Upload
sorel-enegy
View
217
Download
1
Tags:
Embed Size (px)
DESCRIPTION
Project Data: IS TERED ARCH I T E C T S T A TE O F TE X A S 100 Jackson Suite 130 C voice: 713.527.0527 Houston , Texas 77002 [email protected] Single Family Residence: Living Area 2,473 sq.ft. Porch Area 1,195 sq.ft. Back Porch Area 521 sq.ft. REG SYMBOLS AND ABBREVIATIONS Specifications A1.10 A2.11 A2.21 A3.11 A3.12 A4.11 A4.12 A4.21 A4.22 A4.23 A5.10 A6.10 A6.11 A6.12 A7.10 ARCHITECTURAL GENERAL G1.10 G3.10 M ichae l R . K e lle r cat spring texas 18068
Citation preview
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
ISSSUED 20th october 2009
100 Jackson Suite 130 C voice: 713.527.0527Houston , Texas [email protected]
esplanade
GENERAL
G1.10
G3.10
SYMBOLS AND ABBREVIATIONS
Specifications
ARCHITECTURAL
A1.10
A2.11
A2.21
A3.11
A3.12
A4.11
A4.12
A4.21
A4.22
A4.23
A5.10
A6.10
A6.11
A6.12
A7.10
Site Plan
1st FLOOR PLAN
1st FLOOR RCP
Building Elevations
Building Elevations
Building Sections
Building Sections
Framing & Water Proofing
Framing Details
Framing Details
Green Technology
Foundation Plan
Sections & Specs
Pier & Sill Details
Interior Elevations
Texas CottageCat Spring, Texas
Project Data:Single Family Residence:
Living Area 2,473 sq.ft. Porch Area 1,195 sq.ft.
Back Porch Area 521 sq.ft.
Project Address:cat spring texas
Scope of Work:This project is for a new single family dwelling. It will have1 story be raised off the ground with a pier and sill foundation.
Coordination Statement:Pursuant to 22 TAC 1.103, an architect's seal on the work of anyconsultant(s) retained by the architect attests only to the architect'scooridination of the consultant's work with that of the architect's anddoes not imply the architect's practice of the consultant's specialty.
Sheet Index
G3.10
Thursday, April 22, 2010 1:21 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
183
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Specifications
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
16.5
16.4
16.3
16.2
16.1
15.19
15.18
15.17
15.16
15.15
15.14
15.13
15.12
15.11
15.10
15.9
15.8
15.7
15.6
15.5
15.4
15.3
15.2
13.3
13.2
13.1
11.3
11.2
11.1
10.1
9.10
9.8
9.7
9.6
9.5
9.4
9.3
9.2
Division 16: Electrical
15.1
Division 15: Mechanical
Division 14: Conveying Systems
Division 13: Special ConstructionDivision 12: Furnishings
Division 11: Equipment
Division 10: Specialties
Division 9: Finishes9.1
8.6
8.5
8.4
8.3
8.2
8.1
Division 8: Doors and Windows
7.8
7.7
7.6
7.5
7.4
7.3
7.2
7.1
Division 7: Thermal and Moisture Protection
6.15
6.14
6.13
6.12
6.11
6.10
6.9
6.8
6.7
6.6
6.5
6.4
6.3
6.2
6.1
5.5
Division 6: Wood
5.3
5.2
5.1
4.6
Division 5: Metals
4.5
4.4
4.3
4.2
4.1
3.8
Division 4: Masonry
3.7
3.6
3.5
3.4
3.3
3.2
3.1
Division 3: Concrete
2.9
2.8
2.7
2.6
2.5
2.4
2.3
2.2
2.1
Division 2: Sitework
1.2
1.16
1.15
1.14
1.13
1.12
1.11
Division 1: General Requirements
and SpecificationsGeneral Requirements
1.10
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.1ALL SITE WORK SHALL BE DONE PER THE GOVERNING AUTHORITY'SCODES, ORDINANCES AND STANDARDS.
VERIFY ANY DEMOLITION AS NECESSARY TO PROCEED WITHCONSTRUCTION OF THE PROJECT. DEMOLITION SHALL INCLUDETEMPORARY UTILITIES, DEMOLITION PERMITS, PROTECTION OF FENCES,TREES AND STRUCTURES TO REMAIN, INCLUDING THOSE ON ADJACENTPROPERTIES, AND CONTROL OF NOISE, DUST, AND DEBRIS.
ALL SITE PREPARATION FOR BUILDING FOUNDATION SHALL TAKE PLACEBASED ON REQUIREMENTS SET FORTH BY THE GEOTECHNICALINVESTIGATION AND A THOROUGH UNDERSTANDING OF THE ENGINEER'SCONSTRUCTION DOCUMENTS. CONTRACTOR SHALL PROVIDE ALLCONSTRUCTION SURVEYING AND STAKING TO PROPERLY LOCATE THESTRUCTURE ON THE SITE. THE CONTRACTOR IS RESPONSIBLE FORENSURING THAT THE SURVEY DOCUMENT IS ACCURATE AND CORRECTPRIOR TO PLACING FOUNDATION FORMWORK.
ESTABLISH AND CONFIRM THE FINISHED SLAB ELEVATION AND INSURETHAT IT IS TWELVE (12) INCHES ABOVE THE NEAREST MANHOLE COVER.
ALL SITE PREPARATION FOR BUILDING FOUNDATION, PORCHES,DRIVEWAYS, SIDEWALKS, OTHER FLATWORK, WALLS, AND FENCES SHALLPROMOTE POSITIVE DRAINAGE AWAY FROM BUILDING FOUNDATION. ALLDRAINAGE AND RUNOFF SHALL BE DIRECTED TO THE STREET. TYPICALSLOPES FOR DRIVEWAYS, SIDEWALKS AND EXTERIOR PATIOS SHALL BE AMINIMUM OF 1% AND A MAXIMUM OF 5%. CROSS SLOPES ATSIDEWALKS AND DRIVEWAYS SHALL NOT EXCEED 2%.
ALL UNPAVED AREAS SHALL BE LANDSCAPED AND GRADED TO PROMOTEPOSITIVE DRAINAGE AWAY FROM BUILDING FOUNDATION.
DETERMINE LOCATION OF EXISTING SITE UTILITIES (SANITARY SEWER,WATER, ELECTRICAL, GAS) AND SECURE CONNECTION PERMIT FROMAPPROPRIATE UTILITY SERVICE COMPANIES.
PROVIDE ALL REQUIRED CURB CUTS, SUB-BASE, DRIVEWAYS, PARKINGAREAS, AND OTHER PAVING. CONTRACTOR SHALL PROVIDE ALLREQUIRED FENCING, GATES, AND OTHER ENCLOSURES AND MATERIALS.
ALL AREAS TO RECEIVE LANDSCAPING SHALL BE PROVIDED WITH AMINIMUM 8" DEPTH OF TOPSOIL, SMOOTHLY GRADED TO SLOPE AWAYFROM BUILDING.
CONCRETE SHALL BE 5-SACK MIX, MINIMUM 3000 PSI COMPRESSIVESTRENGHT AT 28 DAYS AND 45 INCH SLUMP IN STANDARD CYLINDER.REINFORCING STEEL IS ASTM A-615 GRADE 60 WITH A-305DEFORMATIONS DETAILED AND INSTALLED AS PER ACI CODE. CHAIRSSHALL BE GALVANIZED WITH PLASTIC TIPS OR ALL PLASTIC. USEUTILITY GRADE FIR OR BETTER FOR FORM BOARDS.
PROVIDE ALL REQUIRED FOUNDATIONS, GRADE BEAMS, PIERS, ANDFLATWORK TO COMPLETE THE PROJECT IN STRICT ACCORDANCE WITHTHE REQUIREMENTS OF THE GEOTECHNICAL INVESTIGATION ANDENGINEER'S CONSTRUCTION DOCUMENTS.
VERIFY ALL REQUIRED FOUNDATION DROPS OR RECESSES FORFIREPLACES, ELEVATORS, GARAGE, AND SPECIAL FLOORING.
RECESS FOUNDATION 6" AT PREFAB FIREPLACE AND 3" FOR MATERIALAT FLUSH HEARTH.
THRESHOLD RECESS AT ALL EXTERIOR DOORS SHALL BE 3 1/2" U.N.O.
SLOPE FINISHED FLOOR AT GARAGE AND EXTERIOR COVERED AREASAWAY FROM THE BUILDING FOR DRAINAGE.
VERIFY THE MINIMUM FINISHED SLAB ELEVATION TO COMPLY WITH THEREQUIREMENTS OF THE GOVERNING AUTHORITY AND THE DESIGN INTENT.
CONCRETE SLAB SHALL RECEIVE A SMOOTH TROWELED FINISH.EXTERIOR SIDEWALKS AND DRIVEWAYS SHALL RECEIVE A LIGHT BROOMFINISH.
PROVIDE ALL REQUIRED MASONRY TO COMPLETE THE PROJECT.
ALL MASONRY, INCLUDING BRICK, CONCRETE MASONRY,, STONE, CASTSTONE, CONCRETE PAVERS, AND RELATED MATERIALS SHALL BEINSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS ANDAPPLICABLE CODES.
ALL MORTAR IS ASTM 270, TYPE S, 1 PART CEMENT, 1/2 PARTHYDRATED LIME, 34 1/2 PARTS SAND.
ALL MASONRY VENEER WALLS TO BE INSTALLED WITH WALL TIES AT 24"o.c. HORIZONTALLY AND 16" o.c. VERTICALLY. PROVIDE WEEP HOLESAT 24" o.c. AT BASE OF WALL AND ABOVE ALL OPENINGS.
PROVIDE STEEL LINTELS AT MASONRY OPENINGS AS INDICATED INDIVISION 5.
MASONRY FIREPLACES SHALL BE CONSTRUCTED WITH FIREBRICK, STONEHEARTH, STEEL DAMPER, SMOKE CHAMBER, CLAY TILE FLUE, ANDMASONRY CHIMNEY ACCORDING TO THE LATEST AMI STANDARDS.
PROVIDE ALL REQUIRED STRUCTURAL STEEL MEMBERS AND RELATEDPLATES, GUSSETS, BOLTS, SCREWS, JOISTS HANGERS, WELDS, ETC. TOCOMPLETE THE PROJECT IN STRICT ACCORDANCE WITH THE ENGINEER'SCONSTRUCTION DOCUMENTS AND APPLICABLE CODES.
ALL HOT-ROLLED STEEL SHAPES SHALL CONFORM TO ASTM A-36,STEEL PIPE TO ASTM A501. GALVANIZED STEEL SHALL CONFORM TOASTM A525, G90. ALL WELDS SHALL BE GROUND SMOOTH WHENEXPOSED TO VIEW AND ALL STEEL FABTICATIONS SHALL CONFORM TO AMINIMUM OF CLASS 2.
ALL JOIST HANGERS, STRAP TIES, HURRICANE ANCHORS, TO BEINSTALLED IN ACCORDANCE WITH ENGINEER'S CONSTRUCTIONDOCUMENTS AND MANUF. INSTRUCTIONS.
CONSTRUCTION DOCUMENTS: CONSIST OF DRAWINGS, SPECIFICATIONSAND NOTES. IN THE EVENT OF A DISCREPANCY, THE SPECIFICATIONSAND NOTES SHALL GOVERN AS TO THE WORK TO BE COMPLETED.
