5
LM-79 Test Report LM79_ULTIMA_3000K_CRI80_8DEG CLS LED BV [email protected] www.cls-led.com 2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf General Discription Item number U-X-X-X-02-5 Date and time 17-2-2017 14:16:14 CCT (Kelvin) 2916 K Beam angle 11,2° Luminous flux 1889 lm Efficiency 104 lm/watt Weighted energy 18,1 kWh/1000h Power factor 0,89 CRI (RA) 83,7 Fidelity index Rf Rf 84,2 Gammut index Rg Rg 97,2

LM -79 - CLS LEDs light up your world!€¦ · LM -79 Test Report LM79_ULTIMA_3000K_CRI80_8DEG CLS LED BV info@cls -led.com -led.com

  • Upload
    others

  • View
    12

  • Download
    1

Embed Size (px)

Citation preview

Page 1: LM -79 - CLS LEDs light up your world!€¦ · LM -79 Test Report LM79_ULTIMA_3000K_CRI80_8DEG CLS LED BV info@cls -led.com  -led.com

LM-79 Test Report

LM79_ULTIMA_3000K_CRI80_8DEG

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

General Discription

Item number U-X-X-X-02-5

Date and time 17-2-2017 14:16:14

CCT (Kelvin) 2916 K

Beam angle 11,2°

Luminous flux 1889 lm

Efficiency 104 lm/watt

Weighted energy 18,1 kWh/1000h

Power factor 0,89

CRI (RA) 83,7

Fidelity index Rf Rf 84,2

Gammut index Rg Rg 97,2

Page 2: LM -79 - CLS LEDs light up your world!€¦ · LM -79 Test Report LM79_ULTIMA_3000K_CRI80_8DEG CLS LED BV info@cls -led.com  -led.com

LM-79 Test Report

LM79_ULTIMA_3000K_CRI80_8DEG

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

Beam details 1m 2m 3m 4m 5m

Lux* 34547 lx 8637 lx 3839 lx 2159 lx 1382 lx

11,2°

*measured at center of beam Footcandles* 3209,6 fcd 802,4 fcd 356,6 fcd 200,6 fcd 128,4 fcd

Beam width (meter) 0,2 m 0,4 m 0,6 m 0,8 m 1 m

Beam width (Feet) 0,6 ft 1,3 ft 1,9 ft 2,6 ft 3,2 ft

Beam intensities

1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 11m 12m 13m 14m 15m 16m 17m 18m 19m 20m

34547lx 8637lx 3839lx 2159lx 1382lx 960lx 705lx 540lx 427lx 345lx 286lx 240lx 204lx 176lx 154lx 135lx 120lx 107lx 96lx 86lx

3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 19,7ft 23ft 26,2ft 29,5ft 32,8ft 36,1ft 39,4ft 42,7ft 45,9ft 49,2ft 52,5ft 55,8ft 59,1ft 62,3ft 65,6ft

3209,6fcd

802,4fcd

356,6fcd

200,6fcd

128,4fcd

89,2fcd 65,5fcd 50,1fcd 39,6fcd 32,1fcd 26,5fcd 22,3fcd 19fcd 16,4fcd 14,3fcd 12,5fcd 11,1fcd 9,9fcd 8,9fcd 8fcd

Intensities in 0° c-plane

0° 1° 2° 3° 4° 5° 6° 7° 8° 9° 10° 11° 12° 13° 14° 15° 16° 17° 18° 19°

34,5K 31,4K 28,2K 24,9K 21,6K 18,4K 15,7K 12,9K 10,2K 7,4K 5,0K 4,1K 3,3K 2,4K 1,5K 0,9K 0,7K 0,6K 0,5K 0,3K

100% 91% 82% 72% 63% 53% 45% 37% 29% 21% 15% 12% 9% 7% 4% 3% 2% 2% 1% 1%

Intensities in 90° c-plane 0° 1° 2° 3° 4° 5° 6° 7° 8° 9° 10° 11° 12° 13° 14° 15° 16° 17° 18° 19°

34,5K 34,4K 31,0K 27,5K 24,1K 20,3K 16,7K 13,7K 10,7K 7,9K 6,1K 4,5K 3,5K 2,6K 1,7K 1,2K 0,8K 0,6K 0,5K 0,3K

100% 100% 90% 80% 70% 59% 48% 40% 31% 23% 18% 13% 10% 7% 5% 3% 2% 2% 1% 1%

Intensities in 180° c-plane 0° 1° 2° 3° 4° 5° 6° 7° 8° 9° 10° 11° 12° 13° 14° 15° 16° 17° 18° 19°

