CATALOGUE o f P r o d u c t s
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
D E V E L O P M E N T A N D P R O D U C T I O N
OF ELECTRICAL MEASURING INSTRUMENTS AND CONVERTERS
LICENSES AND CERTIFICATESJSC “Electropribor” has all the required license, certificates and assessments for the output.
Certificates of Conformity with GOST ISO 9001-2011Certificates of QMS Conformity with
GOST RV 0015-002-2012
Central Factory Laboratory Certificate for Accreditation of Industrial and Sanitary
Control Laboratory
Certificate of Test Laboratory Accreditation
License for the Right for Design of Equipment for Nuclear Plant
License for the Right for Manufacture of Equipment for
Nuclear Plant
JSC “ELECTROPRIBOR” TODAYJSC “Electropribor” is a domestic leader in the development and manufacture of the most complete range electrical panel measuring instruments, transducers, digital multimeters as well as power quality monitoring meters with functions of industrial and revenue metering.
JSC “Electropribor” started its activity from the development and manufacture of pointer measuring meters, and now it has become the industry leader in the manufacture of pointer and digital meters, measuring converters and multimeters. For 56 years of existence JSC “Electropribor” has produced more than 109 mln. pointer meters and more than 400 thous. digital meters.
The produced instruments are used for control panels of TPP, HPP and NPP, vehicle boards, as a part of weaponry board installation, household appliances, as well as in systems of LV and HV meters, relay protection and automatics. The instruments provide measurement, indication, conversion, warning and analogue/digital transmission of measured electrical parameters. Each measuring instrument of approved type is produced with the primary calibration. The calibration is carried out by the metrological service of JSC “Electropribor” accredited in accordance with Federal Law No. 412-FZ dated December 28, 2013 for the right of calibration in the national accreditation system.
While dealing with us, you and your end Customers will be provided with following:1. Certified products2. High quality, reliable and safe operation of measuring instruments3. Prompt warranty and post-warranty service4. Flexible approach to Customer’s targets, short delivery time5. Proper technical support6. Standard project support7. Financially independent and stable supplier
MANUFACTURING CAPABILITIESThe own production facilities: instrument, blank and assembly productions, availability of state-of-the-art equipment – machining centres, automatic molding machines, chip-cell surface-mounted assembly units – allow JSC “Electropribor” at its account to produce all instruments beginning from the initial cycle and finishing by shipment to the user in the shortest possible time anywhere in the country.
The plastic injection molding from thermoplastic materials(ABS, polystyrene, polyamide, polyethylene, polycarbonate, etc., including glass-filled materials)
Equipment: European automatic molding machine by Demag, Battenfeld.
Pressing of therrnosets(phenolic plastics, HM-4, rubber mixture)
Turning and milling Equipment: CNC turning machines, CNC Swiss-type screw machines, CNC milling machines.
Blanks cutting on advanced bandsaw machines
Locksmithing
FinishingDry and wet tumbling
Die stamping
Guillotine pattern cutting,DURAMA
Welding, soldering
Application of electroplating and chemical coatingsZinc-, nickel-plating, tin-bismuth alloy coating, chemical oxidation with phosphate treatment, chemical passivation
Paint coating
Stencil screen and lithographic printing
Manufacture of front panels, name plates, labels
Instrument production
Dies: blank, molding, combination and follow.
Molds: press-, vacuum-, casting.
Appliances: for machining, machine equipment, for welding.
Equipment of world manufacturers: FANUC, HAAS, Mitsubishi.
Assembly of units and finished electronic articles
PCBs mountingInstallation of output elements, SMD-mounting and PCBs lacquering
European manufacturers’ equipment: Assembleon automatic setter, visual quality inspection system MANTIS, bench for adjustment, calibration and verification, thermal acceptance test chamber.
