Page 1 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
============================================================================================
Test Report No KA201811861 Date 20180206
Please refer to next page(s)
PVC POWDER
JWC-15
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
StyleItem No
Material Component PVC POWDER
Test Result(s)
Testing Period
Sample Receiving Date
Sample Description
The following sample(s) waswere submitted and identified byon behalf of the applicant as
Sample Submitted By FORMOSA PLASTICS CORPORATION
20180126
20180126 TO 20180206
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 2 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to IEC 62321-5 2013 andperformed by ICP-AES
2 nd
mgkg With reference to IEC 62321-5 2013 andperformed by ICP-AES
2 nd
mgkg With reference to IEC 62321-4 2013 andperformed by ICP-AES
2 nd
mgkg With reference to IEC 62321-7-22017 andperformed by UV-VIS
8 nd
- nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
- nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
WHITE COLORED PVC POWDER
Method
Decabromobiphenyl
Sum of PBDEs
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Unit
Pentabromobiphenyl
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Pentabromodiphenyl ether
Decabromodiphenyl ether
Nonabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Tetrabromobiphenyl
Test Item(s)
With reference to IEC 62321-6 2015 andperformed by GCMS
mgkgWith reference to IEC 62321-6 2015 andperformed by GCMS
Monobromodiphenyl ether
Hexabromobiphenyl
Hexavalent Chromium Cr(VI)
Test Result(s)
Sum of PBBs
Cadmium (Cd)
Lead (Pb)
Dibromodiphenyl ether
Octabromodiphenyl ether
MDL
mgkg
PART NAME No1
Mercury (Hg)
Tribromodiphenyl ether
Tetrabromodiphenyl ether
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 3 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA Method 3052 forBeryllium Content Analysis was performedby ICP-AES
2 nd
mgkg With reference to US EPA Method 3052 forBeryllium Content Analysis was performedby ICP-AES
- nd
SGS In-House method-RSTS-EE-SVHC-007Analyzed by ICP-AES
0005 nd
SGS In-House method-RSTS-EE-SVHC-004Analyzed by ICP-AES
- nd
SGS In-House method-RSTS-EE-SVHC-004Analyzed by ICP-AES
- nd
mgkg SGS In-House method-RSTS-EE-SVHC-007Analyzed by ICP-AES
50 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
05 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
5 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
05 nd
With reference to US EPA 3550C methodAnalysis was performed by GCECD
001 nd
mgkg With reference to ISO 17226-1(2008)Analysis was performed by HPLCDAD
3 ndFormaldehyde (CAS No 50-00-0)
Polychlorinated Terphenyls (PCTs)
Polychlorinated Biphenyls (PCBs)
Cobalt dichloride(CAS No 7646-79-9)
Beryllium (Be)
MDL
Alkanes C10-13 chloro (Short ChainChlorinated Paraffins) (CAS No085535-84-8)
Polychlorinated Naphthalene (PCNs)
Arsenic (As)(2)
Beryllium oxide (BeO)
Diarsenic trioxide(CAS No 1327-53-3)
Diarsenic pentaoxide(CAS No 1303-28-2)
Test Item(s) Unit Method
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 4 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
01 nd
mgkg With reference to IEC 62321 2008 methodAnalysis was performed by GCMS
5 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
100 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
5 nd
μSv hour Geiger counter - Negative
Analysis was performed by FTIR and FLAMETest
- Positive
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg 50 nd
mgkg 50 466000
mgkg 5 nd
mgkg 5 nd
mgkg 5 nd
With reference to US EPA 3550C methodAnalysis was performed by GCMS
With reference to BS EN 145822016Analysis was performed by IC
Benzenamine N-phenyl- reactionproducts with styrene and 244-trimethylpentene (BNST) (CAS No68921-45-9)
Hexabromocyclododecane (HBCDD)and all major diastereoisomersidentified (α- HBCDD β- HBCDD γ-HBCDD) (CAS No 25637-99-4 and3194-55-6 (134237-51-7 134237-50-6 134237-52-8))
2-(35-di-tert-butyl-2-hydroxyphenyl)-2H-benzotriazole (CAS No 3846-71-7)
Test Item(s)
Dimethyl Fumarate (CAS No 624-49-7)
PVC
PFOA (CAS No 335-67-1)
Radioactive Substances
Halogen-Bromine (Br)(CAS No 010097-32-2)
Halogen-Chlorine (Cl)(CAS No 22537-15-1)
Tris(2-chloroethyl) phosphate (TCEP)(CAS No 115-96-8)
TCPP (Tris -(1-chloro-2-propyl)phosphate) (CAS NO13674-84-5)
TDCPP (Tris(13-dichloro-2-propyl)phosphate) (CAS No 13674-87-8)
Unit Method MDL
Perfluorooctane sulfonates (PFOS)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 5 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
- Negative
- Negative
- Negative
- Negative
- Negative
- Negative
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
With reference to EPA 600R-931161993Analysis was performed by StereoMicroscope (SM) Dispersion StainingPolarized Light Microscope (DS-PLM) and X-ray Diffraction Spectrometer (XRD)
With reference to ISO 17353 2004 Analysiswas performed by GCFPD
With reference to IEC 62321-82017Analysis was performed by GCMSDIDP (Di-isodecyl phthalate)
(CAS No 26761-40-0 68515-49-1)DINP (Di-isononyl phthalate)(CAS No 28553-12-0 68515-48-0)DNOP (Di-n-octyl phthalate)(CAS No 117-84-0)DNHP (Di-n-hexyl phthalate) (CASNo 84-75-3)
BBP (Butyl Benzyl phthalate)(CAS No 85-68-7)DBP (Dibutyl phthalate)(CAS No 84-74-2)DEHP (Di- (2-ethylhexyl) phthalate)(CAS No 117-81-7)DIBP (Di-isobutyl phthalate)(CAS No 84-69-5)
Unit Method MDLTest Item(s)
Triphenyl Tin (TphT)
Dibutyl Tin (DBT)
Dioctyl Tin (DOT)
Chrysotile(CAS No 12001-29-5)
Crocidolite(CAS No 12001-28-4)
Tremolite(CAS No 77536-68-6)
Tributyl Tin (TBT)
Asbestos
Actinolite(CAS No 77536-66-4)
Anthophyllite(CAS No 77536-67-5)
Amosite(CAS No 12172-73-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 6 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
MDL
