37
31 . 01 Han Hoods Housings Contents Hoods/Housings with metric thread Page Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.02 Han ® Hoods and Housings with metric thread . . . . . . . . . . . . . . . . . . . . . . . 31.03 Standard Hoods/Housings size Han A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.10 Standard Hoods/Housings size Han B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.16 – with 2 levers on the housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.18 – with 1 lever on the housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.20 – with 2 levers on the hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.22 – with central locking lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.23 – for 2 inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.24 Han ® M Hoods/Housings for harsh environmental requirements . . . . . . . . . 31.26 Han ® HPR Hoods/Housings pressure tight and EMI resistant . . . . . . . . . . . 31.32 Han ® EMC Hoods/Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.35 Han ® EMC/B Hoods/Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.37 Hoods/Housings for special applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.39 Note: Han ® hoods and housing with NPT-thread also available by HARTING Inc.of North America, USA Enclosure type acc. UL 50: NEMA 4/12 (File E235076)

Contents Hoods/Housings with metric thread Page - ProSoft · Hoods/Housings with metric thread Page ... Hoods/Housings seal NBR Limiting temperatures - 40 OC / +125 OC Enclosure type

Embed Size (px)

Citation preview

31.01

Han HoodsHousings

Contents

Hoods/Housings with metric thread Page

Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.02

Han® Hoods and Housings with metric thread . . . . . . . . . . . . . . . . . . . . . . . 31.03

Standard Hoods/Housings size Han A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.10

Standard Hoods/Housings size Han B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.16

– with 2 levers on the housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.18

– with 1 lever on the housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.20

– with 2 levers on the hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.22

– with central locking lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.23

– for 2 inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.24

Han® M Hoods/Housings for harsh environmental requirements . . . . . . . . . 31.26

Han® HPR Hoods/Housings pressure tight and EMI resistant . . . . . . . . . . . 31.32

Han® EMC Hoods/Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.35

Han® EMC/B Hoods/Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.37

Hoods/Housings for special applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.39

Note: Han® hoods and housing with NPT-thread also available by HARTING Inc. of North America, USA

Enclosure type acc. UL 50: NEMA 4/12(File E235076)

31.02

Han HoodsHousings

Technical characteristics

Han® 3 A Hoods/Housings thermoplasticMaterial Polycarbonate RAL 7032Locking element Polyamide RAL 7032Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Flammability acc. to UL 94 V 0Degree of protection acc. to DIN EN 60 529for coupled connector IP 67

Han® 3 A Hoods/Housings metalMaterial Die cast zinc alloySurface powder-coated

RAL 7037 (grau)Locking element Steel, zinc platedHoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 44

IP 67 is achieved with sealscrew 09 20 000 9918

Han® M Hoods/Housings for harsh environmental requirementsMaterial Die cast aluminium alloySurface- Priming Chromated- Top Coat Epoxy powder paint (black)Locking element V2A SteelHoods/Housings seal FPMLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65Size Han® 3 A IP 44

IP 67 is achieved with seal screw09 20 000 9918

Han® Standard Hoods/HousingsMaterial Die cast aluminium alloySurface powder-coated RAL 7037 (grey)Locking element V2A Steel / Steel, zinc plated /

Han-Easy Lock®

Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65

Han® HPR Hoods/Housings pressure tightand highly EMI resistant

Material corrosion resistant die cast aluminium alloy

Surface- Top Coat Epoxy powder paint (black)Locking element- Screw locking M 6

- Material V2A Steel- Tightening torque 4 Nm

- Toggle locking- Material V2A Steel

Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 68

Han® EMC Hoods/Housings for high shieldingMaterial Die cast aluminium alloySurface conductive finishLocking element V2A Steel / Steel, zinc platedHoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65Size Han® 3 A IP 44

IP 67 is achieved with seal screw09 20 000 9918

Han® EMC/ B Hoods/Housings for high shieldingMaterial- hoods/housings Die cast aluminium alloy- shielded frames Die cast zinc alloySurface- hoods/housings electrical conductive- shielded frames electrical conductiveLocking element Han-Easy Lock®

Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65

31.03

M 20M 25M 32M 40M 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm

M 40M 40

M 32M 32

M 25M 25

M 20M 20

M 20

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm

Pg 11Pg 13.5Pg 16Pg 21Pg 29Pg 36Pg 42

Pg

PG 29PG 29

PG 29

PG 21PG 21

PG 16PG 16

PG 13.5

PG 11PG 11

Han HoodsHousings

Han® Hoods and Housings with Metric Cable Entries

The Cross Reference table showsthe correlation between the PGversions and the new metric types.

Please notice that the maximumcable diameter will be reduced by thenew metric cable glands.

Below is shown the cable range of metric glands:

The reason for the new product offerings is the publication of the international DIN EN 50262 metric threadspecification.

The existing PG series, PG 7 to PG 48 will be, in time, replaced by the metric series M 12 to M 63.

The adoption of metric threads considerably simplifies the understanding and specification of glands as theproduct type description contains the thread dimension. E.g. M 20 refers to 20 mm thread diameter.

To differentiate the metric threaded hoods and housings from the previous PG versions metric types will be marked with M .

