98
CV2.0 Table of contents Introduction Testlist Concepts Introduction 26/07/2015 CoordinationView 2.0 / Import Revit 2016, IFC Version 16.2.0 IFC for Revit 2016 Revit 2016 ships with IFC support. Users can download upgraded versions of the latest version of IFC from either the Autodesk Exchange Apps store or from SourceForge. In addition, the source code for IFC can also be downloaded from SourceForge. The certified version for Autodesk Revit 2016 is v16.2.0, which covers the Link IFC functionality. The version from the app store contains access to help documentation; additional help can be found at the Autodesk and SourceForge Wikis. Although there is currently no automatic update of the IFC add-on, all users that download the applications from the Autodesk Exchange Apps store will receive an update email with links to the current version. SourceForge wiki: https://sourceforge.net/p/ifcexporter/home/Home/ Autodesk Revit Architecture / LT / MEP / Structural

CoordinationView 2.0 / Import Autodesk Revit CV2.0

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Table of contents

Introduction

Testlist

Concepts

Introduction

26/07/2015

CoordinationView 2.0 / Import

Revit 2016, IFC Version 16.2.0

IFC for Revit 2016

Revit 2016 ships with IFC support. Users can download upgraded versions of the latest version of IFC from either the Autodesk Exchange Apps store or from SourceForge.In addition, the source code for IFC can also be downloaded from SourceForge. The certified version for Autodesk Revit 2016 is v16.2.0, which covers the Link IFCfunctionality. The version from the app store contains access to help documentation; additional help can be found at the Autodesk and SourceForge Wikis. Although there iscurrently no automatic update of the IFC add-on, all users that download the applications from the Autodesk Exchange Apps store will receive an update email with links to thecurrent version.

SourceForge wiki: https://sourceforge.net/p/ifcexporter/home/Home/

Autodesk Revit

Architecture / LT / MEP / Structural

Page 2: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Testlist

Name test

manually checkedconcepts total

Beam_01 / 2x3 9 110

Beam_03 / 2x3 4 26

CharsetTest-01A / 2x3 22

Column 01 / 2x3 10 111

CoveringFurnishing-01 / 2x3 51 4 257

CurtainWall-01 / 2x3 23 1 529

Door 01 / 2x3 18 2 222

DuplexHouse_Electrical / 2x3 59 5 165

DuplexHouse_Heating / 2x3 5656

DuplexHouse_Sanitary / 2x3 47 4 152

DuplexHouse_Ventilation / 2x3 39 4 144

Grid 01 / 2x3 7 1 311

Member 01A / 2x3 9 110

Member_01S / 2x3 7 1 210

Pile 01 / 2x3 17 1 119

PlateFastener-01 / 2x3 59 2 667

RampRailing-01 / 2x3 24 2 228

RampSlab-01 / 2x3 16 1 118

RandomArch-X1 Allplan2013 / 2x3 11 3 216

RandomArch-X3 RAC / 2x3 8 19

RandomArch-X4 VW / 2x3 48 10 866

RandomMEP-X2 BENCH / 2x3 2121

RandomMEP-X3 RME / 2x3 1 34

RandomStruc-X2 Scia / 2x3 8 1 110

RandomStruc-X2 TS / 2x3 99

Reinforcement-01 / 2x3 73 10 1194

2Supported Not SupportedRestricted

Page 3: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Name test

manually checkedconcepts total

ReplacementTest_forPile-01 Scia / 2x3 5 27

Roof 01 / 2x3 12 1 215

Site 01 / 2x3 9 1 414

Slab 01A / 2x3 99

Slab 01S / 2x3 1111

Slab 02A / 2x3 19 3 224

Space 01A / 2x3 11 112

StairSlab-01 / 2x3 16 1 219

UnitTest-01A / 2x3 33

Wall 01 / 2x3 16 319

WallStandardCase 01A / 2x3 13 1 115

WallStandardCase 02A / 2x3 9 1 111

WallStandardCase 02S / 2x3 8 1 211

WallStandardCase 03A / 2x3 7 1 19

Window 01 / 2x3 16 2 422

3Supported Not SupportedRestricted

Page 4: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Concepts

Beam_01 / 2x3

103 IfcBeam company statement Beam_01 / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-1 Property Set IFC Common

General company statement Beam_01 / 2x3

4Supported Not SupportedRestricted

Page 5: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

_G4 Remarks

5Supported Not SupportedRestricted

Page 6: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Beam_03 / 2x3

103 IfcBeam company statement Beam_03 / 2x3

030 Geometry

030-1 Geometry Box Revit does not currently import bounding box geometry if the bodyrepresentation contains geometry.

030-2 Geometry Axis At the time of this test, Revit didn't create a beam axis on linking the IFC file.

