7
FILTRATION TURBINE OIL COALESCE SKIDS REMOVE HARMFUL WATER & ACHIEVE LOWER THAN TARGET ISO CODES COT Remove Free & Emulsified Water to Below 150 PPM / 0.0150% Rapid removal of free water in high concentrations (steam, cooler leak) High Efficiency Particulate Filtration Digitally adjustable Low Watt Density Heaters optional for system start-up Dimensional and Arrangement Design Flexibility Automatic Water Drain Circuit solid state sensors (no moving parts) Electrical Phase Reversal Standard Smart Relay Controlled Panel Yields Easy & Reliable Operation Before After www.hyprofiltration.com

COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

FILTRATION

TURBINE OIL COALESCE SKIDSREMOVE HARMFUL WATER & ACHIEVE LOWER THAN TARGET ISO CODES

COT

• RemoveFree&EmulsifiedWatertoBelow150PPM/0.0150%

• Rapidremovaloffreewaterinhighconcentrations(steam,coolerleak)

• HighEfficiencyParticulateFiltration

• DigitallyadjustableLowWattDensityHeatersoptionalforsystemstart-up

• DimensionalandArrangementDesignFlexibility

• AutomaticWaterDrainCircuitsolidstatesensors(nomovingparts)

• ElectricalPhaseReversalStandard

• SmartRelayControlledPanelYieldsEasy&ReliableOperation

Before After

www.hyprofiltration.com

Page 2: COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

High Efficiency Coalescence Combined with High Efficiency ParticulateFiltration Keep Turbine Oil Clean, Dry and Healthy!

COT10AutoAirBleedVentValve

Multi-ElementCoalesce&SeparatorHousing

CoalesceVesselBypassLoop

Davit&SwingArmLidSupport

NEMA4ControlPanel

Coalesce&Pre-FilterVesselsEquippedWithTrueGreentoRedDPGauges

PressureandDifferentialPressureGaugePanel

3-WayBypassLineSelectorValve

Coalesceelementfeatures100%syntheticmedia(nocellulosemediareducingcompatibilityrelatedelementfailures).

Dual-stageseparatorandpolishingfilterelementfeatureswaterbarrierandhighefficiencyglassmediapost-filtration.

Highefficiencycorelesspre-filteryieldslowerthantargetISOFluidCleanlinessCodeswhileextendingcoalesceelementlife!

www.hyprofiltration.com

Page 3: COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

COT

InletconnectionwithICVvalve(NormallyclosedSolenoid)

Outletconnection(Returntoreservoir)

Serviceplatforms

Multi-elementcoalesce&separatorhousing

Highflowpre-filterwithcorelessfilterelement(topload)

Lowwattdensityheater

Gearpump

Lowwattdensityheater

Driptraywithforkliftguides

Coalescevesselbypassline

Specificgravityfloatlevelsensor

Sightglass

www.hyprofiltration.com

Page 4: COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

The Harmful Affects of Water in OilWaterisoneofthemostcommonandmostdamagingcontaminantsfoundinalubeorhydraulicsystem.Continuousorperiodichighwaterlevelscanresultindamagesuchas:

• MetalEtching(Corrosion)

• AbrasiveWearinHydraulicComponents

• DielectricStrengthLoss

• FluidBreakdown• AdditivePrecipitation

andOilOxidation• ReductioninLubricating

Properties

75% of Hydraulic & Lube Component failures are Caused by ContaminationTheeffectsofmoistureinyouroilsystemscandrasticallyreduceon-streamplantavailability.Bearinglifeandcriticalcomponentlifeisgreatlyreducedbymoisturelevelsaboveandwithinthesaturationpoint.Manysystemsrunconstantlyabovethispointduetoinefficientdehydrationtechnologiesandhighingression.Thisdevelopsacidityandlossoflubricationproperties.Freewateroccurswhenoilbecomessaturatedandcannotdissolveanyadditionalwater.Thiswatermakestheoilappearcloudyandcanevenbeseeninpuddleformatthebottomofareservoir.Waterwhichisabsorbedintotheoiliscalleddissolvedwater.Atelevatedtemperatures,oilhastheabilitytoholdmorewaterinthedissolvedstateduetotheexpansionoftheoilmolecules.Astheoilcools,itlosesitscapacitytoholdwaterandfreewaterwillappearwherepreviouslynotvisible.Fluidtypealsodeterminessaturationpointinadditiontotemperaturechanges.

