17
S SERIES 1. SPECIFICATIONS S-2 2. CAPACITY TABLES S-6 2.1 Correction by temperature S-6 2.2 Correction by total indoor S-8 2.3 Correction by refrigerant piping length S-10 2.4 Correction at frosting and defrosting S-11 2.5 Temp. range of running S-11 3. SOUND LEVELS S-12 4. EXTERNAL DIMENSIONS S-13 5. ELECTRICAL WIRING DIAGRAMS S-15 6. REFRIGERANT CIRCUIT DIAGRAMS AND THERMAL SENSORS S-17 CITY MULTI™ S SERIES OUTDOOR UNITS Heat pump: PUMY-P-YHM 5HP 6HP 4HP S Heat pump 3-phase 4-wire 380-400-415V/50Hz 100 125 140 Heat pump: PUMY-P-VHM 5HP 6HP 4HP S Heat pump 1-phase 2-wire 220-230-240V/50Hz 220V/60Hz 100 125 140 Large Residents Small Offices VI S SERIES OUTDOOR UNIT R410A S - 1 R410A Data G3 Y WY R2 WR2 S OP

CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

S SERIES1. SPECIFICATIONS S-22. CAPACITY TABLES S-6

2.1 Correction by temperature S-62.2 Correction by total indoor S-82.3 Correction by refrigerant piping length S-102.4 Correction at frosting and defrosting S-112.5 Temp. range of running S-11

3. SOUND LEVELS S-124. EXTERNAL DIMENSIONS S-135. ELECTRICAL WIRING DIAGRAMS S-156. REFRIGERANT CIRCUIT DIAGRAMS AND THERMAL SENSORS S-17

CITY MULTI™ S SERIESOUTDOOR UNITS

Heat pump: PUMY-P-YHM

5HP 6HP4HP

S Heat pump

3-phase 4-wire380-400-415V/50Hz

100 125 140

● ● ●

Heat pump: PUMY-P-VHM

5HP 6HP4HP

S Heat pump

1-phase 2-wire220-230-240V/50Hz220V/60Hz

100 125 140

● ● ●

Large Residents

Small Offices

VI S SERIES

OUTDOOR UNIT R410A S - 1

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 2: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

R410A S - 2

R410A Data G3

Y

WY

R2

WR2

S

OP

OUTDOOR UNIT

Galvanized steel sheet<MUNSELL 3Y 7.8/1.1>

MITSUBISHI ELECTRIC CORPORATIONInverter

-High pressure sensor, High pressure switch 4.15 MPa

Over-heat protection, Over-current protectionDischarge thermo protection, Over-current protection

Over-heat protection, Voltage protectionAuto-defrost mode (Reversed refrigerant circle)

LEV circuit

Installation ManualGrounded lead wire x 2

Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.

YHM-BK01-B328YHM-RG79-V020RC_VBN-050092

PUMY-P100YHM PUMY-P125YHM

3-phase 4-wire 380-400-415V 50Hz

15 ~ 24˚C (59 ~ 75˚F)- 5 ~ 46˚C (23 ~ 115˚F)

10 to 46˚CD.B. (50 to 115˚FD.B.) : in case of connecting PKFY-P20/P25 type indoor unit.

15 ~ 27˚C (59 ~ 81˚F)-15 ~ 15˚C (5 ~ 59˚F)

50 ~ 130% of outdoor unit capacity

11.2 9,600

38,200 -

3.305.28-5.02-4.84

3.39

12.510,80042,7003.63

5.81-5.52-5.323.44

P20 ~ P125 / 1 ~ 649 / 51

ø9.52 (ø3/8") Flare

ø15.88 (ø5/8") Flare

14.0 12,00047,80012,5004.27

6.83-6.49-6.263.28

16.0 13,80054,6004.29

6.87-6.52-6.293.73

P20 ~ P140 / 1 ~ 850 / 52

ø9.52 (ø3/8") Flare

ø15.88 (ø5/8") Flare

1,350 x 950 x 33053-3/16" x 37-7/16" x 13"

140 (309)Salt-resistant cross fin & copper tube

Inverter scroll hermetic comp.

1.9-

MEL56100

166735320 Pa

Propeller fan x 2DC-control, Direct-driven by motor

0.06 x 2

R410A x 8.5kg (19 lb)

Joint: CMY-Y62-G-EHeader:CMY-Y64/68-G-E

1,350 x 950 x 33053-3/16" x 37-7/16" x 13"

140 (309)Salt-resistant cross fin & copper tube

Inverter scroll hermetic comp.

2.4-

MEL56100

166735320 Pa

Propeller fan x 2DC-control, Direct-driven by motor

0.06 x 2

R410A x 8.5kg (19 lb)

Joint: CMY-Y62-G-EHeader:CMY-Y64/68-G-E

Ref. : Spec_s_p100_125YHM

✻1 Nominal cooling conditionsNote :

Indoor :Outdoor :

Pipe length :Level difference :

27˚CDB/19˚CWB (81˚FDB/66˚FWB)35˚CDB (95˚FDB)7.5 m (24-9/16 ft)0 m (0 ft)

✻2 Nominal cooling conditions

27˚CDB/19.5˚CWB (81˚FDB/67˚FWB)35˚CDB (95˚FDB)5 m (16-3/8 ft)0 m (0 ft)

✻3 Nominal heating conditions Unit converter

20˚CDB (68˚FDB)7˚CDB/6˚CWB (45˚FDB/43˚FWB)7.5 m (24-9/16 ft)0 m (0 ft)

* Nominal conditions ✻1, ✻3 are subject to JIS B8615-1.* Due to continuing improvement, above specifications may be subject to change without notice.

kcal/h = kW x 860Btu/h = kW x 3,412cfm = m3/min x 35.31lb = kg / 0.4536

*Above specification data is subject to rounding variation.

Model

Power sourceCooling capacity (Nominal)

Temp. range of cooling

Heating capacity(Nominal )

Temp. range of heating

Indoor unitconnectableNoise level (measured in anechoic room)

Diameter of refrigerant pipe

External finish

External dimension H x W x D

Net weightHeat exchangerCompressor

FAN

HIC circuit (HIC: Heat Inter-Changer)

Protection

Defrosting methodRefrigerant

Drawing

Standard attachmentOptional parts

Remark

Power inputCurrent inputCOP (kW / kW)Indoor Outdoor

Power inputCurrent inputCOP (kW / kW) Indoor temp. Outdoor temp.

Total capacityModel / Quantity

Liquid (High press.)

Gas (Low press.)

