Copyright © 2001 Praxis Critical Systems Limited
Copyright © 2001 Praxis Critical Systems Limited
RTCA DO-178B: Software Considerations in Airborne Systems and Equipment Certification
• Industry-produced guidelines– Consensus document for avionics software good practice
– Not a process document
– Not a standard
• Theoretically provides guidelines• In practice:
– Endorsed by the FAA and JAA
– The “Bible” for civil avionics software certification
• Compliance established by ders– Compliance here means process compliance
Copyright © 2001 Praxis Critical Systems Limited
Criticality Levels
• Levels assigned according to consequence of failure– Level A: catastrophic
– Level B: hazardous/severe-major
– Level C: major
– Level D: minor
– Level E: no effect
• DO-178B processes vary according to level• Only A & B likely to be regarded as safety-
critical
Copyright © 2001 Praxis Critical Systems Limited
Verification Activities
• For each development output standard either requires:– Tool that produced that output to be qualified; or
– The output itself to be verified
• Since most tools in the object code generation path are not qualified – The object code itself must be verified
– Achieved by specified test coverage criteria
– Coverage can be of object code itself or of source code if source-to-object traceability can be achieved
Copyright © 2001 Praxis Critical Systems Limited
Tool Qualification
• Software development tools– Tools whose output forms part of the airborne software (e.g.
Compiler)
• Software verification tools– Tools which cannot introduce errors but may fail to detect
them (e.g. Static analyser)
• Qualification of tools essentially requires tool to be developed to same standard as system on which it will be used
Copyright © 2001 Praxis Critical Systems Limited
Test Coverage Requirements
• Level A: MC/DC branch coverage– Modified decision/condition coverage
• Level B: branch (decision) coverage
• Level C: statement coverage
• Level D/E: no specific requirements
Copyright © 2001 Praxis Critical Systems Limited
What Is MC/DC?
if A and B then
X = X + 1;
elsif C or D then
Y := Y + 1;
end if;
Decision coverage - each branch/path is executed
3 test cases
(A B)
(A B)^(C D)
(A B)^ (C D)
Condition coverage - each value affecting decision is executed
16 test cases
A B C DA B C D A B C D A B C D
Modified Condition coverage - each value independently affecting decision is executed
4 test cases
any 1 of
Copyright © 2001 Praxis Critical Systems Limited
Establishing Coverage
Copyright © 2001 Praxis Critical Systems Limited
Coverage Analysis
• Show that coverage required for level has been achieved
• Confirm the data- and control-flow couplings between components
• Coverage analysis can take place at source level unless:– The code is level A; and
– The object code is not directly traceable from the source code
• e.g. An Ada run-time check
Copyright © 2001 Praxis Critical Systems Limited
Inadequate Coverage
• Shortcomings in requirements-based test cases– Add more tests
• Inadequate requirements– Modify requirements, add more tests as necessary
• Dead code (always semantically infeasible)– Remove, reverify if necessary
• Deactivated code– Show that code cannot be called in delivered configuration; or
– force test cases to execute it
Copyright © 2001 Praxis Critical Systems Limited
Coverage “Cheating”
function IsRed return Boolean is begin return True;end IsRed;
function IsBig return Boolean is begin return False;end IsBig;
function IsEdible return Boolean isbegin return True;end IsEdible;
Properties of a Tomato
3 tests required
Copyright © 2001 Praxis Critical Systems Limited
Coverage “Cheating”
type Properties is (Red, Big, Edible)
Tomatoes constant : array(properties... := (Red => True, Big => False, Edible => True);
function GetProperty (P : Properties) return Boolean is begin return Tomatoes (P);end GetProperty;
Properties of a Tomato
1 test required
Copyright © 2001 Praxis Critical Systems Limited
DO-178B Critique
• Software correctness standard not a system safety standard– Cannot construct arguments to show how hazards are mitigated
– Can only state “whole box done to level A”
• Undue emphasis on test– Little or no credit for worthwhile activity such as analysis and reviews
– Can create an environment where getting to test quickly is seen as the prime aim
– MC/DC widely misinterpreted as “exhaustive” testing
– Deactivated code issues create problems for “good” languages like Ada
• DER role is establishing process compliance not system safety
Copyright © 2001 Praxis Critical Systems Limited
Economic Arguments
• DO-178B gives little credit for anything except testing
• The required testing is harder for Ada than C• Therefore the best solution is to “hack in C”?
