Company Introduction Hebei Create Instrumentation
Technologies Co., Ltd. is a
professional developer and
manufacturer of Industrial
on-line instruments since 1988,
such as: Conductivity/
Resistivity meter, pH /ORP
meter, Reverse Osmosis controller, Flow meter and Sensors. Our instruments could
be widely used in: Water treatment, Electronic power, chemical industry, Pharmacy,
Environment protection.
We have substantial market share in China, almost70%. Our instruments are popular,
not only in China, but also in International market. With strong scientific and
technical strength, our products have been exported to more than40 countries
covering Asia, Europe, American, Oceania, and Africa. Our instruments earn good
reputation in domestic and aboard market due to high quality and reasonable price.
Our company has a high-level team for
technology researching &developing , a high
efficient group for quality control ,production
management and sale & service and
possesses advanced production line for
inserting, installing, SMT, soldering and after making and facilities for measure,
demarcating and check.
We take customers and quality as our life and
improve products continuously and create new
series products. With 20 years of history, we are
always advancing higher and pursuing excellence
and hold operation principle of technology
innovation, reliable service and customers first to
serve customers and friends. We are doing every effort to thank good cooperation
and great support of many years from our customers with our continuous process,
good products, competitive price and
circumspect service.
Honors:
1988 First patent of Industrial Pure water
conductivity
2003 Hebei Technology Innovation Enterprise of Measurement Instruments Industry
2004 Hi-tech Enterprise of Hebei Province and honor the Financing and Technical support.
2005 ISO9001:2000 system accreditation
2006 CE accreditation
SERIES OF Industrial Circulation Cooling Water Controller DCK-6500 Industrial Circulation Cooling Water Controller Features and application
The DCK-6500 is a kind of intelligent controller for conductivity measurement and Chemicals dosing of industrial circulation cooling water.
The meter is not only used for the Conductivity & Temperature measurement of the Enclosed type circulation cooling water systems and Opening type systems , but also widely used for the adjustment of water chemical dosing. Be based on monitoring the conductivity value of the industrial circulation cooling water to control the concentration multiple of the cooling water, and then drainge and water supplement in time. Control the dosing According to the time proportion, the drainge, the water supplement to cuculate the dosing , which will protect the pipeline from corrsion , improve the heat exchange efficiency, reduce the energy consumption.
The meter is widely used for the circulation cooling water system of Central Air-condictioning,Petroleum Chemical Industry, Metallurgy, Thermo Power plants, Chemical fertilizer plant.
Conductivity over-limited warning; No reagent warning; circulationg water over temperaure warning Multi-sensors conductivity measurement; strong ability of anti-pollution; large measurement range ; high level accurate. The double channels of the measurement will offer the data of water supplyment, drianage and so on. Corrosion inhibitor, sterilizing agent will be dosing by timing. The measurement data could be record for the paperless function.
Main technical index Protect level IP65 ( The diameter of the wire that connect with the terminal
should be ≥5mm)
Conductivity measurement
Measurement range:200~ 20000μS/cm (0~ 25000ppm) Temperature compensation:0 ~ 50 (273~ 323K) Sensor:Multi-Conductivity sensor Accurate:±5% (FS) ± 1Digits Material: Titanium Cleaning:Ultrasonic cleaning Components of temperature measurement:Pt1000 Accurate:±1
Temperature measurement of Circulating water. Measurement range:0 ~ 60 (273~333K) Sort of Chemicals Dosing the Corrosion inhibitor on the drain/water supplement:
Double channels adding Dosing the sterilizing agent time period: One channel
Flow meter pulse signal:Double channels (one is for drainage, the other one is for water supplyment)
Switch of low liquid leve( solution box):triplicate channels Switch of flux ( NO type ):one channel
Switching value signal input
Switch of liquid level ( NO type ):double channels Metering pump control output: triplicate channels Solenoid valve control output:triplicate channels Alarm control output:one channel
Switching value signal output
Ultrasonic cleaning control output:one channel Analog output 0~20mA isolated output (corresponding to the conductivity):
one channel ( load capacity≤400Ω) Communication port RS-485 serial port:one channel Port 320x240 LCD screen with background light; 6 pieces of press keys Working environment Temperature: 0 ~ 60 ; Humidity:≤80% RH Power supply AC 220V±10% 50Hz; Power consumption:≤10W Dimension 320×260×129mm Weight 5.3kg Installation Wall hanging.
DCK-6600 Industrial Circulation Cooling Water Controller Features and applications:
The DCK-6600 is a kind of intelligent controller for conductivity measurement and Chemicals dosing of industrial circulation cooling water.
The meter is not only used for the Conductivity & Temperature measurement of the Enclosed type circulation cooling water systems and Opening type systems , but also widely used for the adjustment of water chemical dosing. The double channels of the measurement will offer the data of water supplyment, drianage and so on. Multi-sensors conductivity measurement; strong ability of anti-pollution; large measurement range ; high level accurate. The RS485 data port could work with the epigyny device to transfer data to the PC computer for Network remote control and setti
Main features and applications: Protect leverl IP65 The diameter of the wire that connect with the terminal should
be≥5mm)
Conductivity measuremnt
Measurement range:200~ 20000μS/cm (0~ 10000ppm) Temperature compensation range:0~ 50 (273~ 323K) Sensor:Multi-conductivity sensor Accurate:±5%±1Digitals Material:Titanium Cleaning :Ultrasonic cleaning
pH measurement
Sensor :pH sensor Measurement range:2~ 12pH Accurate:0.1pH Measurement resolution:0.01pH Stability:±0.05pH/24h Working temperature:-15-80 Max pressure:0.6MPa Life span:1 Year Components of temperature measurement:Pt1000 Accurate:±1
Temperature measurement
Measurement range:0 ~ 100 (273~373K) Flow meter pulse signal:double channels
Switch of Flux ( Normally Open type ) :one channel Switch value signal input
Swith of Liquid level ( Normally Open type ):double channels
Solenoid control output:double channels Warning control output:one channel
Switch value signal output
pH dosing :one channel
Ultrasonice cleaning control output :one channel Anolog output 0~20mA isolated output (corresponding to the conductivity) :
one channel (Load capacity≤500Ω) Communication port RS-485 serial port:one channel port 240x160 LCD screen with background light; 6 pieces of press keys Working condictions. Temperature:0 ~ 60 ; Humidity:≤80% RH Power supply AC 220V±10% 50Hz; power consumption:≤10W Demension 235×185×119mm Installation Wall hanging
PMC-6100 Pool Water Controller Features and applications PMC-6100 is a kind of intelligent controller with microprocessor controlling. The meter is a Programmble controller that being used for the pH , ORP, temperature, liquid level, TDS measurement. The intelligent meter PMC-6100 could controlling and monitoring the water quality, temperature, water valume and dosing of the Hotel, Swimming pool, Hot spring... The meter needs less
spaces, less operation charge and easily operate.
Main technical index
Protect level IP65(The diameter of the wire that connect with the terminal should be≥5mm)
Conductivity measurement
Measurement range:200~ 20000μS/cm (0~ 10000ppm) Temperature compensation:0~ 50 (273~ 323K) Sensor:Multi-conductivity sensor Accurate:±5%±1Digitals Material:Titanium Cleaning:Ultrasonic cleaning
pH measurement
Sensor:pH sensor Measurement range:2~12pH Accurate:0.1pH Resolution:0.1pH Stability:±0.2pH/24h Working temperature:-15~80 Max pressure :0.6MPa Life span :1 Year
ORP measurement
Sensor:ORP sensor Measurement range :0 ~ 900mV Accurate:5mV Resolution:1mV Stability:±10mV/24h Working temperature:-15~80 Max pressure:0.6Mpa
Water temperature measurement
Sensor:Pt1000 Accurate:±0.5 Measurement range:0 ~ 56 (273~ 373K) Resolution:0.1 Stability:±1/24h
TDS measurement
Components of measurement:TDS sensor Accurate:±2% Measurement range:200 ~ 20000 ppm (mg/L) Resolution:±1% Stability:±2%/24h
Switching value signal input
Dosing solenoid control output: triplicat channels Circulationg pumps control output: double channels Water supplement control output: one channel Heat exchanger control output: on channel
Anoloy output 0~20mA isolated output(corresponding to the conductivity): one channel ( capacity load≤500Ω)
Communiction port RS-485 serial port: one channel
port 240x160 LCD screen with background light; 6 pieces of press key Working environment
Temperature :0 ~ 60 ; Humidity :≤90% RH
Power supply AC 220V±10% 50Hz; Power consumption:≤10W
Demension 235×185×119mm
Installatin Wall hanging.
SERIES OF CONDUCTIVITY METER DCK-8550 Conductivity Controller Main features: DCK-8550 Midlevel Intelligent Network Model industrial on-line conductivity controller is a top
grade meter used for continuous measuring and controlling of industrial flow water quality. Main Technical Specifications: Conductivity measurement range:
0.1cm-1: 0.00μS -400.0μS,
1.0cm-1 : 0.00μS -4000μS,
10cm-1 : 0μS -40.00ms
Temperature measure range: 0~50
Accuracy: 1.0 %( FS)
Stability: ±2×10-3(FS)/24h
Auxiliary electrode: 0.1cm-1, 1.0cm-1 or
10.0cm-1 and with the match of PT100 three
wires platinum resistance thermometer sensor
Operation pressure of conductance cell: 0~0.5 MPa
Medium temperature: 5~50
Temperature compensation: automatic compensation, with 25 as standard
Cable composition: RVP+ coaxial cable 75-2 (double shielding)
Cable length: 5m or on agreement _ m
Display mode: the conductivity value、 temperature、 time and date、operating status and current mA
values on the LCD (Liquid Crystal Display) screen at the same time
LCD back-light brightness: 5 levels to be selected
4~20mA output: active or passive output, isolated, adjustable, reversible 4~20mA output
Alarm output mode: open collector/ set electrode, light isolated output: the maximum value 300mA,
the maximum value of up-pull voltage 24VDC (direct current), high/low alarm with adjustable of
return.