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

300 Type

300-5 Type Property Set

General company statement Beam_03 / 2x3

_G4 Remarks

6Supported Not SupportedRestricted

Page 7: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

CharsetTest-01A / 2x3

General company statement CharsetTest-01A / 2x3

_G1 Character sets

_G4 Remarks

7Supported Not SupportedRestricted

Page 8: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Column 01 / 2x3

104 IfcColumn company statement Column 01 / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-1 Property Set IFC Common

General company statement Column 01 / 2x3

_G4 Remarks

8Supported Not SupportedRestricted

Page 9: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

CoveringFurnishing-01 / 2x3

210 IfcFlowTerminal company statement CoveringFurnishing-01 / 2x3

001 GUIDs

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

210 Property Set

210-1 Property Set IFC Common

210-6 Property Set IFC any

210-9 Property Set User Defined

9Supported Not SupportedRestricted

Page 10: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

303 IfcCovering company statement CoveringFurnishing-01 / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

070 Voiding

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

200-3 Material Layer Set

210 Property Set

210-1 Property Set IFC Common

10Supported Not SupportedRestricted

Page 11: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

304 IfcFurnishingElement company statement CoveringFurnishing-01 / 2x3

001 GUIDs

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

200-5 Material List

210 Property Set

210-6 Property Set IFC any

210-9 Property Set User Defined

11Supported Not SupportedRestricted

Page 12: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

505 IfcSpace company statement CoveringFurnishing-01 / 2x3

030 Geometry

030-3 Geometry FootPrint

030-6 Geometry Body

030-6-1 Geometry SweptSolid

120 Spatial ContainmentRevit Link IFC supports containment information for levels, but not the buildingand site.

130 Grouping

130-3 Grouping to Zones

230 Classification As of the time of this test, Revit Link IFC does not support importingclassification information.

508 IfcZone company statement CoveringFurnishing-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

130 Grouping

130-5 Is Group

210 Property Set

210-1 Property Set IFC Common

210-9 Property Set User Defined

12Supported Not SupportedRestricted

Page 13: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

General company statement CoveringFurnishing-01 / 2x3

_G4 Remarks

13Supported Not SupportedRestricted

Page 14: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

CurtainWall-01 / 2x3

109 IfcCurtainWall company statement CurtainWall-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-1 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-9 Geometry By Components

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

100 Element Aggregation

100-2 Element Decomposition

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

200-5 Material List Note that Revit tracks the materials of the curtain wall components, but not at thelevel of the entire curtain wall group.

14Supported Not SupportedRestricted

Page 15: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

210 Property Set

210-1 Property Set IFC Common

210-3 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

501 IfcProject company statement CurtainWall-01 / 2x3

010 Naming

502 IfcSite company statement CurtainWall-01 / 2x3

010 Naming

060 Location

060-1 Geographic Location Revit does not import the geographic location for this file.

060-2 Address At the time of this test, Revit didn't import the building address.

503 IfcBuilding company statement CurtainWall-01 / 2x3

010 Naming

020 Placement

020-2 Placement Relative Revit does not have the concept of a building element, so this concept is notsupported.

504 IfcBuildingStorey company statement CurtainWall-01 / 2x3

010 Naming

020 Placement

020-2 Placement Relative

060 Location

060-4 Storey Elevation

15Supported Not SupportedRestricted

Page 16: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

210 Property Set

210-1 Property Set IFC Common

General company statement CurtainWall-01 / 2x3

_G4 Remarks

16Supported Not SupportedRestricted

Page 17: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Door 01 / 2x3

302 IfcDoor company statement Door 01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-5 Geometry Profile Revit Link IFC does not currently support the profile shape representation.

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

080 Filling

080-2 Is Filling Revit maintains a door's host element in the IfcContainedInHost parameter, butthe opening element does not have this parameter.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

17Supported Not SupportedRestricted

Page 18: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

200 Material

200-1 Single Material

200-5 Material List

210 Property Set

210-1 Property Set IFC Common

210-2 Property Set IFC any

210-3 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

300-6 Type Predefined Properties

300-6-1 Type Predefined PropertiesDoor

General company statement Door 01 / 2x3

_G4 Remarks

18Supported Not SupportedRestricted

Page 19: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

DuplexHouse_Electrical / 2x3

204 IfcEnergyConversionDevice company statement DuplexHouse_Electrical / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-2 Type Naming

205 IfcFlowController company statement DuplexHouse_Electrical / 2x3

19Supported Not SupportedRestricted

Page 20: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-2 Type Naming

206 IfcFlowFitting company statement DuplexHouse_Electrical / 2x3

010 Naming

020 Placement

020-2 Placement Relative

20Supported Not SupportedRestricted

Page 21: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-2 Type Naming

208 IfcFlowSegment company statement DuplexHouse_Electrical / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

21Supported Not SupportedRestricted

Page 22: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-2 Type Naming

210 IfcFlowTerminal company statement DuplexHouse_Electrical / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

22Supported Not SupportedRestricted

Page 23: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

210 Property Set

210-1 Property Set IFC Common

210-6 Property Set IFC any

210-9 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

501 IfcProject company statement DuplexHouse_Electrical / 2x3

010 Naming

503 IfcBuilding company statement DuplexHouse_Electrical / 2x3

010 Naming Revit does not have the concept of Building, so this is not supported.

504 IfcBuildingStorey company statement DuplexHouse_Electrical / 2x3

010 Naming

020 Placement

020-2 Placement Relative

150 Spatial Aggregation

150-1 Spatial Composition Revit does not have the concept of Building, so this is not supported.

