160
Manual CPV pneumatics CPV valve terminal Type CPV...-VI Manual 165200 en 1609i [8064940] Compact performance

Compact performanceSPC200 Smart Positioning Controller, User manual type P.BE-SPC200-... Installation, commissioning and diagnosis with SPC200; standard components and modules WinPISA

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • ManualCPV pneumatics

    CPV valve terminalType CPV...-VI

    Manual165200en 1609i[8064940]

    Compact performance

  • Contents and general instructions

    I

    Original de. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Edition en 1609i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Designation P.BE-CPV-EN. . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Order no. 165200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    © (Festo SE & Co. KG, Postfach, 73726 Esslingen, 2016) Internet: http://www.festo.comE-Mail: [email protected]

    The reproduction of this document and disclosure to third parties and the utilisation or communication of its contents without explicit authorization is prohibited. Offenders will be held liable for compensation of damages. All rights reserved, in particular the right to carry out patent, utility model or ornamental design registrations.

    Festo P.BE-CPV-EN en 1609i

  • Contents and general instructions

    II Festo P.BE-CPV-EN en 1609i

    AS-Interface®, CANopen®, DeviceNet®, IP-Link®, CC-Link®, Interbus®, PROFIBUS-DP®,SUCOnet K® and Simatic® are registered trademarks of the respective trademark ownersin certain countries.

  • Contents and general instructions

    IIIFesto P.BE-CPV-EN en 1609i

    Contents

    Designated use VII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Areas of application and approval by authorities VIII. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Target group VIII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Service VIII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Notes on the use of this manual IX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Important user instructions XII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    List of abbreviations XIV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1. System summary 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.1 Description of variants 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2 Description of components 1-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2. Fitting 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.1 General instructions on fitting and dismantling 2-3. . . . . . . . . . . . . . . . . . . . . . .

    2.2 CPV valve terminal with individual tubing 2-3. . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.1 Wall mounting 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.2 Hat rail mounting 2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.3 Fitting onto a stand 2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.4 Fitting into a control cabinet 2-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.5 Fitting the CPV valve terminal to the SIMATIC ET200X 2-12. . . . . . . . . .

    2.2.6 Fitting the CPV valve terminal onto SIMATIC ET200pro 2-15. . . . . . . . . .

    2.3 CPV valve terminal with pneumatic multipin 2-16. . . . . . . . . . . . . . . . . . . . . . . . .

    2.3.1 Fitting the pneumatic multipin 2-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.3.2 Fitting the CPV valve terminal to the pneumatic multipin 2-20. . . . . . . .

    2.4 Fitting the valve extensions 2-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.5 Fitting the identifier support 2-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.6 Fitting covers on the manual overrides 2-24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Contents and general instructions

    IV Festo P.BE-CPV-EN en 1609i

    3. Installation 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.1 Preparing the compressed air 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.1.1 Operation with non-lubricated compressed air 3-3. . . . . . . . . . . . . . . .

    3.1.2 Operation with lubricated compressed air 3-4. . . . . . . . . . . . . . . . . . . .

    3.2 General instructions on installation 3-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.3 Laying the tubing 3-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.4 Connecting the CPV valve terminal 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.4.1 Pilot air supply 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.4.2 Connecting the supply and work lines 3-12. . . . . . . . . . . . . . . . . . . . . . .

    3.4.3 Connecting the electric cables 3-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4. Commissioning 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.1 General instructions 4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.2 Testing the valves 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.2.1 Checking the valve functions 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.2.2 Checking the valve-actuator combination 4-9. . . . . . . . . . . . . . . . . . . .

    4.3 Troubleshooting 4-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5. Maintenance and conversion 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5.1 General precautionary measures 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5.2 Cleaning/replacing the large surface-mounted silencer 5-4. . . . . . . . . . . . . . . .

    5.3 Fitting/removing CPV valve terminal components 5-5. . . . . . . . . . . . . . . . . . . . .

    5.3.1 Removing components from valve locations 5-6. . . . . . . . . . . . . . . . . .

    5.3.2 Fitting components in valve locations 5-10. . . . . . . . . . . . . . . . . . . . . . .

    5.4 Conversion from non-locking to locking manual override 5-15. . . . . . . . . . . . . . .

    5.5 Converting the end plates 5-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5.6 Conversion to internal or external pilot air 5-18. . . . . . . . . . . . . . . . . . . . . . . . . . .

    5.7 Individual/Central tubing conversion 5-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5.8 Conversion of the CPV valve terminal to two pressure zones 5-19. . . . . . . . . . . .

    5.9 Converting the CPV valve terminal to a variant with different electrical connections 5-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Contents and general instructions

    VFesto P.BE-CPV-EN en 1609i

    A. Technical appendix A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    A.1 Technical specifications A-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    A.2 Accessories A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    B. Summary of components B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    B.1 Overview of valve sub-bases and vacuum generator plates B-3. . . . . . . . . . . . .

    B.2 Overview of end plates B-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    C. Index C-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Contents and general instructions

    VI Festo P.BE-CPV-EN en 1609i

  • Contents and general instructions

    VIIFesto P.BE-CPV-EN en 1609i

    Designated use

    The CPV valve terminals described in this manual are intended for fitting into a machine or automated system. Theuser must at all times observe the safety regulations specified in this manual as well as the instructions concerning thedesignated use of the relevant CPV valve terminal. CPV valveterminals may only be used as follows:

    – as designated in industrial applications.

    – without any modifications by the user. Only the conversions or modifications described in thedocumentation supplied with the product are permitted.

    – in perfect technical condition.

    When used together with commercially available components, such as actuators, the specified limits for pressures,temperatures, electrical data, torques etc. must be observed.National and local safety regulations must also be observed.

  • Contents and general instructions

    VIII Festo P.BE-CPV-EN en 1609i

    Areas of application and approval by authorities

    Standards and test values, which the product must observeand fulfil, can be found in the section “Technical specifications”. The product-relevant EU directive can be found in theconformity declaration.

    Certain configurations of the product have been approved bythe Underwriters Laboratories Inc. (UL) for the USA andCanada. These configurations are marked as follows:

    NoteObserve the following if the UL requirements are to becomplied with in your application:

    � Rules for observing the UL certification can be found inthe separate UL-specific documentation. The relevanttechnical specifications listed there also apply here.

    � The technical specifications in this documentation mayshow different values.

    Target group

    This manual is intended exclusively for technicians trained incontrol and automation technology who have experience infitting, installing, commissioning, servicing and convertingpneumatic components.

    Service

    Please consult your local Festo service centre if you have anytechnical problems.

  • Contents and general instructions

    IXFesto P.BE-CPV-EN en 1609i

    Notes on the use of this manual

    This manual contains specific information on fitting, installing,commissioning, servicing and converting the CPV valve terminal. This manual describes only the pneumatic componentsand refers to the CPV valve terminal variants listed in thetable below.

    Variants of the CPV valve terminal type CPV...-VI...

    with IC connection

    Information on theelectric/electroniccomponents:in this manual

    with MP connection

    Information on theelectric/electroniccomponents:see leaflet with product

    with CPI/CP connection

    Information on theelectric/electroniccomponents:See manual “CP system,installation andcommissioning”

    ÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒ

    with AS-Interfaceconnection

    Information on theelectric/electroniccomponents:see leaflet with product

    ÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒÒ

    with CP direct connection

    Information on theelectric/electroniccomponents:see manual “CPV valveterminal with directconnection” for therelevant field bus.

    with ET200X/ET200profrom Siemens

    Information on theelectrical/electroniccomponents:see corresponding manualfrom Siemens AG

    Tab. 0/1: Variants of the CPV valve terminal

  • Contents and general instructions

    X Festo P.BE-CPV-EN en 1609i

    From the colour of the electrical sub-base (CP = black sub-base, CPI = grey sub-base), you can ascertain whether youhave a CPV valve terminal with normal functions (CP) or onewith extended functions (CPI).

    Information on further CP modules, as well as basic information which must be observed in conjunction with the higher-order system, can be found in the manuals for the relevantmodules/systems.

    The table below gives an overview.

    Type Title Manuals

    ManualElectronics

    “CP system, installationand commissioning”type P.BE-CPSYS-...

    General basic information on fitting, installingand commissioning CP systems and on theirmethod of operation.

    “CP field bus node,programming anddiagnosis”type P.BE-CP-FB...or�P.BE-VIFB...-10...

    Special information on commissioning,programming and diagnosing related to thenode used.

    “CP modules,electronics”type P.BE-CPEA-...

    Information on fitting, installing andcommissioning CP I/O modules.

    “CPX-CP interface”type P.BE-CPX-CP-...

    Instructions on fitting, installing, commissioningand diagnosing CP systems with the CP interfacetype CPX-CP-4-FB

    ManualPneumatics

    “CPV valve terminal,pneumatics” or“CPA�valve terminal,pneumatics”type P.BE-CPV-...or�P.BE-CPA-...

    Information on fitting, installing andcommissioning CPA or CPV valve terminals

    Tab. 0/2: Manuals on the CP system

  • Contents and general instructions

    XIFesto P.BE-CPV-EN en 1609i

    Type Title Manuals

    ManualElectronics

    SPC200 SmartPositioning Controller,User manual type P.BE-SPC200-...

    Installation, commissioning and diagnosis withSPC200; standard components and modules

    WinPISA manual type P.SW-WIN-PISA-...

    Functions of the WinPISA software package

    Tab. 0/3: Manuals on the SPC200

    NoteThe CPV valve terminals can also be operated with furtherFesto products, e.g. the SPC200.