Maximum speed of frequency output: 400pulses/minute, used for driving adding medicine pump
Environmental Condition: temperature: 0~50 ; humidity: ≤85% RH
Temperature compensation components: PT100 three wires platinum resistance thermometer sensor
Power supply: DC24V (±4V)
Outline dimension: 96 × 96 × 103mm (height × width × depth)
Slot dimension for installation: 91 × 91mm (height × width) Installation: Jam-in
DCK-8520 Series of Double Channels Intelligent Network Conductivity Controller
Main features:
The double channels conductivity
monitor/controller can measure the value of
inflow water conductivity, outflow water
conductivity, desalination, current water
temperature, optional display double channel
resistivity, double channel TDS. 128×64 matrix
LCD display, English menu display, flexible
rubber key-press with good hand feeling, and also
with water-proof function. It is widely used for
power factory, chemicals, pharmacy,
environmental protection, metallurgy, paper
making, food and water supply etc.
Main technical specifications: The conductivity measure range of the inflow and outflow (double channels) water: 0.00~200.0μS/cm (0.1cm-1 electrode); 0.00~2000μS/cm (1.0cm-1 electrode); 0~20.00mS/cm (10.0cm-1 electrode); Accuracy: 1.5 %( FS) Stability: 1×10-3(FS)/24h; Operation pressure of the conductance cell: 0~0.5MPa; Media temperature: 5~50 Temperature compensation: calculate compensation according to mathematic model, with 25 as standard condition; Display Mode: double channels conductivity display, double channels resistivity display, double channels TDS display, desalination, temperature, alarm state and current mA value etc. Values displayed separately on LCD screen; LCD backlight brightness: adjustable 5 grade, touchable point lightness; 4-20mA output: selectable between instrument mode and transmitter mode, isolated, transferable, reversible; Alarm output mode: relay output, high/low limit alarm with adjustable of returns; Environmental conditions: temperature: 0~50; Humidity: ≤90%RH; Power supply: DC 24V (±4V); Outline dimensions: 96×96×103mm (height × width × depth); Slot dimension for installation: 91×91mm (height × width) Installation : Jam-in
DCK-7161 Conductivity +Temperature Double Windows Controller
Main features: DCK-7161 conductivity instrument is an online measuring and control instrument for water quality
conductivity of industrial process, which combines the measurement of conductivity and fluid
temperature. Its functions include electrode
constant selection and input through keyboard,
temperature compensation factor setting, range
selection, conductivity over limit alarming and
control setting, etc. The instrument is widely used
in pharmacy, chemical industry, electronic
industry, food and beverage industry, etc. for
monitoring of pure water, especially for water
production monitoring of reverse osmosis system.
Main technical specifications Measuring range: 0~20、0~200、0~2000μS/cm(1.0cm-1 electrode) 0~2、0~20、0~200μS/cm(0.1 cm-1 electrode)(Three steps of ranges, selected through keyboard) Accuracy: 1.5%(FS) Stability: ±2×10-3(FS)/24h Operation pressure of conductance cell: 0~0.5Mpa Medium temperature: 5~50 Automatic temperature compensation: calculate compensation according to mathematic model , with 25 as standard condition (when the temperature compensation factor is zero, there is no temperature compensation for measurement) Power supply: AC 220V±10% 50Hz Power consumption: ≤2W Output current signal: isolated output 4~20mA, switchable between active and passive output (ex-factory setting is active output) Display mode: red LED digit double-window display, 3½ digits for conductivity, 3 digits for temperature Control output mode: ON/OFF relay output Load capacity of the relay: AC230V/7A Max; AC115V/10A Max. Environment conditions: temperature: 0~50;humidity: ≤85%RH Electrode configured: 1.0cm-1 plastic electrode, 0.1cm-1 stainless steel electrode Screw thread size: 1/2"NPT (pipe thread) Cable structure: RVP+ coaxial cable 75-2 (double shielding) Cable length: normal 5m or specified as ______m Auxiliary printer:WDJ-4680 paperless recorder + printer Dimension:96×96×130 mm ( height×width×depth) Slot dimension for installation: 91×91 mm ( height×width) Installation: Jam-in
DCK-7261 Double Channels Conductivity+Temperature Double Windows Controller Features Double electrodes and double channels conductivity controller. With functions of jam-in microchip for measure, calculating and display of multi parameters (inflow water conductivity, outflow water conductivity, desalinization and real time temperature). Menu-driven operation, keyboard type setting and modification of parameters (electrode constant check, temperature compensation factor, conductivity over limit alarm setting and signal output). It is widely used in reverse osmosis system for continuous measurement and analysis of inflow water, outflow water, temperature, and desalinization ratio. Main Technical Specifications Measurement range: Inflow water measure range: 0~2000, 0~200μS/cm Outflow water measure range:0~200, 0~20μS/cm Auxiliary Electrode: Inflow water electrode constant: 1.0cm-1 Outflow water electrode constant: 0.1cm-1 Accuracy: 1.5 %( FS) Stability: ± 2×10-3(FS)/24h Medium temperature: 5~50 Medium pressure : 0~0.5 MPa Thread dimension: 1/2 inch pipe thread Temperature compensation: digital compensation with 25 as standard condition Display mode: Red LED digit double windows Display, Conductivity: 3.5Bit, Temperature: 3 bit Contact point mode: ON/OFF, 5A/250V AC Digital communication: RS 485 data output. Analog Signal: isolated 4-20 mA output analog quantity output (meter mode). The in-flow water, outflow water channels could be selected. Controlling mode: Inflow water conductivity Hi/Lo limit alarm, ON/OFF relay output. Outflow Water conductivity Hi/Lo limit alarm, ON/OFF relay output. Backlash treatment:Conductivity Hi-limit alarm; without action backlash, prevention of critical shake. Auxiliary printer: WDJ-4680 paperless recorder + printer Environment conditions: temperature: 0~50;humidity ≤85%RH Power supply: AC 220V±10% 50Hz Outline dimensions: 96×96×130mm (height × width × depth) Slot dimension for installation: 91×91mm (height × width) Installation: Jam-in
DCK-4230/4231/4232/4332 Conductivity Meter
Main features: DCK-4000 series conductivity meter is an online measuring and control instrument for water quality conductivity of industrial process. It is widely used for reverse osmosis, electrolysis, desalination of sea water; recycle water and continuously monitoring for various water treatment equipment. DCK-4000 Series comparison Table
Model 4-20mA Output mode Relay output Measurement range Range switch
DCK-4230 None-isolated Instrument mode No 0-20,0-200,0-2000 Manual
DCK-4231 No No Yes 0-20,0-200,0-2000 Manual and Automatic
DCK-4232 None-isolated Instrument mode Yes 0-20,0-200,0-2000 Manual and Automatic
DCK-4332 Isolated Instrument and
Transmitter modeYes 0-20,0-200,0-2000 Manual and Automatic
Main Technical Specifications Conductivity Measuring range: 0~20、0~200、0~2000μS/cm(1.0cm-1 electrode) 0~200、0~2000μS/cm、0~20mS/cm (10.0cm-1 electrode)
(Three steps of ranges, selected through keyboard) Temperature measuring range: 0~60 Accuracy: 1.5%(FS) Stability: ±2×10-3(FS)/24h Operation pressure of conductance cell: 0~0.5Mpa Medium temperature: 5~50 Automatic temperature compensation: calculate compensation according to mathematic model , with 25 as standard condition (when the temperature compensation factor is zero, there is no temperature compensation for measurement) Power supply: AC 220V±10% 50Hz Power consumption: ≤2W Output current signal: isolated output 4~20mA, switchable between active and passive output (ex-factory setting is active output) Display mode: 3½ digits for conductivity, 3 digits for temperature Contact capacity: 3A/250V AC (for resistive load) Environment conditions: temperature: 0~50;humidity: ≤85%RH Electrode configured: 1.0cm-1 plastic electrode Screw thread size: 1/2"NPT (pipe thread) Cable structure: RVP+ coaxial cable 75-2 (double shielding) Cable length: normal 5m or specified as ______m Outline dimensions:96×96×130 mm ( height×width×depth) Slot dimension for installation: 91×91 mm ( height×width) Installation: Jam-in
DCK-3900 High-temperature Conductivity/Resistivity Double Windows Controller Performance features Temperature + conductivity + resistivity controller. Electrode consistent check can be met by jam-in Microchip. Conductivity/resistivity can be displayed optionally. Conductivity/resistivity and temperature over limit alarm can be set optionally. Conductivity/resistivity can be displayed at the same time with double-line LED digital canal. With function of digit calculating temperature compensation, it can preset and modify compensation parameters. Conductivity/resistivity at temperature of 25 or 90 can be displayed optionally. It is with features of stability of high temperature and reliable long time operation. Main Technical Specifications Measuring range: Conductivity : 0~20μS/cm Resistivity : 0.05~18.25 MΩ·cm Accuracy: 1.0%(FS) Stability: ±2×10-3(FS)/24h Auxiliary electrode: 0.1cm-1 High temperature sanitation 316 L stainless steel Medium temperature: 70~150 Temperature compensation : Automatic temperature compensation: calculate compensation with 90 as standard condition Power supply: AC 220V±10% 50Hz Power consumption: ≤4W Data connection port: RS485 port, Modbus agreement Output current signal: isolated output 4~20mA, switchable between active and passive output Maximum load impedance: 500Ω Max@ 24V DC Display mode: Red LED digit double-window display Contact capacity: 5A/250V AC (for resistive load) Environment conditions: temperature: 0~50;humidity: ≤85%RH Screw thread size: 1/2"NPT (pipe thread) Cable structure: RVP+ coaxial cable 75-2 (double shielding) Cable length: normal 5m or specified as ______m working pressure of conductance cel:0~1.0MPa Control output: ON/OFF double channels relay output. Load capacity of the relay: AC230V/7A Max; AC115V/10A Max. Auxiliary printer: WDJ-4680 paperless recorder+ printer Dimensions:96 × 96 × 130mm (height × width × depth) Slot dimensions for installation:91 × 91mm (height × width) Installation: Jam-in
CM-230(330)X Series Intelligent Conductivity Meter Performance features CM-230(330)X series intelligent on-line conductivity meter, it is the upgrade substitute meter of
CM230、CM-230SX 、330、
240、340.
