    WSH (Confined space)

    Authorised Manager

    Overall control

    Include any competent person

    Appointed by employer or principal

    (In case that authorized manager cannot perform his

    duties)

    Competent person

    1) Sufficient experience and training to perform

    2) Had passed such courses as commissioner

    required.

    Responsible person

    1) His employer

    2) The principle under a whose he enters or works

    in confined space

    CP Arrangement of regulations?

    CP regulations

    Def: 3 level of hazardous atmosphere

    1) The level of oxygen is not within in the range of

    19.5% to 23.5% by volume

    2) The level of flammable gas and vapour is 10% or

    more of its lower explosive limit (L.E.L)3) The level of toxic substances exceed the

    permissible exposure levels as specified in the

    first schedule of WSH (General Provisions)

    Regulations.

    What is CP any chamber, tank, manhole, vat,

    silo, pit, pipe, flue and any enclose space (in which

    1) dangerous gases, vapours of fumes,

    2) the supply of air is inadequate

    3) risk of engulfment by material)

    Entry ingress by persons into CP, when a

    persons head passes through an open into CP,Duty of responsible person 1) Entrance,

    cover should not remove unless the CP is

    depressurized and render safe for opening.

    2) When entrance cover is removed, to barricade or

    guard by railing (to persent persons or objects falling

    into CP)

    3) Light Sufficient and suitable lighting

    4) Ventilation Adequate & effective from source

    free for contaminants direct to area

    Duty of Occupier of workplace 1) To require

    identification and upkeep of records of all fixed and

    stationary CP in factory.

    2) To inform persons who are liable to expose to

    hazards of CP, the existence and harzards of CP.

    3) To ensure means of entry into and egress from any

    CP are safe and without risks to the health of every

    person entering or leaving the same.

    Evaluation of the need for entry into CP

    Occupier to ensure 1) an evaluation to consider

    the necessity to enter or to carry out work in CP.

    2) A CP entry permit has

    been issued for such entry into CP.

    Implementation of CP entry permitResponsible person to appoint 1) an authorized

    manager

    2) a confined

    space safety assessor

    3) to ensure permit

    to specifies, a) the

    description and

    location of CP, b) the

    purpose of entry, c)

    the result of gas

    testing, d) period of

    validity

    Duty of occupier Warning Sign

    1) To past warning sign at entrance unless a) A

    confined space permit is posted b) No entrance

    which persons may use to enter.

    Duty of Responsible person

    and person entering CP To display name or

    identification badge at entrance to CP.

    Entering a CP without CP entry permit

    1) The person is wearing a suitable breathing

    apparatus

    2) The person has been authorized by authorized

    manager

    3) The person when reasonable practicable iswearing a safety harness with rope securely

    4) CP attendant keeping watch outside attached.

    Training of workers and superiors

    1) Responsible person to ensure (person

    entering or working in CP must first

    received adequate safety and health

    training)

    2) Person conducts oversigh or supervisory

    work must first received adequate safety &

    health training.

    CP attendant 1)Responsible person to appoint

    CP attendantDuty of CP attendant 1) Monitor persons

    entering and working in CP

    2) Maintain regular

    contact with person in CP

    3) Alert rescuer in the erent

    of emergency

    Rescuer operation

    Responsible person to establish

    1) Establish written rescuer plan

    2) Appoint rescuer

    3) Ensure sufficient breathing apparatus, safety

    harness and ropes, suitable for rescuer

    equipment and reviving apparatus a) keep

    readily available, b) Properly maintained, c)

    thoroughly examined by