JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Chapter 1 Product Information
1.1 naming rules
① series No. EC2N: EC2N series
② input and output points 20:12 points inputs; 8 points Output
③ Output Type MR: Relay output type;
MT: Transistor output type, with 2-channel high-speed;
MT (4G):Transistor output type, with 4-channel high-speed.
1.2 controllers constitute
Figure 1-1 Controller constitute
1.3 Basic parameters
Table 1-1 EC2N series programmable logic controller basic parameters
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
1.4 Performance Specifications Table 1-2 Performance Specificatio
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Chapter 2 Mechanical Design Reference
2.1 Installation dimensions
Figure 2-1 Mounting Dimensions schematic diagram (Unit: mm)
2.2 Installation location requirements
To prevent overheating inside the machine, use a normal wall mounting. Up and down as required Provide adequate space for heat dissipation.
Stay between the programmable controller host and other equipment or structures more than 50mm gap. Far away from power lines, high-voltage equipment and power equipment.
2.3 fixation methods
DIN slot fixed step
a.DIN mounting slot is level fixed on the backplane;
b.Pull out DIN slot card which is below the bottom of the PLC;
c.hang onto the PLC DIN, withhold the card back into place, locking PLC;
d. Finally, the two ends of the PLC and then slot the card file with DIN fixing to avoid sliding around. With
screw mounting: the presence of the impact of the occasion, it is recommended to use two M4 screws.
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Chapter 3 Electrical Design Reference
3.1 Hardware Interface 3.1.1 Terminals defined
Figure 3-1 Terminal definitions
3.1.2 Communication Interface Definition
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Round MD8 communication port is RS422 communication port, support FXPLC programming agreement,
exactly the same as FX2NPLC , You can complete the program download (using the SC-09 programming cable), text, touch screen or configuration king other software communications.
Figure 3-3 Terminal communication port
3.3 power supply circuit Specification
Controller with DC24V power supply, controller power dissipation is 15W.
3.4 Input Specifications
3.4.1 Input Specifications
Table 3-1 Input terminal specifications
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
3.4.2 Internal Equivalent Circuit
Controller with built-user detecting switch state power (DC24V), users only need access to a dry contact switch signal. To connect output signal of active transistor sensor is required NPN type sensor.
3.5 Output Specifications and external wiring Table 3-2 Output Terminal Specifications
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Relay output type output terminals are divided into several groups, each group is electrically isolated,output
contacts of different groups can access different power circuits.
Figure 3-5 Relay Output Equivalent Circuit
Table 3-3 Built-in high-speed counter inputs Allocation Table
[U]: Up-counting input [D]: down counting input [A]: A phase input. [B]: B phase input.
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Transistor output type output terminals are divided into several groups,each group is electrically isolated,
Output contacts of different groups can be connected to different power supply circuits.Transistor output stage
can only be used DC24V DC load circuits.
Note: Y0, Y1 point for both high-speed output,COM0 and COM1 internally short circuit (see Figure 3-
6);Y6,Y7 point for both high-speed output,COM3 and COM4 also short circuit internally;Y6, Y7 point for
both normal transistor output,Between COM3 and COM4 are electrically isolated.
Figure 3-6 Transistor output equivalent circuit
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
when MR-type PLC connected to inductive loads of AC circuit, external RC circuit should be considered
instantaneous voltage absorbing circuit,Corresponding to the DC circuit inductive load, you should consider
increasing the freewheeling diode. As shown below.
Figure 3-7 load protection circuit
The PLC has 4-channel high-speed pulse output capability,Supported send pulse command has PLSY, PLSR,
PLSV, ZRN, DRVI, DRVA.The maximum output frequency is 100K,allowing simultaneous output
independently of each other.Y point also allows multiple drivers, user-friendly editing.
Y0, Y1 support PWM command.
Table 3-4 special devices of PLSY, PLSR pulse command using
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Table 3-5 special devices of DRVI,DRVA pulse command using
Note:
1) The maximum frequency of PLSY, PLSR, ZRN, DRVI and DRVA pulse output instruction is 100KHz,if the
output pulse is higher than 10K, you must make M8149 = ON.when high-speed pulse output instruction
that FX2N PLC does not support,create FX1N projects, inputing 1N high-speed pulse output instruction
into the program,and then COPY to 2N project.
2) When Y0 is used for pulse output , M8080 to be set to OFF, you can not use DA0, DA1 analog output.
3) When Y6 is used for pulse output , X0 can not be used as a high speed counts input.
4) When Y7 is used for pulse output , X3 can not be used as a high speed counts input.
3.6 Network and network expansion MD306L text screen and PLC RS485 communication port wiring diagram:
Figure 3-13 Text communication lines
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
MT506 touch screen and PLC RS485 communication port wiring diagram:
above In the text and the touch screen software, select the PLC manufacturers, set up: Mitsubishi (FX series),
9600,7,1, even parity, 485; software variable settings and FX2N exactly the same.
Configuration king software communicate with PLC RS485 communication port
Wiring diagram (you can choose Mitsubishi protocol or MODBUS protocol to when communication with
KingView), select FX2N programming protocol, Communication settings with Japan FX2NPLC exactly the
same, if you select the MODBUS protocol, see the Web site information.
Figure 3-15 Communication with configuration software
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Multiple PLC network via MODBUS protocol
Figure 3-16 MODBUS protocol networking
Chapter 4 Programming Reference
Note: This series PLC applies to GX 8.52E and the following version (PC to install XP system);Support
Windows7 GXDeveloper version,but not read the program. Adds encryption features,Ordinary encrypted
passwords, confidential performance in general, with the serial communication software can be read out.If you
require a higher encryption, use strong encryption feature, the user password is set to 12345678, You
complete closure the function of reading the ladder program,thereby protecting the user program.In this
encrypted state, you can not modify user passwords and read out the ladder program, PLC Storage space can
be only cleared by position machine monitoring software to recover the non-encrypted state.
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
4.1 components number assigned and functions summary Table 4-1 Summary of Device Function
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
4.2 Special Component Description
Note: This series PLC does not support M8002 and M8003 pulse relay,please use the rising edge pulse
instructions LDP of M8000 to replace M8002a when necessary!
Table 4-2 Special Device Description
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
① When a syntax error, ERROR indicator will blink, by monitoring the M8065, D8065 can determine the
syntax error occurred step.
4.3 Instruction List
Table 4-3 27 basic sequence instructions
JingBiao Automation Co., Ltd.
Email : [email protected] Yahoo IM : arcozhang Skype : arcozhang.cn
Table 4-4 2 stepper Instruction
Table 4-5 Application instructions