CLAMP FOR TUBING OF CAPD BAG

ACCESSORY FOR CONTINUOUS AMBULATORY PERITONEAL DIALYSIS (CAPD)

Page 2: CLAMP FOR TUBING OF CAPD BAG · 2021. 5. 26. · 1. To open and close the PD uid in ll line and in drain line during exchange procedure. 2. Open clamp and place across the tubing

Use:

To support “Drain-Flush-Fill” step during CAPD procedure.

Items required:

Instructions for Use:

1. To open and close the PD uid in ll line and in drain line during

exchange procedure.

2. Open clamp and place across the tubing as per drawing.

a) Press it to stop uid ow in the tube as shown in g. 1.

b) Open it to allow uid ow as shown in g. 2.

3. Please follow CAPD exchange protocol.

4. Once the drainage is completed, close the transfer set line with clamp

as shown in Fig. 3.

5. Now open the blue tube clamp provided on the tubing the CAPD

solution bag and the connector and allow the new solution to ow into

the drainage container while you count from 1001 to 1005 slowly. This

is required to ush or remove any air in the primary tube as shown in

Fig. 4.

6. Close the drain tubing using the blue tube clamp.

7. Open the transfer set clamp and allow the infusion of CAPD solution

into the peritoneum as shown in Fig. 5.

8. At the completion of infusion, close the transfer set clamp and then the

blue tube clamp on the primary tubing. This will ensure that air does not

enter into peritoneum as shown in Fig. 6.

Fig. 1 Fig. 2

Tube Clamp Close Position Tube Clamp Open Position

CAPD Bag/Drain Tube

Fig. 4

Fig. 5

Fig. 6

Fill

Disconnection

• Face MaskSterile gloves• Disinfectant agent/Isopropyl Alcohol for hand washing• Tubing clamp•

*Spe

cic

atio

n/D

esig

ns a

re s

ubje

ct to

cha

nge

with

out a

ny o

blig

atio

n on

the

part

of

the

man

ufac

ture

r.

Drain

Closed

Open

Open

Fig. 3

Figure 6

Closed

Closed

Closed

Disconnection

Figure 5

Closed

Open

Open

Fill

Open

Figure 4

Open

Closed

Flush

Figure 3

Closed

Open

Open

Drain

Mitra Industries Private Limited 14/4, Delhi-Mathura Road, Faridabad, Haryana-121 003. INDIAT: +91-129-4099300 | Toll Free: 1800 1020 307 E: [email protected] | W: www.mitraindustries.com

Manufactured & Marketed by:YSTES M T CN EE RM TE IFG ICA AN TA E

M

IS 6O 1 01 234 5:8

A DNV GL COMPANY

Presafe

MIP

L-M

AR

/202

1

YSTES M T CN EE RM TE IFG ICA AN TA E

M

ISO 9001:2015

BUSINESS ASSURANCE

CT-

CL0

1, R

ev.:0

0