CP & ED Bdy 0 50 10 5 15 20 25 1. Do not scale from this drawing. 2. All dimensions are in millimeters unless otherwise stated. 3. All dimensions must be checked on site. 4. The designers shall be notified of any discrepancies. 5. This drawing has been produced for sole use on this project and is not intended for use by any other person or any other purpose. Notes: A3 D1007 P02 P01 P02

CP & ED Bdy - Northamptonshire

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

C

P

&

E

D

B

d

y

0 50105 15 20 25

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

A3 D1007 P02

P01

P02

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

A3 D1003 P02

P01

P02

C

P

&

E

D

B

d

y

050105 15 20 25

Proposed Site Plan

PA

PB

Drainage pond

1143 m²

SG

Urea Off Load

District

Heating

connection

Electrical

substation

WASTE

RECEPTION &

PREPARATION

POWER

GENERATION

FUEL

STORAGE

GASIFICATION

PROCESS HALL

CO

ND

EN

SE

RS

CO

ND

EN

SE

RS

Area used for site access

37900

27570853002200014600

80

70

0

E

Existing

landscaping

UP UP

UP

UP

HV/LV Sub-station

Lobby

Corridor

OFFICES, RECEPTION &

AMENITIES

CS

EGT

EGF

FWT FWT

1. This drawing represents the schematic design, and

is subject to detail design development.

2. All waste reception & deliveries will be carried out

within the building.

3. Roof lights are to maximise natural daylight within

the building.

DRAWING NOTES:

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

A3 D1001 P02

P01

KEY:

CS - CYCLE STORE

E - ENTRANCE

EGT - EMERGENCY GENERATOR TURBINE

EGF - EMERGENCY GENERATOR FIRE WATER

PB - PROCESS BACKUP PUMP

PA - PROCESS AUXILIARY

IWB - IN WEIGH BRIDGE

OWB - OUT WEIGH BRIDGE & VEHICLE INSPECTION

FWT - FIRE WATER TANK

P02

52.00 AOD

51.00 AOD

50.00 AOD

49.00 AOD

48.00 AOD

47.00 AOD

46.00 AOD

SIT

E

BO

UN

DA

RY

Site Section 3

49.00 AOD

48.00 AOD

47.00 AOD

46.00 AOD

50.00 AOD

49.00 AOD

48.00 AOD

47.00 AOD

46.00 AOD

49.00 AOD

48.00 AOD

47.00 AOD

46.00 AOD

50.00 AOD

49.00 AOD

48.00 AOD

47.00 AOD

46.00 AOD

51.00 AOD

50.00 AOD

Site Section 2

51.00 AOD

52.00 AOD

50.00 AOD

Site Section 1

51.00 AOD

52.00 AOD

SIT

E

BO

UN

DA

RY

SIT

E

BO

UN

DA

RY

SIT

E

BO

UN

DA

RY

SIT

E

BO

UN

DA

RY

SIT

E

BO

UN

DA

RY

010 252015

CO

NT

IN

UE

S A

BO

VE

CO

NT

IN

UE

S B

EL

OW

1. This drawing represents the schematic design, and

is subject to detail design development.

2. All waste reception & deliveries will be carried out

within the building.

3. Roof lights are to maximise natural daylight within

the building.

DRAWING NOTES:

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

P01

A2

One Didsbury Point, Didsbury, Manchester, M20 2EYTel: 0161 249 1000 Fax: 0161 249 1001

Transfer House, Rankine Ave, Scottish EnterpriseTechnology Park, East Kilbride, G75 0QFTel: 01355 234567 Fax: 01355 266466

88 Glasgow Road, Ratho Station, Newbridge,Edinburgh, EH28 8PPTel: 0131 3353305 Fax: 0131 3353297

2 Lancaster Place, Copse Farm, South Marston Park,Swindon, SN3 4UQTel: 01793 828966 Fax: 01793 828965

Ashmill Business Park, Ashford Road, Lenham,Kent, ME17 2GQTel: 01622 858200 Fax: 01622 850065

D1002 P02

Site section location diagram

P02

ADGMP

010 252015

OFFICES, RECEPTION & AMENITIES

FUEL STORAGEWASTE RECEPTION & PREPARATION GASIFICATION PROCESS HALL POWER GENERATION

Section A-A

Sprinkler pump/fire

Suppression

Lift

Female Change

Store

Lobby

Section B-B

010 252015

+45.00m

Flue stack colour coated to

be Metallic grey

Roller Shutter

Door

Roller Shutter

Door

Roller Shutter

Door

T

GASIFICATION PROCESS HALL

OFFICES, RECEPTION & AMENITIES

GASIFICATION PROCESS HALL

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

A3 D2001 P02

P01

1. This drawing represents the schematic design, and

is subject to detail design development.

2. All waste reception & deliveries will be carried out

within the building.

3. Roof lights are to maximise natural daylight within

the building.