No!
• MC/DC testing is very expensive– some estimates say x5 cost– needs test rig: back-end, high-risk process
• Therefore processes that reduce errors going into formal test are very worthwhile
Copyright © 2001 Praxis Critical Systems Limited
C130J Development Process - Principles
• Emphasis on correctness by construction (CbC)– Focus on “doing it right first time”
– Verification-driven development
– Requirements of DO-178B kept in mind but not allowed to dominate
• “Formality” introduced early– In specification
– In programming language
• Application domain rather than solution domain focus– e.g. Identification of common paradigms
• Risk management– e.g. “Thin-slice” prototyping
Copyright © 2001 Praxis Critical Systems Limited
Requirements and Specification
• CoRE (consortium reqts engineering)– Parnas tables to specify input/output mappings
• Close mapping between CoRE requirements and code for easy tracing
• Functional test cases obtain from CoRE tables
Copyright © 2001 Praxis Critical Systems Limited
CoRE Elements
EnvironmentInput
DevicesOutputDevices
Software Environment
System Input
Data
Items
Output
Data
Items
Monitored
Variables
Controlled
Variables
IN SOFT OUT
Copyright © 2001 Praxis Critical Systems Limited
REQ Template
MON MON CON
<value orrange>
<value orrange>
<f(MONs,TERMs) or
value>
Copyright © 2001 Praxis Critical Systems Limited
CoRE REQ Example
<engine>Fuelcp_mon_auto_xfer_class
Fuelcp_mon_transfer_method
<engine>fuelcp_mon_xfeed_class
<engine>fmcs-con_ fuel_control_valve_class
X X from | off shut
X manual to open
< <engine>fmcs_mon_fuel_level_tank_class
auto to open
>= <engine>fmcs_mon_fuel_level_tank_class
auto to shut
Copyright © 2001 Praxis Critical Systems Limited
Implementation
• Close mapping from requirements: “one procedure per table”
• Templates for common structures– e.g. Obtaining raw data from bus and providing abstract
view of it or rest of system (“devices”)
• Coding in SPARK (150K SLOC)• Static analysis as part of the coding process
Copyright © 2001 Praxis Critical Systems Limited
An Unexpected Benefit of SPARK
• SPARK requires all data interactions to be described in annotations
• Some interactions were not clearly specified in the CoRE tables– e.g. Validity flags
• Coders could not ignore the problem• Requirements/specification document became a
“live”, dynamic document as ambiguities were resolved during coding
Copyright © 2001 Praxis Critical Systems Limited
Integrated Formality
CoRE Specification
SPARK Code
Test Cases
Static Analysis Testing
Templates
Copyright © 2001 Praxis Critical Systems Limited
Example - an Aircrew Warning System
A specification for this function might be:
mon_Event con_Bell
Warning TrueCaution TrueAdvisory False
type Alert is (Warning, Caution, Advisory);
function RingBell(Event : Alert) return Booleanis Result : Boolean;begin if Event = Warning then Result := True; elsif Event = Advisory then Result := False; end if; return Result;end RingBell;
An (incorrect) implementation might be:
The Value of Early Static Analysis
Copyright © 2001 Praxis Critical Systems Limited
Example Contd. - Test Results
• There is a very high probability that this code would pass MC/DC testing • The code returns True correctly in the case of Event=Warning and False
correctly in the case of Event=Advisory• In the case of Caution it returns a random value picked up from memory;
however, there is a very high probability that this random value will be non zero and will be interpreted as True which is the expected test result
• The test result may depend on the order the tests are run (testing Advisory before Caution may suddenly cause False to be returned for example)
• The results obtained during integration testing may differ from those obtained during unit testing
Copyright © 2001 Praxis Critical Systems Limited
Example Contd. - Examiner Output
13 function RingBell(Event : Alert) return Boolean 14 is 15 Result : Boolean; 16 begin 17 if Event = Warning then 18 Result := True; 19 elsif Event = Advisory then 20 Result := False; 21 end if; 22 return Result; ^1??? ( 1) Warning : Expression contains reference(s) to variable Result, which may be undefined.