34,5K 31,4K 28,2K 24,9K 21,6K 18,4K 15,7K 12,9K 10,2K 7,4K 5,0K 4,1K 3,3K 2,4K 1,5K 0,9K 0,7K 0,6K 0,5K 0,3K

100% 91% 82% 72% 63% 53% 45% 37% 29% 21% 15% 12% 9% 7% 4% 3% 2% 2% 1% 1%

Intensities in 270° c-plane

0° 1° 2° 3° 4° 5° 6° 7° 8° 9° 10° 11° 12° 13° 14° 15° 16° 17° 18° 19°

34,5K 34,4K 31,0K 27,5K 24,1K 20,3K 16,7K 13,7K 10,7K 7,9K 6,1K 4,5K 3,5K 2,6K 1,7K 1,2K 0,8K 0,6K 0,5K 0,3K

100% 100% 90% 80% 70% 59% 48% 40% 31% 23% 18% 13% 10% 7% 5% 3% 2% 2% 1% 1%

Beam angle 50% Field angle 10% Cutoff angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

11,2° 23,9° {C_ANG}° 98,0% 97,4%

Page 3: LM -79 - CLS LEDs light up your world!€¦ · LM -79 Test Report LM79_ULTIMA_3000K_CRI80_8DEG CLS LED BV info@cls -led.com  -led.com

400 450 500 550 600 650 700 750 800

2200

K

2700

K30

00 K

3500

K40

00 K

5000

K60

00 K

7000

K

8000

K

9000

K

10000 K

450

460

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

76

Q1

95

Q2

85

Q3

82

Q4

85

Q5

85

Q6

85

Q7

89

Q8

95

Q9

91

Q10

89

Q11

86

Q12

85

Q13

73

Q14

74

Q15

79

C1

80

C2

76

C3

86

C4

90

C5

91

C6

83

C7

92

C8

89

C9

87

C10

84

C11

85

C12

88

C13

81

C14

81

C15

79

C16

82

R1

90

R2

98

R3

83

R4

82

R5

89

R6

85

R7

62

R8

14

R9

79

R10

82

R11

77

R12

83

R13

99

R14

74

R15

0,8

0,7

0,6

0,5

0,4

0,3

0,2

0,1

0,00,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7

2200

K

2700

K

3000

K

3500

K40

00 K

5000

K60

00 K

7000

K80

00 K

9000

K10

000 K

45046

0

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

LM-79 Test Report

LM79_ULTIMA_3000K_CRI80_8DEG

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

Color details

CIE 1931 x: 0,444 Spectra CIE 1931 ZOOM

2916 K y: 0,408 Δuv: 0,0007

CRI: 83,7 (R1-R8) CRI values, R1-R8 are used to calculate final CRI value

R1 R2 R3 R4 R5 R6 R7 R8

81,6 90,4 97,5 82,6 81,9 88,8 84,5 62,3

R9 R10 R11 R12 R13 R14 R15

14,4 78,7 82,1 77,4 83,4 98,8 74,2

CQS: 83,5 CQS values

Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8

75,9 95,2 85,1 82,4 84,6 85,0 85,3 88,6

Q9 Q10 Q11 Q12 Q13 Q14 Q15

95,4 91,2 88,6 86,4 84,9 73,1 73,8

TM30: 84,2 TM30 values, 16 binned values out of total of 99 values

C1 C2 C3 C4 C5 C6 C7 C8

79,4 80,1 75,9 85,5 90,0 90,6 83,0 91,9

C9 C10 C11 C12 C13 C14 C15

88,6 86,5 84,1 85,3 87,5 81,3 81,1

Color parameters Color

temperature Color rendering

index Red component Color fidelity Color gamut Color quality

scale Color coordinate

cie 1931 Color coordinate

cie 1931 Color

coordinate Color

coordinate Color diviation

from black body

CCT CRI CRI R9 TM30 Rf TM30 Rg CQS x y u v Δuv

2916 K 83,7 14,4 84,2 97,2 83,5 0,444 0,408 0,254 0,349 0,0007

Page 4: LM -79 - CLS LEDs light up your world!€¦ · LM -79 Test Report LM79_ULTIMA_3000K_CRI80_8DEG CLS LED BV info@cls -led.com  -led.com