DRAWINGS: THE DRAWING SET IS ARRANGED FROM THE GENERAL TOTHE SPECIFIC, FROM THE OVERALL VIEW TO THE DETAILED VIEW. THEDRAWINGS ARE TITLED ACCORDING TO LOCATION IN THE PROJECT ANDTYPE OF DRAWING. GENERALLY, THE DETAIL DRAWINGS ARE NOTREFERENCED TO THE OVERALL VIEWS WHEN THEIR TITLE SUFFICIENTLYDESCRIBES THEIR LOCATION IN THE PROJECT. UNLESS OTHERWISEINDICATED, INDIVIDUAL DRAWINGS ARE THE SAME SCALE AS NOTED INTHE TITLE BLOCK OF THE SHEET OF WHICH THE DRAWINGS I
CODES: THE PROJECT SHALL BE COMPLETED IN STRICT ACCORDANCEWITH ALL APPLICABLE CODES, LATEST REVISIONS AND SUPPLEMENTS,INVOLVING THE INTERNATIONAL BUILDING CODE, THE INTERNATIONALRESIDENTIAL CODE, THE NATIONAL ELECTRICAL CODE, THE TEXASMUNICIPAL LEAGUE PLUMBING CODE, THE N.F.P.A. 90A & N.F.P.A. 90BCODES FOR HVAC SYSTEMS, THE INTERNATIONAL FIRE CODE, ANDAPPLICABLE STANDARDS PROVIDED BY THE CONSTRUCTION CODE OF UL(UNDERWRITERS LABORATORIES INC.) ALL WORK SHALL BE INACCORDANCE WITH THE REQUIREMENTS OF THE GOVERNING AUTHORITIESREGARDLESS OF INFORMATION SHOWN IN THE CONSTRUCTIONDOCUMENTS.
COMPLETION OF WORK: CONTRACTOR SHALL FURNISH ALL LABOR,MATERIALS, AND EQUIPMENT NECESSARY TO COMPLETE THE INTENT OFTHE ENTIRE PROJECT, INCLUDING BUT NOT LIMITED TO ALL INTERIORAND EXTERIOR FINISHES, MECHANICAL, ELECTRICAL, PLUMBING, MOISTUREPROTECTION, INSULATION, AND UTILITIES AS NECESSARY FOR OBTAININGA CERTIFICATE OF OCCUPANCY REGARDLESS OF INFORMATION SHOWN INTHE CONSTRUCTION DOCUMENTS.
COORDINATION: THE CONTRACTOR IS RESPONSIBLE FOR THOROUGHLYREVIEWING THE CONSTRUCTION DOCUMENTS, INCLUDING THE SCOPE OFWORK AND ALL REQUIREMENTS NECESSARY TO COMPLETE THE WORK,FOR ALL TRADES AND SUPPLIERS. THE CONTRACTOR IS RESPONSIBLEFOR COORDINATING ALL CONSTRUCTION WORK AND SUBCONTRACTORS.
WORKMANSHIP: ALL WORK SHALL BE PERFORMED IN AN ORDINARY,CUSTOMARY, AND WORKMAN-LIKE MANNER AND IN STRICT ACCORDANCEWITH MANUFACTURER'S SPECIFICATIONS AND CUSTOMARY CONSTRUCTIONMETHODS.
SUBSTITUTIONS AND COLORS: WHERE NAME BRANDS AND/OR MODELNUMBERS ARE CALLED FOR IN THE SPECIFICATIONS, THEY ARE TO BEAS SPECIFIED OR AN APPROVED EQUAL AS DETERMINED BY THE OWNERAND ARCHITECT. WHERE COLORS OR TEXTURES ARE INDICATED,PROVIDE A MIN. 12"x12" SAMPLE PANEL FOR FINAL APPROVAL OFOWNER.
INSPECTION OF PREMISES: THE CONTRACTOR IS FULLY RESPONSIBLEFOR INSPECTING THE EXISTING PREMISES OR PROPERTY AND VERIFYINGALL EXISTING CONDITIONS IN THE FIELD, INCLUDING ALL DEEDRESTRICTIONS, EASEMENTS, UTILITIES, AND BUILDING REGULATIONS.
HOLD HARMLESS: ALL CONTRACTORS AND SUBCONTRACTORS AGREE TOHOLD HARMLESS AND INDEMNIFY THE OWNER, ARCHITECT, ENGINEER,AND DESIGNER FOR ANY AND ALL LIABILITIES, LOSSES, AND FOR CLAIMSWHICH MAY ARISE, DIRECTLY OR INDIRECTLY, ON ACCOUNT OF THECONSTRUCTION WORK, REGARDLESS OF THE CONTENT OF THECONSTRUCTION DOCUMENTS.
LICENSED TRADESMEN: TO THE EXTENT REQUIRED BY LAW, ALL WORKSHALL BE PERFORMED BY INDIVIDUALS DULY LICENSED AND AUTHORIZEDBY LAW TO PERFORM SAID WORK.
RELEASES: CONTRACTOR SHALL FURNISH OWNER EVIDENCE OFAPPROPRIATE RELEASES OR WAIVERS OF LIEN FROM SUBCONTRACTORSAND TRADESMEN FOR ALL WORK PERFORMED OR MATERIALS PROVIDEDPRIOR TO THE COMPLETION OF THE PROJECT.
CHANGE ORDER: ALL CHANGE ORDERS SHALL BE IN WRITING ANDSIGNED BY BOTH THE OWNER AND CONTRACTOR. NO ADDITIONALCHARGES WILL BE ALLOWED ON THE BASIS OF INFORMATION PROVIDEDOR NOT PROVIDED IN THE CONSTRUCTION DOCUMENTS.
INSURANCE: THE CONTRACTOR WARRANTS IT IS ADEQUATELY INSUREDFOR INJURY TO ITS EMPLOYEES AND OTHERS INCURRING LOSS ORINJURY AS A RESULT OF THE ACTS OF THE CONTRACTOR OR ITSEMPLOYEES OR SUBCONTRACTORS. THE CONTRACTOR ANDSUBCONTRACTOR SHALL HAVE IN FORCE THE MINIMUM LIMITS OFINSURANCE INCLUDING WORKMEN'S COMPENSATION, AS REQUIRED BYLAW, FOR THE DURATION OF THE PROJECT.
CLEANLINESS: CONTRACTOR AGREES TO REMOVE ALL DEBRIS ANDLEAVE THE PREMISES IN BROOM CLEAN CONDITION. CONTRACTORAGREES TO PROTECT ADJACENT PROPERTIES AND VEGETATION ANDOTHER EXISTING CONDITIONS TO BE PRESERVED FROM DAMAGE DUE TOCONSTRUCTION.
DISPUTES: ALL DISPUTES SHALL BE RESOLVED BY BINDINGARBITRATION IN ACCORDANCE WITH RULES OF THE AMERICANARBITRATION ASSOCIATION OR THROUGH MEDIATION BY A LICENSEDPROFESSIONAL MEDIATOR.
ACCURACY OF DOCUMENTS: THE OWNER AND CONTRACTOR RECOGNIZETHAT THERE MAY BE INACCURACIES OR OMISSIONS IN THECONSTRUCTION DOCUMENTS. NOTIFY THE OWNER AND ARCHITECTIMMEDIATELY OF ANY DISCREPANCIES OR OMISSIONS IN THECONSTRUCTION DOCUMENTS AND RESOLVE ANY PROBLEMS ARISINGIMMEDIATELY PRIOR TO CONTINUING THE WORK. THE ARCHITECT,DESIGNER, AND ENGINEER SHALL NOT BE HELD LEGALLY RESPONSIBLEFOR INACCURACIES OR OMISSIONS IN THE CONSTRUCTION DOCUMENTS.THE DESIGNER SHALL BE NOTIFIED BY THE CONTRACTOR OR OWNER INREGARD TO ANY AND ALL CHANGES OR REVISIONS MADE TO THECONSTRUCTION DOCUMENTS OR THE BUILDING IN THE FIELD DURINGCONSTRUCTION. THE ARCHITECT SHALL NOT BE HELD RESPONSIBLEFOR ANY COMPLICATIONS WHICH ARISE DUE TO CHANGES OR REVISIONSMADE TO THE CONSTRUCTION DOCUMENTS OR THE BUILDING IN THEFIELD WHICH OCCURRED WITHOUT PROPER NOTIFICATION.
PROVIDE ALL REQUIRED PLUMBING EQUIPMENT TO COMPLETE THEPROJECT, INCLUDING WATER, WASTE, AND VENT PIPES, CLEANOUTS,CHECK VALVES, AND FLOOR DRAINS, ETC.
PROVIDE ALL PLUMBING FIXTURES SELECTED BY OWNER TO COMPLETETHE PROJECT, INCLUDING WATER CLOSETS, BIDETS, LAVATORIES, SINKS,BATHTUBS, SHOWERS, FITTINGS, APPLIANCES AND EQUIPMENT.
INSTALL ALL PLUMBING AND GAS EQUIPMENT PER APPLICABLE CODESAND MANUF. SPECS.
VERIFY LOCATION OF ALL WATER AND SEWER LINES PRIOR TOFOUNDATION PLACEMENT.
WATER HEATER SHALL HAVE METAL DRIP PAN AND RELIEF LINE(SECONDARY DRAIN) FULL SIZE TO TERMINATION AT EXTERIOR WALL.
LAUNDRY FLOOR DRAIN SHALL TERMINATE AT SANITARY SEWER.
SECURE PIPING TO STRUCTURE WITH HANGERS AND STRAPS. PROVIDESHOCK ABSORBING AIR CHAMBERS AT EACH FITTING.
FIRE SPRINKLER SYSTEMS SHALL COMPLY WITH N.F.P.A. 13r. OBTAINALL REQURIRED PERMITS AND INSPECTIONS.
ENSURE HVAC SYSTEM IS DESIGNED TO PROVIDE ALL-WEATHER INSIDECOMFORT LEVELS IN ACCORDANCE WITH A.R.I. STANDARDS. HIGHEFFICIENCY 12.0+ SEER OR BETTER HVAC UNITS AND 80% A.F.U.E. ORBETTER SHALL BE INSTALLED.
SUMMER OUTSIDE TEMP. = 96 DEG. F INSIDE TEMP. =72 DEG. F WINTER OUTSIDE TEMP. = 20 DEG. F INSIDE TEMP. =75 DEG. F
PROVIDE ALL REQUIRED CONDENSING UNITS, DUCTWORK, RETURN ANDSUPPLY GRILLES, THERMOSTAT CONTROLS, CONDENSATE METAL PANSAND DRAINS, ELECTRICAL, ETC. TO COMPLETE THE PROJECT.
ALL DUCTWORK SHALL BE INSULATED RIGID METAL WITH SUPERIORQUALITY ADJUSTABLE PAINTED METAL SUPPLY GRILLES. INSULATEDFLEXIBLE DUCTWORK MAY BE USED FOR RETURN AIR SHAFTS AND INDIFFICULT TO ACCESS SUPPLY AREAS.
ALL SUPPLY GRILLES SHALL BE LOCATED IN A SYMMETRICAL LOGICALPATTERN WITH REGARD TO LIGHT FIXTURES, WINDOWS, DOORS, ANDROOM CEILING. MISPLACED GRILLES WILL BE RELOCATED AT NO COSTTO OWNER.
WOODEN LOUVER RETURN AIR GRILLE SHALL BE LOCATED 10" A.F.F.
ALL HVAC EQUIPMENT SHALL BE LOCATED TO PREVENT NOISE ANDVIBRATION IN ALL ROOMS OF BUILDING. HVAC FAN UNITS SHALL BEINSTALLED ON VIBRATION ISOLATORS. HVAC CONDENSING UNITS SHALLBE LOCATED ON CONCRETE PADS.
VERIFY LOCATION OF HVAC CONDENSING UNITS ON SITE PLAN PRIOR TOPLACING UNITS.
ALL MECHANICAL EXHAUSTS SHALL BE INSTALLED PER MANUF. SPECSAND TERMINATE AT THE EXTERIOR OF THE BUILDING.
DOWNDRAFT EXHAUST SHALL HAVE 8" PVC LINE AND BE INSTALLED PERMANUF. SPECS AT ISLAND OR WALL COUNTER.
PROVIDE EQUIPMENT ACCESS SPACE AND POSITIVE ATTIC VENTILATION,INCLUDING CONTINUOUS SOFFIT AND RIDGE VENTS.
PROVIDE ALL REQUIRED ELECTRICAL EQUIPMENT NECESSARY TOCOMPLETE THE PROJECT, INCLUDING SWITCHES, RECEPTACLES,CONDUITS, OUTLET AND JUNCTION BOXES, BREAKER PANELS, GFCIRECEPTACLES, ETC.
VERIFY THE PROPER PLACEMENT OF ALL ELECTRICAL EQUIPMENT,INCLUDING RECEPTACLE AND SWITCH HEIGHTS, AND CEILING FIXTUREOUTLET BOXES.NEAREST EXTERIOR WALL.