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method
3) 4-CHLORO-O-TOLUIDINE (CASNo 95-69-2)
4) 2-NAPHTHYLAMINE (CAS No91-59-8)
5) O-AMINOAZOTOLUENE (CASNo 97-56-3)
6) 2-AMINO-4-NITROTOLUENE(CAS No 99-55-8)
7) P-CHLOROANILINE (CAS No106-47-8)
AZO1) 4-AMINODIPHENYL (CAS No92-67-1)
2) BENZIDINE (CAS No 92-87-5)
8) 24-DIAMINOANISOLE (CAS No615-05-4)
9) 44-DIAMINODIPHENYLMETHANE(CAS No 101-77-9)
10) 33-DICHLOROBENZIDINE(CAS No 91-94-1)
11) 33-DIMETHOXYBENZIDINE(CAS No 119-90-4)
12) 33-DIMETHYLBENZIDINE(CAS No 119-93-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 7 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method MDL
18) O-TOLUIDINE (CAS No 95-53-4)
19) 24-TOLUYLENEDIAMINE (CASNo 95-80-7)
20) 245-TRIMETHYLANILINE(CAS No 137-17-7)
21) O-ANISIDINE (CAS No 90-04-0)
22) P-AMINOAZOBENZENE (CASNo 60-09-3)
13) 33-DIMETHYL-44-DIAMINODIPHENYLMETHANE(CAS No 838-88-0)
14) P-CRESIDINE (2-METHOXY-5-METHYLANILINE) (CAS No 120-71-8)
15) 44-METHYLENE-BIS- (2-CHLOROANILINE) (CAS No 101-14-4)
16) 44-OXYDIANILINE (CAS No101-80-4)
17) 44-THIODIANILINE (CAS No139-65-1)
23) 24-XYLIDINE (CAS No 95-68-1)
24) 26-XYLIDINE (CAS No 87-62-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 2 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to IEC 62321-5 2013 andperformed by ICP-AES
2 nd
mgkg With reference to IEC 62321-5 2013 andperformed by ICP-AES
2 nd
mgkg With reference to IEC 62321-4 2013 andperformed by ICP-AES
2 nd
mgkg With reference to IEC 62321-7-22017 andperformed by UV-VIS
8 nd
- nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
- nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
5 nd
WHITE COLORED PVC POWDER
Method
Decabromobiphenyl
Sum of PBDEs
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Unit
Pentabromobiphenyl
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Pentabromodiphenyl ether
Decabromodiphenyl ether
Nonabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Tetrabromobiphenyl
Test Item(s)
With reference to IEC 62321-6 2015 andperformed by GCMS
mgkgWith reference to IEC 62321-6 2015 andperformed by GCMS
Monobromodiphenyl ether
Hexabromobiphenyl
Hexavalent Chromium Cr(VI)
Test Result(s)
Sum of PBBs
Cadmium (Cd)
Lead (Pb)
Dibromodiphenyl ether
Octabromodiphenyl ether
MDL
mgkg
PART NAME No1
Mercury (Hg)
Tribromodiphenyl ether
Tetrabromodiphenyl ether
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 3 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA Method 3052 forBeryllium Content Analysis was performedby ICP-AES
2 nd
mgkg With reference to US EPA Method 3052 forBeryllium Content Analysis was performedby ICP-AES
- nd
SGS In-House method-RSTS-EE-SVHC-007Analyzed by ICP-AES
0005 nd
SGS In-House method-RSTS-EE-SVHC-004Analyzed by ICP-AES
- nd
SGS In-House method-RSTS-EE-SVHC-004Analyzed by ICP-AES
- nd
mgkg SGS In-House method-RSTS-EE-SVHC-007Analyzed by ICP-AES
50 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
05 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
5 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
05 nd
With reference to US EPA 3550C methodAnalysis was performed by GCECD
001 nd
mgkg With reference to ISO 17226-1(2008)Analysis was performed by HPLCDAD
3 ndFormaldehyde (CAS No 50-00-0)
Polychlorinated Terphenyls (PCTs)
Polychlorinated Biphenyls (PCBs)
Cobalt dichloride(CAS No 7646-79-9)
Beryllium (Be)
MDL
Alkanes C10-13 chloro (Short ChainChlorinated Paraffins) (CAS No085535-84-8)
Polychlorinated Naphthalene (PCNs)
Arsenic (As)(2)
Beryllium oxide (BeO)
Diarsenic trioxide(CAS No 1327-53-3)
Diarsenic pentaoxide(CAS No 1303-28-2)
Test Item(s) Unit Method
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 4 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
01 nd
mgkg With reference to IEC 62321 2008 methodAnalysis was performed by GCMS
5 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
100 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
5 nd
μSv hour Geiger counter - Negative
Analysis was performed by FTIR and FLAMETest
- Positive
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg 50 nd
mgkg 50 466000
mgkg 5 nd
mgkg 5 nd
mgkg 5 nd
With reference to US EPA 3550C methodAnalysis was performed by GCMS
With reference to BS EN 145822016Analysis was performed by IC
Benzenamine N-phenyl- reactionproducts with styrene and 244-trimethylpentene (BNST) (CAS No68921-45-9)
Hexabromocyclododecane (HBCDD)and all major diastereoisomersidentified (α- HBCDD β- HBCDD γ-HBCDD) (CAS No 25637-99-4 and3194-55-6 (134237-51-7 134237-50-6 134237-52-8))
2-(35-di-tert-butyl-2-hydroxyphenyl)-2H-benzotriazole (CAS No 3846-71-7)
Test Item(s)
Dimethyl Fumarate (CAS No 624-49-7)
PVC
PFOA (CAS No 335-67-1)
Radioactive Substances
Halogen-Bromine (Br)(CAS No 010097-32-2)
Halogen-Chlorine (Cl)(CAS No 22537-15-1)
Tris(2-chloroethyl) phosphate (TCEP)(CAS No 115-96-8)
TCPP (Tris -(1-chloro-2-propyl)phosphate) (CAS NO13674-84-5)
TDCPP (Tris(13-dichloro-2-propyl)phosphate) (CAS No 13674-87-8)
Unit Method MDL
Perfluorooctane sulfonates (PFOS)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 5 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
- Negative
- Negative
- Negative
- Negative
- Negative
- Negative
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
With reference to EPA 600R-931161993Analysis was performed by StereoMicroscope (SM) Dispersion StainingPolarized Light Microscope (DS-PLM) and X-ray Diffraction Spectrometer (XRD)
With reference to ISO 17353 2004 Analysiswas performed by GCFPD
With reference to IEC 62321-82017Analysis was performed by GCMSDIDP (Di-isodecyl phthalate)
(CAS No 26761-40-0 68515-49-1)DINP (Di-isononyl phthalate)(CAS No 28553-12-0 68515-48-0)DNOP (Di-n-octyl phthalate)(CAS No 117-84-0)DNHP (Di-n-hexyl phthalate) (CASNo 84-75-3)