CONTENTS
1INDEX
ELECTRICAL POINTER METERS
DCANDVOLTAGE MEASUREMENT
AC ANDVOLTAGE MEASUREMENT
POWER,FREQUENCYAND POWERFACTOR MEASUREMENT
BUDGETARY INSTRUMENTS
PORTABLEMeters
FORM OF RECORDING ACCOUNT FOR ANALOGUE METERS ............................................................................................................53
Direct current and direct voltage meters with 40х40, 60х60, 80х80 and 120х120 mm front frame ............................................................................................12Temperature, noise and radiation control meters ...............................................................16Direct current and direct voltage meters with 48х48, 72х72, 96х96 mm front frame .........................................................................................................................18DIN-rail mount meters MD42 ..............................................................................................18Meters with angular measuring mechanism ......................................................................19Meters with central measuring mechanism .......................................................................23Edgewise Direct current and direct voltage meters ............................................................26DC meters with pointer deflection angle of 240 deg. М42408, М42412, М42496.................................................................................................29Heavy-duty Direct current and direct voltage meter М42301.19 .........................................................................................................................32
AC and voltage meters with 60х60, 80х80 and 120х120 mm front frame ..........................................................................................................................34AC and voltage meters with 72х72, 96х96 mm front frame ..........................................................................................................................37DIN-rail mount meters ED42 ..............................................................................................39AC meters with pointer deflection angle of 240 deg. Ts42408, Ts42412, Ts42496 ...............................................................................................40
Panel meters for measurement of power, frequency, power factor ........................................................................................................................43
DC indicators ......................................................................................................................47Budgetary AC meter series ................................................................................................49Budgetary DC meter series ................................................................................................49Education meters................................................................................................................52
Phase sequence indicators ................................................................................................52
2 ELECTRICAL DIGITAL METERS
POWER QUALITY MONITORING METERS
PQ monitoring multimeter PQI96........................................................................................56PQ monitoring meter with functions of industrial and revenue metering PQI120C .............................................................................................................................58Portable PQM meter MPK ..................................................................................................60
AC, VOLTAGE, POWER AND FREQUENCY METERS AND INDICATION MODULES
SchM series multi-meters ...................................................................................................62Display panel ......................................................................................................................68SchP series AC, voltage and frequency meters .........................................................................................................71SchP series small AC meters .............................................................................................74SchK series AC, voltage and frequency meters .........................................................................................................77SchV series meters for measurement of one-phase mains power ..................................... 80SchCh series frequency meters .........................................................................................83SchCh series small frequency meters ................................................................................86LTC power transformers position indicators .......................................................................89
DC AND VOLTAGE METERS
Sch series meters for Direct current and direct voltage measurement and conversion ...................................................................................................................93Sch series small DC meters ...............................................................................................97Combined indication meters K02P ...................................................................................101
DISPLAY Data display Т44, Т54, Т74 ..............................................................................................103Display clock TCh44, TCh54, TCh74 ...............................................................................105
EDGEWISE METERS
Edgewise meters ..............................................................................................................107
POWER SUPPLY UNITS FOR DIGITAL METERS
Power supply units for digital meters ................................................................................ 114
KITS OF SETTING TOOLS
Kits of setting tools KSN 1, KSN 2.................................................................................... 114
NEW DECISIONS FOR APCS AND TELEMECANICS .............................................................................................................................. 115
ЭЛЕКТРОННОЕ ТАБЛО
CONTENTS
3 Measuring converters
MULTIFUNCTIONAL TRANSDUCERS Ye series multifunctional measuring converters ............................................................... 118
DC AND VOLTAGE TRANSDUCERS
Direct current and direct voltage transducers E856EL .....................................................122Direct current and direct voltage transducers E1856EL ...................................................125
AC AND VOLTAGE TRANSDUCERS
AC and voltage transducers E854EL ...............................................................................126AC and voltage transducers E1854EL .............................................................................129AC and voltage transducers EP34S .................................................................................130
AC FREQUENCY TRANSDUCERS AC FREQUENCY TRANSDUCERS E1858EL .................................................................132
4 AUXILIARY COMPONENTS
AUXILIARY COMPONENTS
Multiplying resistor ............................................................................................................134Shunts ..............................................................................................................................135Current Transformers .......................................................................................................139Adaptors and plugs...........................................................................................................141Protective caps .................................................................................................................141Sets of case parts .............................................................................................................142
TABLE OF EQUIVALENTS, DISCONTINUED AND REPLACED INSTRUMENTS OF JSC “ELECTROPRIBOR” ....................144
NOTE:
Data given in the Catalogue is of an advertising nature. Prior to operating the meters, your must study the Operation Manual.
