4B*** CPC120***7B***Cooling CapacityTotal BTU/h 118,000 118,000 118,000Sensible BTU/h 87,300 87,300 87,300EER / IPLV 11.50 / 12.00 11.50 / 12.00 11.50 / 12.00Decibels 83.0 83.0 83.0ARI Reference #s 3023833 3023833 3023833Evaporator Motor / CoilMotor Type Belt Drive Belt Drive Belt DriveIndoor Nominal CFM 4,000 4,000 4,000Motor Speed Tap (Cooling) -- -- --Indoor motor FLA (Cooling) 7.8 3.9 2.7Horsepower - RPM 2.0/1725 2.0/1725 2.0/1725Piston Size (Cooling) 0.086 0.086 0.086Filter Size ( 4) 16” x 24” x 2” ( 4) 16” x 24” x 2” ( 4) 16” x 24” x 2”Drain Size (NPT) ¾” ¾” ¾”R-410A Refrigerant Charge Cir #1(oz.) 220 220 220R-410A Refrigerant Charge Cir #2(oz.) 220 220 220Evaporator Coil Face Area (ft²) 10.2 10.2 10.2Rows Deep / Fins per Inch 4 / 14 4 / 14 4 / 14Condenser Fan / CoilQuantity of condenser Fan Motors 2 2 2Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3Outdoor Nominal CFM 7,200 7,200 7,200Face Area (ft²) 32.4 32.4 32.4Rows Deep - Fins per Inch 2/2 rows - 22 fpi 2/2 rows - 22 fpi 2/2 rows - 22 fpiBelt Drive Evap Fan Data# of Wheels (D x W) (1) 15” x 15” (1) 15” x 15” (1) 15” x 15”Motor Sheave VL40 VL40 VL40Blower Sheave AK74 AK74 AK74Belt AX51 AX51 AX51Electrical DataVoltage/Phase/ Frequency 208-230/3/60 460/3/60 575/3/60Quantity of Compressors 2 2 2Compressor RLA / LRA ea. 16/110.0 7.8/52.0 5.7/38.9Standard Max Static 2.0” 2.0” 2.0”Outdoor Fan RLA ea. 2.40 1.20 0.89Total Unit Amps 45 22 16Min. Circuit Ampacity¹ 49 24 17Max. Overcurrent Protection (amps)² 60.0 30 20Entrance Power Supply Locating Dimple Locating Dimple Locating DimpleEntrance Control Voltage Locating Dimple Locating Dimple Locating DimpleOperating Weight (lbs) 1135 1135 1135Ship Weight (lbs) 1175 1175 1175
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 5
AIRFLOW DATA — 7½ TONS
Standard Belt Drive — Down Shot
ESP, In H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.1 3617 704 1.07 3293 653 0.840.3 3541 749 1.15 3179 704 0.88 2757 656 0.660.5 3447 798 1.23 3049 754 0.94 2606 710 0.710.7 3400 848 1.33 2950 798 1.01 2474 754 0.750.9 3303 890 1.41 2871 848 1.11 2408 804 0.821.1 2838 897 1.23
High-Static Belt Drive — Down Shot
ESP, In H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.9
DO NOTOPERATE
3401 909 1.511.1 3428 965 1.71 2943 915 1.31.3 3471 1015 1.9 3012 971 1.5 2423 920 1.121.5 3722 1063 2.25 3041 1023 1.67 2503 976 1.311.7 3359 1075 2.04 2540 1031 1.51.9 3381 1119 2.22 2890 1080 1.782.1 3089 1129 2.04
Standard Belt Drive — Horizontal
ESP, In H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.1 3625 701 1.08 3309 660 0.860.3 3815 797 1.44 3468 747 1.11 3177 703 0.88 2796 663 0.680.5 3780 841 1.52 3405 803 1.23 3053 753 0.94 2608 709 0.68 2225 665 0.530.7 3687 885 1.6 3327 847 1.29 2968 805 1.02 2423 758 0.730.9 3236 891 1.39 2850 852 1.1 2352 807 0.81.1 2713 896 1.17
High-Static Belt Drive — Horizontal
ESP, In H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.9
DO NOTOPERATE
3447 902 1.541.1 3398 956 1.65 3006 908 1.311.3 3486 1008 1.87 2960 962 1.441.5 3514 1057 2.07 2949 1019 1.621.7 3388 1103 2.18 3036 1069 1.841.9 2959 1114 2.02.1 2527 1124 1.86
Notes :Assume dry coil with fi lter in place; CFM correction for wet coil = 3%Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could require a larger motor. Minimum rated SCFM is 350 per ton.
PRODUCT SPECIFICATIONS
6 www.goodmanmfg.com SS-CPC90-120
AIRFLOW DATA — 10 TONS
Standard Belt-Drive — Down Shot
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.2 4632 781 1.76 4203 742 1.41 3927 691 1.17 3510 658 0.90.4 4488 825 1.85 4183 783 1.54 3733 748 1.23 3512 693 10.6 4442 880 2.02 4066 830 1.63 3717 786 1.310.8 4001 885 1.77 3622 835 1.411 3603 890 1.55
1.2
High-Static Belt-Drive — Down Shot
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.8 4435 940 2.22 4078 886 1.821 4462 997 2.47 4103 945 2.05 3539 892 1.52
1.2 4513 1054 2.75 4127 1003 2.26 3568 950 1.711.4 4126 1064 2.52 3597 1008 1.921.6 4438 1116 2.97 3759 1069 2.251.8 3956 1124 2.552 4050 1179 3.05 3473 1132 2.32
Standard Belt-Drive — Horizontal
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.2 4562 736 1.58 4253 691 1.29 3893 642 10.4 4497 780 1.7 4200 736 1.41 3735 691 1.06 3322 648 0.830.6 4467 824 1.81 4221 784 1.55 3689 741 1.180.8 4564 873 2.06 4170 830 1.68 3677 785 1.291 4129 875 1.81 3498 835 1.34
1.2 3558 879 1.49
High-Static Belt-Drive — Horizontal
ESP, In
H2O
Turns Open0 1 2 3 4 5
CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.8
DO NOT OPERATE
4602 884 2.131 4749 940 2.44 4180 885 1.89
1.2 4251 945 2.12 3642 896 1.581.4 4443 1001 2.5 3744 951 1.81.6 4587 1056 2.82 3971 1006 2.171.8 4760 1105 3.23 4071 1061 2.43 3342 1012 1.862 4364 1114 2.91 3579 1067 2.05
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 7
HEAT KIT ELECTRICAL DATA (BLOWER ONLY, HEAT MODE) — 7½ TONS
MINIMUM AIRFLOW FOR ELECTRIC HEAT
Heater Size (kW) Minimum CFM15 3,00030 3,00043 3,000
KW CORRECTION FACTORS
kW Correction Factor (for 1- & 3-Phase Units)Supply Voltage 240 230 220 210 208Correction Factor 1 0.93 0.82 0.78 0.76
kW Correction Factor (for 480V Units)Supply Voltage 460 440 430Correction Factor 0.92 0.84 0.8
For other voltage, use voltage² / 480²
kW Correction Factor (for 575V Units)Supply Voltage 560 550 540Correction Factor 0.95 0.91 0.88
Multiply rated kW by correction factor to get actual kW.