ALL SMOKE DETECTORS TO BE INTERCONNECTED WITH BATTERY BACKUP.
PROVIDE GFIC RECEPTACLES WHERE SHOWN OR AS REQUIRED BY CODE.PROVIDE WATER PROOF GFIC RECEPTACLES IN GARAGE AND ONEXTERIOR. (E) PROVIDE WATERPROOF GFIC DUPLEX RECEPTACLE INSOFFIT AT EVERY MAJOR CORNER OF THE ROOF (MINIMUM 4 REQUIRED)
PRE-WIRE AUDIO/VIDEO, COMMUNICATION, DATA AND SECURITY SYSTEMS.COORDINATE LOCATIONS WITH OWNER AND ARCHITECT.
PROVIDE FIRST QUALITY WINDOWS AND DOORS. ALL WINDOW SIZES ARENOMINAL. REFER TO MANUF. SPECS FOR ACTUAL SIZE. (B) MIN. NETCLEAR OPENING AT EGRESS WINDOWS SHALL BE 5.7 S.F. WITH SILL 36"A.F.F. MAX.
ALL HABITABLE ROOMS SHALL HAVE NATURAL LIGHT BY MEANS OFEXTERIOR GLAZED OPENINGS. GLAZED OPENING AREA TO BE MIN. 10%OF FLOOR AREA OF ROOM.
DOOR FROM GARAGE TO INTERIOR SHALL BE U.L. RATED 20 MINUTE 13/8" SOLID CORE SELF-CLOSING AND LATCHING WITH CLOSER.
ALL GLASS WITHIN 24" OF EGRESS DOORS OR 18" OF FLOOR SHALLBE SAFETY GLAZED. ALL FRENCH DOORS AND GLASS BATHENCLOSURES SHALL BE SAFETY GLAZED.
UNDERCUT DOOR OF LAUNDRY TO ALLOW ADEQUATE GAS APPLIANCEVENTILATION.
PROVIDE ALL NECESSARY HARDWARE TO COMPLETE THE PROJECT,INCLUDING HINGES, LOCKS, DEAD BOLTS, DOOR STOPS, DOOR PULLS,MASTER KEYS, ETC.
INTERIOR WALLS AND CEILINGS SHALL BE 1/2" GYPSUM BOARD ONFIRST AND SECOND FLOORS. WHERE CEILING HEIGHT EXCEEDS 10'-0",5/8" GYPSUM BOARD SHALL BE USED.
ON WALLS AND CEILINGS BELOW ALL STAIRS AND IN GARAGE USE 5/8"TYPE X FIRE-RATED GYPSUM BOARD.
INTERIOR WALLS AT TUB AND SHOWER ENCLOSURES SHALL BE 1/2"CEMENT BACKER BOARD.
ALL DRYWALL TO BE TAPED, FLOATED, AND SANDED TO PRESENT ASMOOTH SURFACE, FREE OF IRREGULARITIES AND IMPERFECTIONS.
PAINTED WALLS AND CEILINGS SHALL RECEIVE A LIGHT TEXTURE, ONECOAT PRIMER AND TWO FINISH COATS COATS OF HIGH QUALITY SATINLATEX PAINT IN COLORS SELECTED BY OWNER. CONTRACTOR TOVERIFY WITH OWNER TEXTURE TYPE DESIRED.
WALLS WITH COVERINGS SHALL RECEIVE NO TEXTURE OR PAINT. WALLCOVERING IS TO BE PROVIDED BY THE OWNER FOR INSTALLATION BYTHE CONTRACTOR.
PROVIDE ALL STONE, TILE, CARPET, WOOD, AND OTHER FLOOR FINISHMATERIALS NECESSARY TO COMPLETE THE PROJECT.
PROVIDE ALL KITCHEN, BATH, BAR, ETC. COUNTERTOP AND BACKSPLASHFINISH MATERIALS NECESSARY TO COMPLETE THE PROJECT.
TRANSITION FROM WOOD FLOOR TO ANY OTHER FLOOR MATERIAL SHALLHAVE A FLUSH 21/4" TRANSITION STRIP OF THE SAME MATERIAL ASTHE WOOD FLOOR.
PROVIDE ALL BATH ACCESSORIES SELECTED BY OWNER TO COMPLETETHE PROJECT, INCLUDING TOILET SEATS, TOILET PAPER HOLDERS,MIRRORS, SHOWER CURTAIN RODS, MEDICINE CABINETS, HEATERS,EXHAUST FANS, TOWEL BARS AND TOWEL RACKS.
ENSURE ADEQUATE HORIZONTAL AND VERTICAL CLEARANCES FOR THEINSTALLATION OF ALL EQUIPMENT AND APPLIANCES.
PROVIDE ALL NECESSARY EQUIPMENT AND APPLIANCES TO COMPLETETHE PROJECT. RESOLVE ANY ALLOWANCE ISSUES PRIOR TO BEGINNINGTHE PROJECT.
PROVIDE UTILITY CONNECTIONS IN RECESSED WALL BOXES FOR ALLAPPLIANCES AND EQUIPMENT REQUIRING WATER AND/OR GAS.
PROVIDE ALL REQUIRED ELECTRICAL AND PLUMBING FOR AN OUTDOORPOOL OR SPA.
COORDINATE ANY PERMITTING, LOCATION, AND INSTALLATION ISSUES WITHPOOL CONTRACTOR.
EXCEPT AS OTHERWISE INDICATED, PRE-MANUFACTURED FIREPLACESSHALL BE MAJESTIC SUPER HEARTH 36 OR APPROVED EQUALCONSTRUCTED WITH FIREBRICK, STONE HEARTH, STEEL DAMPER, SMOKECHAMBER, DOUBLE WALL FLUE, AND MASONRY CHIMNEY ACCORDING TOTHE LATEST AMI STANDARDS.
STEEL LINTEL SCHEDULE:
MAX OPEN'G ANGLE REQUIRED MIN BEAR'G
5'-0" 3 1/2 x 3 1/2 x 5/16 8" 7'-0" 4 1/2 x 3 1/2 x 5/16 8" 8'-0" 5 1/2 x 3 1/2 x 3/8 8" 9'-0" 5 1/2 x 3 1/2 x 3/8 9" 10'-0" 6 1/2 x 3 1/2 x 3/8 10"
ALL LONG LEGS VERTICAL
ALL FRAMING LUMBER SHALL BE #2 SYP-KD, EXCEPT THAT STUDS MAYBE STUD GRADE. ALL WALL FRAMING SHALL SPACE STUDS NO MORETHAN 16" o.c.
ALL TOP AND SOLE PLATES, HEADERS, AND SILLS SHALL BEWOLMANIZED PRESSURE TREATED #2 SYP
SECOND FLOOR FRAMING SHALL BE 18" WOOD TRUSSES U.N.O. PLACEDACCORDING TO ENGINEER DRAWINGS AND MANUF. INSTRUCTIONS.
SUB FLOOR MATERIAL OVER ANY SPANS SHALL BE 11/8" TONGUEAND GROOVE "STURDI-FLOOR", GLUED AND SCREWED TO FRAMING.
ROOF FRAMING SHALL BE 2X6 AND 2X8 #2 KD SYP RAFTERS PLACEDAT 16" O.C. ACCORDING TO ENGINEER DRAWINGS WITH 2X8 RIDGEBEAMS AND 2X10 VALLEY BEAMS. PROVIDE CONTINUOUS RIDGE VENTS.
EXTERIOR SHEATHING SHALL BE 1/2" CDX PLYWOOD WITH "TYVEK"BUILDING PAPER TAPED AND SEALED.
ROOF DECK SHALL BE 5/8" CDX PLYWOOD WITH "COOL-PLY" BACKING.REFER TO MANUF. SPECS. FOR HORIZONTAL SUPPORT APPLICATION ANDDETAILS.
SOFFIT SHALL BE 3/8" AC PLYWOOD WITH CONTINUOUS 3" OR 4"SOFFIT VENT.
ALL FRAMING DIMENSIONS ARE FROM FACE OF STUD OR TOCENTERLINES OF OPENINGS.
VERIFY LOCATION AND PLATE HEIGHT OF ALL DORMER, ATTIC, PONYWALL, TOWER, AND STORAGE ELEMENTS IN FIELD PRIOR TO PLACING.
ALL SECOND AND THIRD FLOOR BATHS AND LAUNDRY ROOM SHALLHAVE 1 1/8" RECESS TO ACCEPT TILE FLOORING. USE"STURDI-FLOOR" ON 2X4 LEDGER BETWEEN TRUSSES MIN.
CONTRACTOR SHALL VERIFY STAIR FRAMING PRIOR TO PLACEMENT. ALLSTAIR FRAMING SHALL BE PER APPLICABLE CODE. MIN. CLEAR HEADHEIGHT AT STAIRS SHALL BE 6'-10".
HAND RAIL AT INTERIOR STAIR SHALL BE 36" HIGH WITH MAX. 4"BETWEEN STILES. GUARD RAIL AT INTERIOR AND EXTERIOR BALCONYSHALL BE 42" HIGH WITH MAX. 4" BETWEEN STILES.
INTERIOR WOOD TRIM SHALL BE STAIN GRADE OR PAINT GRADE ASNOTED. ALL MILLWORK AND FINISHED CARPENTRY SHALL COMPLY WITHARCHITECTURAL WOODWORK QUALITY STANDARDS AS PUBLISHED BYARCHITECTURAL WOODWORK INSTITUTE (AWI) AND BE CUSTOM GRADE.
EXCEPT AS OTHERWISE SHOWN, PROVIDE DOOR AND WINDOW HEADERSPER THE FOLLOWING SCHEDULE:
MAX. SPAN SIZE 2'-6" 22x4 4'-6" 22x6 6'-0" 22x8 7'-6" 22x10
PROVIDE COMPREHENSIVE MOISTURE PROTECTION TO GUARANTEE WATERTIGHTNESS OF BUILDING, INCLUDING ROOF AND WALL ASSEMBLIES,CHIMNEYS, CHIMNEY CAPS, UNDER SLAB, WINDOWS, DOORS, AND OTHEROPENINGS. PROVIDE ALL MATERIALS NECESSARY FOR COMPREHENSIVEMOISTURE PROTECTION, INCLUDING FLASHING, COUNTER FLASHING,VAPOR BARRIERS, GUTTERS, DOWNSPOUTS, AND SEALERS.
ROOFING SHALL BE MIN. 30-YEAR RATED ASPHALT SHINGLES ON 30#ASPHALT FELT UNDERLAYMENT.
PROVIDE FIBERGLASS BATT THERMAL INSULATION IN ALL EXTERIORWALLS AND ABOVE ANY CEILINGS AT UNCONDITIONED SPACE.
FINISHED EXTERIOR WALL ASSEMBLY SHALL PROVIDE A THERMALINSULATION VALUE RATING OF NOT LESS THAN R-19.
FINISHED ROOF ASSEMBLY SHALL PROVIDE A THERMAL INSULATIONVALUE RATING OF NOT LESS THAN R-30.
VERIFY THAT THERMAL INSULATION DOES NOT BLOCK PROPERVENTILATION OF ROOF ASSEMBLY PRIOR TO INSTALLING ANY ROOFINGMATERIALS.
PROVIDE THERMAL INSULATION AT ALL HOT WATER PIPES. PROVIDETHERMAL INSULATION AT ALL WATER PIPES IN ATTIC, EXTERIOR WALLS,AND UNHEATED SPACES.
EXTERIOR SIDING AND TRIM BOARDS SHALL BE FIBER CEMENT LAPSIDING AND TRIM BOARDS AS MANUFACTURED BY JAMES HARDIEBUILDINGPRODUCTS.