TypeManufacturerStarting methodMotor outputCase heaterLubricantAir flow rate

External static press.Type x QuantityControl, Driving mechanismMotor output

High pressure protectionInverter circuit (COMP. / FAN)CompressorFan motor

Type x Original chargeControlExternalWiringRefrigerant circleDocumentAccessory

kWkcal / hBtu / hkcal / hkWA

W.B.D.B.

kWkcal / hBtu / hkWA

D.B.W.B.

dB <A>mm (in.)

mm (in.)

mmin.kg (lb)

kWkW

m3 / minL / scfm

kW

✻1

✻1

✻1

✻2

✻3

✻3

✻3

1. SPECIFICATIONS

Page 3: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

✻1 Nominal cooling conditionsNote :

Indoor :Outdoor :

Pipe length :Level difference :

27˚CDB/19˚CWB (81˚FDB/66˚FWB)35˚CDB (95˚FDB)7.5 m (24-9/16 ft)0 m (0 ft)

✻2 Nominal cooling conditions

27˚CDB/19.5˚CWB (81˚FDB/67˚FWB)35˚CDB (95˚FDB)5 m (16-3/8 ft)0 m (0 ft)

✻3 Nominal heating conditions Unit converter

20˚CDB (68˚FDB)7˚CDB/6˚CWB (45˚FDB/43˚FWB)7.5 m (24-9/16 ft)0 m (0 ft)

* Nominal conditions ✻1, ✻3 are subject to JIS B8615-1.* Due to continuing improvement, above specifications may be subject to change without notice.

kcal/h = kW x 860Btu/h = kW x 3,412cfm = m3/min x 35.31lb = kg / 0.4536

*Above specification data is subject to rounding variation.

Model

Power sourceCooling capacity (Nominal)

Temp. range of cooling

Heating capacity(Nominal )

Temp. range of heating

Indoor unitconnectableNoise level (measured in anechoic room)

Diameter of refrigerant pipe

External finish

External dimension H x W x D

Net weightHeat exchangerCompressor

FAN

HIC circuit (HIC: Heat Inter-Changer)

Protection

Defrosting methodRefrigerant

Drawing

Standard attachmentOptional parts

Remark

Power inputCurrent inputCOP (kW / kW)Indoor Outdoor

Power inputCurrent inputCOP (kW / kW) Indoor temp. Outdoor temp.

Total capacityModel / Quantity

Liquid (High press.)

Gas (Low press.)

TypeManufacturerStarting methodMotor outputCase heaterLubricantAir flow rate

External static press.Type x QuantityControl, Driving mechanismMotor output

High pressure protectionInverter circuit (COMP. / FAN)CompressorFan motor

Type x Original chargeControlExternalWiringRefrigerant circleDocumentAccessory

kWkcal / hBtu / hkcal / hkWA

W.B.D.B.

kWkcal / hBtu / hkWA

D.B.W.B.

dB <A>mm (in.)

mm (in.)

mmin.kg (lb)

kWkW

m3 / minL / scfm

kW

✻1

✻1

✻1

✻2

✻3

✻3

✻3

1. SPECIFICATIONS

OUTDOOR UNIT R410A S - 3

R410A Data G3

Y

WY

R2

WR2

S

OP

Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.

Galvanized steel sheet<MUNSELL 3Y 7.8/1.1>

MITSUBISHI ELECTRIC CORPORATIONInverter

-High pressure sensor, High pressure switch 4.15 MPa

Over-heat protection, Over-current protectionDischarge thermo protection, Over-current protection

Over-heat protection, Voltage protectionAuto-defrost mode (Reversed refrigerant circle)

LEV circuit

Installation ManualGrounded lead wire x 2

YHM-BK01-B328YHM-RG79-V020RC_VBN-050092

PUMY-P140YHM

3-phase 4-wire 380-400-415V 50Hz

15 ~ 24˚C (59 ~ 75˚F)- 5 ~ 46˚C (23 ~ 115˚F)

10 to 46˚CD.B. (50 to 115˚FD.B.) : in case of connecting PKFY-P20/P25 type indoor unit.

15 ~ 27˚C (59 ~ 81˚F)-15 ~ 15˚C (5 ~ 59˚F)

50 ~ 130% of outdoor unit capacity

15.513,30052,90014,0005.32

8.51-8.09-7.802.91

18.015,50061,4005.32

8.51-8.09-7.803.38

P20 ~ P140 / 1 ~ 851 / 53

ø9.52 (ø3/8") Flare

ø15.88 (ø5/8") Flare

1,350 x 950 x 33053-3/16" x 37-7/16" x 13"

140 (309)Salt-resistant cross fin & copper tube

Inverter scroll hermetic comp.

2.9-

MEL56100

166735320 Pa

Propeller fan x 2DC-control, Direct-driven by motor

0.06 x 2

R410A x 8.5kg (19 lb)

Joint: CMY-Y62-G-EHeader:CMY-Y64/68-G-E

Ref. : Spec_s_p140YHM

Page 4: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

Galvanized steel sheet<MUNSELL 3Y 7.8/1.1>

MITSUBISHI ELECTRIC CORPORATIONInverter

-High pressure sensor, High pressure switch 4.15 MPa

Over-heat protection, Over-current protectionDischarge thermo protection, Over-current protection

Over-heat protection, Voltage protectionAuto-defrost mode (Reversed refrigerant circle)

LEV circuit

Installation ManualGrounded lead wire x 2

In case of connecting All fresh air type indoor unit PEFY-P-VHM-E-F, only one indoor unit can be connected with one PUMY.Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.

PUMY-P100VHM PUMY-P125VHM

VHM-BK01-B434VHM-RG79-V221RC_VBN-050092

Ref. : Spec_s_p100_125VHM

1-phase 220-230-240V 50Hz, 1-phase 220V 60Hz

15 ~ 24˚C (59 ~ 75˚F)- 5 ~ 46˚C (23 ~ 115˚F)

10 to 46˚CD.B. (50 to 115˚FD.B.) : in case of connecting PKFY-P20 / P25 type indoor unit.

15 ~ 27˚C (59 ~ 81˚F)-15 ~ 15˚C (5 ~ 59˚F)

50 ~ 130% of outdoor unit capacity

11.29,600

38,20010,0003.34

15.4-14.8-14.1, 15.43.35

12.510,80042,7003.66

16.9-16.2-15.5, 16.93.42

P20 ~ P125 / 1 ~ 649 / 51

ø9.52 (ø3/8") Liquid

ø15.88 (ø5/8") Gas

14.012,00047,80012,5004.32

20.0-19.1-18.3, 20.03.24

16.013,80054,6004.33

20.0-19.1-18.3, 20.03.69

P20 ~ P140 / 1 ~ 850 / 52

ø9.52 (ø3/8") Liquid

ø15.88 (ø5/8") Gas

1,350 x 950 x 33053-3/16" x 37-7/16" x 13"

127 (280 lb)Salt-resistant cross fin & copper tube

Inverter scroll hermetic comp.

