Claims taken from BLP’s website regarding CIHT
This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims.Includes claims, data and independent validation reports.
Blacklight Power’s website is:http://www.blacklightpower.com
Claims taken from BLP’s website regarding CIHT
Regarding CIHT data shown in next two slides:
Energy input = 5 mA for 0.4 Seconds at an average of 0.79 Volts.Energy output = 5 mA for 4.1 Seconds at an average of 0.78 Volts
Power input = (Duty cycle)*(Volts)*(Current) = (0.4/4.5)*(0.005)*(0.79) = 0.351 mW Power Output = (Duty Cycle)*(Volts)*(Current) = (4.1/4.5)*(0.005)*(0.78) = 3.55 mW
Ratio = Output/Input = 3.55/0.351 = 11.2
Gain = (100%)*(Output/Input) = (100%)*(3.55/0.351)= 1120%
Output and input current could be measured using the exact same 1 ohm resistor (volts across resistor would be 0.005 V).Voltage across the cell remains fairly constant at 0.78 to 0.79 Volts.Total error for power measurements can easily be less than 3% with good equipment.
Claims taken from BLP’s website regarding CIHT
Curr
ent
Data taken from BLP’s report on CIHT results.
Claims taken from BLP’s website regarding CIHT
Volta
ge
Data taken from BLP’s report on CIHT results.
Claims taken from BLP’s website regarding CIHT
http://www.blacklightpower.com/technology/ciht-cell/
http://www.blacklightpower.com/faq/
10 W unit has been tested
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/business/business-summary
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
Output energy 2000 times the input
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
11
BLP CIHT results of energy output and gain.
5000% gain;Output is 50X input here.
10000%
1000%
10%
100%
source:http://blacklightpower.com/wp-content/uploads/presentations/TechnicalPresentation.pdf
For example, at 100% Energy Gain, output is equal to input.66 days
Energy Gain
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/technology/validation-reports
6 teams/individuals from relevent industries wrote validation reports on CIHT
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/WeinbergReport.pdf
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/CopelandReport.pdf
5476% gain means that the output is 54 times larger than the input
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/F500Study.pdf
200,000% gain means that the output is 2000 times larger than the input
Claims taken from BLP’s website regarding CIHT
242,132% gain means that the output is 2421 times larger than the input
286% gain means that the output is 2.8 times larger than the input
Claims taken from BLP’s website regarding CIHT
500% gain means that the output is 5 times larger than the input
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/RamanujacharyReport.pdf
735% gain means that the output is 7.3 times larger than the input
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/GlumacReport.pdf
2400 ratio of output to input !
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/ENSERReport.pdf
144028% gain means that the output is 1440 times larger than the input
Claims taken from BLP’s website regarding CIHT