It has keyboard setting electrode
constant , high、low limit alarm,
transferable 4~20mA current
signal output , checking the
media temperature、μS/cm and
ppm (TDS)conversion through
the switching keys,automatic range conversion,three types of constant to be chosen
(0.1cm-1、1.0 cm-1、10.0 cm-1),larger measurement range.
It has ultra steady measurement collecting,large temperature range、low excursion design,can
switch conductivity/ temperature/TDS under the measurement condition,can give an alarm when the
water quality is over standard,high brightness back-light LCD display.
It is used for on-line monitoring and controlling of reverse osmosis 、electrodialysis、ion exchange
producing water system、cooling water control system and industrial water..
Model and performance function:
Function/model
Non-isolated
4mA signal
output
Automatic
measurement
range
Hi-limited
alarm setting
Hi/Lo
limited
alarm setting
Units of the
measurement
Probe
Constant
CM-230A
CM-230C
CM-230D
CM-330C
Main technical specification: Measurement range:
Conductivity: 0~19.99 0~199.9μS/cm (0.1cm-1 electrode)
0~19.99 0~199.9、0~1999μS/cm (1.0 cm-1 electrode)
0~199.9μS/cm 0~1999μS/cm 0~19.99mS/cm (10cm-1 electrode)
Temperature: 0-50
Auxiliary electrode:
1.00cm-1 plastic platinum gold electrode,1/2″(1/2 inch)pipe screw connection;
1.00cm-1 stainless steel electrode,1/2″(1/2 inch)pipe screw connection;
10.0 cm-1 Teflon platinum electrode,3/4″(3/4 inch)pipe screw connection;
The length of the cable:5m as ex work standard figure or according to the user’s specification;
Medium pressure:0~0.5MPa;
Medium temperature:0~50;
Component of temperature compensation:NTC;
Display mode:conductivity:3.5-bits LCD Digit display,temperature: 3- bits Digit display;
Accuracy:1.5%(FS)
Stability:±2×10-3(FS)/24h;
Temperature compensation:Digit calculating compensation, with 25 as the reference
temperature;
Output signal :non- isolated,transferable 4~20mAcurrent;
Maximum load impedance :300Ω Max@ DC 9V ;
Relay load capacity:AC 230V/5A Max (without electromagnetic induction);
Output control model:ON/OFF two contacts relay output;
Power supply :AC 220V±10%,50Hz;
Power consumption:2W
Environment conditions:Temperature:0~50; Humidity:≤85%RH;
Outline dimension:48×96×100mm(height×width×depth)
Slot dimension for installation:45×91mm(height×width)
Installation: Jam-in
CM-230 Conductivity Monitor
Performance features This instrument is a panel instrument for on-line monitoring of industrial process conductivity. Range switch over and constant check can both be freely set and adjusted through the operation component on the rear panel; unique signal collecting and processing technology and special thick film circuit are adopted to make measurement accurate and operation stable; there are also other features such as linearzed data, automatic temperature compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications Measurement range: 0~20 0~200 0~2000μS/cm
Accuracy 1.5% (FS)
Stability ±2 × 10-3 (FS) / 24h
Auxiliary electrode Plastic structure; constant: 1.0cm-1
Temperature compensation NTC
Medium temperature 5~50
Output signal Non-isolated 4-20mA signal output
Maximum load impedance 300Ω Max@ 24V DC, instrument mode
Thread dimension 1/2〃pipe thread
Medium pressure 0~0.5Mpa
Cable composition RVP + coaxial 75-2 double shielding
Cable length 5m or on other agreement (5~30m)
Temperature compensation Automatic compensation, with 25 as the reference temperature
Display Back light 3.5-bit LCD
Power supply AC 220V ±10% 50Hz
Power consumption ≤1W
Environment conditions Temperature: 5~50 ;Humidity: ≤85%RH
Dimensions 48 × 96 × 100mm (height × width × depth)
Slot dimensions for 45 × 91mm (height × width)
Installation Jam –in
CM-230SX Hi/Lo Limited Conductivity Controller
Performance features This instrument is a panel instrument for online monitoring of industrial process conductivity. The measurement range and constant has been set by original manufacturer. It can be set alarm for high or low limit of conductivity .It has automatic temperature compensation with 25 as reference temperature. It features stable operation and accurate measurement. And it is widely used in online monitoring of water quality for electrodialysis, reverse osmosis system and common pure water producing system. It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications Measurement range: 0~20μS/cm,0~200μS/cm,0~2000μS/cm (Fixed range which has been set by the manufacturer can not be changed by customers: So please indicate which measure range will be needed before placing an order)
Accuracy:1.5% (FS)
Stability:±2 × 10-3(FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50
Control output mode: ON/OFF relay output
Relay load capacity: AC 230V/7A Max ; AC 115V/10A Max
Thread dimension:1/2″pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shielding
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25 as the reference temperature
Display:3.5-bit LCD
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 5~50;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-232 Double Channels Conductivity Monitor Performance features This instrument is a panel instrument for on-line monitoring of industrial process conductivity. Measurement range and constant check have been adjusted by manufacturer. Easy installation and operation, accurate measurement and stable operation. There are also other features such as linearized data, automatic temperature compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary instrument of various types of small pure water equipment. Main technical specifications Measurement range: Inflow water: 0~200μS/cm outflow water: 0~20μS/cm
Inflow water: 0~2000μS/cm outflow water: 0~200μS/cm
Accuracy 1.5% (FS)
Stability ±2 × 10-3 (FS) / 24h
Auxiliary electrode Plastic structure; constant: 1.0cm-1
316 L stainless steel constant: 0.1cm-1
Temperature compensation component
NTC
Medium temperature 5~50
Thread dimension 1/2〃pipe thread
Medium pressure 0~0.5Mpa; 0~1.0Mpa
Cable composition RVP+ coaxial 75-2 double shield
Cable length 5m or on other agreement(5~30m)
Temperature compensation Automatic compensation , with 25 as the reference temperature
Display 3.5-bit LCD
Power supply AC 220V ±10% 50Hz
Power consumption ≤1W
Environment conditions Temperature: 5~50 ;Humidity: ≤85%RH
Dimensions 48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation 45 × 91mm (height × width)
Installation Jam-in
CMS-230 High Salinity Conductivity Monitor Performance features This instrument is a panel instrument for on-line monitoring of industrial process conductivity. Range switch over and constant check can both be freely set and adjusted through the operation component on the rear panel; unique signal collecting and processing technology and special thick film circuit are adopted to make measurement accurate and operation stable; there are also other features such as linearized data, automatic temperature compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary instrument of various types of small pure water equipment. Main technical specifications Measurement range: 0~20mS/cm (Note:1 mS/cm=1000μS/cm)
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50
Output signal: Non-isolated 4-20mA signal output
Maximum load impedance:300Ω Max@ 24V DC, instrument mode
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shielding
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25 as the reference temperature
Display: Back light 3.5-bit LCD
Power supply: AC 220V±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 0~50 ;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
:
TDS-230 Consistence Monitor Performance features This instrument is a panel instrument for on-line monitoring of industrial process consistence monitor. Range switch over and constant check can both be freely set and adjusted through the operation component on the rear panel; unique signal collecting and processing technology and special thick film circuit are adopted to make measurement accurate and operation stable; there are also other features such as linearized data, automatic temperature compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary instrument of various types of small pure water equipment. Main technical specifications Measurement range: 0~20 0~200 0~2000ppm
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shielding
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25 as the reference temperature
Display: Back light 3.5-bit LCD
Output signal: Non-isolated 4-20mA signal output
Maximum load impedance:300Ω Max@24V DC, instrument mode
Power supply: AC 220V±10% 50Hz
Power consumption:≤1W
Environment conditions Temperature: 5~50
Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-240 Conductivity Monitor Performance features This instrument is a panel instrument for on-line monitoring of industrial process conductivity. Range switch over and constant check can both be freely set and adjusted through the operation component on the rear panel; unique signal collecting and processing technology and special thick film circuit are adopted to make measurement accurate and operation stable; there are also other features such as linearized data, automatic temperature compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary instrument of various types of small pure water equipment. Main technical specifications Measurement range: 0~20 0~200 0~2000μS/cm
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50
Output signal: Non-isolated 4-20mA signal output
Maximum load impedance:300Ω Max@ 24V DC, instrument mode
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shield
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25 as the reference temperature
Display:3.5-bit Red LED
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 5~50 ;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-330 Conductivity Controller Performance features This instrument is a panel instrument
for on-line monitoring of industrial
process conductivity. Range switch
over and constant check can both be
freely set and adjusted through the
operation component on the rear panel;
unique signal collecting and processing
technology and special thick film
circuit are adopted to make
measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It has control function, including setting of over limit of conductivity, and the outputs are control
contacts. It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications
Measurement range:0~20, 0~200, 0~2000 (μS/cm) optional
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode:1.0cm-1 plastic electrode
Temperature compensation component: NTC
Medium temperature:5~50
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shield
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25 as the reference temperature
Display:3.5-bit LCD
Control output mode: ON/OFF relay output
Relay load capacity: AC 230V/7A Max ; AC115V/10A Max
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 0~50 ;Relative humidity: ≤85%
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-330D Conductivity Controller Performance features This instrument is a panel instrument for
on-line monitoring of industrial process
conductivity. Range switch over and
constant check can both be freely set and
adjusted through the operation component
on the rear panel; unique signal collecting
and processing technology and special thick
film circuit are adopted to make
measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It has control function, including setting of over limit of conductivity, and the outputs are control
contacts. It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications Measurement range 0~20, 0~200, 0~2000 (μS/cm) optional
Accuracy 1.5% (FS)
Stability ±2 × 10-3 (FS) / 24h
Display mode Back light 3.5 LCD digital display
Auxiliary electrode 1.0cm-1 plastic electrode
Thread dimension 1/2〃pipe thread
Control output mode ON single contact relay output
Relay load capacity AC 230V/5A Max; AC115V/10A Max
Environment conditions Temperature: 0~50 ;Relative humidity: ≤85%
Temperature compensation Automatic compensation, with 25 as the reference temperature
Power supply AC 220V ±10% 50Hz
Cable composition RVP + coaxial 75-2 double shielding
Operation pressure of conductance cell 0~0.5MPa
Cable length 5m or on other agreement
Dimensions 48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation 45 × 91mm (height × width)
Installation Jam-in
DDY-2327 Portable Conductivity Monitor Performance features This instrument is suitable for conductivity measurement of
outdoors. Multi-purpose software is adopted to make
measurement accurate and performance stable. It features
with such as floating digit, direct reading, and automatic
measurement range and temperature measurement.