1000(0.1%) 500(0.05%) 250(0.025%) 100(0.01%) 50(0.005%)RollingElement

JournalBearing

RollingElement

JournalBearing

RollingElement

JournalBearing

RollingElement

JournalBearing

RollingElement

JournalBearing

5000 2.3 1.6 3.3 1.9 4.8 2.3 7.8 2.9 11.2 3.52500 1.6 1.3 2.3 1.6 3.3 1.9 5.4 2.4 7.8 2.91000 1.4 1.2 2 1.5 3.3 1.9 4.8 2.3500 1.4 1.2 2.3 1.6 3.3 1.9250 1.5 1.3 2.3 1.6100 1.4 1.2

NewMoistureLevelPPM(%)

CurrentM

oistureLevelPPM

*CourtesyofNoria

ComponentLifeExtensionbyRemovingWater*

www.hyprofiltration.com

Page 5: COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

COT

Intuitive Design Makes Hy-Pro Skids Easy to Operate.Operator Friendly Smart Relay - Smartrelayenabledcontrolpanelperformscontrolledstart-up&shut-downroutinesforeaseofoperationandkeepsoperatorsoutofthecontrolbox.Includesmachinedrainsequence&automaticphasereversal(internallycontrolled,noguessworkorswitchtothrow).Systemstatusisreportedwithilluminatedlightsorsequencesofflashinglights.

Variable Frequency Drive Speed Control (Optional) - VFDcontrolledvariablespeedoptimizescoalesceefficiencyrelativetofluidtemperaturebyrunningsloweruntiloptimumoiltemperatureisachieved.Idealforhighflowsystems(i.e.100gpm)whereVFDcanbeusedtoprovideagradualstart.Smartrelaycanbeprogrammedtotaketemperaturesensorinputandautomaticallyadjustflowforoptimumperformance.

Feature Description

CommonSystemDrain Allvesselsandheaterhousingscanbedrainedthroughacommondrain(lowestpoint).

EasyAccessSamplePorts Monitoroilconditionwithsampleportslocatedbeforethepre-filterandafterthecoalescestage.

SafeServicePlatform Retractablegridforeasyaccesstoserviceablecomponents.

HeaterSystem Lowwattdensityheaterspreventcoking.Nodirectheatelementcontactwithoil.Heatappliedonlywhenneeded.

HighSinglePassEfficiency Highefficiencymediadesignyields95%singlepasswaterremovalefficiencyat5000ppm.

AutoWaterDrain Idealforcontinuousandunattendedoperation.Maximizesuptime(24/7operation).

GravityFloatLevelControlAutodrainandhighwatersensorleveldetectionbasedonthermalconductivityoffluid(solidstateprobes).Nomovingpartstofailorservice.

FlexibleDesign&Dimensions Flexibledimensionsandprocessarrangementtosuityourapplication(Welistentowhatyouwant).

PleatedCoalesceElement(allsyntheticmedia)

Pleatedcoalesceelementsyieldmoreefficientwatercoalescethantraditionalwrappedbundesigns.

CombinationPost-Filter&SeparatorElement(allsyntheticmedia)

HighefficiencypleatedglasspostfilterwithinnovativeseparatorsleeveknocksoutwaterandconsistentlydeliverslowerISOcleanlinesscodes.

True DPGaugeswithGreentoRedDisplay

TruegreentoredDPgaugesprovidevisualconditioncheckandcontrolpanelsignal.Sensorsarelocatedinthevesselsformostaccurateelementconditionmonitoring.

LongerElementLife Coalesceandseparatorroutinechangeinterval1yearorchangeonelementDPindicationforcontaminatedsystems.

CorelessPre-filter Corelesspre-filterelementfeaturesb5[c]>1000efficiencyandintegralbypassvalve(newvalvewitheachelementchange).