    Further information see: } www.festo.com

  • Contents and general instructions

    XII Festo P.BE-CPV-EN en 1609i

    Important user instructions

    Danger categories

    This manual contains instructions on the possible dangerswhich may occur if the product is not used correctly. Theseinstructions are marked (Warning, Caution, etc.), printed on ashaded background and marked additionally with a pictogram. A distinction is made between the following dangerwarnings:

    WarningThis means that failure to observe this instruction mayresult in serious personal injury or damage to property.

    CautionThis means that failure to observe this instruction mayresult in personal injury or damage to property.

    NoteThis means that failure to observe this instruction mayresult in damage to property.

    The following pictogram marks passages in the text whichdescribe activities with electrostatically sensitive components.

    Electrostatically sensitive components may be damaged ifthey are not handled correctly.

  • Contents and general instructions

    XIIIFesto P.BE-CPV-EN en 1609i

    Marking special information

    The following pictograms mark passages in the textcontaining special information.

    Pictograms

    Information:Recommendations, tips and references to other sources ofinformation.

    Accessories:Information on necessary or sensible accessories for theFesto product.

    Antipollution:Information on environment-friendly use of Festo products.

    Text markings

    � The bullet indicates activities which may be carried out inany order.

    1. Figures denote activities which must be carried out in thenumerical order specified.

    – Hyphens indicate general activities.

  • Contents and general instructions

    XIV Festo P.BE-CPV-EN en 1609i

    List of abbreviations

    The following product-specific terms and abbreviations areused in this manual:

    Term Meaning

    5/3G valve extension Module with two unlockable check valves. With the CPV10/14 valveterminals, the valve function “5/3-way in mid-position closed” isimplemented with this module and the valve sub-base Ident. code C.

    AS-Interface Actuator Sensor Interface

    AS-Interface connection CPV valve terminal variant with serial connections which enables theCPV�valve terminal to be connected to the AS-Interface bus

    Blanking plate Plate without valve function, for reserving empty valve locations

    Components Common term for sub-bases, end plates, relay plates, blanking plates,separator plates, valve sub-bases, valve extensions, vacuum generatorplates and pneumatic multipin

    Connecting the tubing Connecting the supply lines (tubing) to the CPV valve terminal

    CP Compact Performance

    CP cable Special cable for coupling the various CP modules

    CP connection CPV valve terminal variant with plug and socket which enables theCPV�valve terminal to be connected to a field bus node and furtherCP�modules

    CP modules Common term for the various modules which can be incorporated in aCP�system

    CP system Complete system consisting of CP field bus node and CP modules

    CPI connection Socket or plug on the CPI modules which allows the modules to beconnected using the CPI or CP cable

    CPV10CPV14CPV18

    Size designations of the CPV valve terminals:– with micro valve sub-bases (CPV10)– with mini valve sub-bases (CPV14)– with midi valve sub-bases (CPV18)

    CPV valve terminal CPV valve terminal (type 10) fir field bus systems or with IC, MP, DI orAS-Interface connections

  • Contents and general instructions

    XVFesto P.BE-CPV-EN en 1609i

    Term Meaning

    DI connection CPV valve terminal variant with plug and socket which can be connecteddirectly with the field bus and with further CP modules, depending on type

    Electrical sub-base Sub-base with multipin, AS-Interface, DI or CPI/CP connections

    End plate Cover plate at the left and right-hand ends of the CPV valve terminal withchannels or connections for supplying the valves with compressed airand for conducting the exhaust air

    I/O Input/output modules

    IC connection (individual connection)

    CPV valve terminal variant on which every valve solenoid coil can beconnected individually with a special CP cable

    Manual override Manual override

    MP connection (multipin connection)

    CPV valve terminal variant with sub-D plug via which all valve solenoidcoils are connected centrally

    Pneumatic multipin Plate for central tubing connections on the valve terminal (supply air,exhaust air and work air connections)

    Pneumatic multipleconnector plate

    Plate for central tubing connections of the valve terminal on the wall of acontrol cabinet (connections for supply air, exhaust air and work air)

    Relay plate Plate with relay coils for actuating two electrically-isolated outputs

    Separator plate Plate for dividing the valve terminal into two/four pressure zones

    Vacuum generator plate Plate with vacuum generator (with or without reject pulse)

    Valve manifold Basic unit with valve sub-base, vacuum generator plate, separator,blanking, relay and end plates

    Valve sub-base Sub-base with single-solenoid or double-solenoid valves

    Tab. 0/4: Product-specific terms and abbreviations

  • Contents and general instructions

    XVI Festo P.BE-CPV-EN en 1609i

  • System summary

    1-1Festo P.BE-CPV-EN en 1609i

    Chapter 1

    System summary

  • 1. System summary

    1-2 Festo P.BE-CPV-EN en 1609i

    Contents

    1. System summary 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.1 Description of variants 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2 Description of components 1-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 1. System summary

    1-3Festo P.BE-CPV-EN en 1609i

    1.1 Description of variants

    Festo assists you in solving your automation task at the machine level with valve terminals. The modular structure of theCP system enables you to incorporate the CP valve terminalsand I/O modules optimally in your machine or system.

    Due to its compact structure the CP valve terminal can bemounted close to the actuators to be controlled. This meansthat short compressed air supply lines can be used. Systemlosses will therefore be minimized and the times required forpressurizing and exhausting the compressed air tubing willbe reduced. This is made possible by the use of very compactvalves with sufficient flow, thereby helping to reduce costs.

  • 1. System summary

    1-4 Festo P.BE-CPV-EN en 1609i

    CPV valve terminalvariants

    The CPV valve terminals are available with the followingtypes of electrical connections:

    IC connection CP direct connection MP connection

    AS-Interfaceconnection

    CPI/CP connection

    Fig. 1/1: Variants of the CPV valve terminal

    CPV valve terminal withIC�connection

    The CPV valve terminal with IC connection is available with2�to 8 valve sub-bases (also in odd gradation). The electricalconnection is made individually on each valve solenoid coil.

    CPV valve terminal withMP connection

    This CPV valve terminal is available with 4, 6 or 8 valve sub-bases. The valve solenoid coils are connected electrically viathe multipin connection.

    CPV valve terminal withCPI/CP connection

    The CPV valve terminal with CPI/CP connection is availablewith 4, 6 or 8 valve sub-bases. The connection to the higher-order field bus node is made via special ready-to-use CPcables.

  • 1. System summary

    1-5Festo P.BE-CPV-EN en 1609i

    CPV valve terminal withDI�connection

    The CPV valve terminals with direct connection are availablefor the following field bus systems in the sizesCPV10/14/18:

    – CANopen

    – DeviceNet

    – IP link (CPV10/14)

    – CC link

    – Interbus

    – PROFIBUS-DP, Festo field bus, ABB CS 31, Klöckner-Moeller SUCOnet K

    These valve terminals can be connected directly to therelevant field bus. These CPV valve terminals are fitted with4�or 8 valve sub-bases depending on the field bus system.

    CPV valve terminal withCT200X/CT200pro connection

    This CPV valve terminal is an adaptation of the CPV valveterminal to the input/output module ET200X/ET200pro fromSiemens:

    – 8 valve slices/16 solenoid coils

    – Size CPV10 and CPV14

  • 1. System summary

    1-6 Festo P.BE-CPV-EN en 1609i

    CPV valve terminal withAS-Interface�connection

    This CPV valve terminal is connected to the AS-Interface busvia special AS-Interface cables. It is available with 2, 4 or8�valve sub-bases depending on the variant and with fourdifferent kinds of electrical connections:

    – with additional supply connection for implementing anemergency stop function

    – with additional supply connection and 4 or 8 inputs (not CPV18)

    – without additional supply connection

    – without additional supply connection with 4 or 8 inputs(not CPV18).

    The CPV valve terminals with AS-Interface connection can befitted with max. following valve sub-bases:

    Valve sub-base with... ASI-2 (...-Z) ASI-4 (...Z)...ASI-4E4A (...-Z)

    ...ASI-8E8A-Z

    ... two 2/2-way valves (single-solenoid) 1 2 4

    ... two 3/2-way valves (single-solenoid) 1 2 4

    ... 5/2-way valve (single-solenoid) 2 4 8

    ... 5/2-way valve (double-solenoid) 1 2 4

    ... 5/3-way valve 1 2 –

    Tab. 1/1: Maximum number of sub-bases on the CPV valve terminals with AS-Interfaceconnection

    The CPV valve terminals with AS-Interface connection and4�or 8 inputs have 4 or 8 valve sub-bases. These CPV valveterminals also have blanking plates depending on the numberof valve sub-bases.

  • 1. System summary

    1-7Festo P.BE-CPV-EN en 1609i

    1.2 Description of components

    Sizes of the CPV valve terminals

    The CPV valve terminals are available in the following sizes:

    CPV10 10�mm Micro valves

    CPV14 14�mm Mini valves

    CPV18 18�mm Midi valves

    Tab. 1/2: Sizes of the CPV valve terminals

  • 1. System summary

    1-8 Festo P.BE-CPV-EN en 1609i

    Identification code

    With the identification code (I.C.) you can ascertain the equipment fitted on your CPV valve terminal. The code is printed onthe front between manual overrides 12 and 14.

