February 15, 2008 Mr. Max Boone ConocoPhillips Company 1230 W. Washington St., Suite 212 Tempe, Arizona 85281 RE: Due Diligence Site Assessment Report ConocoPhillips Site No. 2705492 21208 68 th Avenue South Kent, Washington ATC Project No. 34.75118.3328 Dear Mr. Boone: ATC Associates Inc. (ATC) on behalf of ConocoPhillips Company (ConocoPhillips) presents the results of a Due Diligence Site Assessment conducted at the above-referenced site. The purpose of the investigation was to generate a baseline assessment of property conditions at the time of property transfer. The data reported herein was collected on behalf of ConocoPhillips, in general accordance with the Site-Specific Scope of Work (SOW) prepared by Shaw Environmental & Infrastructure, Inc. (Shaw) dated November 2, 2007 (Appendix A, attached). The data reported herein was not requested or required by a regulatory agency. Activities included in the SOW performed are outlined below: Preparation of a site specific Health and Safety Plan (HASP); Securing permits, if applicable, from the local permitting agency; Collection of post-purge groundwater samples for laboratory analysis from existing on-site monitor wells MW-1, MW-4, MW-5, MW-6, MW-7, TW-1 and TW-3 (a sample was not collected from monitor well TW-4 as it was unable to be opened); Waste profiling and disposal coordination (still underway); and Preparation of a report summarizing due diligence assessment activities. SITE DESCRIPTION The site is an active service station located at 21208 68 th Avenue South in Kent, Washington. The site’s current underground storage tank (UST) system configuration includes three fuel USTs and four dispenser islands. Limited background information is included in the SOW prepared by Shaw (Appendix A). 9185 South Farmer Avenue, Suite 107 Tempe, Arizona 85284 www.atcassociates.com 480.894.2056 fax 480.894.2497

ConocoPhillips Company - Wa

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

February 15, 2008 Mr. Max Boone ConocoPhillips Company 1230 W. Washington St., Suite 212 Tempe, Arizona 85281 RE: Due Diligence Site Assessment Report ConocoPhillips Site No. 2705492 21208 68th Avenue South

Kent, Washington ATC Project No. 34.75118.3328

Dear Mr. Boone:

ATC Associates Inc. (ATC) on behalf of ConocoPhillips Company (ConocoPhillips) presents the results of a Due Diligence Site Assessment conducted at the above-referenced site. The purpose of the investigation was to generate a baseline assessment of property conditions at the time of property transfer. The data reported herein was collected on behalf of ConocoPhillips, in general accordance with the Site-Specific Scope of Work (SOW) prepared by Shaw Environmental & Infrastructure, Inc. (Shaw) dated November 2, 2007 (Appendix A, attached). The data reported herein was not requested or required by a regulatory agency.

Activities included in the SOW performed are outlined below:

• Preparation of a site specific Health and Safety Plan (HASP); • Securing permits, if applicable, from the local permitting agency; • Collection of post-purge groundwater samples for laboratory analysis from

existing on-site monitor wells MW-1, MW-4, MW-5, MW-6, MW-7, TW-1 and TW-3 (a sample was not collected from monitor well TW-4 as it was unable to be opened);

• Waste profiling and disposal coordination (still underway); and • Preparation of a report summarizing due diligence assessment activities.

SITE DESCRIPTION

The site is an active service station located at 21208 68th Avenue South in Kent, Washington. The site’s current underground storage tank (UST) system configuration includes three fuel USTs and four dispenser islands. Limited background information is included in the SOW prepared by Shaw (Appendix A).

9185 South Farmer Avenue, Suite 107Tempe, Arizona 85284

www.atcassociates.com480.894.2056

fax 480.894.2497

ConocoPhillips Site No. 2705492 February 15, 2008 Page 2

2705492 Report

BASELINE SITE ASSESSMENT

Field Activities

On January 9, 2008, ATC personnel gauged and collected groundwater samples from existing on-site monitor wells MW-1, MW-4, MW-5, MW-6, MW-7, TW-1 and TW-3 shown on the attached Figure 1, Site Plan. Depth to groundwater in the wells ranged from 7.58 feet (MW-7) to 8.43 feet (MW-1 and MW-4) below the top of the well casing. One to three volumes of groundwater were purged from each monitoring well using a battery-operated pump during which time temperature, pH, and electrical conductivity were monitored to verify that groundwater conditions had stabilized prior to sample collection. Groundwater samples were then collected using disposable polyethylene bailers and transferred from the bailers into sample containers provided by the analytical laboratory. Groundwater sampling observations were recorded and are included as Appendix B, attached.

Laboratory Analytical Procedures

Groundwater samples collected during field activities were shipped under chain-of-custody (COC) protocol to Lancaster Laboratories, Inc. (Lancaster) in Lancaster, Pennsylvania. Lancaster is certified through the State of Washington Department of Ecology. Groundwater samples collected from monitor wells MW-1, MW-4, MW-5, MW-6, MW-7, TW-1 and TW-3 were analyzed for fuel oxygenates and halogenated volatile organic compounds (HVOC; including benzene, toluene, ethylbenzene and total xylenes [BTEX]) using Environmental Protection Agency (EPA) Method 8260B. Each sample selected was also analyzed for gasoline-, diesel- and heavy range organic-petroleum hydrocarbons using Northwest Total Petroleum Hydrocarbons (NWTPH) Modified method (NWTPH-Gx [C8 to C12], NWTPH-Dx DRO [C12 to C24] and NWTPH-Dx HRO [C>24 to C40], respectively). Additionally, the groundwater samples were analyzed for lead using EPA Method 6020. Laboratory analytical data for groundwater samples analyzed as part of this assessment are summarized in attached Table 1, Summary of Groundwater Analytical Data. The laboratory analytical report and COC document are provided as Appendix C, attached.

Waste Disposal

Investigation derived waste (IDW) generated during the field operations has been temporarily stored onsite pending characterization and disposal. A copy of the waste manifest(s) will be provided under separate cover once the IDW has been profiled and transported to an appropriate disposal facility.

FINDINGS

As shown in Table 1, laboratory analytical results for the groundwater samples selected for analysis indicate the following:

• Benzene was detected at a concentration of 150 micrograms per liter (μg/L) in the groundwater sample collected from monitor well TW-1.

ConocoPhillips Site No. 2705492 February 15, 2008 Page 3

2705492 Report

• Toluene was detected at a concentration of 17 μg/L in the groundwater sample collected from monitor well TW-1.

• Ethylbenzene was detected at a concentration of 87 μg/L in the groundwater sample collected from monitor well TW-1.

• Total xylenes were detected at a concentration of 195 μg/L in the groundwater sample collected from monitor well TW-1.

• Chlorobenzene was detected at a concentration of 1 J μg/L in the groundwater sample collected from monitor well TW-1.

• 1,2 – Dichlorobenzene was detected at a concentration of 2 J μg/L in the groundwater sample collected from monitor well TW-1.

• t-Butyl alcohol was detected at a concentration of 13 J μg/L in the groundwater sample collected from monitor well MW-4.

• NWTPH-Gx was detected at concentrations of 69 J μg/L, 88 J μg/L and 2,200 μg/L in the groundwater samples collected from monitor wells MW-1, MW-4 and TW-1, respectively.

• NWTPH-Dx DRO was detected at concentrations of 230 J μg/L and 370 J μg/L in the groundwater samples collected from monitor wells MW-4 and TW-1, respectively.

• Lead was detected at concentrations of 0.29 J μg/L, 1.5 μg/L and 1.7 μg/L in the groundwater samples collected from monitor wells MW-4, TW-1 and TW-3, respectively.

• No other analytes were detected in excess of their respective laboratory method detection limit (MDL) in any of the groundwater samples submitted for analysis.

It should be noted that the “J” notation after the analyte value indicates an estimated concentration between the laboratory MDL and the limit of quantitation.

LIMITATIONS

This report was prepared in general accordance with the Shaw SOW dated November 2, 2007, and with generally accepted professional environmental consulting practices existing at the time this report was prepared and applicable to the location of the site. It was prepared for the exclusive use of ConocoPhillips for the express purpose of generating a baseline assessment of property conditions. Any re-use of this report for a different purpose shall be at the user’s sole risk without liability to ATC. To the extent that this report is based on information provided to ATC by third parties, ATC may have made efforts to verify this third party information; however, ATC cannot guarantee the completeness or accuracy of this information. The data collected during this investigation and summarized in this report represents site conditions at the time field activities were conducted. No other warranties, expressed or implied, are made by ATC.