Main technical specifications
Measurement range: 0~20μS/cm, 0~200μS/cm,
0~2000μS/cm (Measurement range switched over automatically)
Temperature range:0~50
Conductivity accuracy:1.5% (FS)
Temperature accuracy:0.5
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Medium temperature:0~50
Display:3.5-bit LCD
Power supply: DC 9V battery
Weight: About 150g (batteries not included)
(1) Environment conditions Temperature: 0~50
(2) Humidity: ≤85%RH
(3) No strong electro-magnetic field interference except earth magnetic field
Dimensions:150 × 70 × 25mm
Temperature compensation factor No Temperature compensation and Temperature compensation
could be set, conductivity value under temperature compensation factor: 0-7%.
It is powered off automatically each time running 5 minutes.
SERIES OF RESISTIVITY METER DRK-7361 Resistivity Controller
Features DRK-7361 is an instrument for online monitoring
and controlling resistivity of industrial process
water quality. It is a combination of resistivity and
temperature measurement. With jam-in microchip it
has functions of electrode constant input, check,
setting of resistivity over limit alarm and control
through keyboard. It is widely used for industrial
online measuring and controlling of ultra-pure water,
high-pure water in pharmacy and electronic
industry.
Main Technical Specifications Measurement range: 0~18.25MΩ·cm
Accuracy: 2.0 %( FS)
Stability: ±2×10-3(FS)/24h
Auxiliary Electrode: constant 0.05cm-1; sanitary 316L stainless steel titanium cylindrical electrode
Medium pressure: 0~0.5Mpa
Thread dimension: 1/2″pipe thread
Medium temperature: 5~50
Temperature compensation : Automatic compensation, with 25 as standard condition
Cable length: 10m or on other agreement _____m
Output signal: Isolated 4~20mA analog quantity output, (instrument mode).
Display mode: red LED digit double windows display, Resistivity: 3.5bit, Temperature: 3bit
Data communication: RS485 data connection port
With resistive load:500ΩMax@24V DC
Control output mode: ON/OFF relay output
Load capability of the relay: AC 230V/7A Max; AC 115V/10A Max
Auxiliary printer: WDJ-4680 paperless recorder + printer
Environment conditions: (1) temperature: 0~50 (2)humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Power spend: ≤4W
Dimensions:96×96×130mm (height × width × depth)
Slot dimension for installation: 91×91 mm ( height×width)
Installation: Jam-in
DRK-7461 Resistivity Controller Features
DRK-7461 is an instrument for online monitoring and
controlling resistivity of Industrial process water quality.
With jam-in microchip it has functions of electrode
constant input, check, setting of resistivity high limit
alarm and control through keyboard .It is widely used for
comparing and monitoring the quality change before
treatment and after treatment of EDI and anion-cation
exchange bed.
Main Technical Specifications
Measurement range: 0~18.25MΩ·cm
Auxiliary Electrode constant: 0.05cm-1
Accuracy: 2.0 %( FS)
Stability: ±2×10-3(FS)/24h
Medium temperature: 5~50
Temperature compensation: automatic compensation with 25 as standard condition
Data communication: RS485 data connection port
Signal output: Analog signal 4~20mA (load characteristics :500Ω Max@24V DC)
Control output Mode: ON/OFF double relays output
Load capability of the relay: AC 230V/7A Max; AC 115V/10A Max
Alarm Mode: resistivity low limit alarm and setting of action backlash can avoid critical shake
Auxiliary printer: WDJ-4680 paperless recorder + printer
Environment conditions: temperature: 0~50;humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Outline dimensions: 96×96×130mm (height×width×depth)
Slot dimension for installation : 91×91mm (height×width)
Installation: Jam-in
DRK-7561 Resistivity Controller Features It is an instrument for online measuring and controlling
conductivity/resistivity of Industrial process water quality.
With jam-in microchip it has functions of electrode
constant input ,check ,setting of resistivity high limit
alarm and control through keyboard .It is widely used for
comparing and monitoring the quality change before
treatment and after treatment of EDI , anion-cation
exchange bed and two grade reverse osmosis.
Main Technical Specifications Measurement range:
Resistivity : 0~18.25MΩ·cm Auxiliary electrode : 0.1 cm-1
Conductivity : 0~20μS/cm(conductivity) Auxiliary electrode: 0.05 cm -1
Accuracy: 1.5%(FS) (resistivity); 2.0 %( FS) (conductivity)
Stability: ±2×10-3(FS)/24h
Temperature compensation: automatic compensation with 25 as standard condition
Medium temperature: 5~50
Screw thread size: 1/2"NPT (pipe thread)
Medium pressure: 0~0.5Mpa
Cable structure: RVP+ coaxial cable 75-2 (double shielding)
Cable length: conductivity normal 5m or specified as ______m
Resistivity normal 10m or specified as ______m
Signal output: Analog signal 4~20mA (load characteristics :500Ω Max@24V DC), switchable
between active and passive output (ex-factory setting is active output)
Display: conductivity /resistiivity3.5 red LED, Temperature 3 red LED.
Control output Mode: ON/OFF double relays output
Environment conditions: temperature: 0~50 humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Power consumption: ≤4W
Load capacity of the relay:AC 230V/7A Max; AC115V/10A Max.
Auxiliary printer: WDJ-4680 paperless recorder + printer
Outline dimensions: 96×96×130mm (height×width×depth)
Slot dimension for installation : 91×91mm (height×width)
Installation: Jam-in
DRK-4000 Series of Resistivity Controller
Features DRK-4000 series controllers are the kind of intelligent industry on-line controllers. There is a flush type CMOS chip inside the controller for resistivity controlling, so the controller is rich of the software function. The controller could be set and controlled the Resistivity low-limited alarm; switch over the value of conductivity and resistivity; insulated transferable 4-20 MA current signal output; work as controller / transformer; work with the PLC / servo system conveniently ; Connect with all the 4-20 MA current signal output systems. Due to the nice appearance and the friendly operation mode, the DRK-4000 controller has special features. The controller has different kinds of the functions, competitive price and excellent performance; all these can meet the requirements of different level users. The controller can widely used in the measurement of EDI, Ion exchange, Hi-pure water, Ultra water… Technical Specification Measurement Range: Resistivity: 0~18.25MΩ·cm Conductivity: 0.050~2.0μS/cm Accurate: 2.0 %( FS) Stability: ±2×10-3(FS)/24h Auxiliary Electrode: constant 0.05cm-1; sanitary 316L stainless steel titanium cylindrical
electrode Medium temperature: 5~50 Temperature compensation : Automatic compensation, with 25 as standard condition Display mode: LCD digit double windows display, Resistivity/Conductivity: 3.5bit, (the conductivity value could be display transiently) Contact point mode: ON/OFF, 5A/250V AC Environment conditions: (1) temperature: 0~50 (2)humidity ≤85%RH Power supply: AC 220V±10% 50Hz Power spend: ≤3W Outline dimensions: 96×96×130mm (height × width × depth) Instrument panel hole: 92×92mm (height × width) Installation: Jam-in
Function
Technical Sheet
4-20mA signal output (Load characteristic)
Isolate Meter mode
output Transformer
output
Switch signal output
DRK-4220
DRK-4220A
DRK-4220C
Type
RM-220/320 CRM-420 CRC-520 Resistivity Monitor/Controller
Performance features
The instruments of this series are on-line panel-mode
high-purity water resistivity/conductivity instruments,
which is suitable for on-line water quality monitoring of
EDI and high-purity water produced by anion-cation
mixing and exchanging bed. It’s measurement accuracy
is high since it adopts unique signal collection and multi
automatic temperature compensation technologies; 316L stainless steel electrode is configured to
ensure long term and stable operation. It also has some optional functions such as control, alarm,
4~20mA electric current loop output, etc; its high-end
product adopts high performance SCM as processing
core for more stability and accuracy. It also has the
function of switching display between specific
conductance/resistance.
Type and basic function
RM-220 RM-320 CRM-420 CRC-520
Control, alarm × √ × √
4-20mA output √ × √ ×
Switching display between
conductance/resistance × × √ √
Main technical specifications Measurement range: 0~18.2MΩ·cm Accuracy: 2.0 %( FS) Stability: ±2×10-3(FS)/24h Supporting electrode parameters: Material: sanitary level 316L stainless steel Electrode constant: 0.05 cm-1 Output signal: 1) Switch quantity (a group of switching contact) 2) Analog quantity 4 ~ 20mA (load characteristics 0-300Ω) Temperature compensation: automatic
Type Option
function
compensation with 25 as standard condition Medium temperature: 5~50 Thread size: 1/2" pipe thread Medium pressure: 0~0.5MPa Cable structure: RVP+ coaxial cable 75-2 (double shielding) Cable length: 10m or specified as ______m Display mode: LCD display (ordinary type/background-light type) Power supply: AC 220V±10% 50Hz Power consumption: ≤1W Environment conditions: (1) temperature: 0~50 (2)humidity ≤85%RH Outline dimensions: 48×96×100mm (height×width×depth) Instrument panel hole: 45×91mm (height×width) Installation: Jam-in
REVERSE OSMOSIS PROGRAM CONTROLLER ROC-8221A Reverse Osmosis Controller Performance Features ROC-8221A is a combined control instrument of a single-stage reverse osmosis controller and double-channel on-line conductivity instrument. It can perform the operational test, status control and the on-line monitoring of inlet water, producing water, the temperature of the water and desalinization ratio of the water quality conductivity, displayed by LCD large screen. The interface is friendly, menu-driven operation is used; multiple group parameter can be set and modified. The requirement of automatic operation of the multiple controlling ways of the reverse osmosis system can be met. Main Technical Indexes: Reverse osmosis collection point: Raw water tank high level, raw water tank low level, low pressure alarm, high pressure alarm, pure water tank high level, pure water low level, pretreatment backflush chain; Reverse osmosis control point: inflow valve, low pressure pump, high pressure pump, flushing valve, conductivity over limit let valve Collect input signal mode: direct current power supply, pull electrical digit, all terminals are isolated . Conductivity Measurement Range:
1) inflow water 0~2000 μS/cm 2)Outflow water 0~20.00;0~200.0μS /cm (switched automatically)
Accuracy: 1.5 level Auxiliary electrode: 1.0 cm-1 Working pressure of conduct cell: 0~0.5 MPa Automatic temperature compensation:1~49°C Effective distance:≤30m (standard 5 m ,or ordered ahead) Displaying mode: LCD 128×64 backlight. Load capability of the relay: AC 250V/3A Max Power consumption: ≤3W Power supply : DC24V (±4V) Application environment : temperature 0~50 ; humidity ≤85%RH Outline dimension:96×96×103mm (height×width×depth) Slot dimension for installation: 91×91mm (height×width) Installation: Jam-in
ROC-8221 Reverse Osmosis Controller
Performance Features This instrument is a combined control instrument of a single-grade reverse osmosis controller and double-channel on-line conductivity instrument. It can perform the operational test, status control and the on-line monitoring of inflow water, producing water, the temperature of the water and desalinization ratio of the water quality conductivity, displayed by LCD large screen. The meter is easy to operate and menu-driven operation is used; multiple group parameters can be set and modified. The requirement of automatic operation of the multiple controlling ways of the reverse osmosis system can be met.