G1.10
Thursday, April 22, 2010 1:21 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
182
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
SYMBOLS ANDABBREVIATIONS
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
C
1
EL. 11.25'
EL. 11.25'
+11'-4"
N
MATCH LINERE: A2.04
A
1
SS-1
CPT-1
PT-1
B-1
N
101
A8.12D1
C1
B1
A1
A1/A8.10
3
4
F
L
J
D Q
D Q
H
S
T
I
S
D Q
C
P
C
B
A
D
AA
B
C
D
B
C
D
E E
ABBREVIATIONS
H
J
L
B
A
C
E
D
I
G
F
M
O
P
Q
R
N
S
SYMBOLS
CAB. CABINETCB CATCH BASINCCTV CLOSED CIRCUIT TELEVISIONCEM. CEMENTCER. CERAMICCFMF COLD FORMED METAL FRAMINGCIP CAST IN PLACEC.I. CAST IRONCIR. CIRCLECJ CONTROL JOINTCKBD. CHALK BOARDCLG. CEILINGCLG. HT. CEILING HEIGHTCLR. CLEAR(ANCE)CL. CLOSETCM / cm CENTIMETERCMU CONCRETE MASONRY UNITCNTR. COUNTERCOL. COLUMNCOMPRES. COMPRESSIBLECOMP. COMPOSITIONCONC. CONCRETECOND. CONDITIONCONF. CONFERENCECONST. CONSTRUCTIONCONTR. CONTRACTORCONT. CONTINUOUSCORRU CORRUGATEDCORR. CORRIDORCG CORNER GUARDCSMT. CASEMENTCTR. CENTERCTSK COUNTERSUNKC.T. CERAMIC TILECU. FT. CUBIC FOOT (FEET)CU. YD. CUBIC YARDCW COLD/CHILLED WATERC-C CENTER TO CENTERC.O. CASED OPENINGC.W. COOL WHITEC.W.X. COOL WHITE DELUXE
JAN JANITORJST. JOISTJT. JOINT
AB ANCHOR BOLTABV. ABOVEACC. ACCESS / ACCESSIBLEACC. FL. ACCESS FLOORACC. PNL. ACCESS PANELACM ALUMINUM COMPOSITE METALACOUS. ACOUSTICALA.C.T. ACOUSTICAL CEILING TILEADJUST. ADJUSTABLEADJ. ADJACENTAD AREA DRAINA.F.F. ABOVE FINISH FLOORAGG. AGGREGATEALT. ALTERNATEALUM. ALUMINUMANCH. ANCHOR / ANCHORAGEANG. ANGLEANOD. ANODIZEDAPPROX. APPROXIMATEARCH. ARCHITECT / ARCHITECTURALAUTO. AUTOMATICAUX. AUXILIARYAVE. AVENUEAVG. AVERAGEA/C AIR CONDITIONINGA/V AUDIO VISUAL
BD. BOARDB/F BOTH FACESBITUM. BITUMINOUSBLDG. BUILDINGBLKG. BLOCKINGBLK. BLOCKBM BEAMB.M. BENCH MARKBOT. BOTTOMB.O.C. BOTTOM OF CURBBRG. BEARINGBRG. PL. BEARING PLATEBRKT. BRACKETB.S. BOTH SIDESBSMT. BASEMENTBTW. BETWEENB.U.R. BUILT-UP ROOFINGB.W. BOTH WAYSB&B BALLED AND BURLAPPEDB-B BACK TO BACK
I.D. INSIDE DIAMETERINCAND. INCANDESCENTINCL. INCLUDE(D)INFO. INFORMATIONINSUL. INSULATIONINT. INTERIORIN INCH(ES)I.P.S. INSIDE PIPE SIZE
EA. EACHEDF ELECTRIC DRINKING FOUNTAINEFOB EXTERIOR FACE OF BUILDINGEJ EXPANSION JOINTELAS. ELASTIC / ELASTOMERICELEC. ELECTRICALELEV ELEVATOREL. ELEVATIONEMER. EMERGENCYEP EXPLOSION PROOFEQUIP. EQUIPMENTEQ. EQUALESR ELASTIC SHEET ROOFINGE.W. EACH WAYEWC ELECTRIC WATER COOLEREWH ELECTRIC WATER HEATEREXH EXHAUSTEXIST. EXISTINGEXPAN. EXPANSIONEXP. EXPOSEDEXT. EXTERIOR
DBL. DOUBLEDEFL. DEFLECTIONDEPT. DEPARTMENTDF DRINKING FOUNTAIND.H. DOUBLE-HUNGDIAG. DIAGONALDIA. DIAMETERDIM. DIMENSIONDISC. DISCONNECTDISP. DISPENSERD.L. DEAD LOADDMPFG. DAMPPROOFINGDN DOWNDR. DOORDS DOWNSPOUTDTL. DETAILDWC. DRYWALL FURRING CHANNELDWG. DRAWINGDWR. DRAWERD. / d. DEEP / DEPTH
GALV. GALVANIZEDGAL. GALLONGA GAUGEGC GENERAL CONTRACTORGD. GUARDGEN. GENERALG.I. GALVANIZED IRONGL GLASS / GLAZINGGMP GUARANTEED MAXIMUM PRICEGR. GRADE / GRADINGGYP. GYPSUM
LAM. LAMINATEDLAV. LAVATORYLGTH. LENGTHLH LEFT-HANDLV. LEVELLIN. LINEARLL LIVE LOADLT. LIGHTLVR. LOUVERLWT LIGHT-WEIGHT
HB HOSE BIBBH.C. HOLLOW COREHDCP. HANDICAPPEDHDWD. HARDWOODHDWR. HARDWAREHD. HEADH.F.S. HALF FULL-SIZEH.M. HOLLOW METALHORIZ. HORIZONTALHP HORSEPOWERHR HOURHT. HEIGHTHVAC HEATING / VENTILATING /
AIR CONDITIONINGHW HOT WATERHYD. HYDRANT
M / m METERMM / mm MILLIMETERMACH. MACHINEMAINT. MAINTENANCEMAS. MASONRYMATL. MATERIALMAX. MAXIMUMMECH. MECHANICALMEP MECHANICAL / ELECTRICAL /
PLUMBINGMFR. MANUFACTURERMH MANHOLEMIN. MINIMUMMISC. MISCELLANEOUSM.L. METAL LATHMLDG. MOULDINGM.O. MASONRY OPENINGMTD. MOUNTEDMTG. MOUNTINGMTL. METALMULL. MULLION
OA OVERALLO.C. ON CENTERO.D. OUTSIDE DIAMETEROFCI OWNER FURNISHED /
CONTRACTOR INSTALLEDOFOI OWNER FURNISHED /
OWNER INSTALLEDOH OVERHEADO.P. OPERABLE PARTITIONOPH OPPOSITE HANDOPNG. OPENINGOPP. OPPOSITEOPQ. OPAQUEORD OVERFLOW ROOF DRAINO.S. OVERFLOW SCUPPEROSU OHIO STATE UNIVERSITYO/A OUTSIDE AIR
PART. PARTITIONPCF POUNDS PER CUBIC FOOTPCP PORTLAND CEMENT PLASTERPCT PORCELAIN CERAMIC TILEPED. PEDESTALPERF. PERFORATEDP.G. PLATE GLASSPL. PLATEPLAST. PLASTERPLAS. PLASTICPLF POUNDS PER LINEAR FOOTPLBG. PLUMBINGPLYWD. PLYWOODPNL. PANELPOL. POLISHEDPRKG. PARKINGPR. PAIRPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPTD. PAINTEDP.V.C. POLYVINYL CHLORIDEPVG. PAVINGPVMT. PAVEMENTP.L. PROPERTY LINEP.LAM. PLASTIC LAMINATEP/C PRECASTPFP PREFINISHED PANEL
QT QUARRY TILE
RCP REFLECTED CEILING PLANR.C.P. REINFORCED CONCRETE PIPERD ROOF DRAINREBAR REINFORCING BARRECEPT. RECEPTIONRECEP. RECEPTICLERECOM. RECOMMENDATIONREC. RECESSEDREF. REFRIGERATORREG. REGULATIONREINF. REINFORCEDREQ'D. REQUIREDRES. RESILIENTRET. RETURNREV. REVERSE / REVISIONRE REFER TORFG. ROOFINGRH RIGHT-HANDR RISERRM ROOMR.O. ROUGH OPENINGR.O.W. RIGHT OF WAYRAD. RADIUSR/AG RETURN AIR GRILLER/A RETURN AIR
FA FIRE ALARMF.C. FIRE CODEFD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFHC FIRE HOSE CABINETFH FIRE HYDRANTFIN. FINISH / FINISHEDFIXT. FIXTUREFLRG. FLOORINGFLR. FLOORFLSHG. FLASHINGFLUOR. FLUORESCENTF.P.W. FLOOD PROTECTION WALLFL FLOW LINEF.M. FACTORY MUTUALFND. FOUNDATIONFRPF. FIREPROOF(ING)FSEC FOOD SERVICE EQUIPMENT
CONTRACTORF.S. FULL SIZEFTG. FOOTINGFT. FOOT / FEETFURN. FURNISHFURR. FURRED / FURRINGF.V. FIELD VERIFYF.V.C. FIRE VALVE CABINETF.W.C. FABRIC WALL COVERING
NAT. NATURALNFHB NON-FREEZE HOSE BIBBN.I.C. NOT IN CONTRACTNOM. NOMINALNO. or # NUMBERN.R. NOISE REDUCTIONN.R.C. NOISE REDUCTION COEFFICIENTN.T.S. NOT TO SCALE
SCHED. SCHEDULES.C. SOLID CORESD STORM DRAINSECT. SECTIONSF SQUARE FOOT / FEETSH SINGLE-HUNGSHVL. SHELVES / SHELVINGSHTHG. SHEATHINGSHT. SHEETSHT. GL. SHEET GLASSSHWR. SHOWERSIM. SIMILARSPEC. SPECIFICATIONSPKR. SPEAKERSQ. SQUARES.S. STAINLESS STEELSS SANITARY SEWERSTAB, STABILIZE(D)STA. STATIONS.T.C. SOUND TRANSMISSION COEFFICIENTSTD. STANDARDSTL. STEELSTOR. STORAGESTRUCT. STRUCTURE / STRUCTURALSUSP. SUSPENDEDSW SWITCHSYM. SYMMETRICALSYN. SYNTHETICSYS. SYSTEMS/AD SUPPLY AIR DIFFUSERS/A SUPPLY AIR
CENTERLINE
@ AT
[ CHANNEL
ROUND/DIAMETER
PLATE
ANGLE
& AND
PER
SQUARE
PLUS OR MINUS
/
VAC. VACUUMV.C.T. VINYL COMPOSITION TILEVERT. VERTICALVEST. VESTIBULEV.W.C. VINYL WALL COVERING
UL UNDERWRITERS LABORATORYU.N.O. UNLESS NOTED OTHERWISEUofC UNIVERSITY OF CALIFORNIAUR. URINAL
T.B. TOWEL BARTCOC TEXTURE COATING ON CONCRETETEL. TELEPHONETEMP. TEMPERED / TEMPORARY /
TEMPERATURETHK. THICK(NESS)THRES. THRESHOLDTINT. TINTEDTKBD. TACKBOARDT.O.C. TOP OF CURB / CONCRETETOL. TOLERANCET.O.S. TOP OF STEEL / SLABT.O.S.S. TOP OF STRUCTURAL SLABT.O.W. TOP OF WALLT.P.D. TOILET PAPER DISPENSERTRANS. TRANSFERTRZO. TERRAZZOT TREADT&G TONGE & GROOVET.S. TUBE STEELT.T.C. TELEPHONE TERMINAL CABINETTV TELEVISIONTYP. TYPICAL
XFMR. TRANSFORMER
WC WATER CLOSETWDW. WINDOWWD. WOODWF WIDE FLANGEWH WALL-HUNGW.I. WROUGHT IRONWP. WATERPROOF(ING)WR. WATER RESISTENTWT. WEIGHTW.W.F. WELDED WIRE FABRICW.P. WORK POINTW.W. WARM WHITEW.W.X. WARM WHITE DELUXEW/ WITHW/I WITHINW/O WITHOUT
V
U
T
X
W
PL
MATERIAL REPRESENTATIONS
EXHAUST DIFFUSER
R/A GRILLE
S/A DIFFUSER
VERTICAL ELEVATION
SUSPENDED ACOUSTICAL
CEILING GRID
EXISTING FIXTURE TO REMAIN
REVISION NUMBER AND AFFECTED AREA
EXISTING FIXTURE TO BE REMOVED
RELOCATED FLUOR. LIGHT FIXTURE
NEW FLUOR. LIGHT FIXTURE
EXISTING ELEVATION
NEW ELEVATION
SURFACE-MTD. FLUOR. LIGHT FIXTURE
DIRECTIONAL SPOT (EYEBALL) LIGHT FIXTURE
FEATURE/CHANDLIER TYPE LIGHT FIXTURE
CEILING FAN
CEILING FAN W/ LIGHT KIT
SECURITY LIGHT FIXTURE
INTERIOR EXTERIOR
FIXTURE DESIGNATION (IF REQUIRED)
DIRECTIONAL (WALL-WASHER) FIXTURE
PENDANT LIGHT FIXTURE
WALL-MOUNTED (SCONCE) FIXTURE
RECESSED (CAN) LIGHT FIXTURE
UNDER CABINET LOW VOLTAGE FIXTURE
LOW VOLTAGE TREAD LIGHT
SURFACE-MTD. LIGHT FIXTURE
ELEVATIONSECTION
SPRAYED FIREPROOFING
BATT/BLANKET INSUL.
