104
4-1 Catalogue HY11-2500/UK Relief valves EVSA Manual adjustment 6, 10 3, 5 4- 3 VSA Manual adjustment 6, 10 3, 5 4- 3 VS, VB Manual adjustment 6, 10 3, 5 4- 7 R Manual adjustment 16-63 4-13 ... ... 25 8 4-13 RS Manual adjustment 16-63 4-19 ... with electrical unloading 25 8 4-19 DSDU No adjustment, 16-32 4-27 with TÜV Certificate 25 8 4-27 VBY*A Manual adjustment 6, 10 3, 5 4-33 RE06M*W Proportional adjustment, 6 3 4-39 without onboard electronics RE06M*T Proportional adjustment, 6 3 4-43 with onboard electronics RE*W Proportional adjustment, 16-63 4-49 ... without onboard electronics 25 8 4-49 RE*T Proportional adjustment, 16-63 4-57 ... with onboard electronics 25 8 4-57 VBY*L Proportional adjustment, 6, 10 3, 5 4-65 without onboard electronics Reducing valves VM Manual adjustment 6, 10 3, 5 4-71 DWL, DWK Manual adjustment 10, 25, 32 5, 8, 10 4-77 VMY*L*N Proportional adjustment, 6 3 4-81 without onboard electronics VMY*L Proportional adjustment, 10 5 4-87 without onboard electronics DWE, DWU Proportional adjustment, 10, 25, 32 5, 8, 10 4-91 without onboard electronics PE, PC Proportional adjustment, 10, 25, 32 5, 8, 10 4-97 with onboard electronics Accessories Connectors 4-103 Chapter 4: Pressure Valves Contents If you are interested in fast delivery, please fol- low this hint in our ordering codes when choos- ing your individual product: Series Description DIN CETOP Page Operation Pilot Direct Nominal sizes Type Mounting Spool Seated Slip-in Screw-in Subplate 4

Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

Embed Size (px)

Citation preview

Page 1: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-1

Catalogue HY11-2500/UK

Relief valves

EVSA Manual adjustment • • • 6, 10 3, 5 4- 3VSA Manual adjustment • • • 6, 10 3, 5 4- 3

VS, VB Manual adjustment • • • 6, 10 3, 5 4- 7

R Manual adjustment • • • 16-63 4-13... ... • • • 25 8 4-13

RS Manual adjustment • • • 16-63 4-19... with electrical unloading • • 25 8 4-19

DSDU No adjustment, • • • 16-32 4-27with TÜV Certificate • • • 25 8 4-27

VBY*A Manual adjustment • • • 6, 10 3, 5 4-33

RE06M*W Proportional adjustment, • • • 6 3 4-39without onboard electronics

RE06M*T Proportional adjustment, • • • 6 3 4-43with onboard electronics

RE*W Proportional adjustment, • • • 16-63 4-49... without onboard electronics • • • 25 8 4-49

RE*T Proportional adjustment, • • • 16-63 4-57... with onboard electronics • • • 25 8 4-57

VBY*L Proportional adjustment, • • • 6, 10 3, 5 4-65without onboard electronics

Reducing valves

VM Manual adjustment • • • 6, 10 3, 5 4-71

DWL, DWK Manual adjustment • • • 10, 25, 32 5, 8, 10 4-77

VMY*L*N Proportional adjustment, • • • 6 3 4-81without onboard electronics

VMY*L Proportional adjustment, • • • 10 5 4-87without onboard electronics

DWE, DWU Proportional adjustment, • • • 10, 25, 32 5, 8, 10 4-91without onboard electronics

PE, PC Proportional adjustment, • • • 10, 25, 32 5, 8, 10 4-97with onboard electronics

Accessories Connectors 4-103

Chapter 4:Pressure ValvesContents

If you are interested in fast delivery, please fol-low this hint in our ordering codes when choos-ing your individual product:

Series Description DIN CETOP Page

Operation

Pilo

t

Dire

ct

Nominal sizesType Mounting

Spo

ol

Sea

ted

Slip

-in

Scr

ew-in

Sub

plat

e

4

Page 2: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-2

Catalogue HY11-2500/UK

Notes

4

Page 3: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-3

EVSA-VSA.PM6.5 RH

Pressure Relief ValveSeries EVSA and VSA

Catalogue HY11-2500/UK

4

Code Design

E Cartridge valve

Pipeline oromit manifold mounting

CodeMax. setting

pressure

064 64 bar

160 160 bar

315 315 bar

Direct-controlled, dampened poppet valve with adjust-able spring loading. Three pressure stages withselectable maximum adjustment pressures of 64, 160,and 315 bar are available.

FunctionIf the fluid pressure exceeds the value adjusted on thepressure spring, then a connection via the valve poppetis enabled from P → T or A → B.

The integrated damping spool prevents pressure fluc-tuations in the transition region. The pressure setting isset using a adjusting screw, which is locked with a clamp-ing screw. The setting can be secured by means of acylinder lock if required.

Characteristics / Ordering Code

Types EVSA VSA

Design Block Pipeline- orinstallation manifold mounting

Actuator Adjustment by hand

Mounting position as desired

Operating pressure [bar] up to 315

Ambient temperature [°C] -20 to +80

Viscosity range [mm²/s] 12...230

Technical data

Design Nominal size /thread type*

Pressurerelief valve

Max.setting

pressure

Adjustmentscrew

with hex.socket

A

Seal Designseries

VSA

Lock

Code Nominal size

06 NG06, M28x1.5 (EVSA)10 NG10, M35x1.5 (EVSA)06 NG06, DIN 24340 form A (VSA)10 NG10, DIN 24340 form D (VSA)

Code Seal

1 FPM for EVSA

2 FPM for VSA

Code Lock

omit without lock

Z Cylinder lock

EVSA 064 A10

Ordering code

NoteWhen you disassembe the screw-in cartridge, the springmust be unloaded.

Note about subplatesIn chapter 8/ subplate, you will find the type A064 R¼”OC1 or SPD 23 B910 to be used with VSA NG06 andthe type A102 R½” OD1 to be used with VSA NG10.

Page 4: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-4

EVSA-VSA.PM6.5 RH

Pressure Relief ValveSeries EVSA and VSA

Catalogue HY11-2500/UK

4

Characteristic Curves

∆∆∆∆∆p/Q performance curves NG06measured at t = 50°C and υ = 36 mm²/s

Setting pressure max. 64 bar

Setting pressure max. 315 bar

Setting pressure max. 160 bar

∆∆∆∆∆p/Q performance curves NG10measured at t = 50°C and υ = 36 mm²/s

Setting pressure max. 64 bar

Setting pressure max. 160 bar

Setting pressure max. 315 bar

Page 5: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-5

EVSA-VSA.PM6.5 RH

Pressure Relief ValveSeries EVSA and VSA

Catalogue HY11-2500/UK

4

Dimensions

Installation dimensions

EVSA NG10

EVSA NG06

Size M D1 D2 D3 D4 D5 L1 L2 L3 L4 L5 L6

NG06 M28 x 1.5 Ø24.8 Ø15 Ø6.8 Ø25H9 Ø6.8 15 19 30 35 45 65

NG10 M35 x 1.5 Ø31.8 Ø18.5 Ø10 Ø32H9 Ø10 18 23 35 41 - 46 52 80

SK-EVSAA0613

SK-EVSAA1013

Page 6: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-6

EVSA-VSA.PM6.5 RH

Pressure Relief ValveSeries EVSA and VSA

Catalogue HY11-2500/UK

4

Dimensions

VSA NG 10

VSA NG 06

Mounting pattern NG10DIN 24 340 form D, CETOP, ISO

NBR

BK364 M10 x 65 65 Nm SK-VSA-1021DIN 912 12.9

Surface finish

NBR

BK300 M5 x 50 8.1 Nm SK-VSA-0623DIN 912 12.9

Surface finish

Mounting pattern NG6DIN 24 340 form A, CETOP, ISO

Page 7: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-7

VB-VS.PM6.5 RH

Direct Operated Pressure ValveSeries VS and VB

Catalogue HY11-2500/UK

4

Characteristics

VS*A06*

Features

• Spool type valve

• Manifold mounting

• Type VS* with internal drain

• Type VB* with external drain

• 5 pressure stages at NG06

• 3 pressure stages at NG10

• 2 adjustment modes

Direct operated pressure valve with manual adjustment.

NG06 NG10

VB*A06*

VB*A10*

Description VS

The pressure relief valve VS*06 is a direct grated spoolvalve for subplate mounting with internal drain to port T.The connection and function is according to:

DIN 24340-C6-2.

Description VB

The sequence valve VB is a direct operated spool valvewith external drain. The sequence valve also allows theapplication as a pressure relief valve. The connectionand function is according to:

DIN 24340-C6-1 (NG06) and

DIN 24340-D10-1 (NG10).

Page 8: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-8

VS-VB.PM6.5 RH

Direct Operated Pressure ValveSeries VS and VB

Catalogue HY11-2500/UK

4

Code Function

Sequence orB pressure relief

S1) Pressure relief

CodeMax. setting

pressure

0251) 25 bar

064 64 bar

1252) 125 bar

1601) 160 bar

210 210 bar

3501) 350 bar

Max.setting

pressure

Adjustmentscrewwith

hexagonsocket

Nominalsize

FPMSeal

Designseries

V

Lock

Code Nominal size

06 NG 06

10 NG 10

Code Lock

omit normal

Z Cylinder lock

Function

1) NG06 only2) NG10 only

Gaugeport

Code Gauge port

G1) G ¼"

M M18x1.52)

M12x1.51)

C1) Coupling M16

V

Ordering Code / Technical Data

A

Technical data

General

Function Pressure relief valve VS Sequence and pressure relief valve VB

Nominal size DIN / CETOP 06 /03 06 / 03 10 / 05

Interface DIN 24340-C6-2 DIN 24340-C6-1 DIN 24340-D10-1

Mounting position unrestricted

Environmental temperature [°C] -20...+70

Weight [kg] 1.3 3.7

Hydraulics

Working pressure [bar] Port P 210 Port P and A 210 Port A and B 210Port T depressurized Port T depressurized Port Y depressurized

Adjustment range [bar] to 25; 64; 160; 210; 350 to 64; 125; 210

Nominal flow [l/min] 25 60

Pressure fluid Hydraulic oil according to DIN 51524...525

Pressure fluid temperature [°C] recommended +30...+50permitted -20...+70

Viscosity [mm²/s] recommended 30...50permitted 20...380

Max. contamination level NAS 1638 class 9, to achieve with β10>75

Ordering code

Page 9: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-9

VB-VS.PM6.5 RH

Direct Operated Pressure ValveSeries VS and VB

Catalogue HY11-2500/UK

4

Characteristic Curves

p/Q performance curves VS, VB NG06

Setting pressure max. 25 bar

Setting pressure max. 160 or 210 bar

Setting pressure max. 64 bar

p/Q performance curves VB NG10

Setting pressure max. 64 bar

Setting pressure max. 210 bar

Page 10: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-10

VS-VB.PM6.5 RH

Direct Operated Pressure ValveSeries VS and VB

Catalogue HY11-2500/UK

4

Dimensions

NG06

Mounting pattern DIN 24340-C6-1 Mounting pattern DIN 24340-C6-2

FPM

BK375 4 x M5x30 8.1Nm SK-VB/VM/VS-A06VDIN 912 12.9

Surface finish

body length 80

46

max. 7.2 M5-10deepØ4.2x4deep

12.5 40.5±0.1

21.5±0.2

12.7±0.2

30.2±0.2

33

32.5

±0.

