5
D D A B C C NOTES: NOTES: 9. ALL CRIMP FITTINGS TO 3/4" PEX TUBING REQUIRE 3/4" CLAMP 140171-05-000. 8. ALL CRIMP FITTINGS TO 1/2" PEX TUBING REQUIRE 1/2" CLAMP 140171-03-000. 7. ALL CRIMP FITTINGS TO 5/8" FLEX TUBING REQUIRE 5/8" CLAMP 140171-04-000. 6 LABEL HOT AND COLD SUPPLY TUBES AND TAPE FITTING TO TUBE BEFORE CABINET SET TO PREVENT MOVEMENT. 5 ADD PIPE WRAP (LADDER SCRAP 110157-02-000) INSULATION. 4 ADD TEFLON TAPE 010405-02-000. 3. ALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT. 2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO PROVIDE DRAINAGE TO NEAREST VALVE. 1. PLASTIC FITTINGS TO BE SEALED WITH SEALANT 084456-01-000. 79W REFRIGERATOR-4 DOOR 144 REFRIGERATOR-DOUBLE DOOR B D 6 3 ITEM/PART NO: 6 DESCRIPTION: 2 DFTR: WEIGHT: (LBS) 1 7 REF: 8 D DSNR: UNSPECIFIED TOLERANCES: ONE-PLACE (X.X) 5 B WHOLE DIM (X) COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. FIRST USED: (REF) 4 ANGLE A 1 2 C 3 MATERIAL: 8 A C SHEET: REV 5 4 7 ALL DIMENSIONS ARE IN MILLIMETERS TWO-PLACE (X.XX) REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES 1.5 0.50 1 3 WATER SYSTEM INSTL 1 OF 5 000173536 / 30055301000 REV ZONE REVISION RECORD DATE DFTR-ORIG A --- INITIAL RELEASE 10/05/15 3650-4378 FOR WATER CALLOUTS SEE DWG NO. 116230-01-000 X-X 19-Sep-2016

D D - WinnebagoALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT. 2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: D D - WinnebagoALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT. 2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO

D D

A

B

C

C

NOTES:NOTES:

9. ALL CRIMP FITTINGS TO 3/4" PEX TUBING REQUIRE 3/4" CLAMP 140171-05-000.

8. ALL CRIMP FITTINGS TO 1/2" PEX TUBING REQUIRE 1/2" CLAMP 140171-03-000.

7. ALL CRIMP FITTINGS TO 5/8" FLEX TUBING REQUIRE 5/8" CLAMP 140171-04-000.

6 LABEL HOT AND COLD SUPPLY TUBES AND TAPE FITTING TO TUBE BEFORE CABINET SET TO PREVENT MOVEMENT.

5 ADD PIPE WRAP (LADDER SCRAP 110157-02-000) INSULATION.

4 ADD TEFLON TAPE 010405-02-000.

3. ALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT.

2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO PROVIDE DRAINAGE TO NEAREST VALVE.

1. PLASTIC FITTINGS TO BE SEALED WITH SEALANT 084456-01-000.

79W REFRIGERATOR-4 DOOR

144 REFRIGERATOR-DOUBLE DOOR

B

D

6 3

ITEM/PART NO:

6

DESCRIPTION:

2

DFTR:

WEIGHT: (LBS)

1

7

REF:8

D

DSNR:

UNSPECIFIED TOLERANCES:

ONE-PLACE (X.X)

5

B

WHOLE DIM (X)

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

FIRST USED: (REF)

4

ANGLE

A

12

C

3

MATERIAL:

8

A

C

SHEET: REV

5

4

7

ALL DIMENSIONS ARE IN MILLIMETERS

TWO-PLACE (X.XX)

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

1.5

0.50

1

3

WATER SYSTEM INSTL

1 OF 5 000173536 / 30055301000

REV ZONE REVISION RECORD DATE DFTR-ORIG

A --- INITIAL RELEASE 10/05/15 3650-4378

FORWATER

CALLOUTSSEE DWG NO.

116230-01-000

X-X

19-Sep-2016

Page 2: D D - WinnebagoALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT. 2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO

TU-94700 TU10

4610

E-44E-44 V-11

T-28

V-6

V-6

E-44

TU-975

TU1090

4

4

TU10205

TU-965

VIEW A

SECTION D-D

FAUCET-LAV186417-01-CHT

R-46

6R-4

E-44

TU-81010

T-29T-29 TU-9

440

TU-92500

TU103050

WATER HEATER-INSTL186899-03-000CABLE076767-03-000SCREW000G39-08-08U (2)