2.2-

MEL56 x 2.3 L100

166735320 Pa

Propeller fan x 2DC-control, Direct-driven by motor

0.06 x 2

R410A x 8.5kg (19 lb)

Joint: CMY-Y62-G-EHeader:CMY-Y64/68-G-E

1,350 x 950 x 33053-3/16" x 37-7/16" x 13"

127 (280 lb)Salt-resistant cross fin & copper tube

Inverter scroll hermetic comp.

2.9-

MEL56 x 2.3 L100

166735320 Pa

Propeller fan x 2DC-control, Direct-driven by motor

0.06 x 2

R410A x 8.5kg (19 lb)

Joint: CMY-Y62-G-EHeader:CMY-Y64/68-G-E

✻1 Nominal cooling conditionsNote :

Indoor :Outdoor :

Pipe length :Level difference :

27˚CDB/19˚CWB (81˚FDB/66˚FWB)35˚CDB (95˚FDB)7.5 m (24-9/16 ft)0 m (0 ft)

✻2 Nominal cooling conditions

27˚CDB/19.5˚CWB (81˚FDB/67˚FWB)35˚CDB (95˚FDB)5 m (16-3/8 ft)0 m (0 ft)

✻3 Nominal heating conditions Unit converter

20˚CDB (68˚FDB)7˚CDB/6˚CWB (45˚FDB/43˚FWB)7.5 m (24-9/16 ft)0 m (0 ft)

* Nominal conditions ✻1, ✻3 are subject to JIS B8615-1.* Due to continuing improvement, above specifications may be subject to change without notice.

kcal/h = kW x 860Btu/h = kW x 3,412cfm = m3/min x 35.31lb = kg / 0.4536

*Above specification data is subject to rounding variation.

Model

Power sourceCooling capacity (Nominal)

Temp. range of cooling

Heating capacity(Nominal )

Temp. range of heating

Indoor unitconnectableNoise level (measured in anechoic room)

Diameter of refrigerant pipe

External finish

External dimension H x W x D

Net weightHeat exchangerCompressor

FAN

HIC circuit (HIC: Heat Inter-Changer)

Protection

Defrosting methodRefrigerant

Drawing

Standard attachmentOptional parts

Remark

Power inputCurrent inputCOP (kW / kW)Indoor Outdoor

Power inputCurrent inputCOP (kW / kW) Indoor temp. Outdoor temp.

Total capacityModel / Quantity

Liquid (High press.)

Gas (Low press.)

TypeManufacturerStarting methodMotor outputCase heaterLubricantAir flow rate

External static press.Type x QuantityControl, Driving mechanismMotor output

High pressure protectionInverter circuit (COMP. / FAN)CompressorFan motor

Type x Original chargeControlExternalWiringRefrigerant circleDocumentAccessory

kWkcal / hBtu / hkcal / hkWA

W.B.D.B.

kWkcal / hBtu / hkWA

D.B.W.B.

dB <A>mm (in.)

mm (in.)

mmin.kg (lb)

kWkW

m3 / minL / scfm

kW

✻1

✻1

✻1

✻2

✻3

✻3

✻3

1. SPECIFICATIONS

OUTDOOR UNIT R410A S - 4

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 5: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

Galvanized steel sheet<MUNSELL 3Y 7.8/1.1>

MITSUBISHI ELECTRIC CORPORATIONInverter

-High pressure sensor, High pressure switch 4.15 MPa

Over-heat protection, Over-current protectionDischarge thermo protection, Over-current protection

Over-heat protection, Voltage protectionAuto-defrost mode (Reversed refrigerant circle)

LEV circuit

Installation ManualGrounded lead wire x 2

In case of connecting All fresh air type indoor unit PEFY-P-VHM-E-F, only one indoor unit can be connected with one PUMY.Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.

PUMY-P140VHM

1-phase 220-230-240V 50Hz, 1-phase 220V 60Hz

15 ~ 24˚C (59 ~ 75˚F)- 5 ~ 46˚C (23 ~ 115˚F)

10 to 46˚CD.B. (50 to 115˚FD.B.) : in case of connecting PKFY-P20/P25 type indoor unit.

15 ~ 27˚C (59 ~ 81˚F)-15 ~ 15˚C (5 ~ 59˚F)

50 ~ 130% of outdoor unit capacity

15.513,30052,90014,0005.35

24.7-23.6-22.7, 24.72.9

18.015,50061,4005.58

25.8-24.7-23.6, 25.83.23

P20 ~ P140 / 1 ~ 851 / 53

ø9.52 (ø3/8") Liquid

ø15.88 (ø5/8") Gas

1,350 x 950 x 33053-3/16" x 37-7/16" x 13"

127 (280 lb)Salt-resistant cross fin & copper tube

Inverter scroll hermetic comp.

3.3-

MEL56 x 2.3L100

166735320 Pa

Propeller fan x 2DC-control, Direct-driven by motor

0.06 x 2

R410A x 8.5kg (19 lb)

Joint: CMY-Y62-G-EHeader:CMY-Y64/68-G-E

VHM-BK01-B434VHM-RG79-V221RC_VBN-050092

Ref. : Spec_s_p140VHM

✻1 Nominal cooling conditionsNote :

Indoor :Outdoor :

Pipe length :Level difference :

27˚CDB/19˚CWB (81˚FDB/66˚FWB)35˚CDB (95˚FDB)7.5 m (24-9/16 ft)0 m (0 ft)

✻2 Nominal cooling conditions

27˚CDB/19.5˚CWB (81˚FDB/67˚FWB)35˚CDB (95˚FDB)5 m (16-3/8 ft)0 m (0 ft)

✻3 Nominal heating conditions Unit converter

20˚CDB (68˚FDB)7˚CDB/6˚CWB (45˚FDB/43˚FWB)7.5 m (24-9/16 ft)0 m (0 ft)

* Nominal conditions ✻1, ✻3 are subject to JIS B8615-1.* Due to continuing improvement, above specifications may be subject to change without notice.

kcal/h = kW x 860Btu/h = kW x 3,412cfm = m3/min x 35.31lb = kg / 0.4536

*Above specification data is subject to rounding variation.

Model

Power sourceCooling capacity (Nominal)

Temp. range of cooling

Heating capacity(Nominal )

Temp. range of heating

Indoor unitconnectableNoise level (measured in anechoic room)

Diameter of refrigerant pipe

External finish

External dimension H x W x D

Net weightHeat exchangerCompressor

FAN

HIC circuit (HIC: Heat Inter-Changer)

Protection

Defrosting methodRefrigerant

Drawing

Standard attachmentOptional parts

Remark

Power inputCurrent inputCOP (kW / kW)Indoor Outdoor

Power inputCurrent inputCOP (kW / kW) Indoor temp. Outdoor temp.

Total capacityModel / Quantity

Liquid (High press.)