23Supported Not SupportedRestricted

Page 24: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

507 IfcSystem company statement DuplexHouse_Electrical / 2x3

010 Naming

130 Grouping

130-2 Grouping to Systems

130-5 Is Group

General company statement DuplexHouse_Electrical / 2x3

_G4 Remarks

24Supported Not SupportedRestricted

Page 25: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

DuplexHouse_Heating / 2x3

204 IfcEnergyConversionDevice company statement DuplexHouse_Heating / 2x3

010 Naming

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-5 Type Property Set

205 IfcFlowController company statement DuplexHouse_Heating / 2x3

010 Naming

25Supported Not SupportedRestricted

Page 26: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-5 Type Property Set

206 IfcFlowFitting company statement DuplexHouse_Heating / 2x3

010 Naming

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

26Supported Not SupportedRestricted

Page 27: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

110 Connectivity

110-5 Connectivity by Ports

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-5 Type Property Set

207 IfcFlowMovingDevice company statement DuplexHouse_Heating / 2x3

010 Naming

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-5 Type Property Set

208 IfcFlowSegment company statement DuplexHouse_Heating / 2x3

27Supported Not SupportedRestricted

Page 28: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

010 Naming

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-5 Type Property Set

210 IfcFlowTerminal company statement DuplexHouse_Heating / 2x3

010 Naming

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

28Supported Not SupportedRestricted

Page 29: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

130 Grouping

130-2 Grouping to Systems

300 Type

300-1 Type Geometry

300-5 Type Property Set

General company statement DuplexHouse_Heating / 2x3

_G4 Remarks

29Supported Not SupportedRestricted

Page 30: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

DuplexHouse_Sanitary / 2x3

205 IfcFlowController company statement DuplexHouse_Sanitary / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

30Supported Not SupportedRestricted

Page 31: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

206 IfcFlowFitting company statement DuplexHouse_Sanitary / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

208 IfcFlowSegment company statement DuplexHouse_Sanitary / 2x3

010 Naming

020 Placement

020-2 Placement Relative

31Supported Not SupportedRestricted

Page 32: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

210 IfcFlowTerminal company statement DuplexHouse_Sanitary / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

32Supported Not SupportedRestricted

Page 33: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

200 Material

200-1 Single Material

210 Property Set

210-6 Property Set IFC any

210-9 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

507 IfcSystem company statement DuplexHouse_Sanitary / 2x3

010 Naming

130 Grouping

130-5 Is Group

33Supported Not SupportedRestricted

Page 34: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

250 System Assignment

250-2 Services Spatial Element Revit does not currently assign a system to a spatial element, rather theindividual elements are assigned.

General company statement DuplexHouse_Sanitary / 2x3

_G4 Remarks

34Supported Not SupportedRestricted

Page 35: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

DuplexHouse_Ventilation / 2x3

206 IfcFlowFitting company statement DuplexHouse_Ventilation / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

207 IfcFlowMovingDevice company statement DuplexHouse_Ventilation / 2x3

35Supported Not SupportedRestricted

Page 36: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

208 IfcFlowSegment company statement DuplexHouse_Ventilation / 2x3

010 Naming

020 Placement

020-2 Placement Relative

36Supported Not SupportedRestricted

Page 37: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

210 IfcFlowTerminal company statement DuplexHouse_Ventilation / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

37Supported Not SupportedRestricted

Page 38: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

040 Presentation

040-1 Geometric Presentation

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-2 Grouping to Systems

507 IfcSystem company statement DuplexHouse_Ventilation / 2x3

010 Naming

130 Grouping

130-5 Is Group

250 System Assignment

250-2 Services Spatial Element Revit does not currently assign a system to a spatial element, rather theindividual elements are assigned.

General company statement DuplexHouse_Ventilation / 2x3

_G4 Remarks

38Supported Not SupportedRestricted

Page 39: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Grid 01 / 2x3

509 IfcGrid company statement Grid 01 / 2x3

001 GUIDs

002 History Revit does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-3 Geometry FootPrint

040 Presentation

040-1 Geometric Presentation Revit does not import color information for grids.