TotalizingWaterMeter(optional) Trackamountofwaterremovedfromthesystemwithoptionaltotalizingwatermeter(canbeintegratedintooptionalPLC).

www.hyprofiltration.com

Page 6: COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

TURBINE OIL COALESCE SKID SPECIFICATIONS & SIZING

Model Length Inch (mm)

Width Inch (mm)

Height Inch (mm)

Weight Lbs (Kg)

InletSize

(Female Pipe Port)

OutletSize

(Female Pipe Port)

Motor Size

COT5 56(1423) 32(813) ~72(1828) ~875(~397) 1.5” 1” 1HP

CO10 60(1524) 40(1016) ~80(2032) ~1600(~726) 1.5” 1” 1.5HP

COT30 84(2134) 40(1016) ~90(2286) ~1600(~726) 2” 1.5” 5HP

COT60 84(2134) 40(1016) ~90(2286) ~3500(~1588) 3” 2” 5HP

COT100 84(2134) 40(1016) ~90(2286) ~3500(~1588) 3” 2” 10HP

COT Filter Elements Utilized by Model*Model Pre-Filter

ElementsCoalesce Elements

Separator/Polish Elements

COT5 1 1XHP677L39-3MV* (CombinedElement)COT10 1 2xHP731L39-CB 1xHP582L30-S1MBCOT30 1 5xHP731L39-CB 3xHP582L30-S1MBCOT60 2 8xHP731L39-CB 5xHP582L30-S1MBCOT100 3 8xHP731L39-CB 5xHP582L30-S1MB

*HP677L39-3MVcombinescoalesceandseparatorelementfunctionsintooneelement

COT Turbine Oil Model Sizing RecommendationsModel Maximum Reservoir VolumeCOT5 800GallonsCOT10 1600GallonsCOT30 4000GallonsCOT60 8000GallonsCOT100 13250Gallons

www.hyprofiltration.com

Page 7: COT TURBINE OIL COALESCE SKIDS · All vessels and heater housings can be drained through a common drain (lowest point). Easy Access Sample Ports Monitor oil condition with sample

COTWATER & PARTICULATE REMOVAL PERFORMANCE

Element Synergy - DFEratedG8Dualglasspre-filterremovesparticulatebeforeenteringthecoalescevesselwithhighefficiencyb5[c]>1000media.Oilentersthetwostagevesselpassingfirstthroughthecoalesceelementswherewaterdropletsformandfall.Inthesecondstageofthecoalesceprocessoilpassesthroughthecombinationseparator/polishelementwheretheremainingwaterdropletsareblockedthenfalltothebottomofthecoalescevesseltobeejectedbytheauto-waterdraincircuit.Theseparator/polishelementsalsofeatureb2.5[c]>1000G8Dualglassmediacreatingtwopassesthroughhighlyefficientglassmediaelements.

A properly sized Hy-Pro Coalesce Skid will deliver turbine reservoir cleanliness codes of 15/13/10 and better. Maintain water levels at or slightly below a typical saturation level of 150 ppm.

Coalesce Elements HP731L39-CB (No Cellulose) - Hy-ProCoalesceelementscontainnocellulosemediawhichcanbeattackedbyhighwatercontentresultinginmediamigrationandalossofcoalescenceefficiency.Threadedendcaplocksintothehousingwithoutanywashers,screws,ornutstodropintothebottomofthecoalescevessel.Thepleatedsyntheticconfigurationmaximizessurfaceareaandiscontainedbyarigidsupporttube.Therearenowrappedouterlayerstogetsoggyandshedfibersintotheoil.

Separator - Polishing Elements (No Cellulose) HP582L30-S1MB - Awaterseparatingouterwrapknocksoutremainingwaterdropletswhichshedtothebottomofthereservoir.ThepleatedG8DualglassmediapackdownstreamofthewaterbarrierremovessolidcontaminanttoyieldsupercleananddryfluidleavingtheHy-Procoalesceskid.

The b2.5[c] > 1000 final element also reduces thepopulation of sub-micronic insoluble particles thatcontribute to microbial growth and abrasive wear.

High Water Ingression - Commonsourcesofgrosswatercontaminantincludeseal,steamandheatexchangerleaks.Hy-Procoalesceskidsefficientlyremovehighquantitiesofgrosswaterthatcanbepresentduringwaterleaks.AvoidunplannedshutdownsduetoturbinelubesystemwaterleaksbyremovinggrosswaterwithaHy-Procoalesceskidandkeepoperatinguntilthenextplannedoutage.

COT30

COT5

Before After

www.hyprofiltration.com