Gas (Low press.)

TypeManufacturerStarting methodMotor outputCase heaterLubricantAir flow rate

External static press.Type x QuantityControl, Driving mechanismMotor output

High pressure protectionInverter circuit (COMP. / FAN)CompressorFan motor

Type x Original chargeControlExternalWiringRefrigerant circleDocumentAccessory

kWkcal / hBtu / hkcal / hkWA

W.B.D.B.

kWkcal / hBtu / hkWA

D.B.W.B.

dB <A>mm (in.)

mm (in.)

mmin.kg (lb)

kWkW

m3 / minL / scfm

kW

✻1

✻1

✻1

✻2

✻3

✻3

✻3

1. SPECIFICATIONS

OUTDOOR UNIT R410A S - 5

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 6: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

2. CAPACITY TABLES2-1. Correction by temperature

CITY MULTI TM could have varied capacity at different designing temperature. Using the nominal cooling/heating capacity value and the ratio below, the capacity can be observed at various temperature.

Ratio of cooling capacity and power input Outdoor temperature

Ratio of heating capacity and power input Outdoor temperature

-5 0 5 10 15 20 25 30 35 40 4523 32 41 50 59 68 77 86 95 104 113

˚CDB˚FDB

1.2

1.1

1.0

0.8

0.9

0.7

0.6

0.5

0.4

Rat

io o

f p

ow

er in

pu

t

-20-4

-155

-1014

-523

032

541

1050

1559

˚CWB˚FWB

0.6

1.0

0.8

0.9

0.7

0.6

0.5

0.4

Rat

io o

f p

ow

er in

pu

t

1.4

1.3

1.1

1.0

0.9

1.2

Rat

io o

f co

olin

g c

apac

ity

Indoor Temperature

22˚CWB72˚FWB

20˚CWB68˚FWB

18˚CWB64˚FWB

16˚CWB61˚FWB

22˚CWB72˚FWB

20˚CWB68˚FWB

18˚CWB64˚FWB

16˚CWB61˚FWB

1.3

1.2

1.0

0.9

0.8

0.7

1.1

Rat

io o

f h

eati

ng

cap

acit

y

15˚CDB59˚FDB

20˚CDB68˚FDB

25˚CDB77˚FDB

15˚CDB59˚FDB

20˚CDB68˚FDB

25˚CDB77˚FDB

Indoor Temperature

NominalCoolingCapacity

Input

kW

kcal/h

Btu/h

kW

NominalCoolingCapacity

Input

kW

kcal/h

Btu/h

kW

NominalHeatingCapacity

Input

kW

kcal/h

Btu/h

kW

NominalHeatingCapacity

Input

kW

kcal/h

Btu/h

kW

PUMY- P100YHM P125YHM11.2

9,600

38,200

3.30

14.0

12,000

47,800

4.27

PUMY- P140YHM15.5

13,300

52,900

5.32

PUMY- P100YHM P125YHM12.5

10,800

42,700

3.63

16.0

13,800

54,600

4.29

PUMY- P140YHM18.0

15,500

61,400

5.32

Ref:cbt_p100-140

OUTDOOR UNIT R410A S - 6

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 7: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

2. CAPACITY TABLES2-1. Correction by temperature

CITY MULTI TM could have varied capacity at different designing temperature. Using the nominal cooling/heating capacity value and the ratio below, the capacity can be observed at various temperature.

Ratio of cooling capacity and power input Outdoor temperature

Ratio of heating capacity and power input Outdoor temperature

-5 0 5 10 15 20 25 30 35 40 4523 32 41 50 59 68 77 86 95 104 113

˚CDB˚FDB

1.2

1.1

1.0

0.8

0.9

0.7

0.6

0.5

0.4

Rat

io o

f p

ow

er in

pu

t

-20-4

-155

-1014

-523

032

541

1050

1559

˚CWB˚FWB

0.6

1.0

0.8

0.9

0.7

0.6

0.5

0.4

Rat

io o

f p

ow

er in

pu

t

1.4

1.3

1.1

1.0

0.9

1.2

Rat

io o

f co

olin

g c

apac

ity

Indoor Temperature

22˚CWB72˚FWB

20˚CWB68˚FWB

18˚CWB64˚FWB

16˚CWB61˚FWB

22˚CWB72˚FWB

20˚CWB68˚FWB

18˚CWB64˚FWB

16˚CWB61˚FWB

1.3

1.2

1.0

0.9

0.8

0.7

1.1

Rat

io o

f h

eati

ng

cap

acit

y

15˚CDB59˚FDB

20˚CDB68˚FDB

25˚CDB77˚FDB

15˚CDB59˚FDB

20˚CDB68˚FDB

25˚CDB77˚FDB

Indoor Temperature

NominalCoolingCapacity

Input

kW

kcal/h

Btu/h

kW

NominalCoolingCapacity

Input

kW

kcal/h

Btu/h

kW

NominalHeatingCapacity

Input

kW

kcal/h

Btu/h

kW

NominalHeatingCapacity

Input

kW

kcal/h

Btu/h

kW

PUMY- P100VHM P125VHM11.2

9,600

38,200

3.34

14.0

12,000

47,800

4.32

PUMY- P140VHM15.5

13,300

52,900

5.35

PUMY- P100VHM P125VHM12.5

10,800

42,700

3.66

16.0

13,800

54,600

4.33

PUMY- P140VHM18.0

15,500

61,400

5.58

Ref:cbt_p100-140

OUTDOOR UNIT R410A S - 7

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 8: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

2. CAPACITY TABLES2-2. Correction by total indoor

CITY MULTI TM system has different capacity and input at different total capacity of indoor unit connected. Using following tables, the maximum capacity can be observed so as to ensure the system having enough capacity.

OUTDOOR UNIT R410A S - 8

R410A Data G3

Y

WY

R2

WR2

S

OP

40 60 80 100 120 140 160 180

60 80 100 120 140 160 180 200

Cap

acit

y(kW

)In

pu

t(kW

)

Total capacity of indoor units

9.0

7.0

11.0

13.0

15.0

17.0

0.0

2.0

4.0

Cap

acit

y(kW

)In

pu

t(kW

)

Total capacity of indoor units

11.0

9.0

13.0

15.0

17.0

19.0

0.0

2.0

4.0

CoolingHeating

CoolingHeating

CoolingHeating

P140

PUMY-P100,125YHM

Ref: cbti-pumy140yhm

Ref: cbti-pumy100-125yhmPUMY-P140YHM

P100 P125

Page 9: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

2. CAPACITY TABLES2-2. Correction by total indoor

CITY MULTI TM system has different capacity and input at different total capacity of indoor unit connected. Using following tables, the maximum capacity can be observed so as to ensure the system having enough capacity.