    I.C. Pneumatic components

    Valve sub-bases with 2/2-way valves

    D Two 2/2-way valves, single-solenoid, basic position closed

    DK Only for CPV10/14: two 2/2-way valves (with channel separation 1, 11), single-solenoid, basic�position closed

    I Two 2/2-way valves, basic position control side 14 open, control side 12 closed

    IK Only for CPV10/14: two 2/2-way valves (with channel separation 1, 11), basic position control side 14 open, control side 12 closed

    Valve sub-bases with 3/2-way valves

    C Two 3/2-way valves, single-solenoid, basic position closed

    CK Two 3/2-way valves (with channel separation 1, 11), single-solenoid, basic position closed

    CY Two 3/2-way valves (with back pressure flaps for exhaust channels 3, 5), single-solenoid,basic position closed, spring reset

    H Two 3/2-way valves, basic position control side 14 open, control side 12 closed

    HK Only for CPV10/14: two 3/2-way valves (with channel separation 1, 11), basic position control side 14 open, control side 12 closed

    N Two 3/2-way valves, basic position open

    NK Only for CPV10/14: two 3/2-way valves (with channel separation 1, 11), basic position open

    Valve sub-bases with 5/2-way valves

    F 5/2-way valve, single-solenoid, fast-switching

    J 5/2-way valve, double solenoid

    JK Only for CPV10/14: 5/2-way valve (with channel separation 1, 11), double solenoid

    M 5/2-way valve, single solenoid

    MK Only for CPV10/14: 5/2-way valve (with channel separation 1, 11) single solenoid

  • 1. System summary

    1-9Festo P.BE-CPV-EN en 1609i

    I.C. Pneumatic components

    Valve sub-bases with 5/3-way valves

    G CPV10/14: two 3/2-way valves, basic position closed + valve extension 5/3GCPV18: 5/3-way valve, mid-position closed

    Vacuum generator plates

    A Without reject pulse

    E With 2/2-way valve for reject pulse

    Separator plates

    S Exhaust channel (3/5) and compressed air channels (1, 11) closed

    T Compressed air channels (1, 11) closed

    Blanking plate

    L Plate without valve function for reserving a valve position

    Relay plate

    R Plate with two electrically-isolated relays

    Valve extensions

    P One-way flow control valve for restricting the supply air

    Q One-way flow control valve for restricting the exhaust air

    V Flow control valve for setting the reject pulse

    Tab. 1/3: Identification codes of the pneumatic components

    Further information on the valve sub-bases and vacuumgenerator plates can be found in appendix B.Important information on the valve with ident. code CY can befound in the following section.

  • 1. System summary

    1-10 Festo P.BE-CPV-EN en 1609i

    3/2-way valve (CY) with integrated one-way flowcontrol function

    The 2x3/2-way valves are provided with caps which prevent areverse effect of back pressures in exhaust channels 3 and 5on the drive connected to the valve.

    Note– Additional measures are needed when used in safety-

    relevant applications, e.g. in Europe, compliance withstandards listed under the EC Directive on Machinery.Without additional measures corresponding to legallyspecified minimum requirements, the product is notsuited as a safety-relevant part of controls.

    – If a separator plate is used between the valve plates (for forming pressure zones), we recommend the use ofseparator plate Ident. code S. This plate separates thesupply channnels 1, 11 and the exhaust channel 3/5.

    – Back pressures in the exhaust channel can prevent thevalve from switching. The valve switches as soon as theback pressure is reduced and the control signal is stillapplied.

    � Operate the CPV valve terminal fitted with valves withIdent. code CY with external pilot air. This ensures thatthe back pressure flaps are securely closed even with theoperating pressure switched off.

    Valve extension 5/3G (only CPV10/14)

    Valve extension 5/3G contains the function of two unlockablecheck valves. A function “5/3-way in mid-position closed” canbe implemented in conjunction with the valve sub-base withIdent code C (two 2/3-way valves in basic position closed).

    Further information on valve extension 5/3G can be foundunder “Fitting the valve extensions” in section 2.4 and under“General instructions” in section 4.1.

  • 1. System summary

    1-11Festo P.BE-CPV-EN en 1609i

    Flow control valve or one-way flow control valveextension

    With the following valve extensions you can adapt theCPV�valve terminal to the requirements of your machine orsystem.

    For restricting the supply or exhaust air of the valvesub-bases use valve extensions as follows:

    – One-way flow control valve for restricting the supply air(Ident. code P)

    – One-way flow control valve for restricting the exhaust air(Ident. code Q)

    For setting the reject pulse of the vacuum generator plate(Ident. code E):

    – Flow control valve (Ident. code V).

    The valve extensions are flange-fitted directly onto the valvesub-bases. It is not intended that the above-mentioned valveextensions should be combined.

    Further information on the valve extensions can be foundunder “Fitting the valve extensions” in section 2.4 and under“General instructions” in section 4.1.

  • 1. System summary

    1-12 Festo P.BE-CPV-EN en 1609i

    Vacuum generator plates

    CPV valve terminals can be fitted with vacuum generatorplates for generating vacuum. Work items with a smooth andtight surface can then be sucked in.

    Two types of vacuum generators are available:

    – Plate with switchable vacuum generator (Ident. code A).

    – Plate with switchable vacuum generator and additional2/2-way valve for generating the reject pulse (Ident. code A).

    Further information on the vacuum generator plates can befound under “Vacuum generator plates” in section 3.4.2.

    Separator plate

    By means of separator plates you can divide the CPV valveterminals into 2 to 4 pressure zones. Two types of separatorplates are available:

    – Separator plate with closed compressed air channels(1�and 11).

    – Only CPV10/14: Separator plate with closed exhaustchannel (3/5) and closed compressed air channels (1 and 11).

    Valve plates with channel separation

    You can implement pressure zones on CPV10/14 valveterminals also with valve plates with internal channelseparation (Ident. Code CK, DK, HK, IK, JK, MK and NK).Channel separation takes place in the compressed airchannels (1 and 11). 2�or 4 pressure zones can be formed.

  • 1. System summary

    1-13Festo P.BE-CPV-EN en 1609i

    Relay plate

    CPV10/14 valve terminals which have holding current reduction can be fitted with relay plates. This applies to CPV valveterminals with the following connection:

    – CPI/CP connection

    – CPV direct connection

    – AS-Interface connection (only CPV10 valve terminals)

    – IC connection (only in combination with connector socketNEBV-Z3WA2L-R-E-...-LE2-S1 (CPV10/14)

    – MP connection

    Each relay plate has two relays for actuating two electricallyisolated outputs.

  • 1. System summary

    1-14 Festo P.BE-CPV-EN en 1609i

    Pneumatic multipin

    The pneumatic multipin serves as a common connection forpower supply and work lines. Valve terminal type CPV10-...-VIis screwed together with the pneumatic multipin and sealedto it by means of sealing discs. The pneumatic multipin enables valve terminal type CPV10-...-VI to be easily disconnected from the pneumatic supply and work tubing. Thepneumatic multipin is available in two forms:

    1. Without mounting flange: This variant for fitting onto a stand or a wall opening fitsflush with the end plates. The fastening holes are in theconnection side of the pneumatic multipin (CPV10-VI-P...-M7).

    2. With mounting flange: With this variant for fitting onto a wall or stand thepneumatic multipin lies over the end plates: Themounting holes are located in the flange for ease ofmounting. Two additional holes running crosswaysthrough this pneumatic multipin (CPV10-VI-B) also allowrear mounting of valve terminal type CPV10-VI...

    3. Fitting into a control cabinet: with sealing ring and supply connections (CPV10-VI-P...-M7-C), with sealing ring, but without supply connections (CPV10-VI-P...-M7-D).

  • 1. System summary

    1-15Festo P.BE-CPV-EN en 1609i

    Pneumatic multipin without flange Pneumatic multipin with flange

    1

    11

    2

    Pneumatic multiple connector platewithout supply connctions

    Pneumatic multiple connector platewith supply connctions

    3 3

    1

    2

    1

    1

    1

    1

    1 Vertical mounting holes

    2 Horizontal mounting holes

    3 Sealing ring

    Fig. 1/2: Variants of the pneumatic multipin or pneumatic multiple connector plate

  • 1. System summary

    1-16 Festo P.BE-CPV-EN en 1609i

    The CPV valve terminal can consist of the followingcomponents, depending on what has been ordered:

    Overview of components

    1

    2

    3

    4

    5

    6

    1 Electrical sub-base (only CPV valve terminals with MP,AS-Interface or CPI/CP connections)

    2 Right-hand end plate (designs see section B.2 “Overview of end plates”)

    3 Relay plate (see also compatibility list in Tab. 5/2)

    4 Blanking plate or separator plate (with closed compressed air channels 1and 11 and exhaust channel (3/5) oronly closed compressed air channels 1and 11)

    5 Valve sub-bases fitted withsingle-solenoid, double-solenoid orvacuum valves

    6 Left-hand end plate (designs seesection B.2 “Overview of end plates”)

    Fig. 1/3: Components of the CPV valve terminal

  • 1. System summary

    1-17Festo P.BE-CPV-EN en 1609i

    Supplementary components of the CPV valveterminal

    The CPV valve terminal can be supplemented optionally bythe following components:

    1

    2

    3

    4

    5

    6

    1 Manual override cover and support for identification signs, not inconjunction with relay plate

    2 Pneumatic multipin

    3 Valve extensions (5/3G function (only CPV10/14),vacuum restrictor valve or one-wayflow control valve)

    4 Support for hat rail fitting forCPV10/14 or CPV18

    5 Support for wall fitting for CPV10/14or CPV18

    6 Support for wall fitting for CPV10/14

    Fig. 1/4: Supplements to the CPV valve terminal

  • 1. System summary

    1-18 Festo P.BE-CPV-EN en 1609i

    Connecting, display and operating elements

    You will find the following connecting, display and operatingelements on the CPV valve terminal:

    321 4

    5

    6

    77

    8

    6

    6

    1 Valve location for identification signs

    2 Manual override cover and support foridentification signs

    3 Manual override (per pilot solenoid,locking or non-locking)

    4 Removing the manual override cover

    5 Operating the non-locking manualoverride

    6 Supply air connections (1, 11, 12/14),exhaust air connections (3/5, 82/84):with individual tubing on the leftand/or right-hand end plate, with central tubing on the pneumaticmultipin

    7 Work connections (2, 4) per valve

    8 Pneumatic multipin

    Fig. 1/5: Pneumatic connecting, display and operating elements of the CPV valveterminal

    Instructions on the electrical connecting and display elementsof the CPV valve terminals with direct connection can befound in the appropriate electronics manuals.