CrCross Refoss ReferenceerenceMetric

31.10

A B

C

A 09 20 003 54071)3)1)

09 20 003 54082)3)4)

B 09 20 003 54452)1)1)

09 20 003 54461)1)1)

09 20 003 54472)3)4)

C 09 20 003 54481)1)1)

09 20 003 54492)4)1)

Hoods/Housings thermoplastic Size 3 A

Identification Part No. M Drawing Dimensions in mm

Hoo

ds

Hoodsside-entry grey

19 20 003 0620 20

black19 20 003 0627 20

Protection coversfor hoods

09 20 003 54421)

09 20 003 54412)

grey19 20 003 0420 20

black19 20 003 0427 20

Hoodstop-entry

Stock items in bold type1) for mounted male insert2) for mounted female insert

3) for metal housings and cable to cable hoods also4) for mounted Han-Brid® male and female insert

Han HoodsHousings

Hou

sing

s

Housings bulkhead mounting

grey09 20 003 0320 –

black09 20 003 0327 –

grey09 20 003 0820 –

black09 20 003 0827 –

Housingssurface mounting1 side-entry grey

19 20 003 0220 20

black19 20 003 0227 20

Hoods cable to cable

grey19 20 003 0720 20

black19 20 003 0727 20

Panel cut out 22 x 22 mm

Panel cut out 22 x 22 mm

for housings

for hoods cable to cable

Protection covers

31.11

09 20 003 0801

09 20 003 0301

19 20 003 1250 20

19 20 003 1252 20

19 20 003 1150 20

19 20 003 1750 20

09 20 003 54221)

09 20 003 54212)

09 20 003 54261)

09 20 003 54252)

09 20 003 54281)

09 20 003 54272)

09 20 003 03051)

09 20 003 03062)

19 20 003 1640 20

19 20 003 1440 20

Han HoodsHousings

Hoods/Housings with metric thread Size 3 A

Metal

Identification Part No. M Drawing Dimensions in mm

1) for mounted male insert 2) for mounted female insert Stock items in bold type

Hoo

dsH

ousi

ngs

Panel cut out22 x 22 mm

Panel cut out22 x 22 mm

Housingsbulkhead mounting

Housingsurface mounting

1 side-entry

bottom closed

Housingscrew mounting

Hood cable to cable

Protection coversfor hoods

Protection coversfor housings

for hoods cable to cable

with fixed cover

without sealing

with sealing

Hoodside-entry

Hoodtop-entry

31.12

Han HoodsHousings

Hoodsside-entry

19 20 010 1540 20

19 20 010 0546 25

Hoodstop-entry

19 20 010 1440 20

19 20 010 0446 25

Protection coversfor hoods

09 20 010 5423

Protection coversfor housings

09 20 010 5425

Hoo

ds

Housingsbulkhead mounting

09 20 010 0301 –

with thermo-plastic cover

09 20 010 0321 –

Housingssurface mounting

1 side-entry 19 20 010 02511) 1 x 25

2 side- 19 20 010 0290 2 x 20entries

with thermo-plastic cover

19 20 010 0295 2 x 20

Hou

sing

sStandard Hoods/Housings with metric thread Size 10 A

with 1 lever on the housing

Part No.

Identification Low construction High construction M Drawing Dimensions in mm

1) only metal glands Stock items in bold type

31.13

Han HoodsHousings

Hoodsside-entry

19 20 016 1540 20

19 20 016 0546 25

Hoodstop-entry

19 20 016 1440 20

19 20 016 0446 25

Hoo

ds

Housingsbulkhead mounting

09 20 016 0301 –

with thermo-plastic cover

09 20 016 0321 –

Housingssurface mounting

1 side-entry 19 20 016 02511) 1 x 25

2 side- 19 20 016 0290 2 x 20entries 19 20 016 0291 2 x 25

with thermo-plastic cover

19 20 016 0295 2 x 20

Hou

sing

sStandard Hoods/Housings with metric thread Size 16 A

with 1 lever on the housing

Part No.

Identification Low construction High construction M Drawing Dimensions in mm

1) only metal glands Stock items in bold type

Protection coversfor hoods

09 20 016 5423

Protection coversfor housings

09 20 016 5425

31.14

Han HoodsHousings

Hoodsside-entry

19 20 032 1521 25

19 20 032 0527 32

Hoodstop-entry

19 20 032 0426 2519 20 032 0427 32

Protection cover

09 20 032 5401 –

Protection cover

09 20 032 5405

Hoo

ds

Housingbulkhead mounting

09 20 032 0301 –

Housingssurface mounting

1 side-entry 19 20 032 0231 1 x 25

19 20 032 0232 1 x 32

2 side- 19 20 032 0272 2 x 32entries

Hou

sing

sStandard Hoods/Housings with metric thread Size 32 A

with 2 levers on the housing for 2 inserts

Part No.

Identification Low construction High construction M Drawing Dimensions in mm

Stock items in bold type

Panel cut out

Blind wayfor one cable entry

31.15

19 20 032 0537 32

19 20 032 1531 25

19 20 032 0437 32

09 20 032 0302 –

19 20 032 0226 1 x 25

Han HoodsHousings

Hoodsside-entry

Hoodstop-entry

Hoo

ds

Housingsbulkhead mounting

with thermo-plastic cover

1 side-entry with thermo-plastic cover

Housingssurface mountingH

ousi

ngs

Standard Hoods/Housings with metric thread Size 32 A

with 2 levers on the housing for 2 inserts

Part No.

Identification Low construction High construction M Drawing Dimensions in mm

Stock items in bold type

Panel cut out

1) Blind way for one cable entry

31.16

Han HoodsHousings

Standard Hoods with metric thread Size 6 B

with 1 lever on the housing

Stock items in bold type

Part No.