40 60 80 100 120 140 160 180

60 80 100 120 140 160 180 200

Cap

acit

y(kW

)In

pu

t(kW

)

Total capacity of indoor units

9.0

7.0

11.0

13.0

15.0

17.0

0.0

2.0

4.0

Cap

acit

y(kW

)In

pu

t(kW

)

Total capacity of indoor units

11.0

9.0

13.0

15.0

17.0

19.0

0.0

2.0

4.0

CoolingHeating

CoolingHeating

CoolingHeating

P140

PUMY-P100,125VHM

Ref: cbti-pumy140vhm

Ref: cbti-pumy100-125vhmPUMY-P140VHM

P100 P125

OUTDOOR UNIT R410A S - 9

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 10: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

2. CAPACITY TABLES

OUTDOOR UNIT R410A S - 10

R410A Data G3

Y

WY

R2

WR2

S

OP

2-3c. How to obtain the equivalent length of piping

1 PUMY-P100,125,140YHM,VHMEquivalent length = (Actual piping length to the farthest indoor unit) + (0.30 x number of bent on the piping) m

2-3. Correction by refrigerant piping lengthCITY MULTI TM system can extend the piping flexibly within its limitation for the actual situation. Yet, a decrease of cool-ing/heating capacity could happen correspondently. Using following correction factor according to the equivalent length of the piping shown at 2.3a and 2.3b, the capacity can be observed. 2.3c shows how to obtain the equivalent length of piping.

1

0.9

0.8

0.95

0.85

0.75

0.65

0.7

100 20 30 40 50 60 70 80

100 20 30 40 50 60 70 80

100 20 30 40 50 60 70 80

Coo

ling

capa

city

cor

rect

ion

fact

or

Piping equivalent length (m)

1

0.9

0.8

0.95

0.85

0.75

0.65

0.7

Coo

ling

capa

city

cor

rect

ion

fact

or

Piping equivalent length (m)

1

0.9

0.8

0.95

0.85

0.75

0.65

0.7

Coo

ling

capa

city

cor

rect

ion

fact

or

Piping equivalent length (m)Ref.: crpl-p125yhm,vhmc-s

PUMY-P100YHM,VHM

PUMY-P125YHM,VHM

Ref.: crpl-p100yhm,vhmc-s

PUMY-P140YHM,VHM

Ref.: crpl-p140yhm,vhmc-s

Total capacity of indoor unit

Total capacity of indoor unit

Total capacity of indoor unit

2-3a. Cooling capacity correction

PUMY-P100,125,140YHM,VHM

Ref.: crpl-p100_140yhm,vhmh

1

0.9

0.8

0.95

0.85

0.75

0.65

0.7

100 20 30 40 50 60 70 80

Hea

ting

capa

city

cor

rect

ion

fact

or

Piping equivalent length (m)

2-3b. Heating capacity correction

Page 11: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

R410A S - 11

R410A Data G3

Y

WY

R2

WR2

S

OP

2. CAPACITY TABLES2-4. Correction at frosting and defrosting

Due to frosting at the outdoor heat exchanger and the automatical defrosting operation, the heating capacity of the outdoor unit should be considered by multiplying the correction factor which shown in the table below.

OUTDOOR UNIT

Table of correction factor at frosting and defrostingOutdoor inlet air temp. ˚C

Outdoor inlet air temp. ˚FPUMY-P100,125,140YHMPUMY-P100,125,140VHM

6 4 2 1 0 -2 -4 -6 -8 -10 -20431.01.0

390.980.98

360.8550.855

340.850.85

320.8450.845

280.890.89

250.900.90

210.950.95

180.950.95

140.950.95

-4--

2-5. Temp. range of running

30

25

20

15

10

5-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50-4 5 14 23 32 41 50

* 10 to 40˚CDB (50 to 115˚FDB): in case of connecting PKFY-P20/P25 type indoor unit.

59 68 77 86 95 104 113 122

-4 5 14 23 32 41 50 59 68 77 86 95 104 113 122

Indo

or t

empe

ratu

re

Outdoor temperature

30

25

20

15

10

5

86

77

68

59

50

41

86

˚CDB˚FDB

˚CWB˚FWB

77

68

59

50

41-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50

˚CDB˚FDB

˚FWB˚CWB

Indo

or te

mpe

ratu

re

Outdoor temperature

• Cooling

• Heating

Ref.: tr-yhm,vhm-s

Page 12: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

Standard

63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz dB(A)

Night mode

50Hz

60Hz

50/60Hz

* When Night Mode is set, the A/C system's capacity is limited. The system could return to normal operation from Night Mode automatically in the case that the operation condition is severe.

Standard

63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz dB(A)

Night mode

50Hz

60Hz

50/60Hz

* When Night Mode is set, the A/C system's capacity is limited. The system could return to normal operation from Night Mode automatically in the case that the operation condition is severe.

56.2 50.7 48.9 48.8 44.5 40.1 34.9 36.1 50.0

59.9 54.4 51.1 50.4 46.5 42.2 36.1 39.3 52.0

- - - - - - - - -

Standard

63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz dB(A)

Night mode

50Hz

60Hz

50/60Hz

* When Night Mode is set, the A/C system's capacity is limited. The system could return to normal operation from Night Mode automatically in the case that the operation condition is severe.

57.2 51.7 49.9 49.8 45.5 41.1 35.9 37.1 51.0

60.9 55.4 52.1 51.4 47.5 43.2 37.1 40.3 53.0

- - - - - - - - -

55.2 49.7 47.9 47.8 43.5 39.1 33.9 35.1 49.0

58.9 53.4 50.1 49.4 45.5 41.2 35.1 38.3 51.0

- - - - - - - - -

Measurement conditionPUMY-P100,125,140YHMPUMY-P100,125,140VHM

Sound level of PUMY-P100YHM,VHM

Sound level of PUMY-P125YHM,VHM90

85

80

75

70

65

60

55

50

45

40

35

30

25

20

15

10

NC-70

NC-60

NC-50

NC-40

NC-30

NC-20NC-10

Oct

ave

band

sou

nd le

vel (

dB)

Octave band central frequency (Hz)Overall 63 125 250 500 1K 2K 4K 8K

Ref. : P125YHM,VHM-VBN-050093

Approximate minimum audible limit on continuous noise

Sound level of PUMY-P140YHM,VHM90

85

80

75

70

65

60

55

50

45

40

35

30

25

20

15

10

NC-70

NC-60

NC-50

NC-40

NC-30

NC-20NC-10

Oct

ave

band

sou

nd le

vel (

dB)

Octave band central frequency (Hz)Overall 63 125 250 500 1K 2K 4K 8K

Ref. : P140YHM,VHM-VBN-050093

Approximate minimum audible limit on continuous noise

90

85

80

75

70

65

60

55

50

45

40

35

30

25

20

15

10

NC-70

NC-60

NC-50

NC-40

NC-30

NC-20NC-10

Oct

ave

band

sou

nd le

vel (

dB)