  • 1. System summary

    1-19Festo P.BE-CPV-EN en 1609i

    You will find the following electrical connecting and displayelements on the CPV valve terminal with IC connection:

    1

    3

    4

    5

    6

    2

    1 Identification sign (for each connector socket)

    2 Ready-to-use connector socket (for each pilot solenoid), can be turned 180°

    3 Yellow LED, signal status displays for pilot solenoid (for each connector socket)

    4 Earth connection

    5 Terminal lugs of pilot solenoid coil 14

    6 Terminal lugs of pilot solenoid coil 12

    Fig. 1/6: Electrical connecting and display elements of the CPV valve terminal with IC connection

  • 1. System summary

    1-20 Festo P.BE-CPV-EN en 1609i

    You will find the following electrical connecting and displayelements on the CPV valve terminal with MP connection:

    1

    2

    3

    4

    1 SUB-D multipin plug (9-pin forterminals with 4 valves, 25-pin forterminals with 6 or 8 valves)

    2 Identification signs

    3 Yellow LED, signal status displays ofthe pilot solenoids

    4 Earth connection

    Fig. 1/7: Electrical connecting and display elements of the CPV valve terminal with MP connection

  • 1. System summary

    1-21Festo P.BE-CPV-EN en 1609i

    You will find the following electrical connecting and displayelements on the CPV valve terminal with CPI/CP connection:

    ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

    ÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

    1

    2

    3

    4

    5

    6

    7

    8

    1 Incoming CP cable

    2 Continuing CP cable

    3 Identification signs

    4 Yellow LED, signal status display of the relays

    5 Yellow LED, signal status displays of the pilot solenoids

    6 Relay connectionswith connectingcable

    7 Earth connection

    8 Green LED, status dislpay of theCP�connection

    Fig. 1/8: Electrical connecting and display elements of the CPV valve terminal with CPI/CP connection

  • 1. System summary

    1-22 Festo P.BE-CPV-EN en 1609i

    You will find the following electrical connecting and displayelements on the CPV valve terminal with AS-Interfaceconnection:

    ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

    ÎÎÎÎ

    ÎÎÎÎÎÎÎÎÎÎÎÎ

    ÎÎÎÎÎÎÎÎÎ

    8

    7

    6

    5

    3

    21

    4

    9

    1 AS-Interface cable cap,(only�CPV...-GE-ASI-...-Z)

    2 Cable socket of the additional supply with black cable,(only�CPV...-GE-ASI-...-Z)

    3 Sensor cable with plug(only�CPV...-GE-ASI-...E...A-...)

    4 Identification signs

    5 Yellow LED, signal status displays ofthe pilot solenoids

    6 Earth connection

    7 BUS LED 1 (green),BUS LED 2 (red), (only CPV...-GE-ASI-...E...A-...)

    8 Green LED status displays of theinputs, (only CPV...-GE-ASI-...E...A-...)

    9 AS-Interface bus socket with yellowbus cable

    Fig. 1/9: Electrical connecting and display elements of the CPV valve terminal with AS-Interface connection

  • Fitting

    2-1Festo P.BE-CPV-EN en 1609i

    Chapter 2

    Fitting

  • 2. Fitting

    2-2 Festo P.BE-CPV-EN en 1609i

    Contents

    2. Fitting 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.1 General instructions on fitting and dismantling 2-3. . . . . . . . . . . . . . . . . . . . . . .

    2.2 CPV valve terminal with individual tubing 2-3. . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.1 Wall mounting 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.2 Hat rail mounting 2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.3 Fitting onto a stand 2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.4 Fitting into a control cabinet 2-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2.5 Fitting the CPV valve terminal to the SIMATIC ET200X 2-12. . . . . . . . . .

    2.2.6 Fitting the CPV valve terminal onto SIMATIC ET200pro 2-15. . . . . . . . . .

    2.3 CPV valve terminal with pneumatic multipin 2-16. . . . . . . . . . . . . . . . . . . . . . . . .

    2.3.1 Fitting the pneumatic multipin 2-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.3.2 Fitting the CPV valve terminal to the pneumatic multipin 2-20. . . . . . . .

    2.4 Fitting the valve extensions 2-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.5 Fitting the identifier support 2-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.6 Fitting covers on the manual overrides 2-24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 2. Fitting

    2-3Festo P.BE-CPV-EN en 1609i

    2.1 General instructions on fitting and dismantling

    WarningSudden unexpected movements of the connected actuators and uncontrolled movements of loose tubing cancause injury to human beings and/or damage to property.

    Before carrying out installation and maintenance work,switch off the following:

    � the compressed air supply

    � the operating and load voltage supplies.

    NoteHandle all modules and components of the valve terminalwith great care. Note especially the following:

    � The specified torques must be observed.

    � Electrostatically sensitive components.Do not therefore touch any contact surfaces.

    2.2 CPV valve terminal with individual tubing

    Fitting variants

    The CPV valve terminal with individual tubing has alreadybeen prepared for integration in a system or machine for thefollowing fitting variants:

    – Wall mounting

    – H-rail mounting

    – Fitting onto a stand

    – Fitting into a control cabinet

  • 2. Fitting

    2-4 Festo P.BE-CPV-EN en 1609i

    NoteIf vibrations, which exceed the following values, occur onyour application:

    � 0.15 mm path at 10 … 58 Hz

    � 2 g acceleration at 58 … 150 Hz

    you should mount the CPV14 or CPV18 valve terminal on awall or on a stand.

    2.2.1 Wall mounting

    In order to fit the CPV valve terminal onto a wall, you willrequire the appropriate mounting kit, depending on the typeof mounting. The following table provides an overview:

    Mounting method

    Rear On head side (only CPV10/14 with IC connection)

    Mounting kits (consisting of 2 profile sections and 4 self-threading screws):see Festo catalogue } www.festo.com

    Tab. 2/1: Fastening profile sections for fitting onto a wall

  • 2. Fitting

    2-5Festo P.BE-CPV-EN en 1609i

    For rear fitting of the CPV10/14 valve terminals with directconnection for Interbus Loop (type CPV...-GE-IL-...) orAS-Interface connection with inputs/outputs (type CPV...-GE-ASI...E/...A) there is a special mounting kitwhich is not listed here.

    Proceed as follows:

    � Make sure that the fastening surface can support theweight of the CPV valve terminal.

    � Fit the fastening profile section to the left-hand and right-hand end plates (see Fig. 2/2). Use here the self-threading screws supplied (see table). When fitting theCPV10/14 valve terminals “from the rear”, make sure thatthe fixing bolts of the fastening profile sections grip intothe recess in the end plates.

    Valve terminal Type of mounting: Rear Type of mounting: Front

    self-threadingscrew

    tightening torque self-threadingscrew

    tightening torque

    CPV10/14 M4 x 10 1.5 Nm M3 x 18 1.5 Nm ± 0.2 Nm

    CPV18 M5 x 10 4�Nm – –

    Tab. 2/2: Fitting onto a wall, tightening torques

  • 2. Fitting

    2-6 Festo P.BE-CPV-EN en 1609i

    Type of mounting: Rear Type of mounting: Front

    ÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓ

    1

    2

    3

    4

    1

    1

    2

    2

    1

    1

    2

    2

    1 M4 (CPV10/14) or M5 screw (CPV18)for fastening onto a wall

    2 Additional self-threading screw withCPV18 valve terminals

    3 Self-threading screws for fastening the profile sections onto the CPV valveterminal

    4 Fixing bolts (only CPV10/14)

    1 5.5 mm bore for wall fastening

    2 Self-threading screws for fastening the profile sections onto the CPV valveterminal

    Fig. 2/1: Connecting the CPV valve terminal

    � Make sure there is sufficient space for connecting thesupply cables and tubing. For front mounting it will benecessary to cut out a suitable section for the electricalconnections or to use a suitable spacer.

    NoteThe hole dimensions for rear fitting of the CPV valveterminal (Tab. 2/3) do not apply to CPV10/14 valveterminals with direct connection for Interbus Loop(type�CPV...-GE-IL-...) or AS-Interface connection withinputs/outputs (type CPV...-GE-ASI...E/...A).

  • 2. Fitting

    2-7Festo P.BE-CPV-EN en 1609i

    1 Mounting options

    1

    Fig. 2/2: Fastening holes for the rear fitting

    Drill four mounting holes or threaded holes in the fasteningsurface (see table).

    Valve terminal Type of mounting: Rear Type of mounting: Front

    Diameter of thefastening holes

    Threaded hole for Diameter of thefastening holes

    Threaded hole for

    CPV10/14 4.5 mm M4 screw 5.5 mm M5 screw

    CPV18 5.5 mm M5 screw – –

    Tab. 2/3: Holes for wall fitting

    � Fasten the CPV valve terminal with four M4 or M5 screwsof sufficient length to the wall.

  • 2. Fitting

    2-8 Festo P.BE-CPV-EN en 1609i

    2.2.2 Hat rail mounting

    In order to fit the CPV valve terminal onto a hat rail you willrequire the following mounting kits (see Festo catalogue: } www.festo.com): Both mounting kits consist of 2 brackets, 2 or 4 M4x10 self-threading screws (CPV10/14) or M5x10 (CPV18) and 2 M4x10screws with clamping elements and springs.