TABLE

TABLE 1SUMMARY OF GROUNDWATER ANALYTICAL DATA

ConocoPhillips Site No. 270549221208 68th Avenue South, Kent, Washington

Benzene(µg/L)

Toluene(µg/L)

Ethylbenzene(µg/L)

Total Xylenes(µg/L)

Other HVOC * (µg/L)

Oxygenates * (µg/L)

NWTPH-Gx(µg/L)

NWTPH-Dx DRO(µg/L)

NWTPH-Dx HRO

(µg/L)

Lead (µg/L)

EPA 6020

MW-1 01/09/08 <0.5 <0.7 <0.8 <0.8 All analytes ND. All analytes ND. 69 J <76 <95 <0.047

MW-4 01/09/08 <0.5 <0.7 <0.8 <0.8 All analytes ND. t-Butyl alcohol (13 J) 88 J 230 J <94 0.29 J

MW-5 01/09/08 <0.5 <0.7 <0.8 <0.8 All analytes ND. All analytes ND. <50 <76 <95 <0.047

MW-6 01/09/08 <0.5 <0.7 <0.8 <0.8 All analytes ND. All analytes ND. <50 <76 <95 <0.047

MW-7 01/09/08 <0.5 <0.7 <0.8 <0.8 All analytes ND. All analytes ND. <50 <75 <94 <0.047

TW-1 01/09/08 150 17 87 195 Chlorobenzene (1 J)1,4 - Dichlorobenzene (2 J) All analytes ND. 2,200 370 J <190 1.5

TW-3 01/09/08 <0.5 <0.7 <0.8 <0.8 All analytes ND. All analytes ND. <50 <77 <96 1.7

Notes: µg/L - Micrograms per liter (equivalent to parts per billion).HVOC - Halogenated volatile organic compounds.* - Only compounds detected at a concentration exceeding their respective laboratory method detection limit (MDL) are noted.NWTPH-Gx - Gasoline range organic hydrocarbons (C8-C12).NWTPH-Dx DRO - Diesel range organic hydrocarbons (C12-C24).NWTPH-Dx HRO - Heavy range organic hydrocarbons (C>24-C40).EPA - Environmental Protection AgencyNWTPH - Northwest Total Petroleum Hydrocarbons<0.5 - Analyte not detected above specific laboratory MDL.ND - Analyte not detected above specific laboratory MDL.J - Estimated value between laboratory MDL and limit of quantitation.

Sample ID

NWTPH ModifiedEPA 8260B

Sample Date

2705492 Table Table 1 - Soil Data Page 1 of 1

FIGURE

APPENDIX A

SCOPE OF WORK

APPENDIX B

GROUNDWATER SAMPLING LOGS

APPENDIX C

LABORATORY ANALYTICAL REPORT AND

CHAIN-OF-CUSTODY DOCUMENTATION

ANALYTICAL RESULTS

Prepared for:

ConocoPhillipsSuite 212

1230 W. WashingtonTempe AZ 85281

602-452-2502

Prepared by:

Lancaster Laboratories2425 New Holland Pike

Lancaster, PA 17605-2425

SAMPLE GROUP

The sample group for this submittal is 1073037. Samples arrived at the laboratory on Saturday, January 12,2008. The PO# for this group is 4509130449 and the release number is BOONE.

Client Description Lancaster Labs NumberMW-5 Grab Water 5255498MW-6 Grab Water 5255499MW-1 Grab Water 5255500TW-1 Grab Water 5255501MW-7 Grab Water 5255502TW-3 Grab Water 5255503MW-4 Grab Water 5255504

ELECTRONICCOPY TO

ATC Associates Attn: Anita Carrano

ELECTRONICCOPY TO

ATC Associates Attn: Rebekah Wilson

Questions? Contact your Client Services RepresentativeMegan A Moeller at (717) 656-2300

Respectfully Submitted,

Page 1 of 3

Lancaster Laboratories Sample No. 5255498 WW Group No. 1073037

MW-5 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:10 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K05

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

06035 Lead 7439-92-1 N.D. 0.047 1.0 ug/l 1

02211 TPH by NWTPH-Dx(water)w/SiGel

02095 Diesel Range Organics n.a. N.D. 76. 240. ug/l 102096 Heavy Range Organics n.a. N.D. 95. 470. ug/l 1

08273 TPH by NWTPH-Gx waters

01645 TPH by NWTPH-Gx waters n.a. N.D. 50. 250. ug/l 1

05382 EPA SW846/8260 (water)

05385 Chloromethane 74-87-3 N.D. 1. 5. ug/l 105386 Vinyl Chloride 75-01-4 N.D. 1. 5. ug/l 105387 Bromomethane 74-83-9 N.D. 1. 5. ug/l 105388 Chloroethane 75-00-3 N.D. 1. 5. ug/l 105389 Trichlorofluoromethane 75-69-4 N.D. 2. 5. ug/l 105390 1,1-Dichloroethene 75-35-4 N.D. 0.8 5. ug/l 105391 Methylene Chloride 75-09-2 N.D. 2. 5. ug/l 105392 trans-1,2-Dichloroethene 156-60-5 N.D. 0.8 5. ug/l 105393 1,1-Dichloroethane 75-34-3 N.D. 1. 5. ug/l 105395 cis-1,2-Dichloroethene 156-59-2 N.D. 0.8 5. ug/l 105396 Chloroform 67-66-3 N.D. 0.8 5. ug/l 105398 1,1,1-Trichloroethane 71-55-6 N.D. 0.8 5. ug/l 105399 Carbon Tetrachloride 56-23-5 N.D. 1. 5. ug/l 105401 Benzene 71-43-2 N.D. 0.5 5. ug/l 105402 1,2-Dichloroethane 107-06-2 N.D. 1. 5. ug/l 105403 Trichloroethene 79-01-6 N.D. 1. 5. ug/l 105404 1,2-Dichloropropane 78-87-5 N.D. 1. 5. ug/l 105406 Bromodichloromethane 75-27-4 N.D. 1. 5. ug/l 105407 Toluene 108-88-3 N.D. 0.7 5. ug/l 105408 1,1,2-Trichloroethane 79-00-5 N.D. 0.8 5. ug/l 105409 Tetrachloroethene 127-18-4 N.D. 0.8 5. ug/l 105411 Dibromochloromethane 124-48-1 N.D. 1. 5. ug/l 105413 Chlorobenzene 108-90-7 N.D. 0.8 5. ug/l 105415 Ethylbenzene 100-41-4 N.D. 0.8 5. ug/l 105416 m+p-Xylene 1330-20-7 N.D. 0.8 5. ug/l 105417 o-Xylene 95-47-6 N.D. 0.8 5. ug/l 1

Page 2 of 3

Lancaster Laboratories Sample No. 5255498 WW Group No. 1073037

MW-5 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:10 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K05

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

05419 Bromoform 75-25-2 N.D. 1. 5. ug/l 105421 1,1,2,2-Tetrachloroethane 79-34-5 N.D. 1. 5. ug/l 105432 1,3-Dichlorobenzene 541-73-1 N.D. 1. 5. ug/l 105433 1,4-Dichlorobenzene 106-46-7 N.D. 1. 5. ug/l 105435 1,2-Dichlorobenzene 95-50-1 N.D. 1. 5. ug/l 1

08202 EPA SW 846/8260 - Water

01587 Ethanol 64-17-5 N.D. 50. 250. ug/l 102010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 0.5 5. ug/l 102011 di-Isopropyl ether 108-20-3 N.D. 0.8 5. ug/l 102013 Ethyl t-butyl ether 637-92-3 N.D. 0.8 5. ug/l 102014 t-Amyl methyl ether 994-05-8 N.D. 0.8 5. ug/l 102015 t-Butyl alcohol 75-65-0 N.D. 10. 80. ug/l 106306 trans-1,3-Dichloropropene 10061-02-6 N.D. 1. 5. ug/l 106307 cis-1,3-Dichloropropene 10061-01-5 N.D. 1. 5. ug/l 108203 Freon 113 76-13-1 N.D. 2. 10. ug/l 1

State of Washington Lab Certification No. C259Trip blank vials were not received by the laboratory for this sample group.

All QC is compliant unless otherwise noted. Please refer to the QualityControl Summary for overall QC performance data and associated samples.

Laboratory ChronicleCAT Analysis DilutionNo. Analysis Name Method Trial# Date and Time Analyst Factor06035 Lead SW-846 6020 1 01/19/2008 18:58 David K Beck 102211 TPH by NWTPH-Dx(water)

w/SiGelECY 97-602 NWTPH-Dxmodified

1 01/15/2008 21:22 Matthew E Barton 1

08273 TPH by NWTPH-Gx waters ECY 97-602 NWTPH-Gxmodified

1 01/15/2008 04:07 Steven A Skiles 1

05382 EPA SW846/8260 (water) SW-846 8260B 1 01/15/2008 04:03 Kathrine K Muramatsu 108202 EPA SW 846/8260 - Water SW-846 8260B 1 01/15/2008 04:03 Kathrine K Muramatsu 101146 GC VOA Water Prep SW-846 5030B 1 01/15/2008 04:07 Steven A Skiles 101163 GC/MS VOA Water Prep SW-846 5030B 1 01/15/2008 04:03 Kathrine K Muramatsu 1

Page 3 of 3

Lancaster Laboratories Sample No. 5255498 WW Group No. 1073037

MW-5 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:10 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K05

*=This limit was used in the evaluation of the final result

02135 Extraction - DRO WaterSpecial

ECY 97-602 NWTPH-Dx06/97

1 01/15/2008 03:00 Sherry L Morrow 1

06050 ICP/MS SW-846 Water SW-846 3010A modified 1 01/17/2008 00:20 Helen L Schaeffer 1

Page 1 of 3

Lancaster Laboratories Sample No. 5255499 WW Group No. 1073037

MW-6 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:37 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K06

