96
2-1 Catalogue HY11-2500/UK 2 D1SE Seated valves 2- 3 Spool valves, electrically operated D1VW Standard, 3-chamber-valve 2-7 D1VW 8 Watt, 3-chamber-valve 2-15 D1VW Soft shift, 3-chamber-valve 2-21 D1DW 5-chamber-valve 2-27 D1VW, D1DW Position control, 3-/5-chamber-valve 2-32 D3W Standard, 3-chamber-valve 2-37 D3DW 5-chamber-valve 2-43 D3W, D3DW Position control, 3-/5-chamber-valve 2-48 Spool valves, hydraulically operated D1VP 2-53 D3DP D4P 2-57 D9P D11P Spool valves, manually / mechanically operated D1VC, D1VD 2-65 D1DL 2-69 D3DL D4L 2-73 D9L Spool valves, electrically operated D31DW 2-79 D41VW D81/91VW D111VW Accessories Plugs EN 175301-803 (DIN 43650) 2-90 Plug M12x1, conduit boxes 2-91 Actuator kits (solenoids/Coils) 2-92 O-rings and seal kits 2-93 Slip-in orifices 2-94 Mounting patterns 2-95 Chapter 2: Directional Control Valves Contents Series Description Direct Pilot Page operated operated Size NG 06 10 16 25 32 06 10 16 25 32 Size ISO/CETOP 3 5 7 8 10 3 5 7 8 10 If you are interested in fast delivery, please fol- low this hint in our ordering codes when choos- ing your individual product:

Catalogue HY11-2500/UK Chapter 2: Contents Directional ... · 2-2 D1SE_GB.PM6.5MM Hydraulics 3/2-Way Seated Type Directional Control Valve Series D1SE Catalogue HY11-2500/UK 2 Notes

  • Upload
    buidat

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

2-1

Catalogue HY11-2500/UK

2

D1SE Seated valves • 2- 3

Spool valves, electrically operated

D1VW Standard, 3-chamber-valve • 2-7

D1VW 8 Watt, 3-chamber-valve • 2-15

D1VW Soft shift, 3-chamber-valve • 2-21

D1DW 5-chamber-valve • 2-27

D1VW, D1DW Position control, 3-/5-chamber-valve • 2-32

D3W Standard, 3-chamber-valve • 2-37

D3DW 5-chamber-valve • 2-43

D3W, D3DW Position control, 3-/5-chamber-valve • 2-48

Spool valves, hydraulically operated

D1VP • 2-53

D3DP •D4P • 2-57

D9P •D11P •

Spool valves, manually / mechanically operated

D1VC, D1VD • 2-65

D1DL • 2-69

D3DL •D4L • 2-73

D9L •

Spool valves, electrically operated

D31DW • 2-79

D41VW •D81/91VW •D111VW •

Accessories Plugs EN 175301-803 (DIN 43650) 2-90Plug M12x1, conduit boxes 2-91Actuator kits (solenoids/Coils) 2-92O-rings and seal kits 2-93Slip-in orifices 2-94Mounting patterns 2-95

Chapter 2:Directional Control ValvesContents

Series Description Direct Pilot Pageoperated operated

Size NG 06 10 16 25 32 06 10 16 25 32Size ISO/CETOP 3 5 7 8 10 3 5 7 8 10

If you are interested in fast delivery, please fol-low this hint in our ordering codes when choos-ing your individual product:

2-2

D1SE_GB.PM6.5MM

Hydraulics

3/2-Way Seated Type Directional Control ValveSeries D1SE

Catalogue HY11-2500/UK

2

Notes

2-3

2

D1SE_GB.PM6.5MM

Hydraulics

3/2-Way Seated Type Directional Control ValveSeries D1SE

Catalogue HY11-2500/UK

2

Characteristics

GeneralThe directional valve type D1SE is equipped with a wetpin armature solenoid, drain free tapered poppet valveand compatible with the standards DIN NG06, CETOP03, and NFPA D03. Due to the 3/2 way design, port A iseither connected with P or discharged in the tank. Theneutral position (solenoid not activated) is takenautomatically by a return spring. This position remainsuntil the solenoid is energized.

The valve poppet including activation lever and arma-ture of the solenoid are located in the pressurised oilchamber of connection T. The valve poppet is designedsuch that there can be no differential area in its axialoperational direction (opening, closing). Thus it isstatically pressure-balanced so that the valve can beswitched in both flow directions even under pressure.

The unit has an all-steel design, the important functionalinner parts are hardened, the poppet and seat aregrinded.

Characteristics

GeneralDesign Directional poppet valve

Nominal size DIN NG6 / CETOP 03 / NFPA D03

Interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03

Mounting position unrestricted

Environmental temperature - 40°C...+ 80°C, observe permissible duty cycle

Weight 0.8 kg

HydraulicsOperating liquid Hydraulic oil, in accordance with DIN 51524 / 51525

Pressure fluid temperature -25°C to + 70°C

Viscosity range ν 4 to 1500 mm2/s (4 to 1500 cSt)

Working pressure: P, A and T 350 bar

Max. flow 20 l/min (at ∆p 10 bar)Max. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle see diagramProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)Surface temperature approx. 98°C, at 20°C ambient temperature

Voltages (± 10%)

DC voltage Code Power Current

12 V K 23.4 W 1.95 A24 V J 26.4 W 1.1 A98 V U* 24.3 W 0.25 A205 V G* 26.6 W 0.13 A

Response times (recommended value)Energized approx. 50 msDeenergized approx. 60 msMax. switching frequency 2000 switchings/hourSolenoid connection options Connector as per EN 175301-803

* For a silicon bridge rectifier, set up apart from unit for connecting to a 50 or 60 Hz power supply, 110 V~(98=) or 230V~ (205V=).

2-4

D1SE_GB.PM6.5MM

Hydraulics

3/2-Way Seated Type Directional Control ValveSeries D1SE

Catalogue HY11-2500/UK

2

Ordering Code

D S E1

Code

K

J

U*

G*

Voltage

12V=

24V=

98V=

205V=

Code Material

NBR

FPM

N

V

Spool typeCode

30

83 * For alternating currentuse plug with rectifier.

B

Directionalcontrolvalve

Seatvalve

Wet pinarmaturesolenoid,flanged

SizeDIN NG06CETOP 03NPPA D03

DesignSeries

Not requiredfor ordering

Style Solenoidvoltage

Seals Solenoidconnection

without plug

Spool

A

P T

Voltage

12V=

205V=

24V=

98V=

Ordering code

7329700 - 12V

7329700 - 205V

7329700 - 24V

7329700 - 98V

Coils for repair

W

2-5

2

D1SE_GB.PM6.5MM

Hydraulics

3/2-Way Seated Type Directional Control ValveSeries D1SE

Catalogue HY11-2500/UK

2

Characteristic Curves / Dimensions

Dimensions

Performance curve ∆∆∆∆∆p-Q Duty cycle versus ambient temperature

Subplates and manifolds see chapter 8.

BK375 4x M5x30 6.8 Nm ± 15% NBR: SK-D1SE-70DIN 912 12.9 FPM: SK-D1SE-V70

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-6

D1VW-St_GB.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Notes

2-7

2

Hydraulics

D1VW-St_GB.PM6.5MM

Catalogue HY11-2500/UK

2

Characteristics

GeneralDesign Directional spool valveSize DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight: Valve with 1 solenoid 1.5 kg

Valve with 2 solenoids 2.1 kg

HydraulicsFluids Hydraulic oil, in accordance with DIN 51524 / 51525Fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T DC: 210 bar AC: Standard: 105 bar Code “H”: 210 barLeakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path, depending on spoolMax. flow 80 l/minMax. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle 100% ED; CAUTION: Coil temperature up to 150º C possible

Protection class IP 65 in accordance with DIN 40050 (plugged and mounted)Voltages (±10%) Holding in Rush

DC voltage Code Power Current Power Current

12 V K 30 W 2.5 A - -24 V J 30 W 1.25 A - -98 V U 30 W 0.31 A - -205 V G 30 W 0.15 A - -AC voltage110V 50 Hz / 120V 60 Hz Y 64 VA / 59 VA 0.58 A / 0.49 A 231 VA / 240 VA 2.1 A / 2.0 A230V 50 Hz / 240 V 60 Hz T 68 VA / 62 VA 0.31 A / 0.26 A 231 VA / 240 VA 1.05 A / 1.0 AResponse times (at 32 l/min and 250 bar) DC voltage AC voltageEnergized / deenergized 32 ms / 40 ms 13 ms / 20 ms

Max. switching frequency 15000 switchings/hour

Solenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.Conduit box with flying leads, optional with Brad Harrison plug.

Directional Control ValvesSeries D1VWCharacteristics

The D1VW is a 3 chamber-, electrically controlled 4/3or 4/2 way directional control valve. It is activated di-rectly by solenoids with screwed in wet pin armature.The coils can be exchanged for various input voltages,however, a change between alternating (AC) and directcurrent (DC) is not possible.

2-8

D1VW-St_GB.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VWOrdering Code

WD V

Directionalcontrolvalve

Wet pinarmaturesolenoid,threadedin tube

3 chamber valve

Seals

Code

N NBR

V FPM

Material

Style

Spool type

1

SizeDIN NG 6CETOP 3

NFPA D03

2-9

2

Hydraulics

D1VW-St_GB.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW

Solenoidoptions

Solenoidconnection

Designseries

Not requiredfor ordering

Solenoidvoltage

Accessories

Further spool types, styles, voltages, accessories andcombinations on request.

Code Voltage

110V 50Hz120V 60Hz

230V 50Hz240V 60Hz

Y

T

2) For alternating currentuse plug with rectifier,and order with solenoidconnection code W.Please order rectifierplug separately.

Code Description

2) Please order plug separately.See chapter 2. accessories.

Conduit box withflying leads

C

Connector asper EN 175301-803,

without plugW 2)

12V=

24V=

98V=

205V=

K

J

U 2)

G 2)

Code Description

omit Standard valvewithout

accessories

Brad Harrisonconnector male plug

in a conduit box6

Signal light andterminal strip

in a conduit box5

Code Description

Standard solenoidwithout options

omit

withoutmanualoverride

T

Solenoid tubetank pressure

210bar(only for AC)

H

Splash proofW

Option 5 and 6combined

56

2-10

D1VW-St_GB.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW - Explosion proofOrdering Code

WD V

Directionalcontrolvalve Wet pin

armaturesolenoid,threadedin tube

3 chambervalve

Solenoidoptions

Explosionproof

EEx me II

SolenoidconnectionExplosion

proofwith cable

glands

Designseries

Not requiredfor ordering

Solenoidvoltage

Seals

Code

N NBR

V FPM

Seals

Style

Further spool types, styles, andcombinations on request.