    Proceed as follows:

    � Make sure that the fastening surface can support theweight of the CPV valve terminal.

    � Fit the following hat rail:

    Hat rail for CPV10/14 valveterminal

    Hat rail for CPV18 valveterminal

    Support rail DIN 50022 – 35x7.5,(width 35 mm, height 7.5 mm)

    Support rail DIN 50022 – 35x15(width 35 mm, height 15 mm)

    Tab. 2/4: Hat rails

    � Make sure that there is sufficient space for connecting thesupply cables and tubing, and that extra space is available for fitting CPV valve terminals with large surface-mounted silencers.

    � Fasten the hat rail to the fastening surface approximatelyevery 100 mm.

    � Fasten the two brackets to the end plates with the screwssupplied as shown in the diagram below. With CPV10/14valve terminals, make sure that the fastening bolts of thebrackets grip into the recess in the CPV valve terminal.

    CPV valveterminal

    Self-threadingscrew

    Tightening torque

    CPV10/14 M4x10 1.5 Nm

    CPV18 M5x10 4 Nm

    Tab. 2/5: Hat rail adapter, tightening torques

  • 2. Fitting

    2-9Festo P.BE-CPV-EN en 1609i

    1 Per end plate oneM4x10 screw(CPV10), twoM4x10 screws(CPV14) orM5x10 (CPV18)

    2 H-rail

    3 Fixing bolts (only CPV10/14)

    4 H-rail clampingunit

    1

    2

    3

    4

    Fig. 2/3: Fitting the valve terminal on a hat rail

    � Hang the CPV valve terminal onto the hat rail. Secure theCPV valve terminal on both sides with the hat railclamping unit against slipping or sliding down.

  • 2. Fitting

    2-10 Festo P.BE-CPV-EN en 1609i

    2.2.3 Fitting onto a stand

    In order to fit the CPV valve terminal onto a stand (fitting onthe level of work connections 2 and 4), you will require thefollowing fastening screws:– 4 M4x45 socket head screws (CPV10)– 4 M4x50 socket head screws (CPV14)– 4 M6x65 socket head screws (CPV18)

    Proceed as follows:

    � Prepare the fastening surface. If necessary, make a suitable bracket. The position of the mounting holes of theCPV valve terminal is shown in the following diagram:

    1 Fastening holes

    1 1

    Fig. 2/4: Fastening holes for fitting onto a stand

  • 2. Fitting

    2-11Festo P.BE-CPV-EN en 1609i

    � Make sure that there is sufficient space for connecting thesupply cables and tubing, and that extra space is available for fitting CPV valve terminals with large surface-mounted silencers.

    � With CPV valve terminals with IC connection:Insert the four socket head screws supplied into the holesin the left-hand and right-hand end plates (see diagram).

    1 Socket headscrews M4 x 45or M4 x 50 orM6 x 65

    2 End plates

    3 Fastening bracket

    11

    2

    2

    3

    Fig. 2/5: Position of the fastening holes

    � Screw the CPV valve terminal to the connection surface orto the fastening bracket.

    2.2.4 Fitting into a control cabinet

    See chapter 2.2.3.

  • 2. Fitting

    2-12 Festo P.BE-CPV-EN en 1609i

    2.2.5 Fitting the CPV valve terminal to the SIMATIC ET200X

    Instructions on the decentral periphery device ET200X can befound in the relevant manual from SIEMENS AG.

    A CPV valve terminal with

    � IC connection,

    � 8 valve sub-bases,

    � mounted fastening CPV...-VI-BG-ET200X and

    � appropriate flat seal

    can be mounted on a pneumatic interface module typeEM�148-P-DO 16 x P/CPV... for the decentral periphery deviceET200X.

    When the terminal is fitted into place, the switching status ofthe valve solenoid coils can be seen on the relevant LED onthe pneumatic interface module.

  • 2. Fitting

    2-13Festo P.BE-CPV-EN en 1609i

    Assembly

    Proceed as follows:

    1. The fastening is already fitted to the CPV valve terminal.Make sure that the flat seal is placed correctly over theterminal lugs and the centring bolt which lies betweenthem (see Fig. 2/6).

    2. Mark the positions of the four holes for the fasteningscrews on the background.Tip: Hold the pneumatic interface module against themounting surface and mark the positions of the holes.Drill the four fastening holes for screws of size M5.

    1 Fastening

    2 Terminal lug withcentring bolt

    1 2

    Fig. 2/6: Preparing for fitting onto the SIMATIC ET200X

    3. Place the valve terminal carefully and without tilting ontothe pneumatic interface module.–�Insert the centring pins in the appropriate holes.–�Do not bend the terminal lugs.Screw tight the valve terminal and the pneumatic interface module on the mounting surface with four screws(see Fig. 2/7).

  • 2. Fitting

    2-14 Festo P.BE-CPV-EN en 1609i

    1 M5 screws, atleast 60 mm long(ISO�1207/ISO�1580 – DIN�84or DIN�912)

    2 Centering pins

    1

    2

    2

    Fig. 2/7: Fitting the CPV valve terminal onto the Siemens SIMATIC ET200X

    NoteRemoving the CPV valve terminal from the pneumaticinterface module:

    � pull the CPV valve terminal carefully upwards withouttilting.

    When refitting the CPV valve terminal onto the pneumaticinterface module:

    � replace the flat seals on the following CPV valveterminals if they have been operated in a dirtyenvironment:

    – type CPV10-GE-8– type CPV14-GE-8

  • 2. Fitting

    2-15Festo P.BE-CPV-EN en 1609i

    2.2.6 Fitting the CPV valve terminal onto SIMATIC ET200pro

    A CPV valve terminal with:

    � IC connection,

    � 8 valve sub-bases,

    � and appropriate flat seal

    can be mounted on the SIEMENS pneumatic interface module16 DO DC24V CPV... for the decentral periphery deviceET200pro.

    Instructions on fitting the CPV valve terminal to the decentralperiphery device ET200pro can be found in the correspondingmanual from SIEMENS AG.

  • 2. Fitting

    2-16 Festo P.BE-CPV-EN en 1609i

    2.3 CPV valve terminal with pneumatic multipin

    Only CPV valve terminals fitted with appropriate end platesmay be mounted on the pneumatic multipin. CPV valveterminals with end plates for individual tubing need to beconverted before they can be fitted onto the pneumaticmultipin. For this purpose fit the appropriate end plates (see section 5.5 “Converting the end plates” and section B.2“Overview of the end plates”).

    The pneumatic multipin is available in four variants(see�chapter 1 “System overview” Fig. 1/2):

    1. without mounting flange

    2. with mounting flange

    3. fitting into a control cabinet.

    CPV valve terminals with large surface-mounted silencers,which are fitted onto the pneumatic multipin with mountingflange, can only be fitted onto a wall. Use here the holesrunning diagonally through the pneumatic multipin. Themounting holes running vertically through the pneumaticmultipin are covered by the large surface-mounted silencer.

  • 2. Fitting

    2-17Festo P.BE-CPV-EN en 1609i

    2.3.1 Fitting the pneumatic multipin

    Make sure that the fastening surface can support the pneumatic multipin and the CPV valve terminal. Make sure thatthere is sufficient space for connecting the supply cables andtubing, and that extra space is available for fitting CPV valveterminals with large surface-mounted silencers.

    Fitting the pneumatic multipin (connection side)

    Proceed as follows in order to fit the pneumatic multipin withthe connection side onto a fastening surface:

    � Cut out an opening in the fastening surface.

    � Drill four mounting holes in the fastening surface(diameter see Tab. 2/6). Position of these holes(see�Tab. 2/7).

    � Screw the pneumatic multipin to the fastening surfacewith four screws of sufficient length (see table).

    Pneumatic multipin (without flange)

    Pneumatic multipin(with flange)

    CPV10/14 CPV18 CPV10/14/18

    4.5 mm 5.5 mm 6.5 mm

    M4 M5 M6

    Tab. 2/6: Diameter of the fastening holes and screw size

  • 2. Fitting

    2-18 Festo P.BE-CPV-EN en 1609i

    CPV10/14 CPV18

    without flange:

    1 1 1 1

    with flange:

    1 11 1

    Tab. 2/7: Position of the holes for the pneumatic multipin

  • 2. Fitting

    2-19Festo P.BE-CPV-EN en 1609i

    Fitting the pneumatic multipin (rear side)

    Proceed as follows in order to fit the pneumatic multipin(with�flange) with its rear side onto a mounting surface:

    � Drill two mounting holes in the fastening surface forscrews of size M6. Position of and distance between theseholes see table.

    1

    Dimensions 1

    Number ofvalve locations

    CPV10 CPV14 CPV18

    2 62 mm 80 mm 107 mm

    4 82 mm 108 mm 143 mm

    6 102mm 136 mm 179 mm

    8 122 mm 164 mm 215 mm

    Tab. 2/8: Hole dimensions for rear fitting

    � Screw the pneumatic multipin to the fastening surfacewith two M6 screws of sufficient length.

  • 2. Fitting

    2-20 Festo P.BE-CPV-EN en 1609i

    2.3.2 Fitting the CPV valve terminal to the pneumatic multipin

    Proceed as follows:

    � With CPV valve terminals with IC connection, insert thesocket head screws supplied into the fastening holes.With MP, AS-Interface, DI or CPI/CP connections, thesocket head screws are already in the fastening holesunder the electrical sub-base and are secured againstloss.

    � Place the 3-part or 4-part seal for sealing the supplychannels into the grooves in the left or right-hand endplate.

    � In order to seal the work channels, carefully press the twoseals into the threads of the work connections.