CONCRETE
RIGID INSUL.
ROOF DECK INSUL.
GYPSUM SHEATHING
PRECAST CONCRETE
GYPSUM WALLBOARD
JOINT FILLER
BACKER ROD & SEALANT
ACOUS. CEILING
CARPET
CMU
BRICK
CAST/CUT STONE
NATURAL STONE
FINISHED WOOD
METAL LATH & PLASTER
CERAMIC/QUARRY TILE
GLASS/MIRROR
STEEL
ALUMINUM
BRASS/BRONZE
GRADE/EARTH
GRAVEL
SAND
CONT. WOOD BLOCKING
DISCONT. WOOD SHIM
PLYWOOD (LOW & HIGH DETAIL)
ROOM NAME
BASE FINISH
ROOM / DOOR NUMBER
WALL SECTION / SECTION DETAIL
ENLARGED DETAIL
NORTH ARROW
ELEVATION (INTERIOR AND EXTERIOR)
BUILDING SECTION
NON-DIRECTIONAL SECTION DETAIL
PARTITION TYPE
ROOM IDENTIFICATION
(RE: PARTITION SCHEDULE FOR DESCRIPTION)
(RE: WINDOW SCHEDULE)
EQUIPMENT NOTE
ACCESSORY / PLAN / KEYED NOTE
(RE: DOOR SCHEDULE)
WINDOW / GLAZING TYPE
BREAK LINE
SHEET NUMBER
DETAIL NUMBER (LOCATION ON SHEET)
DETAIL REFERENCE
WALL FINISH
WALL/BASE FINISH NOTE
FLOOR/CEILING FINISH NOTE
101.1
5
WA.1
6
B42
ROOM / INTERIOR ELEVATIONS
SHEET LOCATION NUMBER
VIEW DIRECTION / ELEVATION NUMBER
MATCH LINE
COLUMN GRID INDENTIFICATION
ROOM NUMBER (AS REQ'D.)
MISCELLANEOUS FINISH NOTE
A5A5.21
A1A3.21
C1A4.14
C1A4.14
C1A4.14
C3A5.21
C1A2.41
SYMBOLS
INTERIOR ELEVATION
SHEET LOCATION NUMBER
ELEVATION NUMBER
B4
OR
IONIZATION DETECTOR
SPECIFIC MOUNTING HEIGHT (AS REQ'D.)
DUPLEX OUTLET
SWITCHED DUPLEX OUTLET
4 PLEX OUTLET
VOICE ONLY - SINGLE / DUPLEX / 4 PLEX
DATA ONLY - SINGLE / DUPLEX / 4 PLEX
VOICE AND DATA - DUPLEX AND 4 PLEX
SPECIAL PURPOSE OUTLET
220V OUTLET
(HATCHING INDICATES DIRECTION OF EGRESS)EXIT SIGN
SMOKE DETECTOR
FIRE ALARM HORN
SPEAKER
THERMOSTAT
SPRINKLER HEADS
SINGLE POLE LIGHT SWITCH
3-WAY LIGHT SWITCH
4-WAY LIGHT SWITCH
EXHAUST OR FAN SWITCH
EXHAUST OR LIGHT SWITCH
FLUSH FLOOR MTD. "J" BOX W/ DUPLEX OR4 PLEX OUTLET (COORDINATE EXACT LOCATIONW/ OWNER AND PROPOSED FURNITURE LAYOUT)
FLUSH FLOOR MTD. "J" BOX W/ VOICE AND/OR DATA(COORDINATE EXACT LOCATION W/ OWNER ANDPROPOSED FURNITURE LAYOUT)
CABLE PULL FOR FURNITURE
POWER POLE
"J" BOX FOR FUTURE/OTHER CONNECTION
EXHAUST FAN W/ LIGHT FIXTURE
EXHAUST FAN W/O LIGHT FIXTURE
A7.10
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1818
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Interior Elevations
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
4" 5 9/16" 2'-1 9/16" 2'-1 9/16" 2'-1 9/16" 5 5/8" 4"
8'-0"
3/4" STATUARY MARBLE
3/4" STATUARY MARBLE
2" WOOD TYP.
4" WOOD POST TYP.
SCALE: 1/2" = 1'-0"
C2Kitchen 0 1' 2' 4'
SCALE: 1/2" = 1'-0"
A2Kitchen 0 1' 2' 4'SCALE: 1/2" = 1'-0"
A3Kitchen Island 0 1' 2' 4'
SCALE: 1/2" = 1'-0"
C3Kitchen 0 1' 2' 4'
SCALE: 1/2" = 1'-0"
D3Kitchen Island 0 1' 2' 4'
A6.12
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1817
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Pier & Sill Details
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
8"
(TY
P.)
5"
NOTE:
ALL INFO NOT SHOWNSEE SECTION 6 FOR
1'-8
"
RE: PLAN
C
1'-0"2'-0"
6 MIL POLY
W=12"
D=2
4"
FLOOR
JOISTSRE: PLAN
RE: ARCH.
ELEV. 0'-0"
1-#4 CONT.MATCH STUD WIDTH
TYPICAL EXTERIOR GRADE BEAM
#3 VERT. x
W
D
RE
: PLA
N
7
RE: PLANSTRINGER
INFORMATION NOT SHOWNRE: SECTION 1 FOR ALL
ELEV. 0'-0"
SECTION:
CURB HEIGHT EXCEEDS 5"@ 18" O.C. PROVIDE WHERE
VAPOR BARRIER
W/ #3 STIR. @ 18" O.C.2-#5 TOP & BOTT. CONT.TYP. GRADE BEAM REINF.
2" SAND LAYER
DRILLED PIER & GRADE BM (TYP.)TYP. SLAB REINF.
#4 DWLS @ 16" O.C.
FLATWORKRE: ARCH
(TOP & BOTTOM)2-#5 CONT.
2'-0
"
11 1/4"
W
1/2"
D
RE
: PLA
N
8
FLOORRE: ARCH.
FLOOR JOISTS/ BEAMS
SOLID BLOCKING
SECTION:
ELEV. 0'-0"
TYPICAL GRADE BEAM @ GARAGE ENTRY
2'-0"
@ 18"
2'-0"
9
RE: PLAN
2 LAYERS OF2-2x8 (TREATED)
TIES#3 @ 18" O.C.
SECTION:
#3X 3'-0"
TO CONC. RE: ARCH. DWGSSTAIR STRINGER AND CONNECTION
TYPICAL GRADE BEAM @ STUDWALL CURB
HOLD-DOWN (PA18)@ EACH STRINGER
INFORMATION NOT SHOWNRE: SECTION 1 FOR ALL TYPICAL FOOTING @ EXTERIOR STAIR STRINGER DETAIL
C
RE: PLAN
FIRST FLOOR
BEAMRE: PLAN
WOOD COLUMN
C FOOTING & CMU PILASTER
STUD WALL
JOISTSRE: PLAN
RE: ARCH.FLOOR
(SIMPSON H6)HURRICANE STRAPS
@ EA. END OF BEAM
(W/ 8" MIN. EMBEDMENT)
PROVIDE 2 SIMPSONHOLD-DOWN (PA23)@ EVERY CMU PILASTER
STRINGERRE: PLAN
RE: SECTION 1 FOR ALLINFORMATION NOT SHOWN
EXTERIOR WALLFINISH. RE: ARCH.
HURRICANE STRAPS
FIRST FLOOR
@ EVERY OTHER STUD(SIMPSON LSTA 36)
(SIMPSON H6)
RE: PLANBEAM
HURRICANE STRAPS
@ EA. END OF BEAM
STUD WALL
RE: ARCH.FLOOR
FLOOR JOISTSRE: PLAN
(SIMPSON H4)HURRICANE STRAPS
@ EVERY OTHER JOIST
FOOTING & CMU PILASTERC
@ EVERY CMU PILASTERHOLD-DOWN (PA23)
SLEEPER x 1'-4"2-2x8 TREATED
16"x16" CMU PILASTER W/16"
(W/ 8" MIN. EMBEDMENT)
4- #5 X 1'-0"
16" O.C. FILL ALL CELL(SEE DETAIL "A")
LADDER TYPE JOINT REINF. @
@ EACH FOOTING
TOP & BOTTOM
CLEAN TOP OF
4- #5 EA. WAY
FOOTING THOROUGHLY (TYP.)3'-0"
PROVIDE 2 SIMPSON
RE: GENERAL NOTESEXTERIOR SHEATHING
SHEET S2.1 & S2.2
FIRST FLOOR
SOLID BLOCKING
RE: PLANSTRINGER
FINISHGRADE
1'-4
"4"
3"
1'-0
"
2'-0
"2'
-3"(
)
5 SECTION:
C
PORCH
FIRST FLOOR
EXTERIORSTUDS
FLOOR JOISTSRE: PLAN
RE: ARCH.FLOOR
FOOTING & CMU PILASTER
RE: PLAN
RE: PLANSTRINGER
FLOOR JOISTS
(W/ 8" MIN. EMBEDMENT)
PROVIDE 2 SIMPSONHOLD-DOWN (PA23)@ EVERY CMU PILASTER
2-2x12 TREATEDSLEEPER x 1'-0"
SLOPE
RIP TOPS OF 2x10JOISTS TO ACHIEVE
3 SECTION:
SOLID BLOCKING
FIRST FLOOR
WOOD COLUMNRE: PLAN
C
RE: PLANFLOOR JOISTS/ BEAMS
FLOORRE: ARCH.
FOOTING & CMU PILASTER
STRINGERRE: PLAN
HOLD-DOWN (PA23)@ EVERY CMU PILASTER(W/ 8" MIN. EMBEDMENT)
PROVIDE 2 SIMPSON
RE: PLANSTRINGER
C
TYPICAL EXTERIOR FOOTING
6 SECTION:
RE: SECTION 1 FOR ALLINFORMATION NOT SHOWN
4 SECTION:
INFORMATION NOT SHOWNRE: SECTION 1 FOR ALL
TYPICAL EXTERIOR FOOTING @ PORCH
SECTION:1
RE: SHEET S1.1 FOR CMUPILASTER DETAILS
FIRST FLOOR
SOLID BLOCKING
2 LAYERS OF2-2x8 (TREATED)
PROVIDE 2 SIMPSONHOLD-DOWN (PA23)
(W/ 8" MIN. EMBEDMENT)@ EVERY CMU PILASTER
SECTION:2
TYPICAL EXTERIOR FOOTING
TYPICAL INTERIOR FOOTING TYPICAL INTERIOR FOOTING @ PORCH
INTERIOR
FOOTING & CMU PILASTER
TYPICAL EXTERIOR FOOTING @ PORCH
FOOTING & CMU PILASTER
SCALE: 1/2" = 1'-0"
A4 Pier & Sill Details 0 1' 2' 4'
A6.11
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1816
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Sections & Specs
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
0'-0" FINISH FLOOR
LP 10'-0" PLATE HEIGHT
12'-0
"9'
-4 1
/2"
10'-0
"
TS 5"X5"X1/4"SHEAR SKELETON
TS 5"X5"X1/4"SHEAR SKELETON@ COLUMN
FIELD WELDTYPICAL
12" CONC.PIER
8"X8" HEAVYTIMBER
8X8X3/16 STEELPLATE AT COL.