050 CAD Layer At the time of this test, Revit did not import CAD layer information for grids.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

210 Property Set

210-3 Property Set User Defined

270 Grid Usage

270-1 Grid Axes

General company statement Grid 01 / 2x3

_G4 Remarks

39Supported Not SupportedRestricted

Page 40: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Member_01S / 2x3

401 IfcMember company statement Member_01S / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

110 Connectivity

110-1 Connectivity Basic Revit reads the connection information but it is not shown in the imported model.

110-3 Connectivity Realization

110-3-1 Connectivity Realized Revit reads the connection information but it is not shown in the imported model.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

300 Type

300-1 Type Geometry

General company statement Member_01S / 2x3

_G4 Remarks

40Supported Not SupportedRestricted

Page 41: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Member 01A / 2x3

401 IfcMember company statement Member 01A / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

300 Type

300-1 Type Geometry

General company statement Member 01A / 2x3

_G4 Remarks

41Supported Not SupportedRestricted

Page 42: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Pile 01 / 2x3

404 IfcPile company statement Pile 01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-1 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

050 CAD Layer

070 Voiding

070-3 Voiding Geometry SweptSolid

100 Element Aggregation

100-2 Element Decomposition

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

42Supported Not SupportedRestricted

Page 43: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

200 Material

200-1 Single Material

210 Property Set

210-3 Property Set User Defined

300 Type

300-1 Type Geometry

300-3 Type Material

300-5 Type Property Set

General company statement Pile 01 / 2x3

_G4 Remarks

43Supported Not SupportedRestricted

Page 44: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

PlateFastener-01 / 2x3

103 IfcBeam company statement PlateFastener-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-9 Geometry Mapped

104 IfcColumn company statement PlateFastener-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-9 Geometry Mapped

100 Element Aggregation

100-2 Element Decomposition

210 Property Set

210-3 Property Set User Defined

44Supported Not SupportedRestricted

Page 45: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

401 IfcMember company statement PlateFastener-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

210 Property Set

210-1 Property Set IFC Common

210-3 Property Set User Defined

300 Type

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

402 IfcPlate company statement PlateFastener-01 / 2x3

45Supported Not SupportedRestricted

Page 46: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

030-6-5 Geometry Explicit

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

070 Voiding

070-3 Voiding Geometry SweptSolid

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-2 Material Layer Set

210 Property Set

210-1 Property Set IFC Common

210-3 Property Set User Defined

46Supported Not SupportedRestricted

Page 47: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

403 IfcFooting company statement PlateFastener-01 / 2x3

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

405 IfcFastener company statement PlateFastener-01 / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-2 Geometry Axis At the time of this test, Revit didn't create a fastener axis on linking the IFC file.

406 IfcMechanicalFastener company statement PlateFastener-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

47Supported Not SupportedRestricted

Page 48: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-6 Property Set IFC any

210-9 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

General company statement PlateFastener-01 / 2x3

_G4 Remarks

48Supported Not SupportedRestricted

Page 49: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RampRailing-01 / 2x3

107 IfcRamp company statement RampRailing-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-1 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-9 Geometry By Components

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

100 Element Aggregation

100-2 Element Decomposition

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

49Supported Not SupportedRestricted

Page 50: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

210 Property Set

210-1 Property Set IFC Common

210-3 Property Set User Defined

108 IfcRailing company statement RampRailing-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

200-5 Material List

50Supported Not SupportedRestricted

Page 51: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

210 Property Set

210-1 Property Set IFC Common

210-3 Property Set User Defined

General company statement RampRailing-01 / 2x3

_G4 Remarks

51Supported Not SupportedRestricted

Page 52: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RampSlab-01 / 2x3

105 IfcSlab company statement RampSlab-01 / 2x3

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

070 Voiding

070-3 Voiding Geometry SweptSolid

107 IfcRamp company statement RampSlab-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-1 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-9 Geometry By Components

52Supported Not SupportedRestricted

Page 53: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

100 Element Aggregation

100-2 Element Decomposition

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-1 Property Set IFC Common

210-3 Property Set User Defined

General company statement RampSlab-01 / 2x3

_G4 Remarks

53Supported Not SupportedRestricted

Page 54: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RandomArch-X1 Allplan2013 / 2x3

101 IfcWallStandardCase company statement RandomArch-X1 Allplan2013 / 2x3

020 Placement

020-2 Placement Relative

030 Geometry

030-2 Geometry Axis Revit Link IFC does not currently display the wall axis.

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

070 Voiding

070-2 Voiding Geometry Explicit

080 Filling

081 Has Filling

081-1 Has Filling Door Revit maintains a door's host element in the IfcContainedInHost parameter, butthe opening element does not have this parameter.