1

31±

0.1

25.9

±0.

2

15.5

±0.

2

5.1±

0.2

0.75

±0.

1

A

T

B

P

body length 80

46

max. 7.2 M5-10deep

Ø4.2x4deep

12.5 40.5±0.1

21.5±0.2

12.7±0.2

30.2±0.2

33

32.5

±0.

1

31±

0.1

25.9

±0.

2

15.5

±0.

2

5.1±

0.2

0.75

±0.

1

A

T

B

P

Page 11: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-11

VB-VS.PM6.5 RH

Direct Operated Pressure ValveSeries VS and VB

Catalogue HY11-2500/UK

4

Dimensions

NG10

FPM

BK389 4 x M10x50 65Nm SK-VB/VM-A10VDIN 912 12.9

Surface finish

33.3

58.7

66.7

84m

in

92m

ax

7.9

7.1

4.8 M10

21.4

42.9

61

35.7

31.8

Y

X

A B14.7

21.4

7.5

Mounting pattern DIN 24340-D10-1

Page 12: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-12

VS-VB.PM6.5 RH

Direct Operated Pressure ValveSeries VS and VB

Catalogue HY11-2500/UK

4

Notes

Page 13: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-13

R.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries R

Catalogue HY11-2500/UK

4

Characteristics

Features• Pilot operated with manual adjustment

• 2 interfaces- subplate, DIN 24340-D10-2- slip-in, mounting hole acc. to DIN ISO 7368

• 4 pressure stages

• 2 adjustment modes- screw with lock nut- DIN lock

• Remote control via port X

The pressure relief valves series R consist of a manualadjustment pilot stage and a cartridge main stage.

Subplate valve R*MSlip-in valve R*E

10

9

Plate onlyat NG 50and NG 6325

X Y

A T

A

B

Page 14: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-14

R.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries R

Catalogue HY11-2500/UK

4

Ordering Code / Technical Data

General

Nominal size 25 16 25 32 40 50 63

Interface Subplate mounting Slip-in mountingDIN 24340-D10-2 hole acc. to DIN ISO 7368

Mounting position as desired, horizontal mounting prefered

Ambient temperature [°C] -20...+80

Weight [kg] 6.3 2.2 3.5 4.9 8.0 13.7 22.8

Hydraulics

Operating pressure [bar] Ports A and X up to 350, connection B and Y depressurized, solenoid up to 210

Pressure stages [bar] 105, 175, 250, 350

Nominal flow [l/min] 400 220 500 950 1400 2300 4000

Pressure medium Hydraulic oil according to DIN 51524 ... 525

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 20 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +70

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Ordering code

Technical data

Code Adjustment

Hexagon screwS with lock nut

L DIN lock

Adjustment

Pilot oil

Code Pilot Drain

1 internal external

41) internal internalCode Interface

M Subplate(DIN 24340-D10-2)

E Slip-in (holeDIN ISO 7368)

Pilot operatedpressure

relief valve

Nominalsize

Interface Pressurestages

Pilot

Code Pressure stages

10 up to 70bar17 up to 175bar25 up to 250bar35 up to 350bar

Poppetspring

Seals

R

Series

Code Seals

N NBR

V FPM

Interface M25 NG25 subplate

16 NG1625 NG2532 NG32 Interface E40 NG40 slip-in50 NG5063 NG63

Code Nominal size / Mounting

1) only interface M

S

Page 15: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-15

R.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries R

Catalogue HY11-2500/UK

4

Characteristic Curves

∆∆∆∆∆p/Q performance curve

p/Q performance curve

Page 16: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-16

R.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries R

Catalogue HY11-2500/UK

4

Dimensions

Dimensions R*E

Size H b1 d1 d2 t2

NG16 40 79 1) 32 25 58

NG25 45 85 45 34 72

NG32 93 102 60 45 85

NG40 103 125 75 55 105

NG50 138 140 90 68 122

NG63 153 180 120 90 155

1) width 65mm

NG NBR FPM

16 BK414 4 x M8x50 33Nm SK-R16E SK-R16EV25 BK391 4 x M12x50 115Nm SK-R25E SK-R25EV32 BK415 4 x M16x55 281Nm SK-R32E SK-R32EV40 BK416 4 x M20x70 553Nm SK-R40E SK-R40EV50 BK417 4 x M20x75 553Nm SK-R50E SK-R50EV63 BK418 4 x M30x100 1910Nm SK-R63E SK-R63EV

Page 17: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-17

R.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries R

Catalogue HY11-2500/UK

4

Dimensions

* only with c4max and t4max

NG b1 d1 H7 d2 H7 d3 d3 max d4 d4 max* d5 max d6 d7 H13 m1±0.2 m2±0.2 m3±0.2

16 65 32 25 16 18 16 25 4 M 8 4 46 25 23

25 85 45 34 25 25,5 25 32 6 M 12 6 58 33 29

32 102 60 45 32 36 32 40 8 M 16 6 70 41 35

40 125 75 55 40 43 40 50 10 M 20 6 85 50 42,5

50 140 90 68 50 56 50 63 10 M 20 8 100 58 50

63 180 120 90 63 74 63 80 12 M 30 8 125 75 62,5

NG m4±0.2 t1+0.1 t2+0.1 t3 t4 t4 max* t15 t6 t7 t8 t10 U W

16 10,5 43 56 11 34 29,5 20 20 2 2 10 0,03 0,05

25 16 58 72 12 44 40,5 30 25 2,5 2,5 10 0,03 0,05

32 17 70 85 13 52 48,0 30 35 2,5 2,5 10 0,03 0,1

40 23 87 105 15 64 59,0 30 45 3 3 10 0,05 0,1

50 30 100 122 17 72 65,5 35 45 4 3 10 0,05 0,1

63 38 130 155 20 95 86,5 40 65 4 4 10 0,05 0,2

Mounting dimensions R*E

Surface finish:

= Rmax

16, =√1 2 √ Rmax

8

Page 18: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-18

R.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries R

Catalogue HY11-2500/UK

4

Dimensions

Dimensions R*M

NG NBR FPM

25 BK395 4 x M10x100 65Nm SK-R25M SK-R25MV

Mounting pattern DIN 24340-D10-2

Page 19: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-19

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Characteristics

The pressure relief valve series RS* consist of a manualadjusted pilot stage with a directional valve for electrcallycontrolled unloading and a cartridge main part.

Features• Pilot operated with manual adjustment

• 2 interfaces- subplate, DIN 24340-D10-2- slip-in, mounting hole acc. to DIN ISO 7368

• 4 pressure stages

• 2 switching types

• 2 adjustment modes- screw with lock nut- DIN lock

• Remote control via port X

Subplate valve RS*MSlip-in valve RS*E

Plate onlywith G 50und NG 63

25

X

1

3

Y

A

B

2

43

2

A T

AT

10

9

Switching type 1 Switching type 9

Page 20: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-20

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Ordering Code

RS

Code Seals

N NBR

V FPM

Code Switching type

1Solenoid not activ.unpress. circulation

9Solenoid activatedunpress. circulation

Code Solenoid*

K 12VJ 24VU 98VG 198V

Switchingtype

Solenoid

S W

* use plug with rectifier at AC

Adjust-ment

Pressurerelief valvewith elec.unloading

Nominalsize

Interface Pressurestages

Pilot Poppetspring

Seals Series

Interface M25 NG25 subplate

16 NG1625 NG2532 NG32 Interface E40 NG40 slip-in50 NG5063 NG63

Code Nominal size / Mounting

Code Interface

M Subplate(DIN 24340-D10-2)

E Slip-in (holeDIN ISO 7368)

Code Pressure stages

07 up to 70bar17 up to 175bar25 up to 250bar35 up to 350bar

Code Adjustment

Hexagon screwS with lock nut

L DIN lock

Pilot oil

Code Pilot Drain

1 internal external

41) internal internal

1) only interface M

Withoutplug

Page 21: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-21

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Technical Data / Performance Curves

Technical data

∆∆∆∆∆p/Q performance curve

p/Q performance curve

General

Nominal size 25 16 25 32 40 50 63

Interface Subplate mounting Slip-in mountingDIN 24340-D10-2 hole acc. to DIN ISO 7368

Mounting position as desired, horizontal mounting prefered

Ambient temperature [°C] -20...+80

Weight [kg] 7.8 3.7 5 6.4 9.5 15.2 24.3

Hydraulics

Operating pressure [bar] Ports A and X up to 350, connection B and Y depressurized

Pressure stages [bar] 105, 175, 250, 350

Nominal flow [l/min] 400 220 500 950 1400 2300 4000

Pressure medium Hydraulic oil according to DIN 51524 ... 525

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 20 ... 380

Pressure medium temperaturerecommended [° C] 30 ... 50maximum [° C] -20 ... +70

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Electrical (prop. solenoid)Duty cycle [%] 100 ED

Plug connectors 2pole + PE / connector acc. to EN 175301-803

Protection class IP54 at DIN 40050 (plugged and mounted)

Direct current [V] Code Power [W] Current [A]

12 K 2.5

24 J30

1.25

98 U 0.31

198 G 0.15

Response time [ms] energized / deenergized 32 / 40

Switching frequency max. 15000 switchings/hour

Page 22: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-22

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Dimensions

Dimensions RS*E

Size H b1 d1 d2 t2

NG16 177 79 1) 32 25 56

NG25 181 85 45 34 72

NG32 186 102 60 45 85

NG40 196 125 75 55 105

NG50 231 140 90 68 122

NG63 246 180 120 90 155

1) width 65mm

46

Lmax.