23 end RingBell;
??? ( 2) Warning : The undefined initial value of Result may be used in the derivation of the function value.
Copyright © 2001 Praxis Critical Systems Limited
The Lockheed C130J and C27J Experience
• The testing required by DO-178B was greatly simplified:– “Very few errors have been found in the software during
even the most rigorous levels of FAA testing, which is being successfully conducted for less than a fifth of the normal cost in industry”
• Savings in verification are especially valuable because it a large part of the overall cost– “This level A system was developed at half of typical cost
of non-critical systems”
• Productivity gains:– X4 on C130J compared to previous safety-critical projects– X16 on C27J with re-use and increased process maturity
Copyright © 2001 Praxis Critical Systems Limited
C130J Software Certification
C130J
Civil
Military
DO-178B/FAA
RAF leadcustomer
UK MoD IV&Vprogramme
comparisons
Copyright © 2001 Praxis Critical Systems Limited
UK Mod IV&V Programme
• The UK mod commissioned aerosystems international to perform retrospective static analysis of all the C130J critical software
• A variety of tools used: e.g.– SPARK examiner for “proof” of SPARK code against CoRE
– MALPAS for Ada
• All “anomalies” investigated and “sentenced” by system safety experts
• Interesting comparisons obtained
Copyright © 2001 Praxis Critical Systems Limited
Aerosystems’ IV&V Conclusions
• Significant, safety-critical errors were found by static analysis in code developed to DO-178B Level A
• Proof of SPARK code was shown to be cheaper than other forms of semantic analysis performed
• SPARK code was found to have only 10% of the residual errors of full Ada and Ada was found to have only 10% of the residual errors of C
• No statistically significant difference in residual error rate could be found between DO-178B Level A, Level B and Level C code
Copyright © 2001 Praxis Critical Systems Limited
Language Metrics
SLOCs/Anomaly
BA
U I
I
FM
CS
GC
AS
BA
EC
S
NIU
FO
D
DA
DS
EC
BU
HU
D IDP
HU
D
0
50
100
150
200
250
300
Ada
Assembler
LUCOL
SPARK Ada
C
PLM
Ave
rag
e
SLO
C p
er
anom
aly
1% have safety implications
Copyright © 2001 Praxis Critical Systems Limited
Resources
• RTCA-EUROCAE: Software Considerations in Airborne Systems and Equipment Certification. DO-178B/ED-12B. 1992.
• Croxford, Martin and Sutton, James: Breaking through the V&V Bottleneck. Lecture Notes in Computer Science Volume 1031, 1996, Springer-Verlag.
• Software Productivity Consortium. www.software.org
• Parnas, David L: Inspection of Safety-Critical Software Using Program-Function Tables. IFIP Congress, Vol. 3 1994: 270-277
• Sutton, James: Cost-Effective Approaches to Satisfy Safety-critical Regulatory Requirements. Workshop Session, SIGAda 2000
• German, Andy, Mooney, Gavin. Air Vehicle Static Code Analysis - Lessons Learnt. In Aspects of Safety Management, Redmill & Anderson (Eds). Springer 2001. ISBN 1-85233-411-8
Copyright © 2001 Praxis Critical Systems Limited
Programme
• Introduction• What is High Integrity Software?• Reliable Programming in Standard Languages
– Coffee
• Standards Overview• DO178B and the Lockheed C130J
– Lunch
• Def Stan 00-55 and SHOLIS• ITSEC, Common Criteria and Mondex
– Tea
• Compiler and Run-time Issues• Conclusions
Copyright © 2001 Praxis Critical Systems Limited
Programme
• Introduction• What is High Integrity Software?• Reliable Programming in Standard Languages
– Coffee
• Standards Overview• DO178B and the Lockheed C130J
– Lunch
• Def Stan 00-55 and SHOLIS• ITSEC, Common Criteria and Mondex
– Tea
• Compiler and Run-time Issues• Conclusions
Copyright © 2001 Praxis Critical Systems Limited
Outline
• UK Defence Standards 00-55 and 00-56– What are they?