1

SizeDIN NG 6CETOP 3

NFPA D03

Code Voltage

110V 50Hz

220V 50Hz

P

N

E E

24V=J

Spool type

2-11

2

Hydraulics

D1VW-St_GB.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VWFlow Curve

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values in thediagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Position "b" Position "a" Position "0"

Spool P ->A B->T P->B A->T P->A P->B A->T B->T P->T A->B

1 4 1 4 1 - - - - - -

2 5 2 5 2 4 4 1 1 6 1

3 4 1 4 2 - - 8 - - -

4 4 2 4 2 - - 7 7 - 9

5 4 1 5 1 9 - - - - -

6 5 1 5 1 9 9 - - - 9

7 5 2 4 1 - 5 - 1 7 -

10 4 - 4 - - - - - - -

11 4 2 4 2 - - 11 11 - -

14 2 5 1 4 5 - 1 - 7 -

15 4 2 4 1 - - - 8 - -

16 5 1 4 1 - - 9 - - -

20 5 1 5 1 - - - - - -

26 6 - 6 - - - - - - -

30 5 1 5 1 - - - - - -

81 10 10 10 10 - - - - - -

82 10 10 10 10 - - 1)* 1)* - -

P->B A->T P->A B->T P->A P->B A->T B->T P->T A-> B

8 2 2 2 2 - - - - 8 -

9 3 3 3 3 - - - - 9 -

Position "b" Position "a"

P->A P->B A->B P->B A->T

21 3 3 3 6 1

P->A B->T P->A P->B A->B

22 6 1 3 3 3

Flow curve

1)*Only for pressure compensation,no high flow possible

2-12

D1VW-St_GB.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VWShift Limits / Dimensions

The diagram below specifies the shift limits for valves withDC solenoids. Valves of style “F” and “M” may only beloaded at 70% of the value. The specifications apply to aviscosity of 35 mm2/s and equal flow at A and B port.

These values can be considerably lower than the repre-sented ones by unequal flow at A and B port. To avoidflow rates above the shift limits of the valve, a plug-inorifice can be inserted in the P port.

2-13

2

Hydraulics

D1VW-St_GB.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VWDimensions

Interface EN 175301-803: AC - Solenoid

B, E, F - style

C, D - style

H, K, M - style

Conduit box: (only C, D - style shown)

DC solenoid AC solenoid

DimensionsInterface EN 175301-803: DC - Solenoid

B, E, F - style

C, D - style

H, K, M - style

2-14

D1VW-St_GB.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

DimensionsDirectional Control ValvesSeries D1VW

Explosion proof:

B, E, F - style

C, D - style

H, K, M - style

BK375 4x M5x30 6.8 Nm ± 15% NBR: SK-D1VW-70DIN 912 12.9 FPM: SK-D1VW-V70

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-15

D1VW-8Watt._gbPM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW - 8 WattCharacteristics

The D1VW direct-controlled hydraulic valves are directlyoperated 4 way high-performance valves. They are avail-able with 2 or 3 positions. The valves are intended formanifold and subplate assembly, the interface corre-sponds to DIN 24340 A6. These valves are designed forindustrial hydraulic applications requiring high cycle rates,long service life, high efficiency, and low energy consump-tion.

The range of application of the 8 watt valve is the toolmachining industry, especially for transfer lines with manyvalves. Because of the low current consumption (< 0,5 A)and the design with M12x1 on the solenoids, a direct con-nection to PLC or a BUS-Knot is possible.Parker offers a concurring solution for the Decentralisedand Standardised Installation technique at machine tool(DESINA).

Characteristics

GeneralDesign Direct spool valveSize DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight: Valve with 1 solenoid 1.5 kg

Valve with 2 solenoids 2.1 kg

HydraulicsOperating liquid Hydraulic oil, in accordance with DIN 51524 / 51525Pressure fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path, depending on spoolMax. flow 45 l/minMax. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle 100% ED; CAUTION: Coil temperature up to 70º C possibleProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)

Voltages (± 10%)DC voltage Code Power Current

24 V J 8 W 0.33 A

Response times (at 25 l/min and 100 bar)Energized 80 - 120 msDeenergized 35 - 55 ms

Max. switching frequency 10,000 switchings/hour

Solenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.Plug M12x1

2-16

D1VW-8Watt_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Ordering CodeDirectional Control ValvesSeries D1VW - 8 Watt

WD V

Directionalcontrol

valve

Wet pinarmaturesolenoidthreadedin tube

3-chamber valve

Seals

Code

N NBR

V FPM

Material

Style

1

SizeDIN NG 6CETOP 3

NFPA D03

Spool type

1) only for spool 20.

2-17

D1VW-8Watt._gbPM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Solenoidoptions8-Watt

Solenoidconnection

Designseries

Not requiredfor ordering

Solenoidvoltage

24V=

Electricaloptions

Code Description

omit Standard valve

J5 Surge suppressor diode with light / LED,

max. voltagepeak 50V

(Only together withsolenoid

connection D)

Code Description

2) Please order plug separately.See page 2-90 accessories.

DM12x1 without plug(Only together with

Electrical options J5)

Connectoras per EN 175301-803,

without plugW 2)

Directional Control ValvesSeries D1VW - 8 Watt

Other spool types on request.To get a DESINA valve, order the combination: JDLJ5

J L

2-18

D1VW-8Watt_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values in thediagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Position "b" Position "a" Position "0"

Spool P ->A B->T P->B A->T P->A P->B A->T B->T P->T A->B

1 3 1 3 1 - - - - - -

2 2 1 2 1 2 2 1 1 2 1

3 5 1 5 1 - - 1 - - -

4 4 1 4 1 - - 1 1 - 8

5 4 2 5 2 7 - - - - -

6 2 4 2 4 7 7 - - - 7

7 6 1 4 2 - 2 - 1 4 -

10 6 - 5 - - - - - - -

11 6 2 6 2 - - 8 8 - -

14 4 2 6 1 2 - 1 - 4 -

15 5 1 5 1 - - - 1 - -

16 5 2 4 2 - - 7 - - -

20 5 3 5 3 - - - - - -

26 6 - 6 - - - - - - -

30 3 1 3 1 - - - - - -

P->B A->T P->A B->T P->A P->B A->T B->T P->T A-> B

8 6 6 6 6 - - - - 7 -

9 6 7 6 7 - - - - 3 -

Directional Control ValvesSeries D1VW - 8 WattFlow Curve

Flow curve

2-19

D1VW-8Watt._gbPM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW - 8 WattShift limit / Pin assignment

The diagram below specifies the shift limits for valveswith DC voltage solenoids. The specifications apply to aviscosity of 35 mm2/s and equal flow at A and B port.These values can be considerably lower than the repre-

sented ones by unequal flow at A and B port.To avoid flow rates above the shift limits of the valve, aplug-in orifice can be inserted in the P channel.

M12 pin assignment

0V

Signal (24 V)

DESINA - designPin 1 and 2 connected

Shift limit diagram

2-20

D1VW-8Watt_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW - 8 WattDimensions

Interface EN 175301-803: DC - Solenoid

B, E - style

C, D - style

H, K - style

DESINA (JDLJ5): DC - Solenoid

B, E - style

C, D - style

H, K - style

BK375 4x M5x30 6.8 Nm ± 15% NBR: SK-D1VW-70DIN 912 12.9 FPM: SK-D1VW-V70

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-21

2

Hydraulics

D1VW-Softshift_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Characteristics

GeneralDesign Directional spool valveSize DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight: Valve with 1 solenoid 1.5 kg

Valve with 2 solenoids 2.1 kg

HydraulicsFluids Hydraulic oil, in accordance with DIN 51524 / 51525Fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T Code “H”: 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path, depending on spoolMax. flow 80 l/minMax. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle 100% ED; CAUTION: Coil temperature up to 150º C possibleProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)

Voltages (± 10%)

DC voltage Code Power Current

12 V K 30 W 2.5 A24 V J 30 W 1.25 A98 V U 30 W 0.31 A205 V G 30 W 0.15 A

Response times see table reponse time

Solenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.

Directional Control ValvesSeries D1VW Soft ShiftCharacteristics

The D1VW soft shift is a 3 chamber-, electrically con-trolled 4/3 or 4/2 way directional control valve. It is acti-vated directly by solenoids with screwed in wet pin ar-mature.The soft shifting of the valve is achieved by damping theplunger in the tube with an orifice.

Orifice in plunger

2-22

D1VW-Softshift_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

WD V

Directionalcontrolvalve

Wet pinarmaturesolenoid,threadedin tube

3 chamber valve

Directional Control ValvesSeries D1VW Soft ShiftOrdering Code

Seals

Code

N NBR

V FPM

Material

Style

Spool type

1

SizeDIN NG 6CETOP 3

NFPA D03

2-23

2

Hydraulics

D1VW-Softshift_gb.PM6.5MM

Catalogue HY11-2500/UK

2

SolenoidconnectionConnector

as perEN 175301-803,without plugPlease order

plug separately.See Chapter 2accessories

Designseries

Not requiredfor ordering

Solenoidvoltage

Further spool types, styles and voltages on request.

Directional Control ValvesSeries D1VW Soft Shift

Code Voltage

U1)

G1)

12 V=

24 V=

98 V=

205 V=

K

J

S

Code Orificediameter

0.5 mm

0.75 mm

1.0 mm

XB072

XB073

XB074

Soft Shiftwith built in

orifice

Orificesize

1) For alternating currentuse plug with rectifier,and order with solenoidconnection code W.Please order rectifierplug separately.

W

Ordering Code

2-24

D1VW-Softshift_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW Soft ShiftFlow Curve

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values inthe diagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Position "b" Position "a" Position "0"

Spool P ->A B->T P->B A->T P->A P->B A->T B->T P->T A->B

1 4 1 4 1 - - - - - -

2 5 2 5 2 4 4 1 1 6 1

3 4 1 4 2 - - 8 - - -

4 4 2 4 2 - - 7 7 - 9

5 4 1 5 1 9 - - - - -

6 5 1 5 1 9 9 - - - 9

7 5 2 4 1 - 5 - 1 7 -

10 4 - 4 - - - - - - -

11 4 2 4 2 - - 11 11 - -

14 2 5 1 4 5 - 1 - 7 -

15 4 2 4 1 - - - 8 - -

16 5 1 4 1 - - 9 - - -

20 5 1 5 1 - - - - - -

26 6 - 6 - - - - - - -

30 5 1 5 1 - - - - - -

81 10 10 10 10 - - - - - -

82 10 10 10 10 - - 1)* 1)* - -

P->B A->T P->A B->T P->A P->B A->T B->T P->T A-> B

8 2 2 2 2 - - - - 8 -

9 3 3 3 3 - - - - 9 -

Position "b" Position "a"

P->A P->B A->B P->B A->T

21 3 3 3 6 1

P->A B->T P->A P->B A->B

22 6 1 3 3 3

Flow curve

1)*Only for pressure compensation,no high flow possible

2-25

2

Hydraulics

D1VW-Softshift_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW Soft ShiftShift limits / Dimensions

The diagram below specifies the shift limits for valves withDC solenoids. Valves of design “F” and “M” may only beloaded at 70% of the value. 20% is to be subtracted forvalves with low wattage coils (solenoid option „F“). Thespecifications apply to a viscosity of 35 mm2/s and equal

flow at A and B port. These values can be considerablylower than the represented ones by unequal flow at Aand B port. To avoid flow rates above the shift limits ofthe valve, a plug-in orifice can be inserted in the P port.

DimensionsInterface EN 175301-803: DC - Solenoid

B, E, F - style

C, D - style

H, K, M - style

BK375 4x M5x30 6.8 Nm ± 15% NBR: SK-D1VW-70DIN 912 12.9 FPM: SK-D1VW-V70

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-26

D1VW-Softshift_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

For even softer shifting, the proportional spools 81 and82 can be used.

Directional Control ValvesSeries D1VW Soft ShiftResponse times

X-Number

XB072 0.50 200 ms 650 ms 700 ms 650 ms 175 ms 225 ms

XB073 0.75 125 ms 325 ms 550 ms 550 ms 100 ms 100 ms

XB074 1.00 100 ms 250 ms 500 ms 450 ms 75 ms 60 ms

3-positions: Spool Center Condition 2-positions

Orifice Closed Open

Size Energize Deenergize Energize Deenergize Energize Deenergize

The table below shows the response times of the soft shift valve.