Main Technology Index Reverse osmosis collection point: Raw water tank high level, raw water tank low level, low pressure alarm, high pressure alarm, pure water tank high level, pure water low level, pretreatment backflush chain; Reverse osmosis control point: inflow valve, low pressure pump, high pressure pump, flushing valve, conductivity over limit let valve Collect input signal mode: direct current power supply, pull electrical digit, all terminals are isolated. Measurement range : inflow water 0~2000 μS/cm
outflow water 0~20、0~200μS/cm(switched automatically) Accuracy:1.5level Matching electrode: 1.0 cm-1 Working pressure of conduct cell:0~0.5 MPa Automatic temperature compensation:1~49°C Measuring distance:≤30m (standard 5 m ,or ordered ahead) Displaying mode: LCD 128×64 backlight ,displaying in English Load capacity of the relay: AC 250V/3A Max Power consumption : ≤3W Power supply :AC 220v ± 10% 50 HZ Application environment : temperature 0~50 ; humidity ≤85%RH Outline dimension: 96×96×130mm( height×width×depth) Slot dimension for Installation :91×91 mm(height×width) Installation : Jam-in
ROC-HY Reverse Osmosis Controller Operation Manual
Performance Features The instrument is a combination
controller of reverse osmosis and online
conductivity/resistivity meter. It can perform
the operation test of system, state
control and online monitoring of
conductivity/resistivity value(combination of PLC
and conductivity/resistivity meter). ROC-HY is
widely used in the one stage of RO system for
automatic management of RO+DI produce water ; the
management of Lab ultra water system.
Main Technology Index Reverse Osmosis collection point: Raw water no water protection, High pressure full water protection,Operation reposition. Reverse Osmosis control point: High pressure pump, Cycle pump, Flush valve, RO outlet valve,Disinfection valve, Disinfection discharge valve, DI pure water outlet valve, Internal cycle valve. Power supply: DC24V (a power switch should be installed before designing the shell) Power consumption: ≤7.2W Environmental condition: 1) temperature: 0~60; 2) humidity: ≤ 85% RH. Accuracy: 1.5 level Output contact capacity load: 5A/250V AC 3A/24V DC Updating rate of collecting result: ≤1sec/per time Working pressure of conductance cell: 0~0.2Mpa Automatic temperature compensation: 1~49 Interface mode: LCD display, English/sign display, touch key Measurement range TDS1 Raw water conductivity : 0-1000 ppm (auxiliary electrode 1.0 cm-1 ) TDS2 RO produce water conductivity: 0-100 ppm(auxiliary electrode 1.0cm-1) DI produce water resistivity: 0-18.2 MΩ·cm (auxiliary electrode 0.05cm-1) Return when over-time limit key. Under normal operation, not in the main interface, if there is no any key were pressed within 2 minutes, it will come back to the main menu automatically . Outline dimension: 90 × 150 × 46mm (height × width × depth) Slot dimension: 57 × 106mm (height × width) Installation: Panel
ROC-4313 Two stage reverse
osmosis conductivity controller
Performance Features The instrument is combination of two stage
reverse osmosis controller and on-line
conductivity monitor. It is a special-purpose
measurement and control system. This system
has the functions of automatic test, operation
test, status control, display, letter hint, indicating light display etc. The controller
aggregates all the advantages of PLC controller and the meter for measuring water quality. Main technical indexes
Reverse osmosis collecting point
Raw water tank level, middle tank level, no water protection, handle/automatic control, first stage pressurization pump low/high pressure protection, second stage pressurization pump high pressure protection, and so on.
Collecting input signal direct current power supply, pull electrical digit, all terminals are isolated .
Reverse osmosis controlling point
feed water pump, first-grade pressurization pump, second-grade pressurization pump, inlet water valve, pretreatment valve, flushing valve, first-grade over-limit outflow valve, second-grade over-limit outflow valve.
Measuring collection point raw water conductivity collect ,first-stage outlet water conductivity collect, and second-stage outlet water as well as temperature collection .
Measuring range
Raw water conductivity 0 ~ 20mS/cm 、 0 ~
2000μS/cm(match 10cm-1 or 1.0cm-1 electrode) first-stage reverse osmosis conductivity 0~200μS/cm(match 1.0 cm-1
electrode) second-stage reverse osmosis conductivity 0~20μS/cm(match 0.1cm-1 electrode)
Power supply voltage 24V DC (switch should be installed outside when designing)Accuracy 1.5 level Output control mode ON single contactor output Load capacity of output contact 5A/250V AC 3A/24V DC Rate of renewal of connecting ≤1second\time Operation pressure of conductance 0~0.5Mpa Temperature compensation automatic temperature with 25 as reference temperature Outline dimensions 130×180×60mm(height ×width ×depth) Slot dimension for installation 122×172mm (height× width) Installation control plate panel
ROC-3313 Reverse Osmosis Controller
Performance Features
The instrument is a combined control
instrument of a reverse osmosis controller and
an on-line conductivity instrument. It can
perform the operation test, status control and
on-line monitoring of water quality
conductivity (combining PLC controller and
conductivity meter). It takes multiple
anti-interference measures, adopts unique
process flow and graphical control panel with
LED indicator lamp embedded, the interface is
friendly; menu-driven operation is used, multiple groups of parameters can be set and modified, the
requirements of automatic operation are met.
Main technical specifications:
Reverse Osmosis collect point: raw water no water protection, low pressure protection, high
pressure protection, pure water tank high level protection, exterior operation, operation reposition
Reverse osmosis control point: raw water pump, high pressure pump, inflow valve, flush valve,
conductivity over limit let valve
Collecting input signal: direct current power supply, pull electrical digit, all terminals are isolated.
Power voltage: AC 220V±15% 50Hz Power consumption: ≤3W
Environment conditions: 1) temperature: 0~50; 2) humidity: ≤85%RH
Measuring range: 0~200μS /cm accuracy: 1.5 level
Controlling output mode: ON single contact relay output
Resistivity load impedance: AC 250V/3A Max.
Operation pressure of conductance cell: 0~0.5Mpa
Medium temperature:5~50
Temperature compensation: automatic temperature with 25 as reference temperature
Distance of measuring range: less than 30m (the ex-factory configuration of electrode cable is 5m
unless there is a special agreement)
Display mode: 3 1/2-digit LED digital display
Electrode selected: 1.0cm-1
Outline dimensions: 130×80×60mm (height×width×depth)
Slot dimension for installation: 122×172mm (height×width) Installation: Jam-in
ROC-2313 Reverse Osmosis Controller Performance Features The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation test, status control and on-line monitoring of water quality conductivity (combining PLC controller and conductivity meter). It takes multiple anti-interference measures, adopts unique process flow and graphical control panel with LED indicator lamp embedded, the interface is friendly; menu-driven operation is used, multiple groups of parameters can be set and modified, the requirements of automatic operation are met. Main technical specifications: Reverse Osmosis collect point: raw water no water protection, low pressure protection, high pressure protection, pure water tank high level protection, exterior operation, operation reposition Reverse osmosis control point: raw water pump, high pressure pump, inflow valve, flush valve, conductivity over limit let valve Collecting input signal: direct current power supply, pull electrical digit, all terminals are isolated . Power voltage: AC 220V±15% 50Hz Power consumption: ≤3W Environment conditions: 1) temperature: 0~50; 2) humidity: ≤85%RH
Measuring range: 0~20μS /cm,0~200μS /cm,0~2000μS /cm (Fixed range which has been set by the manufacturer can not be changed by customers: So please indicate which measure range will be needed before placing an order. The ex-factory standard is 0-200μS /cm without prior indication.) Note: 0~2000μS /cm is suitable for the equipment with conductivity of the outflow water 100~2000μS /cm, with conductivity lower than 100μS /cm, measure range 0~200μS /cm or 0~20μS /cm should be selected. Accuracy: 1.5 levels Controlling output mode: ON single contact relay output Resistivity load impedance: AC 250V/3A Max. Operation pressure of conductance cell: 0~0.5Mpa Medium temperature:5~50 Temperature compensation: automatic temperature with 25 as reference temperature Distance of measuring range: less than 30m (the ex-factory configuration of electrode cable is 5m unless there is a special agreement) Display mode: 3 1/2-digit LED digital display Electrode selected: 1.0cm-1
Outline dimensions: 96×96×130mm (height×width×depth) Meter board hole: 91×91mm (height×width) Installation: Jam-in
RO-2003 Reverse Osmosis Controller
Performance Features
RO-2003 controller combines the
typical operation modes of various
medium and small reverse osmosis
systems, adopts high-performance
computer chip and takes multiple
reliability measures, the technology
is mature and operation reliable; the
control panel visually displays the
operation status of the system by
visual flow chart with LED
indication lamp embedded. RO controller operates in a “five-in-four-out” way.