Model and Heat Kit Usage
MCA¹ @ 208 / 240V
MOP² (amps) @ 208 / 240V
Actual kW & BTU @ 240V
RecommendedAirfl ow Range
CPC090***3B*** 40 50EHK3-16 48 / 55 50 / 60 15 3000 - 3375 CFMEHK3-30 87 / 100 90 / 100 30 3000 - 3375 CFMEHK3-45 121 / 139 125 / 150 43 3000 - 3375 CFM
Model and Heat Kit Usage
MCA¹ @ 480V
MOP² (amps) @ 480V
Actual kW & BTU @ 480V
RecommendedAirfl ow Range
CPC090***4B*** 19 25EHK4-16 27 30 15 3000 - 3375 CFMEHK4-30 50 50 30 3000 - 3375 CFMEHK4-45 70 70 43 3000 - 3375 CFM
Model and Heat Kit Usage
MCA¹@ 575V
MOP² (amps) @ 575V
Actual kW & BTU @ 575V
RecommendedAirfl ow Range
CPC090***7B*** 14 15EHK7-16 22 25 15 ---EHK7-30 41 45 30 ---EHK7-45 57 60 43 ---
¹ Minimum Circuit Ampacity² Maximum Overcurrent Protection device
PRODUCT SPECIFICATIONS
8 www.goodmanmfg.com SS-CPC90-120
HEAT KIT ELECTRICAL DATA (BLOWER ONLY, HEAT MODE) — 10 TONS
KW CORRECTION FACTOR
kW Correction Factor (for 1- & 3-Phase Units)Supply Voltage 240 230 220 210 208Correction Factor 1 0.93 0.82 0.78 0.76
kW Correction Factor for 480V UnitsActual Voltage 460 440 430Correction Factor 0.92 0.84 0.8
For other voltage use voltage² / 480²
kW Correction Factor for 575V UnitsSupply Voltage 560 550 540Correction Factor 0.95 0.91 0.88
Multiply rated kW by correction factor to get actual kW
MINIMUM AIRFLOW FOR ELECTRIC HEAT
Heater Size (kW) Min. CFM Down-shot
Min. CFM Horizontal
15 4,000 4,000
30 4,000 4,000
43 4,000 4,000
Model and Heat Kit Usage
MCA¹ @ 208 / 240V
MOP² (amps) @ 208 / 240V
Actual kW & BTU @ 240V
RecommendedAirfl ow Range
CPC120***3B*** 49 60EHK3-16 48 / 55 50 / 60 15 3500 - 4500 CFMEHK3-30 87 / 100 90 / 100 30 3500 - 4500 CFMEHK3-45 121 / 139 125 / 150 43 4000 - 4500 CFM
Model and Heat Kit Usage
MCA¹ @ 208 / 240V
MOP² (amps) @ 208 / 240V
Actual kW & BTU @ 240V
RecommendedAirfl ow Range
CPC120***3H*** 50 60EHK3-16 49 / 57 50 / 60 15EHK3-30 88 / 102 90 / 110 30EHK3-45 122 / 141 125 / 150 43
Model and Heat Kit Usage
MCA¹@ 480V
MOP² (amps) @ 480V
Actual kW & BTU @ 480V
RecommendedAirfl ow Range
CPC120***4B*** 24 30EHK4-16 27 30 15 3500 - 4500 CFMEHK4-30 50 50 30 3500 - 4500 CFMEHK4-45 70 70 43 4000 - 4500 CFM
Model and Heat Kit Usage
MCA¹@ 575V
MOP² (amps) @ 575V
Actual kW & BTU @ 575V
RecommendedAirfl ow Range
CPC0120***7B*** 17 20EHK7-16 22 25 15 3500 - 4500 CFMEHK7-30 41 45 30 3500 - 4500 CFMEHK7-45 57 60 43 4000 - 4500 CFM
¹ Minimum Circuit Ampacity² Maximum Overcurrent Protection device
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 9
COOLING DATA SUMMARY — 7½ TONS
Indoor AirCondenser Air Temperature
75 85 95 105 115SCFM WB Total Sens Watts Total Sens Watts Total Sens Watts Total Sens Watts Total Sens Watts
2400
71 93.2 46.3 7.08 91.0 46.4 7.50 88.8 46.7 7.88 84.4 46.1 8.20 78.1 43.0 8.48
67 87.2 58.0 6.87 85.1 58.1 7.28 83.1 58.5 7.64 78.9 57.7 7.95 73.1 53.9 8.21
63 81.6 66.7 6.67 79.7 66.8 7.06 77.8 67.2 7.41 73.9 66.3 7.71 68.4 61.9 7.96
59 79.9 69.6 6.54 78.0 69.7 6.92 76.1 70.2 7.26 72.3 69.2 7.55 67.0 64.6 7.80
3000
71 101.0 52.1 7.25 98.6 52.1 7.69 96.2 52.5 8.07 91.4 51.8 8.40 84.7 48.3 8.69
67 94.5 65.2 7.03 92.3 65.2 7.45 90.0 65.7 7.83 85.5 64.8 8.14 79.2 60.5 8.42
63 88.5 75.0 6.82 86.3 75.0 7.23 84.2 75.6 7.59 80.0 74.5 7.89 74.1 69.6 8.16