Step response times were obtained under the following conditions: υ = 35 mm2/s at 50°C with the valve operating atnominal pressure and flow. Published response times are nominal and may vary with spool, flow, pressure and temperature.

The figure below shows the acceleration for orifice size 1.00 (XB074) which could be archived against avalve without soft shift.

2-27

D1DW_gb.PM6.5MM

Directional Control ValvesSeries D1DW 5 Chamber Valve

Hydraulics

Catalogue HY11-2500/UK

2

Characteristics

The D1DW is a 5 chamber-, electrically controlled 4/3 or4/2 way directional control valve. It is activated directlyby solenoids with screwed in wet pin armature.

Characteristics

GeneralDesign Directional spool valveSize DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight: Valve with 1 solenoid 1.5 kg

Valve with 2 solenoids 2.1 kg

HydraulicsFluids Hydraulic oil, in accordance with DIN 51524 / 51525Fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path, depending on spoolMax. flow 80 l/minMax. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle 100% ED; CAUTION: Coil temperature up to 150º C possibleProtection class IP 65 in accordance with DIN 40050 (plugged and mounted )

Voltages (± 10%)DC voltage Code Power Current

12 V K 30 W 2.5 A24 V J 30 W 1.25 A98 V U 30 W 0.31 A205 V G 30 W 0.15 A

Response times (at 32 l/min and 250 bar) DC voltageEnergized 32 msDeenergized 40 ms

Max. switching frequency 15.000 switchings/hourSolenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.

2-28

D1DW_gb.PM6.5MM

Hydraulics

Directional Control ValvesSeries D1DW 5 Chamber Valve

Catalogue HY11-2500/UK

2

WD D

Directionalcontrolvalve

Wet pinarmaturesolenoid,threadedin tube

5 chamber valve

Ordering Code

Seals

Code

N NBRV FPM

Material

Style

1

SizeDIN NG 6CETOP 3

NFPA D03

Spool type

Catalogue HY11-2500/UK

2-29

D1DW_gb.PM6.5MM

Directional Control ValvesSeries D1DW 5 Chamber Valve

Hydraulics

2

Solenoidoptions

SolenoidconnectionConnector

as perEN 175301-803,without plugPlease orderplug sepa-rately. SeeCapter 2

accessories

Designseries

Not requiredfor ordering

Solenoidvoltage

Further spool types, styles, voltages, accessories andcombinations on request.Explosion proof valves on request.

Code Voltage

1) For alternating current useplug with rectifier, and orderwith solenoid connectioncode W.Please order rectifier plugseperately.

Code Description

Standard solenoidwithout options

omit

without manualoverrideT

SplashproofW

12V=

24V=

98V=

205V=

K

J

U 1)

G 1)

W

Ordering Code

2-30

D1DW_gb.PM6.5MM

Hydraulics

Directional Control ValvesSeries D1DW 5 Chamber Valve

Catalogue HY11-2500/UK

2

Flow Curve

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values in thediagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Position "b" Position "a" Position "0"

Spool P ->A B->T P->B A->T P->A P->B A->T B->T P->T A->B

1 4 1 4 1 - - - - - -

2 5 2 5 2 4 4 1 1 6 1

3 4 1 4 2 - - 8 - - -

4 4 2 4 2 - - 7 7 - 9

5 4 1 5 1 9 - - - - -

6 5 1 5 1 9 9 - - - 9

7 5 2 4 1 - 5 - 1 7 -

10 4 - 4 - - - - - - -

11 4 2 4 2 - - 11 11 - -

14 2 5 1 4 5 - 1 - 7 -

15 4 2 4 1 - - - 8 - -

16 5 1 4 1 - - 9 - - -

20 5 1 5 1 - - - - - -

26 6 - 6 - - - - - - -

30 5 1 5 1 - - - - - -

81 10 10 10 10 - - - - - -

82 10 10 10 10 - - 1)* 1)* - -

P->B A->T P->A B->T P->A P->B A->T B->T P->T A-> B

8 2 2 2 2 - - - - 8 -

9 3 3 3 3 - - - - 9 -

Position "b" Position "a"

P->A P->B A->B P->B A->T

21 3 3 3 6 1

P->A B->T P->A P->B A->B

22 6 1 3 3 3

Flow curve

1)*Only for pressure compensation,no high flow possible

2-31

D1DW_gb.PM6.5MM

Directional Control ValvesSeries D1DW 5 Chamber Valve

Hydraulics

Catalogue HY11-2500/UK

2

Shift limits / Dimensions

The diagram below specifies the shift limits for valves withDC solenoids. Valves of style “F” and “M” may only beloaded at 70% of the value. The specifications apply to aviscosity of 35 mm2/s and equal flow at A and B port.

These values can be considerably lower than the repre-sented ones by unequal flow at A and B port. To avoidflow rates above the shift limits of the valve, a plug-inorifice can be inserted in the P port.

DimensionsInterface EN 175301-803: DC - Solenoid

B, E, F - style

C, D - style

H, K, M - style

BK375 4x M5x30 6.8 Nm ± 15% NBR: SK-D1DW-70DIN 912 12.9 FPM: SK-D1DW-V70

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-32

D1VW_DW-Pos_gbPM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Characteristics

GeneralDesign Directional spool valveNominal size DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature 0°C...+50°CWeight: Valve with 1 solenoid 1.8 kg

HydraulicsOperating liquid Hydraulic oil, in accordance with DIN 51524 / 51525Pressure fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path, depending on spoolMax. flow 80 l/minMax. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electric system - solenoidDuty cycle 100% ED; CAUTION: Coil temperature up to 150° C possibleProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)

Voltages (± 10%) D1VW / D1DW

DC voltage Code Power Current

12 V K 30 W 2.5 A24 V J 30 W 1.25 A98 V U 30 W 0.31 A205 V G 30 W 0.15 A

Response times (at 32 l/min and 250 bar)

Energized / deenergized 32 ms / 40 ms

Max. switching frequency 15000 switchings/hourSolenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.

Directional Control ValvesSeries D1VW/D1DW with ind. pos. controlCharacteristics

The 4/2 directional valves operated directly by solenoidswith inductive position control are used as monitoringvalves. The start or end position can be monitored. Theposition control is only available for single solenoid valves.

The fail save position of the directional valve during powerfailure is the spring offset position.

AttentionThe switch may only be adjusted by the valve manu-facturer. The exchange of individual modules is notpermitted.

2-33

2

Hydraulics

D1VW_DW-Pos_gbPM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D1VW/D1DW with ind. pos. controlCharacteristics

Electrical characteristics - position control M12x1

Supply voltage 18 - 42 VRipple 10%Max. output current (ohmic load) 400 mA

IP65 as per DIN 40050Protection class (plugged and mounted)

Max. tolerance < 1200 A/mmagnetic ambient field strength at 50 Hz

Minimum distance > 100 mmto the next AC solenoid

Definitions:Start position monitored:The valve is deenergized. The inductive switch gives asignal at the moment (below 15% spool stroke) when thespool leaves the spring offset position.

Pin assignment

End position monitored:The inductive switch gives a signal before ending thestroke (above 85% spool stroke).

The switch can only be located opposite the solenoid for direct-controlled valves. This means, if the solenoid islocated on the A side of the valve, the switch can only take place on the B side.

1 Normally open2 + Supply

18...42V3 Normally closed4 0V5 Earth ground

M12 x 1-plug

2-34

D1VW_DW-Pos_gbPM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

WD

Directionalcontrolvalve

Wet pinarmaturesolenoidthreadedin tube

Ordering Code

Seals

Code

N NBR

V FPM

Seals

Style

Spool type

3) Only accessories code 11 or 804) Only accessories code 10 or 66

1

SizeDIN NG 6CETOP 3

NFPA D03

Directional Control ValvesSeries D1VW/D1DW with ind. pos. control

Code Design

V 3 chamber valve

D 5 chamber valve

1) Only available for styles "E"and "F"

2) Only available for styles "K"and "M"

Design

2-35

2

Hydraulics

D1VW_DW-Pos_gbPM6.5MM

Catalogue HY11-2500/UK

2

Solenoidoptions

SolenoidconnectionConnector

as perEN 175301-803,without plugPlease order

plug separately.See Chapter 2accessories

Designseries

Not requiredfor ordering

Solenoidvoltage

Accessories

Further spool types, voltages and combinations onrequest.

Code Voltage

Code Accessories

End positionmonitored side B

107)

118)

End positionmonitored side A

Start positionmonitored side B

806,8)

7) Only style H, K and M8) Only style B, E and F

5) For alternating current use plugwith rectifier, and order with so-lenoid connection code W.Please order rectifier plug sepa-rately.

Start positionmonitored side A666,7)

Code Solenoid option

Standard valvewithout options

omit

withoutmanual override

K 12V=

J 24V=

U5) 98V=

G5) 205V=

Directional Control ValvesSeries D1VW/D1DW with ind. pos. control

T6)

6) For hydraulic presses accord-ing to the safety regulations EN693, solenoid option "T" (withoutmanual override) and accesso-ries "66" or "80" (start positionmonitored) are required.

W

InductivePos. control,CE confirm

N

Ordering Code

2-36

D1VW_DW-Pos_gbPM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Dimensions / Test Certificate

The characteristic flow curves and shift limits correspond to the standard valve D1VW or D1DW.

Directional Control ValvesSeries D1VW/D1DW with ind. pos. control

AttentionThe switch may only be adjusted by the valve manu-facturer. The exchange of individual modules is notpermitted.

Test certificate:The trade association has awarded the test certificate98139 for the following directional valves with monitorswitch (accessories code 66/80):

D1VW (1 E/K; 20 B/H; 26 B/H; 30 B/H)D1DW (1 E/K; 20 B/H; 26 B/H; 30 B/H)

* Delivery includes plug M12 x 1 (see accessories, plug M12x1; order no.: 5004109).

DimensionsPosition control with plug M12x1*

B, E, F - style

H, K, M - style

BK375 4x M6x30 6.8 Nm ± 15% NBR: SK-D1VW-70/SK-D1DW70DIN 912 12.9 FPM: SK-D1VW-V70/SK-D1DW-V70

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-37

2

Hydraulics

D3W_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D3WCharacteristics

The D3W is a 3 chamber-, electrically controlled 4/3 or4/2 way directional control valve. It is activated directlyby solenoids with screwed in wet pin armature.

Characteristics

GeneralDesign Directional spool valveSize DIN NG10 / CETOP 05 / NFPA D05Interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight: Valve with 1 solenoid 4.8 kg

Valve with 2 solenoids 6.3 kg

HydraulicsFluids Hydraulic oil, in accordance with DIN 51524 / 51525Fuid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T DC: 210 bar AC: Standard 105 bar; Code H: 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 20 ml/min per flow path, depending on spool

Max. flow DC: 150 l/min AC: 115 l/min

Max. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle 100% ED; CAUTION: Coil temperature up to 150º C possibleProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)

Voltages (± 10%) Holding in Rush

DC voltage Code Power Current Power Current

12 V K 36 W 3 A - -24 V J 36 W 1.5 A - -98 V U 36 W 0.37 A -205 V G 36 W 0.18 A - -AC voltage110V 50Hz / 120 V 60 Hz Y 88 VA / 86 VA 0.80 A / 0.72 A 375 VA / 397 VA 3.41 A / 3.31 A230 V 50 Hz / 240 V 60 Hz T 88 VA / 86 VA 0.40 A / 0.36 A 385 VA / 408 VA 1.75 A / 1.70 A

Response times (at 80 l/min and 175 bar)(signal up to 95% spool stroke)

DC voltage AC voltage

Energized / deenergized 110 ms / 85 ms 21 ms / 35 ms

Max. switching frequency 10.000 switchings/hourSolenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.