– Who’s using them?
• Main Principles & Requirements
• Example Project - the SHOLIS
Copyright © 2001 Praxis Critical Systems Limited
Defence Standards 00-55 and 00-56
• “Requirements for Safety related Software in Defence Equipment” UK Defence Standard 00-55– Interim issue 1991
– Final issue 1997
• “Safety Management Requirements for Defence Systems” UK Defence Standard 00-56, 1996
• Always used together
Copyright © 2001 Praxis Critical Systems Limited
Who’s using 00-55 and 00-56
• Primarily UK-related defence projects
• SHOLIS (more of which later…)• Tornado ADV PS8 MMS• Harrier II SMS• Ultra SAWCS• Lockheed C130J (via a mapping from DO-178B)
• Has (sadly) little influence in the USA
Copyright © 2001 Praxis Critical Systems Limited
UK MOD 00-56
• System-wide standard• Defines the safety analysis process to be used
to determine safety requirements, including SILs
• SILs are applied to components
• Promotes an active, managed approach to safety and risk management
Copyright © 2001 Praxis Critical Systems Limited
Def. Stan. 00-56 Main Activities
CorrectiveAction
Hazard Log
Safety CaseConstruction
SafetyRequirements
SafetyProgramme
Plan
HazardIdentification
andRefinement
RiskEstimation
SafetyComplianceAssessment
SafetyVerification
Copyright © 2001 Praxis Critical Systems Limited
UK Defence Standard 00-55
• Applied to software components of various SILs• Defines process and techniques to be followed
to achieve level of rigour appropriate to SIL• A Software Safety Case must be produced:
– to justify the suitability of the software development process, tools and methods
– present a well-organized and reasoned justification based on objective evidence, that the software does or will satisfy the safety aspects of the Software Requirement
Copyright © 2001 Praxis Critical Systems Limited
00-55: Software Development Methods
Technique/Measure SIL2 SIL4
Formal Methods J1 M
Structured Design J1 M
Static Analysis J1 M
Dynamic Testing M M
Formal Verification J1 M
M = “Must be applied”
J1 = “Justification to be provided if not followed.”
Copyright © 2001 Praxis Critical Systems Limited
Comparison With DO-178B
• RTCA DO-178B– MC/DC testing
– Comparatively little about process
– Level A to level E
– Focus on software correctness
• Def Stan 00-55– Heavy emphasis on formal methods & proof
– Still stringent testing requirements
– S1 to S4
– Focus on software safety
Copyright © 2001 Praxis Critical Systems Limited
00-55 and Independent Safety Audit
• 00-55 requires a project to have an Independent Safety Auditor (ISA)
• At SIL4, this engineer must be from a separate, independent company from the developers.
• The ISA carries out:– Audit - of actual process against plans
– Assessment - of product against safety requirements
• ISA has sign-off on the safety-case.• Compare with role of DO-178B DER.
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS
• The Ship/Helicopter Operating Limits Instrumentation System.
• Assesses and advises on the safety of helicopter flying operations on board RN and RFA vessels.
• Ship/Helicopter Operating Limits (SHOLs) for each ship/helicopter/scenario in a database.
