    1/2

    Isolated between input-outputBuilt-in overcurrent and overvoltage protection circuits

    Built-in remote ON/OFFUL, C-UL recognized, TÜV approvedFive-year warranty

    ¡ ORDERING INFORMATION

    CBS2004812-

    Oputional: EX. Remote ON/OFF  (Positive logic) : R  Mounting hole  (º3.4 thru) : TOutput voltageInput voltage

    48 : DC36~76VOutput wattageSingle outputSeries name

    CBS200

    CBS SERIES DC/DC CONVERTER

    VOLTAGE

    CURRENT

    EFFICIENCY

    VOLTAGE

    CURRENT

    LINE REGULATION

    LOAD REGULATION

    RIPPLE

    [mVp-p]¶2

    [mVp-p]¶2

    TEMPERATURE

    REGULATION [m V]

    DRIFT

    START-UP TIME

    REMOTE SENSING

    REMOTE ON/OFF

    INPUT-OUTPUT

    INPUT-CASE,BASE PLATE

    OUTPUT-CASE,BASE PLATE

    VIBRATION

    IMPACT

    200 max (DCIN 48V, lo =100%)

    Fixed(TRM pin open), 60~110% adjustable by external resistor

    Works over 105% of rating and recovers automatically

    Provided

    Provided(Negative logic L:ON, H:OFF)

    DC1,500V 1minute or AC1,000V 1minute, Cutoff curreut=10mA, DC500V 50MΩmin(20±15ª)

    DC1,500V 1minute or AC1,000V 1minute, Cutoff curreut=10mA, DC500V 50MΩmin(20±15ª)

    AC500V 1minute, Cutoff current=100mA, DC500V 50MΩmin(20±15ª)

    -40~100:(On aluminum base plate), 20~95%RH(Non condensing)(Refer to DERATING CURVE), 3,000m(10,000feet)max

    -40~100:, 20~95%RH(Non condensing), 9,000m(30,000feet)max

    10~55Hz, 49.0m/s2(5G), 3minutes period, 60minutes each along X, Y, Z axis

    196.1m/s2(20G), 11ms once each along X, Y, Z axis

    UL 1950, C-UL, EN60950

    [V]

    [A]¶1

    [%]¶1

    [V]

    [A]

    [mV]

    [mV]

    –20~+100 C̊

    –40~–20 C̊

    –20~+100 C̊

    –40~–20 C̊

    0~+65 C̊

    –40~+100 C̊

    [mV]¶3

    [ms]

    [V]¶4

    [V]

    [V]OVERVOLTAGEPROTECTION

    OVERCURRENTPROTECTION

    OUTPUT VOLTAGESETTING

    OUTPUT VOLTAGEADJUSTMENT RANGE

    MODEL

    INPUT

    OUTPUT

    ISOLATION

    PROTECTION

    CIRCUIT AND

    OTHERS

    SAFETY

    ENVIRONMENT

    SPECIFICATIONS

    RIPPLENOISE

    AGENCY APPROVALS

    CBS2004805

    3.77typ

    83typ

    5

    30.0

    10max

    10max

    80max

    120max

    120max

    200max

    50max

    100max

    20max

    3.0~5.5

    4.90~5.20

    5.75~7.00

    1.98~3.63

    3.25~3.45

    4.00~5.50

    7.2~13.2

    11.74~12.46

    13.80~16.80

    9.0~16.5

    14.55~15.45

    17.25~21.00

    16.8~30.8

    27.16~28.84

    32.20~39.20

    CBS2004824

    4.77typ

    88typ

    24

    8.4

    48max

    48max

    120max

    150max

    150max

    250max

    240max

    480max

    90max

    CBS2004803

    3.01typ

    80typ

    3.3

    35.0

    10max

    10max

    80max

    120max

    120max

    200max

    35max

    66max

    16max

    CBS2004815

    4.76typ

    88typ

    15

    13.4

    30max

    30max

    120max

    150max

    150max

    200max

    150max

    300max

    60max

    CBS2004812

    4.74typ

    88typ

    12

    16.7

    24max

    24max

    120max

    150max

    150max

    200max

    120max

    240max

    40max

    CBS2004828

    4.77typ

    88typ

    28

    7.2

    56max

    56max

    120max

    150max

    150max

    250max

    280max

    560max

    90max

    14.4~26.4

    23.28~24.72

    27.60~33.60

    ¶1 A t rated inp ut(D C 48V ) and rated load .¶2 R ipp le and ripp le noise is m easured by using m easu ring bo ard w ith reco m m ende d cap acitor C o & the film capa citor 0.1µF.  M easured by 20M H z oscilloscop e or Ripp le-N oise m eter (Eq uivalent to KE ISO K U -G IK EN :R M 101).¶3 D rift is the change in D C output for an eight hour period after a half-hour w arm -up at 25ª, w ith the inp ut voltag e h eld constan t at the rated inp ut/ou tput.¶4 W hen the input voltage is in the rang e of D C 36~ 40V ,output voltage adjustm ent rang e is 60% ~ 105% .

    OPERATING TEMP.,HUMID. AND ALTITUDE

    STORAGE TEMP. ,HUMID. AND ALTITUDE

    (LVD)

    R

    DC36~76

    CBS-5

    BS

  • 8/19/2019 cbs200

    2/2

    MAX OUTPUTWATTAGE

    CBS2004828

    201.6W28V 7.2A

    CBS2004824

    201.6W24V 8.4A

    CBS2004815

    201.0W15V 13.4A

    CBS2004812

    200.4W12V 16.7A

    CBS2004805

    150.0W5V 30A

    CBS2004803

    115.5W3.3V 35A

    MODEL

    DC OUTPUT¡EXTERNAL VIEW

    DC/DC CONVERTER(SINGLE OUTPUT)

    +VOUT

    +STRM

    -S

    -VOUT

    4-M3

    (4.8)

       (   5 .

       1   )

       6   1    m    a    x

    57.9max

       1   0 .

       1   6

       1   5 .

       2   4

       1   0 .

       1   6

       1   0 .

       1   6

       7 .

       6   2

       7 .

       6   2

       1   0 .

       1   6

    -VIN

    CASE

    RC

    +VIN

       [   0 .

       3   ]

       7 .

       6   2

       7 .

       6   2

       [   0 .

       3   ]

       [   0 .

       4   ]

       [   0 .

       4   ]

       1   0 .

       1   6

       1   5 .

       2   4

       1   0 .

       1   6

       [   0 .

       6   ]

       5   0 .

       8

       [   2 .

       0   ]

    4-º3.5

    48.3

    [1.9]

    7-º1.5

    2-º2.5

    ¶Recomending size for processing PCB(TOP VIEW)

    Lot No.

    Case(PBT)

    Base Plate(Aluminum)

       1   2 .

       7

           ±   0 .

       5

       5 .

       0   8

           ±   0 .

       5

       5   0 .

       8

           ±   0 .

       5

    48.3  ±0.52-º2

    7-º1

    ¶Weight : 83g or less¶Tolerance : ±0.3¶Case : PBT¶Base Plate: Aluminum¶Dimensions in mm.¶Mounting hole screwing torque  : 0.4N•m(5.0kgf•cm)max

    ¶Dimensions :

    ¶Div. : 0.5inch

    mm[inch]

    Mounting Hole

    Name Plate

    CBS-6

    CBS