2-38

D3W_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

WD

Directionalcontrolvalve

Wet pinarmaturesolenoidthreadedin tube3 chamber valve

Directional Control ValvesSeries D3WOrdering Code

SealsStyle

Spool type

3

SizeDIN NG 10CETOP 5

NFPA D05

1) Only available for DCvoltage.

Code

N NBR

V FPM

Seals

2-39

2

Hydraulics

D3W_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Further spool types, styles, and voltages on request.

Directional Control ValvesSeries D3W

Solenoid tubeoptions

Solenoidconnection

Designseries

Not requiredfor ordering

Solenoidvoltage

Code Voltage

110V 50Hz120V 60Hz

230V 50Hz240V 60Hz

Y

T

2) For AC voltage useplug with rectifier, andorder with solenoidconnection code W.Please order rectifierplug seperately.

Code Solenoid connection

3) Please order plug separately.See Chapter 2 accessories.

Conduit adapter withflying leads,

outlet on the front sideK

Connectoras per EN 175301-803,

without plugW3)

12V=

24V=

98V=

205V=

K

J

U2)

G2)

Accessories

Flying leads incavity, outlet on the

longitudinal sideC

Code Solenoid tube options

Standardsolenoid tube

(105 bar AC210 bar DC)

omit

High pressuresolenoid tube

tank press. 210bar(only for AC)

H

Manualoverrideoptions

Code Accessories

Signal light

Brad Harrison plug5 pin: 2 solenoids3 pin: 1 solenoid

Brad Harrison plug5 pin: 1solenoid

54)

Standard valveomit

65)

1A5)

Signal light withBrad Harrison plug5 pin: 2 solenoids3-pin: 1 solenoid

564)

Signal lightBrad Harrison plug5 pin: 1 solenoid

1C4)

without manualoverrideT

with manualoverrideomit

Code Manual override option

4) Only together with conduit adapter(code "K")

5) Only together with conduit adapter(code "K") or flying leads in cavity(code "C")

Ordering Code

2-40

D3W_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D3WFlow Curve

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values inthe diagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Position "b" Position "a" Position "0"

Spool P ->A B->T P->B A->T P->A P->B A->T B->T P->T A->B

1 4 3 4 3 - - - - - -

2 4 1 4 1 3 3 1 1 5 1

3 4 3 5 2 - - 4 - - -

4 4 2 4 2 - - 3 3 - 5

5 4 3 5 3 5 - - - - -

6 4 3 4 3 6 6 - - - 6

7 5 1 4 3 - 4 - 2 6 -

10 4 - 4 - - - - - - -

11 4 3 4 3 - - 8 8 - -

12 4 3 4 3 7 7 7 7 8 8

14 4 3 5 1 4 - 2 - 6 -

15 5 2 4 3 - - - 4 - -

16 5 3 4 3 - - 5 - - -

20 4 3 4 3 - - - - - -

26 4 - 4 - - - - - - -

30 4 2 4 2 - - - - - -

P->B A->T P->A B->T P->A P->B A->T B->T P->T A-> B

8 4 3 4 3 - - - - 6 -

9 4 4 4 4 - - - - 6 -

Position "b" Position "a"

P->A P->B A->B P->B A->T

21 5 4 6 3 3

P->A B->T P->A P->B A->B

22 3 3 4 5 6

Flow curve

2-41

2

Hydraulics

D3W_gb.PM6.5MM

Catalogue HY11-2500/UK

2

The diagram below specifies the shift limits for valves withDC solenoids. Valves of style “F” and “M” may only beloaded at 70% of the value. The specifications apply to aviscosity of 35 mm2/s and equal flow at A and B port.

Directional Control ValvesSeries D3WShift Limits

Shift limits, AC voltage

Shift limits, DC voltage

Measured at 90% Unom and warmed-up solenoids.

These values can be considerably lower than the repre-sented ones by unequal flow at A and B port. To avoidflow rates above the shift limits of the valve, a plug-inorifice can be inserted in the P port.

2-42

D3W_gb.PM6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D3WDimensions

Interface EN 175301-803: AC - Solenoid

B, E, F - style

C, D - style

H, K, M - style

DimensionsInterface EN 175301-8030: DC - Solenoid

B, E, F - style

C, D - style

H, K, M - style

BK385 4x M6x40 11 Nm ± 15% NBR: SK-D3W-30DIN 912 12.9 FPM: SK-D3W-V30

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-43

2

Hydraulics

D3DW_gb.PM6.5MM

Directional Control ValvesSeries D3DW - 5 Chamber Valve

Catalogue HY11-2500/UK

2

Characteristics

The D3DW is a 5 chamber-, electrically controlled 4/3 or4/2 way directional control valve. It is activated directlyby solenoids with screwed in wet pin armature.

Characteristics

GeneralDesign Directional spool valveSize DIN NG10 / CETOP 05 / NFPA D05Interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight: Valve with 1 solenoid 5.3 kg

Valve with 2 solenoids 6.8 kg

HydraulicsFluids Hydraulic oil, in accordance with DIN 51524 / 51525Fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 20 ml/min per flow path, depending on spoolMax. flow 130 l/minMax. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle 100% ED; CAUTION: Coil temperature up to 150º C possibleProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)

Voltages (± 10%)DC voltage Code Power Current

12 V K 36 W 3 A24 V J 36 W 1.5 A98 V U 36 W 0.37 A205 V G 36 W 0.18 A

Response times (signal up to 95% spool stroke) (at 65 l/min and 175 bar)Energized 115 msdeenergized 110 msMax. switching frequency 10.000 switchings/hourSolenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.

2-44

D3DW_gb.PM6.5MM

Hydraulics

Directional Control ValvesSeries D3DW - 5 Chamber Valve

Catalogue HY11-2500/UK

2

WD D

Directionalcontrolvalve

Wet pinarmaturesolenoid,threadedin tube

5 chambervalve

Ordering Code

SealsStyleSpool type

3

SizeDIN NG 10CETOP 5

NFPA D05

Code

N NBR

V FPM

Material

2-45

2

Hydraulics

D3DW_gb.PM6.5MM

Directional Control ValvesSeries D3DW - 5 Chamber Valve

Catalogue HY11-2500/UK

2

Further spool types, styles and voltages on request.

SolenoidconnectionConnector

as perEN 175301-803,without plugPlease order

plug separately.See Chapter 2accessories

Designseries

Not requiredfor ordering

Solenoidvoltage

Code Voltage

1) For alternating voltage use plugwith rectifier, and order withsolenoid connection code W.Please order rectifier plug sepa-rately.

12V=

24V=

98V=

205V=

K

J

U1)

G1)

without manualoverride optionT

with manualoverride optionomit

CodeManual override

option

Manual overrideoptions

W

Ordering Code

2-46

D3DW_gb.PM6.5MM

Hydraulics

Directional Control ValvesSeries D3DW - 5 Chamber Valve

Catalogue HY11-2500/UK

2

Flow Curve

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values inthe diagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Flow curve

Position "b" Position "a" Position "0"

Spool P ->A B->T P->B A->T P->A P->B A->T B->T P->T A->B

1 4 3 4 3 - - - - - -

2 4 1 4 1 3 3 1 1 5 1

3 4 3 5 2 - - 4 - - -

4 4 2 4 2 - - 3 3 - 5

5 4 3 5 3 5 - - - - -

6 4 3 4 3 6 6 - - - 6

7 5 1 4 3 - 4 - 2 6 -

10 4 - 4 - - - - - - -

11 4 3 4 3 - - 8 8 - -

12 4 3 4 3 7 7 7 7 8 8

14 4 3 5 1 4 - 2 - 6 -

15 5 2 4 3 - - - 4 - -

16 5 3 4 3 - - 5 - - -

20 4 3 4 3 - - - - - -

26 4 - 4 - - - - - - -

30 4 2 4 2 - - - - - -

P->B A->T P->A B->T P->A P->B A->T B->T P->T A-> B

8 4 3 4 3 - - - - 6 -

9 4 4 4 4 - - - - 6 -

Position "b" Position "a"

P->A P->B A->B P->B A->T

21 5 4 6 3 3

P->A B->T P->A P->B A->B

22 3 3 4 5 6

2-47

2

Hydraulics

D3DW_gb.PM6.5MM

Directional Control ValvesSeries D3DW - 5 Chamber Valve

Catalogue HY11-2500/UK

2

Shift Limits / Dimensions

The diagram below specifies the shift limits for valves withDC solenoids. Valves of style “F” and “M” may only beloaded at 70% of the value. The specifications apply to aviscosity of 35 mm2/s and equal flow at A and B port.

These values can be considerably lower than the repre-sented ones by unequal flow at A and B port. To avoidflow rates above the shift limits of the valve, a plug-inorifice can be inserted in the P port.

DimensionsInterface EN 175301-803: DC - Solenoid

B, E, F - style

C, D - style

H, K, M - style

BK385 4x M6x40 11 Nm ± 15% NBR: SK-D3DW-40DIN 912 12.9 FPM: SK-D3DW-V40

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

Measured at 90% Unom and warmed-up solenoids.

2-48Hydraulics

D3W_DWPos_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D3W/D3DW with ind. pos. controlCharacteristics

The 4/2 directional valves operated directly by solenoidswith inductive position control are used as monitoringvalves. The start or end position can be monitored. Theposition control is only available for single solenoid valves.

The fail save position of the directional valve during powerfailure is the spring offset position.

AttentionThe switch may only be adjusted by the valve manu-facturer. The exchange of individual modules is notpermitted.

Characteristics

GeneralDesign Directional spool valveNominal size DIN NG10 / CETOP 05 / NFPA D05Interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight: D3W 5.2 kg

D3DW 5.7 kg

HydraulicsOperating liquid Hydraulic oil, in accordance with DIN 51524 / 51525Pressure fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)Working pressure: P, A and B 350 bar

T 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 20 ml/min per flow path, depending on spoolMax. flow 150 l/min (D3W), 130 l/min (D3DW)Max. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Electrical characteristicsDuty cycle 100% ED; CAUTION: Coil temperature up to 150º C possibleProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)

Voltages (± 10%)DC voltage Code Power Current

12 V K 36 W 3 A24 V J 36 W 1.5 A98 V U 36 W 0.37A205 V G 36 W 0.18A

Response times (signal up to 95% spool stroke) D3W (at 80 l/min and 175 bar) D3DW (at 65 l/min and 175 bar)Energized 110 ms 115 ms

Deenergized 85 ms 110 msMax. switching frequency 10,000 switchings/hourSolenoid connection options Connector as per EN 175301-803, solenoid identification according to ISO 9461.

2-49

2

Hydraulics

D3W_DWPos_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D3W/D3DW with ind. pos. controlCharacteristics

Electrical characteristics - position control M12x1

Supply voltage 18 - 42 VRipple 10%Max. output current (ohmic load) 400 mA

IP65 as per DIN 40050Protection class (plugged and mounted)

Max. tolerance < 1200 A/mmagnetic ambient field strength at 50 Hz

Minimum distance > 100 mmto the next AC solenoid

Definitions:Start position monitored:The valve is deenergized. The inductive switch gives asignal at the moment (below 15% spool stroke) when thespool leaves the spring offset position.

Pin assignment

End position monitored:The inductive switch gives a signal before ending thestroke (above 85% spool stroke).

The switch can only be located opposite the solenoid for direct-controlled valves. This means, if the solenoid islocated on the A side of the valve, the switch can only take place on the B side.