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

06035 Lead 7439-92-1 N.D. 0.047 1.0 ug/l 1

02211 TPH by NWTPH-Dx(water)w/SiGel

02095 Diesel Range Organics n.a. N.D. 76. 240. ug/l 102096 Heavy Range Organics n.a. N.D. 95. 470. ug/l 1

08273 TPH by NWTPH-Gx waters

01645 TPH by NWTPH-Gx waters n.a. N.D. 50. 250. ug/l 1

05382 EPA SW846/8260 (water)

05385 Chloromethane 74-87-3 N.D. 1. 5. ug/l 105386 Vinyl Chloride 75-01-4 N.D. 1. 5. ug/l 105387 Bromomethane 74-83-9 N.D. 1. 5. ug/l 105388 Chloroethane 75-00-3 N.D. 1. 5. ug/l 105389 Trichlorofluoromethane 75-69-4 N.D. 2. 5. ug/l 105390 1,1-Dichloroethene 75-35-4 N.D. 0.8 5. ug/l 105391 Methylene Chloride 75-09-2 N.D. 2. 5. ug/l 105392 trans-1,2-Dichloroethene 156-60-5 N.D. 0.8 5. ug/l 105393 1,1-Dichloroethane 75-34-3 N.D. 1. 5. ug/l 105395 cis-1,2-Dichloroethene 156-59-2 N.D. 0.8 5. ug/l 105396 Chloroform 67-66-3 N.D. 0.8 5. ug/l 105398 1,1,1-Trichloroethane 71-55-6 N.D. 0.8 5. ug/l 105399 Carbon Tetrachloride 56-23-5 N.D. 1. 5. ug/l 105401 Benzene 71-43-2 N.D. 0.5 5. ug/l 105402 1,2-Dichloroethane 107-06-2 N.D. 1. 5. ug/l 105403 Trichloroethene 79-01-6 N.D. 1. 5. ug/l 105404 1,2-Dichloropropane 78-87-5 N.D. 1. 5. ug/l 105406 Bromodichloromethane 75-27-4 N.D. 1. 5. ug/l 105407 Toluene 108-88-3 N.D. 0.7 5. ug/l 105408 1,1,2-Trichloroethane 79-00-5 N.D. 0.8 5. ug/l 105409 Tetrachloroethene 127-18-4 N.D. 0.8 5. ug/l 105411 Dibromochloromethane 124-48-1 N.D. 1. 5. ug/l 105413 Chlorobenzene 108-90-7 N.D. 0.8 5. ug/l 105415 Ethylbenzene 100-41-4 N.D. 0.8 5. ug/l 105416 m+p-Xylene 1330-20-7 N.D. 0.8 5. ug/l 105417 o-Xylene 95-47-6 N.D. 0.8 5. ug/l 1

Page 2 of 3

Lancaster Laboratories Sample No. 5255499 WW Group No. 1073037

MW-6 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:37 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K06

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

05419 Bromoform 75-25-2 N.D. 1. 5. ug/l 105421 1,1,2,2-Tetrachloroethane 79-34-5 N.D. 1. 5. ug/l 105432 1,3-Dichlorobenzene 541-73-1 N.D. 1. 5. ug/l 105433 1,4-Dichlorobenzene 106-46-7 N.D. 1. 5. ug/l 105435 1,2-Dichlorobenzene 95-50-1 N.D. 1. 5. ug/l 1

08202 EPA SW 846/8260 - Water

01587 Ethanol 64-17-5 N.D. 50. 250. ug/l 102010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 0.5 5. ug/l 102011 di-Isopropyl ether 108-20-3 N.D. 0.8 5. ug/l 102013 Ethyl t-butyl ether 637-92-3 N.D. 0.8 5. ug/l 102014 t-Amyl methyl ether 994-05-8 N.D. 0.8 5. ug/l 102015 t-Butyl alcohol 75-65-0 N.D. 10. 80. ug/l 106306 trans-1,3-Dichloropropene 10061-02-6 N.D. 1. 5. ug/l 106307 cis-1,3-Dichloropropene 10061-01-5 N.D. 1. 5. ug/l 108203 Freon 113 76-13-1 N.D. 2. 10. ug/l 1

State of Washington Lab Certification No. C259Trip blank vials were not received by the laboratory for this sample group.

All QC is compliant unless otherwise noted. Please refer to the QualityControl Summary for overall QC performance data and associated samples.

Laboratory ChronicleCAT Analysis DilutionNo. Analysis Name Method Trial# Date and Time Analyst Factor06035 Lead SW-846 6020 1 01/19/2008 19:01 David K Beck 102211 TPH by NWTPH-Dx(water)

w/SiGelECY 97-602 NWTPH-Dxmodified

1 01/15/2008 21:41 Matthew E Barton 1

08273 TPH by NWTPH-Gx waters ECY 97-602 NWTPH-Gxmodified

1 01/15/2008 04:36 Steven A Skiles 1

05382 EPA SW846/8260 (water) SW-846 8260B 1 01/15/2008 05:58 Kathrine K Muramatsu 108202 EPA SW 846/8260 - Water SW-846 8260B 1 01/15/2008 05:58 Kathrine K Muramatsu 101146 GC VOA Water Prep SW-846 5030B 1 01/15/2008 04:36 Steven A Skiles 101163 GC/MS VOA Water Prep SW-846 5030B 1 01/15/2008 05:58 Kathrine K Muramatsu 1

Page 3 of 3

Lancaster Laboratories Sample No. 5255499 WW Group No. 1073037

MW-6 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:37 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K06

*=This limit was used in the evaluation of the final result

02135 Extraction - DRO WaterSpecial

ECY 97-602 NWTPH-Dx06/97

1 01/15/2008 03:00 Sherry L Morrow 1

06050 ICP/MS SW-846 Water SW-846 3010A modified 1 01/17/2008 00:20 Helen L Schaeffer 1

Page 1 of 3

Lancaster Laboratories Sample No. 5255500 WW Group No. 1073037

MW-1 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:58 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K01

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

06035 Lead 7439-92-1 N.D. 0.047 1.0 ug/l 1

02211 TPH by NWTPH-Dx(water)w/SiGel

02095 Diesel Range Organics n.a. N.D. 76. 240. ug/l 102096 Heavy Range Organics n.a. N.D. 95. 470. ug/l 1

08273 TPH by NWTPH-Gx waters

01645 TPH by NWTPH-Gx waters n.a. 69. J 50. 250. ug/l 1

05382 EPA SW846/8260 (water)

05385 Chloromethane 74-87-3 N.D. 1. 5. ug/l 105386 Vinyl Chloride 75-01-4 N.D. 1. 5. ug/l 105387 Bromomethane 74-83-9 N.D. 1. 5. ug/l 105388 Chloroethane 75-00-3 N.D. 1. 5. ug/l 105389 Trichlorofluoromethane 75-69-4 N.D. 2. 5. ug/l 105390 1,1-Dichloroethene 75-35-4 N.D. 0.8 5. ug/l 105391 Methylene Chloride 75-09-2 N.D. 2. 5. ug/l 105392 trans-1,2-Dichloroethene 156-60-5 N.D. 0.8 5. ug/l 105393 1,1-Dichloroethane 75-34-3 N.D. 1. 5. ug/l 105395 cis-1,2-Dichloroethene 156-59-2 N.D. 0.8 5. ug/l 105396 Chloroform 67-66-3 N.D. 0.8 5. ug/l 105398 1,1,1-Trichloroethane 71-55-6 N.D. 0.8 5. ug/l 105399 Carbon Tetrachloride 56-23-5 N.D. 1. 5. ug/l 105401 Benzene 71-43-2 N.D. 0.5 5. ug/l 105402 1,2-Dichloroethane 107-06-2 N.D. 1. 5. ug/l 105403 Trichloroethene 79-01-6 N.D. 1. 5. ug/l 105404 1,2-Dichloropropane 78-87-5 N.D. 1. 5. ug/l 105406 Bromodichloromethane 75-27-4 N.D. 1. 5. ug/l 105407 Toluene 108-88-3 N.D. 0.7 5. ug/l 105408 1,1,2-Trichloroethane 79-00-5 N.D. 0.8 5. ug/l 105409 Tetrachloroethene 127-18-4 N.D. 0.8 5. ug/l 105411 Dibromochloromethane 124-48-1 N.D. 1. 5. ug/l 105413 Chlorobenzene 108-90-7 N.D. 0.8 5. ug/l 105415 Ethylbenzene 100-41-4 N.D. 0.8 5. ug/l 105416 m+p-Xylene 1330-20-7 N.D. 0.8 5. ug/l 105417 o-Xylene 95-47-6 N.D. 0.8 5. ug/l 1

Page 2 of 3

Lancaster Laboratories Sample No. 5255500 WW Group No. 1073037

MW-1 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:58 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K01

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

05419 Bromoform 75-25-2 N.D. 1. 5. ug/l 105421 1,1,2,2-Tetrachloroethane 79-34-5 N.D. 1. 5. ug/l 105432 1,3-Dichlorobenzene 541-73-1 N.D. 1. 5. ug/l 105433 1,4-Dichlorobenzene 106-46-7 N.D. 1. 5. ug/l 105435 1,2-Dichlorobenzene 95-50-1 N.D. 1. 5. ug/l 1

08202 EPA SW 846/8260 - Water

01587 Ethanol 64-17-5 N.D. 50. 250. ug/l 102010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 0.5 5. ug/l 102011 di-Isopropyl ether 108-20-3 N.D. 0.8 5. ug/l 102013 Ethyl t-butyl ether 637-92-3 N.D. 0.8 5. ug/l 102014 t-Amyl methyl ether 994-05-8 N.D. 0.8 5. ug/l 102015 t-Butyl alcohol 75-65-0 N.D. 10. 80. ug/l 106306 trans-1,3-Dichloropropene 10061-02-6 N.D. 1. 5. ug/l 106307 cis-1,3-Dichloropropene 10061-01-5 N.D. 1. 5. ug/l 108203 Freon 113 76-13-1 N.D. 2. 10. ug/l 1

State of Washington Lab Certification No. C259Trip blank vials were not received by the laboratory for this sample group.