59 86.6 78.2 6.69 84.5 78.3 7.08 82.4 78.8 7.43 78.3 77.7 7.73 72.5 72.5 7.99
3375
71 104.1 56.2 7.30 101.6 56.3 7.75 99.1 56.7 8.14 94.1 55.9 8.47 87.2 52.2 8.76
67 97.3 70.4 7.08 95.0 70.5 7.51 92.7 71.0 7.89 88.1 70.0 8.21 81.6 65.4 8.48
63 91.1 80.9 6.88 88.9 81.0 7.29 86.8 81.6 7.65 82.4 82.4 7.96 76.4 76.4 8.22
59 89.2 84.5 6.74 87.0 87.0 7.14 84.9 84.9 7.49 80.7 80.7 7.79 74.7 74.7 8.05
Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil.For sensible heat capacities at other than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of evaporator coil air per degree above 80°F.Capacities at 95°F Outdoor, 75°F DB and 63°F WB IndoorTotal MBTU/h 84.8 Sensible MBTU/h 66.1 Latent MBTU/h 18.7
PRODUCT SPECIFICATIONS
10 www.goodmanmfg.com SS-CPC90-120
EXPANDED COOLING DATA — 7½ TONS
Out
door
Am
bien
t Tem
pera
ture
6575
8595
105
115
Ente
ring
Indo
or W
et B
ulb
Tem
pera
ture
IDB
*A
irfl o
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
3375
MB
h88
.291
.410
0.2
-86
.189
.397
.8-
84.1
87.2
95.5
-82
.085
.093
.2-
77.9
80.8
88.5
-72
.274
.882
.0-
S/T
0.73
0.61
0.42
-0.
760.
630.
44-
0.78
0.65
0.45
-0.
800.
670.
47-
0.83
0.70
0.48
-0.
840.
700.
49-
∆T18
1512
-18
1512
-18
1512
-18
1612
-18
1512
-17
1411
-kW
6.19
6.32
6.50
-6.
646.
776.
98-
7.03
7.17
7.39
-7.
377.
537.
76-
7.67
7.83
8.08
-7.
928.
098.
35-
Am
ps20
.420
.821
.2-
21.6
22.0
22.5
-23
.023
.424
.0-
24.1
24.6
25.2
-25
.325
.826
.5-
26.5
27.0
27.7
-H
i PR
234
252
266
-26
228
229
8-
298
321
339
-34
036
638
6-
382
411
434
-42
245
448
0-
Lo P
R10
811
512
6-
114
122
133
-11
912
613
8-
125
133
145
-13
113
915
2-
135
144
157
-
3000
MB
h85
.688
.797
.2-
83.6
86.7
95.0
-81
.684
.692
.7-
79.7
82.6
90.5
-75
.778
.485
.9-
70.1
72.6
79.6
-S
/T0.
700.
580.
40-
0.72
0.61
0.42
-0.
740.
620.
43-
0.77
0.64
0.44
-0.
800.
660.
46-
0.80
0.67
0.46
-∆T
1816
12-
1916
12-
1916
12-
1916
12-
1816
12-
1715
11-
kW6.
156.
276.
45-
6.59
6.72
6.92
-6.
987.
127.
34-
7.32
7.47
7.70
-7.
617.
778.
01-
7.86
8.03
8.28
-A
mps
20.3
20.6
21.1
-21
.421
.822
.4-
22.8
23.2
23.8
-24
.024
.425
.0-
25.1
25.6
26.3
-26
.326
.827
.5-
Hi P
R23
124
926
3-
260
279
295
-29
531
833
6-
336
362
382
-37
840
743
0-
418
450
475
-Lo
PR
107
114
124
-11
312
013
2-
118
125
137
-12
413
214
4-
130
138
150
-13
414
315
6-
2400
MB
h79
.081
.989
.7-
77.2
80.0
87.7
-75
.478
.185
.6-
73.5
76.2
83.5
-69
.872
.479
.3-
64.7
67.1
73.5
-S
/T0.
670.
560.
39-
0.70
0.58
0.40
-0.
720.
600.
41-
0.74
0.62
0.43
-0.
770.
640.
44-
0.77
0.65
0.45
-∆T
2018
13-
2118
14-
2118
14-
2118
14-
2118
13-
1917
13-
kW6.
016.
136.
31-
6.44
6.57
6.76
-6.
816.
957.
16-
7.15
7.29
7.52
-7.
437.
587.
82-
7.67
7.83
8.08
-A
mps
19.9
20.2
20.7
-21
.021
.421
.9-
22.3
22.7
23.3
-23
.523
.924
.5-
24.6
25.1
25.7
-25
.726
.226
.9-
Hi P
R22
424
225
5-
252
271
286
-28
630
832
6-
326
351
371
-36
739
541
7-
406
436
461
-Lo
PR
104
111
121
-11
011
712
8-
114
121
133
-12
012
813
9-
126
134
146
-13
013
815
1-
75
3375
MB
h89
.792
.310
0.0
107.
387
.690
.297
.610
4.8
85.5
88.0
95.3
102.
383
.485
.993
.099
.879
.381
.688
.394
.873
.475
.681
.887
.8S
/T0.
830.
750.
560.
360.
860.
770.
580.
380.
890.
790.
600.
390.
910.
820.
620.
400.
950.
850.