1 Normally open2 + Supply

18...42V3 Normally closed4 0V5 Earth ground

M12 x 1-plug

2-50Hydraulics

D3W_DWPos_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Ordering Code

WD

Directionalcontrolvalve

Wet pinarmaturesolenoid,threadedin tube

SealsStyleSpool type

3

SizeDIN NG 10CETOP 5

NFPA D05

Directional Control ValvesSeries D3W/D3DW with ind. pos. control

Code Design

omit 3 chamber valve

D 5 chamber valve

3) Only position control code I2 or I54) Only position control code I1 or I4

Code

N NBR

V FPM

Seals

1) Only available for styles "K"and "M"

2) Only available for styles "E"and "F"

Design

2-51

2

Hydraulics

D3W_DWPos_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D3W/D3DW with ind. pos. control

SolenoidconnectionConnector

as perEN 175301-803,without plug

Please order plugseparately.See Chapter 2accessories

Designseries

Not requiredfor ordering

Solenoidvoltage

Positioncontrol

Code Voltage

Code Description

I 17)

I 28)

I 56,8)

5) For AC voltage use plug withrectifier, and order with solenoidconnection code W.Please order rectifier plug sepa-rately.

I 46,7)

12V=

24V=

98V=

205V=

K

J

U5)

G5)

T6)

omit

CodeManual override

option

Manual overrideoptions

InductivePos. control

with CE-code

N

Further spool types and voltages on request.

End positionmonitored, side B

End positionmonitored, side A

Start positionmonitored, side B

Start positionmonitored, side A

without manualoverride

with manualoverride

6) For hydraulic presses accordingto the safety regulations EN 693solenoid option "T" (withoutmanual override) and accesso-ries "I4" or "I5" (start positionmonitored) are required.

7) Only design H, K and M8) Only design B, E and F

W

Ordering Code

2-52Hydraulics

D3W_DWPos_gb.PM6.5MM

Catalogue HY11-2500/UK

2

Dimensions

Dimensions / Test Certificate

The characteristic flow lines and shift limits correspond to the standard valve D3W or D3DW.

Directional Control ValvesSeries D3W/D3DW with ind. pos. control

Attention

The switch may only be adjusted by the valve manu-facturer. The exchange of individual modules is notpermitted.

Position control with plug M12x1*) and protective cap

Test certificate:

The trade association has awarded the test certificate98140 for the following directional valve with monitorswitch (position control code I4 / I5):

D3DW (1 E/K; 20 B/H; 26 B/H; 30 B/H)

*) Delivery includes plug M12 x 1 (see accessories, plug M12x1; order no.: 5004109).

Interface EN 175301-803: DC - Solenoid

B, E, F - style

H, K, M - style

BK385 4x M6x40 11 Nm ± 15% NBR: SK-D3W-30/SK-D3DW-40DIN 912 12.9 FPM: SK-D3W-V30/SK-D3DW-V40

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.

2-53

2

Hydraulics

D1VP-3DP_GB.PM6.5MM

Directional Control ValvesSeries D1VP / D3DP

Catalogue HY11-2500/UK

2

The D1VP is a hydraulically controlled 4/3 or 4/2 waydirectional control valve. The valve can be operated ei-ther by the pilot ports X and Y via the subplate or by theconnection of an external pilot pipe direct on the valvebody.

The D3DP is a hydraulically controlled 4/3 or 4/2 waydirectional control valve. The valve is operated by thepilot ports X and Y via the subplate.

The minimum pilot pressure must be ensured for alloperating conditions of the directional valve.

Characteristics

GeneralDesign Directional spool valveSize DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP

RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature -25°C...+50°CWeight 1.3 kg

HydraulicsOperating liquid Hydraulic oil, in accordance with

DIN 51524 / 51525

Pressure fluid temperature -25°C to + 70°C

Viscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)

Working pressure: P, A, B and T 350 barX and Y minimum: 15 bar, maximum: 210 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path,depending on spool

Max. flow 80 l/min

Max. contamination level NAS 1638 class 7-9, to be achievedwith β10 > 75

Response times The response times are dependent on thepilot oil pressure and on the speed of theincrease / decrease of the pilot oil pres-sure. Recommended values for activatingare 13 ms and 20 ms for deactivating.

Characteristics

Directional spool valveDIN NG10 / CETOP 05 / NFPA D05DIN 24340 A10 / ISO 4401 / CETOPRP 35-H / NFPA D05unrestricted, preferably horizontal-25°C...+50°C3.7 kg

Hydraulic oil, in accordance withDIN 51524 / 51525

-25°C to + 70°C

2.8 to 400 mm2/s (2.8 to 400 cSt)

350 barminimum: 15 bar, maximum: 210 bar

up to 20 ml/min per flow path,depending on spool

130 l/min detent design 115 l/min

NAS 1638 class 7-9, to be achievedwith β

10 > 75

The response times are dependent on thepilot oil pressure and on the speed of theincrease / decrease of the pilot oil pres-sure. Recommended values for activatingare 20 ms and 30 ms for deactivating.

D1VP D3DP

2-54

D1VP-3DP_GB.PM6.5MM

Hydraulics

Directional Control ValvesSeries D1VP / D3DP

Catalogue HY11-2500/UK

2

SizeDIN NG 6CETOP 03NFPA D03

Style Pilot portWhitworthpipe thread

Hydraulicoperation

Directionalcontrolvalves

1 90VD

Spooltype

Seals Designseries

Not requiredfor new orders

Other spool types and voltages on request.

Ordering Code

Code

N NBR

V FPM

Seals

P

2-55

2

Hydraulics

D1VP-3DP_GB.PM6.5MM

Directional Control ValvesSeries D1VP / D3DP

Catalogue HY11-2500/UK

2

SizeDIN NG10CETOP 05NFPA D05

StyleHydraulicoperation

Directionalcontrolvalves

3 2DD

Spooltype

Seals Designseries

Not requiredfor new orders

Code

N NBR

V FPM

Seals

Ordering Code

P

Other spool types and voltages on request.

2-56

D1VP-3DP_GB.PM6.5MM

Hydraulics

Directional Control ValvesSeries D1VP / D3DP

Catalogue HY11-2500/UK

2

Flow curve / Dimensions

Dimensions

The characteristic flow lines are identical with the standard valve D1VW for D1VP and D3DW for D3DP.

Chracteristic flow lines

D1VP

D3DP

BK375 4x M5x30 6.8 Nm ± 15% NBR: SK-D1VP-70DIN 912 12.9 FPM: SK-D1VP-V70

Surface finish

BK385 4x M6x40 11 Nm ± 15% NBR: SK-D3DP-35DIN 912 12.9 FPM: SK-D3DP-V35

Surface finish

2-57Hydraulics

D4P-11P_GB.PM6.5MM

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

Mounting patterns

Series Size Mounting pattern

General

The D4P, D9P and D11P are hydraulically controlled 4/3or 4/2 way directional control valves. The valves areoperated by the pilot ports X and Y via the subplate.Pressure and flow of the pilot oil have a significantinfluence on the response time of the spool.

The minimum pilot pressure must be ensured for alloperating conditions of the directional valve.

DIN NG16 DIN 24340 design A16CETOP 7 ISO 4401NFPA D07 CETOP RP 121

NFPA D07

DIN NG25 DIN 24340 design A25CETOP 8 ISO 4401NFPA D08 CETOP RP 121

NFPA D08

DIN NG32 DIN 24340 design A32CETOP 10 ISO 4401NFPA D10 CETOP RP 121

NFPA D10

D4

D9

D11

2-58

D4P-11P_GB.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

Directionalcontrol valve

D

Ordering Code

StyleSpool typeHydraulicoperation

Size

P

1) all sizes (D4, D9, D11) available.2) only D4 and D9 available.3) only D9 available.

Code Bore Size

4 Ø20mm DIN NG169 Ø32mm DIN NG25

11 Ø50mm DIN NG32

2-59Hydraulics

D4P-11P_GB.PM6.5MM

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

Designseries

Pilot oilsupply and drainexternal/external

Seals Accessories

Code Material

N NBR

V FPM

2

Code Description Series

omit Standard valve without accessories

7 Pilot choke, meter-out

8 Stroke limit, side B

9 Stroke limit, side A

10 End position monitored, side A

11 End position monitored, side B

55 End position monitored,side A and B

660 Pilot choke, meter-in

66 Start position monitored, side A

80 Start position monitored, side B

88 Start position monitored,side A and B

89 Stroke limit on both sides

D1)

D1)

D2)

D2)

D1)4)

D1)4)

D1)4)

D1)

D1)4)

D1)4)

D1)4)

D2)

Ordering Code

1) All sizes (D4, D9, D11) available.2) Only D4 and D9 available.4) The plug M12x1 for monitor switch is included.

The monitor switch must be located on the side, to whichthe spool moves from the centre position.

All spools except spool 9:style B, E, F with 11 or 80style H, K, M with 10 or 66style C with 55 or 88

only spool 9:style E, F with 10 or 66style K, M with 11 or 80style C with 55 or 88

Following spool are available for monitoring:

D4P & D9P:Spool 1, 2, 3, 4, 7, 11, 14, 15, 9, 20, 30

D11P:Spool 1, 9

The monitor switch can be combined with some accesso-ries of the standard valve, these combinations have to beinquired at the factory.

2-60

D4P-11P_GB.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

Characteristics

Characteristics

General

Design Directional spool valve

Operation hydraulic

Mounting position unrestricted, preferably horizontal

Environmental temperature -25°C...+50°C

Nominal size DIN 24 340 16 25 32

CETOP 7 8 10

NFPA D07 D08 D10

Interface DIN 24340 A16-A25-A32 / ISO 4401 / CETOP RP 121-H / NFPA D07-D08-D10

Weight [kg] 9.0 17.0 66.0

Hydraulics

Operating liquid Hydraulic oil, in accordance with DIN 51524 / 51525

Pressure fluid temperature -25°C to + 70°C

Viscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)

Permissible degree of pollution NAS 1638 class 7-9, to be achieved with β10

> 75

Working pressure Ports P, A, B, T, X, Y 350 bar

Leakage at = 35 mm [s]per flow path ∆p = 175 bar up to 6o ml/min approx. 140 ml/min approx. 1,000 ml/min

∆p = 350 bar approx. 200 ml/min approx. 800 ml/min approx. 5,000 ml/minNominal flow [l/min] 300 700 2000

Pilot pressure 5 bar min.

Pilot oil on X Graphic symbol b (0)Y Graphic symbol a (0)

2-61Hydraulics

D4P-11P_GB.PM6.5MM

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

Electrical characteristics - position control M12x1

Supply voltage 18 - 42 VRipple 10%Max. output current (ohmic load) 400 mA

IP65 as per DIN 40050Protection class (plugged and mounted)

Max. tolerance < 1200 A/mmagnetic ambient field strength at 50 Hz

Minimum distance > 100 mmto the next AC solenoid

Definitions:Start position monitored:The valve is deenergized. The inductive switch gives asignal at the moment (below 15% spool stroke) when thespool leaves the spring offset position.

Pin assignment

End position monitored:The inductive switch gives a signal before ending thestroke (above 85% spool stroke).

