www.lampslighting.co.uk
Challenger 66 LEDIndustrial Luminaires
The information given on these sheets is typical of the product depicted; it must not be interpreted as a guarantee of individual product performance and / or characteristics.We reserve the right to alter specif ications and designs without prior notice. All measurements are in millimetres (mm).
High Efficiency
2 x LED 17W 4000K (cool) - 4631 lm
2 x LED 24W 4000K (cool) - 6428 lm
High Output
2 x LED 25W 4000K (cool) - 6300 lm
2 x LED 36W 4000K (cool) - 8878 lm
Accessories
Trunking mounting clips – (2pk)
Standard
LLCC 2414
LLCC 2424
LLCC 2434
LLCC 2444
FLCTM 2
Emergency
E3-LLCC 2414
E3-LLCC 2424
E3-LLCC 2434
E3-LLCC 2444
MIC 1
ü
ü
ü
ü
MIC 3
ü
ü
ü
ü
MIC 2
ü
ü
ü
ü
Ordering Code MIC Compatibility p.3 DimensionsChallenger LED TwinL
1272
1572
1272
1572
W
145
145
145
145
D
111
111
111
111
FC
700
940
700
940
Challenger 66 LED Twin
Challenger 66 LED Twin 2 x 24W, 4000K – 6428lm
180° 150°150°
120°120°
90°90°
0° 30°30°
60°60°
cd / 1000 lmC0 / C180 C90 / C270
100
50
150
200
250W
D
FC
L
66These luminaires are designed to comply with:BS EN 60598–1Emergency BS EN 60598–2–22
Features:
Options:
Material:
Finish:
Spares
• IP66 (dust tight & strong water jet proof)• IK10 (20 joule) shock resistance• Corrosion resistant• Energy efficient Osram LEDs• Choice of four LED light outputs• High lumen output over 4 wattages – superior performance to a linear fluorescent – Up to 136lm/w• Average 50,000 hrs LED life - maintenance free• Optimum single bin LEDs with a 3 MacAdam ellipse tolerance• Stainless steel quick release clip on lens• Wall or ceiling mounting• 20mm side knockouts for through wiring
• Available with an integrated Manual Intelligent Control (MIC): / MIC1 MIC 1 / MIC2 MIC2 / MIC3 MIC 3• Integral 3hr maintained emergency• Single or twin versions available• Prismatic lens available on request: LLCP ***• Trunking mounting clips: /FLCTM 2
• Body: polycarbonate• Lens: polycarbonate
• Body: grey• Lens: cloud or prismatic (on request)
All components are available from Lamps & Lighting’s UK manufacturing facility.
Industrial Luminaires
Trunking MountingStainless Steel Clips
www.lampslighting.co.uk
The Manual Intelligent Control (MIC) system features a range of advanced sensor technology controls offering the ultimate in energy saving and carbon reduction. Significant energy savings can be achieved with a MIC system that dynamically manages lamp power according to the instantaneous lighting requirement. It ensures that the right level of light appears at the right place only when required, this preventing unnecessary energy consumption and potentially reducing maintenance costs. The MIC system has been installed in over 3000 BT telephone exchanges with confirmed energy savings in excess of 70%.
There are three types of Manual Intelligent Control: MIC1, MIC2 and MIC3, available as a master (sensor incorporated) or a slave (controlled by master), to suit different requirements and budgets. The manual intelligent controls are programmed manually by a dip switch to switch on and off automatically to maximise cost savings.
MIC 1
MIC 2
MIC 3
MIC 1 is a versatile and cost-effective OFF–ON–OFF energy saving control unit.
MIC 2 offers all the benefits of the MIC 1 but with a DIM–ON–DIM function. MIC 2 is an ideal control for reducing energy consumptions whilst still providing some level of illumination for extra safety.
MIC 3 is the most flexible energy saving manual control with an OFF–ON–DIM–OFF function, permitting full light management and maximum energy saving.
OFF ON DIM OFF
ONOFF
ONDIM
OFF
DIM
Absence – luminaires areswitched off.
Absence – luminaires areon at a courtesy preset dimmed level. Approximately 20% output and 1/3 total power.
Absence – luminaires are switched off.
Occupancy detected – luminaires illuminate at full output.
After a preset time of absence, luminaires dim to the courtesy preset dimmed level. Approximately 20% output and 1/3 total power
After continued absence over a preset time, luminaires switch off completely. If required, the ‘off’ function can be disabled to operate as a MIC 2
Occupancy detected –luminaires illuminate at full output unless there is sufficient daylight and the lux level setting overides it.
Occupancy detected –luminaires illuminate at full output.
Absence – after a preset time, luminaires switch off completely.
Absence – after a preset time of absence, luminaires return to the courtesy preset dimmed level.
Suffix LuminaireOrdering Code
Suffix LuminaireOrdering Code
Suffix LuminaireOrdering Code
Master
/MIC1
Slave
/MIC1S
Example –Challenger LED Single 1270mm with integrated MIC1 slave system: LLCP 1414/MIC1/s
Master
/MIC2
Slave
/MIC2S
Example –Challenger LED Single 1570mm with integrated MIC2 master system: LLCP 1514/MIC2
Master
/MIC3
Slave
/MIC3S
Example –Emergency Challenger LED Single 1270mm slave with integrated MIC3 master system: E3-LLCP 1414/MIC3
ONDIM DIM
Absence – luminaires areon at a courtesy preset dimmed level. Approximately 20% output and 1/3 total power.
Occupancy detected –luminaires illuminate at full output.
Absence – after a preset time of absence, luminaires return to the courtesy preset dimmed level.
MICManual Intelligent Control
The information given on these sheets is typical of the product depicted; it must not be interpreted as a guarantee of individual product performance and / or characteristics.We reserve the right to alter specif ications and designs without prior notice. All measurements are in millimetres (mm).
MIC 1
DIP Switch
0–2000 lux
N/A
5–30 mins
2–10 metres
N/A
360°
600W
MIC Operating Functions and Features
Operating function
Lux level adjustment
Time adjustment to courtesy preset dimmed level
Time adjustment to switch off completely
Sensitivity (range) adjustment
Dimming level (iLite ballast/driver)
Detection angle
Sensor maximum load (inductive)
MIC 2
DIP Switch
N/A
5–30 mins
N/A
2–10 metres
10/25/50%
360°
600W
MIC 3
DIP Switch
N/A
5–30 mins
10–30 mins
1–6 metres
10/25/50%
360°
600W
Option One
The masters are all working independently for maximum energy efficiency to create a cascade effect. This is ideal for a retrofit installation.
Option Two
The master is working in conjunction with a slave to illuminate a specific zone. The master will control the slaves.
Option Three
The masters and the slaves are working in conjunction to illuminate a larger area.
Option Four
The masters are working together for maximum energy efficiency and sensitivity in a zoned area.
Option Five
All masters are working together for maximum sensitivity and control of a complete area.
MIC 1 & 2 MIC 3
MICManual Intelligent Control
Detection Area
Typical Installation Options
Setting 1 =2metres Setting 2 = 5 metres Setting 3 =10metres
0
3.5
10 08 6 4 2 2 4 6 8 10
Detection area (metres)
Mou
ntin
g H
eigh
t (m
etre
s)
Sett ing 1 = 1 metre S ett ing 2 = 3 me tres S ett ing 3 = 6 me tres
0
8
10 08 6 4 2 2 4 6 8 10
Detection area (metres)
Mou
ntin
g H
eigh
t (m
etre
s)