1" DIA. ALL-THREAD
3/4" LAG BOLTAT 3'-0" CENTERS
H10A SIMPSON TIEAT WOOD RAFTERTYP.
ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE "ACI STANDARD BUILDING CODE
CONCRETE SHOULD BE PLACED IN THE FOOTING EXCAVATIONS AS SOON AS POSSIBLE BUTNO LATER THAN THREE HOURS AFTER EXCAVATION TO MINIMIZE THE POSSIBILITY OF
NORMAL WEIGHT CONCRETE (W = 145 PCF) WITH MINIMUM 28 DAY COMPRESSIVE STRENGTH
SEE ARCHITECTURAL DRAWINGS FOR FLOOR ELEVATIONS, SLOPES AND THE LOCATION OF
BARS - CONFORM TO ASTM A-615-GRADE 60, DOWELS AND STIRRUPS - GRADE 40.WELDED WIRE FABRIC - CONFORM TO ASTM A-185 OR A-409, FURNISHED IN FLAT SHEETSAND MUST BE SUPPORTED ON CHAIRS SPACED 4'-0" O.C. MAXIMUM EACH WAY.
1 1/2" TOP, 3" BOTTOM, 2" SIDES (3" SIDES IF EARTH FORMED)
CLEAN TOPS OF PIERS AND BOTTOM OF GRADE BEAM TRENCHES THOROUGHLY PRIOR TO
GRADE BEAM BOTTOM REINFORCEMENT SHALL BE SUPPORTED ON CHAIRS @ 6'-0" MAXIMUMSLAB REINFORCEMENT SHALL BE SUPPORTED ON CHAIRS, @ A 4'-0" MAXIMUM SQUARE GRID.
LEAST 95% OF STANDARD PROCTOR (ASTM D698 MAXIMUM DRY DENSITY AT OR 2
TESTING: ALL COMPACTED FILL SHALL BE TESTED BY A CERTIFIED TESTING AGENCY AT THE
AND 2" LEVELLING SAND. (NOTE THAT EXISTING GRADE MAY HAVE TO BE CUT TO ACHIEVE THEPROVIDE 1-8" LOOSE LIFTS OF COMPACTED FILL (TOTAL COMPACTED FILL THICKNESS = 6")
DIRECTED AWAY FROM THE FOUNDATION SOILS. (USE A MINIMUM SLOPE OF 5% WITHIN 10 FEET
BUILDER SHALL ADVISE THE OWNER OF THE SITE DRAINAGE REQUIREMENTS.STRUCTURE DURING OR AFTER COMPLETION OF THE CONSTRUCTION & THE LANDSCAPING. THEOF THE FOUNDATION). NO PONDING OF SURFACE WATER SHALL BE ALLOWED NEAR THE
IT IS RECOMMENDED THAT SITE DRAINAGE BE WELL DEVELOPED. SURFACE WATER SHOULD BE
RATE OF ONE TEST PER 1,000 SQUARE FEET OF EACH LIFT.
COMPACTED FILL DEPTH SPECIFIED HEREIN.)
PERCENTAGE POINTS ABOVE THE OPTIMUM MOISTURE CONTENT.
SITE DRAINAGE:
7.
6.
SLABS ON GRADEGRADE BEAMS
DETAILING - CONFORM TO ACI DETAILING MANUAL, 315-80.
LAP CONTINUOUS REINFORCING STEEL 36 BAR DIAMETERS.
REINFORCING STEEL COVERAGE:
4.
SPACING.6.5.
WALLS
FOOTINGS
3.
3" BOTTOM AND SIDES
1 1/2"1 1/4" TOP
LIQUID LIMIT: 28 TO 40 %FILL SHALL BE PLACED IN MAXIMUM LOOSE LIFTS OF 8 INCHES AND COMPACTED TO AT
STRIP AREAS WITHIN BUILDING LINES TO REMOVE ALL VEGETATION, TOP SOIL AND DEBRIS.
AREAS. SUCH ZONES SHALL BE REMOVED AND REPLACED WITH SELECT FILL.FOLLOWING STRIPPING, PROOF ROLL EXPOSED SUBGRADE TO IDENTIFY WEAK OR SOFT
GRADE AREA TO PREVENT PONDING OF WATER. DO NOT ALLOW EXPOSED SUBGRADE TO DRY.
CONTRACTOR SHALL REVIEW & BECOME THOROUGHLY FAMILIAR W/ THE CONTENTS OF
CONSTRUCTION DOCUMENTS. ANY PROBLEMS ARISING FROM THE CONTRACTOR'S LACK OFFAMILIARITY WITH SOILS REPORT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
REFERENCED SOILS REPORT, WHICH WILL BE CONSIDERED AN INTEGRAL PART OF THE
CONTRACTOR SHALL SHALL VERIFY ALL DIMENSIONS & ELEVATIONS
PLASTICITY INDEX (PI) : 7 TO 20 %
W/ ARCHITECTURAL DRAWING BEFORE FABRICATION.
CLEAN SANDY CLAY, FREE OF ORGANIC MATTERALL FILL SHALL BE SELECT MATERIALS FOLLOWS:
SUBGRADE PREPARATION AND FILL:2.
5.
4.3.
1.
2.
1.
2.(f'c) = 3000 PSI.
FLOOR DEPRESSIONS.
REINFORCING STEEL:
CAVING OF DRILLED EXCAVATION WALLS.
PLACEMENT OF CONCRETE IN THE GRADE BEAMS.5.
1.2.
4.
3.
REQUIREMENT FOR STRUCTURAL CONCRETE: (ACI 318-99)".
CONCRETE:1.
SUCH OPENINGS SHALL BE APPROXIMATELY EQUALLY DISTRIBUTED ALONG THE LENGTHOF AT LEAST TWO OPPOSITE SIDES. THEY SHALL BE COVERED WITH CORROSIONRESISTANT WIRE MESH WITH MESH OPENINGS OF r INCH IN DIMENSION.
INSULATION: PROVIDE COTTON BATTS SPRAY INSULATION UNDER CRAWL SPACE.4.
CRAWL SPACE NOTES
WITHIN UNDERFLOOR AREAS.
NATURALLY DURABLE SPECIES AS LISTED IN IBC 2000.
UNDERFLOOR CLEARANCE: WOOD JOISTS OR THE BOTTOM OF WOOD FLOORS CLOSERTHAN 18 INCHES OR WOOD GIRDERS CLOSER THAN 12 INCHES TO THE GROUND UNDERFLOORAREAS AND THEIR SUPPORTS, SHALL BE TREATED WOOD OR ALL HEARTWOOD OF APPROVED
ALL UNDER-FLOOR ACCESS OPENINGS SHALL BE EFFECTIVELY SCREENED OR COVERED. PIPES,
FOUNDATION VENTILATION: UNDERFLOOR AREAS SHALL BE VENTILATED BY AN APPROVED
DUCTS AND OTHER CONSTRUCTION SHALL NOT INTERFERE WITH THE ACCESSIBILITY TO OR
BY 24-INCH ACCESS OPENING UNOBSTRUCTED BY PIPES, DUCTS AND SIMILAR CONSTRUCTION.ACCESS: ACCESSIBLE UNDERFLOOR AREAS SHALL BE PROVIDED WITH A MINIMUM 18-INCH
SHALL HAVE A NET AREA OF NOT LESS THAN 1 SQUARE FOOT FOR EACH 150 SQUARE
PRACTICAL AND SHALL PROVIDE CROSS VENTILATION. THE REQUIRED AREA OFFEET OF UNDER-FLOOR AREA. OPENINGS SHALL BE LOCATED AS CLOSE TO CORNERS AS
MECHANICAL MEANS OR BY OPENINGS IN EXTERIOR FOUNDATION WALLS. SUCH OPENINGS3.
1.
2.
GENERAL NOTES FOR FOUNDATION SYSTEM
PROJECT NO:
08018
Sheet 10 OF 11
S1.1
arc
hitectu
re:k
elle
r_arc
hitectu
re:0
8018_m
f_ham
pto
n:C
onstr
uction_D
ocum
ents
:08018_H
am
pto
n_P
RJ_05.p
ln Matt Ford
22
31
Du
nst
an
Rd
Ho
ust
on
, T
ex
as
#P
ost
Structural Details
86081
ITECT
SA
AREDR
EGIS
R
TE
TEOFTA
TS
E X
CH
RELL
EKR.LE
HCIM
A
copyrighted documentc
So
uth
Ham
pto
n
ISS
UE
D F
OR
PE
RM
IT 2
1S
T A
UG
US
T 2
00
8
5'-3" 6'-9 1/2" 4'-9 1/4"
7'-0"
7'-0"
7'-0"
19'-1"
19'-9 1
/4"
EXISTING RAISED FLOORINGTO REMAIN
12/36 PIERS TYP.
EXISTING SLAB TO REMAIN12/36 PIERS TYP.
6"
14"
@ 24" INTO EXISTING GRADE BEAM
DRILL & EPOXY #4 DLWS.
EMBEDMENT4"
EXISTING SLAB
NOTE
SEE PLAN FOR SLAB
& #3 STIRR @ 12" O.C.
3-#5 TOP & BOTT. CONT
BEAM REINF.
2'-0"
1'-0"
1'-0"
2'-0"
(MAT
CH
EX
ISTI
NG
- 2'
-0"
MIN
)
(MAT
CH
EX
ISTI
NG
- 2'
-0"
MIN
)
FIN FLR
FIN FLR
13/4"=1'-0"
23/4"=1'-0"
33/4"=1'-0"
..................
..................
..................
..................
..................
20 PSF
100 PSF
40 PSF
100 PSF
60 PSF
BUILDING CODE.
GENERAL
3. THE DESIGN DEAD LOADS ARE AS SHOWN ON TRUSS LOADING SCHEDULE
THE CODE RECOMMENDED LIVE LOADS ARE AS FOLLOWS:
MPH 3 SECOND GUST WIND SPEED AS SPECIFIED IN THE ABOVE REFERENCED CODE.
2. THE STRUCTURE HAS BEEN DESIGNED TO WITHSTAND THE WIND PRESSURES FOR 110
1. THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2000 INTERNATIONAL
(F'c) OF 3000 PSI.
CONCRETE
1. ALL CONCRETE SHALL HAVE NATURAL SAND FINE AGGREGATE AND NORMAL
WEIGHT COARSE AGGREGATES CONFORMING TO ASTM C33, TYPE I PORTLAND
CEMENT CONFORMING TO ASTM C150, AND A 28 DAY COMPRESSIVE STRENGTH
RESIDENTIAL BALCONIES
CORRIDORS
RESIDENTIAL FLOOR
STAIRS
ROOF
DESIGN CRITERIA
ALLOWABLE SOIL BEARING PRESSURES:
TOTAL LOADS ............. 2,500 PSF
1. THE SUBSURFACE INFORMATION AND FOUNDATION DESIGN ARE BASED ON AN ASSUMPTION
OF SOIL IN THE GENERAL AREA.
2. THE FOUNDATION FOR THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING
FOUNDATION
BEARING DEPTH ......... 2'-0" BELOW EXISTING GRADE
SE
E P
LAN
FIN FLR
1'-0"
NOTE
SEE PLAN FOR SLAB
2'-0"
(MAT
CH
EX
ISTI
NG
- 2'
-0"
MIN
)
43/4"=1'-0"
1'-0"
2'-0"
NOTE
SEE PLAN FOR SLAB
#3 STIRRUPS AT 6"
#3 STIRRUPS AT 12"
T.O. SLAB
VERTICAL
REINFORCING
HOOP TIES
3" C
LR.