1 Normally open2 + Supply

18...42V3 Normally closed4 0V5 Earth ground

M12 x 1-plug

Characteristics

2-62

D4P-11P_GB.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

Flow curves

SpoolCode P-A P-B P-T A-T B-T

D4 D4 D4 D4 D4

1 1 1 - 4 52 1 2 6 4 63 1 2 - 5 64 1 1 - 5 55 2 2 - 3 56 1 2 - 3 67 1 1 6 4 59 2 9 8 7 1011 1 1 - 4 514 1 1 6 4 515 1 2 - 4 616 2 2 - 3 520 3 5 - 3 521 2 8 - 2 -26 3 5 - - -30 2 3 - 6 754 2 3 - 6 756 1 1 - 4 -58 1 1 - 3 459 1 1 - 4 361 1 2 - 5 6

D9 and D11

SpoolCode P-A P-B P-T A-T B-T

D9 D11 D9 D11 D9 D11 D9 D11 D9 D11

1 3 5 2 5 - - 3 4 5 12 2 5 1 5 1 5 3 4 5 13 4 - 2 - - - 3 - 6 -4 4 - 3 - - - 3 - 5 -5 1 - 2 - - - 4 - 5 -6 2 - 2 - - - 4 - 6 -7 3 - 1 - 7 - 3 - 5 -9 4 3 8 3 9 2 4 3 10 111 3 - 2 - - - 3 - 5 -14 1 - 2 - 8 - 3 - 5 -15 3 - 3 - - - 4 - 5 -16 3 - 3 - - - 4 - 5 -20 6 5 5 5 - - 6 3 8 -21 5 - 10 - - - 3 - - -30 3 5 2 5 - - 3 4 5 154 - 5 - 5 - - - 4 - 156 - 5 - 5 - - - 4 - -58 - 5 - 5 - - - 4 - 159 - 5 - 5 - - - 4 - 1

Flow curve D4

Flow curve D9

Flow curve D11

D4

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values inthe diagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Curve number

Curve number

2-63Hydraulics

D4P-11P_GB.PM6.5MM

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

D9P

Dimensions

D4P

BK320 4 xM10x60 54 Nm ± 15% NBR: SK-D41VW-702 xM6x55 11 Nm ± 15% FPM: SK-D41VW-V70

DIN 912 12.9

Surface finish

BK360 6x M12x75 94 Nm ± 15% NBR: SK-D91VW-70DIN 912 12.9 FPM: SK-D91VW-V70

Surface finish

2-64

D4P-11P_GB.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D4P - D11P

Catalogue HY11-2500/UK

2

Dimensions

D11P

BK386 6x M20x90 460 Nm ± 15% NBR: SK-D111VW-70DIN 912 12.9 FPM: SK-D111VW-V70

Surface finish

The space necessary to remove the plug for M12x1 is at least 12 mm.

2-65

2

Hydraulics

D1VC-VD_gb.PM6.5MM

Directional Control ValvesSeries D1VC / D1VD

Catalogue HY11-2500/UK

2

The D1VC/D1VD is a 3 chamber 4/2 way directional con-trol valve. It is operated mechanically with a cam.

GeneralDesign Directional spool Valve

Size DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature - 25°C...+ 50°C

Weight 1.6 kg

HydraulicsOperating liquid Hydraulic oil in accordance with DIN 51524 / 51525Pressure fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)

Working pressure: P, A and B 350 barT 10 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path, depending on spool

Max. flow 80 l/min

Operating force 107 N

Max. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75

Characteristics

Characteristics

2-66

D1VC-VD_gb.PM6.5MM

Directional Control ValvesSeries D1VC / D1VD

Hydraulics

Catalogue HY11-2500/UK

2

D V

Directionalcontrolvalve

3chamber

valve

Seals

Code

N NBR

V FPM

Seals

Spool type

1

SizeDIN NG 6CETOP 3

NFPA D03

Ordering Code

Style Designseries

Not requiredfor new orders

Code

omit Standard

P05 short stroke

Stroke optionsCode

Cam 90° to theC connecting

surface

Cam parallel toD the connecting

surface

Description

Strokeoptions

Operation

2-67

2

Hydraulics

D1VC-VD_gb.PM6.5MM

Directional Control ValvesSeries D1VC / D1VD

Catalogue HY11-2500/UK

2

Flow Curve

Position "b" Position "a"

Spool P ->A B->T P->B A->T

1 3 1 3 1

2 4 2 4 2

Flow Curve

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values inthe diagram, the curve number for the selected spool anddesired operating position must first be determined fromthe table right.

2-68

D1VC-VD_gb.PM6.5MM

Directional Control ValvesSeries D1VC / D1VD

Hydraulics

Catalogue HY11-2500/UK

2

Dimensions

Style "H"

Style "B"

BK375 4x M5x30 6,8 Nm ± 15% NBR: SK-D1VW-70DIN 912 12.9 FPM: SK-D1VW-V70

Surface finish

2-69

2

Hydraulics

D1-D3DL_gb.6.5MM

Catalogue HY11-2500/UK

2

Characteristics

GeneralDesign Directional spool valveSize DIN NG6 / CETOP 03 / NFPA D03Interface DIN 24340 A6 / ISO 4401 / CETOP

RP 121-H / NFPA D03Mounting position unrestricted, preferably horizontalEnvironmental temperature - 25°C...+ 50°C

Weight 1.4 kg

HydraulicsOperating liquid Hydraulic oil, in accordance with

DIN 51524 / 51525Pressure fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2,8 bis 400 cSt)

Working pressure: P, A and B 350 barT 10 bar

Leakage: ∆p = 50 bar; ν = 35 mm2/s up to 10 ml/min per flow path,depending on spool

Max. flow 80 l/minMax. contamination level NAS 1638 class 7-9, to be achieved

with β10 > 75

Directional Control ValvesSeries D1DL / D3DLCharacteristics

The D1DL and the D3DL are 5 chamber 4/3 or 4/2 waydirectional control valves. They are operated by a handlever.

The hand lever can be located either on the A or B side.Spring offset and detent designs are available. The handlever valve is sea water resistant.

Directional spool valveDIN NG10 / CETOP 05 / NFPA D05DIN 24340 A10 / ISO 4401 / CETOPRP 35-H / NFPA D05unrestricted, preferably horizontal- 25°C...+ 50°C

5.0 kg

Hydraulic oil, in accordance withDIN 51524 / 51525-25°C to + 70°C2.8 to 400 mm2/s (2.8 bis 400 cSt)

350 bar10 barbis 20 ml/min per flow path,depending on spool

130 l/minNAS 1638 class 7-9, to be achievedwith β10 > 75

D1DL D3DL

2-70

D1-D3DL_gb.6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValveSeries D1DL / D3DLOrdering Code

D D

Directionalcontrolvalve

5chamber

valve

StyleSpool typeSize

Code

Hand leverside B

Hand leverside A

L

LB

Description

DIN NG 6CETOP 3NFPA D03DIN NG 10CETOP 5NFPA D05

1

3

1) Only for D3DL available

2) For D1D only operation LB availableFor D3D operation L and LB available

3) For D1D only operation L availableFor D3D operation L and LB available

Operation

Code

N NBRV FPM

SealsCode Size

Seals Designseries

2-71

2

Hydraulics

D1-D3DL_gb.6.5MM

Catalogue HY11-2500/UK

2

Directional Control ValveSeries D1DLFlow Curves / Dimensions

Flow Curves

The characteristic flow curves are identical with the standard valve D1VW.

D1DL

D1DLB

BK375 4x M5x30 6.8 Nm ± 15% NBR: SK-D1DL-75DIN 912 12.9 FPM: SK-D1DL-V75

Surface finish

2-72

D1-D3DL_gb.6.5MM

Hydraulics

Catalogue HY11-2500/UK

2

Directional Control ValvesSeries D3DLFlow Curves / Dimensions

Flow Curves

The characteristic flow curves are identical with the standard valve D3DW.

D3DL

D3DLB

BK385 4x M6x40 11 Nm ± 15% NBR: SK-D3DL-35DIN 912 12.9 FPM: SK-D3DL-V35

Surface finish

2-73Hydraulics

D4l-9l_gb.PM6.5MM

Manually Operated Directional ValvesSeries D4L - D9L

Catalogue HY11-2500/UK

2

Mounting patterns

Series Size Mounting pattern

General

DIN NG16 DIN 24340 design A16CETOP 7 ISO 4401NFPA D07 CETOP RP 121

NFPA D07

DIN NG25 DIN 24340 design A25CETOP 8 ISO 4401NFPA D08 CETOP RP 121

NFPA D08

D4

D9

The D4L and D9L are 5 chamber 4/3 or 4/2 way direc-tional control valves. They are operated by a hand lever.

The hand lever can be located either on the A or B side.Spring offset and detent designs are available. The handlever valves are sea water resistant.

2-74

D4l-9l_gb.PM6.5MM

Hydraulics

Manually Operated Directional ValvesSeries D4L - D9L

Catalogue HY11-2500/UK

2

Directionalcontrolvalve

D

Ordering Code

Style

Code Bore Size

4 Ø20mm DIN NG169 Ø32mm DIN NG25

Series Operation

leverside B

leverside A

L

LB

OperationCode

Spool type

1) only D4L available

2-75Hydraulics

D4l-9l_gb.PM6.5MM

Manually Operated Directional ValvesSeries D4L - D9L

Catalogue HY11-2500/UK

2

Designseries

not requiredfor new orders

Pilot oildrain

Code Seals

N NBR

V FPM

Code Inlet Outlet

52) - internal

23) - external

Seals

2) Pressure T-port < 10 bar3) Pressure T-port > 10 bar

2-76

D4l-9l_gb.PM6.5MM

Hydraulics

Manually Operated Directional ValvesSeries D4L - D9L

Catalogue HY11-2500/UK

2

Characteristics

Characteristics

GeneralDesign Directional spool valve

Operation manualMounting position unrestricted, preferably horizontal

Environmental temperature - 25°C...+ 50°CSize DIN 24 340 16 25

CETOP 7 8NFPA D07 D08

Interface DIN 24340 A16-A25 / ISO 4401 / CETOP RP 121-H / NFPA D07-D08

Weight [kg] 9.0 17.0

HydraulicsOperating liquid Hydraulic oil, in accordance with DIN 51524 / 51525Pressure fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 to 400 cSt)

Max. contamination level NAS 1638 class 7-9, to be achieved with β10 > 75Working pressure: P, A, B, 350 bar

T : external drain 350 barT : internal drain < 10X, Y: < 10

Leakage at ν = 35 mm [s]per flow path ∆p = 175 bar ml/min up to 6o approx. 140

∆p = 350 bar ml/min approx. 200 approx. 800Nominal flow [l/min] 300 700

2-77Hydraulics

D4l-9l_gb.PM6.5MM

Manually Operated Directional ValvesSeries D4L - D9L

Catalogue HY11-2500/UK

2

Flow curves

SpoolCode P-A P-B P-T A-T B-T

D4 D4 D4 D4 D4

1 1 1 - 4 52 1 2 6 4 63 1 2 - 5 64 1 1 - 5 56 1 2 - 3 67 1 1 6 4 59 2 9 8 7 10

14 1 1 6 5 415 2 1 - 6 520 3 5 - 3 530 2 3 - 6 7

D9

SpoolCode P-A P-B P-T A-T B-T

D9 D9 D9 D9 D9

1 3 2 - 3 52 2 1 1 3 53 4 2 - 3 64 4 3 - 3 57 3 1 7 3 59 4 8 9 4 10

14 1 3 7 5 315 2 4 - 5 320 6 5 - 6 830 3 2 - 3 5

Flow curve D4

Flow curve D9

D4

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values inthe diagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

Curve number

Curve number

2-78

D4l-9l_gb.PM6.5MM

Hydraulics

Manually Operated Directional ValvesSeries D4L - D9L

Catalogue HY11-2500/UK

2

D9LB

Dimensions

D4LB

BK360 6x M12x75 94 Nm ± 15% NBR: SK-D9L-60DIN 912 12.9 FPM: SK-D9L-V60

Surface finish

4x M10x60 54 Nm ± 15% NBR: SK-D4L-60BK320 2x M6x55 11 Nm ± 15% FPM: SK-D4L-V60

DIN 912 12.9

Surface finish

2-79Hydraulics

D3-D11_gb.PM6.5MM

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Mounting patterns

Series Size Mounting pattern

DIN NG 10 DIN 24340 design A10D3 CETOP 5 ISO 4401

NFPA D05H CETOP RP121NFPA D05H

DIN NG 16 DIN 24340 design A16D4 CETOP 7 ISO 4401

NFPA D07 CETOP RP121NFPA D07

DIN NG 25 DIN 24340 design A25D8/9 CETOP 8 ISO 4401

NFPA D08 CETOP RP121NFPA D08

DIN NG 32 DIN 24340 design A32D11 CETOP 10 ISO 4401

NFPA D10 CETOP RP121NFPA D10

General

The D31, D41, D81, D91 and D111 are electrical control-led 4/3 or 4/2 way directional control valves. The valvesare pilot operated by an NG6 valve.