123 (D.C.Solenoid)

B = max. overall lengthtotal

t2

X

A

NG 16NG 25

B

Y

Ød2Ød1

26

H

98 (V2)

145 (V61) 26

b1

10

91

09

X Y

NG NBR FPM

16 BK414 4 x M8x50 33Nm SK-RS16E SK-RS16EV25 BK391 4 x M12x50 115Nm SK-RS25E SK-RS25EV32 BK415 4 x M16x55 281Nm SK-RS32E SK-RS32EV40 BK416 4 x M20x70 553Nm SK-RS40E SK-RS40EV50 BK417 4 x M20x75 553Nm SK-RS50E SK-RS50EV63 BK418 4 x M30x100 1910Nm SK-RS63E SK-RS63EV

Page 23: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-23

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Dimensions

* only with c4max and t4max

NG b1 d1 H7 d2 H7 d3 d3 max d4 d4 max* d5 max d6 d7 H13 m1±0.2 m2±0.2 m3±0.2

16 65 32 25 16 18 16 25 4 M 8 4 46 25 23

25 85 45 34 25 25,5 25 32 6 M 12 6 58 33 29

32 102 60 45 32 36 32 40 8 M 16 6 70 41 35

40 125 75 55 40 43 40 50 10 M 20 6 85 50 42,5

50 140 90 68 50 56 50 63 10 M 20 8 100 58 50

63 180 120 90 63 74 63 80 12 M 30 8 125 75 62,5

NG m4±0.2 t1+0.1 t2+0.1 t3 t4 t4 max* t15 t6 t7 t8 t10 U W

16 10,5 43 56 11 34 29,5 20 20 2 2 10 0,03 0,05

25 16 58 72 12 44 40,5 30 25 2,5 2,5 10 0,03 0,05

32 17 70 85 13 52 48,0 30 35 2,5 2,5 10 0,03 0,1

40 23 87 105 15 64 59,0 30 45 3 3 10 0,05 0,1

50 30 100 122 17 72 65,5 35 45 4 3 10 0,05 0,1

63 38 130 155 20 95 86,5 40 65 4 4 10 0,05 0,2

Mounting dimensions R*E

Surface finish:

= Rmax

16, =√1 2 √ Rmax

8

Page 24: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-24

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Dimensions

Dimensions RS*M

100

215

79.4

10.3 11.1

32.9

44

60.3

11

142191

117

26

26

10

91

09

Ø38

NG NBR FPM

25 BK395 4 x M10x100 65Nm SK-RS25M SK-RS25MV

Page 25: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-25

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Dimensions

Mounting pattern DIN 24340-D10-2

Page 26: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-26

RS.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RS

Catalogue HY11-2500/UK

4

Notes

Page 27: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-27

DSDU.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries DSDU

Catalogue HY11-2500/UK

4

Characteristics

The pilot operated pressure relief valves series DSDUlimit the system pressure by opening the pressure port tothe tank. Valves of this design series have a flat p/Q curve.They are mostly used for accumulator pressure relief. Inthis case the valve is set and sealed by TÜV (GermanTechnical Monitoring Association). The valve deliveryincludes a copy of the TÜV certificate.

Features• TÜV certificate

• 2 interfaces

- subplate according to DIN 24340-D10-2

- slip-in, mounting hole acc. to DIN ISO 7368

• Flat p/Q curve

• Remote control via port XSlip-in Valve Subplate Valve

Subplate valve DSDU*P20Slip-in valve DSDU*E*

Page 28: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-28

DSDU.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries DSDU

Catalogue HY11-2500/UK

4

Ordering Code / Technical Data

Ordering code

Ordering Examples

DSDU 1078 E32 E - 120bar matches with: Gmax 550 l/min, opening pressure 120bar

DSDU 1078 E32 E - 150bar matches with: Gmax

640 l/min, opening pressure 150bar

Code Seals

omit NBR

V FPM

Seals Pressurelimiting

valve

Desiredopeningpressure

in bar(pleasespecify)

DSDU

Typecode

PressureStage

TÜV

Type Code

578 P20 1078 E16 1078 E25 1078 E32

Qmax [l/min] depending. on opening press.

220 150 215 500

240 165 235 550265 190 280 640

300 215 310 750320 230 355 800

345 255 390 900370 280 400 950

Opening

Pressure Ranges

[bar]

50 - 75

76 - 125126 - 175

176 - 200201 - 250

251 - 300301 - 350

Pressurestage

B

E

G

K

General

Size P20 E16 E25 E32

Interface subplate mounting Slip-in mountingDIN 24340-D10-2 DIN ISO 7368

Mounting position as desired, horizontal mounting prefered

Ambient temperature [°C] -20...+80

Weight [kg] 4.6 2.2 3.5 4.9

Hydraulics

Operating pressure [bar] Ports A and X up to 350, B and Y depressurized

Pilot internal / internal external / external

Adjustment pressure [bar] see ordering code

Nominal flow [l/min] see ordering code

Pressure medium Hydraulic oil according to DIN 51524 ... 525

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 12 ... 230

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -5 ... +80

Technical data

Page 29: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-29

DSDU.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries DSDU

Catalogue HY11-2500/UK

4

TÜV certificate

p/Q curves

Certificate / p/Q Curves

Page 30: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-30

DSDU.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries DSDU

Catalogue HY11-2500/UK

4

Dimensions

Dimensions DSDU*E*

Size H H1 B L

E16 140 84 79* 142

E25 160 88 85 152

E32 178 93 102 160

Mounting NG NBR FPM

16 BK414 4 x M8x50 33Nm SK-DSDU10-E16 SK-DSDU10-E16VSlip-in 25 BK391 4 x M12x50 115Nm SK-DSDU10-E25 SK-DSDU10-E25V

32 BK415 4 x M16x55 281Nm SK-DSDU10-E32 SK-DSDU10-E32V

Page 31: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-31

DSDU.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries DSDU

Catalogue HY11-2500/UK

4

Dimensions

NG b1 d1 H7 d2 H7 d3 d3 max d4 d4 max* d5 max d6 d7 H13 m1±0.2 m2±0.2 m3±0.2

16 65 32 25 16 18 16 25 4 M 8 4 46 25 23

25 85 45 34 25 25.5 25 32 6 M 12 6 58 33 29

32 102 60 45 32 36 32 40 8 M 16 6 70 41 35

NG m4±0.2 t1+0.1 t2+0.1 t3 t4 t4 max* t15 t6 t7 t8 t10 U W

16 10.5 43 56 11 34 29.5 20 20 2 2 10 0.03 0.05

25 16 58 72 12 44 40.5 30 25 2.5 2.5 10 0.03 0.05

32 17 70 85 13 52 48.0 30 35 2.5 2.5 10 0.03 0.1

Mounting dimensions

Surface finish:

= Rmax

16, =√1 2 √ Rmax

8

Page 32: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-32

DSDU.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries DSDU

Catalogue HY11-2500/UK

4

Dimensions DSDU*P20

Dimensions

Mounting pattern DIN 24340-D10-2

Size NBR FPM

P20 BK388 4 x M10x40 65Nm SK-DSDU5P20 SK-DSDU5P20V

Page 33: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-33

VBY-A.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*A

Catalogue HY11-2500/UK

4

Pilot-operated pressure valves of the series VBY*A con-sist of a pilot with manual adjustment and a main partwith spool execution. The relief valve has an externaldrain.

Characteristics

Features

• Manifold mounting- NG06 according to DIN 24340-C6-1- NG10 according to DIN 24340-D10-1

• Type VBY*A with external drain

• Main stage spool type valve

• Pilot stage seated type valve

• 4 pressure stages

• 2 adjustment modes- screw with hexagon socket- DIN knob

NG06 NG10

NG06 NG10

NG06 NG10

Page 34: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-34

VBY-A.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*A

Catalogue HY11-2500/UK

4

Ordering Code / Technical Data

CodeMax. setting

range

064 64 bar160 160 bar210 210 bar315 315 bar

Nominalsize

Pressurerelief valve

Max.settingrange

Operation

Code Operation

A Adjustment screww. hexagon socket

H Turning knob w.cylinder lock

Seal

Code Seal

N NBR

V FPM

V

Ordering code

Y

Code Nominal size

06 NG06

10 NG10

Designseries

B

Technical data

Nominal size NG06 NG10

Design Main stage Spool directional control valvePilot stage Poppet valve

Mounting pattern DIN 24 340-C6-1 DIN 24 340-D10-1

Mounting position as desired

Ambient temperature [°C] max. +50

Operating pressure, ports [bar] P, A, B up to 315 A, B, X up to 315External drain port pressure [bar] T up to 100 Y up to 100

Adjustment stages [bar] 64, 160, 210, 315

Pressure fluid temperature [°C] max. +70

Viscosity range [mm²/s] 30...230

Volume flow [l/min] see p/Q curves

Pilot oil flow [cm³/min] approx. 500 approx. 1000

Weight [kg] 2.4 4.5

Page 35: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-35

VBY-A.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*A

Catalogue HY11-2500/UK

4

Characteristic Curves

Setting range max. 64 bar NG06

p/Q performance curves VBY*A NG06

Setting range max. 210 bar NG06

Setting range max. 160 bar NG06

Setting range max. 315 bar NG06

measured at t = 50°C and ν = 36 mm²/s

0 10 20 30 40Flow Q [l/min]

Pre

ssur

e p

[bar

]

0

10

20

30

40

50

60

70

80

p mine

Flow Q [l/min]

p mine

Pre

ssur

e p

[bar

] 8070605040302010

5

0 20 40 60 80 100 120 140 160

Setting range max. 64 barNG10

Setting range max. 210 bar NG10

Setting range max. 160 bar NG10

Setting range max. 315 bar NG10

p/Q performance curves VBY*A NG10measured at t = 50°C and ν = 36 mm²/s

Page 36: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-36

VBY-A.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*A

Catalogue HY11-2500/UK

4

Dimensions

NG06

Screw stud torqueMA = 7.5 ± 0.7Nm.Mounting screws(4 x M5 x 30 DIN912-10.9 are notincluded)

body length 80

46

max. 7.2 M5-10deepØ4.2x4deep

12.5 40.5±0.1

21.5±0.2

12.7±0.2

30.2±0.2

33

32.5

±0.