INDEX
Type Overall dimension, mm
Description/measurand
Specifications (page)
Overall and mounting dimensions (page)
RCP Code Specifications (TU) code
PSU 96x48 Power supply unit 114 - 4230751 TU 25-7504.166-2003E849EL 161,6х105,2х62,2 Power transducer 118 121 422190 TU 25-7504.232-2016
E854EL70х86 Current and voltage
transducer126 128
422710 TU 25-7504.216-2011E856EL 122 124
E900EL 161,6х105,2х62,2 Multifunctional transducer 118 121 422190 TU 25-7504.232-2016
E1854EL24х111х116
Current and voltage transducer
129 129422710 TU 25-7504.226-2014E1856EL 125 125
E1858EL Frequency transducer 132 132ED42 53x46 mA, A, kA, V, kV 39 39 422300 TU 25-7504.177-2010
EP34S 70x86 Current and voltage transducer 130 131 422719 TU 25-7504.189-2005
K02P 96x48 mA, mV, A, V 101 102 422100 TU 25-7504.204-2008KSN - - 114 - - -Protective caps - - 141 - - -
Sets of case parts - - 142 - - -
М4247 40х21 µА 26 27 422312TU 25-7504.134-2008
М4248 54х21 µА, mA 26 27 422314М4263.8
60x60 Current indicator47 48
422313 TU 25-7504.165-2002М4263.8М 47 48М4264М
120x120mA, A, kA, V, kV 12 14 422315, 422325 TU 25-7504.132-2007
М4265М µА, mV 12 14 422315, 422326 TU 25-7504.131-2007М4272
96x96mA, A, kA, V, kV
19 20
422313, 422323
TU 25-7504.132-2007М4272.8 49 50М4273М µА, mV 19 21 TU 25-7504.131-2007М4276
72x72mA, A, kA, V, kV
19 20TU 25-7504.132-2007
М4276.8 49 50М4277М µА, mV 19 21 TU 25-7504.131-2007М4278 48x48 mA, A, kA, V, kV 19 21 TU 25-7504.132-2007М42163 60x60 Current indicator 47 47 422313 TU 25-7504.165-2002М42200 100х32
µА, mA, A, kA, V, kV26 27
422314, 422324TU 25-7504.134-2008М42201 74х26 26 27
М42243 140х42 mA 26 27 422316М42248 50x25 mA, mV, V 26 28 438140 TU 25-7504.185-2005М42300
80x80
µА, mA, А, kА, V, kV
12 13
422313, 422323TU 25-7504.132-2007
М42300.8 49 51М42301
60x6012 13
М42301.8 49 51М42301.19 32 32 422300М42303 40x40 12 14 422311, 422321М42304 80x80
µА, mV12 13
422313, 422323TU 25-7504.131-2007М42305 60x60 12 13
М42306 40x40 12 14 422311, 422321М42408 Ø85
mА, А, kА, V, kV29 30
422300 TU 25-7504.207-2009М42412 120x120 29 29М42496 96х96 29 30М42607 96x96
µА, mA, А, kA, V, kV23 24
422313, 422323TU 25-7504.132-2007М42608 72x72 23 24
М42609 48x48 23 25 422311, 422321М42610 96x96
µA, mV23 24
422313, 422323TU 25-7504.131-2007М42611 72x72 23 24
М42612 48x48 23 25 422311, 422321MD42 53x46 µА, mA, A, kA, kV, V 18 18 422300 TU 25-7504.177-2010MI120.1
120x120
P. Q. I 68 69
422953 TU 25-7504.213-2011MI120.2 U 68 69MI120.3 All parameters of
SchM120, SchM96, E900EL, etc.I; U; P; Q; S; F;сos φ; DI
68 69MI120.5 68 69MI80.3 80х80 68 70MPK - PQI parameters 60 - 422190 TU 25-7504.231-2016Adaptorsand plugs - - 141 - - -
R4201 90x180 kV 134 134 422922 TU 25-7504.115-96
INDEX
TypeOverall dimension, mm
Description/measurand
Specifications (page)
Overall and mounting dimensions (page)
RCP Code Specifications (TU) code
Т44 420х130mA, mV, V
103 104
421711 TU 25-7504.225-2014
Т54 500х170 103 104Т74 585х210 103 104TCh44 420х130 Temperature -50 °С...