BBP (Butyl Benzyl phthalate)(CAS No 85-68-7)DBP (Dibutyl phthalate)(CAS No 84-74-2)DEHP (Di- (2-ethylhexyl) phthalate)(CAS No 117-81-7)DIBP (Di-isobutyl phthalate)(CAS No 84-69-5)
Unit Method MDLTest Item(s)
Triphenyl Tin (TphT)
Dibutyl Tin (DBT)
Dioctyl Tin (DOT)
Chrysotile(CAS No 12001-29-5)
Crocidolite(CAS No 12001-28-4)
Tremolite(CAS No 77536-68-6)
Tributyl Tin (TBT)
Asbestos
Actinolite(CAS No 77536-66-4)
Anthophyllite(CAS No 77536-67-5)
Amosite(CAS No 12172-73-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 6 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
MDL
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method
3) 4-CHLORO-O-TOLUIDINE (CASNo 95-69-2)
4) 2-NAPHTHYLAMINE (CAS No91-59-8)
5) O-AMINOAZOTOLUENE (CASNo 97-56-3)
6) 2-AMINO-4-NITROTOLUENE(CAS No 99-55-8)
7) P-CHLOROANILINE (CAS No106-47-8)
AZO1) 4-AMINODIPHENYL (CAS No92-67-1)
2) BENZIDINE (CAS No 92-87-5)
8) 24-DIAMINOANISOLE (CAS No615-05-4)
9) 44-DIAMINODIPHENYLMETHANE(CAS No 101-77-9)
10) 33-DICHLOROBENZIDINE(CAS No 91-94-1)
11) 33-DIMETHOXYBENZIDINE(CAS No 119-90-4)
12) 33-DIMETHYLBENZIDINE(CAS No 119-93-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 7 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method MDL
18) O-TOLUIDINE (CAS No 95-53-4)
19) 24-TOLUYLENEDIAMINE (CASNo 95-80-7)
20) 245-TRIMETHYLANILINE(CAS No 137-17-7)
21) O-ANISIDINE (CAS No 90-04-0)
22) P-AMINOAZOBENZENE (CASNo 60-09-3)
13) 33-DIMETHYL-44-DIAMINODIPHENYLMETHANE(CAS No 838-88-0)
14) P-CRESIDINE (2-METHOXY-5-METHYLANILINE) (CAS No 120-71-8)
15) 44-METHYLENE-BIS- (2-CHLOROANILINE) (CAS No 101-14-4)
16) 44-OXYDIANILINE (CAS No101-80-4)
17) 44-THIODIANILINE (CAS No139-65-1)
23) 24-XYLIDINE (CAS No 95-68-1)
24) 26-XYLIDINE (CAS No 87-62-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 3 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA Method 3052 forBeryllium Content Analysis was performedby ICP-AES
2 nd
mgkg With reference to US EPA Method 3052 forBeryllium Content Analysis was performedby ICP-AES
- nd
SGS In-House method-RSTS-EE-SVHC-007Analyzed by ICP-AES
0005 nd
SGS In-House method-RSTS-EE-SVHC-004Analyzed by ICP-AES
- nd
SGS In-House method-RSTS-EE-SVHC-004Analyzed by ICP-AES
- nd
mgkg SGS In-House method-RSTS-EE-SVHC-007Analyzed by ICP-AES
50 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
05 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
5 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
05 nd
With reference to US EPA 3550C methodAnalysis was performed by GCECD
001 nd
mgkg With reference to ISO 17226-1(2008)Analysis was performed by HPLCDAD
3 ndFormaldehyde (CAS No 50-00-0)
Polychlorinated Terphenyls (PCTs)
Polychlorinated Biphenyls (PCBs)
Cobalt dichloride(CAS No 7646-79-9)
Beryllium (Be)
MDL
Alkanes C10-13 chloro (Short ChainChlorinated Paraffins) (CAS No085535-84-8)
Polychlorinated Naphthalene (PCNs)
Arsenic (As)(2)
Beryllium oxide (BeO)
Diarsenic trioxide(CAS No 1327-53-3)
Diarsenic pentaoxide(CAS No 1303-28-2)
Test Item(s) Unit Method
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 4 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
01 nd
mgkg With reference to IEC 62321 2008 methodAnalysis was performed by GCMS
5 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
100 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
5 nd
μSv hour Geiger counter - Negative
Analysis was performed by FTIR and FLAMETest
- Positive
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg 50 nd
mgkg 50 466000
mgkg 5 nd
mgkg 5 nd
mgkg 5 nd
With reference to US EPA 3550C methodAnalysis was performed by GCMS
With reference to BS EN 145822016Analysis was performed by IC
Benzenamine N-phenyl- reactionproducts with styrene and 244-trimethylpentene (BNST) (CAS No68921-45-9)
Hexabromocyclododecane (HBCDD)and all major diastereoisomersidentified (α- HBCDD β- HBCDD γ-HBCDD) (CAS No 25637-99-4 and3194-55-6 (134237-51-7 134237-50-6 134237-52-8))
2-(35-di-tert-butyl-2-hydroxyphenyl)-2H-benzotriazole (CAS No 3846-71-7)
Test Item(s)
Dimethyl Fumarate (CAS No 624-49-7)
PVC
PFOA (CAS No 335-67-1)
Radioactive Substances
Halogen-Bromine (Br)(CAS No 010097-32-2)
Halogen-Chlorine (Cl)(CAS No 22537-15-1)
Tris(2-chloroethyl) phosphate (TCEP)(CAS No 115-96-8)
TCPP (Tris -(1-chloro-2-propyl)phosphate) (CAS NO13674-84-5)
TDCPP (Tris(13-dichloro-2-propyl)phosphate) (CAS No 13674-87-8)
Unit Method MDL
Perfluorooctane sulfonates (PFOS)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 5 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
- Negative
- Negative
- Negative
- Negative
- Negative
- Negative
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
With reference to EPA 600R-931161993Analysis was performed by StereoMicroscope (SM) Dispersion StainingPolarized Light Microscope (DS-PLM) and X-ray Diffraction Spectrometer (XRD)
With reference to ISO 17353 2004 Analysiswas performed by GCFPD
With reference to IEC 62321-82017Analysis was performed by GCMSDIDP (Di-isodecyl phthalate)
(CAS No 26761-40-0 68515-49-1)DINP (Di-isononyl phthalate)(CAS No 28553-12-0 68515-48-0)DNOP (Di-n-octyl phthalate)(CAS No 117-84-0)DNHP (Di-n-hexyl phthalate) (CASNo 84-75-3)
BBP (Butyl Benzyl phthalate)(CAS No 85-68-7)DBP (Dibutyl phthalate)(CAS No 84-74-2)DEHP (Di- (2-ethylhexyl) phthalate)(CAS No 117-81-7)DIBP (Di-isobutyl phthalate)(CAS No 84-69-5)
Unit Method MDLTest Item(s)
Triphenyl Tin (TphT)
Dibutyl Tin (DBT)
Dioctyl Tin (DOT)
Chrysotile(CAS No 12001-29-5)
Crocidolite(CAS No 12001-28-4)
Tremolite(CAS No 77536-68-6)
Tributyl Tin (TBT)
Asbestos
Actinolite(CAS No 77536-66-4)
Anthophyllite(CAS No 77536-67-5)
Amosite(CAS No 12172-73-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 6 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
MDL
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method
3) 4-CHLORO-O-TOLUIDINE (CASNo 95-69-2)