640.
410.
960.
860.
650.
42∆T
2019
1511
2119
1611
2119
1611
2119
1611
2019
1511
1918
1410
kW6.
246.
366.
556.
756.
696.
827.
037.
257.
087.
237.
457.
697.
437.
597.
838.
077.
737.
898.
148.
407.
998.
168.
428.
69A
mps
20.5
20.9
21.4
22.0
21.7
22.1
22.7
23.3
23.1
23.5
24.1
24.8
24.3
24.8
25.4
26.2
25.5
26.0
26.7
27.5
26.7
27.2
27.9
28.8
Hi P
R23
625
426
828
026
528
530
131
430
132
434
235
734
336
939
040
738
641
543
945
842
745
948
550
6Lo
PR
109
116
127
135
116
123
134
143
120
128
139
149
126
134
146
156
132
141
154
163
137
145
159
169
3000
MB
h87
.189
.797
.010
4.1
85.1
87.6
94.8
101.
783
.085
.592
.599
.381
.083
.490
.396
.977
.079
.285
.892
.071
.373
.479
.485
.3S
/T0.
790.
710.
540.
350.
820.
740.
560.
360.
840.
760.
570.
370.
870.
780.
590.
380.
900.
810.
610.
390.
910.
820.
620.
40∆T
2120
1611
2120
1611
2120
1611
2220
.016
1121
2016
1120
1815
10kW
6.19
6.32
6.50
6.70
6.64
6.77
6.98
7.19
7.03
7.17
7.39
7.63
7.38
7.53
7.76
8.01
7.67
7.83
8.08
8.34
7.92
8.09
8.35
8.62
Am
ps20
.420
.821
.221
.821
.622
.022
.523
.123
.023
.424
.024
.724
.124
.625
.226
.025
.325
.826
.527
.326
.527
.027
.728
.6H
i PR
234
252
266
277
262
282
298
311
298
321
339
354
340
366
386
403
382
411
434
453
422
454
480
501
Lo P
R10
811
512
613
411
412
213
314
111
912
613
814
712
513
314
515
413
113
915
216
213
514
415
716
7
2400
MB
h80
.482
.789
.696
.178
.580
.887
.593
.976
.678
.985
.491
.774
.877
.083
.389
.471
.073
.179
.285
.065
.867
.773
.378
.7S
/T0.
770.
690.
520.
330.
790.
710.
540.
350.
810.
730.
550.
350.
840.
750.
570.
370.
870.
780.
590.
380.
880.
790.
600.
38∆T
2422
1812
2422
1812
2422
1812
2422
1813
2422
1812
2220
1712
kW6.
066.
186.
366.
556.
496.
626.
827.
026.
877.
017.
227.
457.
207.
357.
587.
827.
497.
657.
888.
137.
737.
908.
158.
41A
mps
20.0
20.3
20.8
21.4
21.2
21.5
22.0
22.7
22.5
22.9
23.5
24.1
23.6
24.1
24.7
25.4
24.8
25.3
25.9
26.7
25.9
26.4
27.1
27.9
Hi P
R22
724
425
826
925
427
428
930
228
931
132
934
333
035
537
539
137
139
942
143
941
044
146
648
6Lo
PR
105
112
122
130
111
118
129
137
115
123
134
143
121
129
141
150
127
135
147
157
131
140
153
162
* E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Sha
ded
area
refl e
cts
AC
CA
(TVA
) con
ditio
nsH
igh
pres
sure
is m
easu
red
at th
e liq
uid
line
gaug
e po
rt co
nnec
tion
Low
pre
ssur
e is
mea
sure
d at
the
com
pres
sor s
uctio
n ga
uge
port
conn
ectio
n.
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 11
EXPANDED COOLING DATA — 7½ TONS (CONT.)O
utdo
or A
mbi
ent T
empe
ratu
re65
7585
9510
511
5En
terin
g In
door
Wet
Bul
b Te
mpe
ratu
reID
B*
Airfl
ow
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
80
3375
MB
h91
.393
.399
.710
6.5
89.2
91.1
97.3
104.
187
.088
.995
.010
1.6
84.9
86.8
92.7
99.1
80.7
82.4
88.1
94.1
74.7
76.4
81.6
87.2
S/T
0.91
0.86
0.70
0.52
0.95
0.89
0.72
0.54
1.00
0.91
0.74
0.55
1.00
0.94
0.77
0.57
1.00
1.00
0.79
0.59
1.00
1.00
0.80
0.60
∆T23
2219
1523
2219
1524
2219
1523
2219
1522
2219
1520
2118
14kW
6.29
6.41
6.60
6.80
6.74
6.88
7.08
7.30
7.14
7.29
7.51
7.75
7.49
7.65
7.89
8.14
7.79
7.96
8.21
8.47
8.05
8.22
8.48
8.76
Am
ps20
.721
.021
.522
.121
.922
.322
.823
.523
.323
.724
.325
.024
.524
.925
.626
.325
.726
.226
.927
.726
.927
.428
.129
.0H
i PR
238
257
271
283
268
288
304
317
304
328
346
361
347
373
394
411
390
420
443
462
431
464
490
511
Lo P
R11
011
812
813
711
712
413
614
412
112
914
115
012
713
614
815
813
414
215
516
513
814
716
017
1
3000
MB
h88
.690
.696
.810
3.4
86.6
88.5
94.5
101.
084
.586
.392
.398
.682
.484
.290
.096
.278
.380
.085
.591
.472
.574
.179
.284
.7S
/T0.
870.
820.
670.
500.
900.
850.
690.
520.
930.
870.
710.
530.
960.
900.
730.
550.
990.
930.
760.
571.
000.
940.
760.
