Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
USER MANUAL
CDV-ENG-97-8ID-V1 / 201708
RF CARD
CDV97-8ID
CDV97-8ID Series
2 WIRE SYSTEM
8 Button Door StationWith Proximity Access Control & Fish Eye Camera
CONTENTS
PARTS AND FUNCTIONS ..................................................................................... 3Part Names............................................................................................................. 3
Mounting ................................................................................................................. 3
Terminal Description ............................................................................................... 4
BASIC FUNCTIONS .............................................................................................. 5Unlock Operations .................................................................................................. 5
Fisheye Camera ..................................................................................................... 5
SETUP INSTRUCTIONS ........................................................................................ 6Functions Setting Up .............................................................................................. 6
Setting Door Station Address ................................................................................. 7
Setting Camera N/P Standard ................................................................................ 8
Setting Prompt Voice .............................................................................................. 8
Setting Prompt Voice Volume ................................................................................. 9
Setting Unlock Mode .............................................................................................. 9
Setting Unlock Time............................................................................................... 10
Setting Nameplate Illumination Mode .................................................................... 10
Setting Night View LED Illumination Mode ............................................................ 11
Setting Ring-back Tone ......................................................................................... 11
Setting Image Display Mode.................................................................................. 12
Registering ID Card ............................................................................................... 13
Restore To Default ................................................................................................. 15
WIRING ................................................................................................................. 16Connecting Electric Lock ....................................................................................... 16
APPENDIX ............................................................................................................ 17Precautions............................................................................................................ 17
Specification .......................................................................................................... 17
Cables and Requirments ....................................................................................... 18
-3-
Part Names
PARTS AND FUNCTIONS
[9]
[10]
[11]
[12]
[8]
[7]
[6]
[5]
[1]
[3]
[4]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Speaker
Mounting
1 2 3 4 5
Rainy cover
The distance between the top of main unit and rain cover should be not less than 3mm.
Main unit
≥3mm
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
Main unit
The installation height is suggested to 145~160cm.
[7] Night view LED
[8] Camera lens
[9] Rain cover
[10] Mounting holes
[11] Connection port
[12] External key module
1. Drill holes in the wall to match the size of wall plugs, then attach the rain cover to the wall.
2. Connect the cable as per instructions and attach the main unit to the rain cover. The distance between the top of main unit and rain cover should not be less than 3mm.
-4-
PARTS AND FUNCTIONS
Lock Control Jumper: To select the lock type.
3P Connect Port: To button module.
Main Connect Port: To connect the bus line and the electronic locks.
• L1,L2: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power positive(power +).
• S+: Lock power(+) output.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door station to power the locks, if using the external power supply for the locks, the S- will not be connected).
1 2 3
Lock Control Jumper
3P Connect Port
+12V
GN
DP
IR
L1 L2 PL S+ S-Main Connect Port
Terminal Description
3. Install the name plate.
4. Attach the front panel to the rain cover.
5. Use the special screwdriver and the screws to fix the panel.
-5-
BASIC FUNCTIONS
Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the UNLOCK indicator lights up, the buzzer sounds,and the electric door strike is unlocked.
• If show the authorized user card,the buzzer will sound of beep+,and the UNLOCK indicator will light up.
• If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
Fisheye Camera
Please note that this function requires the monitorwithfisheyefunctiontosupport.
The angle view is 1700,visitors in this angle view can be seen clearly and can be zoomed to see individuals up close via indoor monitor withfisheyefunction.
Standarddoor station angle
DT6081700 door camera angle
(Wide angle view shown)
-6-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1KEY_2KEY_3KEY_4KEY_SET
LED_UNLOCKLED_CALL
LED_NAME
Main unit
RF CARD
This section explains the settings of each function, please refer to the following table:
To perform the settings for the function you want,you should move away the metal front panel. Please refer to the sketch map.
Each operation is indicated by the lighting up of the LED indicator on the unit, and by the sounding of the buzzer.
Order Setting items Setting range Default value
4 Setting prompt voice volume 1~9 6
7Setting the nameplate
illumination modeOn/Off/Auto On
8Setting night view LED
illumination modeOn/Off/Auto Auto
Ringing one time
10 Setting image display modeAlternate switching mode
Zoom modeFull screen mode
Alternate switching mode
6 Setting the unlock time 01 to 99 seconds 5 seconds
6 Setting the unlock mode 0:opened
2 Setting camera N/P standard NTCS or PAL standard PAL standard
1 Setting door station address 0~3(DS 1 to 4) 0
3 Setting prompt voice Max. 2 Settings - Off or On Voice prompt On
Ring once10 Setting ring-back tone Ring continuously No ring-back tone
-7-
Setting Door Station Address
UNLOCK Indicator:OFFTALK Indicator:OFF
Buzzer Beep+, Beep
UNLOCK Indicator:OFFTALK Indicator:OFF
Buzzer Beep+
In standby mode, press KEY_SET button once
Press KEY_1 button to set the first door station.