Identification Low construction High construction M Drawing Dimensions in mm

Hoodsside-entry

19 30 006 1540 20

19 30 006 1541 25

19 30 006 0546 25

19 30 006 0547 32

Hoodstop-entry

19 30 006 1440 20

19 30 006 0446 25

19 30 006 0447 32

Hoo

ds

Protection coversfor hoodsmetal

09 30 006 5401

09 30 006 5423

Protection coverfor cable to cable hood

metal 09 30 006 5427

Hoodscable to cable

h

19 30 006 1750 20 42.5

19 30 006 0756 25 72.5

31.17

Han HoodsHousings

Standard Housings with metric thread Size 6 B

with 1 lever on the housing

Part No.

Identification Low construction High construction M Drawing Dimensions in mm

Hou

sing

s

1) Blind way for one cable entry

Panel cut out 48 x 35 mm

a b hLow construction 40 52 54High construction 45 57 74

Housingsbulkhead mounting

09 30 006 0301 –

with thermo-plastic cover

09 30 006 0302 –

with metalcover

09 30 006 0318 –

Housingssurface mounting

19 30 006 1250 1 x 20

19 30 006 1290 2 x 2019 30 006 0291 2 x 2519 30 006 0292 2 x 32

with thermo- with thermo-plastic cover plastic cover

19 30 006 1255 1 x 2019 30 006 1295 2 x 20

19 30 006 0296 2 x 2519 30 006 0297 2 x 32

with withmetal cover metal cover

19 30 006 2255 1 x 2019 30 006 2295 2 x 20

19 30 006 7296 2 x 25

Protection coversmetal

09 30 006 5404

09 30 006 5425

Stock items in bold type

31.18

*

*

Han HoodsHousings

Standard Hoods with metric thread Size B

with 2 levers on the housing

Part No.

Identification Size Low construction High construction M Drawing Dimensions in mm

Stock items in bold type

Low con- High con-Size a struction struction

h h

10 B 73.0 57.0 72

16 B 93.5 62.5 76

24 B 120.5 62.5 76

Low con- High con-Size a struction struction

h h

10 B 73.0 45 72

16 B 93.5 45 76

24 B 120.5 55 76

Size a b c

10 B 74.0 78.5 28.5

16 B 94.5 99.0 44.0

24 B 121.0 125.5 44.0

Hoodsside-entry

10 19 30 010 1520 2010 19 30 010 1521 2510 19 30 010 0527 32

16 19 30 016 1521 2516 19 30 016 1522 19 30 016 0527 3216 19 30 016 0528 40

24 19 30 024 1521 2524 19 30 024 1522 19 30 024 0527 3224 19 30 024 0528 40

Hoodstop-entry

10 19 30 010 1420 2010 19 30 010 1421 2510 19 30 010 0427 32

16 19 30 016 1421 2516 19 30 016 1422 19 30 016 0427 3216 19 30 016 0428 40

24 19 30 024 1422 19 30 024 0427 3224 19 30 024 0428 40

Protection coversthermoplastic/metal

10 09 30 010 540110 09 30 010 5423

16 09 30 016 540116 09 30 016 5422

24 09 30 024 540124 09 30 024 5422

* 10 B: housing width 43 mm

* 10 B: housing width 43 mm

31.19

10 09 30 010 0301 –

16 09 30 016 0301 –

24 09 30 024 0301 –

10 19 30 010 1230 1 x 2010 19 30 010 1231 19 30 010 0231 1 x 2510 19 30 010 1270 2 x 2010 19 30 010 0271 2 x 2510 19 30 010 0272 2 x 32

16 19 30 016 1231 1 x 2516 19 30 016 0232 1 x 3216 19 30 016 1271 19 30 016 0271 2 x 2516 19 30 016 0272 2 x 3210 19 30 016 0273 2 x 40

24 19 30 024 1231 1 x 2524 19 30 024 0232 1 x 3224 19 30 024 1271 2 x 2524 19 30 024 0272 2 x 3224 19 30 024 0273 2 x 40

10 09 30 010 540710 09 30 010 5425

16 09 30 016 540516 09 30 016 5425

24 09 30 024 540524 09 30 024 5425

10 19 30 010 1730 2010 19 30 010 0736 2510 19 30 010 0737 32

16 19 30 016 1731 19 30 016 0736 2516 19 30 016 1732 19 30 016 0737 32

24 19 30 024 1732 19 30 024 0737 3224 19 30 024 0738 40

10 09 30 010 5427

16 09 30 016 5426

24 09 30 024 5426

10 B 83 93 60 x 35

16 B 103 113 82 x 35

24 B 130 140 108 x 35

Standard Housings with metric thread Size B

with 2 levers on the housing

Part No.