200 Material

200-4 Material Layer Usage

210 Property Set

210-3 Property Set User Defined

102 IfcWall company statement RandomArch-X1 Allplan2013 / 2x3

020 Placement

020-2 Placement Relative

54Supported Not SupportedRestricted

Page 55: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-2 Geometry Axis Revit Link IFC does not currently display the wall axis.

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

070 Voiding

070-1 Voiding Geometry Explicit

080 Filling

080-1 Has Filling

080-1-1 Has Filling Door Revit maintains a door's host element in the IfcContainedInHost parameter, butthe opening element does not have this parameter.

080-1-2 Has Filling Window Revit maintains a windowss host element in the IfcContainedInHost parameter,but the opening element does not have this parameter.

General company statement RandomArch-X1 Allplan2013 / 2x3

_G4 Remarks

55Supported Not SupportedRestricted

Page 56: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RandomArch-X3 RAC / 2x3

101 IfcWallStandardCase company statement RandomArch-X3 RAC / 2x3

020 Placement

020-2 Placement Relative

102 IfcWall company statement RandomArch-X3 RAC / 2x3

020 Placement

020-2 Placement Relative

105 IfcSlab company statement RandomArch-X3 RAC / 2x3

010 Naming

020 Placement

020-2 Placement Relative

110 IfcRoof company statement RandomArch-X3 RAC / 2x3

010 Naming

020 Placement

020-2 Placement Relative

111 IfcBuildingElementProxy company statement RandomArch-X3 RAC / 2x3

010 Naming

503 IfcBuilding company statement RandomArch-X3 RAC / 2x3

010 Naming Revit does not currently import the building name from IFC.

General company statement RandomArch-X3 RAC / 2x3

_G4 Remarks

56Supported Not SupportedRestricted

Page 57: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RandomArch-X4 VW / 2x3

101 IfcWallStandardCase company statement RandomArch-X4 VW / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

210 Property Set

210-1 Property Set IFC Common

102 IfcWall company statement RandomArch-X4 VW / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

57Supported Not SupportedRestricted

Page 58: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-5 Geometry Explicit

040 Presentation

040-2 Material Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

105 IfcSlab company statement RandomArch-X4 VW / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

040 Presentation

040-2 Material Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

58Supported Not SupportedRestricted

Page 59: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

200 Material

200-1 Single Material

111 IfcBuildingElementProxy company statement RandomArch-X4 VW / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

040 Presentation

040-2 Material Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-3 Property Set User Defined

403 IfcFooting company statement RandomArch-X4 VW / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

59Supported Not SupportedRestricted

Page 60: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

020 Placement

020-1 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

040 Presentation

040-2 Material Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

501 IfcProject company statement RandomArch-X4 VW / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

005 Project Units

005-1 Project Metric Units

010 Naming

150 Spatial Aggregation

150-1 Spatial Composition At the time of this test, Revit had the containment information for levels, but notfor building or site.

150-2 Spatial Decomposition At the time of this test, Revit had the containment information for levels, but notfor building or site.

502 IfcSite company statement RandomArch-X4 VW / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

60Supported Not SupportedRestricted

Page 61: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

010 Naming

020 Placement

020-1 Placement Absolute

030 Geometry

030-1 Geometry Box Revit does not currently import the bounding box if there is a bodyrepresentation.

030-6 Geometry Body

030-6-5 Geometry Explicit

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

060 Location

060-1 Geographic Location

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

150 Spatial Aggregation

150-1 Spatial Composition At the time of this test, Revit had the containment information for levels, but notfor building or site.

150-2 Spatial Decomposition At the time of this test, Revit had the containment information for levels, but notfor building or site.

210 Property Set

210-9 Property Set User Defined

General company statement RandomArch-X4 VW / 2x3

_G4 Remarks

61Supported Not SupportedRestricted

Page 62: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RandomMEP-X2 BENCH / 2x3

206 IfcFlowFitting company statement RandomMEP-X2 BENCH / 2x3

030 Geometry

030-6 Geometry Body

030-6-9 Geometry Mapped

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

207 IfcFlowMovingDevice company statement RandomMEP-X2 BENCH / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

62Supported Not SupportedRestricted

Page 63: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

120 Spatial Containment

200 Material

200-1 Single Material

210 Property Set

210-9 Property Set User Defined

208 IfcFlowSegment company statement RandomMEP-X2 BENCH / 2x3

030 Geometry

030-6 Geometry Body

030-6-9 Geometry Mapped

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

210 IfcFlowTerminal company statement RandomMEP-X2 BENCH / 2x3

030 Geometry

030-6 Geometry Body

030-6-9 Geometry Mapped

100 Element Aggregation

100-4 Port Assignment

110 Connectivity

110-5 Connectivity by Ports

63Supported Not SupportedRestricted

Page 64: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

General company statement RandomMEP-X2 BENCH / 2x3

_G4 Remarks

64Supported Not SupportedRestricted

Page 65: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RandomMEP-X3 RME / 2x3

506 IfcGroup company statement RandomMEP-X3 RME / 2x3

001 GUIDs Revit imports IfcSystem but no other IfcGroup.

010 Naming Revit imports IfcSystem but no other IfcGroup.

130 Grouping

130-5 Is Group Revit imports IfcSystem but no other IfcGroup.