57∆T
2423
2016
2423
2016
2423
2016
2423
20.0
1624
2320
1622
2119
15kW
6.24
6.36
6.55
6.75
6.69
6.82
7.03
7.25
7.08
7.23
7.45
7.69
7.43
7.59
7.83
8.07
7.73
7.89
8.14
8.40
7.99
8.16
8.42
8.69
Am
ps20
.520
.921
.422
.021
.722
.122
.723
.323
.123
.524
.124
.824
.324
.825
.426
.225
.526
.026
.727
.526
.727
.227
.928
.8H
i PR
236
254
268
280
265
285
301
314
301
324
342
357
343
369
390
407
386
415
439
458
427
459
485
506
Lo P
R10
911
612
713
511
612
313
414
312
012
813
914
912
613
414
715
613
214
115
416
413
714
515
916
9
2400
MB
h81
.883
.689
.395
.579
.981
.687
.293
.278
.079
.785
.191
.076
.177
.883
.188
.872
.373
.978
.984
.467
.068
.473
.178
.1S
/T0.
840.
790.
640.
480.
870.
820.
670.
500.
890.
840.
680.
510.
920.
860.
700.
530.
960.
900.
730.
550.
970.
910.
740.
55∆T
2625
2218
2726
2218
2726
2218
2726
2218
2725
2218
2524
2116
kW6.
106.
226.
406.
606.
546.
676.
877.
086.
927.
067.
287.
507.
267.
417.
647.
887.
557.
717.
958.
207.
807.
968.
218.
48A
mps
20.1
20.5
21.0
21.5
21.3
21.7
22.2
22.8
22.6
23.1
23.6
24.3
23.8
24.2
24.9
25.6
25.0
25.4
26.1
26.9
26.1
26.6
27.3
28.1
Hi P
R22
924
626
027
125
727
729
230
529
231
533
234
633
335
837
839
537
540
342
644
441
444
547
049
0Lo
PR
106
113
123
131
112
119
130
139
116
124
135
144
122
130
142
151
128
136
149
159
133
141
154
164
85
3375
MB
h92
.994
.799
.210
5.8
90.7
92.5
96.8
103.
388
.690
.394
.510
0.9
86.4
88.1
92.2
98.4
82.1
83.7
87.6
93.5
76.0
77.5
81.2
86.6
S/T
0.96
0.92
0.83
0.68
0.99
0.96
0.86
0.70
1.00
0.98
0.89
0.72
1.00
1.00
0.92
0.74
1.00
1.00
0.95
0.77
1.00
1.00
0.96
0.78
∆T24
2423
2025
2423
2024
2423
2024
2423
2022
2323
2021
2121
18kW
6.33
6.46
6.65
6.85
6.79
6.93
7.14
7.36
7.19
7.34
7.57
7.81
7.55
7.71
7.95
8.20
7.85
8.02
8.27
8.54
8.12
8.29
8.55
8.83
Am
ps20
.821
.221
.722
.322
.022
.423
.023
.623
.423
.924
.525
.224
.725
.125
.826
.525
.926
.427
.127
.927
.127
.628
.429
.2H
i PR
241
259
274
285
270
291
307
320
307
331
349
364
350
377
398
415
394
424
448
467
435
468
495
516
Lo P
R11
211
913
013
811
812
513
714
612
213
014
215
212
913
714
915
913
514
315
716
713
914
816
217
3
3000
MB
h90
.291
.996
.310
2.7
88.1
89.8
94.0
100.
386
.087
.691
.897
.983
.985
.589
.695
.579
.781
.285
.190
.873
.875
.278
.884
.1S
/T0.
910.
880.
800.
650.
950.
910.
820.
670.
970.
940.
850.
691.
000.
970.
870.
711.
001.
000.
910.
741.
001.
000.
910.
74∆T
2525
2320
2625
2421
2625
2421
2625
2421
2425
2420
2323
2219
kW6.
296.
416.
606.
806.
746.
887.
087.
307.
147.
297.
517.
757.
497.
657.
898.
147.
797.
968.
218.
478.
058.
228.
488.
76A
mps
20.7
21.0
21.5
22.1
21.9
22.3
22.8
23.5
23.3
23.7
24.3
25.0
24.5
24.9
25.6
26.3
25.7
26.2
26.9
27.7
26.9
27.4
28.1
29.0
Hi P
R23
825
727
128
326
828
830
431
730
432
834
636
134
737
339
441
139
042
044
346
243
146
449
051
1Lo
PR
110
118
128
137
117
124
136
144
121
129
141
150
127
136
148
158
134
142
155
165
138
147
160
171
2400
MB
h83
.284
.888
.994
.881
.382
.986
.892
.679
.480
.984
.790
.477
.478
.982
.788
.273
.675
.078
.583
.868
.169
.472
.777
.6S
/T0.
880.
850.
770.
620.
910.
880.
800.
650.
940.
900.
820.
660.
970.
930.
840.
681.
000.
970.
870.
711.
000.
980.
880.
71∆T
2828
2623
2828
2623
2828
2623
2928
2723
2828
2623
2626
2521
kW6.
156.
276.
456.
656.
596.
726.
927.
136.
977.
127.
337.
567.
327.
477.
707.
947.
617.
778.
018.
277.
868.
028.
288.
55A
mps
20.3
20.6
21.1
21.7
21.4
21.8
22.3
23.0
22.8
23.2
23.8
24.5
24.0
24.4
25.0
25.8
25.1
25.6
26.3
27.1
26.3
26.8
27.5
28.4
Hi P
R23
124
926
327
426
027
929
530
829
531
833
535
033
636
238
239
937
840
743
044
841
845
047
549
5Lo
PR
107
114
124
133
113
120
131
140
118
125
137
146
124
131
144
153
130
138
150
160
134
143
156
166
* E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Sha
ded
area
refl e
cts
AR
I Rat
ing
Con
ditio
nsH
igh
pres
sure
is m
easu
red
at th
e liq
uid
line
gaug
e po
rt co
nnec
tion
Low
pre
ssur
e is
mea
sure
d at
the
com
pres
sor s
uctio
n ga
uge
port
conn
ectio
n.