Identification Size Low construction High construction M Drawing Dimensions in mm

Size a b Panel cut out

Housings bulkhead mounting

Han HoodsHousings

10 Blow 82 94 40 52 54

high 82 94 45 57 81

16 Blow 105 117 45 57 56

high 105 117 45 57 81

24 Blow 132 144 45 57 56

high 132 144 45 57 81

10 Blow 73,0 47.5

high 73,0 74.5

16 Blow 93.5 47.5

high 93.5 78.5

24 Blow 120,0 57.5

high 120,0 78.5

Size b c

Housings surface mounting

Protection coversfor housingsbulkhead and surface mounting

Thermoplastic/metal

Hoodscable to cable

Stock items in bold type

con-Size a b c d hstruction

Size a b

10 B 74,0 78.5

16 B 94.5 99,0 ,0

24 B 121,0 125.5 ,0

con-Size a hstruction

10 B 78.5 28.5

16 B 99,0 44,0

24 B 125.5 44,0

Protection coversfor hoodscable to cable

Blind way for one cable entry

31.20

10 19 30 010 1540 2010 19 30 010 1541 2510 19 30 010 0547 32

16 19 30 016 1541 2516 19 30 016 1542 19 30 016 0547 3216 19 30 016 0548 40

24 19 30 024 1541 2524 19 30 024 1542 19 30 024 0547 3224 19 30 024 0548 40

10 19 30 010 1440 2010 19 30 010 1441 2510 19 30 010 0447 32

16 19 30 016 1441 2516 19 30 016 1442 19 30 016 0447 3216 19 30 016 0448 40

24 19 30 024 1442 19 30 024 0447 3224 19 30 024 0448 40

*

*

Standard Hoods with metric thread Size B

with 1 lever on the housing

Part No.

Identification Size Low construction High construction M Drawing Dimensions in mm

Han HoodsHousings

Hoodsside-entry

Hoodstop-entry

Stock items in bold type

Low con- High con-Size a struction struction

h h

10 B 73.0 57.5 72

16 B 93.5 62.5 76

24 B 120.5 62.5 76

Low con- High con-Size a struction struction

h h

10 B 73.0 45 72

16 B 93.5 45 76

24 B 120.5 55 76

* 10 B: housing width 43 mm

* 10 B: housing width 43 mm

31.21

*

Han HoodsHousings

Standard Hoods/Housings with metric thread Size B

with 1 lever on the housing

Part No.

Identification Size Low construction High construction M Drawing Dimensions in mm

Housingsbulkhead mounting 10 09 30 010 0305 –

16 09 30 016 0307 –24 09 30 024 0307 –

with thermo-plastic cover

10 09 30 010 0303 –16 09 30 016 0306 –24 09 30 024 0304 –

with metal cover

10 09 30 010 0318 –16 09 30 016 0318 –24 09 30 024 0318 –

Size a b Panel cut out

10 B 83 93 60 x 35

16 B 103 113 82 x 35

24 B 130 140 108 x 35

Stock items in bold type

Housingssurface mounting 10 19 30 010 1250 1 x 20

10 19 30 010 1290 2 x 2010 19 30 010 0291 2 x 2510 19 30 010 0292 2 x 3216 19 30 016 1251 1 x 25

19 30 016 0252 1 x 3216 19 30 016 1291 19 30 016 0291 2 x 2516 19 30 016 0292 2 x 3224 19 30 024 1251 1 x 2524 19 30 024 1291 2 x 2524 19 30 024 0292 2 x 32

with thermo- with thermo-plastic cover plastic cover

10 19 30 010 1255 1 x 2010 19 30 010 1295 2 x 2010 19 30 010 0296 2 x 2510 19 30 010 0297 2 x 3216 19 30 016 1256 1 x 2516 19 30 016 1296 2 x 2516 19 30 016 0297 2 x 3224 19 30 024 1256 1 x 2524 19 30 024 1296 2 x 2524 19 30 024 0297 2 x 32

with metal with metal cover cover

10 19 30 010 2295 2 x 2010 19 30 010 7296 2 x 2516 19 30 016 2296 2 x 2516 19 30 016 7297 2 x 3224 19 30 024 2296 2 x 2524 19 30 024 7297 2 x 32

Hoodcable to cable

10 19 30 010 1750 2010 19 30 010 0756 25

16 19 30 016 1751 2516 19 30 016 1752 19 30 016 0757 32

24 19 30 024 1752 19 30 024 0757 32

1) Blind way for one cable entry

Size Construction a b c d

10 Blow 82 94 40 52high 82 94 45 57

16 B low/high 105 117 45 5724 B low/high 132 144 45 57

Size Construction e f g h

10 Blow 18 22 67 54high 18 20 65 81

16 Blow 18 20 65 56high 18 20 65 81

24 Blow 18 20 65 56high 18 20 65 81

* high construction 16 B, 24 B: without mol-ded adapter and housing width 45 mm

h hSize a b low high

10 B 73.5 89 47.5 74.5

16 B 93.5 110 47.5 78.5

24 B 120.5 137 57.5 78.5

31.22

Han HoodsHousings

Standard Hoods/Housings with metric thread Size B

with 2 levers on the housing

Part No.

Identification Size Low construction High construction M Drawing Dimensions in mm