1

31±

0.1

25.9

±0.

2

15.5

±0.

2

5.1±

0.2

0.75

±0.

1

A

T

B

P

FPM

BK375 4 x M5x30 7.5Nm SK-VBY-A06VDIN 912 12.9

Surface finish

Mounting pattern DIN 24340-C6-1

Page 37: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-37

VBY-A.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*A

Catalogue HY11-2500/UK

4

Dimensions

NG10

FPM

BK389 4 x M10x50 65Nm SK-VB/VM-A10VDIN 912 12.9

Surface finish

Mounting pattern DIN 24340-D10-1

Page 38: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-38

VBY-A.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*A

Catalogue HY11-2500/UK

4

Notes

Page 39: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-39

RE06W.PM6.5 RH

Direct Acting Proportional Relief ValveSeries RE06M*W

Catalogue HY11-2500/UK

4

Characteristics

The proportional pressure relief valve RE06M*W allowsvariable adjustment from pmin up to nominal pressure. Atpower breakdown the valve is depressurized. Therebythe pressure pmin is depending on the flow rate.

Features

• Direct controlled via proportional solenoid

• Very low pressure adjustment of pmin

(see curves)

• 2 pressure inlet ports, A and P

• Subplate according to DIN24340-C6-2

• 4 pressure stages

FPMseals

Pressurerange

Solenoidvoltage

12V, 2.3A

PlugconnectionEN 175301-

803

RE

Series

W 1

Normalyopen

W

Code Pressure range

10 105bar

17 175bar

25 250bar

35 350bar

V

Externalelectronics

2M06

Mountingpattern

DIN23340-C6-2

NG06Proportionalpressure

relief valve

K

Ordering code

Page 40: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-40

RE06W.PM6.5 RH

Direct Acting Proportional Relief ValveSeries RE06M*W

Catalogue HY11-2500/UK

4

Technical Data

GeneralNominal size [DIN/CETOP] 06 / 03

Interface DIN 24340-C6-2

Mounting position as desired

Ambient temperature [°C] -20 ... +70

Weight [kg] 1.8

HydraulicsOperating pressure [bar] Ports P and A up to 350; port T depressurized; solenoid up to 210

Adjustment range [bar] up to 105, 175, 250, 350

Volume flow [l/min] see p/Q curves

Pressure medium Hydraulic oil as per DIN 51524 ... 525

Viscosity, recommended [mm²/s] 30 ... 80maximum [mm²/s] 12 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +60

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Linearity [%] ±2.8

Repeatability [%] <±1

Hysteresis [%] ±1.5 of pmax

Manufacturing tolerance [%] ±2.5 of pmax

ElectricalDuty cycle [%] 100 ED

Protection class IP54 at DIN 40050 (plugged and mounted)

Nominal voltage [V] 12

Max. current [A] 2.3

Ambient temperature [°C] -20...+60

Coil resistance [Ohm] 4 at 20°C

Plug connectors 2pole + PE / connector EN 175301-803 / cableØ 8...10mm

Power amplifier PCD00A-400

Page 41: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-41

RE06W.PM6.5 RH

Direct Acting Proportional Relief ValveSeries RE06M*W

Catalogue HY11-2500/UK

4

Characteristic p/Q curvesPressure stage 105bar Pressure stage 350bar

Characteristic pmin/Q curvesPressure stage 105bar Pressure stage 350bar

0 1 2 3 4 5Flow Q [l/min]

14

12

10

8

6

4

2

0

Pilo

t pre

ssur

e p

[bar

]m

in

0 1 2 3 4 5Flow Q [l/min]

35

30

25

20

15

10

5

0

Pilo

t pre

ssur

e p

[bar

]m

in

Characteristic pset-voltage curvesPressure stage 105bar Pressure stage 350bar

Characteristic Curves

Page 42: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-42

RE06W.PM6.5 RH

Direct Acting Proportional Relief ValveSeries RE06M*W

Catalogue HY11-2500/UK

4

Mounting pattern DIN24340-C6-2

max. 7.2M5-10deep

Body length 77

Bod

y w

idth

46

max

. nor

m w

idth

50

AT

P

1840.5±0.1

21.5±0.2

5.1±

0.2

15.5

±0.

2

25.9

±0.

2

32.5

±0.

1

0.75

±0.

1

31±

0.1

12.7±0.2

Dimensions

NBR FPM

BK375 4x M5x30 8,1 Nm SK-RE06MN_ SK-RE06MV_

Surface finish

��

Page 43: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-43

RE06MT.PM6.5 RH

Direct-Operated Proportional Pressure ValveSeries RE06M*T

Catalogue HY11-2500/UK

4

Characteristics

The proportional pressure relief valve series RE06M*Tallows variable adjustment from pmin up to nominal pres-sure. In case of power breakdown the valve is depressu-rized.

Thereby the pressure pmin is depending on the flow rate.

Features

• Direct-operated pressure relief valve

• On-board electronics

• Min/max option

• Ramp adjustment

• Command /pressure curve linearized

• Very low pressure adjustment of pmin

• Subplate mounting acc. to DIN 24340-C6-2

• 4 pressure stages

• 2 pressure inlet ports A and P

FPMseal

Pressurerange

Electronicdesign

Electronicattachment

RE

Series

T 1

Normalyopen

0

Code Pressure range

10 105bar

17 175bar

25 250bar

35 350bar

V

On-boardelectronics

2M06

Mountingpattern

DIN23340-C6-2

NG06Proportionalpressure

relief valve

Ordering code

Code Electronic design

Voltage inputF 0...+10V with refer-

ence output +10V

Current inputG0...20mA

Page 44: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-44

RE06MT.PM6.5 RH

Direct-Operated Proportional Pressure ValveSeries RE06M*T

Catalogue HY11-2500/UK

4

Technical Data

General

Nominal size 06

Interface DIN 24340-C6-2

Mounting position as desired, horizontal mounting prefered

Ambient temperature [°C] -20...+80

Weight [kg] 2.2

Hydraulics

Operating pressure [bar] Ports A and P up to 350, connection T depressurized, solenoid up to 210

Pressure stages [bar] 105, 175, 250, 350

Volume flow [l/min] see p/Q curves

Pressure medium Hydraulic oil according to DIN 51524 ... 525

Viscosity, recommended [mm²/s] 30 ... 80maximum [mm²/s] 12 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +60

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Linearity [%] see curve

Repeatability [%] <±1

Hysteresis [%] ±1.5 of pmax

Manufacturing tolerance [%] ±2.5 of pmax

ElectricalDuty cycle [%] 100 ED

Protection class IP54 at DIN 40050 (plugged and mounted)

Supply voltage [V] 14.5...30

Ripple in supply voltage [%] max. 5

Current consumption [A] 2.8

Ambient temperature [°C] -20...+80

Input rangevoltage input [V] 0...+10 max. / 10kOhmcurrent input [mA] 0...+20 / 500Ohm

Adjustment range of ramp time [s] 0...5

Installation cross-section min. 1mm² shielded

Cable length [m] max. 50

Plug connector No. 5004072; 6pole + PE / connector DIN 53563 / cableØ 8...10mm

Page 45: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-45

RE06MT.PM6.5 RH

Direct-Operated Proportional Pressure ValveSeries RE06M*T

Catalogue HY11-2500/UK

4

Command/pressure curve

Characteristic Curves

pmin/Q curves

p/Q curves

Page 46: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-46

RE06MT.PM6.5 RH

Direct-Operated Proportional Pressure ValveSeries RE06M*T

Catalogue HY11-2500/UK

4

Block diagram

Connector wiring diagram

Electronics

Page 47: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-47

RE06MT.PM6.5 RH

Direct-Operated Proportional Pressure ValveSeries RE06M*T

Catalogue HY11-2500/UK

4

Mounting pattern DIN 24340-C6-2

max. 7.2 M5-10deep

Body length 77

Bod

y w

idth

46

max

.nor

m w

idth

50

AT

P

18 40.5±0.1

21.5±0.2

5.1±

0.2

15.5

±0.

2

25.9

±0.

2

32.5

±0.

1

0.75

±0.

1

31±

0.1

12.7±0.2

Dimensions

NBR FPM

BK375 4x M5x30 8,1 Nm SK-RE06MN SK-RE06MV

Surface finish

Page 48: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-48

RE06MT.PM6.5 RH

Direct-Operated Proportional Pressure ValveSeries RE06M*T

Catalogue HY11-2500/UK

4

Notes

Page 49: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-49

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Characteristics

The pressure relief valve series RE*W has a proportio-nal solenoid operated pilot stage and a cartridge mainstage.

The control command signal is provided by externalelectronic modules.