4) 2-NAPHTHYLAMINE (CAS No91-59-8)
5) O-AMINOAZOTOLUENE (CASNo 97-56-3)
6) 2-AMINO-4-NITROTOLUENE(CAS No 99-55-8)
7) P-CHLOROANILINE (CAS No106-47-8)
AZO1) 4-AMINODIPHENYL (CAS No92-67-1)
2) BENZIDINE (CAS No 92-87-5)
8) 24-DIAMINOANISOLE (CAS No615-05-4)
9) 44-DIAMINODIPHENYLMETHANE(CAS No 101-77-9)
10) 33-DICHLOROBENZIDINE(CAS No 91-94-1)
11) 33-DIMETHOXYBENZIDINE(CAS No 119-90-4)
12) 33-DIMETHYLBENZIDINE(CAS No 119-93-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 7 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method MDL
18) O-TOLUIDINE (CAS No 95-53-4)
19) 24-TOLUYLENEDIAMINE (CASNo 95-80-7)
20) 245-TRIMETHYLANILINE(CAS No 137-17-7)
21) O-ANISIDINE (CAS No 90-04-0)
22) P-AMINOAZOBENZENE (CASNo 60-09-3)
13) 33-DIMETHYL-44-DIAMINODIPHENYLMETHANE(CAS No 838-88-0)
14) P-CRESIDINE (2-METHOXY-5-METHYLANILINE) (CAS No 120-71-8)
15) 44-METHYLENE-BIS- (2-CHLOROANILINE) (CAS No 101-14-4)
16) 44-OXYDIANILINE (CAS No101-80-4)
17) 44-THIODIANILINE (CAS No139-65-1)
23) 24-XYLIDINE (CAS No 95-68-1)
24) 26-XYLIDINE (CAS No 87-62-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 4 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
01 nd
mgkg With reference to IEC 62321 2008 methodAnalysis was performed by GCMS
5 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
100 nd
mgkg With reference to US EPA 3550C methodAnalysis was performed by GCMS
5 nd
μSv hour Geiger counter - Negative
Analysis was performed by FTIR and FLAMETest
- Positive
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg With reference to US EPA 3550C 2007Analysis was performed by LCMS
10 nd
mgkg 50 nd
mgkg 50 466000
mgkg 5 nd
mgkg 5 nd
mgkg 5 nd
With reference to US EPA 3550C methodAnalysis was performed by GCMS
With reference to BS EN 145822016Analysis was performed by IC
Benzenamine N-phenyl- reactionproducts with styrene and 244-trimethylpentene (BNST) (CAS No68921-45-9)
Hexabromocyclododecane (HBCDD)and all major diastereoisomersidentified (α- HBCDD β- HBCDD γ-HBCDD) (CAS No 25637-99-4 and3194-55-6 (134237-51-7 134237-50-6 134237-52-8))
2-(35-di-tert-butyl-2-hydroxyphenyl)-2H-benzotriazole (CAS No 3846-71-7)
Test Item(s)
Dimethyl Fumarate (CAS No 624-49-7)
PVC
PFOA (CAS No 335-67-1)
Radioactive Substances
Halogen-Bromine (Br)(CAS No 010097-32-2)
Halogen-Chlorine (Cl)(CAS No 22537-15-1)
Tris(2-chloroethyl) phosphate (TCEP)(CAS No 115-96-8)
TCPP (Tris -(1-chloro-2-propyl)phosphate) (CAS NO13674-84-5)
TDCPP (Tris(13-dichloro-2-propyl)phosphate) (CAS No 13674-87-8)
Unit Method MDL
Perfluorooctane sulfonates (PFOS)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 5 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
- Negative
- Negative
- Negative
- Negative
- Negative
- Negative
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
With reference to EPA 600R-931161993Analysis was performed by StereoMicroscope (SM) Dispersion StainingPolarized Light Microscope (DS-PLM) and X-ray Diffraction Spectrometer (XRD)
With reference to ISO 17353 2004 Analysiswas performed by GCFPD
With reference to IEC 62321-82017Analysis was performed by GCMSDIDP (Di-isodecyl phthalate)
(CAS No 26761-40-0 68515-49-1)DINP (Di-isononyl phthalate)(CAS No 28553-12-0 68515-48-0)DNOP (Di-n-octyl phthalate)(CAS No 117-84-0)DNHP (Di-n-hexyl phthalate) (CASNo 84-75-3)
BBP (Butyl Benzyl phthalate)(CAS No 85-68-7)DBP (Dibutyl phthalate)(CAS No 84-74-2)DEHP (Di- (2-ethylhexyl) phthalate)(CAS No 117-81-7)DIBP (Di-isobutyl phthalate)(CAS No 84-69-5)
Unit Method MDLTest Item(s)
Triphenyl Tin (TphT)
Dibutyl Tin (DBT)
Dioctyl Tin (DOT)
Chrysotile(CAS No 12001-29-5)
Crocidolite(CAS No 12001-28-4)
Tremolite(CAS No 77536-68-6)
Tributyl Tin (TBT)
Asbestos
Actinolite(CAS No 77536-66-4)
Anthophyllite(CAS No 77536-67-5)
Amosite(CAS No 12172-73-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 6 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
MDL
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method
3) 4-CHLORO-O-TOLUIDINE (CASNo 95-69-2)
4) 2-NAPHTHYLAMINE (CAS No91-59-8)
5) O-AMINOAZOTOLUENE (CASNo 97-56-3)
6) 2-AMINO-4-NITROTOLUENE(CAS No 99-55-8)
7) P-CHLOROANILINE (CAS No106-47-8)
AZO1) 4-AMINODIPHENYL (CAS No92-67-1)
2) BENZIDINE (CAS No 92-87-5)
8) 24-DIAMINOANISOLE (CAS No615-05-4)
9) 44-DIAMINODIPHENYLMETHANE(CAS No 101-77-9)
10) 33-DICHLOROBENZIDINE(CAS No 91-94-1)
11) 33-DIMETHOXYBENZIDINE(CAS No 119-90-4)
12) 33-DIMETHYLBENZIDINE(CAS No 119-93-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 7 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method MDL
18) O-TOLUIDINE (CAS No 95-53-4)
19) 24-TOLUYLENEDIAMINE (CASNo 95-80-7)
20) 245-TRIMETHYLANILINE(CAS No 137-17-7)
21) O-ANISIDINE (CAS No 90-04-0)
22) P-AMINOAZOBENZENE (CASNo 60-09-3)
13) 33-DIMETHYL-44-DIAMINODIPHENYLMETHANE(CAS No 838-88-0)
14) P-CRESIDINE (2-METHOXY-5-METHYLANILINE) (CAS No 120-71-8)
15) 44-METHYLENE-BIS- (2-CHLOROANILINE) (CAS No 101-14-4)
16) 44-OXYDIANILINE (CAS No101-80-4)
17) 44-THIODIANILINE (CAS No139-65-1)
23) 24-XYLIDINE (CAS No 95-68-1)
24) 26-XYLIDINE (CAS No 87-62-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 5 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
- Negative
- Negative
- Negative
- Negative
- Negative
- Negative
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 003 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
mgkg 50 nd
With reference to EPA 600R-931161993Analysis was performed by StereoMicroscope (SM) Dispersion StainingPolarized Light Microscope (DS-PLM) and X-ray Diffraction Spectrometer (XRD)
With reference to ISO 17353 2004 Analysiswas performed by GCFPD
With reference to IEC 62321-82017Analysis was performed by GCMSDIDP (Di-isodecyl phthalate)
(CAS No 26761-40-0 68515-49-1)DINP (Di-isononyl phthalate)(CAS No 28553-12-0 68515-48-0)DNOP (Di-n-octyl phthalate)(CAS No 117-84-0)DNHP (Di-n-hexyl phthalate) (CASNo 84-75-3)