T-29

TU1090

S-1

CLAMP-CLOSED010497-01-000CLAMP-CLOSED

010497-01-000

E-43

TU-92360

T-29

E-44

E-43

TU1055

TU-965

E-44

TU-5165V-24

CU-2

79W

144

S-1

A-282

S-1E-44

TU105650

W

W

SECTION W-W

TU-52400

S-1

BREAKER-VACUUM125697-04-000CHECK VALVE125697-03-000

TU-9990

T-28

TU-9180

E-46

79W

A-27

FILTER KIT-WATER,SINK160946-01-000

TU-9615

TU101455

FAUCET-GAL,SGL CNTL,HI SPOUT193458-01-CHT

000173536 / 300553010002 OF 5

WATER SYSTEM INSTL

8

1

A

2

58

6

D

REV

7

C

DESCRIPTION:

6

35

3

B

1

7

A

4

B

2

ITEM/PART NO:

D

C

4

SHEET:

OUTLET

INLET

19-Sep-2016

Page 3: D D - WinnebagoALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT. 2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO

4

TU102225

VIEW B

E-44

FAUCET-LAV186417-01-CHT

6

R-5 6

R-5

E-44

TU-8920

TO TOILET

TU-92095

T-28

CLAMP-CLOSED010497-01-000

TU102090

TU-92090

E-46

SECTION C-C

PANEL-SHOWER167738-02-CHT

436

1469

F-2

SH-1

T-28

E-43

TU-950

TU10130

DETAIL E

DETAIL E

E-44 4

TU-950

TU1050

TU1050

TU-9130

E-46

S-1S-1

S-1

A-27

BREAKER-VACUUM125697-04-000CHECK VALVE125697-03-000

TU-91880

TU102880

000173536 / 300553010003 OF 5

8

1

A

2

58

6

D

REV

7

C

DESCRIPTION:

6

35

3

B

1

7

A

4

B

2

ITEM/PART NO:

D

C

4

SHEET:

WATER SYSTEM INSTL

OUTLET

INLET

19-Sep-2016

Page 4: D D - WinnebagoALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT. 2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO

TANK ASM-WATER,74 GAL174701-04-000

1222

433

INSULATION-DRAINAGE COMPT168508-50-000

INSULATION-DRAINAGE COMPT168508-50-000

SHOWING ONLY TANKS AND DRAINS

STL-TUBE123963-34-CHT

F697

INSULATION-DRAINAGE COMPT168508-50-000

DATUM

5682

248

BRACKET-ANGLE,W/HOLES094756-02-CHT

INSULATION-DRAINAGE COMPT168508-32-000(2)

VIEW F

PANEL-SERVICE CENTER146164-11-CHT

F-2

SH-1

PANEL-SERVICE CENTER146163-06-CHT

F-14

PANEL-SERVICE CENTER146163-14-CHT

A-4

CLIP-GRIPPER091952-03-000

CI-3

A-5

TU-41600

CH-2

KK

SECTION K-K

600

45

15

G

CH-82

WATER FILL131081-04-XXX

FLUSHING SYSTEM125697-05-000

V-23

S-1

TU15555

TU-970 SCREW

000G60-08-12U

PANEL-SERVICE CENTER146164-14-CHT

E-44

TU-3700

FLUSHING SYSTEM125697-05-000

000173536 / 300553010004 OF 5

8

1

A

2

58

6

D

REV

7

C

DESCRIPTION:

6

35

3

B

1

7

A

4

B

2

ITEM/PART NO:

D

C

4

SHEET:

WATER SYSTEM INSTL

19-Sep-2016

Page 5: D D - WinnebagoALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT. 2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO

E-44

CLAMP010497-10-000SCREW000G11-10-12U

T-29

TU-985

F-5 TU-9180

TU-980

TU-9335

TU-995

T-28

E-44

A-28

TU-970

E-43

A-28

TU-9110

T-29

TU-9100

TU-970

TU-955

E-46

E-43

A-27

V-11

TU-985

E-43

TU-8175

CLAMP010495-04-000RIVET113133-03-CHT

BRACKET-PUMP,WATER169229-01-CHTPANEL-WATER PUMP149477-08-CHTFOAM-PAD140364-01-CHT

TU-970

F-9

TU-9435

TU-9 50

E-43

E-43

PW-5

TU-9320

TU-8240

TU15250

TU-9105

E-48

TU-940

A-28

CH-2

E-43

E-44

E-43

V-10

E-44

VIEW G

DETAIL H(SHOWN W/OUT WATER FILL TUBE)

DETAIL H

DETAIL J

DETAIL J E-43

TU15210

T-28

A-28

E-28

E-43

V-21

TU-9120

TU-9 60

CU-2

TU-945

E-44

TU-940

000173536 / 300553010005 OF 5

WATER SYSTEM INSTL

8

1

A

2

58

6

D

REV

7

C

DESCRIPTION:

6

35

3

B

1

7

A

4

B

2

ITEM/PART NO:

D

C

4

SHEET:

19-Sep-2016