Features• Pilot operated with proportional solenoid

• Very low pmin

pressure adjustment

• Continuously adjustment via proportional solenoid

• 2 interfaces

- subplate according to DIN 24340-D10-2

- slip-in, mounting hole according to DIN ISO 7368

• 4 pressure stages

Subplate valve RE*MSlip-in valve RE*E

Page 50: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-50

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Ordering Code

Pilot oil

Code Pilot Drain

1 internal external

41) internal internalCode Interface

M Subplate(DIN 24340-D10-2)

E Slip in (holeDIN ISO 7368)

Prop. pressure

relief valve

Off-boardelectronics

Nominalsize

Interface Pressurestages

Pilot

Code Pressure stages

10 up to 105bar17 up to 175bar25 up to 250bar35 up to 350bar

Poppetspring

Seals

RE

Series

Code Seals

N NBR

V FPM

Interface M25 NG25 subplate

16 NG1625 NG2532 NG32 Interface E40 NG40 slip-in50 NG5063 NG63

Code Nominal size / Mounting

1) only interface M

Normalyopen

Solenoid12V, 2.3A

S WW K1

max.protection

M

Page 51: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-51

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Technical Data

General

Nominal size 25 16 25 32 40 50 63

Interface Subplate mounting Slip-in mountingDIN 24340-D10-2 hole acc. to DIN ISO 7368

Mounting position as desired, horizontal mounting prefered

Ambient temperature [°C] -20...+80

Weight [kg] 6.3 2.2 3.5 4.9 8.0 13.7 22.8

Hydraulics

Operating pressure [bar] Ports A and X up to 350, connection B and Y depressurized, solenoid up to 210

Pressure stages [bar] 105, 175, 250, 350

Nominal flow [l/min] 400 220 500 950 1400 2300 4000

Pressure medium Hydraulic oil according to DIN 51524 ... 525

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 20 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +70

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Linearity [%] ±2.8

Repeatability [%] <±1

Hysteresis [%] ±1.5 of pmax

Manufacturing tolerance [%] ±2.5 of pmax

Electrical (prop. solenoid)Duty cycle [%] 100 ED

Protection class IP54 at DIN 40050 (plugged and mounted)

Nominal voltage [V] 12

Max. current [A] 2.3

Ambient temperature [°C] -20...+80

Coil resistance [Ohm] 4 at 20°C

Plug connectors 2pole + PE / connector EN 175301-803 / cableØ 8...10mm

Power amplifier PCD00A-400

Page 52: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-52

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Characteristic Curves

Signal/pressure curve RE*W

∆∆∆∆∆p/Q performance curve RE*W

p/Q performance curve RE*W

Page 53: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-53

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Dimensions

Dimensions RE*E*W

Size H b1 d1 d2 t2

NG16 177 79 1) 32 25 56

NG25 122 85 45 34 72

NG32 127 102 60 45 85

NG40 137 125 75 55 105

NG50 172 140 90 68 122

NG63 187 180 120 90 155

1) width 65mm

NG NBR FPM

16 BK414 4 x M8x50 33Nm SK-RE16E SK-RE16EV25 BK391 4 x M12x50 115Nm SK-RE25E SK-RE25EV32 BK415 4 x M16x55 281Nm SK-RE32E SK-RE32EV40 BK416 4 x M20x70 553Nm SK-RE40E SK-RE40EV50 BK417 4 x M20x75 553Nm SK-RE50E SK-RE50EV63 BK418 4 x M30x100 1910Nm SK-RE63E SK-RE63EV

Page 54: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-54

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Dimensions

Mounting dimensions RE*E*W

Surface finish:

= Rmax16, =√1 2 √ Rmax8

* only with c4max and t4max

NG b1 d1 H7 d2 H7 d3 d3 max d4 d4 max* d5 max d6 d7 H13 m1±0.2 m2±0.2 m3±0.2

16 65 32 25 16 18 16 25 4 M 8 4 46 25 23

25 85 45 34 25 25,5 25 32 6 M 12 6 58 33 29

32 102 60 45 32 36 32 40 8 M 16 6 70 41 35

40 125 75 55 40 43 40 50 10 M 20 6 85 50 42,5

50 140 90 68 50 56 50 63 10 M 20 8 100 58 50

63 180 120 90 63 74 63 80 12 M 30 8 125 75 62,5

NG m4±0.2 t1+0.1 t2+0.1 t3 t4 t4 max* t15 t6 t7 t8 t10 U W

16 10,5 43 56 11 34 29,5 20 20 2 2 10 0,03 0,05

25 16 58 72 12 44 40,5 30 25 2,5 2,5 10 0,03 0,05

32 17 70 85 13 52 48,0 30 35 2,5 2,5 10 0,03 0,1

40 23 87 105 15 64 59,0 30 45 3 3 10 0,05 0,1

50 30 100 122 17 72 65,5 35 45 4 3 10 0,05 0,1

63 38 130 155 20 95 86,5 40 65 4 4 10 0,05 0,2

Page 55: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-55

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Dimensions

Dimensions RE25M*W

NG NBR FPM

25 BK388 4 x M10x40 65Nm SK-RE25M SK-RE25MV

Page 56: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-56

RE W.PM6.5 RH

Pilot Operated Pressure Relief ValveSeries RE*W

Catalogue HY11-2500/UK

4

Mounting pattern DIN 24340-D10-2

Dimensions

Page 57: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-57

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Characteristics

Slip-in valve RE*E*T

The pressure relief valve series RE*T have a proportionalsolenoid operated pilot stage with integrated electronicsand a cartridge main stage.

Features

• Pilot-operated pressure relief valve

• On-board electronics

• Min/max option

• Ramp adjustment

• Very low pressure adjustment of pmin

• 4 pressure stages

• 2 interfaces:

- subplate mounting acc. to DIN 24340-D10-2

- slip-in, installation hole acc. to DIN ISO 7368

Subplate valve RE*M*T

Page 58: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-58

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Ordering Code

Propor-tional

pressurelimiting

valve

Nominalsize

Interface Pressurestages

Pilot Poppetspring

Seal

RE

On-boardelectronics

T

Electronicattach-ments

Normalyopen

1

Designseries

Specialequip-ment

Code Special equipment

omit without

Mechanical press.Mprotection

Elec-tronicdesign

0

Code Interface

M Subplate(DIN 24340-D10-2)

E Slip in (holeDIN ISO 7368)

Code Pressure stages

10 up to 105bar17 up to 175bar25 up to 250bar35 up to 350bar

Interface M25 NG25 subplate

16 NG1625 NG2532 NG32 Interface E40 NG40 slip-in50 NG5063 NG63

Code Nominal size / Mounting

N

Code Electronic design

Voltage inputF 0...+10V with refer-

ence output +10V

Current inputG0...20mA

Pilot oil

Code Pilot Drain

1 internal external

41) internal internal

1) only interface M

Code Seals

N NBR

V FPM

Page 59: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-59

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Technical Data

General

Nominal size 25 16 25 32 40 50 63

Interface Subplate mounting Slip-in mountingDIN 24340-D10-2 hole acc. to DIN ISO 7368

Mounting position as desired, horizontal mounting prefered

Ambient temperature [°C] -20...+80

Weight [kg] 6.3 2.2 3.5 4.9 8.0 13.7 22.8

Hydraulics

Operating pressure [bar] Ports A and X up to 350, connection B and Y depressurized, solenoid up to 210

Pressure stages [bar] 105, 175, 250, 350

Nominal flow [l/min] 400 220 500 950 1400 2300 4000

Pressure medium Hydraulic oil according to DIN 51524 ... 525

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 20 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +70

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Linearity [%] ±2.8

Repeatability [%] <±1

Hysteresis [%] ±1.5 of pmax

Manufacturing tolerance [%] ±2.5 of pmax

Electrical (prop. solenoid)Duty cycle [%] 100 ED

Protection class IP54 at DIN 40050 (plugged and mounted)

Supply voltage [V] 14.5...30

Ripple in supply voltage [%] max. 5

Current consumption [A] 2.8

Ambient temperature [°C] -20...+80

Input rangevoltage input [V] 0...+10 max. / 10kOhmcurrent input [mA] 0...+20 / 500Ohm

Adjustment range of ramp time [s] 0...5

Installation cross-section min. 1mm² shielded

Cable length [m] max. 50

Plug connector No. 5004072; 6pole + PE / connector DIN 53563 / cableØ 8...10mm

Page 60: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-60

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Block diagram of the electronics

Connector wiring diagram

Electronics

Page 61: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-61

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Command/pressure curve

Characteristic Curves

∆∆∆∆∆p/Q curves

p/Q curves

Page 62: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-62

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Dimensions

RE*E*T

Size H b1 d1 d2 t2

NG16 177 79 1) 32 25 56

NG25 122 85 45 34 72

NG32 127 102 60 45 85

NG40 137 125 75 55 105

NG50 172 140 90 68 122

NG63 187 180 120 90 155

1) width 65mm

NG NBR FPM

16 BK414 4 x M8x50 33Nm SK-RE16E SK-RE16EV25 BK391 4 x M12x50 115Nm SK-RE25E SK-RE25EV32 BK415 4 x M16x55 281Nm SK-RE32E SK-RE32EV40 BK416 4 x M20x70 553Nm SK-RE40E SK-RE40EV50 BK417 4 x M20x75 553Nm SK-RE50E SK-RE50EV63 BK418 4 x M30x100 1910Nm SK-RE63E SK-RE63EV

Page 63: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-63

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Dimensions

Mounting dimensions RE*E*W

Surface finish:

= Rmax16, =√1 2 √ Rmax8

* only with c4max and t4max

NG b1 d1 H7 d2 H7 d3 d3 max d4 d4 max* d5 max d6 d7 H13 m1±0.2 m2±0.2 m3±0.2

16 65 32 25 16 18 16 25 4 M 8 4 46 25 23

25 85 45 34 25 25,5 25 32 6 M 12 6 58 33 29

32 102 60 45 32 36 32 40 8 M 16 6 70 41 35

40 125 75 55 40 43 40 50 10 M 20 6 85 50 42,5

50 140 90 68 50 56 50 63 10 M 20 8 100 58 50

63 180 120 90 63 74 63 80 12 M 30 8 125 75 62,5

NG m4±0.2 t1+0.1 t2+0.1 t3 t4 t4 max* t15 t6 t7 t8 t10 U W

16 10,5 43 56 11 34 29,5 20 20 2 2 10 0,03 0,05

25 16 58 72 12 44 40,5 30 25 2,5 2,5 10 0,03 0,05

32 17 70 85 13 52 48,0 30 35 2,5 2,5 10 0,03 0,1

40 23 87 105 15 64 59,0 30 45 3 3 10 0,05 0,1

50 30 100 122 17 72 65,5 35 45 4 3 10 0,05 0,1

63 38 130 155 20 95 86,5 40 65 4 4 10 0,05 0,2

Page 64: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-64

RE T.PM6.5 RH

Proportional Pressure Relief ValveSeries RE*T

Catalogue HY11-2500/UK

4

Dimensions

RE*M*T

NG NBR FPM

25 BK388 4 x M10x40 65Nm SK-RE25M SK-RE25MV

Mounting pattern DIN 24340-D10-2

Page 65: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-65

VBY-L.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*L

Catalogue HY11-2500/UK

4

Description / Ordering Code

NG06 NG10

Features

• Proportional adjustment

• Manifold mountingNG06 to DIN 24340-C6-1NG10 to DIN 24340-D10-1

• Type VBY*L with external drain

• Main stage spool type valve

• Pilot stage seated type valve

Pilot operated pressure valve with proportional adjust-ment.

Function

The pressure valve VBY*L is pilot operated with externaldrain. The external drain allows an application as a se-quence and pressure relief valve. The port assignementis equivalent to DIN 24340-C6-1 (NG06) and DIN 24340-D10-1 (NG10).