BBP (Butyl Benzyl phthalate)(CAS No 85-68-7)DBP (Dibutyl phthalate)(CAS No 84-74-2)DEHP (Di- (2-ethylhexyl) phthalate)(CAS No 117-81-7)DIBP (Di-isobutyl phthalate)(CAS No 84-69-5)
Unit Method MDLTest Item(s)
Triphenyl Tin (TphT)
Dibutyl Tin (DBT)
Dioctyl Tin (DOT)
Chrysotile(CAS No 12001-29-5)
Crocidolite(CAS No 12001-28-4)
Tremolite(CAS No 77536-68-6)
Tributyl Tin (TBT)
Asbestos
Actinolite(CAS No 77536-66-4)
Anthophyllite(CAS No 77536-67-5)
Amosite(CAS No 12172-73-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 6 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
MDL
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method
3) 4-CHLORO-O-TOLUIDINE (CASNo 95-69-2)
4) 2-NAPHTHYLAMINE (CAS No91-59-8)
5) O-AMINOAZOTOLUENE (CASNo 97-56-3)
6) 2-AMINO-4-NITROTOLUENE(CAS No 99-55-8)
7) P-CHLOROANILINE (CAS No106-47-8)
AZO1) 4-AMINODIPHENYL (CAS No92-67-1)
2) BENZIDINE (CAS No 92-87-5)
8) 24-DIAMINOANISOLE (CAS No615-05-4)
9) 44-DIAMINODIPHENYLMETHANE(CAS No 101-77-9)
10) 33-DICHLOROBENZIDINE(CAS No 91-94-1)
11) 33-DIMETHOXYBENZIDINE(CAS No 119-90-4)
12) 33-DIMETHYLBENZIDINE(CAS No 119-93-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 7 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method MDL
18) O-TOLUIDINE (CAS No 95-53-4)
19) 24-TOLUYLENEDIAMINE (CASNo 95-80-7)
20) 245-TRIMETHYLANILINE(CAS No 137-17-7)
21) O-ANISIDINE (CAS No 90-04-0)
22) P-AMINOAZOBENZENE (CASNo 60-09-3)
13) 33-DIMETHYL-44-DIAMINODIPHENYLMETHANE(CAS No 838-88-0)
14) P-CRESIDINE (2-METHOXY-5-METHYLANILINE) (CAS No 120-71-8)
15) 44-METHYLENE-BIS- (2-CHLOROANILINE) (CAS No 101-14-4)
16) 44-OXYDIANILINE (CAS No101-80-4)
17) 44-THIODIANILINE (CAS No139-65-1)
23) 24-XYLIDINE (CAS No 95-68-1)
24) 26-XYLIDINE (CAS No 87-62-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 6 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
MDL
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method
3) 4-CHLORO-O-TOLUIDINE (CASNo 95-69-2)
4) 2-NAPHTHYLAMINE (CAS No91-59-8)
5) O-AMINOAZOTOLUENE (CASNo 97-56-3)
6) 2-AMINO-4-NITROTOLUENE(CAS No 99-55-8)
7) P-CHLOROANILINE (CAS No106-47-8)
AZO1) 4-AMINODIPHENYL (CAS No92-67-1)
2) BENZIDINE (CAS No 92-87-5)
8) 24-DIAMINOANISOLE (CAS No615-05-4)
9) 44-DIAMINODIPHENYLMETHANE(CAS No 101-77-9)
10) 33-DICHLOROBENZIDINE(CAS No 91-94-1)
11) 33-DIMETHOXYBENZIDINE(CAS No 119-90-4)
12) 33-DIMETHYLBENZIDINE(CAS No 119-93-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 7 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method MDL
18) O-TOLUIDINE (CAS No 95-53-4)
19) 24-TOLUYLENEDIAMINE (CASNo 95-80-7)
20) 245-TRIMETHYLANILINE(CAS No 137-17-7)
21) O-ANISIDINE (CAS No 90-04-0)
22) P-AMINOAZOBENZENE (CASNo 60-09-3)
13) 33-DIMETHYL-44-DIAMINODIPHENYLMETHANE(CAS No 838-88-0)
14) P-CRESIDINE (2-METHOXY-5-METHYLANILINE) (CAS No 120-71-8)
15) 44-METHYLENE-BIS- (2-CHLOROANILINE) (CAS No 101-14-4)
16) 44-OXYDIANILINE (CAS No101-80-4)
17) 44-THIODIANILINE (CAS No139-65-1)
23) 24-XYLIDINE (CAS No 95-68-1)
24) 26-XYLIDINE (CAS No 87-62-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 7 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
mgkg 3 nd
With reference to LFGB BVL B 8202-2Analysis was performed by GCMS
Test Item(s) Unit Method MDL
18) O-TOLUIDINE (CAS No 95-53-4)
19) 24-TOLUYLENEDIAMINE (CASNo 95-80-7)
20) 245-TRIMETHYLANILINE(CAS No 137-17-7)
21) O-ANISIDINE (CAS No 90-04-0)
22) P-AMINOAZOBENZENE (CASNo 60-09-3)
13) 33-DIMETHYL-44-DIAMINODIPHENYLMETHANE(CAS No 838-88-0)
14) P-CRESIDINE (2-METHOXY-5-METHYLANILINE) (CAS No 120-71-8)
15) 44-METHYLENE-BIS- (2-CHLOROANILINE) (CAS No 101-14-4)
16) 44-OXYDIANILINE (CAS No101-80-4)
17) 44-THIODIANILINE (CAS No139-65-1)
23) 24-XYLIDINE (CAS No 95-68-1)
24) 26-XYLIDINE (CAS No 87-62-7)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 8 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg 02 0504
mgkg 02 nd
mgkg 02 0357
mgkg 02 111
mgkg 02 nd
mgkg 02 nd
mgkg 02 nd
mgkg - - 1971
MDL
With reference to AfPS GS 201401 PAKmethod Analysis was performed by GCMS
Test Item(s) Unit Method
Acenaphthene (CAS No 83-32-9)
Acenaphthylene (CAS No 208-96-8)
Anthracene (CAS No 120-12-7)
Benzo[a]anthracene (CAS No 56-55-3)Benzo[a]pyrene (CAS No 50-32-8)
Polynuclear Aromatic
Hydrocarbons (PAHs)
Pyrene (CAS No 129-00-0)
Benzo[j]fluoranthene (CAS No 205-82-3)Benzo[e]pyrene (CAS No 192-97-2)
Sum of 18 PAHs
Fluoranthene (CAS No 206-44-0)
Fluorene (CAS No 86-73-7)
Indeno[123-cd] pyrene (CAS No193-39-5)Naphthalene (CAS No 91-20-3)
Phenanthrene (CAS No 85-01-8)
Benzo[b]fluoranthene (CAS No 205-99-2)Benzo[ghi]perylene (CAS No 191-24-2)Benzo[k]fluoranthene (CAS No 207-08-9)Chrysene (CAS No 218-01-9)
Dibenzo[ah]anthracene (CAS No53-70-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 9 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HFC-143 (CH3F3)
HFC-143a (CH3F3)
HFC-152a (C2H4F2)(CAS No 75-37-6)
HFC-227ea (C3HF7)(CAS No 431-89-0)
HFC-236ea (C3H2F6)(CAS No 431-63-0)
HFC-41 (CH3F)(CAS No 593-53-3)
HFC-43-10mee (C5H2F10)
HFC-125 (C2HF5)
HFC-134 (C2H2F4)
HFC-134a (CH2FCF3)(CAS No811-97-2)
HFCs (Hydrofluorocarbon)
HFC-23 (CHF3)(CAS No 75-46-7)
HFC-32 (CH2F2)(CAS No 75-10-5)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 10 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Perfluor-1-butene (CAS No 357-26-6)
perfluorisobutene (CAS No 382-21-8)
14-dihydrooctafluorobutane (CASNo 377-36-6)
Test Item(s)
F14 (CAS No 75-73-0)
Fluorocarbon 116 (CAS No 76-16-4)
Freon 218 (CAS No 76-19-7)
Decafluorobutane (CAS No 355-25-9)
Freon C318 (CAS No 115-25-3)
HFC-236fa (C3H2F6)
HFC-245ca (C3H3F5)
HFC-245fa (C3H3F5)
HFC-365mfc (C4H5F5)
PFCs (Perfluorocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 11 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