+50 °С;hours 00.00 ... 23.59
105 106TCh54 500х170 105 106TCh74 585х210 105 106TOP 0,66 - 1... 2000 A 139 139 - 140 422749 TU 25-7504.178-2004UPChF-1 55x120 380/220 V, 50 Hz 52 -
422471 TU 25-7504.143-99UPChF-1М 66x100 380/220 V, 50 Hz400 V,
50 Hz 0-10 kΩ 52 -
“Education”80x120
A, V 52 -966722
TU 25-7504.2047-2004“Education-2” µА, mA, mV, V 52 - TU 25-7504.3767-79Ts42300 80x80
µA, mA, V34 35
422313, 422323 TU 25-7504.133-2007Ts42302 60x60 34 35
Ts42303
120x120
kW, MW, GW, kVAr, MVAr, GVAr 43 45 422345 TU 25-7504.164-2002
Ts42303/1 kW, MW, GW 43 45 422345 TU 25-7504.167-2003
Ts42304 45...55 Hz,450... 550 Hz 43 45422355
TU 25-7504.163-2002
Ts42305 Cos φ 43 45 TU 25-7504.171-2003Ts42306 96x96 45...55 Hz,350...450 Hz,
450...550 Hz43 44
422353 TU 25-7504.181-2005Ts42307 80x80 43 45
Ts4230896x96
kW, MW, GW, kVAr, MVAr, GVAr 43 44 422343 TU 25-7504.182-2005
Ts42308/1 kW, MW, GW 43 44 422343 TU 25-7504.190-2006Ts42309 Cos φ 43 44 422353 TU 25-7504.191-2006Ts42408 Ø85
V, kV40 41
422300 TU 25-7504.207-2009Ts42412 120х120 40 40Ts42496 96х96 40 41Ts42702 120x120 mA, V, kV 34 36 422313, 422325
TU 25-7504.133-2007Ts42703 96x96V, kV
37 38422323
Ts42704 72x72 37 38Sch00P 48×24
mA, A, mV, V
97 99
422100
TU 25-7504.228-2015Sch01P 96×24 97 99Sch02.00 96×48 97 100Sch02.01P 96×48 97 100Sch02P 96x48 93 94
TU 25-7504.218-2012Sch72P 72x72 93 94Sch96P 96x96 93 94Sch120P 120x120 93 94Sch20.1 50х25
mA, A, mV, V
107 111
438900 TU 25-7504.210-2010
Sch20.3 50х25, 25х50 107 111Sch21.1 100х25 107 112Sch21.2 100х25 107 112Sch21.3 100х25, 25х100 107 112Sch21.5 100х25 107 112Sch21.7 100х25, 25х100 107 112Sch22.1 100х50 107 112Sch22.2 100х50 107 112Sch22.4 100х50 107 112Sch22.5 100х50 107 112Sch22.6 100х50, 50х100 107 112Sch23.3 100х100 107 113Sch23.4 100х100 107 113Sch23.6 100х100 107 113Sch23.7 100х100 107 113Sch23.8 100х100 107 113SchV02.1 96x48
W, kW, MW, VAr, kVAr, MVAr
80 81
422199 TU 25-7504.217-2015SchV72.1 72х72 80 81SchV96.1 96х96 80 81SchV120.1 120х120 80 81SchК96 96x96
mA, A, kA, V, kV, Hz77 78
422100 TU 25-7504.206-2009SchК120 120x120 77 78
SchM120 120x120 29 mains param. I; U; P; Q; S; F; Cos φ
62 67422198 TU 25-7504.211.1-
2010SchM96 96х96 62 67
INDEX
Type Overall dimension, mm
Description/measurand
Specifications (page)
Overall and mounting dimensions (page)
RCP Code Specifications (TU) code
PQI96 96х96 Mains and power quality parameters 56 57
422190 TU 25-7504.227-2014PQI120C 120x120
Parameters of mains, power quality, revenue metering
58 59
SchP00P 48×24
mA, A, mV, V, kA, kV, Hz
74 76422100 TU 25-7504.228-2015SchP01P 96×24 74 76
SchP02.01P 96×48 74 76SchP02P 96х48 71 72
422100 TU 25-7504.219-2012SchP72P 72x72 71 72SchP96P 96x96 71 72SchP120P 120x120 71 72SchUP96 96x96