All QC is compliant unless otherwise noted. Please refer to the QualityControl Summary for overall QC performance data and associated samples.

Laboratory ChronicleCAT Analysis DilutionNo. Analysis Name Method Trial# Date and Time Analyst Factor06035 Lead SW-846 6020 1 01/19/2008 19:08 David K Beck 102211 TPH by NWTPH-Dx(water)

w/SiGelECY 97-602 NWTPH-Dxmodified

1 01/15/2008 22:01 Matthew E Barton 1

08273 TPH by NWTPH-Gx waters ECY 97-602 NWTPH-Gxmodified

1 01/15/2008 05:05 Steven A Skiles 1

05382 EPA SW846/8260 (water) SW-846 8260B 1 01/15/2008 06:20 Kathrine K Muramatsu 108202 EPA SW 846/8260 - Water SW-846 8260B 1 01/15/2008 06:20 Kathrine K Muramatsu 101146 GC VOA Water Prep SW-846 5030B 1 01/15/2008 05:05 Steven A Skiles 101163 GC/MS VOA Water Prep SW-846 5030B 1 01/15/2008 06:20 Kathrine K Muramatsu 1

Page 3 of 3

Lancaster Laboratories Sample No. 5255500 WW Group No. 1073037

MW-1 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 09:58 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K01

*=This limit was used in the evaluation of the final result

02135 Extraction - DRO WaterSpecial

ECY 97-602 NWTPH-Dx06/97

1 01/15/2008 03:00 Sherry L Morrow 1

06050 ICP/MS SW-846 Water SW-846 3010A modified 1 01/17/2008 00:20 Helen L Schaeffer 1

Page 1 of 3

Lancaster Laboratories Sample No. 5255501 WW Group No. 1073037

TW-1 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 10:26 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68KT1

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

06035 Lead 7439-92-1 1.5 0.047 1.0 ug/l 1

02211 TPH by NWTPH-Dx(water)w/SiGel

02095 Diesel Range Organics n.a. 370. J 150. 470. ug/l 202096 Heavy Range Organics n.a. N.D. 190. 940. ug/l 2

Due to the nature of the sample extract matrix, a dilution was used forthe analysis. The reporting limits were raised accordingly.

08273 TPH by NWTPH-Gx waters

01645 TPH by NWTPH-Gx waters n.a. 2,200. 50. 250. ug/l 1An elevated surrogate recovery was observed. The analysis was not repeated dueto limited sample volume.

05382 EPA SW846/8260 (water)

05385 Chloromethane 74-87-3 N.D. 1. 5. ug/l 105386 Vinyl Chloride 75-01-4 N.D. 1. 5. ug/l 105387 Bromomethane 74-83-9 N.D. 1. 5. ug/l 105388 Chloroethane 75-00-3 N.D. 1. 5. ug/l 105389 Trichlorofluoromethane 75-69-4 N.D. 2. 5. ug/l 105390 1,1-Dichloroethene 75-35-4 N.D. 0.8 5. ug/l 105391 Methylene Chloride 75-09-2 N.D. 2. 5. ug/l 105392 trans-1,2-Dichloroethene 156-60-5 N.D. 0.8 5. ug/l 105393 1,1-Dichloroethane 75-34-3 N.D. 1. 5. ug/l 105395 cis-1,2-Dichloroethene 156-59-2 N.D. 0.8 5. ug/l 105396 Chloroform 67-66-3 N.D. 0.8 5. ug/l 105398 1,1,1-Trichloroethane 71-55-6 N.D. 0.8 5. ug/l 105399 Carbon Tetrachloride 56-23-5 N.D. 1. 5. ug/l 105401 Benzene 71-43-2 150. 0.5 5. ug/l 105402 1,2-Dichloroethane 107-06-2 N.D. 1. 5. ug/l 105403 Trichloroethene 79-01-6 N.D. 1. 5. ug/l 105404 1,2-Dichloropropane 78-87-5 N.D. 1. 5. ug/l 105406 Bromodichloromethane 75-27-4 N.D. 1. 5. ug/l 105407 Toluene 108-88-3 17. 0.7 5. ug/l 105408 1,1,2-Trichloroethane 79-00-5 N.D. 0.8 5. ug/l 105409 Tetrachloroethene 127-18-4 N.D. 0.8 5. ug/l 105411 Dibromochloromethane 124-48-1 N.D. 1. 5. ug/l 1

Page 2 of 3

Lancaster Laboratories Sample No. 5255501 WW Group No. 1073037

TW-1 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 10:26 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68KT1

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

05413 Chlorobenzene 108-90-7 1. J 0.8 5. ug/l 105415 Ethylbenzene 100-41-4 87. 0.8 5. ug/l 105416 m+p-Xylene 1330-20-7 190. 0.8 5. ug/l 105417 o-Xylene 95-47-6 5. 0.8 5. ug/l 105419 Bromoform 75-25-2 N.D. 1. 5. ug/l 105421 1,1,2,2-Tetrachloroethane 79-34-5 N.D. 1. 5. ug/l 105432 1,3-Dichlorobenzene 541-73-1 N.D. 1. 5. ug/l 105433 1,4-Dichlorobenzene 106-46-7 2. J 1. 5. ug/l 105435 1,2-Dichlorobenzene 95-50-1 N.D. 1. 5. ug/l 1

08202 EPA SW 846/8260 - Water

01587 Ethanol 64-17-5 N.D. 50. 250. ug/l 102010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 0.5 5. ug/l 102011 di-Isopropyl ether 108-20-3 N.D. 0.8 5. ug/l 102013 Ethyl t-butyl ether 637-92-3 N.D. 0.8 5. ug/l 102014 t-Amyl methyl ether 994-05-8 N.D. 0.8 5. ug/l 102015 t-Butyl alcohol 75-65-0 N.D. 10. 80. ug/l 106306 trans-1,3-Dichloropropene 10061-02-6 N.D. 1. 5. ug/l 106307 cis-1,3-Dichloropropene 10061-01-5 N.D. 1. 5. ug/l 108203 Freon 113 76-13-1 N.D. 2. 10. ug/l 1

State of Washington Lab Certification No. C259Trip blank vials were not received by the laboratory for this sample group.

All QC is compliant unless otherwise noted. Please refer to the QualityControl Summary for overall QC performance data and associated samples.

Laboratory ChronicleCAT Analysis DilutionNo. Analysis Name Method Trial# Date and Time Analyst Factor06035 Lead SW-846 6020 1 01/19/2008 19:10 David K Beck 102211 TPH by NWTPH-Dx(water)

w/SiGelECY 97-602 NWTPH-Dxmodified

1 01/16/2008 13:00 Matthew E Barton 2

08273 TPH by NWTPH-Gx waters ECY 97-602 NWTPH-Gxmodified

1 01/15/2008 05:35 Steven A Skiles 1

Page 3 of 3

Lancaster Laboratories Sample No. 5255501 WW Group No. 1073037

TW-1 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 10:26 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68KT1

*=This limit was used in the evaluation of the final result

05382 EPA SW846/8260 (water) SW-846 8260B 1 01/15/2008 06:43 Kathrine K Muramatsu 108202 EPA SW 846/8260 - Water SW-846 8260B 1 01/15/2008 06:43 Kathrine K Muramatsu 101146 GC VOA Water Prep SW-846 5030B 1 01/15/2008 05:35 Steven A Skiles 101163 GC/MS VOA Water Prep SW-846 5030B 1 01/15/2008 06:43 Kathrine K Muramatsu 102135 Extraction - DRO Water

SpecialECY 97-602 NWTPH-Dx06/97

1 01/15/2008 03:00 Sherry L Morrow 1

06050 ICP/MS SW-846 Water SW-846 3010A modified 1 01/17/2008 00:20 Helen L Schaeffer 1

Page 1 of 3

Lancaster Laboratories Sample No. 5255502 WW Group No. 1073037

MW-7 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 11:17 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K07