PRODUCT SPECIFICATIONS
12 www.goodmanmfg.com SS-CPC90-120
EXPANDED COOLING DATA — 10 TONS
Out
door
Am
bien
t Tem
pera
ture
6575
8595
105
115
Ente
ring
Indo
or W
et B
ulb
Tem
pera
ture
IDB
Airfl
ow
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
5963
6771
70
4500
MB
h11
5.6
119.
813
1.3
-11
2.9
117.
112
8.3
-11
0.3
114.
312
5.2
-10
7.6
111.
512
2.1
-10
2.2
105.
911
6.0
-94
.798
.110
7.5
-
S/T
0.74
0.62
0.43
-0.
770.
640.
45-
0.79
0.66
0.46
-0.
820.
680.
47-
0.85
0.71
0.49
-0.
850.
710.
49-
∆T18
1512
-18
1512
-18
1512
-18
1612
-18
1512
-17
1411
-
Hi P
r24
726
528
0-
277
298
314
-31
533
935
8-
358
386
407
-40
343
445
8-
446
479
506
-
Lo P
r10
611
312
4-
112
120
131
-11
712
413
6-
123
131
143
-12
913
714
9-
133
142
155
-
4000
MB
h11
2.3
116.
412
7.5
-10
9.7
113.
712
4.5
-10
7.0
110.
912
1.6
-10
4.4
108.
211
8.6
-99
.210
2.8
112.
7-
91.9
95.3
104.
4-
S/T
0.71
0.59
0.41
-0.
730.
610.
43-
0.75
0.63
0.44
-0.
780.
650.
45-
0.81
0.67
0.47
-0.
810.
680.
47-
∆T18
1612
-19
1612
-19
1612
-19
1612
-18
1612
-17
1511
-
Hi P
r24
426
327
7-
274
295
311
-31
233
535
4-
355
382
403
-39
943
045
4-
441
475
501
-
Lo P
r10
511
212
2-
111
118
129
-11
612
313
4-
122
129
141
-12
713
514
8-
132
140
153
-
3200
MB
h10
3.6
107.
411
7.7
-10
1.2
104.
911
4.9
-98
.810
2.4
112.
2-
96.4
99.9
109.
5-
91.6
94.9
104.
0-
84.8
87.9
96.3
-
S/T
0.68
0.57
0.40
-0.
710.
590.
41-
0.73
0.61
0.42
-0.
750.
630.
43-
0.78
0.65
0.45
-0.
780.
660.
45-
∆T20
1813
-21
1814
-21
1814
-21
1814
-20
1813
-19
1713
-
Hi P
r23
725
526
9-
266
286
302
-30
232
534
3-
344
370
391
-38
741
744
0-
428
460
486
-
Lo P
r10
210
911
9-
108
115
125
-11
211
913
0-
118
125
137
-12
413
114
3-
128
136
148
-
75
4500
MB
h11
7.6
121.
113
1.0
140.
611
4.9
118.
312
8.0
137.
411
2.1
115.
412
5.0
134.
110
9.4
112.
612
1.9
130.
810
3.9
107.
011
5.8
124.
396
.399
.110
7.3
115.
1
S/T
0.84
0.76
0.57
0.37
0.88
0.78
0.59
0.38
0.90
0.80
0.61
0.39
0.93
0.83
0.63
0.40
0.96
0.86
0.65
0.42
0.97
0.87
0.66
0.42
∆T20
1915
1121
1916
1121
1916
1121
1916
1120
1915
1119
1814
10
Hi P
r24
926
828
329
528
030
131
833
131
834
236
137
736
239
041
142
940
743
846
348
345
048
451
153
3
Lo P
r10
711
412
513
311
412
113
214
011
812
613
714
612
413
214
415
313
013
815
116
113
414
315
616
6
4000
MB
h11
4.2
117.
512
7.2
136.
611
1.5
114.
812
4.3
133.
410
8.9
112.
112
1.3
130.
210
6.2
109.
311
8.4
127.
010
0.9
103.
911
2.4
120.
793
.596
.210
4.2
111.
8
S/T
0.81
0.72
0.55
0.35
0.84
0.75
0.57
0.36
0.86
0.77
0.58
0.37
0.88
0.79
0.60
0.38
0.92
0.82
0.62
0.40
0.93
0.83
0.63
0.40
∆T21
1916
1121
2016
1121
2016
1122
2016
1121
2016
1120
1815
10
Hi P
r24
726
528
029
227
729
831
532
831
533
935
837
335
838
640
742
540
343
445
847
844
648
050
652
8
Lo P
r10
611
312
413
211
212
013
113
911
712
413
614
512
313
114
315
212
913
714
915
913
314
215
516
5
3200
MB
h10
5.4
108.
511
7.4
126.
010
2.9
106.
011
4.7
123.
110
0.5
103.
411
2.0
120.
298
.010
0.9
109.
211
7.2
93.1
95.9
103.
811
1.4
86.3
88.8
96.1
103.
2
S/T
0.78
0.69
0.53
0.34
0.81
0.72
0.55
0.35
0.83
0.74
0.56
0.36
0.85
0.76
0.58
0.37
0.88
0.79
0.60
0.39
0.89
0.80
0.60
0.39
∆T24
2218
1224
2218
1224
2218
1224
2218
1324
2218
1222
2017
12
Hi P
r23
925
727
228
426
828
930
531
830
532
934
736
234
837
439
541
239
142
144
546
443
246
549
151
2
Lo P
r10
311
012
012
810
911
612
713
511
312
113
214
011
912
713
814
712
513
314
515
412
913
715
016
0
IDB
= E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Des
ign
Sup
erhe
at 7
±2 °
F, D
esig
n S
ubco
olin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
suct
ion
and
liqui
d ac
cess
fi tti
ngs;
AR
I 95°
test
con
ditio
nsH
igh
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
suct
ion
serv
ice
acce
ss fi
tting
s.S
hade
d ar
ea re
fl ect
s A
CC
A (T
VA) c
ondi
tions
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 13
EXPANDED COOLING DATA — 10 TONS (CONT.)O
utdo
or A
mbi
ent T
empe
ratu
re65
7585
9510
511
5En
terin
g In
door
Wet
Bul
b Te
mpe
ratu
reID
BA
irfl o
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
4500
MB
h11
9.7
122.