Chlorofluorocarbon-12 (CAS No 75-71-8)
Chlorofluorocarbon-113 (CAS No76-13-1)
Chlorofluorocarbon-114 (CAS No76-14-2)
Chlorofluorocarbon-115 (CAS No76-15-3)
2-perfluoromethylpentane (CAS No355-04-4)
Perfluorohexane (CAS No 355-42-0)
CFCs (Chlorofluorocarbons)
Group I
Chlorofluorocarbon-11 (CAS No 75-69-4)
Nonafluor-2- (trifluoromethyl) butane(CAS No 594-91-2)
Perfluoro-n-pentane (CAS No 678-26-2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 12 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
Chlorofluorocarbon-13 (CAS No 75-72-9)
Chlorofluorocarbon-111 (CAS No354-56-3)
Chlorofluorocarbon-112 (CAS No76-12-0)
Chlorofluorocarbon-211 (CAS No422-78-6)
Chlorofluorocarbon-212 (CAS No3182-26-1)
Test Item(s)
Chlorofluorocarbon-213 (CAS No2354-06-5)
Chlorofluorocarbon-214 (CAS No29255-31-0)
Chlorofluorocarbon-215 (CAS No4259-43-2)
Chlorofluorocarbon-216 (CAS No661-97-2)
Chlorofluorocarbon-217 (CAS No422-86-6)
Group III
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 13 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-133a (CAS No 75-88-7)
HCFC-141b (CAS No 1717-00-6)
HCFC-142b (CAS No 75-68-3)
HCFC-122 (CAS No 354-21-2)
HCFC-123 (CAS No 306-83-2)
HCFC-124 (CAS No 2837-89-0)
HCFC-131 (CAS No 359-28-4)
HCFC-132b (CAS No 1649-08-7)
HCFCs
(Hydrochlorofluorocarbons)HCFC-21 (CAS No 75-43-4)
HCFC-22 (CAS No 75-45-6)
HCFC-31 (CAS No 593-70-4)
HCFC-121 (CAS No 354-14-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 14 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HCFC-231 (CAS No 421-94-3)
HCFC-232 (CAS No 460-89-9)
HCFC-233 (CAS No 7125-84-0)
HCFC-234 (CAS No 425-94-5)
HCFC-235 (CAS No 460-92-4)
HCFC-223 (CAS No 422-52-6)
HCFC-224 (CAS No 422-54-8)
HCFC-225ca (CAS No 422-56-0)
HCFC-225cb (CAS No 507-55-1)
HCFC-226 (CAS No 431-87-8)
Test Item(s)
HCFC-221 (CAS No 422-26-4)
HCFC-222 (CAS No 422-49-1)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 15 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HCFC-252 (CAS No 819-00-1)
HCFC-253 (CAS No 460-35-5)
HCFC-261 (CAS No 420-97-3)
HCFC-262 (CAS No 421-02-03)
HCFC-271 (CAS No 430-55-7)
HCFC-241(CAS No 666-27-3)
HCFC-242 (CAS No 460-63-9)
HCFC-243 (CAS No 460-69-5)
HCFC-244
HCFC-251 (CAS No 421-41-0)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 16 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-123B2 (C2HF3Br2)
HBFC-124B1 (C2HF4Br)
HBFC-131B3 (C2H2FBr3)
Test Item(s)
HBFC-21B2 (CHFBr2) (CAS No1868-53-7)
HBFC-22B1 (CHF2Br) (CAS No1511-62-2)
HBFC-31B1 (CH2FBr) (CAS No373-52-4)
HBFC-121B4 (C2HFBr4)
HBFC-122B3 (C2HF2Br3)
Halons
Halon-1211(CAS No 353-59-3)
Halon-1301(CAS No 75-63-8)
Halon-2402(CAS No 124-73-2)
HBFCs
(Hydrobromofluorocarbons)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 17 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
HBFC-223B4 (C3HF3Br4)
HBFC-224B3 (C3HF4Br3)
HBFC-225B2 (C3HF5Br2)
HBFC-226B1 (C3HF6Br)
HBFC-231B5 (C3H2FBr5)
HBFC-141B2 (C2H3FBr2)
HBFC-142B1 (C2H3F2Br)
HBFC-151B1 (C2H4FBr)
HBFC-221B6 (C3HFBr6)
HBFC-222B5 (C3HF2Br5)
HBFC-132B2 (C2H2F2Br2)
HBFC-133B1 (C2H2F3Br)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 18 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDL
HBFC-253B1 (C3H4F3Br)
HBFC-261B2 (C3H5FBr2)
Test Item(s)
HBFC-232B4 (C3H2F2Br4)
HBFC-233B3 (C3H2F3Br3)
HBFC-234B2 (C3H2F4Br2)
HBFC-235B1 (C3H2F5Br)
HBFC-241B4 (C3H3FBr4)
HBFC-242B3 (C3H3F2Br3)
HBFC-243B2 (C3H3F3Br2)
HBFC-244B1 (C3H3F4Br)
HBFC-251B3 (C3H4FBr3)
HBFC-252B2 (C3H4F2Br2)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 19 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Test Item(s) Unit Method MDL
11-Dichloroethene (CAS No 75-35-4)
11-Dichloropropene (CAS No 563-58-6)
123-Trichloropropane (CAS No 96-18-4)
12-Dichloroethane (CAS No 107-06-2)
12-Dichloropropane (CAS No 78-87-5)
1112-Tetrachloroethane (CAS No630-20-6)
111-Trichloroethane (CAS No 71-55-6)
1122-Tetrachloroethane (CAS No79-34-5)
112-Trichloroethane (CAS No 79-00-5)
11-Dichloroethane (CAS No 75-34-3)
HBFC-262B1 (C3H5F2Br)
HBFC-271B1 (C3H6FBr)
CHCs (Chlorinate hydrocarbon)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 20 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Unit Method MDLTest Item(s)
Tetrachloroethene (CAS No 127-18-4)
trans-12-Dichloroethene (CAS No156-60-5)
Chloromethane (CAS No 74-87-3)
cis-12-Dichloroethene (CAS No156-59-2)
cis-13-Dichloropropene (CAS No10061-01-5)
Hexachlorobutadiene (CAS No 87-68-3)
Methylene Chloride (CAS No 75-09-2)
13-Dichloropropane (CAS No 142-28-9)
22-Dichloropropane (CAS No 594-20-7)
Carbon tetrachloride (CAS No 56-23-5)
Chloroethane (CAS No 75-00-3)
Chloroform (CAS No 67-66-3)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 21 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Result
No1
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
mgkg With reference to US EPA 5021A methodAnalysis was performed by GCMS
1 nd
Result
No1
mgkg Analysis was performed by IC 01 nd
1
2
3
4
5
6
7
8
9
10
The substance was calculated by the test results of Dioctyl Tin MonooctylTin Beryllium orBoron or Arsenic The MDL is evaluated for Dioctyl Tin MonooctylTin Beryllium orBoron for Arsenic
F Parameter Conversion TablePlease refer to httptwapsgscomsgsrstschndownload-REACH_twasp
Since beryllium copper is a metal alloy of copper and beryllium and the test result is nd for berylliumwe can have conclusion that the beryllium copper is nd
= Qualitative analysis (No Unit)
Negative = Undetectable Positive = Detectable
Testing range of asbestos qualitative analysis is from less than 01 to 100 The judgment criterion asbestosfibers being found is shown as Positive asbestos fibers not being found is shown as Negative
Test Item(s) Unit Method LOQLOD
Test Item(s) Unit Method MDL
mgkg = ppm01wt = 1000ppm
nd = Not Detected
MDL = Method Detection Limit