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

06035 Lead 7439-92-1 N.D. 0.047 1.0 ug/l 1

02211 TPH by NWTPH-Dx(water)w/SiGel

02095 Diesel Range Organics n.a. N.D. 75. 240. ug/l 102096 Heavy Range Organics n.a. N.D. 94. 470. ug/l 1

08273 TPH by NWTPH-Gx waters

01645 TPH by NWTPH-Gx waters n.a. N.D. 50. 250. ug/l 1

05382 EPA SW846/8260 (water)

05385 Chloromethane 74-87-3 N.D. 1. 5. ug/l 105386 Vinyl Chloride 75-01-4 N.D. 1. 5. ug/l 105387 Bromomethane 74-83-9 N.D. 1. 5. ug/l 105388 Chloroethane 75-00-3 N.D. 1. 5. ug/l 105389 Trichlorofluoromethane 75-69-4 N.D. 2. 5. ug/l 105390 1,1-Dichloroethene 75-35-4 N.D. 0.8 5. ug/l 105391 Methylene Chloride 75-09-2 N.D. 2. 5. ug/l 105392 trans-1,2-Dichloroethene 156-60-5 N.D. 0.8 5. ug/l 105393 1,1-Dichloroethane 75-34-3 N.D. 1. 5. ug/l 105395 cis-1,2-Dichloroethene 156-59-2 N.D. 0.8 5. ug/l 105396 Chloroform 67-66-3 N.D. 0.8 5. ug/l 105398 1,1,1-Trichloroethane 71-55-6 N.D. 0.8 5. ug/l 105399 Carbon Tetrachloride 56-23-5 N.D. 1. 5. ug/l 105401 Benzene 71-43-2 N.D. 0.5 5. ug/l 105402 1,2-Dichloroethane 107-06-2 N.D. 1. 5. ug/l 105403 Trichloroethene 79-01-6 N.D. 1. 5. ug/l 105404 1,2-Dichloropropane 78-87-5 N.D. 1. 5. ug/l 105406 Bromodichloromethane 75-27-4 N.D. 1. 5. ug/l 105407 Toluene 108-88-3 N.D. 0.7 5. ug/l 105408 1,1,2-Trichloroethane 79-00-5 N.D. 0.8 5. ug/l 105409 Tetrachloroethene 127-18-4 N.D. 0.8 5. ug/l 105411 Dibromochloromethane 124-48-1 N.D. 1. 5. ug/l 105413 Chlorobenzene 108-90-7 N.D. 0.8 5. ug/l 105415 Ethylbenzene 100-41-4 N.D. 0.8 5. ug/l 105416 m+p-Xylene 1330-20-7 N.D. 0.8 5. ug/l 105417 o-Xylene 95-47-6 N.D. 0.8 5. ug/l 1

Page 2 of 3

Lancaster Laboratories Sample No. 5255502 WW Group No. 1073037

MW-7 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 11:17 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K07

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

05419 Bromoform 75-25-2 N.D. 1. 5. ug/l 105421 1,1,2,2-Tetrachloroethane 79-34-5 N.D. 1. 5. ug/l 105432 1,3-Dichlorobenzene 541-73-1 N.D. 1. 5. ug/l 105433 1,4-Dichlorobenzene 106-46-7 N.D. 1. 5. ug/l 105435 1,2-Dichlorobenzene 95-50-1 N.D. 1. 5. ug/l 1

08202 EPA SW 846/8260 - Water

01587 Ethanol 64-17-5 N.D. 50. 250. ug/l 102010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 0.5 5. ug/l 102011 di-Isopropyl ether 108-20-3 N.D. 0.8 5. ug/l 102013 Ethyl t-butyl ether 637-92-3 N.D. 0.8 5. ug/l 102014 t-Amyl methyl ether 994-05-8 N.D. 0.8 5. ug/l 102015 t-Butyl alcohol 75-65-0 N.D. 10. 80. ug/l 106306 trans-1,3-Dichloropropene 10061-02-6 N.D. 1. 5. ug/l 106307 cis-1,3-Dichloropropene 10061-01-5 N.D. 1. 5. ug/l 108203 Freon 113 76-13-1 N.D. 2. 10. ug/l 1

State of Washington Lab Certification No. C259Trip blank vials were not received by the laboratory for this sample group.

All QC is compliant unless otherwise noted. Please refer to the QualityControl Summary for overall QC performance data and associated samples.

Laboratory ChronicleCAT Analysis DilutionNo. Analysis Name Method Trial# Date and Time Analyst Factor06035 Lead SW-846 6020 1 01/19/2008 19:13 David K Beck 102211 TPH by NWTPH-Dx(water)

w/SiGelECY 97-602 NWTPH-Dxmodified

1 01/15/2008 22:20 Matthew E Barton 1

08273 TPH by NWTPH-Gx waters ECY 97-602 NWTPH-Gxmodified

1 01/15/2008 06:04 Steven A Skiles 1

05382 EPA SW846/8260 (water) SW-846 8260B 1 01/15/2008 07:06 Kathrine K Muramatsu 108202 EPA SW 846/8260 - Water SW-846 8260B 1 01/15/2008 07:06 Kathrine K Muramatsu 101146 GC VOA Water Prep SW-846 5030B 1 01/15/2008 06:04 Steven A Skiles 101163 GC/MS VOA Water Prep SW-846 5030B 1 01/15/2008 07:06 Kathrine K Muramatsu 1

Page 3 of 3

Lancaster Laboratories Sample No. 5255502 WW Group No. 1073037

MW-7 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 11:17 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K07

*=This limit was used in the evaluation of the final result

02135 Extraction - DRO WaterSpecial

ECY 97-602 NWTPH-Dx06/97

1 01/15/2008 03:00 Sherry L Morrow 1

06050 ICP/MS SW-846 Water SW-846 3010A modified 1 01/17/2008 00:20 Helen L Schaeffer 1

Page 1 of 3

Lancaster Laboratories Sample No. 5255503 WW Group No. 1073037

TW-3 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 12:00 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68KT3

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

06035 Lead 7439-92-1 1.7 0.047 1.0 ug/l 1

02211 TPH by NWTPH-Dx(water)w/SiGel

02095 Diesel Range Organics n.a. N.D. 77. 240. ug/l 102096 Heavy Range Organics n.a. N.D. 96. 480. ug/l 1

08273 TPH by NWTPH-Gx waters

01645 TPH by NWTPH-Gx waters n.a. N.D. 50. 250. ug/l 1

05382 EPA SW846/8260 (water)

05385 Chloromethane 74-87-3 N.D. 1. 5. ug/l 105386 Vinyl Chloride 75-01-4 N.D. 1. 5. ug/l 105387 Bromomethane 74-83-9 N.D. 1. 5. ug/l 105388 Chloroethane 75-00-3 N.D. 1. 5. ug/l 105389 Trichlorofluoromethane 75-69-4 N.D. 2. 5. ug/l 105390 1,1-Dichloroethene 75-35-4 N.D. 0.8 5. ug/l 105391 Methylene Chloride 75-09-2 N.D. 2. 5. ug/l 105392 trans-1,2-Dichloroethene 156-60-5 N.D. 0.8 5. ug/l 105393 1,1-Dichloroethane 75-34-3 N.D. 1. 5. ug/l 105395 cis-1,2-Dichloroethene 156-59-2 N.D. 0.8 5. ug/l 105396 Chloroform 67-66-3 N.D. 0.8 5. ug/l 105398 1,1,1-Trichloroethane 71-55-6 N.D. 0.8 5. ug/l 105399 Carbon Tetrachloride 56-23-5 N.D. 1. 5. ug/l 105401 Benzene 71-43-2 N.D. 0.5 5. ug/l 105402 1,2-Dichloroethane 107-06-2 N.D. 1. 5. ug/l 105403 Trichloroethene 79-01-6 N.D. 1. 5. ug/l 105404 1,2-Dichloropropane 78-87-5 N.D. 1. 5. ug/l 105406 Bromodichloromethane 75-27-4 N.D. 1. 5. ug/l 105407 Toluene 108-88-3 N.D. 0.7 5. ug/l 105408 1,1,2-Trichloroethane 79-00-5 N.D. 0.8 5. ug/l 105409 Tetrachloroethene 127-18-4 N.D. 0.8 5. ug/l 105411 Dibromochloromethane 124-48-1 N.D. 1. 5. ug/l 105413 Chlorobenzene 108-90-7 N.D. 0.8 5. ug/l 105415 Ethylbenzene 100-41-4 N.D. 0.8 5. ug/l 105416 m+p-Xylene 1330-20-7 N.D. 0.8 5. ug/l 105417 o-Xylene 95-47-6 N.D. 0.8 5. ug/l 1

Page 2 of 3

Lancaster Laboratories Sample No. 5255503 WW Group No. 1073037

TW-3 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 12:00 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68KT3

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

05419 Bromoform 75-25-2 N.D. 1. 5. ug/l 105421 1,1,2,2-Tetrachloroethane 79-34-5 N.D. 1. 5. ug/l 105432 1,3-Dichlorobenzene 541-73-1 N.D. 1. 5. ug/l 105433 1,4-Dichlorobenzene 106-46-7 N.D. 1. 5. ug/l 105435 1,2-Dichlorobenzene 95-50-1 N.D. 1. 5. ug/l 1

08202 EPA SW 846/8260 - Water

01587 Ethanol 64-17-5 N.D. 50. 250. ug/l 102010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 0.5 5. ug/l 102011 di-Isopropyl ether 108-20-3 N.D. 0.8 5. ug/l 102013 Ethyl t-butyl ether 637-92-3 N.D. 0.8 5. ug/l 102014 t-Amyl methyl ether 994-05-8 N.D. 0.8 5. ug/l 102015 t-Butyl alcohol 75-65-0 N.D. 10. 80. ug/l 106306 trans-1,3-Dichloropropene 10061-02-6 N.D. 1. 5. ug/l 106307 cis-1,3-Dichloropropene 10061-01-5 N.D. 1. 5. ug/l 108203 Freon 113 76-13-1 N.D. 2. 10. ug/l 1

State of Washington Lab Certification No. C259Trip blank vials were not received by the laboratory for this sample group.