313
0.7
139.
711
6.9
119.
412
7.6
136.
411
4.1
116.
612
4.6
133.
211
1.3
113.
812
1.5
129.
910
5.8
108.
111
5.5
123.
498
.010
0.1
107.
011
4.3
S/T
0.93
0.87
0.71
0.53
0.96
0.90
0.73
0.55
1.00
0.92
0.75
0.56
1.00
0.95
0.78
0.58
1.00
1.00
0.81
0.60
1.00
1.00
0.81
0.61
∆T23
2219
1523
2219
1523
2219
1523
2219
1522
2219
1520
2018
14
Hi P
r25
227
128
629
828
230
432
133
532
134
636
538
136
639
441
643
341
144
346
848
845
548
951
753
9
Lo P
r10
911
612
613
411
512
213
314
211
912
713
814
712
513
314
515
513
114
015
216
213
614
415
816
8
4000
MB
h11
6.2
118.
712
6.9
135.
611
3.5
116.
012
3.9
132.
411
0.8
113.
212
1.0
129.
310
8.1
110.
411
8.0
126.
110
2.7
104.
911
2.1
119.
895
.197
.210
3.8
111.
0
S/T
0.88
0.83
0.67
0.50
0.92
0.86
0.70
0.52
0.94
0.88
0.72
0.54
0.97
0.91
0.74
0.55
1.00
0.94
0.77
0.57
1.00
0.95
0.77
0.58
∆T24
2320
1624
2320
1624
2320
1624
2320
1624
2320
1622
2118
15
Hi P
r24
926
828
329
528
030
131
833
131
834
236
137
736
239
041
242
940
743
846
348
345
048
451
153
3
Lo P
r10
711
412
513
311
412
113
214
011
812
613
714
612
413
214
415
313
013
815
116
113
414
315
616
6
3200
MB
h10
7.2
109.
611
7.1
125.
210
4.8
107.
011
4.4
122.
310
2.3
104.
511
1.6
119.
399
.810
1.9
108.
911
6.4
94.8
96.8
103.
511
0.6
87.8
89.7
95.8
102.
5
S/T
0.85
0.80
0.65
0.49
0.88
0.83
0.67
0.50
0.91
0.85
0.69
0.52
0.93
0.88
0.71
0.53
0.97
0.91
0.74
0.55
0.98
0.92
0.75
0.56
∆T26
2522
1727
2522
1827
2522
1827
2622
1826
2522
1825
2421
16
Hi P
r24
226
027
528
627
129
230
832
130
833
235
036
635
137
839
941
639
542
544
946
843
747
049
651
7
Lo P
r10
411
112
112
911
011
712
813
611
412
213
314
212
012
814
014
912
613
414
615
613
013
915
116
1
85
4500
MB
h12
1.8
124.
113
0.0
138.
711
8.9
121.
212
7.0
135.
511
6.1
118.
412
4.0
132.
211
3.3
115.
512
0.9
129.
010
7.6
109.
711
4.9
122.
699
.710
1.6
106.
411
3.5
S/T
0.97
0.94
0.85
0.69
1.00
0.97
0.88
0.71
1.00
1.00
0.90
0.73
1.00
1.00
0.93
0.75
1.00
1.00
0.96
0.78
1.00
1.00
0.97
0.79
∆T24
2422
1924
2423
2024
2423
2023
2423
2022
2223
2020
2121
18
Hi P
r25
427
328
930
128
530
732
433
832
434
936
938
436
939
842
043
841
644
747
249
345
949
452
254
4
Lo P
r11
011
712
713
611
612
313
514
312
012
814
014
912
613
514
715
613
314
115
416
413
714
615
917
0
4000
MB
h11
8.2
120.
512
6.2
134.
711
5.5
117.
712
3.3
131.
511
2.7
114.
912
0.3
128.
411
0.0
112.
111
7.4
125.
310
4.5
106.
511
1.5
119.
096
.898
.710
3.3
110.
2
S/T
0.93
0.89
0.81
0.65
0.96
0.93
0.84
0.68
0.98
0.95
0.86
0.70
1.00
0.98
0.89
0.72
1.00
1.00
0.92
0.75
1.00
1.00
0.93
0.75
∆T25
2523
2025
2524
2126
2524
2125
2524
2124
2424
2022
2322
19
Hi P
r25
227
128
629
828
230
432
133
532
134
636
538
136
639
441
643
341
144
346
848
845
548
951
753
9
Lo P
r10
911
612
613
411
512
213
314
211
912
713
814
712
513
314
515
513
114
015
216
213
614
415
816
8
3200
MB
h10
9.1
111.
211
6.5
124.
310
6.6
108.
611
3.8
121.
410
4.0
106.
111
1.1
118.
510
1.5
103.
510
8.4
115.
696
.498
.310
3.0
109.
889
.391
.195
.410
1.7
S/T
0.89
0.86
0.78
0.63
0.93
0.89
0.81
0.65
0.95
0.92
0.83
0.67
0.98
0.95
0.85
0.69
1.00
0.98
0.89
0.72
1.00
0.99
0.89
0.72
∆T28
2826
2328
2826
2328
2826
2329
2827
2328
2826
2326
2624
21
Hi P
r24
426
327
728
927
429
531
132
531
133
535
436
935
538
240
342
039
943
045
447
344
147
550
152
3
Lo P
r10
511
212
213
011
111
812
913
811
612
313
414
312
112
914
115
012
713
514
815
713
214
015
316
3
IDB
= E
nter
ing
Indo
or D
ry B
ulb
Tem
pera
ture
Des
ign
Sup
erhe
at 7
±2 °
F, D
esig
n S
ubco
olin
g 12
±2
°F p
ress
ures
mea
sure
d @
the
suct
ion
and
liqui
d ac
cess
fi tti
ngs;
AR
I 95°
test
con
ditio
ns
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ctio
n se
rvic
e ac
cess
fi tti
ngs.