- = Not Regulated
Perchlorate
Sulfur Hexafluoride (SF6) (CAS No2551-62-4)
trans-13-Dichloropropene (CAS No10061-02-6)
Trichloroethylene (CAS No 79-01-6)
Bromomethane (CAS No 74-83-9)
Note
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 22 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
11
12
13
14
15
If the testing item belongs to quantitative analysis then this column describes Limit of Quantification(LOQ)If the testing item belongs to qualitative analysis then this column describes Limit of Detection(LOD)
PFOS Reference Information POPs - (EU) 7572010
Outlawing PFOS as substances or preparations in concentrations above 0001 (10ppm) in semi-finished products orarticles or parts at a level above 01(1000ppm) in textiles or other coated materials above 1microgmsup2PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid Perfluoroctanesulfonamide N-Methylperfluoroctane sulfonamide N-Ethylperfluoroctane sulfonamide N-Methylperfluoroctanesulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol
The content of this report is invalid if it is not presented as the entire report
NegativePositive The test result of Geiger counter is from comparison between test outcome andenvironment background In general there is little radiation dose existing in environment
(Radiation dose from environment background usually less than or equal to 02microSvhr)The test result less than environment background was shown as Negative the result greater thanenvironment background was shown as Positive
This is the additional test report of KA20176109 which was issued on 20170622 Please refer to KA20176109 fororiginal information
(2) The extracted soluble Arsenic are detected by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 23 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
AfPS (German commission for Product Safety) GS PAHs requirements
Parameter Category 1
Toy under
200948EC
Other
products
under ProdSG
Toy under
200948EC
Other
products
under ProdSG
Naphthalene lt 1
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo[a]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Chrysene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[b]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[j]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[k]fluoranthene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[a]pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[e]pyrene lt 02 lt 02 lt 05 lt 05 lt 1Indeno[123-cd] pyrene lt 02 lt 02 lt 05 lt 05 lt 1
Dibenzo[ah]anthracene lt 02 lt 02 lt 05 lt 05 lt 1
Benzo[ghi]perylene lt 02 lt 02 lt 05 lt 05 lt 1
Sum of 18 PAH lt 1 lt 5 lt 10 lt 20 lt 50
lt 1 Sum
lt 2 lt 10
lt 50 Sumlt 20 Sumlt 10 Sumlt 5 Sum
Category 2 Category 3
Materials not falling under
category 1 with foreseeable
contact to skin for longer
than 30 seconds (long-term
skin or frequent contact)
Materials not falling under
category 1 or 2 with
foreseeable contact to skin
for less than 30 seconds
(short-term skin contact)
(Material indented
to be put in the
mouth or toys with
intended skin
contact (longer than
30 s)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 24 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
FLOW
Analytical flow chart of Heavy Metal
These samples were dissolved totally by pre-conditioning method according to below flow chart(Cr6+
test method excluded)
Technician Jony Liu Supervisor Ray Chang
CuttingPreparation
Sample Measurement
Microwave digestion Hotplate digestion
PbCdHg
Filtration
Solution Residue
1) Alkali fusion2) HCl to dissolve
Filtration
ICP-AES
Cr6+
Non-metal Metal
Dissolving by
ultrasonication
Digesting at150~160
ABS PC PVC Others
Boiling waterextraction
Cool filter
digestate through
filter
Add diphenyl-
carbazide for colordevelopment
Measure theabsorbance at 540
nm by UV-VIS
Separating to get
aqueous phase
Digesting at 60
by ultrasonication
pH adjustment
Add diphenyl-carbazide for
color development
Measure the absorbance at540 nm by UV-VIS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 25 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PBBPBDE analytical FLOW CHART
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Sample
Issue Report
Sample pretreatment
Sample extractionSoxhlet method
ConcentrateDiluteExtracted solution
Analysis by GCMS
Filter
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 26 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Flow Chart of digestion for the elements analysis performed by ICP-AES
1) These samples were dissolved totally by pre-conditioning method according to below
flow chart
2) Name of the person who made measurement Jony Liu
3) Name of the person in charge of measurement Ray Chang
ICP-AES
Acid digestion by suitable acid depended on different sample material (as below
table)
Filtration
SolutionResidue
1) Alkali Fusion
2) HCl to dissolve
Sample Measurement
CuttingPreparation
Steel copper aluminum solder Aqua regia HNO3 HCl HF H2O2
Glass HNO3HF
Gold platinum palladium ceramic Aqua regia
Silver HNO3
Plastic H2SO4 H2O2 HNO3 HCl
Others Any acid to total digestion
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 27 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Cobalt dichloride
1) Name of the person who made measurement Jony Liu
2) Name of the person in charge of measurement Ray Chang
Sampling
Sample pretreated by acid digestion andsolvent extraction
Data
Analysis was performed by ICP-AES
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 28 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCECD
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCBs CP MCCP
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 29 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Chlorinated Flame retardant analytical flow chart