LTC power transformer position indicator
89 90421798
TU 25-7504.205-2008SchUP120 120x120 89 90SchUP120U 120х120 91 92 TU 25-7504.214-2011SchCh02 96x48
10...9999 Hz10...15000 Hz
83 84
422100 TU 25-7504.224-2014SchCh72 72х72 83 84SchCh96 96x96 83 84SchCh120 120x120 83 84SchCh00P 48×24×90
10...9999 Hz86 88
422100 TU 25-7504.228-2015SchCh01P 96×24×90 86 88SchCh02.01P 96×48×90 86 88E42700
80x80 mA, А, kА, V, kV34 35
422313, 422323 TU 25-7504.133-2007E42700.8 49 51E42701
60x60 А, kА, V, kV34 35
422313, 422323
TU 25-7504.133-2007
E42701.8 49 51E42702 120x120 mA, А, kА 34 36
422300E4270396x96 mA, А, kА, V, kV
37 38E42703.8 49 50E42704
72x72 А, kА37 38
422313E42704.8 49 5060ShISV.2
-
1 A... 15 A 135
135-138 422916
TU 25-7504.160-200275ShIS 20 А... 15 kА 135
TU 25-7504.175-201075ShISV 20 А... 2500 А 13575ShISV.1 10 А... 2000 А 135 TU 25-7504.162-200275ShISV.2 1 А... 15 А 135 TU 25-7504.160-2002
ELECTRICAL POINTERMETERS
12 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
PANEL DIRECT CURRENT ANDDIRECT VOLTAGE METERS
DIRECT CURRENT AND DIRECT VOLTAGE METERS OVERALL DIMENSIONS:40Х40, 60Х60, 80Х80 AND 120Х120 MM
М4230Х, М426Х
This group of meters is intended to measure current and voltage in electric DC circuits. These meters allow current measurement from 10 µА to 20 А and voltage measurement from 25 mV to 750 V using meters direct connection method. Meters М42300, М42301, М42304, М42305 can be manufactured with increased endurance to mechanical effects. When ordering, the letter (m) should be added to meter designations. Meters М42300, М42303 can withstand seismic effects equivalent to the vibration effects with acceleration in the range 1.3...15 m/s2 at frequency of 5...50 Hz in two positions.
Meters М42303 with maximum measurement ranges of 0.5 mA, 20 V and all multirange meters are manufactured with accuracy class 4 only. Meters with advanced protection may be produced according to the individual order. Housings design provides IP50 or IP54 protection level for the front side, IP00 – for the other side. Calibrated wires connecting meters with shunts are included in the set of meters delivery. The DC meters could be manufactured with the left side zero position or central-zero scales. Meter scales can be made with any units of measurement, special marks, inscriptions, etc. according to the Customers data. The standard meters position is vertical or horizontal. Taking into account the order, the meters could be manufactured with other measurement limits.
To protect personnel from contact with current carrying parts of the meters М42300, М42304, М4264М, М4265М. Supplying option for KZ-4 should be specified in the order.