All QC is compliant unless otherwise noted. Please refer to the QualityControl Summary for overall QC performance data and associated samples.

Laboratory ChronicleCAT Analysis DilutionNo. Analysis Name Method Trial# Date and Time Analyst Factor06035 Lead SW-846 6020 1 01/19/2008 19:15 David K Beck 102211 TPH by NWTPH-Dx(water)

w/SiGelECY 97-602 NWTPH-Dxmodified

1 01/16/2008 01:36 Matthew E Barton 1

08273 TPH by NWTPH-Gx waters ECY 97-602 NWTPH-Gxmodified

1 01/15/2008 06:34 Steven A Skiles 1

05382 EPA SW846/8260 (water) SW-846 8260B 1 01/16/2008 16:01 Matthew F Regan 108202 EPA SW 846/8260 - Water SW-846 8260B 1 01/16/2008 16:01 Matthew F Regan 101146 GC VOA Water Prep SW-846 5030B 1 01/15/2008 06:34 Steven A Skiles 101163 GC/MS VOA Water Prep SW-846 5030B 1 01/16/2008 16:01 Matthew F Regan 1

Page 3 of 3

Lancaster Laboratories Sample No. 5255503 WW Group No. 1073037

TW-3 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 12:00 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:48 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68KT3

*=This limit was used in the evaluation of the final result

02135 Extraction - DRO WaterSpecial

ECY 97-602 NWTPH-Dx06/97

1 01/15/2008 03:00 Sherry L Morrow 1

06050 ICP/MS SW-846 Water SW-846 3010A modified 1 01/17/2008 00:20 Helen L Schaeffer 1

Page 1 of 3

Lancaster Laboratories Sample No. 5255504 WW Group No. 1073037

MW-4 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 12:25 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:49 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K04

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

06035 Lead 7439-92-1 0.29 J 0.047 1.0 ug/l 1

02211 TPH by NWTPH-Dx(water)w/SiGel

02095 Diesel Range Organics n.a. 230. J 76. 240. ug/l 102096 Heavy Range Organics n.a. N.D. 94. 470. ug/l 1

08273 TPH by NWTPH-Gx waters

01645 TPH by NWTPH-Gx waters n.a. 88. J 50. 250. ug/l 1

05382 EPA SW846/8260 (water)

05385 Chloromethane 74-87-3 N.D. 1. 5. ug/l 105386 Vinyl Chloride 75-01-4 N.D. 1. 5. ug/l 105387 Bromomethane 74-83-9 N.D. 1. 5. ug/l 105388 Chloroethane 75-00-3 N.D. 1. 5. ug/l 105389 Trichlorofluoromethane 75-69-4 N.D. 2. 5. ug/l 105390 1,1-Dichloroethene 75-35-4 N.D. 0.8 5. ug/l 105391 Methylene Chloride 75-09-2 N.D. 2. 5. ug/l 105392 trans-1,2-Dichloroethene 156-60-5 N.D. 0.8 5. ug/l 105393 1,1-Dichloroethane 75-34-3 N.D. 1. 5. ug/l 105395 cis-1,2-Dichloroethene 156-59-2 N.D. 0.8 5. ug/l 105396 Chloroform 67-66-3 N.D. 0.8 5. ug/l 105398 1,1,1-Trichloroethane 71-55-6 N.D. 0.8 5. ug/l 105399 Carbon Tetrachloride 56-23-5 N.D. 1. 5. ug/l 105401 Benzene 71-43-2 N.D. 0.5 5. ug/l 105402 1,2-Dichloroethane 107-06-2 N.D. 1. 5. ug/l 105403 Trichloroethene 79-01-6 N.D. 1. 5. ug/l 105404 1,2-Dichloropropane 78-87-5 N.D. 1. 5. ug/l 105406 Bromodichloromethane 75-27-4 N.D. 1. 5. ug/l 105407 Toluene 108-88-3 N.D. 0.7 5. ug/l 105408 1,1,2-Trichloroethane 79-00-5 N.D. 0.8 5. ug/l 105409 Tetrachloroethene 127-18-4 N.D. 0.8 5. ug/l 105411 Dibromochloromethane 124-48-1 N.D. 1. 5. ug/l 105413 Chlorobenzene 108-90-7 N.D. 0.8 5. ug/l 105415 Ethylbenzene 100-41-4 N.D. 0.8 5. ug/l 105416 m+p-Xylene 1330-20-7 N.D. 0.8 5. ug/l 105417 o-Xylene 95-47-6 N.D. 0.8 5. ug/l 1

Page 2 of 3

Lancaster Laboratories Sample No. 5255504 WW Group No. 1073037

MW-4 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 12:25 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:49 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K04

*=This limit was used in the evaluation of the final result

As Received As Received

CAT As Received Method Limit of Dilution

No. Analysis Name CAS Number Result DetectionLimit*

Quantitation Units Factor

05419 Bromoform 75-25-2 N.D. 1. 5. ug/l 105421 1,1,2,2-Tetrachloroethane 79-34-5 N.D. 1. 5. ug/l 105432 1,3-Dichlorobenzene 541-73-1 N.D. 1. 5. ug/l 105433 1,4-Dichlorobenzene 106-46-7 N.D. 1. 5. ug/l 105435 1,2-Dichlorobenzene 95-50-1 N.D. 1. 5. ug/l 1

08202 EPA SW 846/8260 - Water

01587 Ethanol 64-17-5 N.D. 50. 250. ug/l 102010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 0.5 5. ug/l 102011 di-Isopropyl ether 108-20-3 N.D. 0.8 5. ug/l 102013 Ethyl t-butyl ether 637-92-3 N.D. 0.8 5. ug/l 102014 t-Amyl methyl ether 994-05-8 N.D. 0.8 5. ug/l 102015 t-Butyl alcohol 75-65-0 13. J 10. 80. ug/l 106306 trans-1,3-Dichloropropene 10061-02-6 N.D. 1. 5. ug/l 106307 cis-1,3-Dichloropropene 10061-01-5 N.D. 1. 5. ug/l 108203 Freon 113 76-13-1 N.D. 2. 10. ug/l 1

State of Washington Lab Certification No. C259Trip blank vials were not received by the laboratory for this sample group.

All QC is compliant unless otherwise noted. Please refer to the QualityControl Summary for overall QC performance data and associated samples.

Laboratory ChronicleCAT Analysis DilutionNo. Analysis Name Method Trial# Date and Time Analyst Factor06035 Lead SW-846 6020 1 01/19/2008 19:17 David K Beck 102211 TPH by NWTPH-Dx(water)

w/SiGelECY 97-602 NWTPH-Dxmodified

1 01/16/2008 01:55 Matthew E Barton 1

08273 TPH by NWTPH-Gx waters ECY 97-602 NWTPH-Gxmodified

1 01/15/2008 08:32 Steven A Skiles 1

05382 EPA SW846/8260 (water) SW-846 8260B 1 01/16/2008 16:47 Matthew F Regan 108202 EPA SW 846/8260 - Water SW-846 8260B 1 01/16/2008 16:47 Matthew F Regan 101146 GC VOA Water Prep SW-846 5030B 1 01/15/2008 08:32 Steven A Skiles 101163 GC/MS VOA Water Prep SW-846 5030B 1 01/16/2008 16:47 Matthew F Regan 1

Page 3 of 3

Lancaster Laboratories Sample No. 5255504 WW Group No. 1073037

MW-4 Grab WaterSite# 270549221208 68th - Kent, WA

Collected:01/09/2008 12:25 by FL Account Number: 12258

Submitted: 01/12/2008 10:20 ConocoPhillipsReported: 01/23/2008 at 08:49 Suite 212Discard: 02/23/2008 1230 W. Washington

Tempe AZ 85281 68K04

*=This limit was used in the evaluation of the final result

02135 Extraction - DRO WaterSpecial

ECY 97-602 NWTPH-Dx06/97

1 01/15/2008 03:00 Sherry L Morrow 1

06050 ICP/MS SW-846 Water SW-846 3010A modified 1 01/17/2008 00:20 Helen L Schaeffer 1

Page 1 of 6

Quality Control Summary

Client Name: ConocoPhillips Group Number: 1073037Reported: 01/23/08 at 08:49 AM

*- Outside of specification**-This limit was used in the evaluation of the final result for the blank(1) The result for one or both determinations was less than five times the LOQ.(2) The unspiked result was more than four times the spike added.

Matrix QC may not be reported if site-specific QC samples were notsubmitted. In these situations, to demonstrate precision and accuracy ata batch level, a LCS/LCSD was performed, unless otherwise specified in themethod.