NG06 NG10

NG06 NG10

Code Max. setting range

064 64bar100 100bar160 160bar210 210bar315 315bar

Nominalsize

Pressurevalve

Max.settingrange

Linearsolenoid

L

Seal Designseries

Code Seal

N NBR

V FPM

V Y

Ordering code

B

Code Nominal size

06 NG06

10 NG10

Page 66: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-66

VBY-L.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*L

Catalogue HY11-2500/UK

4

Technical Data / Characteristic Curves

Technical data

GeneralDesign type Proportional pressure valve

Nominal size [DIN/CETOP] 06 / 03 10 / 05

Interface DIN 24340-C6-1 DIN 24340-D10-1

Actuation Proportional solenoid

Mounting position as desired

Ambient temperature [°C] -20 ... +70

Weight [kg] 5

HydraulicsOperating pressure [bar] Ports P and A 315; Port T depressurized Ports A and B 315; Port Y depressurized

Nominal flow [l/min] 40 160

Adjustment range [bar] up to 64, 100, 160, 210, 315

Pressure medium Hydraulic oil as per DIN 51 524 ... 525

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 20 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +70

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Linearity [%] ±3.5 at > 15% pnom.

Repeatability [%] <±2

Hysteresis [%] ±1.5 to pmax

Response time [ms] <150 <200

Manufacturing tolerance [%] ±5 to pmax

ElectricalDuty cycle [%] 100 ED

Protection class IP54 at DIN 40050 (plugged and mounted)

Nominal voltage [V] 24

Max. current [mA] 800

Ambient temperature [°C] -20...+70

Coil resistance [Ohm] 21 at 20°C

Plug connectors 2pole + PE / connector EN 175301-803 / cableØ 8...10mm

Power amplifier PCD00A-400

Characteristic pressure lines for NG06 p = f (Uset)Setting range, max. 64 bar Setting range, max. 210 bar

Page 67: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-67

VBY-L.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*L

Catalogue HY11-2500/UK

4

Characteristic Curves

Setting range max. 315 bar

Setting range max. 64 bar

p/Q characteristics VBY-L NG06(measured at t = 50°C and ν = 35 mm²/s)

Setting range max. 100 bar

Setting range max. 160 bar Setting range max. 210 bar

Page 68: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-68

VBY-L.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*L

Catalogue HY11-2500/UK

4

Characteristic Curves

Step response signal VBY*L NG06(typical characteristic curve)setting range max. 210 bar

Setting range, max. 64 bar

p/Q characteristics VBY NG10

Setting range, max. 100 bar

measured at t = 50°C and ν = 35 mm²/s

Setting range, max. 160 bar Setting range, max. 210 bar

Page 69: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-69

VBY-L.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*L

Catalogue HY11-2500/UK

4

Dimensions

NG06

Mounting pattern DIN 24340-C6-1

The connection Bis to be lockedonto the subplatefor standard appli-cations.

NBR FPM

BK375 M5 x 30 7.5 Nm SK-VMY-L06-N SK-VMY-L06-VDIN 912 12.9

Surface finish

Page 70: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-70

VBY-L.PM6.5 RH

Pilot-Operated Pressure ValveSeries VBY*L

Catalogue HY11-2500/UK

4

Dimensions

NG10

FPM

BK389 4 x M10x50 65 Nm SK-VB/VM-A10VDIN 912 12.9

Surface finish

Mounting pattern NG10 DIN 24340-D10-1

Page 71: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-71

VM.PM6.5 RH

Direct Operated Pressure Reducing ValveSeries VM

Catalogue HY11-2500/UK

4

Characteristics

NG06

Features

• Spool type valve

• Manifold mountingNG06 to DIN 24340-C6-1NG10 to DIN 24340-D10-1

• 4 pressure stages at NG06

• 3 pressure stages at NG10

• 2 adjustment modes

Direct operated pressure reducing valve with manual ad-justment.

NG06 NG10

NG10

Function

The pressure reducing valve VM is a direct controlled,spring loaded 3 way pressure reducing valve, that is openin the neutral position. The valve closes the connectionfrom P to A (NG06) or B to A (NG10) when the pre-setpressure is exceeded.

If the pressure increases due to an externaly influencein connection A the spool moves and opens the connec-tion from A to T (NG06) or A to Y (NG10) until the pre-setpressure has been reached.

NG06 NG10

Page 72: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-72

VM.PM6.5 RH

Direct Operated Pressure Reducing ValveSeries VM

Catalogue HY11-2500/UK

4

CodeMax. setting

pressure

0251) 25 bar

064 64 bar

1252) 125 bar

1601) 160 bar

210 210 bar

3501) 350 bar

Max.setting

pressure

Adjustmentscrewwith

hexagonsocket

Nominalsize

FPMSeal

Designseries

V

Lock

Code Nominal size

06 NG 06

10 NG 10

Code Lock

omit normal

Z Cylinder lock

Pressurereducing

valve

1) NG06 only2) NG10 only

Gaugeport

Code Gauge port

G1) G ¼"

M M18x1.52)

M12x1.51)

C1) Coupling M16

V

Ordering Code / Technical Data

A

Technical data

General

Function Pressure reducing valve

Nominal size DIN / CETOP 06 / 03 10 / 05

Interface DIN 24340-C6-1 DIN 24340-D10-1

Mounting position unrestricted

Environmental temperature [°C] -20...+70

Weight [kg] 1.3 3.7

Hydraulics

Working pressure [bar] Port P and A 210 Port A and B 210Port T depressurized Port Y depressurized

Adjustment range [bar] to 25; 64; 160; 210; 350 to 64; 125; 210

Nominal flow [l/min] 25 60

Pressure fluid Hydraulic oil according to DIN 51524...525

Pressure fluid temperature [°C] recommended +30...+50permitted -20...+70

Viscosity [mm²/s] recommended 30...50permitted 20...380

Max. contamination level NAS 1638 class 9, to achieve with β10>75

Ordering code

M

Page 73: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-73

VM.PM6.5 RH

Direct Operated Pressure Reducing ValveSeries VM

Catalogue HY11-2500/UK

4

Characteristic Curves

p/Q performance curves VM NG06

Setting pressure max. 25 bar

Setting pressure max. 64 bar

Setting pressure max. 160 or 210 bar

p/Q performance curves VM NG10

Setting pressure max. 64 bar

Setting pressure max. 210 bar

Page 74: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-74

VM.PM6.5 RH

Direct Operated Pressure Reducing ValveSeries VM

Catalogue HY11-2500/UK

4

Dimensions

NG06

Mounting pattern DIN 24340-C6-1

FPM

BK375 4 x M5x30 8.1Nm SK-VB/VM/VS-A06VDIN 912 12.9

Surface finish

body length 80

46

max. 7.2 M5-10deepØ4.2x4deep

12.5 40.5±0.1

21.5±0.2

12.7±0.2

30.2±0.2

33

32.5

±0.

1

31±

0.1

25.9

±0.

2

15.5

±0.

2

5.1±

0.2

0.75

±0.

1

A

T

B

P

Page 75: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-75

VM.PM6.5 RH

Direct Operated Pressure Reducing ValveSeries VM

Catalogue HY11-2500/UK

4

Dimensions

NG10

FPM

BK389 4 x M10x50 65Nm SK-VB/VM-A10VDIN 912 12.9

Surface finish

Mounting pattern DIN 24340-D10-1

Page 76: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-76

VM.PM6.5 RH

Direct Operated Pressure Reducing ValveSeries VM

Catalogue HY11-2500/UK

4

Notes

Page 77: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-77

DWL-DWK UK.PM6.5 RH

Pressure Reducing ValveSeries DWL and DWK

Catalogue HY11-2500/UK

4

Port size DIN NG10 NG25 NG32

CETOP 5 8 10

Mounting pattern DIN 24340-D10-32ISO 5781 and ISO 6264

Operating pressure [bar] Pressure ports A, B = 350Tank port Y = not pressurised

Adjustment range [bar] 0 up to 350

Nominal flow Q [l/min]* 150 250 350

Mounting position as desired

Weight [kg] 4.8 5.9 8.9

Technical data

Characteristics

DWK series with bypass check valve.

Series DWL

Pressure reducing valves of the DWL/DWK series main-tain a constant pressure on the secondary side (port A)at a set value.

To achieve accurate response the valve is fitted with asliding spool. A flow control valve is located in the spoolto maintain a constant pilot flow.

Characteristic curve

The drawings only show the adjustment type code 5 =turning knob with ratchet.

Graphic display and functionThe symbol shown in the characteristics corresponds tothe DIN/ISO representation for pressure reducing valveswith open neutral position, i.e. the valve goes into thecontrol setting only when the set secondary pressure isreached. The Parker valves of the series DWL and DWKare, in contrast, closed in the neutral position. The ad-vantage here is that the secondary build-up pressure isachieved more softly. Pressure peaks or pressure wavesdo not reach the actuator.

If the pressure on the secondary side A increases abovethe set pressure on the valve, the excess oil is directedthrough the pilot valve to reduce pressure. The pilot oilflow is directed to tank via port Y.

* The nominal flow volume is a recommended value for projecting,and is not the application limit for the valve which is dependent onthe individual permitted pressure increase value.