Hoodsside-entry 10 19 30 010 1530 20

10 19 30 010 0537 32

16 19 30 016 1531 2516 19 30 016 0537 3216 19 30 016 0538 40

24 19 30 024 1531 2524 19 30 024 0537 3224 19 30 024 0538 40

Hoodstop-entry 10 19 30 010 1430 20

10 19 30 010 0436 25

16 19 30 016 1431 2516 19 30 016 1432 19 30 016 0437 3216 19 30 016 0438 40

24 19 30 024 1432 19 30 024 0437 3224 19 30 024 0438 40

Hoo

ds

Housingsbulkhead mounting with thermo-

plastic cover

10 09 30 010 030216 09 30 016 030224 09 30 024 0302

with metal cover

10 09 30 010 031716 09 30 016 031724 09 30 024 0317

Hou

sing

s

Panel cut out

Hoodsflat cableentry

16 09 30 016 4431

Size a b c

10 83 93 60

16 103 113 82

24 130 140 108

Low HighSize a construction construction

h c h c

10 73.5 57.5 43 72 43

16 93.5 62.5 45 76 45

24 120.5 62.5 45 76 45

1) Blind way for one cable entry

Low HighSize a construction construction

h c h c

10 73.5 45 43 72 43

16 93.5 45 45 76 45

24 120.5 55 45 76 45

Housingssurface mounting

with thermo- with thermo-plastic cover plastic cover

10 19 30 010 1225 1 x 2010 19 30 010 1265 2 x 2010 19 30 010 0266 2 x 25

16 19 30 016 1226 1 x 2516 19 30 016 1266 2 x 2516 19 30 016 0267 2 x 32

24 19 30 024 1226 1 x 2524 19 30 024 1266 2 x 2524 19 30 024 0267 2 x 32

Stock items in bold type

a = see above

Con-Size a b c d f g hstruction

10low 82 94 40 52 22 67 54high 82 94 45 57 20 65 81

16low 105 117 45 57 20 65 56high 105 117 45 57 20 65 81

24low 132 144 45 57 20 65 56high 132 144 45 57 20 65 81

31.23

*

6 19 30 006 0586 25

10 19 30 010 0586 25

16 19 30 016 0586 2516 19 30 016 0587 32

24 19 30 024 0586 2524 19 30 024 0587 3224 19 30 024 0588 40

16 19 30 016 0487 32

24 19 30 024 0487 32

10 09 30 010 0381

16 09 30 016 0381

24 09 30 024 0381

16 19 30 016 0282 2 x 32

24 19 30 024 0282 2 x 32

16 105 117 81

24 132 144 81

Size a b h

10 83 93 60 x 35

16 103 113 82 x 35

24 130 140 108 x 35

Size a b Panel cut out

Hoods/Housings with metric thread Size B

Identification Size Part No. M Drawing Dimensions in mm

Hou

sing

sH

oods

Stock items in bold type

Han HoodsHousings

with central locking lever

Hoodsside-entry

Hoodstop-entry

Housingsbulkhead mounting

Housingssurface mounting

10 73.0 70

16 93.5 76

24 120.0 87

Size a b

16 93.5 76

24 120.0 87

Size a b

* 10 B: housing width43 mm

31.24

19 30 032 0527 3219 30 032 0528 4019 30 032 0529 50

09 30 032 0301 –

19 30 032 0427 3219 30 032 0428 4019 30 032 0429 50

19 30 032 0232 1 x 3219 30 032 0272 2 x 3219 30 032 0273 2 x 40

19 30 032 0738 40

09 30 032 5425 –

09 30 032 5420 –

Han HoodsHousings

Standard Hoods/Housings with metric thread Size 32 B

with 2 levers on the housing for 2 inserts

Identification Part No. M Drawing Dimensions in mm

Hoodsside-entry

Housingbulkhead mounting

Hou

sing

sH

oods

Hoodstop-entry

Housingssurface mounting

Hoodcable to cable

Protection covers

for housings

Panel cut out

Protection coverfor hoods

Stock items in bold type

31.25

Han HoodsHousings

Standard Hoods/Housings with metric thread Size 48 B

with 1 lever on the housing for 2 inserts

Identification Part No. M Drawing Dimensions in mm

Hoodsside-entry

19 30 048 0548 4019 30 048 0549 50

Housingsbulkhead mounting

with thermo-plastic cover

09 30 048 0301 –

with metal cover

09 30 048 0317 –

Hou

sing

sH

oods

Hoodstop-entry

19 30 048 0448 4019 30 048 0449 50

Housingssurface mounting 2 side-entries

19 30 048 0292 2 x 3219 30 048 0293 2 x 40

with thermo-plastic cover

19 30 048 0298 2 x 40

1) Blind grommet

Panel cut out

Stock items in bold type

31.26

09 37 003 0801

09 37 003 0301

19 37 003 1250 20

19 37 003 1750 20

09 37 003 54021)

09 37 003 54012)

09 37 003 54052)

09 37 003 54061)

19 37 003 1640 20

19 37 003 1150 20

19 37 003 1440 20

Han HoodsHousings

Hoods/Housings Han® M with metric thread Size 3 A

for harsh environmental requirements

Identification Part No. M Drawing Dimensions in mm

1) for mounted male insert 2) for mounted female insert Stock items in bold type

Hoo

dsH

ousi

ngs

Housings bulkhead mounting

Housingsurface mounting 1 side-entry

Hood cable to cable

Housing screw mounting

Protection coversfor hoods

Protection coverfor housings

Panel cut out 22 x 22 mm

Panel cut out22 x 22 mm

Hoodsside-entry

Hoodstop-entry

31.27

19 37 006 1540 19 37 006 0545 2019 37 006 0546 25

19 37 006 1440 19 37 006 0445 2019 37 006 0446 25

09 37 006 5405

09 37 006 0301 –

09 37 006 0318 –

19 37 006 1290 2 x 20

19 37 006 0296 25

Han HoodsHousings

Hoods/Housings Han® M with metric thread Size 6 B

for harsh environmental requirements

Stock items in bold type

Hoodside-entry

Hoodstop-entry

Protection covermetal

Housingbulkhead mounting

Housingsurface mounting 2 side-entries

Hou

sing

sH

oods

Panel cut out

with metalcover

with thermo-plastic cover

Part No.