Press KEY_2 button to set the second door station.
Press KEY_3 button to set the third door station.
Press KEY_4 button to set the fourth door station.
UNLOCK Indicator:OFFTALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFFTALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFFTALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
SETUP INSTRUCTIONS
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
A total of 4 addresses can be configured. The address can be modified either before or
after installation. 0 (DS #1) is default, to change the address, please use the following
steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the address of door station can be changed by pressing KEY1~4 cyclically.• The LED_NAME indicator will continually flash while in the setting mode.
-8-
Setting Prompt Voice
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press KEY_SET button twice.
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Play the voice 1
Press KEY_3 button to set the prompt voice to Voice 1.
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Play the voice 2
Press KEY_3 button again to set the prompt voice toVoice 2.
Press KEY_3
SETUP INSTRUCTIONS
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press KEY_SET button twice.
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set thecamera standard to P standard.
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again to set the camera standardto N standard.
Press KEY_2
P (PAL) standard is default, to change the setting, please follow the steps:
The video standard of the camera can be changed at any time, that means the quality of image on screen can be set to differ.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changed by pressing KEY2 cyclically.• The LED_NAME indicator will continually flash while in the setting mode.
There are 2 options Voice prompt on or off. On is default; to change
the setting please use the following steps:
Beep+
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer
Press KEY_3 button again and again to set the promptvoice to No voice.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changed by pressing KEY3 cyclically.• The LED_NAME indicator will continually flash while in the setting mode.
-9-
SETUP INSTRUCTIONS
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press KEY_SET button twice.
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Play the volume
Press KEY_4 button to set the volume level.
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer
Press KEY_4
Play the volume level 9
Press KEY_4 button again and again to set the volumelevel you want.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press KEY_SET button three times.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set the unlock mode to Normally opened.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button againto set the unlock mode to Normally closed.
Press KEY_1
Setting Prompt Voice Volume
A total of 9 volume levels can be configured. The levels can be modified either
before or after installation. 6 is default; to change the setting please use the
following steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the volume level can be changed mode by pressing KEY4 cyclically.• The LED_NAME indicator will continually flash while in the setting mode.
Setting The Unlock Mode
There are 2 unlock modes, Normally open and Normally closed. Normally opened
is default, to change the setting, please use the following steps:
• While in the setting mode, the calling mode can be changed by pressing KEY1 cyclically.• The LED_NAME indicator will continually flash while in the setting mode.•
e setting mode manually press the KEY_If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit th SET button four times.
-10-
Setting Nameplate Illumination Mode
Setting Unlock Time
SETUP INSTRUCTIONS
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press KEY_SET button three times.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2 button. The time you holdingon is the new unlock time.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press KEY_SET button three times.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+
Press KEY_3 button to set the nameplate illumination mode to Normally on.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_3 button againto set the nameplate illumina-tion mode to Normally off.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_3 button again and again to set the nameplate illumination mode to Auto.
Press KEY_3
By default the unlock time is 1s, this can be changed from 1s~99s. To change the unlock
time please use the following steps:
• When holding button 2 to set the unlock time, the buzzer will sound one time every second• The LED_NAME indicator will flash continually while in the setting mode.
• If no operation is carried out within 10 s the setting mode will exit automatically.• Press KEY_SET button twice to exit out the setting mode manually.
There are 3 illumination modes for the nameplate indicator, Normally on,Normally off and
Auto. Normally on is default, to change the setting, please follow the steps:
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3 cyclically.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• The LED_NAME indicator will continually flash while in the setting mode.
-11-
Setting Ring-back Tone
Setting Night View LED Illumination Mode
SETUP INSTRUCTIONS
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press KEY_SET button three times.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+
Press KEY_4 button to set the night view LED mode to Normally on.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_4 button againto set the night view LED mode to Normally off.
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_4 button againand again to set the night view LED mode to Auto.
Press KEY_4
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press KEY_SET button four times.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+
Press KEY_1 button to set the ring-back call tone ringingone time.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button againto set the ring-back call tone ringing continuously.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep, Beep,Beep
Press KEY_1 button againand again to close ring-backcall tone.
Press KEY_1
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
There are 3 working modes for night view LED indicator, Normally on,Normally off and Auto.
Auto is default, to change the setting, please follow the steps:
• While in the setting mode, the illumination mode can be changed by pressing KEY4 cyclically.• The LED_NAME indicator will continually flash while in the setting mode.