Page 78: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-78

DWL-DWK UK.PM6.5 RH

Pressure Reducing ValveSeries DWL and DWK

Catalogue HY11-2500/UK

4

Code Seal

omit NBR

V FPM

Seal Mechanicallyadjustable pressure

reducing valve

Variation

DW

Nominalsize

Code Variation

L Without bypasscheck valve

K With bypasscheck valve

Seriesletter

C

Code Adjustment

Hexagon socket2 screw with

lock nut

61 Turning knobwith E10 lock

Adjustment Pressurerange

Code Pressurerange

B 70 barE 175 barG 250 barK 350 bar

Series

52

Code Nominalsize

P15 NG10P20 NG25P40 NG32

Ordering Code / Function Representation

*)DWL without bypass check valve

Symbol DWKFunction diagram DWK

Adjustment styles

2. Hexagon socket with lock nut

61. Turning knob with E10 lock

MountingSize manifold

DIN 912 12.9 NBR FPM

NG10 SPP3M6B910 BK389 4xM10x50 65Nm SK-DWLC 5P15 SK-DWLC 5P15V

NG 25 SPP6M8B910 BK485 4xM10x45 65Nm SK-DWLC 5P20 SK-DWLC 5P20V

NG 32 SPP10M12B910 BK390 6xM10x50 65Nm SK-DWLC 5P40 SK-DWLC 5P40V

Page 79: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-79

DWL-DWK UK.PM6.5 RH

Pressure Reducing ValveSeries DWL and DWK

Catalogue HY11-2500/UK

4

DWL-DWK NG25

Dimensions

DWL-DWK NG10

Page 80: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-80

DWL-DWK UK.PM6.5 RH

Pressure Reducing ValveSeries DWL and DWK

Catalogue HY11-2500/UK

4

Dimensions

Mounting pattern DIN24340-D10-32

DWL-DWK NG32

NG d1 d2 d3 d4 b1 b2 m1 m2 m3max ±0.2 H12 min. max. ±0.2 ±0.2 ±0.2

10 14.7 M10 4.8 7.5 84 92 42.9 35.7 31.8

25 23.4 M10 4.8 7.5 97 105 60.3 49.2 44.5

32 32 M10 4.8 7.5 114 10 84.1 67.5 62.7

NG m4 m5 m6 m7 m8 n1 n2 n3 n4±0.2 ±0.2 ±0.2 ±0.2 min. ±0.2 ±0.2 ±0.2 ±0.2

10 21.4 - 21.4 7.1 61 66.7 58.7 33.3 7.9

25 39.7 - 20.6 11.1 78 79.4 73 39.7 6.4

32 59.6 42.1 24.6 16.7 102 96.8 92.9 48.8 4

Page 81: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-81

VMY-LN.PM6.5 RH

Pilot-Operated Proportional Pressure ValvesSeries VMY*L06N

Catalogue HY11-2500/UK

4

Characteristics / Ordering Code

VMY*06

The valve consists of the main stage with valve spoolsand the pilot stage with the proportional solenoids. Thedesired pressure can be variably set corresponding tothe command signal specified on the amplifier. The pro-portional solenoid converts the current of the amplifierinto force on the valve poppet of the pilot stage.

In the pilot stage, there is a flow limiter which suppliesthe pilot valve with pressure-independent pilot oil flowfrom the pressure port P. The pilot oil is returned via theY connection on the pilot valve to the tank.

The proportional pressure reducing valves of the seriesVMY*L*N allow the variable adjustment of the reducedpressure from 0 bar up to pmax. Typical applications arepressure systems, test equipment, or counterweight sys-tems. The electrical control of the valve takes place us-ing the digital amplifier module PCD00A-400. Use inclosed pressure control circuits is also possible. The valveis distinguished by its constancy.

FunctionWith the proportional solenoids de-energised a springforces the main spool into the neutral position. The portA is connected to port T. Thus a reduced pressure of 0bar is achieved for a de-energised valve. With the limita-tion the back pressure in the external drain pipe and/ortank pressure is the minimum available pressure. Thepressure present in the P line delivers the pilot oil to thepilot stage via a flow control valve.

When the proportional solenoid is energised, the pilotpressure is increased in the pilot pressure area, and themain spool moves against the spring until the connec-tion P-A opens. The regulation of the reduced pressureon connection A takes place by the constant comparisonof the actual pressure and the reference pressure of thepilot stage.

CodeMax. setting

range

064 64bar100 100bar160 160bar210 210bar315 315bar

Nominalsize

NG06

Reducingvalve

Max.settingrange

Linearsolenoid

LV Y

Highpressurechannel

06

FPMseal

Pressureadjustmentpmin = 0 baris possible

N

Designseries

M P

Ordering code

V

Page 82: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-82

VMY-LN.PM6.5 RH

Pilot-Operated Proportional Pressure ValvesSeries VMY*L06N

Catalogue HY11-2500/UK

4

Technical Data

GeneralDesign type Proportional reducing valve

Nominal size [DIN/CETOP] 6 / 03

Interface DIN 24340-C6-1

Actuation Proportional solenoid

Mounting position as desired

Environmental temperature [°C] -20 ... +70

Weight [kg] 2.8

HydraulicsOperating pressure [bar] Ports P, A and B 315; Port T depressurized

Adjustment range [bar] up to 64, 100, 160, 210, 315

Nominal flow [l/min] 40

Pressure medium Hydraulic oil as per DIN 51 524 ... 535

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 20 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +70

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Linearity [%] see characteristic pressure curves

Repeatability [%] <±2

Hysteresis [%] ±1.5 to pmax

Response time [ms] <150

Manufacturing tolerance [%] ±5 to pmax

ElectricalDuty cycle [%] 100 ED

Protection class IP54 at DIN 40050 (plugged and mounted)

Nominal voltage [V] 24

Max. current [mA] 800

Ambient temperature [°C] -20...+70

Coil resistance [Ohm] 21 at 20°C

Plug connectors 2pole + PE / connector EN 175301-803 / cableØ 8...10mm

Power amplifier PCD00A-400

Page 83: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-83

VMY-LN.PM6.5 RH

Pilot-Operated Proportional Pressure ValvesSeries VMY*L06N

Catalogue HY11-2500/UK

4

Characteristic pressure lines p = f (Uset)Setting range max. 210 barSetting range max. 64 bar

Characteristic Curves

Page 84: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-84

VMY-LN.PM6.5 RH

Pilot-Operated Proportional Pressure ValvesSeries VMY*L06N

Catalogue HY11-2500/UK

4

Characteristic Curves

Setting range max. 64 bar

p/Q characteristicsmeasured at t = 50°C and ν 0 35 mm²/s

Setting range max. 160 bar

Setting range max. 210 bar

Setting range max. 100 bar

Page 85: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-85

VMY-LN.PM6.5 RH

Pilot-Operated Proportional Pressure ValvesSeries VMY*L06N

Catalogue HY11-2500/UK

4

Characteristic Curves

Setting range max. 315 bar

p/Q characteristicsmeasured at t = 50°C and ν 0 35 mm²/s

Step response(typical characteristic curve)

Page 86: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-86

VMY-LN.PM6.5 RH

Pilot-Operated Proportional Pressure ValvesSeries VMY*L06N

Catalogue HY11-2500/UK

4

Dimensions

Dimensions

Mounting pattern DIN 24340-C6-1

The connection Bis to be lockedonto the subplatefor standard appli-cations.

FPM

BK375 M5 x 30 7.5 Nm SK-VMY-L06-VDIN 912 12.9

Surface finish

Page 87: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-87

VMY-L.PM6.5 RH

Pilot-Operated Proportional Reducing ValveSeries VMY*L10

Catalogue HY11-2500/UK

4

The pressure reducing valve consists of the main stagewith valve spools and the pilot stage. There is a flow limiterin the pilot stage. The pilot oil is provided internally fromthe P port. The drain is returned externally.

Typical applications are pressure systems, test equip-ment, or counterweight systems. The use in closed pres-sure control circuits is also possible.

FunctionThe valve spool is designed so that the connection B->Ais open in the neutral position and is closed in the work-ing position. The flow limiter provides a constant pilot oilflow from the B port to the pilot spool.

Characteristics / Ordering Code

Code Max. setting range

064 64bar100 100bar160 160bar210 210bar315 315bar

Nominal sizeNG10

Pressurereducing

valve

Max.settingrange

Linearsolenoid

L

Seal Designseries

Code Seal

N NBR

V FPM

V Y

Pilot oilfrom

primaryport

Ordering code

M 10 P

Page 88: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-88

VMY-L.PM6.5 RH

Pilot-Operated Proportional Reducing ValveSeries VMY*L10

Catalogue HY11-2500/UK

4

Technical Data

GeneralDesign type Proportional reducing valve

Nominal size [DIN/CETOP] 10 / 05

Interface DIN 24340-D10-2

Actuation Proportional solenoid

Mounting position as desired

Ambient temperature [°C] -20 ... +70

Weight [kg] 5

HydraulicsOperating pressure [bar] Ports A, B and X 315; Port Y depressurized

Adjustment range [bar] up to 64, 100, 160, 210, 315

Nominal flow [l/min] 160

Pressure medium Hydraulic oil as per DIN 51 524 ... 525

Viscosity, recommended [mm²/s] 30 ... 50maximum [mm²/s] 20 ... 380

Pressure medium temperaturerecommended [°C] 30 ... 50maximum [°C] -20 ... +70

Permitted contamination NAS 1638 class 9, to achieve with β10 = 75

Linearity [%] ±3.5 at > 15% pnom.

Repeatability [%] <±2

Hysteresis [%] ±1.5 to pmax

Response time [ms] <200

Manufacturing tolerance [%] ±5 to pmax

Electrical (proportional solenoid)

Duty cycle [%] 100 ED

Protection class IP54 at DIN 40050 (plugged and mounted)

Nominal voltage [V] 24

Max. current [mA] 800

Ambient temperature [°C] -20...+70

Coil resistance [Ohm] 21 at 20°C

Plug connectors 2pole + PE / connector EN 175301-803 / cableØ 8...10mm

Power amplifier PCD00A-400

Page 89: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-89

VMY-L.PM6.5 RH

Pilot-Operated Proportional Reducing ValveSeries VMY*L10

Catalogue HY11-2500/UK

4

Characteristic Curves

Setting range, max. 64 bar

p/Q characteristics VMY NG10for pilot oil supply from the high pressure channel P, measured at t = 50°C and ν = 35 mm²/s

Setting range, max. 100 bar

Setting range, max. 210 bar

Setting range, max. 160 bar

Page 90: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-90

VMY-L.PM6.5 RH

Pilot-Operated Proportional Reducing ValveSeries VMY*L10

Catalogue HY11-2500/UK

4

Dimensions

FPM

BK389 4 x M10x50 65 Nm SK-VB/VM-A10VDIN 912 12.9

Surface finish

Mounting pattern DIN 24340-D10-1

Page 91: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-91

DWE-DWU.PM6.5 RH

Proportional Pressure Reducing ValvesSeries DWE and DWU

Catalogue HY11-2500/UK

4

Technical data

Characteristics

Proportional pressure reducing valves of the DWE/DWUseries are in principle the same as the DWL/DWK se-ries, except that they are adjusted by a proportional so-lenoid.

The control command signals are provided by externalelectronic modules.

* The nominal flow volume is a recommended value for projecting, and is not the application limit for the valve which is dependent on theindividual permitted pressure increase value.