General company statement RandomMEP-X3 RME / 2x3

_G4 Remarks

65Supported Not SupportedRestricted

Page 66: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RandomStruc-X2 Scia / 2x3

411 IfcTendon company statement RandomStruc-X2 Scia / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-4 GeometryAdvancedSweptSolid

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

General company statement RandomStruc-X2 Scia / 2x3

_G4 Remarks

66Supported Not SupportedRestricted

Page 67: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

RandomStruc-X2 TS / 2x3

409 IfcReinforcingBar company statement RandomStruc-X2 TS / 2x3

010 Naming

030 Geometry

030-6 Geometry Body

030-6-4 GeometryAdvancedSweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

100 Element Aggregation

100-1 Element Composition

200 Material

200-1 Single Material

General company statement RandomStruc-X2 TS / 2x3

_G4 Remarks

67Supported Not SupportedRestricted

Page 68: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Reinforcement-01 / 2x3

101 IfcWallStandardCase company statement Reinforcement-01 / 2x3

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

103 IfcBeam company statement Reinforcement-01 / 2x3

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

104 IfcColumn company statement Reinforcement-01 / 2x3

020 Placement

020-2 Placement Relative

68Supported Not SupportedRestricted

Page 69: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

105 IfcSlab company statement Reinforcement-01 / 2x3

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

403 IfcFooting company statement Reinforcement-01 / 2x3

010 Naming

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

210 Property Set

210-3 Property Set User Defined

69Supported Not SupportedRestricted

Page 70: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

407 IfcDiscreteAccessory company statement Reinforcement-01 / 2x3

001 GUIDs

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-9 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

408 IfcElementAssembly company statement Reinforcement-01 / 2x3

001 GUIDs

010 Naming

70Supported Not SupportedRestricted

Page 71: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-9 Geometry By Components

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

100 Element Aggregation

100-2 Element Decomposition

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

210 Property Set

210-9 Property Set User Defined

409 IfcReinforcingBar company statement Reinforcement-01 / 2x3

001 GUIDs

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-4 GeometryAdvancedSweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

71Supported Not SupportedRestricted

Page 72: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-9 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

410 IfcReinforcingMesh company statement Reinforcement-01 / 2x3

001 GUIDs

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-4 GeometryAdvancedSweptSolid

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

72Supported Not SupportedRestricted

Page 73: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-9 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

501 IfcProject company statement Reinforcement-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

005 Project Units

005-1 Project Metric Units

008 Representation Context

008-1 Representation Main Context Revit doesn't display information about the Representation Main Context fromIFC.

008-2 Representation Sub Context

008-2-2 Representation SubContext 3D

Revit doesn't display information about the Representation Sub Context 3D fromIFC.

010 Naming

73Supported Not SupportedRestricted

Page 74: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

150 Spatial Aggregation

150-2 Spatial Decomposition Revit does not currently import the spatial decomposition of IFCProject.

503 IfcBuilding company statement Reinforcement-01 / 2x3

001 GUIDs At the time of this test, Revit didn't import the building GUID.

002 History Revit Link IFC does not import the owner history.

010 Naming Revit doesn't currently import the building name.

020 Placement

020-1 Placement Absolute

060 Location

060-2 Address At the time of this test, Revit didn't import the building address.

150 Spatial Aggregation

150-1 Spatial Composition Revit does not have the concept of Building and so this is not supported.

150-2 Spatial Decomposition Revit does not have the concept of Building and so this is not supported.

504 IfcBuildingStorey company statement Reinforcement-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

060 Location

060-4 Storey Elevation

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

74Supported Not SupportedRestricted

Page 75: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

150 Spatial Aggregation

150-1 Spatial Composition

150-2 Spatial Decomposition

General company statement Reinforcement-01 / 2x3

_G4 Remarks

75Supported Not SupportedRestricted

Page 76: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

ReplacementTest_forPile-01 Scia / 2x3

101 IfcWallStandardCase company statement ReplacementTest_forPile-01 Scia / 2x3

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid This was accidentally marked as restricted at the time of testing; this concept isactually supported for this test.

104 IfcColumn company statement ReplacementTest_forPile-01 Scia / 2x3

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid This was accidentally marked as restricted at the time of testing; this concept isactually supported for this test.