Press the call button to call the monitor, a ring-back call tone can be heard from door station.
There are 3 ring-back call tones, Ring once, Ring continuously and No ring-back tone.
Ringing one time is default, to change the setting, please follow the steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changed by pressing KEY1 cyclically.• The LED_NAME indicator will continually flash while in the setting mode.
-12-
Setting Image Display Mode
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press KEY_SET button four times.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set the image display mode to Cycle switching.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button againto set the image display mode to Zoom mode.
UNLOCK Indicator:ONCALL Indicator:ON
Press KEY_2
Buzzer Beep, Beep,Beep
Press KEY_2 button againand again to set the image display mode to Full screen.
During setting mode, press KEY-2 to switch Cycle switching mode, Zoom mode and Full screen mode in cycle.
SETUP INSTRUCTIONS
When answering the call
Please note this setting is only for monitors that do not support manual pan, tilt and zoom functions, i.e. CDV47M, CDV43 & CDV24.
When calling a monitor:When a call is placed from door station to a monitor, the image is displayed on screen. There are 3 modes for the image that can be displayed; Alternate switching mode, Zoom mode and Full screen mode.
Alternate switching mode: when the monitor is called, the image will switch between Full screen and Zoom image at a time interval of 5 seconds.
Full screen mode: when the monitor is called, the image will be displayed in Full screen.
Zoom mode: when the monitor is called, the image will be displayed on full screen for 5 seconds, then switch to Zoom image.
Alternate switching mode is the default. To change the setting, please use the following steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling code can be changed mode by pressing KEY 2 cyclically. • The LED_NAME indicator will continually flash while in the setting mode.
When answering the call, the image switching reminder can be activated or deactiviated.
Alternate switching mode: When answering the call, image switching reminder is not shown.
Zoom mode: When answering the call, the image will be displayed on full screen for 5 sec-onds, then switch to Zoom image as a reminder to enter the talk status.
If set to activated, the image switching reminder will be different for each image display mode, see below.
-13-
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press KEY_SET button four times.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+
Press KEY_3 button to activate image switching when answering the call.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep, Beep
Press KEY_3 button againto forbid image switchingwhen answering the call.
Press KEY_3
SETUP INSTRUCTIONS
Registering ID Card
By default there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE , new master cards can be authorised by users at any time.This means any two user cards can be authorised as master cards. When registered new master cards, the exisiting master cards will be invalidated automatically.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling code can be changed mode by pressing KEY 3 cyclically. • The LED_NAME indicator will continually flash while in the setting mode.
Full screen mode: When answering the call, the image will be displayed on Zoom mode for 5 seconds, then switch to Full screen as a reminder to enter the talk status.
If deactivated, no image switching reminder is displayed on any image display mode.
Activated is default, to change the setting, please use the following steps:
• Card reading distance is less than 3cm.
• EM card, 125kHz.
• Cards = Tags
• A maximum of 320 user cards can be registered by the door station.
• Straight forward management with LED status and sound hints.
• There are two master cards, one MASTER CARD ADD and one MASTER CARD DELETE. When registering new master cards the exisiting master cards are invalidated automatically.
• The master cards are necessary when you add or delete user cards. Please keep safe for future use.
Authorising master cards:
-14-
SETUP INSTRUCTIONS
UNLOCK Indicator:Blink two timesCALL Indicator:OFF
Buzzer Beep,Beep
Show the first card to ID card window, set the card of MASTER CARD ADD.
UNLOCK Indicator:Blink three timesCALL Indicator:OFF
Buzzer Beep,Beep,Beep
Show the second card to ID card window, set the card of MASTER CARD DELETE.
UNLOCK Indicator:OFFCALL Indicator:OFF
Buzzer Beep+, Beep
When power on in 10s,pressand hold on KEY_SET buttonfor 3s.
UNLOCK Indicator:Blink one timeCALL Indicator:OFF
Buzzer Beep+
Press KEY_2 button.
Switching Access Control:
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of MASTER CARD ADD to ID card window in standby.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of MASTER CARD DELETE to ID card window.
UNLOCK Indicator:OFFCALL Indicator:OFF
Buzzer Beep+
Show the master card of MASTER CARD DELETEagain to switch as a door station access control.
UNLOCK Indicator:OFFCALL Indicator:OFF
Buzzer Beep,Beep
Show the master card of MASTER CARD DELETEagain to switch to DT-ACCcontrolled.
Adding User Cards:
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of MASTER CARD ADD to ID card window in standby.
UNLOCK Indicator:OFFCALL Indicator:Blink one time
Buzzer Beep+
Show user cards to be added in sequence.