Main Technical Specifications
Reverse osmosis collect point: five in; no water protection, low pressure protection, high pressure
protection, water level protection, exterior operation.
Reverse osmosis control point: four out; raw water pump, high pressure pump, inflow valve, flush
valve
Collecting input signal: direct current power supply, pull electrical digit, all terminals are isolated .
Power voltage: AC 220V±15% 50Hz
Power consumption: ≤2W
Environment conditions: 1) temperature: 0~50;2) Humidity: ≤85%RH
Controlling output mode: ON single contact relay output
Resistivity load impedance: AC 250V/3A Max.
Outline dimensions: 48×96×100mm(height×width×depth)
Hole dimension: 45×91mm(height×width)
Installation: Jam-in
FLOW METER WLG-8350 Series of Intelligent Network Flow Meter of Turbo Type
Model and Function
Function Model
Pulse input 4-20mA output2 channels OC door output
U disk connection
Communication connection
WLG-8350
WLG-8351
WLG-8352
WLG-8353
Input Instantaneous value range: -9999~9999 radix point position could be set
Cumulation value range: 0~99999999
radix point position could be set
Resolution: 1/20000 Instantaneous value
Input signal type: pulse
Pulse: 0.1~150 KHz
Basic error: Less than ±0.2%F.S
Controlling period of measuring: 0.2
second
Record Record capacity:4MB
Record interval:1second ~59 minutes 59 seconds could be selected. Cycle record or full record
suspends could be chose.
Record time:The computational formula between the record time and record interval :
Record days = (record capacity × record interval )/(24×3600)
72 hours is the shortest time record; 29 years is the longest time record.
Record content: instantaneous value
Alarm
Alarm output: instantaneous flow Hi-lo limited alarm mode and cumulative volume preset output.
OC door output ,voltage less than 30V, current less than 50mA
Transmit
isolated output
4mA~20mA,0mA~10mA,0mA~20mA DC current output, could be selected by setting . The
resistivity load is more than 600Ω. DC current output, select through setting. Load capacity should
larger than 600Ω
Output resolution:1/4000,error less than±0.5% F.S
Communication connection
isolated
RS485 domain communication
Instrument address : 0~99 ,which could be set
Communication rate: 2400、4800、9600、19200 could be selected by setting. It is should be note when
book the meter < 2400
There is a put-off when the meter reply the commend from the computer. The instrument will send the
relevant delay reply of the data when it received the order from the computer:
Be based on the “#” as the order of the rule, the delay reply <500μs ;other delay reply <100ms .
Auxiliary test software, and supply the Technical Support
Power supply of the transmitter
Normal power supply:power supply for the transmitter. The error of Output value is ±5% than the
standard value. The load is > 50mA
Power supply
24V DC,power consumption less than 10VA
PH/ORP METER pH/ORP-8150 Series of Single/Double Channels Intelligent pH and ORP Meter Performance Features: pH/ORP-8150 is a single/double channels pH/ORP meter, the
pH/ORP value of channel 1 or 2 can be displayed by single
channel, double-channel parameters can be also displayed
Simultaneously; Main parameters, temperature and mA
output value could be displayed on the screen synchronously,
the temperature compensation can be set as manual or
automatic mode.
This product is widely used for chemicals, pharmacy,
environmental protection, metallurgy, power factory, paper
making, food and water supply etc.
Main technical specifications: Measure range: pH: 0~14pH;ORP: -1999mV ~ +1999mV Temperature: 0~99.9
Resolution: pH: 0.01pH, mV: 1mV, T: 0.1; Accuracy: pH: ±0.1pH, mV: ±0.5mV, T: ±1 Stability: ≤0.05pH/24h, ≤0.2/24h, ≤0.03mA/24h; Automatic/Manual temperature compensation range:
0~99.9; Automatic three point calibration function; Standard pH solution: 4.01, 6.86, 9.18; Input resistivity resistance: larger than 1.5×1012; The pressure resistance of the electrode: 0~0.6MPa Control range: pH: 0.00~14.00; ORP: -1999~+1999mV Power supply: DC 24V (±4V); Environmental condition: temperature: 0~50;
Humidity: ≤85%RH; Outline dimension: 96×96×103mm (height × width × depth); Slot dimension for installation: 91×91mm (height × width) Installation Jam-in
pH/ORP-8571 pH-meter/oxidation-reduction Potential Controller
Performance Features: pH/ORP-8571 is on-line intelligent industrial pH (ORP) controller. It is suitable for online monitoring of pH/ORP in water treatment, electronic power, chemical industry, pharmacy, environment protection, breeding industry, and so on.
Main Technical Specifications
Display mode: with backlight 128×64 lattice LCD display The range of automatic temperature compensation: 0~99.9 Stability: pH≤0.05pH/24H, ORP≤2mV/24h, T≤0.2/24h ≤0.03mA/24h Identify automatically pH buffer and three point calibration. pH standard liquid: 4.01, 6.86, 9.18. ORP standard liquid: any Input impedance: >1.5×1012 Electrode pressure resistance: 0~0.6 MPa Measuring distance: ≤ 20m(standard configuration for electrode cable:5m).Please use pH transducer for overlong range. Control range: 0~14pH ; -1999mV~+1999 mV
Control output: high limit, low limit double rode ON/OFF double contact point output. Capacity of contact point: AC230V/5A Max; AC 115V/10A Max Communication: RS485 output 4~20mA current output: isolated, transferable, reverse, optional meter/transmitter output. The maximum load impedance: 500 Ω
Max@24V DC Power supply: AC 220V±10% 50Hz Environment conditions: humidity: ≤
85%/RH; no strong electro-magnetic field interference except earth magnetic field Outline dimensions: 96×96×130mm (height×width×depth) Slot dimension for installation: 91×91mm Installation: Jam-in
measurement range 0~14 pH
resolution 0.01 pH
pH
accuracy ± 0.05 pH
measurement range -1999mV~+1999mV
resolution ± 1 mV
ORP
accuracy ± 2 mV
measurement range 0~99.9
resolution 0.1
TEMPERATURE
accuracy ± 0.1
pH/ORP-4571 pH/ORP Controller
Performance Features: pH/ORP-4571 is on-line intelligent industrial pH (ORP) controller. The instrument is suitable for online monitoring of pH/ORP in water treatment, electronic power, chemical industry, pharmacy, environment protection, breeding industry, and so on.
Main technical indexes
Display: LCD. Automatic temperature compensation:
0~99.9ºC. Stability : pH ≤ 0.05PH/24h ; ORP ≤
2mV/24h,T≤0.2/24h,≤0.03mA/24h。 Identify automatically pH buffer and three
point calibration. (Details in item 5-calibration)
pH standard liquid: 4.01, 6.86, 9.18 ORP standard liquid: any Input impedance: >1.5×1012 Electrode pressure resistance: 0~0.6 MPa Measuring distance: ≤ 20m (standard
configuration for electrode cable: 10m). Please use pH transducer for overlong range.
Control range: 0~14pH ; -1999mV~+1999 mV
The mode of control output: high limit, low limit double rode ON/OFF double contact point output.
Capacity of contact point: AC230V/5A Max; AC 115V/10A Max
4~20mA current output: isolated, transferable, reverse, optional
meter/transmitter output. Circular reisitivity: 500ΩMax@24V DC Power supply: AC 220V±10% 50Hz Environment conditions: humidity: ≤
85%/RH; no strong electro-magnetic field interference except earth magnetic field
Control mode: Relay control Load capacity of the relay:AC230V/5A
Max; AC115V/10A Max Displaying:pH/ mV /temperature value Searching: the Hi/Lo limited
measurement range, the error marks Outline dimensions: 96×96×120mm
(height× width ×depth) Instrument panel hole: 91×91mm Installation: Jam-in
measurement range 0~14 pH
resolution 0.01 pH pH
accuracy ±0.1 pH
measurement range -1999mV ~ +1999mV
resolution ±1mV ORP
accuracy ±5mV
measurement range 0~99.9
resolution 0.1 TEMPERATURE
accuracy ±1
pH-4672 PID Intelligent Adjustment Controller
Performance Features: pH-4672 is a kind of precision instrument with microcomputer controlling. The instrument has many Technical features: the green color LCD screen with big character LCD display with backlight; the instrument‘s measurement date could be set through the menu and the data is accurate ; the instrument can anti-jamming ,all digital operation;when the instrument work with the dosing pump, the operation system can be dosing automatically which avoid the mistake of manual dosing.
Transferable, reversible, selectable between active and passive mode, photoelectric isolated 4-20mA output; identify the pH solution , three points calibration; automatic temperature compensation.
Be used in the measurement and PID calibration for the water treatment ﹑power﹑chemistry﹑medicine making﹑environment –protection …
Main Technical Specification Measurement range: pH : 0-14 pH Temperature: 0- 99.9 Resolution : pH:0.01 pH Temperature: 0.1 Accurate: pH: ±0.1 pH Temperature: ±0.1 Display : LCD big character display with backlight Automatic temperature compensation : 0-99.9 Stability: ≤0.05 Ph/24 h ≤ 0.2 /24h ≤ 0.03Ma /24h Automatic Three-point adjustment Standard Ph solution :4.01 6.86 9.18 Input resistivity load: more than 1.5×1012 Control range :pH 0-14 The fastest rate of Frequency output : 400 pulse/minute ,used in driving the metering
pump Power supply: :AC 220V ± 10 % 50 HZ Environment conditions: temperature: 0-50 humidity: ≤85%/RH; Outline dimensions: 96×96×130mm (height×width×depth) instrument panel hole: 91×91mm(height×depth) Installation mode: jam-in
pH/ORP-6241 pH/ORP Meter
Performance Features: pH/ORP-6241 controller is an industrial on-line analysis and monitoring instrument, with 51 series Single Chip Microcomputer (SCM) and CMOS interface chip adopted. It’s with various software functions, and has such features as easy installation and operation, strong anti-interference capability and little amount of maintenance work. High-accuracy temperature compensation is also adopted. The pH -6241 is suitable for environmental protection and on-line measurement; the ORP-6241 is widely used in OPR measurement of Water treatment, electronics industry, pharmacy, chemical, environment-protection… Main Technical Specifications pH measurement range : 0~14 pH ORP measurement range : -1000~+1000mV pH resolution: 0.01 pH ORP resolution: 1mV pH accuracy: 0.1 pH ORP accuracy ±1mV Electrode pressure resistance: 0~0.6Mpa Power supply: AC 220V±10% 50Hz Distance limit of measurement: ≤40m (standard configuration for electrode cable: 10m). Please use pH transducer for overlong range. Contact capacity: 3A(240V AC) Temperature of measured solution: 0~80 Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except earth magnetic field Manual temperature compensation: 0~99 Stability: -1000-1000mV In-put Impedance: ≥ 1×1012Ω Output Signal: Isolated and transferable 4~20 mA current output. The maximum load impedance: 500ΩMax@24V DC Control output mode: ON single contact relay output Load capacity of the relay:AC230V/5A Max; AC115V/10A Max Outline dimensions: 96×96×130mm (height×width×depth) Slot dimension for installation: 91×91mm (height × width) Installation: Jam-in
pH-650 pH Controller Performance Features: pH-650 controller is an industrial on-line analysis and monitoring instrument. The instrument is suitable for online monitoring of pH/ORP in water treatment, electronic power, chemical industry, pharmacy, environment protection, breeding industry, and so on.