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute the extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Reference method US EPA 3550C
Test Items PCNs PCTs Mirex
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 30 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Dimethyl Fumarate content
Sample pretreatment
Sample extraction by organic solvent
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 31 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
HBCDD analytical flow chart
1) Name of the person who made measurement Dorothy Chen2) Name of the person in charge of measurement Ray Chang
Data
Sample extraction Ultrasonic method
Analysis was performed by GCMS
Filter
Sample pretreatment
ConcentrateDilute Extracted solution
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 32 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of benzotriazole content
Sample pretreatment
Sample extraction by soxhlet method
(Reference method US EPA 3540)
ConcentrateDilute Extracted solution
Analysis was performed by GCMS
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 33 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of
PVC in polymer material
1) Name of the person who made measurement Hannah Tai2) Name of the person in charge of measurement Roger Lin
Sample pre-treatment
Sample analyzed by FTIR
Check wave-number of C-Cl bond
Flame test
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 34 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of PFOAPFOS content
1) Name of the person who made measurement Ginny Huang
2) Name of the person in charge of measurement Ray Chang
Sample pretreatment
Sample extraction by ultrasonic method
(Reference method US EPA 3550)
ConcentrateDilute Extracted solution
Analysis was performed by LCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 35 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of halogen content
1) Name of the person who made measurement Jean Hung
2) Name of the person in charge of measurement Ray Chang
Sample picture and report number
Sample pretreatmentseparation
Weighting and putting sample in cell
Oxygen Bomb Combustion Absorption
Analysis was performed by IC
Dilution to fixed volume
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 36 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analysis flow chart for determination of Asbestos
Name of the person who made measurement Victor Kao
Name of the person in charge of measurement Wendy Wei
【Reference method EPA 600R-93116】
Sampling
Transportation and Storage
Preparation of primary analytical sample
Containing AsbestosPositive
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Asbestos fiber is present Asbestos fiber is absent
Not containing AsbestosNegative
Examination by stereomicroscope (SM)
Asbestos identification by dispersion stainingpolarized light microscope (DS-PLM)
Continue when problems are encountered withDS-PLM andor for quality assurance purposes
Interference matrix removal
Asbestos identification by X-raydiffraction spectrometer (XRD)
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 37 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of Organic-Tin content
Sample pretreatment
Sample extraction by organic solvent
Derived by Sodium tetraethylborate
ConcentrateDilute Extracted solution
Data
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
Analysis was performed by GCFPD
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 38 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
Analytical flow chart of phthalate content
Name of the person who made measurement Dorothy Chen
Name of the person in charge of measurement Ray Chang
【Test method IEC 62321-8】
Sample pretreatmentseparation
Sample dissolvedextracted by THF
Dilute Extracted solution
Analysis was performed by GCMS
Data
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 39 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PAHs (PolyAromaticHydrocarbons) analytical flow chart
1) Name of the person who made measurement Dorothy Chen
2) Name of the person in charge of measurement Ray Chang
DATA
Sample pretreatment
Sample extracted (ultrasonic extraction) byToluene solvent
Analysis was performed by GCMS
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law
Page 40 of 40
Chemical Laboratory - Kao SGS Taiwan Ltd
Test Report No KA201811861 Date 20180206
FORMOSA PLASTICS CORPORATION
NO 100 SHUI-GUAN RD JEN-WU DIST KAOHSIUNG CITY TAIWAN (ROC)
PIC
End of Report
The tested sample part is marked by an arrow if its shown on the photo
SGS Taiwan Ltd台灣檢驗科技股份有限公司
No 61 Kai-Fa Road Nanzih Export Processing Zone Kaohsiung Taiwan 高雄市楠梓加工出口區開發路61號
t + 886 (07)301 2121 f + 886 (07)3010867 wwwtwsgscom
Member of the SGS Group
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested This test report cannot be reproduced except in full without prior written permission of the Company除非另有說明此報告結果僅對測試之樣品負責本報告未經本公司書面許可不可部分複製This document is issued by the Company subject to its General Conditions of Service printed overleaf available on request or accessible at wwwsgscomterms_and_conditionshtm and for electronic format documents subject to Terms and Conditions for Electronic Documents at wwwsgscomterms_e-documenthtm Attention is drawn to the limitation of liability indemnification and jurisdiction issues defined therein Any holder of this document is advised that information contained hereon reflects the Companyrsquos findings at the time of its intervention only and within the limits of Clientrsquos instructions if any The Companyrsquos sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents This document cannot be reproduced except in full without prior written approval of the Company Any unauthorized alteration forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law