Identification Low construction High construction M Drawing Dimensions in mm

31.28

10 19 37 010 0465 2 x 20

10 19 37 010 0447 32

10 19 37 010 0291 25

Han HoodsHousings

Hoods/Housings Han® M with metric thread Size B

Identification Size Part No. Pg Drawing Dimensions in mm

Hoodsfor special applications

top-entry

Hoodstop-entry

Stock items in bold type

31.29

16 19 37 016 0587 32

24 19 37 024 0587 32

16 19 37 016 0487 32

24 19 37 024 0487 32

24 09 37 024 0381

16 19 37 016 0282 2 x 32

24 19 37 024 0282 2 x 32

16 105 117 81

24 132 144 81

24 130 140 108 x 35

Han HoodsHousings

Hoodsside-entry

Hoodstop-entry

Housingsbulkhead mounting

Housingssurface mounting

16 93.5 76

24 120.0 87

Size a b h

Size a b

16 93.5 76

24 120.0 87

Size a b

Size a b Panel cut out

Hoods/Housings Han® M with metric thread Size B

with central locking lever

Identification Size Part No. M Drawing Dimensions in mm

Hou

sing

sH

oods

Stock items in bold type

31.30

h a

h a

a

a b c

h a b c d

a

24 19 37 024 0733 40

Han HoodsHousings

Hoods/Housings Han® M with metric thread Size B

for harsh environmental requirements

Part No.Identification Size low construction high construction M Drawing Dimensions in mm

Stock items in bold type

10 09 37 010 0301 – 83 93 60

16 09 37 016 0301 – 103 113 82

24 09 37 024 0301 – 130 140 108

10 19 37 010 1270 2 x 20 54 82 94 40 5210 19 37 010 0272 2 x 32 81 82 94 45 57

16 19 37 016 1231 1 x 25 56 105 117 45 5716 19 37 016 0272 2 x 32 81 105 117 45 57

24 19 37 024 0272 2 x 32 81 132 144 45 57

10 19 37 010 1520 20 52.0 73.510 19 37 010 0526 25 72.0 73.0

16 19 37 016 1521 25 62.5 93.516 19 37 016 0527 32 76.0 93.516 19 37 016 0528 40 76.0 97.5

24 19 37 024 1521 25 60.0 120.524 19 37 024 0527 32 76.0 120.524 19 37 024 0528 40 76.0 120.0

Hoodsside-entry

Hoo

ds

Protection coversmetal

10 19 37 010 1420 20 45 73.010 19 37 010 0427 32 72 73.0

16 19 37 016 1421 25 45 93.516 19 37 016 0427 32 76 93.5

24 19 37 024 1421 25 55 120.024 19 37 024 0427 32 76 120.024 19 37 024 0428 40 76 120.0

Hoodstop-entry

10 09 37 010 5403 – 79.0

16 09 37 016 5402 – 99.5

24 09 37 024 5402 – 126.0

Housingsbulkhead mounting

Hou

sing

s

Panel cutout

Housingssurface mounting

10 09 37 010 5405 – 79.5

16 09 37 016 5405 – 99.5

24 09 37 024 5405 – 126.5

Protection coversmetal

Hoodcable to cablemetal

31.31

19 37 048 0548 40

09 37 048 0301 –

19 37 048 0448 4019 37 048 0449 50

19 37 048 0401 4 x 25

Han HoodsHousings

Hoods/Housings Han® M with metric thread Size 48 B

with 1 lever on the housing for 2 inserts

Identification Part No. M Drawing Dimensions in mm

Hoodsside-entry

with thermo-plastic cover

Housingsbulkhead mounting

Hou

sing

sH

oods

Hoodstop-entry

Hoodstop-entry

Panel cut out

Stock items in bold type

3 A 19 40 003 0400 19 40 003 0410 20

3 A 09 40 003 0301 09 40 003 0311

3 A 19 40 003 0950 20

3 A 09 40 003 0950 –

3 A 09 40 003 0902 –

3 A 19 40 003 0900 20

31.32

Han HoodsHousings

Han® 3 HPR with metric thread Size 3 A

Part No.Identification Size Screw locking M Drawing Dimensions in mm

Accessories Size Part No. M Drawing Dimensions in mm

Hoodtop-entrywith sealing screw*

Housingbulkhead mountingwith sealing screw*

Housingsbulkhead and surfa-ce mountingwith sealing screw*

Adaptorfor assembly in angledposition

Stock items in bold type* Sealing on the insert has to be removed

Seal screw

Seal screw

Panel cut out 21.3 x 21.3 mm

closed

open

Seal screw

31.33

6 19 40 006 0510 20

6 19 40 006 0501 19 40 006 0511 256 19 40 006 0512 32

10 19 40 010 0501 19 40 010 0511 2510 19 40 010 0512 32

16 19 40 016 0502 19 40 016 0512 3216 19 40 016 0513 4016 19 40 016 0514 50

24 19 40 024 0512 3224 19 40 024 0503 19 40 024 0513 4024 19 40 024 0514 5024 19 40 024 0537 2 x 32

6 19 40 006 0410 206 19 40 006 0401 19 40 006 0411 256 19 40 006 0412 326 19 40 006 0413 40

10 19 40 010 0401 19 40 010 0411 2510 19 40 010 0412 3210 19 40 010 0430 2 x 20

16 19 40 016 0411 2516 19 40 016 0402 19 40 016 0412 3216 19 40 016 0413 4016 19 40 016 0414 5016 19 40 016 0431 2 x 25

24 19 40 024 0402 19 40 024 0412 3224 19 40 024 0413 4024 19 40 024 0414 5024 19 40 024 0432 2 x 3224 19 40 024 0433 2 x 4024 19 40 024 0461 3 x 25

24 19 40 024 0420 63

24 19 40 024 0419 5024 19 40 024 0467 3 x 32

6 B 133 101

10 B 146 101

16 B 166 111

24 B 193 111

6 B 133 101

10 B 146 101

16 B 166 111

24 B 193 111

Han HoodsHousings

Hoods/Housings Han® HPR Size B

Part No.