-10% -8%-3%

4% 6% 4%0% -3%

-6% -6% -3%

4% 5% 4%-1%

-8%

79 8076

8690 91

8392 89 87 84 85 88

81 81 79

LM-79 Test Report

LM79_ULTIMA_3000K_CRI80_8DEG

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

TM30 details

Rf 84,2

Fidelity index Rf

Rg 97,2

Gammut index Rg

Hue binH Color vector graphics

Hue bin Color distortion graphics

Color Evaluation Sample

CES99

CES97

CES95

CES93

CES91

CES89

CES87

CES85

CES83

CES81

CES79

CES77

CES75

CES73

CES71

CES69

CES67

CES65

CES63

CES61

CES59

CES57

CES55

CES53

CES51

CES49

CES47

CES45

CES43

CES41

CES39

CES37

CES35

CES33

CES31

CES29

CES27

CES25

CES23

CES21

CES19

CES17

CES15

CES13

CES11

CES09

CES07

CES05

CES03

CES01

100

80

60

40

20

0 Fid

elit

y In

de

x, R

f

100

90

80

70

60

50

20% 15% 10%

5% 0%

-5% -10% -15% -20%

140

130

120

110

100

90

80

70

60

50 60 70 80 90 100

Rg

Rf

Graphic shifts (%)

Hue Bin Rf Chroma Hue

1 79 -10% -2%

2 80 -8% 7%

3 76 -3% 11%

4 86 4% 8%

5 90 6% 5%

6 91 4% -3%

7 83 0% -10%

8 92 -3% -3%

9 89 -6% -1%

10 87 -6% 4%

11 84 -3% 9%

12 85 4% 3%

13 88 5% -6%

14 81 4% -13%

15 81 -1% -11%

16 79 -8% -13%

Rf

by

hu

e

Ch

rom

a sh

ift

by

hu

e

Page 5: LM -79 - CLS LEDs light up your world!€¦ · LM -79 Test Report LM79_ULTIMA_3000K_CRI80_8DEG CLS LED BV info@cls -led.com  -led.com

LM-79 Test Report

LM79_ULTIMA_3000K_CRI80_8DEG

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

Glare Evaluation According to UGR

p Ceiling 70 70 50 50 30 70 70 50 50 30

p Walls 50 30 50 30 30 50 30 50 30 30

p Floor 20 20 20 20 20 20 20 20 20 20

Room size X Y

Viewing direction at right angles to lamp axis Viewing direction parallel to lamp axis

2H 2H 0,1 0,7 0,3 0,9 1,1 0,6 1,3 0,9 1,5 1,7

3H 0,6 1,2 0,9 1,5 1,7 1,3 1,9 1,6 2,2 2,4

4H 1,2 1,8 1,5 2,0 2,3 1,5 2,1 1,8 2,4 2,6

6H 3,2 3,7 3,5 4,0 4,3 3,0 3,5 3,4 3,8 4,1

8H 5,0 5,5 5,3 5,8 6,1 4,7 5,2 5,1 5,5 5,8

12H 7,2 7,7 7,6 8,0 8,3 6,7 7,1 7,0 7,4 7,8

4H 2H 0,3 0,8 0,6 1,1 1,4 0,8 1,4 1,1 1,6 1,9

3H 1,1 1,5 1,4 1,8 2,2 1,7 2,1 2,0 2,4 2,8

4H 1,9 2,3 2,3 2,7 3,1 2,0 2,4 2,4 2,8 3,2

6H 4,5 4,8 4,9 5,2 5,6 4,2 4,5 4,6 4,9 5,3

8H 6,6 6,9 7,1 7,3 7,7 6,3 6,6 6,7 7,0 7,4

12H 9,1 9,3 9,5 9,7 10,2 8,5 8,7 8,9 9,1 9,6

8H 4H 2,5 2,8 2,9 3,2 3,6 2,6 2,8 3,0 3,3 3,7

6H 5,7 5,9 6,2 6,4 6,8 5,4 5,6 5,9 6,1 6,6

8H 8,1 8,3 8,6 8,7 9,2 7,8 7,9 8,2 8,4 8,9

12H 10,7 10,9 11,2 11,3 11,9 10,2 10,3 10,7 10,8 11,3

12H 4H 2,9 3,1 3,3 3,5 4,0 3,0 3,2 3,4 3,6 4,1

6H 6,3 6,4 6,7 6,9 7,4 6,0 6,2 6,5 6,7 7,2

8H 8,7 8,9 9,2 9,4 9,9 8,5 8,6 9,0 9,1 9,6

Variation of the observer position for the luminaire distance S

S = 1,0H +0,2 / -0,3 +0,2 / -0,2

S = 1,5H +0,4 / -0,6 +0,4 / -0,6

S = 2,0H +0,5 / -0,9 +0,7 / -0,8

Standard table --- ---

Correction summand --- ---

Corrected glare indices referring to 1889lm total luminous flux

Color distortion graphics