Laboratory Compliance Quality Control

Blank Blank Blank Report LCS LCSD LCS/LCSDAnalysis Name Result MDL** LOQ Units %REC %REC Limits RPD RPD Max

Batch number: 080140011A Sample number(s): 5255498-5255502Diesel Range Organics N.D. 80. 250. ug/l 73 80 61-106 10 20Heavy Range Organics N.D. 100. 500. ug/l

Batch number: 080140012A Sample number(s): 5255503-5255504Diesel Range Organics N.D. 80. 250. ug/l 76 81 61-106 6 20Heavy Range Organics N.D. 100. 500. ug/l

Batch number: 08014A07A Sample number(s): 5255498-5255504TPH by NWTPH-Gx waters N.D. 50. 250. ug/l 99 101 75-135 2 30

Batch number: 080166050002A Sample number(s): 5255498-5255504Lead N.D. 0.047 1.0 ug/l 105 90-115

Batch number: N080142AA Sample number(s): 5255498-5255502Ethanol N.D. 50. 250. ug/l 108 107 31-166 0 30Methyl Tertiary Butyl Ether N.D. 0.5 5. ug/l 99 99 73-119 0 30di-Isopropyl ether N.D. 0.8 5. ug/l 106 107 70-123 1 30Ethyl t-butyl ether N.D. 0.8 5. ug/l 105 104 74-120 0 30t-Amyl methyl ether N.D. 0.8 5. ug/l 101 101 79-113 1 30t-Butyl alcohol N.D. 10. 80. ug/l 104 105 74-117 1 30Chloromethane N.D. 1. 5. ug/l 107 108 47-122 1 30Vinyl Chloride N.D. 1. 5. ug/l 112 112 54-123 0 30Bromomethane N.D. 1. 5. ug/l 97 98 49-117 2 30Chloroethane N.D. 1. 5. ug/l 101 100 54-117 1 30Trichlorofluoromethane N.D. 2. 5. ug/l 113 114 59-128 1 301,1-Dichloroethene N.D. 0.8 5. ug/l 101 102 76-122 1 30Methylene Chloride N.D. 2. 5. ug/l 98 99 85-120 1 30trans-1,2-Dichloroethene N.D. 0.8 5. ug/l 96 98 83-117 2 301,1-Dichloroethane N.D. 1. 5. ug/l 106 105 83-127 0 30cis-1,2-Dichloroethene N.D. 0.8 5. ug/l 97 97 84-117 1 30Chloroform N.D. 0.8 5. ug/l 105 103 77-125 1 301,1,1-Trichloroethane N.D. 0.8 5. ug/l 103 104 83-127 1 30Carbon Tetrachloride N.D. 1. 5. ug/l 102 102 77-130 0 30Benzene N.D. 0.5 5. ug/l 104 103 78-119 1 301,2-Dichloroethane N.D. 1. 5. ug/l 113 113 69-135 1 30Trichloroethene N.D. 1. 5. ug/l 100 100 87-117 1 301,2-Dichloropropane N.D. 1. 5. ug/l 104 105 80-117 1 30Bromodichloromethane N.D. 1. 5. ug/l 104 103 83-121 1 30Toluene N.D. 0.7 5. ug/l 100 100 85-115 0 301,1,2-Trichloroethane N.D. 0.8 5. ug/l 97 98 86-113 0 30Tetrachloroethene N.D. 0.8 5. ug/l 95 97 76-118 2 30Dibromochloromethane N.D. 1. 5. ug/l 100 102 78-119 2 30Chlorobenzene N.D. 0.8 5. ug/l 101 100 85-115 1 30Ethylbenzene N.D. 0.8 5. ug/l 103 102 82-119 1 30m+p-Xylene N.D. 0.8 5. ug/l 100 100 83-113 0 30o-Xylene N.D. 0.8 5. ug/l 100 100 83-113 0 30

Page 2 of 6

Quality Control Summary

Client Name: ConocoPhillips Group Number: 1073037Reported: 01/23/08 at 08:49 AM

*- Outside of specification**-This limit was used in the evaluation of the final result for the blank(1) The result for one or both determinations was less than five times the LOQ.(2) The unspiked result was more than four times the spike added.

Laboratory Compliance Quality Control

Blank Blank Blank Report LCS LCSD LCS/LCSDAnalysis Name Result MDL** LOQ Units %REC %REC Limits RPD RPD MaxBromoform N.D. 1. 5. ug/l 88 89 69-118 0 301,1,2,2-Tetrachloroethane N.D. 1. 5. ug/l 97 97 72-119 1 301,3-Dichlorobenzene N.D. 1. 5. ug/l 99 100 81-114 0 301,4-Dichlorobenzene N.D. 1. 5. ug/l 99 99 84-116 0 301,2-Dichlorobenzene N.D. 1. 5. ug/l 98 99 81-112 1 30trans-1,3-Dichloropropene N.D. 1. 5. ug/l 98 99 79-114 1 30cis-1,3-Dichloropropene N.D. 1. 5. ug/l 100 99 78-114 1 30Freon 113 N.D. 2. 10. ug/l 108 110 66-125 1 30

Batch number: N080161AA Sample number(s): 5255503-5255504Ethanol N.D. 50. 250. ug/l 117 119 31-166 2 30Methyl Tertiary Butyl Ether N.D. 0.5 5. ug/l 98 97 73-119 1 30di-Isopropyl ether N.D. 0.8 5. ug/l 109 108 70-123 0 30Ethyl t-butyl ether N.D. 0.8 5. ug/l 104 104 74-120 0 30t-Amyl methyl ether N.D. 0.8 5. ug/l 100 100 79-113 1 30t-Butyl alcohol N.D. 10. 80. ug/l 97 101 74-117 4 30Chloromethane N.D. 1. 5. ug/l 118 114 47-122 3 30Vinyl Chloride N.D. 1. 5. ug/l 120 117 54-123 2 30Bromomethane N.D. 1. 5. ug/l 100 98 49-117 2 30Chloroethane N.D. 1. 5. ug/l 106 105 54-117 1 30Trichlorofluoromethane N.D. 2. 5. ug/l 109 107 59-128 2 301,1-Dichloroethene N.D. 0.8 5. ug/l 101 100 76-122 1 30Methylene Chloride N.D. 2. 5. ug/l 99 99 85-120 1 30trans-1,2-Dichloroethene N.D. 0.8 5. ug/l 99 98 83-117 1 301,1-Dichloroethane N.D. 1. 5. ug/l 107 107 83-127 0 30cis-1,2-Dichloroethene N.D. 0.8 5. ug/l 96 96 84-117 1 30Chloroform N.D. 0.8 5. ug/l 106 105 77-125 0 301,1,1-Trichloroethane N.D. 0.8 5. ug/l 103 102 83-127 1 30Carbon Tetrachloride N.D. 1. 5. ug/l 101 99 77-130 2 30Benzene N.D. 0.5 5. ug/l 104 103 78-119 1 301,2-Dichloroethane N.D. 1. 5. ug/l 114 112 69-135 2 30Trichloroethene N.D. 1. 5. ug/l 101 99 87-117 2 301,2-Dichloropropane N.D. 1. 5. ug/l 105 104 80-117 1 30Bromodichloromethane N.D. 1. 5. ug/l 102 102 83-121 0 30Toluene N.D. 0.7 5. ug/l 99 98 85-115 1 301,1,2-Trichloroethane N.D. 0.8 5. ug/l 94 93 86-113 1 30Tetrachloroethene N.D. 0.8 5. ug/l 93 93 76-118 1 30Dibromochloromethane N.D. 1. 5. ug/l 95 96 78-119 0 30Chlorobenzene N.D. 0.8 5. ug/l 98 98 85-115 1 30Ethylbenzene N.D. 0.8 5. ug/l 102 101 82-119 1 30m+p-Xylene N.D. 0.8 5. ug/l 98 97 83-113 0 30o-Xylene N.D. 0.8 5. ug/l 97 97 83-113 0 30Bromoform N.D. 1. 5. ug/l 82 82 69-118 0 301,1,2,2-Tetrachloroethane N.D. 1. 5. ug/l 94 94 72-119 0 301,3-Dichlorobenzene N.D. 1. 5. ug/l 95 94 81-114 1 301,4-Dichlorobenzene N.D. 1. 5. ug/l 95 94 84-116 1 301,2-Dichlorobenzene N.D. 1. 5. ug/l 95 94 81-112 1 30trans-1,3-Dichloropropene N.D. 1. 5. ug/l 96 96 79-114 0 30cis-1,3-Dichloropropene N.D. 1. 5. ug/l 99 99 78-114 0 30Freon 113 N.D. 2. 10. ug/l 98 96 66-125 2 30

Sample Matrix Quality Control

Page 3 of 6

Quality Control Summary

Client Name: ConocoPhillips Group Number: 1073037Reported: 01/23/08 at 08:49 AM

*- Outside of specification**-This limit was used in the evaluation of the final result for the blank(1) The result for one or both determinations was less than five times the LOQ.(2) The unspiked result was more than four times the spike added.