Identification Size Screw locking M Drawing Dimensions in mm

Hoodsside-entry

Hoodstop-entry

Hoodtop-entry

Stock items in bold type

Size a h

Size a h

31.34

6 09 40 006 0301 09 40 006 0311

10 09 40 010 0301 09 40 010 0311

16 09 40 016 0301 09 40 016 0311

24 09 40 024 0301 09 40 024 0311

6 09 40 006 5401 09 40 006 5411

10 09 40 010 5401 09 40 010 5411

16 09 40 016 5401 09 40 016 5411

24 09 40 024 5401 09 40 024 5411

6 09 40 000 9901

10 09 40 000 9902

16 09 40 000 9903

24 09 40 000 9904

6 B 70 133 48

10 B 83 146 60

16 B 103 166 82

24 B 130 193 108

6 B 70 96

10 B 83 109

16 B 103 129

24 B 130 156

6 B 133

10 B 146

16 B 166

24 B 193

6 19 40 006 1260 1 x 206 19 40 006 1261 1 x 256 19 40 006 1262 1 x 32

10 19 40 010 1260 1 x 2010 19 40 010 1262 1 x 32

16 09 40 016 1201 –16 19 40 016 1262 1 x 3216 19 40 016 1263 1 x 4016 19 40 016 1273 2 x 40

24 19 40 024 1263 1 x 4024 19 40 024 1273 2 x 40

6 B 127 156

10 B 140 169

16 B 160 189

24 B 187 216

Han HoodsHousings

Hoods/Housings Han® HPR with metric thread Size B

Part No.