7 1/
2"7
1/2"
7 1/
2"
INCREASE SHAFT DIAMETER
IF SLOUGHING OCCURS
SH
AFT
DIA
4 #5 VERTICAL
CONTINIUOUS 12/36
1'-3
"
45 MAX.
36" UNDERREAM DIAMETER
SE
E F
OU
ND
ATIO
N N
OTE
S F
OR
FO
UN
DTI
ON
DE
PTH
BE
LOW
EX
ISTI
NG
GR
AD
E
3/4"=1'-0"5
48" UNDERREAM DIAMETER
6 #5 VERTICAL
CONTINIUOUS 16/48
A
S
GIN
EE
R
OF T ETA
T E
S
ST ERR
EGE I
76596
ASSION L E
PR
O
FED
N
X
HISHAM N. EL-CHAAR
SCALE: 1/4" = 1'-0"
1 Pier layout 0 2' 4' 8'
1"
5 1/2"
1"
11"
SCALE: 1/4" = 1'-0"
A2Drilled Pier Detail 0 2' 4' 8'
SCALE: 1' = 1'-0"
B3Drilled Pier Detail 0 1/2'' 1'' 2''
SCALE: 1 1/2"= 1'-0"
C1 Base Plate Detail 0 6'' 12'' 18''
A6.10
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1815
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Foundation Plan
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
B
C
D
A
1 2
(2) 2" x 12" SILL
2" x 12" joist @16 O.C.
12x36 12' DEEPPIERS CENTEREDAT EACHFOOTING
2" x 12" joist @16 O.C.
2" x 12" joist @16 O.C.
2" x 12" joist @16 O.C.
2" x 12" joist @16 O.C.
2" x8" joist @16 O.C.
2" x
8" jo
ist @
16 O
.C.
12x36 12' DEEPPIERS CENTEREDAT EACH TS COL.
12x36 12' DEEPPIERS CENTEREDAT EACH TS COL.
10'-2 9/16" 10'-0" 9'-8 13/16" 13'-2 3/8"
10'-3
11/
16"
8'-0
"8'
-0"
8'-0
"16
'-0"
5'-2
"7'
-7 1
3/16
"9'
-6 1
/2"
8'-7
5/1
6"6'
-6 1
3/16
"
11'-9
"11
'-9 3
/16"
11'-9
3/1
6"11
'-3 1
/8"
19'-5 11/16"
12'-5 1/4" 10'-10 1/2" 10'-5 1/4"
26'-0
"
B5A4.12
A4A4.11
A4A4.11
A5A3.12
A4A3.11
A2A6.11
A2A6.11
C4A4.11
C4A4.11
B
C
D
A
1 2
DW
F
6
7
8
9
10
1
2
3
4
Cus
tom
Tex
t 1C
usto
m T
ext 2
UP
1
2
3
4
Cus
tom
Tex
t 1C
usto
m T
ext 2
UP
1234
Custom Text 1Custom Text 2 U
P
2" x 12" joist @16 O.C.
2" x8" joist @16 O.C.
2" x
8" jo
ist @
16 O
.C.
(2) 2X12
(2) 2
X12
(2) 2X12
7.5"
X11
.5" P
LAM
2" x8" joist @16 O.C.
2" x8" joist @16 O.C.
7.5"
X11
.5" P
LAM
11'-9
"11
'-9"
11'-9
"
11'-7
1/8
"
8'-0"
26'-0
"TS 5" X1/4"
SLO
PE
2" x
8" jo
ist @
16 O
.C.
2" x
8" jo
ist @
16 O
.C.
2" x
8" jo
ist @
16 O
.C.
2" x
8" jo
ist @
16 O
.C.
2" x
8" jo
ist @
16 O
.C.
2" x
8" jo
ist @
16 O
.C.
DESIGNATES SHEAR WALL TYPE. RE: SCHEDULE, NOTES,
DESIGNATE COL. FROM FLR. ABOVE (STEEL OR WOOD PER NOTE 9)
RE: SHEET S2.2 FOR ALL FRAMING NOTES, DETAILS, & SCHEDULES.15.
13.
14.
11.
12.
A. SUPPORTED ON A BEAM @ THIS LEVEL.B. CONTINUED TO SLAB BELOW. (MATCH SIZES)
DESIGNATES SHEAR WALL HOLD-DOWN ANCHOR.
AND DETAILS ON SHEET S2.1.
ALL COLUMNS FROM FLOOR ABOVE MUST BE EITHER:
DESIGNATES BEAM HANGER. IF NOT IDENTIFIED ON PLAN,
9.
10.
7.
8.
5.
6.
3.
4.
USE TYPICAL HANGERS SPECIFIED IN GENERAL NOTES.
DESIGNATE STEEL & WOOD COLUMNS.
DESIGNATE PLYWOOD DECKING
DESIGNATE FURR-DOWN CEILING.
DESIGNATES SHEAR WALL.
ALL BEAMS & HEADERS SHALL BE 2-2x12 (U.O.N.)
ALL BEAMS & HEADERS SHALL BE #2 S.Y.P. (U.O.N.)
LARGER THAN 24" SQUARE (TYP. U.O.N.)PROVIDE DOUBLE FRAMING @ CEILING OPENINGS
PLAN NOTES
2.
1.
ALL JOISTS SHALL BE #2 S.Y.P. (U.O.N.)
ALL JOISTS ARE 2X12 @ 16" O.C. (U.O.N.)
RE: GENERAL NOTES FOR OTHER REQUIREMENTS.RE. ARCH. DWG'S FOR ROOF SLOPES & OTHER DATA NOT CONTAINED HEREIN.RE. SHEETS S2.2 FOR FRAMING GENERAL NOTES, TYP. DETAILS & SCHEDULES.
ROOF DECKING TO BE 1/2" C.D.X. WITH PANEL SPAN RATING OF 24-0.PROVIDE DOUBLE RAFTERS UNDER ALL DORMER WALLS (U.O.N.).
8.9.
6.7.
BM BRACE TO BEAM
ROOF FRAMING IS DESIGNED FOR COMPOSITION SHINGLE ROOF @ 3.5 PSF.
ALL RAFTERS ARE 2x6 #3 S.Y.P. AT 19.2" O.C. U.O.N.
B. SHALL MATCH OR EXCEED THE CUT END OF THE RAFTER. INTO IT (EXAMPLE: 2x8 BEAM FOR 2x6 RAFTER);
DEPTH OF RIDGE BEAM, HIP OR VALLEY RAFTER:
PARALLEL, RAFTER TIES SHALL BE SPACED NOT MORE THAN 48" O.C.BETWEEN EXTERIOR WALLS WHEN SUCH JOISTS ARE PARALLEL TO THE RAFTERS. WHERE NOTRAFTERS SHALL BE NAILED TO ADJACENT CEILING JOISTS TO FORM A CONTINUOUS TIE
A. SHALL BE ONE SIZE WIDER THAN THE LARGEST RAFTER FRAMING
PROVIDE 2x6 COLLAR TIES AT 48" O.C. AT UPPER 1/3 OF ROOF.
PROVIDE DOUBLE FRAMING @ EDGES OF ALL ROOF OPENINGS LARGER THAN 24".
3.
5.
4.
2.1.
BRACE TO DOUBLE JOIST(ONE SIZE LARGER THAN CLG JOIST)
BRACE TO STRONGBACK
PLAN NOTES
BJBS
VALLEY3 RIDGE
1 HIP2
2x6 CONTINUOUS PURLINROOF BREAK
45
ROOF BRACING LEGEND
BRACE SUPPORT DESIGNATION:(ALL BRACING TO WALLS UNLESS OTHERWISE NOTED)
INDICATES A VERTICAL (OR NEARLY VERTICAL)BRACE TO SUPPORTING MEMBER BELOW
DESIGNATES BRACE (APPROXIMATELY IN THE INDICATED DIRECTION)
3.
2.
1.
SCALE: 3/16" = 1'-0"
A3 Foundation Plan 0 4' 8' 12'SCALE: 1/8" = 1'-0"
A4 Attic Plan 0 4' 8' 16'SCALE: 1/8" = 1'-0"
A5 Roof 0 4' 8' 16'
A5.10
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1814
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Green Technology
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
2
4
2
4
2
4
HARDI PLANK SIDING2X2 FURRING STRIPS AT 16" O.C.
1/2" TECHSHIELDR-13 BATT INSULATION2X4 STUDS 16" O.C.1/2" GYP BD. AT INTERIOR
30 YR ASPHALT SHINGLES
1/2" CDX PLYWOOD SHEATHING
2X6 RAFTERS AT 16" O.C.
6
2
6
22
6
PERFORATED RADIANT BARRIERLEAVE SLACK IN BARRIER ASSHOWN TO GIVE 3" AIRSPACE
15lb BLACK FELT PAPER
2 2 2 2 2 2
1/8" SCREEN AT BASE OF WALL
1/2" OSB
2 4
42
6
2
6
2
42
442
2
CONTINUOUS INSULATIONBAFFLE
POLYCELL INSULATIONBARRIER AT ALL EXTERIORSTUD WALLS TYP.
R-30 BLOWN INSULATIONIN ATTIC
1'-0" MIN.
1/2" PLYWOOD SHEATING
PERFORATED RADIANTBARRIER
2/A7
2X2 FURRING STRIPS
PERFORATED RADIANTBARRIER OVER 15lbFELT PAPER OVER1/4" MASONITESHEATHING
RE: WATERPROOFINGSHEET A.8 FORWINDOW WRAP DETAILS
1/A7
1/2" OSB SHEATHING
1X4 TRIM
6" HARDI PLANK SIDING
12" MESH SCREENWITH 1/2" STAPLES
2x6 SYP FLOORING
2
12
2
12
2
12
WRAP SCREEN AT BOTTOMOF AIR SPACE
RE: 1/A10 FORSTRUCTURAL
FINISH FLOOR
2
12
R19 SPRAY FOAM INSUL.
1/2" CDX AT BOT. OF JOIST
AMERICAN STANDARDFREEDOM 95 FURNACE
AMERICAN STANDARDACCUCLEAN SYSTEM
AMERICAN STANDARDACCUEXCHANGE ERV
DUCTSPRINGHOUSEWATER SYSTEM
LOW
VO
LT. P
AN
EL
(QHUJ\(IFLHQF\
&DYLW\:DOO'HVLJQ 7DQNOHVVZDWHUKHDWHU 6RODUSDQHOVWLHGWRJULG 5DGLDQW%DUULHU+RXVH:UDS 3DVVLYH6RODU'HVLJQVLWHSODFHPHQW +LJK(IFLHQF\+9$&V\VWHP 5HHFWLYHURRQJIRUPLQLPL]LQJKHDWJDLQ ([SDQGLQJIRDPLQVXODWLRQ
+HDOWK\+RPH(QYLURQPHQW 1R92&SDLQWIRULQWHULRUV (59HQHUJ\UHFRYHU\YHQWLODWRU)UHVK$LU6XSSO\ 1R92&ZRRGRRUQLVK $PHULFDQ&OD\ZDOODQGFHLOLQJQLVK $LUOWUDWLRQ6\VWHP
:DWHU0DQDJHPHQW PLQLPDOIRRWSULQWRISHUYLRXVDUHD /RZ)ORZVLQNDQGVKRZHU LQGLJHQRXVODQGVFDSHUHTXLULQJQRLUULJDWLRQ 5DLQZDWHUKDUYHVWLQJ
5HSXUSRVH5HF\FOH &RQFUHWHFRQWDLQV\DVK /RFDODJJUHJDWHLQFRQFUHWH /RFDOO\UHFODLPHG6KLSODSVLGLQJRQ(OHYDWLRQ /RFDOO\UHF\FOHG:RRG)ORRULQJ 5HSXUSRVHGZRRGHQZLQHEDUUHOVIRUUDLQZDWHUVWRUDJH
)UHVK$LU,QWDNH+HDW([FKDQJHU
5HFODLPHG6KLSODS6LGLQJ
([SDQGLQJ)RDP,QVXODWLRQ
5DGLDQW%DUULHU:DOO
Construction Photos from Y house
3,,+WSH[PU\T targeted
*ULG7LH,QYHUWHU
0HFKDQLFDO6\VWHPV
5HSXSRVHG
6HDODQWVDGKHVLYHV'HWDLOV
(QYHORSH'HWDLOV
3OXPELQJV\VWHPV
)RRG&RRNLQJV\VWHPV
.LWFKHQFRPSRVWHU
housing categories
'XDO)OXVK7RLLHWVW
6RODU3DQHO
Professionals Corner
R-Value TableInsulation Values For Selected Materials
Use the R-value table below to help you determine the R-value of your wall or ceilingassemblies. To obtain a wall or ceiling assembly R-value you must add the r-values ofthe individual components together. See the following example:
Calculating Assembly Wall R-Value*Formula: Assembly R-value = 1 / (Assembly U-value) = 1 / (U-studs x % + U-cavity x %)
ComponentR-ValueStuds
R-ValueCavity
AssemblyR-Value
Wall - Outside Air Film 0.17 0.17 Siding - Wood Bevel 0.80 0.80 Plywood Sheathing - 1/2" 0.63 0.63 3 1/2" Fiberglass Batt 11.00 3 1/2" Stud 4.38 1/2" Drywall 0.45 0.45 Inside Air Film 0.68 0.68 Percent for 16" o.c. + Additional studs 15% 85% Total Wall Component R-Values 7.12 13.73 Wall Component U-Values 0.1404 0.0728 Total Wall Assembly R-Value 12.05* This example is just for wood frame construction. Steel studs are a more complicated calculation.