Octave band central frequency (Hz)Overall 63 125 250 500 1K 2K 4K 8K

Approximate minimum audible limit on continuous noise

Ref. : P100YHM,VHM-VBN-050093

1.5m

1m

Microphone

Unit

Ground

Standard 50HzStandard 60Hz

Standard 50HzStandard 60Hz

Standard 50HzStandard 60Hz

3. SOUND LEVELS

OUTDOOR UNIT R410A S - 12

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 13: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

PUMY-P100,125,140YHM Drw. : YHM-BK01-B328Unit : mm

Hand

le for

mov

ing

Side

Air

Inta

ke

Fron

t pipi

ng co

ver

Rear

pipi

ng co

ver

Air i

ntak

e

Rear

Air

Inta

ke

Hand

le for

mov

ingHa

ndle

for m

oving

Servi

ce pa

nel

Hand

le for

mov

ing

Air

Dis

char

ge

Rea

r Air

Inta

ke

Sid

e A

ir In

take

145

145

220

3014

581219

71

71

Botto

m p

iping

hole

(Kno

ck-O

ut)

Drain

hole

5-[3

3

600

175

175

28370

70

56

42

56

37

19

53

417

330

Instal

lation

Feet

2-12

o36

Oval

holes

(Fou

ndat

ion B

olt M

10)

2-U S

hape

d notc

hed h

oles

(Fou

ndati

on B

olt M

10)

30

920

322

635 371

950

23

1350

w1 423

w1 507

Hand

le for

mov

ing

1 2(

)

Left··

···

For th

e pow

er su

pply

Cente

r·····F

or the

trans

miss

ion lin

eRi

ght···

·· Fo

r con

centr

ation

contr

ol

Term

inal c

onne

ction

Grou

nd fo

r the

tran

smiss

ion lin

eGr

ound

for c

once

ntrati

on co

ntrol

Grou

nd fo

r the p

ower

supp

ly

Ove

r

Over Over

Ove

r

Less than

Pip

ing

and

wiri

ng c

onne

ctio

nsca

n be

mad

e fro

m 4

dire

ctio

ns:

FRO

NT,

Rig

ht,R

ear a

nd B

elow

.

4 PIP

ING-

WIR

ING

DIRE

CTIO

NS3

FOUN

DATI

ON

BOLT

S2

SERV

ICE

SPAC

E1

FREE

SPA

CE (A

roun

d th

e un

it)P

leas

e se

cure

the

unit

firm

lyw

ith 4

foun

datio

n (M

10) b

olts

.(B

olts

and

was

hers

mus

t be

purc

hase

d lo

cally

.)

<F

ound

atio

n bo

lt he

ight

>

Dim

ensi

ons

of s

pace

nee

ded

for s

ervi

ce a

cces

s ar

esh

own

in th

e be

low

dia

gram

.

The

diag

ram

bel

ow s

how

s a

basi

c ex

ampl

e.E

xpla

ntio

n of

par

ticul

ar d

etai

ls a

regi

ven

in th

e in

stal

latio

n m

anua

ls e

tc.

FREE

Ove

r 10m

m

Ove

r 10m

m

Ove

r 150

mm

Ove

r 150

mm

30

FOUN

DATI

ON

10

500

500100

Ser

vice

spa

ce

Pipi

ng K

nock

-Out

Hol

e De

tails

Exa

mpl

e of

Not

es

• • R

efrig

eran

t GA

S p

ipe

conn

ctio

n[

15.8

8 (5

/8")

Flar

e

• •

• Ref

riger

ant L

IQU

ID p

ipe

conn

ectio

n[

9.5

2 (3

/8")

Flar

ew

1 • •

• In

dica

tion

of S

TOP

VA

LVE

con

nect

ion

loca

tion.

1 2

63 73 23

55 27

92

65

4045

Pow

er s

uppl

y w

iring

hol

e(2

-[27

Kno

ck-O

ut)

Rea

r tru

nkin

g ho

le(K

nock

-Out

)

Rea

r pip

ing

hole

(Kno

ck-O

ut)

[92

92 27 23

63 73

4075

92

5519

Pow

er s

uppl

y w

iring

hol

e(2

-[27

Kno

ck-O

ut)

Rig

ht tr

unki

ng h

ole

(Kno

ck-O

ut)

Rig

ht p

ipin

g ho

le(K

nock

-Out

)

[92

63 73 23

55 27

4045 65

92

Pow

er s

uppl

y w

iring

hol

e(2

-[27

Kno

ck-O

ut)

Fro

nt tr

unki

ng h

ole

(Kno

ck-O

ut)

Fron

t pip

ing

hole

(Kno

ck-O

ut)

[92

4. EXTERNAL DIMENSIONS

OUTDOOR UNIT R410A S - 13

R410A Data G3

Y

WY

R2

WR2

S

OP

Page 14: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

4. EXTERNAL DIMENSIONS

OUTDOOR UNIT R410A S - 14

R410A Data G3

Y

WY

R2

WR2

S

OP

PUMY-P100,125,140VHM Drw. : VHM-BK01-B434Unit : mm

4540

65

92

2755

237363

Rea

r pi

ping

hol

e(K

nock

-Out

)

Rea

r tr

unki

ng h

ole

(Kno

ck-O

ut)

Pow

er s

uppl

y w

iring

hol

e(2

-[27

Kno

ck-O

ut)

1955

92

7540

7363232792

Rig

ht p

ipin

g ho

le(K

nock

-Out

)R

ight

trun

king

hol

e(K

nock

-Out

)

Pow

er s

uppl

y w

iring

hol

e(2

-[27

Kno

ck-O

ut)

[92

92

654540

2755

237363

Fro

nt p

ipin

g ho

le(K

nock

-Out

)

Fro

nt tr

unki

ng h

ole

(Kno

ck-O

ut)

Pow

er s

uppl

y w

iring

hol

e(2

-[27

Kno

ck-O

ut)

[92

145

145

220

3014

581219

71

71

Bot

tom

pip

ing

hole

(Kno

ck-O

ut)

Dra

in h

ole

(5-[

33)

600

175

175

28370

70

56

42

56

37

19

53

417

330

Inst

alla

tion

Fee

t

2-12

o36

Ova

l hol

es(F

ound

atio

n B

olt M

10)

2-U

Sha

ped

notc

hed

hole

s(F

ound

atio

n B

olt M

10)

30

1088

322

635 371

950

23

1350

w1 423

w1 507

Han

dle

for

mov

ing

1 2

Gro

und

for

the

pow

er s

uppl

y("

GR

"mar

king

pos

ition

)

Gro

und

for t

he tr

ansm

issi

on li

neG

roun

d fo

r con

cent

ratio

n co

ntro

l

Ter

min

al b

lock

Left

······

··· F

or th

e po

wer

sup

ply

Cen

ter

···· F

or th

e tr

ansm

issi

on li

neR

ight

·····

·F

or c

once

ntra

tion

cont

rol

(

)

Less than

Ove

r

OverOver

Ove

r

Han

dle

for

mov

ing

Sid

e A

ir In

take

Fro

nt p

ipin

g co

ver

Rea

r pi

ping

cov

er

Air

inta

ke

Rea

r A

ir In

take

Han

dle

for

mov

ing

Han

dle

for

mov

ing

Ser

vice

pan

el

Han

dle

for

mov

ing

The

dia

gram

bel

ow s

how

s a

basi

c ex

ampl

e.E

xpla

ntio

n of

par

ticul

ar d

etai

ls a

regi

ven

in th

e in

stal

latio

n m

anua

ls e

tc.