Series DWU with bypass check valveSeries DWE

Mounting sizes DIN NG10 NG25 NG32

CETOP 5 8 10

Interface DIN 24340 Form D

ISO 5781 and ISO 6264

Working pressure [bar] Pressure port A, B=350; Tank connection Y = not pressurised

Adjustment ranges [bar] 0 to 350

Nominal flow volume Q * [l/min] 150 250 350

Mounting position as desired

Weight [kg] 5.2 6.3 9.3

DWE DWU

Page 92: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-92

DWE-DWU.PM6.5 RH

Proportional Pressure Reducing ValvesSeries DWE and DWU

Catalogue HY11-2500/UK

4

Nominal MountingSize size manifold

DIN 912 12.9 NBR FPM

P15 NG10 SPP3M6B910 BK389 4xM10x50 65Nm SK-DWEE 5P15 SK-DWLC 5P15V

P20 NG 25 SPP6M8B910 BK485 4xM10x45 65Nm SK-DWEE 5P20 SK-DWLC 5P 20V

P40 NG 32 SPP10M12B910 BK390 6xM10x50 65Nm SK-DWEE 5P40 SK-DWLC 5P 40V

Code Seal

omit NBR

V FPM

Seal ProportionalPressure Reduc-

ing Valve

Design

DW

Valvesize

Code Design

E Without bypasscheck valve

U With bypasscheck valve

Serialletter

E

Pressurerange

Code Pressure range

C 105bar

E 175bar

G 250bar

K 350bar

Series

527

Code Nominal size

P15 NG10

P20 NG25

P40 NG32

Ordering Code

Code Option

omit Standard

Quick pressureUunloading

Option Solenoid16V, 1.3A;connectorEN 175301-

803

LA

Page 93: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-93

DWE-DWU.PM6.5 RH

Proportional Pressure Reducing ValvesSeries DWE and DWU

Catalogue HY11-2500/UK

4

Performance curves

Function diagram DWU

Symbol DWU

*) DWE without bypass check valve

Characteristics

Electronic modules

101 102ED 00

104 105

PCD 400

For further specifications, see chapter 10, Electronics.

Electronic

control card

optional

Page 94: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-94

DWE-DWU.PM6.5 RH

Proportional Pressure Reducing ValvesSeries DWE and DWU

Catalogue HY11-2500/UK

4

Dimensions

DWE / DWU NG10

DWE / DWU NG25

Page 95: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-95

DWE-DWU.PM6.5 RH

Proportional Pressure Reducing ValvesSeries DWE and DWU

Catalogue HY11-2500/UK

4

DWE / DWU NG32

Dimensions

Page 96: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-96

DWE-DWU.PM6.5 RH

Proportional Pressure Reducing ValvesSeries DWE and DWU

Catalogue HY11-2500/UK

4

Mounting pattern

Nominal size d1 d2 d3 d4 b1 b2 m1 m2 m3 m4 m5 m6 m7 m8 n1 n2 n3 n4max ±0.2 H12 min. max. ±0.2 ±0.2 ±0.2 ±0.2 ±0.2 ±0.2 ±0.2 min. ±0.2 ±0.2 ±0.2 ±0.2

10 14.7 M10 4.8 7.5 84 92 42.9 35.7 31.8 21.4 - 21.4 7.1 61 66.7 58.7 33.3 7.9

25 23.4 M10 4.8 7.5 97 105 60.3 49.2 44.5 39.7 - 20.6 11.1 78 79.4 73 39.7 6.4

32 32 M10 4.8 7.5 114 10 84.1 67.5 62.7 59.6 42.1 24.6 16.7 102 96.8 92.9 48.8 4

Dimensions

Page 97: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-97

PE-PC.PM6.5 RH

Proportional Pressure Reducing ValvesSeries PE and PC

Catalogue HY11-2500/UK

4

Characteristics

PE/PC10M

The proportional pressure reducing valves of the PE/PCseries have a proportional solenoid operated pilot stageand sliding spool main stage. The hydraulic function is inprinciple the same as the DWL/DWK series.

The power supply voltage and input command signalsare connected via a single seven-pin electrical plug con-nector. Input command signals can be in the range 0 to10V or 0 to 20mA, selected in the valve ordering code.Ramp times for increasing and decreasing pressure canbe independently set on two potentiometers.

MIN and MAX potentiometers allow the setting of theminimum pressure and the maximum pressure. Thesecan be adjusted to scale the set pressure range to corre-spond to the full range of the command input signal.

PE

PC

Page 98: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-98

PE-PC.PM6.5 RH

Proportional Pressure Reducing ValvesSeries PE and PC

Catalogue HY11-2500/UK

4

Code Nominal size

10 NG10

25 NG25

32 NG32

Ordering Code

MountingSize manifold

DIN 912 12.9 NBR FPM

NG10 SPP3M6B910 BK389 4xM12x70 65Nm SK-PE10MM10 SK-PE10MV10NG25 SPP6M8B910 BK485 4xM16x110 65Nm SK-PE25MM10 SK-PE25MV10NG32 SPP10M12B910 BK390 4xM10x50 65Nm SK-PE32MM10 SK-PE32MV10

Code Valve type

ProportionalPressure

PE Reducing Valvewithout

check valve

ProportionalPressure

PC Reducing Valvewith check

valve

Valve type

Nominalsize

Manifolddesign

Pressurerange

Internalsupply,external

drain

Code Pressure range

10 105

17 175

25 250

35 350

Spring1bar

Seal

Code Seal

N NBR

V FPM

Intergr.electronics

T

Electr.attachments

Normallyclosed

9

Code Electr. design

Voltage input

F0 to +10V

(standard) withreference output

+10V

GCurrent input

0 to 20mA

Designseries

Options

Code Options

omit Standard

Quick pressureUunloading

Electr.design

M 1 R 0

Page 99: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-99

PE-PC.PM6.5 RH

Proportional Pressure Reducing ValvesSeries PE and PC

Catalogue HY11-2500/UK

4

Characteristics

Technical data

Mounting sizes DIN NG10 NG25 NG32

CETOP 5 8 10

Mounting pattern DIN 24340 Form D

ISO 5781 and ISO 6264

Working pressure [bar] Pressure port A, B = 350; Tank connection Y = not pressurised

Adjustment ranges [bar] 0 to 350

Nominal flow volume* Q [l/min] 150 250 350

Mounting position as desired

Weight [kg] 5.5 6.5 11.0

Characteristic curves

* The nominal flow volume is a recommended value for projecting, and is not the application limit for the valve which is dependent on theindividual permitted pressure increase value.

Page 100: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-100

PE-PC.PM6.5 RH

Proportional Pressure Reducing ValvesSeries PE and PC

Catalogue HY11-2500/UK

4

Dimensions

PE/PC10M

PE/PC25M

Page 101: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-101

PE-PC.PM6.5 RH

Proportional Pressure Reducing ValvesSeries PE and PC

Catalogue HY11-2500/UK

4

Dimensions

PE/PC32M

Mounting pattern

NG d1 d2 d3 d4 b1 b2 m1 m2 m3max ±0.2 H12 min. max. ±0.2 ±0.2 ±0.2

10 14.7 M10 4.8 7.5 84 92 42.9 35.7 31.8

25 23.4 M10 4.8 7.5 97 105 60.3 49.2 44.5

32 32 M10 4.8 7.5 114 10 84.1 67.5 62.7

NG m4 m5 m6 m7 m8 n1 n2 n3 n4±0.2 ±0.2 ±0.2 ±0.2 min. ±0.2 ±0.2 ±0.2 ±0.2

10 21.4 - 21.4 7.1 61 66.7 58.7 33.3 7.9

25 39.7 - 20.6 11.1 78 79.4 73 39.7 6.4

32 59.6 42.1 24.6 16.7 102 96.8 92.9 48.8 4

Page 102: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-102

PE-PC.PM6.5 RH

Proportional Pressure Reducing ValvesSeries PE and PC

Catalogue HY11-2500/UK

4

Block diagram of the electronics

Signal / pressure curves Connector wiring diagram

Electronics

A deviation of ±5% of the linear performance curve ispossible depending on valve design.

Supply voltage range [V] 14.5 ... 30

Ripple in the supply voltage [%] max. 5

Current consumption[A] max. 2.8

Input range Voltage input 0 ... +10V / 10kOhm

Current input 0 ... +20mA / 500Ohm

Reference output +10V / max. 10mA

Adjustment range of the ramp time [s] 0 ... 5

Ambient temperature range [°C] -40 ... +70

Installation cross-section min. 1.0mm² shielded

Cable length [m] max. 50

Protection class IP54

Order number for attachments:

7 pole plug (main connection) 5004072

Electronic characteristics

Page 103: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-103

Accessories 4.PM6.5 RH

Catalogue HY11-2500/UK

4

Pressure ValvesAccessories

Description Threaded cable Body colour Figures Order No.joint Coding Switching

Plug DIN 43650, design type AF, protection class IP 65 PG 9 black, B Fig. 1 5001710Voltages up to 250 V grey, A 5001711

PG11 black, B Fig. 1 5001716*grey, A 5001717*

Plug with LED insert 24 V PG11 black, B Fig.1 and 5001571grey, A Fig. 3 5001572

Plug with LED insert 110 V PG11 black, B Fig.1 and 5001573grey, A Fig. 4 5001574

Plug with LED insert 220 V PG11 black, B Fig.1 and 5001575grey, A Fig. 4 5001576

Plug with LED insert 24V and PG11 black, B Fig.1 and 5001708suppressing circuitry grey, A Fig. 5 5001709

Plug with rectifier use rectifier with 4 silicon diodes PG11 black, B Fig.1 and 5001737in bridge circuit Varistor n alternating current side to grey, A Fig. 6 5001738protect the diodes against power peaks

Plug with pull relief PG11 black, B Fig. 2 5001723and translucent cover grey, A 5001724

Application with bridge rectifier — — Fig. 2 and 5001727suitable for 5001723 and 5001724 Fig. 7

Application with bridge rectifier and lamp — — Fig. 2 and 5001734suitable for 5001723 and 5001724 Fig. 8

* If not ordered otherwise, valves with code P are supplied with these connectors.

Plugs

Page 104: Catalogue HY11-2500/UK Chapter 4: Contents Pressure …cairohydraulic.com/products/1- Parker New/Parker Industrial... · Hydraulics Working pressure [bar] ... Catalogue HY11-2500/UK

4-104

Accessories 4.PM6.5 RH

Catalogue HY11-2500/UK

4

Pressure ValvesNotes