Pressure and flow of the pilot oil have a significantinfluence on the response time of the spool in the mainstage.

In order to guarantee a save switching of the spool pleasechoose the appropriate pilot oil supply and drain option.(Spools with a connection P to T need an externalpressure supply or an integral check valve. For spoolswith negative cross-over position are the same optionsrecommended.)

The minimum pilot pressure must be ensured for alloperating condition of the directional valve.

2-80

D3-D11_gb.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Directionalcontrol valve

D

Ordering Code

Style

Code Bore Size

3 Ø11mm DIN NG 104 Ø20mm DIN NG168 Ø26mm DIN NG259 Ø32mm DIN NG2511 Ø50mm DIN NG32

Code Style

D D3V D4, D8/9, D111

PilotNG6

Series

1 W

Style Electricaloperated

Spooltype

1) all sizes (D31, D41, D81, D91,D111) available

2) only D31, D41, D81, D91 available3) only D41, D81, D91, D111 available4) only D31, D81, D91 available

Catalogue HY11-2500/UK

2-81Hydraulics

D3-D11_gb.PM6.5MM

Pilot Operated Directional Control ValvesSeries D3-D11

2

Code Inlet Outlet

1 internal external

2 external external

35) integralcheck valve external

4 internal internal

5 external internal

65) integralcheck valve internal

Designseries

Code Description

omit Standard solenoidwithout options

T without manualoverride

W splash proof

Code Solenoid connection

C Conduit box flying leads

Connector asW7) per EN 175301-803,

without plug

Pilot oilsupply and

drain options

Seals Solenoidvoltage

Solenoidconnection

Solenoidoptions

Accessories

Code Material

N NBR

V FPM

1) all sizes (D31, D41, D81, D91, D111) available2) only D31, D41, D81, D91 available

5) only D41, D81 available

7) Please order plug separately.See page 2-90 accessories.

Code Voltage

6) For alternating current use plug withrectifier, and order with solenoidconnection code W.Please order rectifier plug sepa-rately.

12V=

24V=

98V=

205V=110V 50Hz120V 60Hz

230V 50Hz240V 60Hz

K

J

U6)

G6)

Y

T

Code Description Series

omitStandard valve without

D1)accessories

2 Pilot with press. reducing valve D1)

5Signal light and terminal strip

D1)in a conduit box

6Brad Harrison connector

D1)male plug in a conduit box

7 Pilot choke, meter-out D1)

8 Stroke adjustment, side B D2)

9 Stroke adjustment, side A D2)

56 Option 5 and 6 combined D1)

660 Pilot choke, meter-in D1)

89 Stroke adjustment, side A and B D2)

Explosion proof solenoids EEx me II on request.

Ordering Code

2-82

D3-D11_gb.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

with ind. pos. control

Directionalcontrol valve

D

Style

Code Bore Size

3 Ø11mm DIN NG 104 Ø20mm DIN NG168 Ø26mm DIN NG259 Ø32mm DIN NG25

11 Ø50mm DIN NG32

Code Series

D D3V D4, D8/9, D111

PilotNG6

Series

1

1) all sizes (D3, D4, D8, D9, D11) avail-able.

2) only D3, D4, D8, D9 available.3) only D4, D8, D9, D11 available.4) only D4, D8, D9 available.

W

Style Electricaloperated

Spooltype

Ordering Code

2-83Hydraulics

D3-D11_gb.PM6.5MM

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

with ind. pos. control

Code Inlet Outlet

1 internal external

2 external external

integral35) check external

valve

4 internal internal

5 external internal

integral65) check internal

valve

Designseries

Code Solenoid options

omit Standard solenoidwithout options

T8) without manualoverride

W splash proof

Code Solenoid connection

Conduit boxC flying leads

Connector as perW7) EN 175301-803,

without plug

Pilot oilsupply and

drainoptions

Seals Solenoidvoltage

Solenoidconnection

Solenoidoptions

Accessories

Code Seals

N NBR

V FPM

The monitor switch has to be located on the side towhich the spool moves from the spring offsetposition.For all spools except spool 9:Style B, E, F uses 11 or 80Style H, K, M uses 10 or 66Style C uses 55 or 88

For spool 9:Style E, F uses 10 or 66Style K, M uses 11 or 80Style C uses 55 or 88

The montor switch can use some accessories fromthe standard valve, but combinations must beinquired at the manufacturer.1) All sizes (D31, D41, D81, D91, D111) available.

5) only D41, D81 available

Code Voltage

6) For alternating current useplug with rectifier, and orderwith solenoid connectioncode W.Please order rectifier plugseparately.

K 12V=

J 24V=

U6) 98V=

G6) 205V=

Code Description Series

10End position monitored,

D1)side A

11End position monitored,

D1)side B

55End position monitored,

D1)side A and B

66Start position monitored,

D1)8)side A

80Start position monitored,

D1)8)side B

88Start position monitored,

D1)8)side A and B

The plug M12 x 1 for the position control is included.

8) For hydraulic presses accord-ing to the safety regulations EN693, solenoid option "T" (with-out manual override) and ac-cessories "66", "80" or "88"(start position monitored) arerequired.

7) Please order plug separately.See chapter 2 accessories.

Ordering Code

2-84

D3-D11_gb.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Characteristics

Characteristics

GeneralDesign Directional spool valve

Operation SolenoidMounting position unrestricted, preferably horizontalEnvironmental temperature - 25°C...+ 50°CSize DIN 24 340 10 16 25 32

CETOP 5 7 8 10NFPA D05H D07 D08 D10

Mounting pattern DIN 24340 A10-16-25-32 / ISO 4401 / CETOP RP 121-H / NFPA D05-D07-D08-D10

Weight 1 / 2 solenoids [kg] 6.0 / 6.6 9.7 / 10.3 17.9 / 18.5 67.4 / 68.0

HydraulicsFluids Hydraulic oil, in accordance with DIN 51524 / 51525Fluid temperature -25°C to + 70°CViscosity range ν 2.8 to 400 mm2/s (2.8 bis 400 cSt)

Max. contamination level NAS 1638 class 7-9, to be achieved mit β10 > 75

Working pressure Pilot drain external Ports P, A, B, T, X 350 bar Port Y max.100 bar

option internal P, A, B, X 350 bar Ports T, Y max. 100 bar

Leakage at ν = 35 mm [s]Pilot [ml/min] 30 at 350 bar

Main stage/adge ∆p = 175 bar [ml/min] up to 20 up to 60 approx. 140 approx. 1000∆p = 350 bar [ml/min] approx. 100 approx. 200 approx. 800 approx. 5000

Max. flow [l/min] 100 300 700 2000

Opening pressure _ 4 4 _

Integral check valve in P [bar] see P/Q diagrams

Pilot pressure [bar] 5 min.

Response times [ms] energized / deenergized

DC - Solenoids pilot pressure 50 bar 59 / 35 95 / 70 150 / 170 470 / 390100 bar 55 / 35 75 / 65 110 / 170 320 / 390250 bar 55 / 35 60 / 60 90 / 170 210 / 390350 bar 54 / 35 60 / 60 86 / 170 200 / 390

AC - Solenoids 50 bar 36 / 42 55 / 55 130 / 170 470 / 390100 bar 35 / 42 45 / 55 90 / 170 320 / 390250 bar 35 / 42 33 / 55 70 / 210 210 / 390350 bar 35 / 42 30 / 55 65 / 200 200 / 390

2-85Hydraulics

D3-D11_gb.PM6.5MM

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Electrical characteristicsDuty cycle 100% EDProtection class IP 65 in accordance with DIN 40050 (plugged and mounted)Connection type Connector as per EN 175301-803, solenoid identification according to ISO 9461.

Conduit box with flying leads, optional with Brad Harrison plug.

Voltages (± 10%) Holding in RushDC voltage Code Power Current Power Current

12 V K 30 W 2.5 A - -24 V J 30 W 1.25 A - -98 V U 30 W 0.31 A - -198 V G 30 W 0.15 A - -

AC voltage110V 50 Hz / 120V 60 Hz Y 64 VA / 59 VA 0.58 A / 0.49 A 231 VA / 240 VA 2.1 A / 2.0 A230V 50 Hz / 240V 60 Hz T 68 VA / 62 VA 0.31 A / 0.26 A 231 VA / 240 VA 1.05 A / 1.0 A

Electrical characteristics - position control M12x1

Supply voltage 18 - 42 VRipple 10%Max. output current (ohmic load) 400 mA

IP65 as per DIN 40050Protection class (plugged and mounted)

Max. tolerance < 1200 A/mmagnetic ambient field strength at 50 Hz

Minimum distance > 100 mmto the next AC solenoid

Definitions:Start position monitored:The valve is deenergized. The inductive switch gives asignal at the moment (below 15% spool stroke) when thespool leaves the spring offset position.

Pin assignment

End position monitored:The inductive switch gives a signal before ending thestroke (above 85% spool stroke).

1 Normally open2 + Supply

18...42V3 Normally closed4 0V5 Earth ground

M12 x 1-plug

Characteristics

2-86

D3-D11_gb.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Flow curves

Curve numberSpoolCode P-A P-B P-T A-T B-T

D3 D4 D3 D4 D3 D4 D3 D4 D3 D4

1 3 1 3 1 - - 1 4 1 52 3 1 3 2 4 6 1 4 1 63 3 1 4 2 - - 1 5 1 64 3 1 3 1 - - 1 5 1 55 3 2 4 2 - - 1 3 1 56 3 1 3 2 - - 1 3 1 67 4 1 3 1 - 6 1 4 1 59 3 2 3 9 8 8 1 7 1 1011 3 1 3 1 - - 1 4 1 514 3 1 4 1 - 6 1 4 1 515 4 1 3 2 - - 1 4 1 616 4 2 3 2 - - 1 3 1 520 3 3 4 5 - - 1 3 1 521 4 2 3 8 - - 1 2 - -26 3 3 3 5 - - - - - -30 3 2 1 3 - - 1 6 1 754 - 2 - 3 - - - 6 - 758 - 1 - 1 - - - 3 - 459 - 1 - 1 - - - 4 - 3

D81/D91 and D111Curve number

SpoolCode P-A P-B P-T A-T B-T

D8/9 D11 D8/9 D11 D8/9 D11 D8/9 D11 D8/9 D11

1 3 5 2 5 - - 3 4 5 12 2 5 1 5 1 5 3 4 5 13 4 - 2 - - - 3 - 6 -4 4 - 3 - - - 3 - 5 -5 1 - 2 - - - 4 - 5 -6 2 - 2 - - - 4 - 6 -7 3 - 1 - 7 - 3 - 5 -9 4 3 8 3 9 2 4 3 10 111 3 - 2 - - - 3 - 5 -14 1 - 2 - 8 - 3 - 5 -15 3 - 3 - - - 4 - 5 -16 3 - 3 - - - 4 - 5 -20 6 5 5 5 - - 6 3 8 -21 5 - 10 - - - 3 - - -26 6 - 5 - - - - - - -30 3 5 2 5 - - 3 4 5 154 4 5 3 5 - - 3 4 5 156 4 - 3 - - - 3 - - -58 4 5 2 5 - - 3 4 6 159 3 5 3 5 - - 4 4 5 1

Flow curve D31

Flow curve D41

Flow curve D81/D91

Flow curve D111

D31 and D41

The flow curve diagram shows the flow versus pressuredrop curves for all spools shown. To read the values inthe diagram, the curve number for the selected spool and

desired operating position must first be determined fromthe table below.