    � Fasten the CPV valve terminal with the 4 socket headscrews on the multipin. Tighten the screws in diagonallyopposite sequence with 2 Nm (CPV10/14) or 4 Nm(CPV18).

    1 3-part seal in theconnections ofthe left-hand endplate

    2 2 seals per valvesub-base for thework connections

    3 4-part seal in theconnections ofthe right-handend plate

    4 Socket headfastening screwsof the pneumaticmultipin

    1

    2

    4 3

    Fig. 2/8: Fitting the CPV valve terminal onto the pneumatic multipin

  • 2. Fitting

    2-21Festo P.BE-CPV-EN en 1609i

    Instructions on fitting the CPV valve terminal to the pneumatic multiple connector plate can be found in the followingassembly instructions:

    1. CPV10-VI-P… – for valve terminal CPV10

    2. CPV14-VI-P… – for valve terminal CPV14.

  • 2. Fitting

    2-22 Festo P.BE-CPV-EN en 1609i

    2.4 Fitting the valve extensions

    Note� If the pneumatic multipin is used with mounting flange,

    the outer valve sub-bases cannot be fitted with valveextensions.

    � The valve extension 5/3G is intended for use with oneworking pressure for each valve sub-base, i.e. it mustnot be used in two-pressure operation (different pressure at connections 1 and 11).

    � If other valve sub-bases are to be fitted onto the CPVvalve terminal in two-pressure mode, the valve sub-basefitted with the 5/3G valve extension must be separatedfrom compressed air channels 1 and 11 by means of adividing plate.

    � The valve extension 5/3G cannot be fitted in conjunctionwith the pneumatic multiple connector plate typeCPV10-VI-P...-C or CPV10-VI-P...-D.

    Proceed as follows:

    � Place the seals supplied with the product into therecesses in the appropriate valve extension.

    � Fasten the valve extension with the screws supplied with0.8 Nm (CPV10) or 1.2 Nm (CPV14).

    � Connect the work lines as described under “Connectingthe supply and work lines” in the section 3.4.2.

    � Note that the flow control valve extensions or one-wayflow control valve extensions (Ident. code P, Q and V)require a minimum operating pressure of 0.5 bar.

  • 2. Fitting

    2-23Festo P.BE-CPV-EN en 1609i

    2.5 Fitting the identifier support

    Before the valve identifier signs can be fitted, the CPV valveterminal must be fitted with an identifier support. This willalso protect the manual overrides against unauthorisedoperation. It should be fitted at the front above the manualoverride.

    The identifier support cannot be fitted if the CPV valveterminal is equipped with relay plates.

    Proceed as follows:

    � Clip the identifier support into the recess in the left andright-hand end plates (see diagram).

    � Clip the identifier signs into the grooves in the identifiersupport (see diagram).

    1

    2

    1 Valve identifier labels

    2 Identifier support

    Fig. 2/9: Fitting the identifier support

  • 2. Fitting

    2-24 Festo P.BE-CPV-EN en 1609i

    2.6 Fitting covers on the manual overrides

    Individual covers can be fitted over the manual overrides toprotect them against unauthorized use.

    The manual override covers are not intended for re-use. Fitthe manual override covers only if you no longer require themanual overrides (e.g. after testing the valves).

    Proceed as follows:

    � Clip the covers into the guide grooves on the manual overrides (see Fig. 2/10).

    If your valve terminal type CPV10-EX-VI is equipped withnon-locking manual overrides, you must remove theretaining clips before fitting the covers (see section 5.4,Fig. 5/6).

    1

    2

    1

    1 Guide grooves on the manual overrides

    2 Cover for the manual override

    Fig. 2/10: Fitting covers on the manual overrides

  • Installation

    3-1Festo P.BE-CPV-EN en 1609i

    Chapter 3

    Installation

  • 3. Installation

    3-2 Festo P.BE-CPV-EN en 1609i

    Contents

    3. Installation 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.1 Preparing the compressed air 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.1.1 Operation with non-lubricated compressed air 3-3. . . . . . . . . . . . . . . .

    3.1.2 Operation with lubricated compressed air 3-4. . . . . . . . . . . . . . . . . . . .

    3.2 General instructions on installation 3-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.3 Laying the tubing 3-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.4 Connecting the CPV valve terminal 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.4.1 Pilot air supply 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3.4.2 Connecting the supply and work lines 3-12. . . . . . . . . . . . . . . . . . . . . . .

    3.4.3 Connecting the electric cables 3-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 3. Installation

    3-3Festo P.BE-CPV-EN en 1609i

    3.1 Preparing the compressed air

    CautionDirty or incorrectly lubricated compressed air will reducethe service life of the valve terminal.

    3.1.1 Operation with non-lubricated compressed air

    CautionToo much residual oil in the compressed air will reduce theservice life of the valve terminal.

    � If bio-oils are used (oils with synthetic ester or true esterbasis, e.g. rape oil methylester), the residual oil contentmust not exceed 0.1 mg/m3 (see ISO 8573-1 class 2).

    � If mineral oils are used (e.g. HLP oils as per DIN 51524parts 1 to 3) or corresponding oils on a polyalphaolefinebasis (PAO), the residual oil content must not exceed5�mg/m3 (see ISO 8573-1 class 4).

    You will thereby avoid functional damage to the valves.

    Excessive residual oil cannot be permitted irrespective of thecompressor oil, as otherwise the basic lubrication will bewashed out during the course of time.

  • 3. Installation

    3-4 Festo P.BE-CPV-EN en 1609i

    3.1.2 Operation with lubricated compressed air

    Operate your system with non-lubricated compressed air ifpossible. This will prevent pollution of the environment. Festopneumatic valves and actuators have been designed so that,if used as intended, they will not require additional lubrication and will still achieve a long service life.

    CautionOperation with lubricated compressed air will cause theservice life lubrication, which is necessary for non-lubricated operation, to be “washed out”.

    Note the following instructions if lubricated compressed airmust be used. The compressed air prepared with the compressor mustcorrespond in quality to non-lubricated compressed air. Ifpossible, do not operate the complete system with lubricatedcompressed air. If possible, always install the lubricatorsdirectly in front of the consuming actuator.

    CautionIncorrect additional oil and too much residual oil content inthe compressed air will reduce the service life of the valveterminal.

    � Use Festo special oil OFSW-32 or the other oils listed inthe Festo catalogue (as per DIN 51524-HLP32, basicviscosity 32 CST at 40 °C).

    � The additional lubrication must not exceed 25 mg/m3

    (ISO 8573-1 class 5).

    � Make sure that the lubricator setting is correct (see following section)

    You will thereby avoid functional damage to the valves.

  • 3. Installation

    3-5Festo P.BE-CPV-EN en 1609i

    Setting the lubricator with the machine running (typical operating status) 0.2 tomax. 1 drop/min. or 0.5 to 5 drops/1000 l air.

    Checking the setting the procedure described below can be used for checking thesetting of the lubricator.

    Proceed as follows:

    � Check the service units in respect of condensate andlubricator setting twice a week.

    1. Ascertain the cylinder which is furthest from thelubricator.

    2. Ascertain the valve terminal which controls this cylinder.

    3. Remove the silencer, if fitted, from connection 3/5.

    4. Hold a piece of white cardboard 10 cm in front of theexhaust port.

    5. Let the system run for a short period.

    – There must be only a slight yellow colouring on thecardboard. If oil drops out, this is an indication thattoo much oil has been used.

    Another indication of over-lubrication is the colouring or thecondition of the exhaust air silencer. A distinctly yellowcolouring of the filter element or drops of oil on the silencerindicate that the lubricator setting is too high.

  • 3. Installation

    3-6 Festo P.BE-CPV-EN en 1609i

    3.2 General instructions on installation

    WarningSudden unexpected movements of the connected actuators and uncontrolled movements of loose tubing cancause injury to human beings and/or damage to property.

    Before carrying out installation and maintenance work,switch off the following:

    � the compressed air supply

    � the operating and load voltage supplies.

    NoteObserve the following if the UL requirements are to becomplied with in your application:

    � Rules for observing the UL certification can be found inthe separate UL-specific documentation. The relevanttechnical specifications listed there also apply here.

    � The technical specifications in this documentation mayshow different values.

    Pay particular attention to the following:The components of the valve terminal contain electrostaticallysensitive elements. The components will be damaged if youtouch the contact surfaces of the plug connectors or if you donot observe the regulations for handling electrostaticallysensitive components.

  • 3. Installation

    3-7Festo P.BE-CPV-EN en 1609i

    3.3 Laying the tubing

    If elbow screw connectors or multiple distributors are used,the airflow will be reduced slightly.

    Connecting Proceed as follows:

    1. Push the tubing as far as possible into or over the tubecoupling of the threaded connector.

    2. Tighten the clamping screw 1 or, if applicable, pull thelocking ring 2 over the tube coupling.

    3. Seal connections that are not required with blankingplugs 3.

    4. For better system clarity, group the tubing together with:– tubing straps or – multiple hose holders

    1

    2

    3

    Fig. 3/1: Fitting the tubing

  • 3. Installation

    3-8 Festo P.BE-CPV-EN en 1609i

    Disconnecting Proceed as follows:

    WarningIf the pneumatic tubing is under pressure when connections are loosened, it may perform sudden unexpectedmovements, thereby causing injury to human beings. Carry out the following steps before disconnecting thepneumatic tubing on the CPV valve terminal:

    � Switch off the compressed air supply.

    � Make sure that all pneumatic tubing is pressureless.

    � Exhaust all actuators controlled by valves which areclosed in the rest or mid-positions.

    1. Mark all pneumatic tubing.

    2. Loosen the clamping screw 1 of the fitting or, if necessary, press down the locking ring of the fitting 2, e.g. with the QSO releasing tool from Festo.

