7/26/2019 Converter 8305-1 UK
1/4Page 1Design and specifications subject to change without notice
Data Sheet 8305-1www.baumerprocess.com
Description
The 4...20 mA loop current is measured and converted into 0...20 mA
or 0...10 V, respectively, depending on the type of converter.
The conversion is based on internal voltage and resistance references.
The signal converter can be used to convert a 4...20 mA signal into a
0...20 mA current signal or a 0...10 V voltage signal.
To minimize a possible voltage drop the converter must be located as
close to the voltage receiver as possible, whereas for current signals
large lengths of cables may be used.
Signal Converter I/I or I/U
Input: 4...20 mA
Output: 0...20 mA or 0...10 VLoop powered
Protected against incorrect connection
Accuracy better than 0.25% f.r.
7/26/2019 Converter 8305-1 UK
2/4Page 2Design and specifications subject to change without notice
Data Sheet 8305-1www.baumerprocess.com
Technical Data
Ordering Details - Signal Converter I/I or I/U
82 42 - 31x
Data Common for both Types
Input data
Protection +/- 24 Vdc
Current limiting 100 mA
Output dataAccuracy < 0.25% f.r.
Temperature drift Typ. 0.005% f.r. per C
Max. 0.01% f.r. per C
Environmental conditions
Operating temperature -10...60C
Storage temperature -35...85C
Humidity < 90% RH, non-condensing
Vibrations Lloyds Register, test 1
EMC data
Immunity EN 50082-2Emission EN 50081-1
Mechanical data
Dimensions 62 x 88 x 24 mm
DIN-rail mounting DIN 46277
Protection class Housing: IP 30
Terminals: IP 10
Weight 0.1 kg
Disposal of product and packing
According to national laws or by returning to Baumer
Input Output 7 digit
4...20 mA 0...20 mA
4...20 mA 0...10 V
Signal Converter I/I
Input data
Signal type 4...20 mA, 2-wire
Voltage drop 5.5 V (excl. voltage drop across the
output)
Output data
Signal type 0...20 mA, 2-wire
Load < 400 Ohm
Signal Converter I/U
Input data
Input signal 4...20 mA, 2-wire
Voltage drop < 14 V
Output data
Output impedance Nom. 2 Ohm
Output signal 0.03...10 V
Load > 600 Ohm
1
2
4
3
+
Signal Converter I/I Signal Converter I/U
4...20 mA
0...20 mA
4...20 mA
0...10 V
4
3
1
2
+ +
+
4
5
Block Diagram
7/26/2019 Converter 8305-1 UK
3/4Page 3Design and specifications subject to change without notice
Data Sheet 8305-1www.baumerprocess.com
230 Vac 0...20 mA
4...20 mA
+ - + - + -
Power supply FlexTemp Iso Signal converter Indicator instrument
RTD
3 4 3 4 3 4
1 2 1 2 1 2
Example of Application
[mm]
88
6265.5
24
Dimensional Drawings
C
7/26/2019 Converter 8305-1 UK
4/4Page 4Design and specifications subject to change without notice
Data Sheet 8305-1www.baumerprocess.com
UK/2007-03-21
Thisdat
asheetmayonlybereproducedinfull.