2-87Hydraulics

D3-D11_gb.PM6.5MM

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Integral Check Valve / Pilot Oil Options

Integral check valve in the P port

Mounting an integral check valve in the P port is neces-sary to build up the minimal pilot pressure for valves withP to T connection and internal pilot oil supply. The pres-sure difference at the integral check valve (see perform-

ance curves) is to be added to all flow curves of the P-port of the main valve. Directional valves with an integralcheck valve are available for the series D41 and D81.

Flow curve D81Flow curve D41

All orifice sizes for standard valves.

2-88

D3-D11_gb.PM6.5MM

Hydraulics

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Dimensions

D31DW

D41VW

BK385 4x M6x40 11 Nm ± 15% NBR: SK-D31DW-75DIN 912 12.9 FPM: SK-D31DW-V75

Surface finish

BK320 4x M10x60 54 Nm ± 15% NBR: SK-D41VW-702 x M6x55 11 Nm ± 15% FPM: SK-D41VW-V70

DIN 912 12.9

Surface finish

2-89Hydraulics

D3-D11_gb.PM6.5MM

Pilot Operated Directional Control ValvesSeries D3-D11

Catalogue HY11-2500/UK

2

Dimensions

D81/D91VW

D111VW

BK360 6x M12x75 94 Nm ± 15% NBR: SK-D81VW-70/SK-D91VW-70DIN 912 12.9 FPM: SK-D81VW-V70/SK-D91VW-V70

Surface finish

BK386 6x M20x90 460 Nm ± 15% NBR: SK-D111VW-70DIN 912 12.9 FPM: SK-D111VW-V70

Surface finish

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for thescrew M3 of the plug has to be 0.5 to 0.6 Nm.The space necessary to remove the plug for M12x1 is at least 12 mm.

2-90

Zubehör_gb.PM6.5MM

Hydraulics

Directional Control ValvesAccessories

Catalogue HY11-2500/UK

2

DescriptionOrder No.Figure

circuitCable

connection

5001710 5001711

5001716 5001717

Plug EN 175301-803 *, style AF

Protection class IP 65 for voltages up to 250V

5001571 5001572Plug with LED 24V DC

Plug with lamp insert 120V AC

Plug with lamp insert 230V AC

Plug with LED 24 V DC and suppressing circuit

Plug with cable strain relief and transparent cover

Inserts for plug 5001723 and 5001724

Plug with rectifier:Bridge-type rectifier with silicon diodes. Varistors are used toprotect the diodes against power surges from the power supplyup to 250V AC.

Fig. 1and Fig. 6

5001737 5001738

Fig. 1

and Fig.55001708 5001709

5001573 50015745001575 5001576

PG 11

Fig. 1

Fig. 1

and Fig.4

Fig. 1

and Fig.3

Fig. 2

PG 9

PG 11

PG 11

5001723 5001724

black (B) grey (A)

Bridge-type rectifier up to 250V AC 7 5001727Lamp 250V AC 4 5001730

Bridge-type rectifier with lamp 250V AC 8 5001734

Order No.Circuit

Plugs EN 175301-803

* (New) EN 175301-803 corresponds to (old) DIN 43650.

2-91

2

Hydraulics

Zubehör_gb.PM6.5MM

Directional Control ValvesAccessories

Catalogue HY11-2500/UK

2

Conduit boxes

Plug M12x1, Conduit Boxes

Plug M12x1

The angled plug for M12x1 is a 5 pin design. The connections in the plug can be screwed in.The plug can be turned 4 x 90° .

Order No.: 5004109

2-92

Zubehör_gb.PM6.5MM

Hydraulics

Directional Control ValvesAccessories

Catalogue HY11-2500/UK

2

Actuator Kits

Solenoid kit(shown: EN plug)

Coil kit(shown: flying leads)

1) D1DW only with DC voltages

Coil kits: AK-D1VW-C-... (Example: AK-D1VW-C-JW-75)

EN plug without manualVoltage Voltage EN plug override (Code "T") Flying leads

Volt/Hertz Code D1VW / D1DW1) D1VW / D1DW1) D1VW

12V= K KW-75 KWT-75 -24V= J JW-75 JWT-75 JC-7598V= U UW-75 UWT-75 -

205V= G GW-75 GWT-75 -

110V/50Hz,120V/60Hz Y YW-70 - YC-70230V/50Hz,240V/60Hz

T TW-70 - TC-70

For D1VW 8-WattSolenoid kits: AK-D1VW-S-... Coil kits: AK-D1VW-C-...

M12x1 "DESINA" M12x1 "DESINA"Voltage Voltage EN plug (Code "DLJ5") EN plug (Code "DLJ5")

Volt/Hertz Code D1VW D1VW D1VW D1VW

24V= J JWL-75 JDLJ5-75 JWL-75 JDLJ5-75

Solenoid kits: AK-D1VW-S-... (Example: AK-D1VW-S-JW-75)

EN plug without manual EN plug with 210bar tankVoltage Voltage EN plug override (Code "T") pressure (Code "H") Flying leads

Volt/Hertz Code D1VW / D1DW1) D1VW / D1DW1) D1VW / D1DW1) D1VW

12V= K KW-75 KWT-75 KW-75 -24V= J JW-75 JWT-75 JW-75 JC-7598V= U UW-75 UWT-75 UW-75 -

205V= G GW-75 GWT-75 GW-75 -

110V/50Hz120V/60Hz Y YW-70 - YWH-70 YC-70

230V/50Hz240V/60Hz

T TW-70 - TWH-70 TC-70

For D1VW /D1DW (without 8-Watt and Soft Shift)

Solenoid kits: AK-D3W-S-... (Example: AK-D3W-S-JW-30) Coil kits: AK-D3W-C-...

EN plug without manual EN plug with 210bar tank EN plug without manualVoltage Voltage EN plug override (Code "T") pressure (Code "H") EN plug override (Code "T")Volt/Hertz Code D3W / D3DW1) D3W / D3DW1) D3W / D3DW1) D3W / D3DW1) D3W / D3DW1)

12V= K KW-30 KWT-30 KW-30 KW-30 KWT-3024V= J JW-30 JWT-30 JW-30 JW-30 JWT-3098V= U UW-30 UWT-30 UW-30 UW-30 UWT-30205V= G GW-30 GWT-30 GW-30 GW-30 GWT-30

110V/50Hz,120V/60Hz Y YW-30 - YWH-30 YW-30 -230V/50Hz, 240V/60Hz

T TW-30 - TWH-30 TW-30 -

For D3W / D3DW

1) D3DW only with DC voltagesOther solenoid and coil kits on request.A solenoid kit contains: tube, coil, retainer and seals for the solenoid.A coil kit contains: coil, retainer and seals for the coil.

For D1VW Soft Shift: on request

AC ACDC DC

2-93

2

Hydraulics

Zubehör_gb.PM6.5MM

Directional Control ValvesAccessories

Catalogue HY11-2500/UK

2

Valve Mate-Series rial D1V D1D D3 D3D D31D D4 D8 D9 D11

D**WNBR SK- SK- SK- SK- SK- SK- SK- SK- SK-

SolenoidD1VW-70 D1DW-75 D3W-30 D3DW-40 D31DW-75 D41VW-70 D81VW-70 D91VW-70 D111VW-70

FPM SK- SK- SK- SK- SK- SK- SK- SK- SK-D1VW-V70 D1DW-V75 D3W-V30 D3DW-V40 D31DW-V75 D41VW-V70 D81VW-V70 D91VW-V70 D111VW-V70

D**P NBR SK- SK- SK- SK- SK-hydr. D1VP-70 - - D3DP-35 - D41VW-70 - D91VW-70 D111VW-70

FPM SK- SK- SK- SK- SK-D1VP-V70 - - D3DP-V35 - D41VW-V70 - D91VW-V70 D111VW-V70

D*L/LB NBR SK- SK- SK- SK-hand - D1DL-75 - D3DL-35 - D4L-60 - D9L-60 -lever

FPM SK- SK- SK- SK-- D1DL-V75 - D3DL-V35 - D4L-V60 - D9L-V60 -

O-Rings and Seal Kits

O-Rings to seal between valve and mounting surface

Valve Valve Ports Dimensions Quantity*Size Series inner Ø x section Ø

DIN NG 6D1V P, A, B, T 9.25 x 1.78 4D1D X, Y 4.47 x 1.78 2

DIN NG10 D3P, A, B, T 12.42 x 1.78 5

X, Y 10.82 x 1.78 2

DIN NG 16 D4P, A, B, T 21,89 x 2,62 4

X, Y 10.82 x 1.78 2

DIN NG 25 D8P, A, B, T 29.82 x 2.62 4

X, Y 20.29 x 2.62 2

DIN NG 25 D9P, A, B, T 34.59 x 2.62 4

X, Y 20.29 x 2.62 2

DIN NG 32 D11P, A, B, T 53.57 x 3.53 4

X, Y 14.00 x 1.78 2

*Number per set

Seal kits (connecting surface and inner seals)

Order code for valve size

2-94

Zubehör_gb.PM6.5MM

Hydraulics

Directional Control ValvesAccessories

Catalogue HY11-2500/UK

2

Slip-in orifice

Slip-in orifice for P, A, B, T-Port of directional control valves NG6 and NG10

Dimensions

Package size: each kit contains 10 orifice of the same size

DK

Orifice kit Nominalsize

Code

D1VW75 NG6

D3W30 NG10

Size Code

00 without orifice x x

06 0.6 mm x

08 0.8 mm x x

09 0.9 mm x

10 1.0 mm x x

11 1.1 mm x

12 1.2 mm x x

14 1.4 mm x x

15 1.5 mm x x

17 1.7 mm x

18 1.8 mm x

20 2.0 mm x x

25 2.5 mm x x

30 3.0 mm x

45 4.5 mm x

Diameter orifice d NG6 NG10

Orifice size

NG6 NG10

2-95Hydraulics

Lochbilder_gb.PM6.5MM

Directional Control ValvesMounting Patterns

Catalogue HY11-2500/UK

2

Size 6: Mounting pattern to DIN 24340-A6

Size 16: Mounting pattern to DIN 24340-A16

With * marked dimensions ± 0.1mm.All other dimensions ± 0.2mm.

Size 10: Mounting pattern to DIN 24340-A10

Subplates and manifolds see chapter 8.

2-96

Lochbilder_gb.PM6.5MM

Hydraulics

Directional Control ValvesMounting Patterns

Catalogue HY11-2500/UK

2

Size 25: Mounting pattern to DIN 24340-A25

With * marked dimensions ± 0.1mm.All other dimensions ± 0.2mm.

Size 32: Mounting pattern to DIN 24340-A32

Subplates see chapter 8.