030-6-2 Geometry Clipping

050 CAD Layer

200 Material

200-1 Single Material

210 Property Set

210-3 Property Set User Defined

General company statement ReplacementTest_forPile-01 Scia / 2x3

_G4 Remarks

76Supported Not SupportedRestricted

Page 77: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Roof 01 / 2x3

101 IfcWallStandardCase company statement Roof 01 / 2x3

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

105 IfcSlab company statement Roof 01 / 2x3

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

030-6-9 Geometry Mapped

070 Voiding

070-3 Voiding Geometry SweptSolid

080 Filling

080-1 Has Filling

080-1-2 Has Filling Window At the time of this test, Revit did not import the relation between windows andtheir hosts.

200 Material

200-2 Material Layer Set

110 IfcRoof company statement Roof 01 / 2x3

77Supported Not SupportedRestricted

Page 78: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-1 Geometry Box Revit does not currently import bounding box geometry if there is body geometrypresent.

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

100 Element Aggregation

100-2 Element Decomposition

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

General company statement Roof 01 / 2x3

_G4 Remarks

78Supported Not SupportedRestricted

Page 79: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Site 01 / 2x3

502 IfcSite company statement Site 01 / 2x3

001 GUIDs

002 History Revit does not import the owner history.

010 Naming

020 Placement

020-1 Placement Absolute

030 Geometry

030-1 Geometry Box Revit does not currently import the bounding box geometry for sites.

030-3 Geometry FootPrint Revit does not currently import footprint geometry for sites.

030-6 Geometry Body

030-6-5 Geometry Explicit

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

060 Location

060-1 Geographic Location

060-2 Address At the time of this test, Revit didn't import the building address.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

210 Property Set

210-1 Property Set IFC Common

79Supported Not SupportedRestricted

Page 80: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

General company statement Site 01 / 2x3

_G4 Remarks

80Supported Not SupportedRestricted

Page 81: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Slab 01A / 2x3

105 IfcSlab company statement Slab 01A / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

050 CAD Layer

200 Material

200-2 Material Layer Set

200-3 Material Layer Usage

210 Property Set

210-1 Property Set IFC Common

General company statement Slab 01A / 2x3

_G4 Remarks

81Supported Not SupportedRestricted

Page 82: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Slab 01S / 2x3

105 IfcSlab company statement Slab 01S / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

050 CAD Layer

200 Material

200-2 Material Layer Set

200-3 Material Layer Usage

210 Property Set

210-1 Property Set IFC Common

General company statement Slab 01S / 2x3

_G4 Remarks

82Supported Not SupportedRestricted

Page 83: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Slab 02A / 2x3

105 IfcSlab company statement Slab 02A / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-1 Geometry Box Revit does not currently import bounding box geometry if there is a bodyrepresentation.

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

070 Voiding

070-1 Voiding Geometry Explicit

070-2 Voiding Geometry Mapped

070-3 Voiding Geometry SweptSolid

080 Filling

080-1 Has Filling

080-1-1 Has Filling Door At the time of this test, Revit Link IFC supported the import of door fillingopenings in slabs, but did not maintain the relation between slab and door

080-1-2 Has Filling Window At the time of this test, Revit Link IFC supported the import of window fillingopenings in slabs, but did not maintain the relation between slab and window

83Supported Not SupportedRestricted

Page 84: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

130 Grouping

130-1 Grouping General At the time of this test, Revit didn't group elements on linking the IFC file.

200 Material

200-1 Single Material

200-2 Material Layer Set

210 Property Set

210-1 Property Set IFC Common

210-2 Property Set IFC any

210-3 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

General company statement Slab 02A / 2x3

_G4 Remarks

84Supported Not SupportedRestricted

Page 85: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Space 01A / 2x3

505 IfcSpace company statement Space 01A / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

150 Spatial Aggregation

150-1 Spatial Composition

210 Property Set

210-1 Property Set IFC Common

210-6 Property Set IFC any

General company statement Space 01A / 2x3

85Supported Not SupportedRestricted

Page 86: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

_G4 Remarks

86Supported Not SupportedRestricted

Page 87: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

StairSlab-01 / 2x3

105 IfcSlab company statement StairSlab-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

070 Voiding

070-3 Voiding Geometry SweptSolid

106 IfcStair company statement StairSlab-01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-1 Placement Relative

87Supported Not SupportedRestricted

Page 88: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

030 Geometry

030-6 Geometry Body

030-6-5 Geometry Explicit

030-9 Geometry By Components

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

100 Element Aggregation

100-2 Element Decomposition

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-1 Single Material

210 Property Set

210-1 Property Set IFC Common

General company statement StairSlab-01 / 2x3

_G4 Remarks

88Supported Not SupportedRestricted

Page 89: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

UnitTest-01A / 2x3

501 IfcProject company statement UnitTest-01A / 2x3

005 Project Units

005-1 Project Metric Units

005-2 Project Imperial Units

General company statement UnitTest-01A / 2x3

_G4 Remarks

89Supported Not SupportedRestricted

Page 90: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Wall 01 / 2x3

102 IfcWall company statement Wall 01 / 2x3

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

030-6-5 Geometry Explicit

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

070 Voiding

070-1 Voiding Geometry Explicit

070-3 Voiding Geometry SweptSolid

080 Filling

080-1 Has Filling

080-1-1 Has Filling Door At the time of this test, Revit did not display the relation between doors and theirhosts.