    3. Remove the tubing from the threaded connector.

    1

    2

    Fig. 3/2: Disconnecting the tubing

  • 3. Installation

    3-9Festo P.BE-CPV-EN en 1609i

    3.4 Connecting the CPV valve terminal

    In order to guarantee the optimum efficiency of your CPVvalve terminal, we recommend in the following cases that youconnect the compressed air tubing and, if necessary, also theexhaust air tubing on both sides (appropriate end plate pairssee appendix B.2 “Overview of the end plates”):

    – when large volume cylinders are operated at high speeds

    – when several valves are switched simultaneously to theflow position.

    Note� CPV valve terminal with two pressure zones:

    Connect the supply pressures to the end plates or toboth sides of the pneumatic multipin.

    3.4.1 Pilot air supply

    Caution� If possible, operate the CPV valve terminal with

    non-lubricated pilot air (connections 12/14). Otherwiseobserve the instructions in the section 3.1.2 “Operationwith lubricated compressed air”.

    � In the case of CP valve terminals with internallybranched pilot air, the above mentioned remark alsoapplies to the supply air (connection 1/11).

    With CPV valve terminals with two pressure zones andinternally branched pilot air:

    � Due to the internally branched pilot air in the right-handend plate, the pressure in the right-hand pressure zonemust be 3 … 8 bar.

  • 3. Installation

    3-10 Festo P.BE-CPV-EN en 1609i

    The CPV valve terminal is intended for internal or externalpilot air supply, depending on the end plates fitted. Pleaserefer to your order forms or to the Tab. B/6 in section B.2 toascertain which types of end plates are fitted on your CPVvalve terminal.

    Note� Operate a CPV valve terminal fitted with valves with

    Ident. code CY with external pilot air. You can then besure that the back pressure flaps are reliably closed,even when the operating pressure is switched off.

    Internal pilot air supply

    If the supply pressure of your CPV valve terminal lies between3�…�8 bar, you can operate with internally branched pilot air.In this case the pilot air will be branched from connection 1 or11 in the left or right-hand end plate.

    NoteUsing the CPV valve terminal with internally suppliedpilot�air:

    � Seal connection 12/14 with a blind plug.

  • 3. Installation

    3-11Festo P.BE-CPV-EN en 1609i

    External pilot air supply

    If the supply pressure of your CPV valve terminal lies between3�…�8 bar, you can operate the terminal with external pilot air.In this case the pilot air is supplied via connection 12/14 onthe CPV valve terminal. End plates for supplying the CPVvalve terminal with external pilot air see section B.2“Overview of end plates”.

    Note� Use regulated external pilot air (3 … 8 bar). Reliable

    faultless operation of the CPV valve terminal is thenpossible.

    � Please note that the regulated externally supplied pilotair for all valve sub-bases on the CPV valve terminalneed only be supplied or branched at one position withcommon tubing. This also applies if the CPV valveterminal is operated with different pressure zones(see�figure).

    1 Separator plate

    2 Blanking plug

    3 Pressure zone 2

    4 Pressure zone 1ÓÓÓÓÎÎÎÎ

    ÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓÓ

    ÓÓÓÓÓÓÓÓ

    1

    2

    34

    Fig. 3/3: Pilot air supply

  • 3. Installation

    3-12 Festo P.BE-CPV-EN en 1609i

    3.4.2 Connecting the supply and work lines

    Note� Unused connections Seal all connections not required

    for functioning with blind plugs (see appendix B).

    � Unused valve sub-bases Seal work connections 2 and 4with blanking plugs.

    � Valve sub-bases with Ident. code C (two 3/2-way valvesclosed in basic position): With the 5/3G valve extension you can implement thefunction “closed in mid-postion” with this CPV10/14valve sub-base. This valve extension is mounted on theconnection side of the above-mentioned valve sub-base(see section 2.4 “Fitting the valve extensions”).

    � Connect the work lines as follows, depending on the toolyou are using:

    � screw connector with hexagon socket head: any sequence is possible.

    � screw connector with external hexagon socket head:connection must be made from left to right (space forwrench).

  • 3. Installation

    3-13Festo P.BE-CPV-EN en 1609i

    Fit the screw connector or the silencers according to the tablebelow. Then connect the tubing.

    Pneumatic multipin CPV valve terminal

    1

    3/5

    11

    2

    4

    11

    82/84

    12/14

    1

    2

    4

    11 12/14

    3/5

    1

    82/84

    ConnectionidentifierISO 5599

    Tubing Connection size ISO 228, specification in bracket is for

    pneumatics multipin with

    flange

    Connection

    CPV10 CPV14 CPV18

    1 or 11 Compressed air/vacuum

    G1/8 G1/4 G3/8 Screw connector in endplates or pneumaticmultipin

    2 or 4 Work air/vacuum M7G1/8

    G1/8 G1/4 Connector

    3/5 Exhaust right-hand/left-hand end platePneumatic multipin,

    G3/8G1/4

    G1/2G3/8

    G1/2G1/2

    Connector– for ducted exhaust air– for silencer

    12/14 or82/84

    Pilot air supply orexhaust right-hand/left-hand end platePneumatic multipin

    M5M7 (M5)

    G1/8G1/8

    G1/4G1/4

    Screw connector atconnection 82/84– for ducted exhaust air– for silencer

    Tab. 3/1: Sizes of the pneumatic connections

  • 3. Installation

    3-14 Festo P.BE-CPV-EN en 1609i

    NoteIn the case of several systems with centrally ductedexhaust: Use check valves in the common exhaust lines in order toprevent functional impairment due to back pressures.

    1 CPV valveterminal 1

    2 Common 3/5

    3 Common 82/84

    4 CPV valveterminal 2

    5 Central 3/5

    6 Central 82/84

    1 2 3 4

    52

    2

    6 3

    Fig. 3/4: Common lines with check valves

    NoteThe exhaust is removed via channels 3/5 and 82/84. These connections must not be sealed with blanking plugs.

    Exhaust channels 3 and 5 are grouped together in the CPVvalve terminal. Separate exhaust restriction of channels 3or 5 is not therefore possible.

    Restriction of exhaust 3/5 on the vacuum generator plates(Ident. codes A and E) is not permitted.

  • 3. Installation

    3-15Festo P.BE-CPV-EN en 1609i

    NoteWith CPV valve terminals with ducted supply air:

    seal connections 11 and 12/14 with blanking plugs

    Pressure zones of the CPV valve terminals

    The CPV valve terminal can be operated with one, two or fourpressure zones depending on the components fitted. Themaximum number of pressure zones possible is determinedby the combination of the following:

    – using a separator plate or a valve plate with channelseparation (Ident. Code CK, DK, HK, IK, JK, MK or NK,see�appendix B, section B.1)

    – the type of end plate pairs (see section B.2)

    – the type of valve sub-bases (see section B.1).

    NoteWith CPV valve terminals with two pressure zones andinternally branched pilot air in the right-hand end plate:

    � Due to the internally branched pilot air, the pressure inthe right-hand pressure zone must be 3 … 8 bar.

    NoteFor building pressure zones with CPV valve terminals with3/2-way valves with back pressure flaps (Ident. code CY):

    � Festo recommends the use of the separator plate withIdent. code S. This plate separates the supply channels 1,11 and the exhaust channel 3/5.

    � Aways apply the same pressure in a pressure zone toconnections 1 and 11.

    � Back pressures in the exhaust channel can prevent thevalve from switching. The valve switches as soon as theback pressure is reduced and the control signal is stillapplied.

  • 3. Installation

    3-16 Festo P.BE-CPV-EN en 1609i

    Vacuum/low-pressure operation

    The CPV valve terminal can be operated with vacuum or lowpressure (. 3 bar), if regulated pilot air is applied separately.An overview of the end plates required can be found insection B.2.

    NoteNote that the valve with Ident. code CY is not suitable foroperation with vacuum.

    Vacuum generator plates

    NoteA high back pressure in exhaust channel 3/5 will impairthe functioning of the vacuum generator.

    � Make sure that there is optimal exhausting

    If the CPV valve terminal is fitted with valve sub-bases andvacuum generator plates, the exhaust air from the valvesub-bases (in channel 3/5) can influence the vacuumgeneration.

    � In this case, separate exhaust channel 3/5 between thevacuum generator plates and the valve sub-bases bymeans of the separator plate with Ident. code S.

    Connect the work lines to the vacuum generator plate

    Vacuum valve sub-base with Ident. code A:

    � Connect the vacuum suction nozzle to work connection 4.

    � Seal work connection 2 with a blanking plug.

    Vacuum valve sub-base with Ident. code E:

    � Connect the vacuum suction nozzle to work connection 4.

    � Connect work connections 2 and 4 together with tubing orwith the vacuum valve extension Ident. code V.

  • 3. Installation

    3-17Festo P.BE-CPV-EN en 1609i

    3.4.3 Connecting the electric cables

    Information on the connection procedure as well as on cablesand current requirements can be found in the manual P.BE-CPSYS-... “CP�system, installation and commissioning”.

    Warning� Only use PELV (protective extra-low voltage) circuits as

    per EN 60204-1 for the electric power supply.

    � Also observe the general requirements for PELV powercircuits as per EN 60204-1.

    � Only use power sources which guarantee reliableelectrical isolation of the operating voltage as per EN 60204-1.

    By the use of PELV power units, protection against electricshock (protection against direct and indirect contact) isguaranteed in accordance with EN 60204-1.

    NoteCheck within the framework of your EMERGENCY STOPcircuit, to ascertain the measures necessary for puttingyour machine/system into a safe state in the event of anEMERGENCY STOP (e.g. switching off the operating voltagefor the valves and output modules, switching off thecompressed air).