Type М42303М42306
М42301М42305
М42300М42304
М4264ММ4265М
Overall dimension, mm 40х40 60х60 80х80 120х120Panel cutout, mm Ø37.5 Ø57.5 Ø77.5 112х112
Scale length, mm, min. 26 36 56 95
Accuracy class 2.5; 4.0 1.5; 2.5 1.5; 2.5 1.5; 2.5*Weight, kg, maximum 0.08 0.15 0.2 0.35* – for М4265М only
М42300, М42301, М42303
measurement range connection method operation conditionsμA – 100; 150*; 200; 300; 500; 1000
Directly
Temperature -50...+60 °Сrelative humidity 95 % at temperature +35 °С.Vibration strength:acceleration 5...30 m/s2,frequency 10...70 Hz.Impact resistance:acceleration 100 m/s2, 2000 impactswith frequency 80...120 impacts per min.For the meters with increased endurance to mechanical effects:temperature -50...+60 °Сrelative humidity 95 %at temperature of +40 °С.Vibration strength:acceleration 2...20 m/s2,frequency 10...40 Hz.Impact resistance:100 m/s2 – 88,000 impacts150 m/s2 – 20,000 impacts750 m/s2 – 2000 impactswith frequency 80...120 impacts per minute
mA – 0.5**; 1; 2.5-0-2.5**; 5; 10; 15;20; 30; 50; 100; 150; 300; 500; 600;3/30*; 3/50*; 5/50*; 30/600**mA – 50 mA/20 V**А – 1; 2; 3; 5; 10; 15*
А – 15***; 20; 30; 50; 75; 100; 150;200; 300; 500; 750; 200-0-750 With outer shunt for 75 mV and
calibrated wires of 0.035 ΩkA – 1; 1.5; 2; 4; 6
V – 0.075* With calibrated wires of 0.035 Ω
V – 1*;2; 3; 7.5; 10; 15; 20; 30; 50; 75;100; 150; 250; 300; 500; 600; 3/30*;3/300*; 30/300*; 4/100*; 7.5/300*;8/300*; 10/100*; 15/150*; 15/300*;20/40*; 0.3/15-0-0.3/15*
Directly
V** – 0.075/9; 2.5/10; 3/100; 3/300;10/300; 30/300; 6; 25; 400
V – 150/1500*; 15/150/1500*With outer multiplying resistor at rated current 5 mAkV – 1; 1.5; 3
* – For the meters М42300 and М42301 only** – For the meters М42303 only*** – For the meters М42300 only
М42304, М42305, М42306
measurement range
connection method operation conditions
μA – 5*; 10; 20; 25*; 30 Directly
Temperature -30...+50 °С, relative humidity 95 % at a temperature +35 °С. Vibration strength: acceleration 5 m/s2, frequency 50 Hz. Impact resistance: acceleration 30 m/s2, frequency of impacts 10...50 Hz per min., 2000 impacts.
μA – 50 Directly Temperature -50...+60 °С, relative humidity 95 % at temperature +35 °С. Vibration strength: acceleration 5...30 m/s2, frequency 10...70 Hz. Impact resistance: acceleration 100 m/s2, frequency of impacts 10...50 Hz per min., 2000 impacts.For the meters with increased endurance to mechanical effects:temperature -50...+60 °С, relative humidity 95 % at temperature +40 °С. Vibration strength: acceleration 2...20 m/s2, frequency 10...40 Hz. Impact resistance: 100 m/s2 – 88,000 impacts, 150 m/s2 – 20,000 impacts, 500 m/s2 – 2000 impacts with frequency 80...120 impacts per minute.