Main Technical Specifications pH measurement range: 0~14 pH Resolution: 0.01 pH Accuracy : ±0.1 pH Electrode pressure resistance: 0~0.6Mpa Power supply: AC 220V±10% 50Hz Distance limit of measurement: ≤20m (standard configuration for electrode cable: 10m). Please use pH transmitter for overlong range. Contact capacity: 3A(220V AC) Temperature of measured solution: 0~80 Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except earth magnetic field Manual temperature compensation: 0~99 Output signal : non-isolated 4~20 mA Manual compensation : 0~99 Display: 3.5 bit LCD With resistive load:300ΩMax@24V DC Control output: ON single contact double relays output Relay load capacity:AC 230V/5A Max; AC115V/ 10A Max Auxiliary: Plastic-shell double combination electrode. Outline dimensions: 48×96×100mm (height×width×depth) Slot dimension for installation : 45×91mm Installation mode: Jam-in
ORP-651 Oxidation-reduction Potential controller
Performance Features: We really appreciate your selection of
ORP-651 controller. It is an industrial
on-line analysis and monitoring instrument.
It’s with various software functions, and has
such features as easy installation and
operation, strong anti-interference capability
and little amount of maintenance work.
Main Technical Specifications ORP measurement range: ±1000mV
Resolution: ±1mV
Accuracy: ±0.1 mV
Electrode pressure resistance: 0~0.6Mpa
Power supply: AC 220V±10% 50Hz
Distance limit of measurement: ≤40m (standard configuration for electrode cable: 10m). Please use
ORP transmitter for overlong range.
Temperature of measured solution: 0~80
Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except
earth magnetic field
Display: 3.5 bit LCD
Signal: Non-isolated 4~20mA current.
With resistive load:300ΩMax@24V DC
Control output Mode: ON/OFF double relays output
Relay load capacity:AC 230V/5A Max; AC115V/ 7A Max
Auxiliary electrode: ORP Electrode.
Power supply: AC220V±10% 50HZ
Outline dimensions: 48×96×100mm (height×width×depth)
Slot dimension for installation : 45×91mm (height × width)
Installation: Jam-in
pH/ORP-542 pH /ORP Meter
Performance Features: pH/ORP-542 meter is an industrial on-line analysis and monitoring instrument. It’s with various software functions, and has such features as easy installation and operation, strong anti-interference capability and little amount of maintenance work. High-accuracy temperature compensation and pH operation compensation is also adopted.
Functions pH or ORP can be selected through menu. Back ground LCD digital display. Direct reading and accurate control with Micro chip for data processing Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument. 4~20mA current output for long-distance transmitting. It can optionally display pH mV value. Strong anti-interference capability and automatically reset in case of power off.
Main Technical Specifications pH measurement range :0~14 pH ORP measurement range :0~±1000mV Resolution :0.01 pH, ±1mV Accuracy :±0.05 pH, ±1mV Electrode pressure resistance: 0~0.6Mpa Power supply: AC 220V±10% 50Hz Distance limit of measurement: ≤20m (standard configuration for electrode cable 10m). Please use pH /ORP transmitter for overlong range. Temperature of measured solution: 0~80 Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except earth magnetic field; no obvious acid or alkali mirage around . Manual temperature compensation: 0~99 Output signal : non-isolated 4~20 mA Load impedance:300Ω Outline dimensions: 48×96×100mm (height×width×depth) Instrument panel hole: 45×91mm Installation: Jam-in
pH/ORP-540 pH/ORP Meter Performance Features: pH/ORP-540 meter is an industrial on-line analysis and monitoring instrument. It’s with various software functions, and has such features as easy installation and operation, strong anti-interference capability and little amount of maintenance work. High-accuracy temperature compensation and pH operation compensation is also adopted. Functions
pH or ORP can be selected through menu.
Back ground LCD digital display. Direct reading and accurate control with Micro chip for data processing Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument. It can optionally display pH mV value. Strong anti-interference capability and automatically reset in case of power off.
Main Technical Specifications pH measurement range : 0~14 pH ORP measurement range: 0~±1000mV Resolution : 0.01 pH, ±1mV Accuracy: ±0.05 pH, ±1mV Electrode pressure resistance: 0~0.6Mpa Power supply: AC 220V±10% 50Hz Distance limit of measurement: ≤20m (standard configuration for electrode cable 10m). Please use pH /ORP transmitter for overlong range. Temperature of measured solution: 0~80 Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except earth magnetic field; no obvious acid or alkali mirage around . Manual temperature compensation: 0~99 Outline dimensions: 48×96×100mm (height×width×depth) Display: 3.5 bit LCD Auxiliary: Plastic shell double combination electrode Output signal: pH /ORP -540, It can optionally display pH mV value Instrument panel hole: 45×91mm Installation: Jam-in
TRANSMITTER pHT-5431 pH Transmitter
Performance Features: Welcome to use pH-5431 isolated pH transmitter. It apply to pH signal collect of long distance and pH signal output , the direct output standard current signal is 4~20mA. It’s with various software functions, and has such features as easy installation and operation, strong
anti-interference capability and little amount of maintenance work. High-accuracy temperature compensation and pH operation compensation is also adopted.
Functions and Main Technical Specifications Functions
Back ground LCD digital display. Direct reading and accurate control with
Micro chip for data processing Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument. 4~20 mA current output is isolate, transferable, reversal, and can switch output mode of the
meter and transmitter. It has functions of menu input and operation error compensation. It can optionally display pH, mV value. It has strong anti-interference and automatically breaks away the power. It has the proof –water panel and operation keyboard.
Main Technical Specifications pH measurement range :0~14 pH Resolution: 0.01 pH Accuracy : ±0.1 pH Electrode pressure resistance: 0~0.6Mpa Display: 3.5 bit LCD digit display Distance limit of electrode cable: ≤20m (standard configuration for electrode cable: 10m). The maximum load impedance: 500Ω Max @ DC24V Temperature of measured solution: 0~99 Manual temperature compensation: 0~99 Environment conditions: temperature:0~50, humidity: ≤85%/RH; no strong electro-magnetic field interference except earth magnetic field Power supply : DC 24V±10% mA output: isolate, transferable, reversal 4~20 mA current, the switch output mode of meter and transmitter. Outline dimensions: 130×70×50mm (height×width×depth) Installation: Pipe or plane installation
CT-121Conductivity Transmitter
Performance Features: Conductivity Transmitter CT-121 is designed with one-piece
and hermetic, as a PLC controller and primary instrument of
monitor and controller, the transmitter has characters of
water-proof, damp-proof and installed directly at scene,
anti-interference, easy installation and good weatherability
etc.
Specifications Sealed, water-proof, one-piece design, fix settings
included.
Double line transmission, non-polarity
connection(automatic identification of the polarity)
Surface SMT technology
4~20mA standard current signal;
DC24V power supply
316L/Ti metal electrode
Automatic temperature compensation
Technical parameters:
Measure range: 0~20;0~200;0~2000μS/cm
Accuracy: ±1.5%(FS) of the readings
Shell: epitheca: ASA; Lower casing: nylon
Electrode: electrode:316L
Weight: about 200g
Operation environment: 0~50
Storage temperature: -15~60
Relative humidity: 0~100%RH
Current output: 4~20mA, in series
Power: DC 24V±5%
Maximum circle resistance: 24V@600Ω
Accuracy/precision: ±0.3mA@25
Installation: pipe installation
DBY-5100/5200 Conductivity Transmitter
Performance features
5100 is an integration mode conductivity transmitter.
5200 is a fission mode conductivity transmitter. They can
meet long distance measurement of water solution
conductivity in the industrial processes. The all sealed
shell design meet the IP65 defending technology grade ,
can adapt to the wet environment .The any transferable
4~20mA isolated current sgnal can realize the operation
mode of meter/transmitter by change the connection
mode.
Technical Specification
Conductivity measurement range:
Electrode constant 0.1cm-1 : 0~20 μS/cm, 0~200 μS/cm
(optional)
Electrode constant 1.0cm-1 : 0~20 μS/cm, 0~200 μ S/cm 0~2000 μS/cm (optional)
Electrode constant 10.0cm-1 : 0~200 μS/cm, 0~2000 μS/cm 0~20 mS/cm (optional)
Temperature measurement range :0~50
Accuracy:1.5%(FS)
Stability: ±2×10-3 (FS)/24h
Signal output : isolate , transferable 4~20mA current ,
the optional output mode of meter/transmitter
Power supply: DC 24V±10%
Temperature of measured solution: 5~50
Defending types :IP65 defending grade
The max circulative resistance : DC 24V@600Ω
Display mode : Conductivity : 3.5bit LCD digital
display , Temperature : 3bit digital display
Outline dimensions: 130×70×50mm (height×width×depth)
Installation mode: pipeline installation(5100), plane installation(5200).
DBY-5600 Explosion-proof Conductivity Transmitter
Performance features
The conductivity transmitter can meet Inflammable,
explosive gas ‘s industrial environment design. With the
transferable 4~20mA isolated current signals, can change
the connection mode which realize meter /transmitter’s
operation mode .