Dim

ensi

ons

of s

pace

nee

ded

for

serv

ice

acce

ss a

resh

own

in th

e be

low

dia

gram

.

<F

ound

atio

n bo

lt he

ight

>

Ple

ase

secu

re th

e un

it fi

rmly

with

4 fo

unda

tion

(M10

) bo

lts.(

Bol

ts a

nd w

ashe

rs m

ust

be p

urch

ased

loca

lly.)

Air

Dis

char

ge

Rea

r A

ir In

take

Sid

e A

ir In

take

1R

efrig

eran

t GA

S p

ipe

conn

ctio

n(F

LAR

E)[

15.8

8(5/

8F)

2R

efrig

eran

t LIQ

UID

pip

e co

nnec

tion(

FLA

RE

)[ 9

.52(

3/8F

) w

1 ···

·· In

dica

tion

of S

TO

P V

ALV

E c

onne

ctio

n lo

catio

n.

Exa

mpl

e of

Not

es

Pip

ing

Kno

ck-O

ut H

ole

Det

ails

1 FR

EE S

PACE

(Aro

und

the

unit)

2 SE

RVIC

E SP

ACE

3 FO

UNDA

TIO

N BO

LTS

4 PI

PING

-WIR

ING

DIR

ECTI

ONS

Pip

ing

and

wiri

ng c

onne

ctio

nsca

n be

mad

e fr

om 4

dire

ctio

ns:

FR

ON

T,R

ight

,Rea

r an

d B

elow

.

30

FO

UN

DA

TIO

N

150 500

500

10

Ser

vice

spa

ce

Ove

r 10

Ove

r 10

FREE

Ove

r 15

0O

ver

1000

[92

Page 15: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

5. ELECTRICAL WIRING DIAGRAMS

OUTDOOR UNIT R410A S - 15

R410A Data G3

Y

WY

R2

WR2

S

OP

PUMY-P100,125,140YHM Drw. : YHM-RG79-V020

1 2 3 4 5 6 7 8

[Example]When the compressor and SV1 are turned during cooling operation.

Bit

Indication

1

Compressor operated

2

52C

3

21S4

4

SV1

5

(SV2)

6

7

8

Always lit

During normal operation The LED indicates the drive state of the controller in the outdoor unit.

When fault requiring inspection has occurred The LED alternately indicates the inspection code and the location of the unit in which the fault has occurred.

NOTES:1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit. Self-diagnosis function The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch (SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit. LED indication : Set all contacts of SW1 to OFF.

Cautions when Servicing

! WARNING: When the main supply is turned off, the voltage [540 V] in the main capacitor will drop to 20 V in approx. 5 minutes (input voltage: 380 V). When servicing, make sure that LED1, LED2 on the outdoor circuit board goes out, and then wait for at least 5 minute. Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual. Do not replace the outdoor board without checking.

1

MF1

4 5 6 7

CN2(WHT)

CN4(WHT)

CN51(WHT)

1

MF2

4 5 6 7

52C(BLK)3

X50

5

1

21S4(GRN)3 1

SV2(BLU)3 1

SV1(WHT)

SS(WHT)

2 1 2 1 2 1 2 13 1

21S4 SV1

7 6 5 4 3 2 1

54321

2 1LED3

SW6

SW2SW8SW1

SW7SW3SW4w1

SW5SWU2SWU1

TRANS

LED288

LED188

1 2 1 2 1 23 4 CN3D(WHT)

1 2 3

1 2 3

CN3S(RED)1 2 3

CN3N(BLU)1 2 3

31

31

CNAC(RED)

CNS1(RED)

CNS2(YLW)

31

TH7TH6 TH3 TH463HS 63H63L

F1

F5

F2

X50

4

X50

3

X50

2

X50

1

CN102(WHT)

CN41(WHT)

CN40(WHT)

4 3 2 1

4 3 2 14 3 2 1

M-P.B.

P.B.

3 1

CN2(WHT)

CN1(WHT)

TP1

1 2 3 4

M1

M2

S

TB3

TO INDOOR UNITCONNECTING WIRES

DC 30V(Non-polar)

FOR CENTRALIZEDCONTROL

DC 30V(Non-polar)

M1

M2

S

TB7

TB-WTB-VTB-U

TB-L3TB-L2TB-L1

(BLK)(WHT)(RED)

(BLK)

(BLK)

(BLU)

(WHT)

(WHT)

(RED)

(RED)

(BLK)

(BLU)

(WHT)

(RED)L1

NO FUSEBREAKER

POWER SUPPLY3N~

AC400V 50Hz

L2

L3

N

MC

-

+

-

+

3 1 1 3 3 1

1 31 2

ACL4

+

++

CN2(WHT)

CN7(WHT)

CN

4(W

HT)

CN

7(W

HT)

CN

5(R

ED

)

7 6 5 4 3 2 13 2 1

21

21

+ + 31

2

ACL1

ACL2

ACL3

CONV.B.

MULTI. B.