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS - The Problem
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS background
• Power Magnetics and Electronic Systems Ltd. (now part of Ultra Electronics Group) - Prime Contractor.– System architecture and Hardware. (NES 620)
• Praxis Critical Systems Ltd. - all operational software to Interim Def-Stan. 00-55 (1991)
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS block diagram
FDDU
BDU
DPU1
DPU2
CLM
ABCB
Ship’s Data Bus and UPSs
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS LRUs
• DPU1, DPU2 - Data Processing Units.
• BDU - Bridge display unit
• FDDU - Flight-deck display unit
• CLM - Change-over logic module
• ABCB - Auxiliary Bridge Control Box
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS FDDU on test...
• © Ultra Electronics 1999
Copyright © 2001 Praxis Critical Systems Limited
Fault tolerance
• Fault tolerance by hot-standby.
• Only one DPU is ever actually controlling the displays.
• CLM is high-integrity H/W, and selects which DPU is “selected” but ABCB switch can override choice.
• DPUs run identical software and receive same inputs.
Copyright © 2001 Praxis Critical Systems Limited
Fault tolerance(2)
• Unselected DPU outputs to display, but display simply ignores the data.
• DPUs are not synchronised in any way - both run free on their own clock source.
• DPUs at either end of ship in case one becomes damaged.
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS history
• Phase 1– Prototype demonstrating concept, U/I and major S/C
functions. Single DPU and display. Completed 1995
• Phase 2– Full system. Software to Interim Def-Stan. 00-55.
Commenced 1995.
• Trials– Autumn 1998 onwards
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS software - challenges
• First system to Interim DS 00-55– Many risks:
• Scale of Z specification
• Program refinement and proof effort
• Complex User-Interface
• Real-time, fault-tolerance and concurrency
• Independent V&V and Safety Authority.
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS - Exceptions from Interim 00-55
• A very small number of exceptions from 00-55:
• No formal object code verification (beyond state of art?)
• No diverse proof checker (no such tool!)
• No “back-to-back” test against an “executable prototype” (what does this mean?)
Copyright © 2001 Praxis Critical Systems Limited
Software process (simplified)
Requirements
English
SRS
Z & English
SDS: SPARK Z, English
Code
SPARK
Copyright © 2001 Praxis Critical Systems Limited
Documents
• Requirements - over 4000 statements, all numbered.
• SRS - c. 300 pages of Z, English, and Maths.• SDS - adds implementation detail: refined Z
where needed, scheduling, resource usage, plus usual “internal documentation.”
Copyright © 2001 Praxis Critical Systems Limited
The code...
• Approx. 133,000 lines:• 13,000 declarations
• 14,000 statements
• 54,000 SPARK flow annotations
• 20,000 SPARK proof annotations
• 32,000 comment or blank
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS Z specification - example
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS code - example - specification
---------------------------------------------------------------- -- Up10
--
-- Purpose:
-- Incrementally cycles the tens digit of the given integer.
--
-- Traceunit: ADS.InjP.Up10.SC
-- Traceto : SDS.InjP.Up10.SC
---------------------------------------------------------------
function Up10 ( I : in InjPTypes.HeadingValTypeT )
return BasicTypes.Natural32;
--# return Result =>
--# (((I/10) mod 10) /= 9 -> Result = I+10) and
--# (((I/10) mod 10) = 9 -> Result = I-90) and
--# Result in BasicTypes.Natural32;
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS - code example - body
-- Worst case serial chars : 0; -- Worst case time (est) : 4*LINES;
--
-- Traceunit: ADB.InjP.Up10.SC
-- Traceto : SDS.InjP.Up10.SC
--------------------------------------------------------------------
function Up10 ( I : in InjPTypes.HeadingValTypeT )
return BasicTypes.Natural32
is
R : BasicTypes.Natural32;
begin
if ((I/10) mod 10) /= 9 then
R := I+10;
else
R := I-90;
end if;
return R;
end Up10;
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS code example - proof
• Up10 gives rise to 5 verification conditions - 3 for exception freedom (can you spot them all?!) and 2 for partial correctness.