mV – 25**; 50;75; 150; 300;500; 750; 1000
With calibrated wires of 0.035 Ω
* – with the zero position inside the measurement range only** – М42304, М42305 – for accuracy class 2.5 only; М42306 – for accuracy class 4.0 only
13Catalogue of Products
www.elpribor.ru
М4264М
measurement range connection method operation conditionsmA– 0.5; 0.75; 1; 3; 5; 10; 15; 20; 30; 50; 75; 100; 150;300; 500; 600 Directly
Temperature -40...+50 °Сrelative humidity 95 % at temperature +35 °С. Vibration strength: acceleration 15 m/s2, frequency 30 Hz. Impact resistance: acceleration 70 m/s2 – 1000 impacts, frequency 10...50 impacts per minute. Vibration strength:acceleration 5 m/s2,Frequency 20 Hz – for М4264М
A – 1; 2; 3; 5; 10; 20A – 30; 50; 75; 100; 150; 200; 300; 500; 750 With outer shunt for 75 mV and calibrated wires
of 0.035 ΩkA – 1; 1.5; 2; 3; 4; 5; 6; 7.5A – 200; 400; 600
With outer shunt for 150 mV and calibrated wireskA – 1; 2; 3; 4; 6; 8; 10; 15; 20; 30V – 0.075*; 0.15*; 3; 7.5; 15; 30; 50; 75; 100; 150; 250;300; 400; 500; 600; 750 Directly
kV – 1; 1.5; 3; 10; 15 With outer multiplying resistor at rated current 5 mA
М4265МμA – 50**; 100; 200; 300; 500; 750; 1000 Directly
mV – 25**; 50; 75; 150; 300; 500; 750; 1000 With calibrated wires of 0.035 Ω
* – with calibrated wires of 0.035 Ω** – with the central zero position only
Overall and mounting dimensions
М42300, М42301, М42304, М42305
Type a b e h h1
М42300М42304
80 Ø73 Ø77.5+0.5 68 28
М42301М42305
60 Ø54.6 Ø57.5+0.4 50 20
Cutout (1:2)
2 holes
14 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
М42303, М42306
М4264М, М4265М
Cutout
Cutout
2 holes
15Catalogue of Products
www.elpribor.ru
Voltmeter М42300, 0-30 V, 1.5, vert, Б, (m), TU 25-7504.132-2007For voltmeter М42300 having measurement range 0...30 V, accuracy class 1.5, vertical operating position, dustproof and splashproof housing with increased endurance to mechanical effects.
Voltmeter М42303, 50-0-50 V, 1.5, vert, TU 25-7504.132-2007For voltmeter М42303 having measurement range 50-0-50 V, accuracy class 1.5, vertical operating position.
Voltmeter М42303 Т3, 50-0-50 V, 1.5, v, TU 25-7504.132-2007For voltmeter М42303 manufactured for operation in tropical conditions having measurement range 50-0-50 V, accuracy class 1.5, vertical operating position.
Milliampremeter М42300.х, 5-0-5 mA, scale 100-0-100%, 1.5, v, TU 25-7504.132-2007For milliammeter М42300, special design Х, rated current 5 mA, scale 100-0-100%, accuracy class 1.5, the vertical operating position.
For the meters with special marks, inscriptions, special scale graduation according to the Customer’s data, a special design number is added to a meter type after point.
For reference only:v/g – vertical/horizontal operating position; Б – dustproof and splashproof meter;(m) – meters having increased to mechanical effects; Т3 – meters for the operation in the tropical conditions;ОМ2 – meters for marine application (М42300, М42301, М42303, М4264М)
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
Ordering examples
16 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
TEMPERATURE, NOISE AND RADIATION CONTROL METERS
М42304
measurement range connection method operation conditionsμA* – 150 (10dB) Directly Temperature -50...+60 °С,
relative humidity 95 %at temperature +35 °С.Vibration strength:acceleration 2...30 m/s2,frequency 10...50 Hz.Impact resistance:acceleration 50 m/s2,frequency 10...50 impacts per min.
mV – 0-11.263** (1600 °С PR(V)) With external of 5 Ω Temperature -50...+60 °С,relative humidity 95 %at temperature +35 °С.Vibration strength:acceleration up to 5...10 m/s2,frequency 10...50 Hz.Impact resistance:acceleration 50 m/s2,frequency 10...50 impacts per min.
