TopicsTopics
Background
Goals
Screen and Display Design Injection/Machine Status Screen Machine Protection Screens Integrated Master Displays
Benefits and Future
Questions
www.lightsource.ca
BackgroundBackground
Operators need to monitor and control a number of processes, systems, devices, and equipments.
EPICS PVs (Process Variable) and EDM (Extended Display Manager) screens based on the PVs are created for this purpose.
The operation of the synchrotron is a complicated process. The numbers of PVs and EDM screens involved can be overwhelming
www.lightsource.ca
GoalsGoals
A quick and easy way to give the operator a snapshot of the machine status at one glance
A quick and easy way to navigate through different EDM screens
A quick and easy way to pin point each individual PV when necessary
A quick and easy way to locate the problematic component when a machine trip happens
A centralized location to put all involved PVs and screens together
www.lightsource.ca
Screen and Display DesignScreen and Display Design
Injection / Machine Status Screen
Machine Protection Screens
Integrated Master Displays
www.lightsource.ca
Injection/Machine Status Injection/Machine Status ScreenScreen
Grid status indicator matrix: How PVs are organized?Row : sub-systems
Column: key components
www.lightsource.ca
Injection/Machine Status Injection/Machine Status ScreenScreen
Indicator color definition: How status is represented?
www.lightsource.ca
Injection/Machine Status Injection/Machine Status ScreenScreen
Related displays - links to other EDM screens Indicator matrix - a snap shot of the big picture Sub-screens - display components info in a sub-system
Navigation through the Injection/Machine Status Screen:
www.lightsource.ca
Injection/Machine Status ScreenInjection/Machine Status Screen
Group Status: combine all component status together
A group status PV is created to indicate the collective status of a group of components in a sub-system.
The group status PV monitors all individual PVs in this group and calculates the combined status. Different algorithms are used for different types of PVs.
Eg. finds out the highest alarm level in the group and pass it to the group PV.
www.lightsource.ca
Injection/Machine Status ScreenInjection/Machine Status ScreenExample: pass highest alarm to the group PV
www.lightsource.ca
Machine Protection ScreensMachine Protection ScreensOverview of CLS Machine Protection Systems (MPS)
Tasks: monitors vacuum status using ion pumps, cold cathode gauges,
multi gauges, etc.
monitors device cooling status using flow switches, flow transmitters, thermo couples, RTDs, etc.
shuts down vacuum valves/photon shutters, disables Gun/ RF, for VACUUM PROTECTION/DEVICE PROTECTION when necessary
interface with other systems such as the personnel safety system, modulator controls, and other machine protection systems
Components of a typical MPS: a PLC system a hardware interlock system/a redundant PLC system
www.lightsource.ca
Machine Protection ScreensMachine Protection Screens
Machine Protection Screens:
display device status
provide operator controls
helps diagnose problem
www.lightsource.ca
Machine Protection ScreensMachine Protection ScreensExample: LINAC Machine Protection Screen
www.lightsource.ca
Machine Protection ScreensMachine Protection ScreensExample: Hard X-ray MicroAnalysis (HXMA) Frontend and Beamline Machine Protection Screen
www.lightsource.ca
Machine Protection ScreensMachine Protection Screens
Similarities to the Injection Status Screen:
Devices are organized into groups
Group status is represented by the color of its indicator
For some indicators, sub-screens can be brought up and displayed in an embedded window.
Related displays are provided when necessary to access more detailed information
www.lightsource.ca
Machine Protection ScreenMachine Protection ScreenBypass: Who got bypassed?
bypass indicator
regular indicator
www.lightsource.ca
Machine Protection ScreenMachine Protection Screen
Latch indicator: Who tripped the machine?
regular indicator
latch indicator
CLEAR LATCH
the component tripped the machine will be latched
latch indicators appear around the component indicator and its group indicator, and so on
latch indicators keeps showing until the latch is cleared even if the component status is GOOD
No new latch indicators will appear as long as the current latch is not cleared
www.lightsource.ca
Machine Protection ScreenMachine Protection ScreenLatch example:
www.lightsource.ca
Integrated Master DisplaysIntegrated Master Displays
The injection status screen and LINAC machine protection screen cover two important aspects of LINAC operation. However, they are not the only screens involved. There are also other screens such as the power supply status and vacuum status screens. A master display contains tabbed windows is therefore developed to integrate those screens into one single display.
Example: LINAC Master Display
www.lightsource.ca
Integrated Master DisplaysIntegrated Master DisplaysExample: LINAC Master Display
www.lightsource.ca
Integrated Master DisplaysIntegrated Master DisplaysExample: Beamline Master Display
www.lightsource.ca
Benefits Benefits
Simple , self-explanatory, and user friendly
Better organization of PVs and control screens
A handy tool to help identify problems
Shortened the average time taken to return the storage ring to service after a trip
www.lightsource.ca
FutureFuture
More indicators are to be added into the grid status indicator matrix as new devices are installed into the system
More screens are to be integrated into the master displays as the system evolves
Considering extend the indicator color key definition so that more status can be identified.
www.lightsource.ca
QuestionsQuestions
?