• The SPADE Simplifier proves 3 of them automatically.
• The remaining 2 depend on knowing:– Integer32’Base’Range
– ((I >= 0) and (I / 10) mod 10) = 9) -> (I >= 90)
Copyright © 2001 Praxis Critical Systems Limited
Verification activities(1)
• SRS - review plus Z proof• Consistency of global variables and constants, existence
of initial state, derivation of preconditions, safety properties: (CADiZ and “formal partial proof”)
• Traceability
• SDS - review, more Z proof, traceability.
Copyright © 2001 Praxis Critical Systems Limited
Verification activities(2)
• Code
– Development team:
• SPARK Static analysis. Worst-case timing, stack use, and I/O. Informal tests. Program proof.
– IV&V Team:
• Module and Integration Tests based on Z specifications and requirements. 100% statement and MCDC coverage. (AdaTest plus custom tools)
Copyright © 2001 Praxis Critical Systems Limited
Verification activities(3)
• IV&V Team (cont…)• System Validation Tests based on requirements.
• Acceptance test.
• Endurance test.
• Performance test.
• Review of everything…including code refinement, proof obligations, proof scripts, proof rules, documents...
Copyright © 2001 Praxis Critical Systems Limited
Traceability
• Every requirement, SRS paragraph, SDS paragraph, Z schema, SPARK fragment etc. is identified using a consistent naming scheme.
• “Trace-units” map between levels.
• Automated tools check completeness and coverage.
Copyright © 2001 Praxis Critical Systems Limited
Static analysis
• Timing - via comments giving WCET in terms of statements executed and unit calls.
• PERL Script collects and evaluates.
• Execution time of “1 statement” obtained by experiment + safety margin.
• Actually quite useful! Not as good as a “real” WCET tool, but the best we could do.
Copyright © 2001 Praxis Critical Systems Limited
Static analysis(2)
• Display output• Output to display is via a 38400 baud serial line. Limited
bandwidth.
• A problem either display not being updated rapidly enough, or buffer overflow.
• Again, expressions are given in comments giving the worst-case number of characters that can be queued by every procedure. PERL script evaluates.
• Some units very carefully programmed to minimize output.
Copyright © 2001 Praxis Critical Systems Limited
Static analysis(3)
• Stack usage– SPARK is non-recursive.
– Careful coding to avoid large temporary objects and heap allocation.
– Static analysis of generated code yields call tree and worst-case stack usage.
Copyright © 2001 Praxis Critical Systems Limited
Project status: January 2001
• System has passed all System Validation, Endurance, and Performance Tests.
• Acceptance Test with customer completed with no problems.
• Sea trial during Autumn 1998.
• Some cosmetic changes requested, but no reported faults, crashes, or unexpected behaviour.
Copyright © 2001 Praxis Critical Systems Limited
Some metrics
• Faults• Any deliverable, once handed to IV&V, goes under
“change control” - no change unless under a formal fault-report or change-request.
• All fault reports classified - who found it, what project phase, what impact etc. etc.
• Faults range from simple clerical errors to observable system failures.
Copyright © 2001 Praxis Critical Systems Limited
Fault metrics
Project Phase Faults Found (%) Effort (%)
Specification 3 5
Z Proof 12 3
Design, Code & Informal Test 28 19
Unit & Integration Test 21 26
System Validation Tests 32 9.5
Acceptance Test 0 1.5
Code Proof 4 4
Copyright © 2001 Praxis Critical Systems Limited
SHOLIS - Faults found vs. Effort
0
10
20
30
40
50
60
70
80
90
100
Sp
ecif
icat
ion
Z P
roo
f
Hig
h-l
evel
Des
ign
Co
de
Un
it T
est
Inte
gra
tio
n T
est
Co
de
Pro
of
Sy
stem
Val
idat
ion
Acc
epta
nce
Oth
er
No
. o
f F
au
lts
Fo
un
d
0
0.1
0.2
0.3
0.4
0.5
0.6
Eff
icie
ncy