N.F.TB1

CNF1(WHT) TH7/6

(RED)TH3

(WHT)TH4

(WHT)63HS(WHT)

63H(YLW)

63L(RED)

CNDC(PNK)

CNF2(WHT)

TB-P

2

TB-C

1

TB-N

1

L1-IN

L1-A

1

L3-O

U

L3-A

2

L2-O

U

L1-O

U

L2-A

2

L1-A

2

CK-

OU

N-IN

CB1

CN5(RED)

CNAC2(RED)

CB2 CK

RS

LO1

LO2

LO3

NO

LI1

LI2

LI3

NI

GD1 GD2CNAC1(WHT)

CNDC(PNK)

CNL(BLU)

(BRN)

(BRN)

(ORN)

(ORN)

w1 MODEL SELECT 1:ON 0:OFF

MODELS

PUMY-P100YHMPUMY-P125YHMPUMY-P140YHM

1 1 0 0 1 01 2 3 4 5 6

SW4

1 1 0 0 0 11 1 0 0 1 1

SYMBOL NAME SYMBOL NAME SYMBOL NAMETB1 Terminal Block <Power Supply>TB3 Terminal Block <Transmission>TB7 Terminal Block <Contralized Control>MC Motor for CompressorMF1,MF2 Fan Motor21S4 Solenoid Valve<Four way valve>SV1 Solenoid Valve<Bypass valve>TH3 Thermistor<Outdoor Pipe Temperature>TH4 Thermistor<Discharge Temperature>TH6 Thermistor<Low Pressure Saturated Temperature>TH7 Thermistor<Outdoor Temperature>63HS High Pressure Sensor<Discharge Pressure>63H High Pressure Switch63L Low Pressure SwitchCB1,CB2 Main Smoothing CapacitorCK CapacitorRS Rush Current Protect Resistor

P.B Power Circuit BoardConnection Terminal<U/V/W-Phase>

ACL1~ACL4

TB-U/V/W

MULTI.B.

CONV.B.

Multi Controller BoardFuse<6.3A>F1,F2Fuse<3A>F500Switch<Display Selection>SW1Switch<Function Selection>SW2Switch<Test Run>SW3Switch<Model Selection>SW4Switch<Function Selection>SW5Switch<Function Selection>SW6Switch<Function Selection>SW7Switch<Function Selection>SW8Switch<Unit Address Selection, 1st digit>SWU1Switch<Unit Address Selection, 2nd digit>SWU2TransfomerTRANSDigital Indicator<Operation Inspection Display>LED1,2LED<Power Supply to Main Microcomputer>LED3Connector<Multi System>CNS1Connector<Centralized Cotrol>CNS2Connector<To Noise Filter Circuit Board>CNACConnector<To Noise Filter Circuit>CNDCConnector<To Power Circuit Board>CN2Connector<To Power Circuit Board>CN4Connector<Centralized Cotrol Power Supply>CN40Connector<For storing Jumper Connector>CN41Connector<Thermistor>TH3Connector<Thermistor>TH4Connector<Thermistor>TH7/6Connector<High Pressure Sensor>63HSConnector<High Pressure Switch>63HConnector<Low Pressure Switch>63LConnector<Fan Motor>CNF1,CNF2Connector<Four-way Valve>21S4

Connector<Bypass Valve>SV1Connector<For Option>SSConnector<For Option>CN3DConnector<For Option>CN3SConnector<For Option>CN3NConnector<For Option>

Connection Terminal<L1-Power Supply>

CN51RelayX501~505Converter Circuit Board

L1-A1,L1-IN

N.F.Connection Terminal<L1/L2/L3/N-Power Supply>Noise Filter Circuit Board

LI1/LI2/LI3/NI

M-P.B.Connector<To Noise Filter Circuit Board>Transmission Power Board

CN1Connector<To Multi Controller Board>CN2

Connector<To Transmission Power Board>CNAC1Connector<To Multi Controller Board>CNAC2Connector<To Power Circuit Board>CNCTConnector<To Reactor>CNLFuse<6.3A>FUSE

Connection Terminal<L1/L2/L3/N-Power Supply>LO1/LO2/LO3/NO

Connection Terminal<L1-Power Supply>L1-A2,L1-OUConnection Terminal<L2-Power Supply>L2-A2,L2-OUConnection Terminal<L3-Power Supply>L3-A2,L3-OUConnection TerminalN-INConnection TerminalCK-OUConnector<To Power Circuit Board>CN7

Connection Terminal<L1/L2/L3-Power Supply>TB-L1/L2/L3Connection TerminalTB-P2Connection TerminalTB-C1Connection TerminalTB-N1Connection <To Multi Controller Board>CN2Connection <To Multi Controller Board>CN4Connection <To Noise Filter Circuit Board>CN5Connection <To Multi Controller Board>CNDC

Reactor

Page 16: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

5. ELECTRICAL WIRING DIAGRAMS

OUTDOOR UNIT R410A S - 16

R410A Data G3

Y

WY

R2

WR2

S

OP

PUMY-P100,125,140VHM Drw. : VHM-RG79-V221

Page 17: CITY MULTI™ S OUTDOOR UNITS SERIES · 1 1 1 2 3 3 3 1. SPECIFICATIONS OUTDOOR UNIT R410A S - 3 R410A Data G3 Y WY R2 WR2 S OP Details on foundation work, duct work, insulation work,

6. REFRIGERANT CIRCUIT DIAGRAMS AND THERMAL SENSORS

OUTDOOR UNIT R410A S - 17

R410A Data G3

Y

WY

R2

WR2

S

OP

Ref

riger

ant G

as p

ipe

<5/

8>

Ref

riger

ant L

iqui

d pi

pe<

3/8>

Che

ck v

alve

<Lo

w p

ress

ure>

Acc

umul

ator

The

rmis

tor<

Sat

urat

ion

tem

pera

ture

of s

uctio

n pr

essu

re>

(T

H6)

Sol

enoi

dva

lve

(SV

1)

Cap

illar

y tu

be

Pre

ssur

e se

nsor

(63H

S)

Hig

h pr

essu

resw

itch

(63H

)

Che

ck v

alve

<Hig

h pr

essu

re>

Low

pres

sure

switc

h (6

3L)

The

rmis

tor

(TH

7)

Dis

char

geth

erm

isto

r (T

H4)

Rad

iato

r pa

nel

ther

mis

tor

(TH

8)

The

rmis

tor

(TH

3)O

il se

para

tor

Ser

vice

por

t

Ser

vice

port

4-w

ay v

alve

Str

aine

r

Str

aine

r

Stra

iner

Stop

val

ve

Stop

val

ve

Dis

trib

utor

Com

pres

sor

Stra

iner

Ref

riger

ant f

low

in c

oolin

g R

efrig

eran

t flo

w in

hea

ting

Ref

riger

ant p

ipng

spe

cific

atio

ns <

dim

ensi

ons

of fl

ared

con

nect

or>

Cap

acity

Ite

m

Liqu

id p

ipin

gG

as p

ipng

P20

, P25

, P32

, P40

, P50

P63

, P80

, P10

0

P12

5, P

140

P10

0, P

125,

P14

0

Indo

or u

nit

Out

door

uni

t

[ 6

.35

<1/

4">

Fla

re

[ 9

.52

<3/

8">

Fla

re

[ 9

.52

<3/

8">

Fla

re

[ 1

2.7

<1/

2">

Fla

re

[ 1

5.88

<5/

8">

Fla

re [

15.

88 <

5/8"

>F

lare

PUMY-P100,125,140YHMPUMY-P100,125,140VHM

Drw. : RC_VBN-050092