R-Value Table
MaterialR/Inch
R/Thickness
Insulation MaterialsFiberglass Batt 3.14-4.30 Fiberglass Blown (attic) 2.20-4.30 Fiberglass Blown (wall) 3.70-4.30 Rock Wool Batt 3.14-4.00 Rock Wool Blown (attic) 3.10-4.00 Rock Wool Blown (wall) 3.10-4.00 Cellulose Blown (attic) 3.13 Cellulose Blown (wall) 3.70 Vermiculite 2.13
Autoclaved Aerated Concrete 1.05
Urea Terpolymer Foam 4.48 Rigid Fiberglass (> 4lb/ft3) 4.00
Radiant BarrierCoatingLO/MIT AtticCoolingTechnologyResidential &CommercialInsulationwww.SOLEC.org
Spray FoamInsulationSave Up To 40%On Energy Bills.Same-DayIn-House Quote.Houston.www.TexasHomeInsulation.com
InsulationEstimatesFoam, Blown,Sound, Reflective,Etc Get FreeEstimates Today!www.ServiceMagic.com
Spray FoamInsulation KitDIY Spray FoamInsulation Kits..Insulate & SaveYour EnergyDollarswww.foampower.com
ColoradoENERGY.org - R-Value Table http://www.coloradoenergy.org/procorner/stuff/r-values.htm
1 of 4 10/16/09 5:20 PM
Expanded Polystyrene (beadboard) 4.00 Extruded Polystyrene 5.00 Polyurethane (foamed-in-place) 6.25 Polyisocyanurate (foil-faced) 7.20 Construction MaterialsConcrete Block 4" 0.80Concrete Block 8" 1.11Concrete Block 12" 1.28Brick 4" common 0.80Brick 4" face 0.44Poured Concrete 0.08 Soft Wood Lumber 1.25 2" nominal (1 1/2") 1.88 2x4 (3 1/2") 4.38 2x6 (5 1/2") 6.88Cedar Logs and Lumber 1.33 Sheathing MaterialsPlywood 1.25 1/4" 0.31 3/8" 0.47 1/2" 0.63 5/8" 0.77 3/4" 0.94Fiberboard 2.64 1/2" 1.32 25/32" 2.06Fiberglass (3/4") 3.00 (1") 4.00 (1 1/2") 6.00Extruded Polystyrene (3/4") 3.75 (1") 5.00 (1 1/2") 7.50Foil-faced Polyisocyanurate (3/4")
5.40
(1") 7.20 (1 1/2") 10.80Siding MaterialsHardboard (1/2") 0.34Plywood (5/8") 0.77 (3/4") 0.93Wood Bevel Lapped 0.80
ColoradoENERGY.org - R-Value Table http://www.coloradoenergy.org/procorner/stuff/r-values.htm
2 of 4 10/16/09 5:20 PM
Aluminum, Steel, Vinyl (hollow backed)
0.61
(w/ 1/2" Insulating board) 1.80Brick 4" 0.44
Interior Finish MaterialsGypsum Board (drywall 1/2") 0.45 (5/8") 0.56Paneling (3/8") 0.47Flooring MaterialsPlywood 1.25 (3/4") 0.93Particle Board (underlayment) 1.31 (5/8") 0.82Hardwood Flooring 0.91 (3/4") 0.68Tile, Linoleum 0.05Carpet (fibrous pad) 2.08 (rubber pad) 1.23Roofing MaterialsAsphalt Shingles 0.44Wood Shingles 0.97WindowsSingle Glass 0.91 w/storm 2.00Double insulating glass (3/16") air space
1.61
(1/4" air space) 1.69 (1/2" air space) 2.04 (3/4" air space) 2.38 (1/2" w/ Low-E 0.20) 3.13 (w/ suspended film) 2.77 (w/ 2 suspended films) 3.85 (w/ suspended film and low-E) 4.05Triple insulating glass (1/4" air spaces)
2.56
(1/2" air spaces) 3.23Addition for tight fitting drapes or shades, or closed blinds 0.29DoorsWood Hollow Core Flush (1 3/4")
2.17
Solid Core Flush (1 3/4") 3.03 Solid Core Flush (2 1/4") 3.70
ColoradoENERGY.org - R-Value Table http://www.coloradoenergy.org/procorner/stuff/r-values.htm
3 of 4 10/16/09 5:20 PM
Panel Door w/ 7/16" Panels (1 3/4")
1.85
Storm Door (wood 50% glass) 1.25 (metal) 1.00Metal Insulating (2" w/ urethane)
15.00
Air FilmsInterior Ceiling 0.61Interior Wall 0.68Exterior 0.17Air Spaces1/2" to 4" approximately 1.00
Back | Top
Hot Issues | Tips & Information | Communications CenterCalendar of Events | Colorado Activities | Energy Directory | Energy DataLaws/Legislation | Professionals Corner | Job AnnouncementsOther Sites | About COenergy | Site Map | Search | Home
2000-2009 ColoradoENERGY.orgThis site is currently maintained and hosted by Randy L. Martin of R. L. Martin & AssociatesComments on the site and notification of items that could be included can be sent to: email
Last Updated: 07/29/2008
ColoradoENERGY.org - R-Value Table http://www.coloradoenergy.org/procorner/stuff/r-values.htm
4 of 4 10/16/09 5:20 PM
D2
W2
D1
D1D1
D3D3 D3
D5
D1D2 D2D2
DW
F
7'-6
"30
'-4 5
/16"
10'-2
7/1
6"
7/16" 5 1/2" 8'-9 7/16" 6'-5" 5'-9 3/4" 3 1/2" 5'-8 1/2" 3 1/2" 2'-8 7/16" 3 1/2" 3'-4 1/2" 5 1/2"
5 1/
2"13
'-11
5/8"
3 1/
2"6'
-1/1
6"3'
-6 1
/16"
3 1/
2"
C2/A7.10
ANTIQUE VANITYBASE WITH LAV.
WATER HEATER
ATTIC ACCESS
12'-6"x14'-7"17'-5"x12'-5"
Foyer100
Master/Study101 Bedroom 1
102
M. Bath103
Bath104
SCALE: 1" = 1'-0"
A1 Cavity Wall 0 6'' 1' 2'
SCALE: 3/4" = 1'-0"
A2Wall Section 0 1' 2' 3'
SCALE: 1/4" = 1'-0"
D2 Mechanical Room at Attic 0 2' 4' 8'
1. Collection surface and gutters:
1. Collection surface and gutters1. Collection surface and gutters
Rainwater Collection
A4.23
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1813
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Framing Details
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
A4.22
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1812
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Framing Details
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
A4.21
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1811
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Framing & WaterProofing
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.esplanade
esplanade
esplanade
esplanade
esplanade
esplanade
esplanade
esplanade
esplanade
esplanade
esplanade
esplanade
A4.12
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
1810
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Building Sections
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
D C B A
11'-9" 11'-9" 11'-9"
-1'-7"-1 Foundation Plan
-1'-7"-1 Foundation Plan
0"1 1st Floor
0"1 1st Floor
SCALE: 1/4" = 1'-0"
B5N-S Building Section 0 2' 4' 8'
A4.11
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
189
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Building Sections
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
-1'-7"-1 Foundation Plan
-1'-7"-1 Foundation Plan
0"1 1st Floor
0"1 1st Floor
1 2
21'-6 3/8"
-1'-7"-1 Foundation Plan
0"1 1st Floor
SCALE: 1/4" = 1'-0"
C4N-S Building Section 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
A4N-S Building Section 0 2' 4' 8'
A3.12
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
188
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Building Elevations
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
SCALE: 1/4" = 1'-0"
C5West Elevation 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
A5 East Elevation 0 2' 4' 8'
A3.11
Thursday, April 22, 2010 1:22 PM
REG
IS
TERED ARCHITEC
T
STATE O F TEXA
S
M
ichael R. Kelle r
18068
187
studio.prime:2009:09004_walker:04_condocs:09004_Walker_prj08.pln
Legal NotesTHE SEAL APPEARING ON THISDOCUMENT WAS AUTHORIZED BYMICHAEL R. KELLER, AIA, TEXAS#18068. THE ORIGINAL SIGNEDDOCUMENT IS HELD AT THE OFFICEOF KELLER ARCHITECTURE.
Texas Cottage#StreetCat Spring, Texas 78006
Job Number: 09004Client: The Walkers
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
SHEET ____ OF ____
Document InformationCAD FILE NAME: 09004_Walker_prj08.pln
DESIGNED BY: MrK DRAWN BY: gj CHECKED BY: MrK COPYRIGHT: keller architecture - 2009
Building Elevations
conceptual
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Drawing Issue:
THIS PLAN AND THE DESIGNS CONTAINED HEREIN ARE THE PROPERTY OF KELLER ARCHITECTURE : DESIGNER. THIS DRAWING SET AND ALL OF ITS CONTENTS ARE SUBJECT TO COPYRIGHT AND MAY NOT BE RESOLD, TRANSFERRED OR REPRODUCED ALL OR IN PART, WITHOUT PRIOR WRITTEN CONSENT FROM THE DESIGNER OR HIS ASSIGNS.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT THE JOB SITE. THE DESIGNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PROJECT.
SCALE: 1/4" = 1'-0"
A4 North Elevation 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
C4 South Elevation0 2' 4' 8'
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
All drawings here reference the 2003 International Building Code with City ofHouston amendments.
Do not scale drawings. Written dimensions take precedence. Contractor toverify and be responsible for all dimensions and conditions on the job andnotify Paradigm Design inc. of any variations from the dimensions or conditionsshown on the drawings presented herein.
All written notes on these drawings shall take precedence over the minimumstandard notes detailed on A1.1.
All egress window sills are to a maximum of 44" above finished floor minimumopening are 24" high. 20" wide AND minimum 5.7 sq. ft net clear opening.There shall be at least one egress window per bedroom.
Openings on a 1 hour fire-rated exterior wall shall be protected with anassembly having a fire-protection rating of not less than ! hour. See IBC 2003,Sects. 7144.3.7 and 714.3.9 and table 714.2 (exterior walls). Penetrations into orthrough fire-rated walls shall conform to IBC 20003 sect. 711.3. Builder shalldetermine final material and provide appropriate test criteria to the localauthority.
Provide safety glazing in all hazardous locations listed in IBC sect.308.4.1-10excluding only listed exceptions.
All railing (wood, metal, or precast) shall have a 4" maximum spacingbetween balusters (spindles) and to conform to IBC sect. R316. Handrails andguardrails shall be designed for minimum live load found in IBC table R301.4and on A1.1. a. INTERIOR guards shall not be constructed with horizontal rails or other ornamental pattern that results in a ladder effect (IRBC sect R316.2) b. EXTERIOR guards to have railing no lower than 42" from finished floor, with no less than 36" distance from the top guard to bottom of lowest runner. Maximum unsupported span of lowest runner shall be 6'-0".
Roof plate heights are taken from nominal (first) floor slab level unlessotherwise noted.
All brick or prefab fireplaces to be built and installed per IBC Chapter 10 andbe U.L. and ICBO approved. A copy of the manufa