UNLOCK Indicator:OFFCALL Indicator:OFF
Buzzer Beep, Beep+
Show the master card of MASTER CARD ADD again to exit.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• The door station will exit the setting mode after showing both cards, The UNLOCK & TALK will turn off.
• The LED_NAME indicator will continually flash while in the authorisation mode.
• If no operation is carried out within 10 seconds,
ontrolled by CDV-A
the setting mode will exit automatically.
• If current access is controlled by door station, the next access setting will c CC.
• If
ation muno operation is carried out within 10 seconds, the setting mode will exit automatically.
• To add user cards the door st st be set for access. See above.
-15-
SETUP INSTRUCTIONS
Initializing Access (delete all user cards):
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+, Beep
Show the master card of MASTER CARD DELETE to ID card window in standby.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+, Beep
UNLOCK Indicator:Blink for some time
CALL Indicator:Blink for some time
Buzzer Beep
Show the master card of MASTER CARD ADD again,format is activated.
Show the master card of MASTER CARD ADD to ID card window.
Deleting User Cards:
UNLOCK Indicator:ONCALL Indicator:OFF
Buzzer Beep+, Beep
Show the master card of MASTER CARD DELETE to ID card window in standby.
UNLOCK Indicator:Blink one timeCALL Indicator:OFF
Buzzer Beep+
Show user cards to be deleted in sequence.
UNLOCK Indicator:OFFCALL Indicator:OFF
Buzzer Beep, Beep+
Show the master card of MASTER CARD DELETE again to exit.
Restore To Default
UNLOCK Indicator:OFFCALL Indicator:ON
Buzzer Beep+, Beep
When power on in 10s,pressand hold on KEY_SET buttonfor 3s.
UNLOCK Indicator:ONCALL Indicator:ON
Buzzer Beep+
Press KEY_3 button.
• If no operation is carried out within 10 seconds, the setting mode will exit automatically.
• To add user cards the door station must be set for access. See page 14.
• When formatting is finished, UNLOCK & TALK indicator will turn off , a “ Beep+ ” will be heard, and door station will exit the setting mode automatically.
• To add user cards the door station must be set for access. See page 16.• At step 3, the UNLOCK & TALK indicator will flash constantly until formatting is finished.
• If no operation is carried out within 10 seconds, the setting mode will exit automatically.
The 'restore to default' function allows the user to recover the factory settings.
• The LED_NAME indicator will blink twice per second while in the 'restore to default' mode.
• If no operation is carried out within 10 seconds, the setting mode will exit automatically.
• When restoring is completed, UNLOCK & CALL indicator will be turn off and the setting mode will exit automatically.
-16-
Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
1.The external power supply must be used according to the lock.
2.The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before connecting.
4.Setup the Unlock Mode according to different lock types.
• Power-on-to-unlock type:Unlock Mode=0 (by default)
• Power-off-to-unlock type:Unlock Mode=1
EB*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER SUPPLY
WIRING
3.The jumper should be placed on position 2 and 3 before connecting.
1.Electronic lock of Power-on-to-unlock (fail Secure) type should be used.
4.The door lock control is not timed from Exit Button(EB).
2.The door lock is limited to 12V, and hold- ing current must be less than 250mA.
5.The Unlock Mode is set to 0 (by default).
* CDV-RLC relay actuator is required for 2nd lock connection.
-17-
Precautions
Specification
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
APPENDIX
• Pay attention to the high voltage inside the products, please refer service only to a trained andqualifiedprofessional.
● Power Supply :
12Vdc, 250mA(Internal Power);
● Unlock time: 1~99s(Default 1s);
● Number of relay circuits: 2 (the second lock need external
● device to support);
● Working temperature: -20ºC ~ +55ºC;
● Wiring: 2 wires,non-polarity;
● Protection: IP45;
● Dimension: 281(H)×110(W)×44(D)mm.
● Lock Power supply:
DC 24V;
● Power Consumption: Standby 1.2W; Working status 4.8W;
● Fish Camera: Color CMOS, 2.0 Mega pixel 1/2.7’’
fisheye camera,170° wide angle(CDV97);
-18-
APPENDIX
Cables and Requirments
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.
Cable and distance(unit:m)
A
B
PC6A
RF CARD
Basic IN-OUT Wiring Mode
Cable Usage A B
≤2 IM
B
≤16 IM
Belden 9470 UTP 2x0.75mm2 60 100 40 Belden 8471 UTP 2x1mm2 80 120 60
-19-
B
A
C2
2
DBC4A1
PC6A
RF CARD
Cable and distance(unit:m)
APPENDIX
Star Topology Wiring Mode With DBC4A1
Cable Usage A B C
Belden 9740 UTP 2x0.75mm2 60 60 30
Belden 8471 UTP 2x1mm2 80 80 40
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.