080-1-2 Has Filling Window At the time of this test, Revit did not display the relation between doors and theirhosts.

90Supported Not SupportedRestricted

Page 91: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

200 Material

200-1 Single Material

210 Property Set

210-1 Property Set IFC Common

300 Type

300-3 Type Material

300-5 Type Property Set

301 IfcWindow company statement Wall 01 / 2x3

020 Placement

020-2 Placement Relative

302 IfcDoor company statement Wall 01 / 2x3

020 Placement

020-2 Placement Relative

General company statement Wall 01 / 2x3

_G4 Remarks

91Supported Not SupportedRestricted

Page 92: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

WallStandardCase 01A / 2x3

101 IfcWallStandardCase company statement WallStandardCase 01A / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-2 Geometry Axis

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

040 Presentation

040-1 Geometric Presentation

040-2 Material Presentation

050 CAD Layer

110 Connectivity

110-2 Connectivity Path Revit Link IFC does not currently maintain the connectivity path information forwalls.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-4 Material Layer Usage

210 Property Set

210-3 Property Set User Defined

92Supported Not SupportedRestricted

Page 93: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

300 Type

300-3 Type Material

300-5 Type Property Set

General company statement WallStandardCase 01A / 2x3

_G4 Remarks

93Supported Not SupportedRestricted

Page 94: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

WallStandardCase 02A / 2x3

101 IfcWallStandardCase company statement WallStandardCase 02A / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-2 Geometry Axis

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

050 CAD Layer

110 Connectivity

110-2 Connectivity Path Revit Link IFC does not currently maintain the connectivity path information forwalls.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-4 Material Layer Usage

210 Property Set

210-1 Property Set IFC Common

General company statement WallStandardCase 02A / 2x3

_G4 Remarks

94Supported Not SupportedRestricted

Page 95: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

WallStandardCase 02S / 2x3

101 IfcWallStandardCase company statement WallStandardCase 02S / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-2 Geometry Axis Revit Link IFC does not currently display the axis representation for walls.

030-6 Geometry Body

030-6-1 Geometry SweptSolid

030-6-2 Geometry Clipping

050 CAD Layer

110 Connectivity

110-2 Connectivity Path Revit Link IFC does not currently maintain the connectivity path information forwalls.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

200 Material

200-4 Material Layer Usage

210 Property Set

210-1 Property Set IFC Common

General company statement WallStandardCase 02S / 2x3

_G4 Remarks

95Supported Not SupportedRestricted

Page 96: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

WallStandardCase 03A / 2x3

101 IfcWallStandardCase company statement WallStandardCase 03A / 2x3

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-2 Geometry Axis At the time of this test, Revit didn't create a wall axis on linking the IFC file.

030-6 Geometry Body

030-6-1 Geometry SweptSolid

070 Voiding

070-1 Voiding Geometry SweptSolid

070-2 Voiding Geometry Explicit

070-3 Voiding Geometry Mapped

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

General company statement WallStandardCase 03A / 2x3

_G4 Remarks

96Supported Not SupportedRestricted

Page 97: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

Window 01 / 2x3

301 IfcWindow company statement Window 01 / 2x3

001 GUIDs

002 History Revit Link IFC does not import the owner history.

010 Naming

020 Placement

020-2 Placement Relative

030 Geometry

030-5 Geometry Profile Revit Link IFC does not currently support the profile shape representation.

030-6 Geometry Body

030-6-5 Geometry Explicit

030-6-9 Geometry Mapped

040 Presentation

040-1 Geometric Presentation

050 CAD Layer

080 Filling

080-2 Is Filling Revit maintains a window's host element in the IfcContainedInHost parameter,but the opening element does not have this parameter.

120 Spatial Containment At the time of this test, Revit had the containment information for levels, but notfor building or site.

97Supported Not SupportedRestricted

Page 98: CoordinationView 2.0 / Import Autodesk Revit CV2.0

CV2.0

Autodesk Revit Architecture

200 Material

200-1 Single Material

200-5 Material List

210 Property Set

210-1 Property Set IFC Common

210-2 Property Set IFC any

210-3 Property Set User Defined

300 Type

300-1 Type Geometry

300-2 Type Naming

300-3 Type Material

300-5 Type Property Set

300-6 Type Predefined Properties

300-6-1 Type Predefined PropertiesWindow

At the time of this test, Revit did not import the Type properties of windows suchas Operation and Construction Type.

General company statement Window 01 / 2x3

_G4 Remarks

98Supported Not SupportedRestricted