Sha
ded
area
refl e
cts
AR
I Rat
ing
cond
ition
s
PRODUCT SPECIFICATIONS
14 www.goodmanmfg.com SS-CPC90-120
DIMENSIONS
ABCD
F
E
I
G
H
J
KL
M
N O PQ
R
S
T
U
V
Downflow Horizontal
W
X Y
Z
Point Dimension(”) Point Dimension
(”)A 3½ N 28⅜B 4½ O 7⅜C 12⅝ P 12⅝D 285/16 Q 5⅞E 4 R 1¾F 54¾ S 36⅜G 3 T 5 H 14 U 15½I 9215/16 V 13⅞J 36⅜ W 4½K 48⅜ X 99¾L 52⅞ Y 99⅛M 613/16 Z 61
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 15
UNIT CLEARANCES
Maintain an adequate clearance around the unit for safety, service, mainten-ance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airfl ow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit Ingestion of exhaust air into the unit’s fresh-air intake.
ELECTRICAL ENTRANCE LOCATIONS
11⅝”
103/16”
3”
Low-Voltage Entrance
High-Voltage Entrance
Dimples Mark Drill Locations
36” Min.
48”
48”75”
48”
PRODUCT SPECIFICATIONS
16 www.goodmanmfg.com SS-CPC90-120
To assist in determining rigging requirements, unit weights are shown to the right.Note: These weights are calculated without accessories installed.
ROOF CURB INSTALLATION — RIGGING
Provisions for forks have been included in the unit base frame. No other fork locations are approved.
Unit must be lifted by the four lifting holes located at the base frame corners.Lifting cables should be attached to the unit with shackles.The distance between the crane hook and the top of the unit must not be less than 60”.Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of suffi cient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to pro-tect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.
Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual.Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofi ng Contractors Association Manual.Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end.Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct.
•
••
•
Corner & Center-of-Gravity Locations
30”
Compressor 1
Return
Evaporator Coil
SupplyCompressor 2
49”
Unit Weights 7½-TonWeights (lbs)
10-TonWeights (lbs)
Weight A 280 285Weight B 280 285Weight C 280 285Weight D 280 285Shipping Weight 1150 1175Operating Weight 1110 1135
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 17
ROOF CURB INSTALLATION (CONT.)Curb installations must comply with local codes and should follow the established guidelines of the National Roofi ng Contractors Association.Proper unit installation requires that the roof curb be fi rmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb.Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for fi eld assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.
Determine suffi cient structural support before locating and mounting the curb and package unit.Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory.
•
•
Contractor furnishes curb insulation, cant strips, fl ashing, and general roofi ng material.Support curbs on parallel sides with roof mem-bers. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings.
Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended.See the manual shipped with the roof curb for assembly and installation instructions.
•
•
TOP VIEW
3-D VIEW
15⅜ x 31⅛Supply Opening
14⅝ x 38⅜Return Opening
92¼ 53¼
14
1⅝¾
14
1⅜
POWER AND LOW-VOLTAGE BLOCK LOCATIONS
Power Wiring
ThermostatWiring
PRODUCT SPECIFICATIONS
18 www.goodmanmfg.com SS-CPC90-120
WIRING DIAGRAM — CPC90/120***B*** (THREE-PHASE/ 460V/ 575V BELT DRIVE)
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
WA
RN
ING
Hig
h V
olt
ag
e:
Dis
con
ne
ct
all
po
we
r b
efo
re s
erv
icin
g o
r in
sta
llin
g t
his
un
it. M
ult
iple
po
we
r so
urc
es
ma
y
be
pre
sen
t. F
ail
ure
to
do
so
ma
y c
au
se p
rop
ert
y d
am
ag
e, p
ers
on
al
inju
ry, o
r d
ea
th.
PRODUCT SPECIFICATIONS
SS-CPC90-120 www.goodmanmfg.com 19
WIRING DIAGRAM — CPC90/120***B*** (THREE-PHASE/ 460V/ 575V BELT DRIVE) CONT.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
WARNING
High Voltage:
Disconnect all power before servicing or installing this unit. Multiple power sources may
be present. Failure to do so may cause property damage, personal injury, or death.
PRODUCT SPECIFICATIONS
20 www.goodmanmfg.com SS-CPC90-120
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifi cations or designs without notice
or without incurring obligations. © 2008 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
ACCESSORIES
Item # Description Fits ModelSizes
Package Dimensions (“)
Ship Weight
14CURB90150 Roof Curb 14” Tall 7½-12½ tons 16 x 6 x 94 160
25FD90150 25% Manual Fresh Air Damper 7½-12½ tons 13 x 15½ x 37½ 11
25MFD90150 25% Motorized Fresh Air Damper 7½-12½ tons 13 x 15½ x 37½ 12
DNSQRRND90 Downfl ow Square-to-Round Adapter 20” Round 7½ tons 15 x 37½ x 10 16
HZECONGS90150 Horizontal Economizer for CPC/CPG 7½-12½ tons 21 x 21 x 48 110
BRD3672 Horizontal Barometric Relief Damper 7½-12½ tons
CDK120 Concentric Duct Kit 10 tons
CDK150 Concentric Duct Kit 12½ tons
CDK90102 Concentric Duct Kit 7½-8½ tons 31 x 48 x 18 55
DNECONGS90150 Downfl ow Economizer for CPC/CPG 7½-12½ tons 40 x 20 x 41 135
HailGD02 Condenser Coil Hail Guard 7½ - 10 tons 64 x 52 x 2
HAKT36300 High-Altitude Kit All Models
HSKT090 High Static Kit 7½ tons
HSKT120 High Static Kit 10 tons
LPKT36150 LP Conversion Kit 3 - 12½ tons