Identification Size Toggle locking Screw locking M Drawing Dimensions in mm

Housingsbulkhead mounting

Stock items in bold type

Protection covers

Mounting frames

Size a b c

Size a b

Housingssurface mounting

Size a b

Size a

31.35

19 62 003 1640 20

19 62 003 1440 20

09 62 003 0801

09 62 003 0301

19 62 003 1250 20

19 62 003 1750 20

Han HoodsHousings

Stock items in bold type

Hoods/Housings Han® EMC with metric thread Size 3 A

Identification Part No. M Drawing Dimensions in mm

Hoo

ds

Hoodside-entry

Hoodtop-entry

Hou

sing

s

Housingsbulkhead mounting

Panel cut out 22 x 22 mm

Housingsurface mounting

1 side-entry

Panel cut out 22 x 22 mm

Hoodcable to cable

1 side-entry

31.36

Han HoodsHousings

Hoods/Housings Han® EMC with metric thread Size 10 A, 16 A

Identification Size Part No. Pg Drawing Dimensions in mm

Hoodsside-entry

10 A 19 62 015 0546 25

16 A 19 62 025 0546 25

Hoodstop-entry

10 A 19 62 015 0446 25

16 A 19 62 025 0446 25

Housingsbulkhead mounting

10 A 09 62 015 0301

16 A 09 62 025 0301

Size a h

10 A 64 70

16 A 80 70

Size a h

10 A 64 70

16 A 80 70

Size a b Panel cut out

10 A 81 70 24 x 57

16 A 96 86 24 x 73

Stock items in bold type

Hoo

dsH

ousi

ngs

31.37

6 19 62 006 0541 25

10 19 62 010 0542 32

16 19 62 040 0542 32

24 19 62 064 0543 40

6 19 62 006 0441 256 19 62 006 0442 32

10 19 62 010 0442 32

16 19 62 040 0442 32

24 19 62 064 0443 40

6 09 62 006 0301

10 09 62 010 0301

16 09 62 040 0301

24 09 62 064 0301

Han HoodsHousings

Hoods/Housings Han® EMC with metric thread Size B

Identification Size Part No. M Drawing Dimensions in mm

Hoodsside-entry

Hoodstop-entry

Housings bulkhead mounting

Hou

sing

sH

oods

Size a b h

6 72 – 75

10 85 76 75

16 106 86 75

24 132 100 85

Size a h

6 72 75

10 85 75

16 106 75

24 132 85

Stock items in bold type

Size a b Panel cut out6 80 70 48 x 35

10 93 83 60 x 3516 113 103 82 x 3524 140 130 108 x 35

31.38

10 19 62 810 1520 2010 19 62 810 0526 2510 19 62 810 0527 32

16 19 62 816 1521 2516 19 62 816 0527 32

24 19 62 824 1521 2524 19 62 824 0527 3224 19 62 824 0528 40

6 19 62 806 1540 206 19 62 806 0546 256 19 62 806 0547 32

10 19 62 810 0547 32

06 09 62 806 0301 –

10 09 62 810 0301 –

16 09 62 816 0301 –

24 09 62 824 0301 –

10 19 62 810 0757 32

10 19 62 810 1420 2010 19 62 810 1421 2510 19 62 810 0426 2510 19 62 810 0427 32

16 19 62 816 1421 2516 19 62 816 0427 32

24 19 62 824 1422 19 62 824 0427 32

6 19 62 806 1440 206 19 62 806 0446 256 19 62 806 0447 32

10 19 62 810 0446 2510 19 62 810 0447 32

6 B 70 80 48 x 3510 B 83 93 60 x 3516 B 103 113 82 x 3524 B 130 140 108 x 35

6 19 62 806 1290 2 x 20

10 19 62 810 1271 2 x 2510 19 62 810 0272 2 x 32

16 19 62 816 1271 2 x 2516 19 62 816 0273 2 x 40

24 19 62 824 1271 2 x 2524 19 62 824 0273 2 x 40

6 B 70 8210 B 82 9416 B 105 11724 B 132 144

Hoods/Housings Han® EMC with metric thread Size B

with 2 levers on the housing

Part No.

Identification Size Low construction High construction M Drawing Dimensions in mm

with double lever

Hoodsside-entry

with singlelever

Hoodstop-entry

with singlelever

Hoodscable to cable

with double lever

Low HighSize a construction h construction h

6 B 60.0 43.0 7210 B 73.0 57.0 7216 B 93.5 62.5 7624 B 120.5 62.5 76

Low HighSize a construction h construction h

6 B 60.0 40 7210 B 73.0 45 7216 B 93.5 55 7624 B 120.5 55 76

Han HoodsHousings

Stock items in bold type

Housingsbulkhead mountingwith 2 locking leversand 1 adapter frame

Size 6 Bwith 1 locking lever only

Housingssurface mounting

Size a b Panel cut out

Size a b

31.39

*

*

*

*

Han HoodsHousings

Hoods/Housings with metric thread Size B

for special applications

Identification Size Part No. Pg Drawing Dimensions in mm

Hoodstop-entry

10 19 30 010 0465 2 x 20

16 19 30 016 0466 2 x 25

24 19 30 024 0467 2 x 32

Hoodsside-entry

16 19 30 016 0666 2 x 25

24 19 30 024 0666 2 x 25

Hoodswithout entryfor customized drillings

double lever 6 09 30 006 0801 –

10 09 30 010 0801 –

16 09 30 016 0801 –

24 09 30 024 0801 –

single lever 10 09 30 010 0803 –

16 09 30 016 0803 –

24 09 30 024 0803 –

Flange housing6 19 30 006 0716 1 x 25

10 73,0 72 20 2 x 20

16 93.5 76 36 2 x 32

24 120,0 76 52 2 x 25

Size a h x M

Size a x M

16 93.5 36 2 x 25

24 120.0 56 2 x 25

Size a h

10 73.0 72

16 93.5 76

24 120.0 76

Stock items in bold type

* 10 B:housingwidth 43 mm

* 10 B:housing width 43 mm

* 10 B:housing width 43 mm

Han® Standard Hood

Technical Details Features

Identification Part-Number M Drawing Dimensionsinmm

Material Die cast aluminiumSurface Powder coated RAL 7037Locking element V2A SteelSeal NBRLimiting temperatures -40°C . . . +125°CDegree of protection accd . to DIN EN 60 529 for coupled connector IP 65

• Extended height• Big wiring space• Optimised 30° angle for cable entry• Compatible with standard housings

Hood top entry with 2 levers on the housing

Hood side entry with 2 levers on the housing

Hood side entry with 1 central lever

19 30 024 0429

19 30 024 0529

19 30 024 0589

50

50

50

M50, Size 24 B

11 30 016 0520

11 30 024 0520

11 30 000 9954

11 30 000 9955

11 30 000 9956

11 30 000 9957

11 30 000 9958

11 30 000 9959

Han® Easy-Hood

16 B

24 B

_

_

_

_

_

_

Identification Partnumber Size Drawing Dimensionsinmm

Advantages Technical characteristics• Optimised handling for big wires or multiple cables• Reduced wiring times• Visible wiring• Integrated cable gland• Cord grip• Captive screws• Optimised cable entry

Material Aluminium die-castSurface powder-coated RAL 7037 (grey)Seal NBRLimiting temperatures -40 / +85°CDegree of protection accd . to DIN 60 529 IP 65

Packagingcontentupper hood, lower hood, 3fixingscrews,cordgrip, 2screwsforclampfixing, 2 adaptors for guide pins and bushes

Han® Easy-Hood

Han® Easy-Hood side entry

Cable seal 17 - 19 mm

Cable seal 20 - 22 mm

Cable seal 23 - 25 mm

Cable seal 26 - 28 mm

Cable seal 29 - 31 mm

Cable seal 32 - 34 mm

Size B

Size a b c

16 B 100 mm 94 mm 112 mm

24 B 108 mm 120 .5 mm 139 mm

Han® Easy-Hood

0,8 Nm

AB

The Han® Easy-Hood offers a vertical split into two shells with new assembling possibilities . Assembly processes can be changed to much more modular production steps with new logistics . The wiring can be controlled . All manual movements changed from axial to vertical processes leading to automation possibilities .

Technical Description

Size B

Notewhenusingguidepins/bushes:When using guide pins / bushes the user needs to apply the adaptors „A“ on both sides of the insert „B“ . The recommended tightening torque is 0 .8 Nm . Afterwards the insert can be placed in the Han® Easy-Hood .

2 Nm

2 Nm

31.40

Notes

Han HoodsHousings