It uses the micro processor to control the intelligent
operation. It’s with various software functions, and has
such features as choosing electrode mode, switch
measurement range, constant calibration, and
temperature compensation.
Technical Specification:
Conductivity measurement range:
Electrode constant 0.1cm-1 : 0~20 μS/cm, 0~200 μS/cm (optional)
Electrode constant 1.0cm-1 : 0~20 μS/cm, 0~200 μ S/cm ,0~2000 μS/cm (optional)
Electrode constant 10cm-1 : 0~200 μS/cm, 0~2000 μS/cm, 0~20 mS/cm (optional)
Accuracy :1.5%(FS)
Stability: ±2×10-3 (FS)/24h
Power supply: DC 24V±10%
Temperature of measured solution: 5~50
Environment conditions: Temperature :5~50
humidity:≤85%RH;
The max circulative resistance : DC 24V@600Ω
Display mode : Conductivity 3.5bit LED digital display ,
The signal output: Isolated, transferable current 4~20mA , optional output mode of meter and
transmitter.
Defending type : Exd ⅡcCT6 defending grade
Installation: jam-in or fission
HL-360 Loop Meter
Performance and applications: The instrument can display and control the industrial process conductivity transmitter, resistivity
transmitter and pH transmitter; it has
functions of conductivity, resistivity, pH
value displaying, over limit alarm,
control output etc. This meter also can
be used as the second instrument for
displaying conductivity, resistivity, and
pH value. Double line mode 4-20mA
standard current transfer, and advanced
anti-interference capability were
adopted.
This instrument meets the needs of long-distance measure, display and control operation between the
control room and the industrial place.
Main technical specifications: Micro CMOS chip for data processing read directly and control accurately, automatic replacement
when power off.
Automatic and freely calibration of two point ratio and selectable relay control output of high/low
limit alarm.
Display mode: 3½ bit backlight LCD digital display
Display(selectable): μS/cm、mS/cm、MΩcm、pH、mA value.
Input signal: 4~20mA
Conductivity measure range: 0~20μS/cm, 0~200μS/cm, 0~2000μS/cm;
0~20 mS/cm, 0~200mS/cm, 0~2000mS/cm
Resistivity measure range: 0~20.00 MΩcm
pH measure range: 0~14pH
mA value measure range: 0~19.99mA
Accuracy: ±1.0 %( FS)
Stability: ±2×10 -3(FS)/24h
Contact capacity: 5A/250V AC (for resistive load)
Environment Conditions: temperature: 0~50, relative humidity:≤85%/RH
Power supply: AC220V±10% 50HZ
Dimensions: 48×96×100mm (height ×width ×depth)
Slot dimensions for installation: 45×91mm (high × width) Installation: Jam-in
ELECTRODE DCS1121—1.0cm-1 Conductivity Electrode
Usage: Conductivity measurement of weak electrolyte, include industrial water,
cooling water, pure water etc.
Features: ABS fast installation, screw thread, Pipeline installation and side
installation on the tank
Specification: Electrode constant: 1.0 cm-1
Performance:
Electrode type: two sensor system.
Material: engineering plastic framework, stainless steel underlay with platinum
black
Temperature compensation components: NTC 10KΩ
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCG1121-1.0~0.01cm-1 Electrode
Usage: Conductivity measurement of industrial water, cooling water,
pure water, high-pure water, ultra water etc.
Performance:
Electrode type: Two sensor system
Material: 316 L Stain Steel
Temperature compensation components: NTC 10KΩor Pt100/1000
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50
Cable Length: 5 meters long Ex-factory or made by requirement
Features:
316 L Stain Steel, corrosion proof, long-time using
Specification:
Electrode constant: 1.0 、0.1、0.05 、0.01cm-1
DCT1121-0.1~0.01cm-1 Electrode Usage: Conductivity measurement of pure water, high-pure water, ultra
water etc.
Features: titanium metal, corrosion resistance, anti electricmagnetic
field interference, good hydration
Specification: Electrode constant: 0.1、0.01cm-1
Performance:
Electrode type: two sensor system
Material: titanium metal
Temperature compensation components: NTC 10K or Pt100/1000
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCT3121-1.0~0.01cm-1 Electrode
Usage: Conductivity measurement of industrial water, cooling water, pure
water, high-pure water, ultra water etc.
Electrode type: 316 L Stain Steel, corrosion resistance, long useful life
Specification: Electrode constant: 1.0,0.1,0.05 0.01cm-1
Performance:
Electrode type: two sensor system
Material: 316 L Stain Steel
Temperature compensation components: NTC 10K or Pt100/1000
Connection: 1/2″NPT (Stain steel fast-installation joint)
Pressure: 0.5 MPa
Medium temperature: 0-50
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCG2132-0.1~0.01cm-1 Electrode
Usage: Conductivity measurement of steam condensation water, bottom
water of boiler
Feature: 316 L Stain Steel, corrosion resistance, High temperature, and
high-pressure
Specification: Electrode constant: 0.1,0.01cm-1
Performance:
Electrode type: two sensor system
Material: 316 L Stain Steel
Temperature compensation components: NTC 10K or Pt100/1000
Connection: 1/2″NPT, Stain steel cube.
Pressure: 0.5 MPa
Medium temperature: 60~120
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCS0120-1.0cm-1 Electrode
Usage: Conductivity measurement of weak electrolyte, include industrial
water, cooling water, tap water, pure water etc.
Features: solid shell, legerity, easy to carry.
Specification: Electrode constant: 1.0 cm-1
Performance:
Electrode mode: Two sensor system
Material: Plastic shell, stainless steel underlay with platinum black
Temperature compensation components: NTC 10KΩ
Medium temperature: 0-50
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCG-7121 Microminiature Integration Conductivity Sensor for Ultra Pure water Usage Be widely used in the Power House, Chemistry, Medicine Making, Environment Protection, Paper Making, Food, Water Supply…
Technical Features Design in the integration Made by 316L S.S Effective measurement space, no backwater or dead angle,
improve the measure accuracy. Smaller size and convenient connection.
Main Technical Specification Electrode constant : 0.01 cm -1 , 0.05 cm -1 Electrode mode: temperature compensation electrode. Material: 316 L SS Temperature compensation component:NTC or Pt Pressure : 0.6 MPa tangential : 0-50 Coil out:outgoing cable directly and then screw on by cap. Cable length:0.5m Ex-factory.
DCS-4321 Conductivity Sensor
Usage
Used in the seawater desalination, bitter, acid solution, aqueous
alkali …
Main Technical specification:
Material: 316 L Stain Steel, Teflon, corrosion resistance, long useful life
Specification: Electrode Constant: 10.0 cm-1
Electrode mode: temperature compensation electrode
Temperature compensation component:NTC 10 KΩ or Pt100/1000
Connection: 3/4″ NPT.
Pressure: 0.5 MPa
Medium temperature: 0-50
Coil out:outgoing cable directly and then screw on by cap.
Cable Length: 5 meters long Ex-factory or made by requirement.
WOL-0321-5 Sensor of Turbo Flow Usage
Petroleum, chemistry, metallurgy, water supply, paper making, industry
cooling system, water treatment system…
Technical parameter:
Material: ABS plastic
Measurement: tangential measurement
Medium temperature: 0-60
Storage temperature:-20 ~80
Pressure: 0.6 MPa
Power supply: 12 V DC
Pulse output: ≥ 8V
Transmit distance: ≥ 1000 M
Pipe diameter: DN-25 ~ DN 200
Pipe material: plastic, metal, glass fiber reinforced plastic, cement.
Environment: There is no strong alternative magnetic field around the
electrode.
Medium requirement: Install the Y filter when there is some granule exists in the pipeline.
PC202 Plastic pH Combination Electrode
Range:0-14pH Temperature:0-100
Pressure:0.6MPa Process connection:Top & bottom 3/4 inch NPT, threads
Material:PPS Cable connection:connected by low noise cable directly
Characteristics: Adopt the most advanced solid electrolyte and Tetrafluoroethlene liquid junction which resist to be
blocked and maintenance conveniently.
Long distance diffusion path of reference solution extended the useful life under the harsh conditions.
Wider temperature range can be used in explosion-protection area.
New design of glass bulb, increase surface area of it and prevent inner buffer solution from interfere of
air bulb to gain reliable measurement.
Adopt PPS body, top/bottom 3/4 inch threads that easy to be installed and no housing needed, saving
the cost of installation.
Use high quality low noise cable, the distance of output signals is longer than 20 meters without
disturbance.
Application area: Medicine, chlorine-alkali chemical-engineering, paint & dye, paper making, intermediate, fertilizer,
starch, environment-protection… ; temperature fluctuation less than 10.
PCORP Plastic ORP Combination Electrode
Measure range:±2000mV Temperature range:0-100
Pressure:0.6MP Installation dimension:Top & bottom 3/4 inch NPT, threads
Materials:PPS Connection:low noise cable directly
Characteristics: Adopt the most advanced solid electrolyte and Tetrafluoroethlene liquid junction which resist to be
blocked and maintenance conveniently.
Long distance diffusion path of reference solution extended the useful life under the harsh conditions.
Wider temperature range can be used in explosion-protection area.
Adopt PPS body, top/bottom 3/4 inch threads that easy to be installed and no housing needed, saving
the cost of installation.
Use high quality low noise cable, the distance of output signals is longer than 20 meters without
disturbance.
Application area:
Be used for the ORP testing of Medicine, chlorine-alkali chemical-engineering, paint & dye, paper
making, intermediate, fertilizer, starch, environment-protection…
G102 pH Combination Electrode
Measure range:2-12pH Temperature range:0-60
Pressure:0.3MP Dimension:diameter12×120mm
Material: Glass Connection:AS7、PG13.5 threads international standard
Characteristics: Apply big area low impedance sensitive membrane bulb, suitable for pure water application.
Apply gel type electrolyte, solid bridge electrolyte. Electrophoresis cell consists of two different kinds of
gel electrolytes, make sure longer working life of the electrode and reliable readings.
International standard connection, can replace imported electrodes directly.
Application area: Water treatment, pure water industry.
——CREATE
Your reliable business partner!