  • 3. Installation

    3-18 Festo P.BE-CPV-EN en 1609i

    Earthing the CPV valve terminal

    For earthing purposes, all variants of the CPV valve terminalhave an earthing connection. This is on the left-hand endplate (see diagram).

    1 Earth connection

    1

    Fig. 3/5: Earthing connections on the CPV valve terminal

    NoteEarth your CPV valve terminal.

    � Connect the earth connection on the left-hand end plate(see Fig. 3/5) with low impedance (short cable with largecross-sectional area) to the earth potential.

    � Tighten the earthing screw with max. 1 Nm.

    In this way, you will avoid interference caused byelectromagnetic influences.

  • 3. Installation

    3-19Festo P.BE-CPV-EN en 1609i

    Connecting current-consuming devices to therelay�plate

    Note� Use only ready-to-use connector sockets KRP-1-24-...

    from Festo for connecting current-consuming devices tothe relay outputs.

    Connect the current-consuming devices to the relay outputsas follows:

    � Carefully place the socket first on the terminal lug of thelower relay output (see figure).

    � Screw the socket together with the central locking screwwith 0.15 Nm.

    � Fit the second socket in the same way to the upper relayoutput.

    Fig. 3/6: Fitting the relay output sockets

  • 3. Installation

    3-20 Festo P.BE-CPV-EN en 1609i

    CPV valve terminal with IC connection

    With this CPV valve terminal variant each valve solenoid coil isconnected separately.

    Note� Use only the following ready-to-use sockets from Festo

    for connecting the valve solenoid coils:

    � for CPV10/14:NEBV-Z3WA2L-R-E-...-LE2-S1, an LED and the holdingcurrent reduction are incorporated in the transparentsocket. The LED indicates the switching status of thevalve solenoid coil.

    � for CPV18:KMEB-2-24-...-LED, an LED is incorporated in thetransparent socket. The LED indicates the switchingstatus of the valve solenoid coil.

    Address assignmentof the valves

    � The addresses must be assigned in ascending orderwithout gaps.

    � Counting begins from left to right, on the individual valveplates from the front to the rear (see Fig. 3/7).

    Fig. 3/7: Address assignment of a CPV valve terminal withIC connection and 8 valve locations

  • 3. Installation

    3-21Festo P.BE-CPV-EN en 1609i

    Connect the valve solenoid coils as follows:

    � Use connector socket NEBV-Z3WA2L-R-E-...-LE2-S1(CPV10/14) or KMEB-2-... (CPV18). Connector socketNEBV-Z3WA2L-R-E-...-LE2-S1 is fitted with current reduction.

    � Insert the socket onto the terminal lugs of the appropriatepilot solenoid (see figure). The socket can also be fittedturned 1800. Make sure that the centring bolt betweenthe terminal lugs grips into the hole in the socket. Screw the socket together with the central locking screwwith 0.15 Nm.

    Fig. 3/8: Fitting the individual connecting sockets

  • 3. Installation

    3-22 Festo P.BE-CPV-EN en 1609i

    CPV valve terminal with multipin, CPI or AS-Interfaceconnection

    Detailed information on fitting the electrical connections andon addressing can be found in the leaflet supplied with theproduct.

    CPV valve terminal with CP connection

    Detailed instructions on addressing and on the electricalinstallation of the CPV valve terminal can be found inchapter�1 “System summary” or in chapter 3 “Installation” ofthe manual P.BE-CPV-... “Installation and commissioningCP�systems”.

    CPV valve terminal with direct connection

    Detailed instructions on addressing and on the electricalinstallation of the CPV valve terminal with direct connectioncan be found in the appropriate manual “CPV valve terminalwith direct connection”.

  • Commissioning

    4-1Festo P.BE-CPV-EN en 1609i

    Chapter 4

    Commissioning

  • 4. Commissioning

    4-2 Festo P.BE-CPV-EN en 1609i

    Contents

    4. Commissioning 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.1 General instructions 4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.2 Testing the valves 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.2.1 Checking the valve functions 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4.2.2 Checking the valve-actuator combination 4-9. . . . . . . . . . . . . . . . . . . .

    4.3 Troubleshooting 4-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 4. Commissioning

    4-3Festo P.BE-CPV-EN en 1609i

    4.1 General instructions

    Before commissioning

    � Switch off the power supply before connecting or disconnecting plugs (otherwise this could lead to functionaldamage).

    � Earth the CPV valve terminal on the left-hand end plate.

    � Commission only a valve terminal which has been fittedand wired completely.

    � Make sure that there is a sufficient supply of fresh air(cooling) for the following operating conditions: – when the maximum number of valves are fitted– when the maximum operating voltage is applied– when the solenoid coils are constantly under stress.

    � If applicable, set the flow control valve extension or theone-way flow control valve extension.

    Note� When unscrewing the adjusting screw, make sure that

    you do not unscrew it beyond the resistance, as thiswould damage the cover.

    � The flow control valve extensions or one-way flowcontrol valve extensions (Ident. codes V, P and Q)require a minimum operating pressure of 0.5 bar.

  • 4. Commissioning

    4-4 Festo P.BE-CPV-EN en 1609i

    WarningIf the build-up in pressure of the pilot air is too slow ordelayed, this may cause the actuators to perform suddenunexpected movements under the following conditions:

    � when the compressed air is switched on with a safetystart-up valve (slow build up of pressure) and

    � if there are electric signals (e.g. after EMERGENCY STOP).

    This can cause damage to the machine or system and eveninjury to human beings.

    � Supply the pilot air separately via the right-hand endplate (3 … 8 bar).

    The pilot air must reach a pressure of 3 … 8 bar as soon as itis switched on, otherwise the valve cannot be guaranteed toswitch (see diagram). If the pressure is less than 3 bar, theremay be a delay before the valve is switched, in spite of anelectric signal being present. The slow increase in pressure ofthe complete supply does not then affect the cylinder.Depending on the valve function, the cylinder would extendor retract suddenly.

  • 4. Commissioning

    4-5Festo P.BE-CPV-EN en 1609i

    1

    4 2

    5 3

    14 12

    1

    2

    1

    12/14

    12/14

    3

    82/84

    2

    1 Externally supplied pilot air (3 … 8 bar), branched infront of the safety start-up valve

    2 Safety start-up valve (slow build up of pressure ofcomplete supply)

    Fig. 4/1: Example of valve-cylinder combination with slowincrease in pressure of the complete supply

    The table below shows the effects of slow start-up pressurization when there are electric signals.

    External pilotair supply

    Pressureincrease incomplete supply

    Pressure increasein the pilot air(12/14)

    Time pointwhen a valveswitches

    Movementof thecylinder

    branched afterthe safetystart-up valve

    slow slow after pressureincrease at (1)

    fast

    branched in frontof the safetystart-up valve

    slow fast before pressureincrease at (1)

    slow

    Tab. 4/1: Effects of slow start-up pressurization

  • 4. Commissioning

    4-6 Festo P.BE-CPV-EN en 1609i

    4.2 Testing the valves

    NoteBefore commissioning the CPV valve terminal, note thespecifications concerning the medium in chapter 3.

    The CPV valve terminal should be commissioned as follows:

    Commissioning variants Activity

    Preliminary test of thepneumatic tubing

    Checking the valve-actuatorcombination by means of themanual override (MO)

    Complete commissioningof�the complete system

    Installing and connecting thecomplete system Program control byPLC/industrial PC

    Tab. 4/2: Commissioning variants

    Commissioning the pneumatic components by means of themanual override is described below. Commissioning of theCP�system is described in the appropriate manual for theCP�node.

  • 4. Commissioning

    4-7Festo P.BE-CPV-EN en 1609i

    4.2.1 Checking the valve functions

    Manual override

    WarningBefore actuating the manual override:

    � Disconnect the power supply to the valve solenoid coilsof the relevant connections (IC, MP, AS-Interface, DI orCPI/CP connections). You will thereby avoid undesiredactuation of the valve solenoid coils.

    � Before switching on the power supply: make sure thatall manual override locking actuations are in their basicpositions. You will thereby avoid undefined switchingstates of the valves.

    You should use the manual override especially whencommissioning the pneumatic system, in order to check thefunction and operation of the valve or the valve-actuatorcombination.

    By actuating the manual override, you can switch the valvewithout an electric signal. You only need to switch on thecompressed air supply.

  • 4. Commissioning

    4-8 Festo P.BE-CPV-EN en 1609i

    Types of manual override

    The manual override has been designed to be used asfollows:

    Manual override design Method of operation

    Manual override with automatic return (non-locking)

    After actuation the manual overrideis reset by a spring.

    Manual override locking The manual override remains activeuntil it is reset by hand.

    Manual override covered The manual override is covered forsafety reasons. It cannot be actuated

    Tab. 4/3: Designs of manual override

    The diagram below shows the assignment of the manualoverrides to the pilot solenoids.

    Manual override locking Non-locking manual override

    1

    2

    3

    4

    1 Slide of the locking manual override topilot solenoid 14 (in basic position)

    2 Slide of the locking manual override topilot solenoid 12 (in basic position)

    3 Push button of non-locking manualoverride to pilot solenoid 14

    4 Push button of non-locking manualoverride to pilot solenoid 12

    Fig. 4/2: Assignment of manual overrides to the pilot solenoids

  • 4. Commissioning

    4-9Festo P.BE-CPV-EN en 1609i

    4.2.2 Checking the valve-actuator combination

    Carry out the test Proceed as follows:

    1. Switch on the compressed air supply.

    2. Check the functioning and effect of each valve-