DRAWING NOTES:

P02

OFFICES, RECEPTION & AMENITIES

South East Elevation

District Heating connection in

background with Electrical

substation behind

Aluminium framed curtain walling

system, frame: Dark grey

Site Reception

in foreground

+ 3.00 m

SIT

E

BO

UN

DA

RY

Roller Shutter

Door

010 252015

172264

Escape Doors to be Metallic Grey

Colourcoated metal profiled cladding:

Pale Green - RAL 6021

Rooflights

Photo Voltaic Panels

FFL

50.25 AOD

SIT

E

BO

UN

DA

RY

Existing groundline

(shown dashed)

Roller Shutter Door

Roller Shutter

Door

Roller Shutter

Door

Metal Roller shutter doors:

Mid blue

Metal cladding panels:

Metallic Grey

Projecting frame:

Dark Grey

FUEL STORAGE WASTE RECEPTION & PREPARATIONGASIFICATION PROCESS HALLPOWER GENERATION

+45.00m

Flue stack colour coated to

be Metallic grey

Extract Grilles

North West Elevation

Metal louvred wall system:

Metallic Grey

Escape Doors to be Metallic Grey

Colourcoated metal profiled cladding:

Pale Green - RAL 6021

Rooflights

Photo Voltaic Panels

010 252015

FFL

50.25 AOD

Electrical substation with

District Heating connection

behind

Site Reception

in background

+ 3.00 m

SIT

E

BO

UN

DA

RY

SIT

E

BO

UN

DA

RY

Existing groundline

(shown dashed)

Roller Shutter DoorRoller Shutter DoorRoller Shutter Door

172264

PROCESS HALLFUEL STORAGEWASTE RECEPTION & PREPERATION POWER GENERATIOJN

+45.00m

Flue stack colour coated to

be Metallic grey

Extract Grilles

Metal cladding panel:

Metallic Grey

Metal fascia:Dark Grey

Site Reception

SIT

E

BO

UN

DA

RY

North East Elevation

Roller Shutter Door

SIT

E

BO

UN

DA

RY

Extract Grilles

Metal Roller shutter doors:

Mid blue

Grille:

Mid blue

Personell/Escape

Door:

Mid blue

Roller Shutter Door

Existing ground line

(shown dashed)

010 252015

+45.00m

Flue stack colour coated to

be Metallic grey

Roller Shutter

Door

80340

South West Elevation

Metal Cladding panles: Metallic

Grey, with frame/ trim in Mid Grey

SIT

E

BO

UN

DA

RY

SIT

E

BO

UN

DA

RY

Existing groundline

(shown dashed)

Metal cladding panel:

Metallic Grey

Metal fascia:Dark Grey

+45.00m

Flue stack colour coated to

be Metallic grey

Extract Grille

Personell/Escape Door:

Mid blue

Roller Shutter

Door

Roller Shutter

Door

010 252015

Fire water tank

Site Reception

background

A1

One Didsbury Point, Didsbury, Manchester, M20 2EYTel: 0161 249 1000 Fax: 0161 249 1001

Transfer House, Rankine Ave, Scottish EnterpriseTechnology Park, East Kilbride, G75 0QFTel: 01355 234567 Fax: 01355 266466

88 Glasgow Road, Ratho Station, Newbridge,Edinburgh, EH28 8PPTel: 0131 3353305 Fax: 0131 3353297

2 Lancaster Place, Copse Farm, South Marston Park,Swindon, SN3 4UQTel: 01793 828966 Fax: 01793 828965

Ashmill Business Park, Ashford Road, Lenham,Kent, ME17 2GQTel: 01622 858200 Fax: 01622 850065

D2000 P02

1. This drawing represents the schematic design, and

is subject to detail design development.

2. All waste reception & deliveries will be carried out

within the building.

3. Roof lights are to maximise natural daylight within

the building.

DRAWING NOTES:

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

P01

P02

UP

UP

UP

UP

HV/LV Sub-station

Reception

Co

rrid

or

Store

Switch room

Sprinkler pump/fire

Suppression

G H I JK

Escape

Stair

L

Lift

DN

DN

UP

CONTROL

ROOM

Open Plan

Office

FEMALE

CHANGE

MALE CHANGE

CANTEEN

AC

CE

SS

IB

LE

WC

/C

HA

NG

E

STORE

LOBBY

Lift

CONFERENCE/

EDUCATION SUITE

Sun tunnels & internal vision panels

to provide light to level 01 rooms

G H I JK

L

1. This drawing represents the schematic design, and

is subject to detail design development.

2. All waste reception & deliveries will be carried out

within the building.

3. Roof lights are to maximise natural daylight within

the building.

DRAWING NOTES:

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

A3 D1005 P02

P01

LEVEL 01

Office, Education & Staff Facilities

LEVEL 00

Reception Lobby & Services Distribution

P02

UP

UP

UP

UP

HV/LV Sub-station

Reception

Co

rrid

or

Store

Switch room

Sprinkler pump/fire

Suppression

A B C D E F G H I J K M N O P

9500 9500 9500 9500 9500 9500 9500 9500 9500 9500 8600

Pass through 1

Fly Ash Room

5MW Turbine Room

Pass through 2

10MW Turbine Room

Stack Room

Hazardous Waste

Store

Sample Store

Urea RoomWorkshop

Escape

Stair

Ash Handling Bay

L

Standby Generator

Room

Crane Grab

Maintanence 02

Crane Grab

Maintanence 01

Lift

GASIFICATION

PROCESS

HALL

FUEL

STORAGE

WASTE

RECEPTION

&

PREPARATION

8950

Q

9500

R

9500

S

9500

T

9500725072507250

1. This drawing represents the schematic design, and

is subject to detail design development.

2. All waste reception & deliveries will be carried out

within the building.

3. Roof lights are to maximise natural daylight within

the building.

DRAWING NOTES:

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

A3 D1004 P02

P01

P02

ROOF PLAN

A

B

B

RL

PV

RL

Colourcoated Metal profiled cladding:

Pale Green - Ral 6021.

Rainwater gutter

Metal standing seam roof:

Mid metallic grey

Rainwater gutter

PV = Photovoltaic Panels

RL = Rooflight

Face of building

below

Total area 1615m²

010 252015

A

1. Do not scale from this drawing.

2. All dimensions are in millimeters unless otherwise stated.

3. All dimensions must be checked on site.

4. The designers shall be notified of any discrepancies.

5. This drawing has been produced for sole use on this project and

is not intended for use by any other person or any other purpose.

Notes:

A3 D1006 P02

P01

P02