Unspiked (UNSPK) = the sample used in conjunction with the matrix spikeBackground (BKG) = the sample used in conjunction with the duplicate

MS MSD MS/MSD RPD BKG DUP DUP Dup RPDAnalysis Name %REC %REC Limits RPD MAX Conc Conc RPD Max___

Batch number: 08014A07A Sample number(s): 5255498-5255504 UNSPK: 5255498TPH by NWTPH-Gx waters 118 63-154

Batch number: 080166050002A Sample number(s): 5255498-5255504 UNSPK: P253903 BKG: P253903Lead 99 99 75-125 1 20 1.5 1.6 4 (1) 20

Batch number: N080142AA Sample number(s): 5255498-5255502 UNSPK: P255489Ethanol 110 32-164Methyl Tertiary Butyl Ether 103 69-127di-Isopropyl ether 112 68-129Ethyl t-butyl ether 109 78-119t-Amyl methyl ether 104 72-125t-Butyl alcohol 100 70-121Chloromethane 120 47-133Vinyl Chloride 129 55-130Bromomethane 96 52-129Chloroethane 109 57-130Trichlorofluoromethane 120 67-1501,1-Dichloroethene 115 87-145Methylene Chloride 103 79-133trans-1,2-Dichloroethene 107 82-1331,1-Dichloroethane 117 85-135cis-1,2-Dichloroethene 103 83-126Chloroform 110 83-1391,1,1-Trichloroethane 114 81-142Carbon Tetrachloride 113 82-149Benzene 110 83-1281,2-Dichloroethane 117 70-143Trichloroethene 109 83-1361,2-Dichloropropane 110 83-129Bromodichloromethane 108 80-137Toluene 107 83-1271,1,2-Trichloroethane 100 77-125Tetrachloroethene 105 78-133Dibromochloromethane 102 82-119Chlorobenzene 106 83-120Ethylbenzene 110 82-129m+p-Xylene 106 82-130o-Xylene 105 82-130Bromoform 86 64-1191,1,2,2-Tetrachloroethane 98 73-1211,3-Dichlorobenzene 105 79-1231,4-Dichlorobenzene 104 81-1221,2-Dichlorobenzene 101 82-117trans-1,3-Dichloropropene 99 77-123cis-1,3-Dichloropropene 102 80-126Freon 113 125 78-146

Batch number: N080161AA Sample number(s): 5255503-5255504 UNSPK: 5255503Ethanol 114 32-164Methyl Tertiary Butyl Ether 102 69-127di-Isopropyl ether 114 68-129Ethyl t-butyl ether 109 78-119t-Amyl methyl ether 103 72-125

Page 4 of 6

Quality Control Summary

Client Name: ConocoPhillips Group Number: 1073037Reported: 01/23/08 at 08:49 AM

*- Outside of specification**-This limit was used in the evaluation of the final result for the blank(1) The result for one or both determinations was less than five times the LOQ.(2) The unspiked result was more than four times the spike added.

Sample Matrix Quality ControlUnspiked (UNSPK) = the sample used in conjunction with the matrix spikeBackground (BKG) = the sample used in conjunction with the duplicate

MS MSD MS/MSD RPD BKG DUP DUP Dup RPDAnalysis Name %REC %REC Limits RPD MAX Conc Conc RPD Max___t-Butyl alcohol 105 70-121Chloromethane 125 47-133Vinyl Chloride 133* 55-130Bromomethane 110 52-129Chloroethane 116 57-130Trichlorofluoromethane 131 67-1501,1-Dichloroethene 113 87-145Methylene Chloride 102 79-133trans-1,2-Dichloroethene 105 82-1331,1-Dichloroethane 115 85-135cis-1,2-Dichloroethene 103 83-126Chloroform 112 83-1391,1,1-Trichloroethane 113 81-142Carbon Tetrachloride 111 82-149Benzene 111 83-1281,2-Dichloroethane 117 70-143Trichloroethene 108 83-1361,2-Dichloropropane 110 83-129Bromodichloromethane 107 80-137Toluene 107 83-1271,1,2-Trichloroethane 100 77-125Tetrachloroethene 104 78-133Dibromochloromethane 101 82-119Chlorobenzene 105 83-120Ethylbenzene 110 82-129m+p-Xylene 105 82-130o-Xylene 105 82-130Bromoform 84 64-1191,1,2,2-Tetrachloroethane 97 73-1211,3-Dichlorobenzene 102 79-1231,4-Dichlorobenzene 102 81-1221,2-Dichlorobenzene 100 82-117trans-1,3-Dichloropropene 100 77-123cis-1,3-Dichloropropene 102 80-126Freon 113 123 78-146

Surrogate Quality ControlSurrogate recoveries which are outside of the QC window are confirmedunless attributed to dilution or otherwise noted on the Analysis Report.

Analysis Name: TPH by NWTPH-Dx(water) w/SiGelBatch number: 080140011A

Orthoterphenyl__________________________________________________________________________________________________________5255498 935255499 995255500 975255501 1035255502 98

Page 5 of 6

Quality Control Summary

Client Name: ConocoPhillips Group Number: 1073037Reported: 01/23/08 at 08:49 AM

*- Outside of specification**-This limit was used in the evaluation of the final result for the blank(1) The result for one or both determinations was less than five times the LOQ.(2) The unspiked result was more than four times the spike added.

Surrogate Quality ControlBlank 98LCS 107LCSD 113__________________________________________________________________________________________________________Limits: 50-150

Analysis Name: TPH by NWTPH-Dx(water) w/SiGelBatch number: 080140012A

Orthoterphenyl__________________________________________________________________________________________________________5255503 995255504 102Blank 98LCS 107LCSD 114__________________________________________________________________________________________________________Limits: 50-150

Analysis Name: TPH by NWTPH-Gx watersBatch number: 08014A07A

Trifluorotoluene-F__________________________________________________________________________________________________________5255498 1105255499 1115255500 1115255501 147*5255502 1075255503 1095255504 109Blank 104LCS 110LCSD 114MS 120__________________________________________________________________________________________________________Limits: 63-135

Analysis Name: EPA SW846/8260 (water)Batch number: N080142AA

Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene__________________________________________________________________________________________________________5255498 92 90 94 955255499 91 89 94 965255500 92 90 94 955255501 93 89 94 985255502 92 89 94 96Blank 92 90 94 96LCS 93 90 96 97LCSD 93 91 96 97MS 93 92 96 97__________________________________________________________________________________________________________Limits: 80-116 77-113 80-113 78-113

Analysis Name: EPA SW846/8260 (water)Batch number: N080161AA

Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene__________________________________________________________________________________________________________5255503 92 89 94 965255504 92 89 94 96

Page 6 of 6

Quality Control Summary

Client Name: ConocoPhillips Group Number: 1073037Reported: 01/23/08 at 08:49 AM

*- Outside of specification**-This limit was used in the evaluation of the final result for the blank(1) The result for one or both determinations was less than five times the LOQ.(2) The unspiked result was more than four times the spike added.

Surrogate Quality ControlBlank 92 88 95 96LCS 93 89 96 98LCSD 93 90 97 97MS 92 88 97 97__________________________________________________________________________________________________________Limits: 80-116 77-113 80-113 78-113

Lancaster LaboratoriesExplanation of Symbols and Abbreviations

The following defines common symbols and abbreviations used in reporting technical data:

N.D. none detected BMQL Below Minimum Quantitation LevelTNTC Too Numerous To Count MPN Most Probable Number

IU International Units CP Units cobalt-chloroplatinate unitsumhos/cm micromhos/cm NTU nephelometric turbidity units

C degrees Celsius F degrees FahrenheitCal (diet) calories lb. pound(s)

meq milliequivalents kg kilogram(s)g gram(s) mg milligram(s)

ug microgram(s) l liter(s)ml milliliter(s) ul microliter(s)m3 cubic meter(s) fib >5 um/ml fibers greater than 5 microns in length per ml

< less than – The number following the sign is the limit of quantitation, the smallest amount of analyte which canbe reliably determined using this specific test.

> greater than

ppm parts per million – One ppm is equivalent to one milligram per kilogram (mg/kg), or one gram per million grams.For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter ofwater has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter ofgas per liter of gas.

ppb parts per billion

Dry weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weightbasis concentration to approximate the value present in a similar sample without moisture.

U.S. EPA data qualifiers:

Organic Qualifiers Inorganic Qualifiers

A TIC is a possible aldol-condensation product B Value is <CRDL, but �IDLB Analyte was also detected in the blank E Estimated due to interferenceC Pesticide result confirmed by GC/MS M Duplicate injection precision not metD Compound quatitated on a diluted sample N Spike amount not within control limitsE Concentration exceeds the calibration range of S Method of standard additions (MSA) used

the instrument for calculationJ Estimated value U Compound was not detectedN Presumptive evidence of a compound (TICs only) W Post digestion spike out of control limitsP Concentration difference between primary and * Duplicate analysis not within control limits

confirmation columns >25% + Correlation coefficient for MSA <0.995U Compound was not detected

X,Y,Z Defined in case narrative

Analytical test results for methods listed on the laboratories’ accreditation scope meet all requirements of NELAC unlessotherwise noted under the individual analysis.

Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiologicalanalysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, thetest results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contactus. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of ourstaff. This report shall not be reproduced except in full, without the written approval of the laboratory.

WARRANTY AND LIMITS OF LIABILITY – In accepting analytical work, we warrant the accuracy of test results for the sample as submitted.THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED ORIMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FORPARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLEFOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSSOF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF LANCASTERLABORATORIES AND (B) WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCHDAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other orderfor work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions ofLancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client.