0-13.159** (1300 °С PP(S))
0-13.591** (1800 °С PR(V))
0-31.492 (400°C KhK(L))
0-49.108 (600 °С KhK(L))0-37.326 (900 °С KhA(K))
0-45.119 (1100 °С KhA(K))
mV – 0-49.108 (600 °С KhK(L)) With external of 15 Ω
* – the meters could be manufactured with other measurement ranges, but input current should not exceed 150 μA. ** – the meters manufactured only for operation in conditions of moderate climate and with accuracy class of 2.5 only.
М42301
measurement range connection method operation conditions
μA – 0-100 (5/150 R/h; 1/500 R/h; 100 %, empty scale)
Directly Temperature -50...+60 °С,relative humidity 98 %at temperature +35 °С.Vibration strength:acceleration up to 2...30 m/s2,frequency 10...120 Hz.Impact resistance:acceleration 100 m/s2,frequency 10...50 impacts per min.
0-150 (5/150 R/h )
V – 0-100
А – 0-10; 10-0-10
Note: meters М42301 are manufactured with accuracy class 4.0; meters with an empty scale – accuracy class 2.5.
Millivoltmeter М42304 is used to measure thermal EMF of thermocouple type KhA (K), KhK (L), PP (S), PR (D) with rated static characteristic.
Microammeter М42304 is intended for using in the noise measurement equipment. М42301 is designed for using in the special (GO-27, DP-3 Б) and other equipment. When ordering, the letter (p)* is added to meters designation. The meter has the special design with scale graduation according to the Customer’s data.
To protect personnel from contact with current carrying parts of the meters М42304. Supplying option for KZ-4 should be specified in the order.
* М42301(p) – meters with the possibility of external of the scale lighting.
М42301 (p), М42304
Overall and mounting dimensions
М42301(p)
17Catalogue of Products
www.elpribor.ru
М42304
Ordering examples
Microammeter М42301(p), 0-150 µA, scale 5/150 R/h, 4, v, TU 25-7504.132-2007For microammeter М42301, design with the possibility of external scale lighting (p), rated current of 150 µA, scale 5/150 R/h, accuracy class 4, the vertical operating position.
Millivoltmeter М42304, 0...31.488 mV, scale 0...400 °С KhK (L), 1.5, v, TU 25-7504.131-2007For millivoltmeter М42304, with rated value of 31.488 mV, with scale of 0-400 °С KhK (L), accuracy class 1.5, the vertical operating position.
For reference only:v/g - vertical/horizontal operating position;Б – dustproof and splashproof meter;(m) – increased endurance to mechanical effects;(p) – the design with the possibility of external scale lighting.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
Type a b e h h1
М42304 80 Ø73 Ø77.5+0.5 68 28
Cutout (1:2)
2 holes
Cutout (1:2)
2 holes
18 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Direct current and direct voltage METERS WITH48Х48, 72Х72, 96Х96 MM FRONT FRAME
DIN-RAIL MOUNT METERS MD42
MD42
Meter MD42 is mounted on the DIN-rail of 35 mm in width EN 50022
The measuring mechanism location in meters is angular
Front panel dimensions, mm, min. – 42.
Accuracy class – 1.5. Weight, kg, max. – 0.25.
This group of meters are manufactured with the following designs: square /round base, DIN-rail mount meters EN50022 with 35 mm in width.It allows the Customer to replace instruments purchased in foreign companies with ones produced by JSC “Electropribor”, or to replace domestic instruments
having the cases with round bases and square front frames with ones of dimensions according to DIN43718.
Overall and mounting dimensions
Ordering examples
MD42
measurement range connection method operation conditionsμA – 100; 150; 250; 400; 600
Directly Temperature -30...+50 °С, relative humidity 90 % at temperature +30 °С. Vibration strength:acceleration up to 20 m/s2, frequency 10...55 Hz. Impact resistance: acceleration up to 150 m/s2, number of impacts 18
mA– 1; 1.5; 2.5; 4; 5; 6; 10; 15; 20; 25; 40; 60; 100; 150; 250; 400; 600А – 1; 1.5; 2.5; 4; 6; 10; 20А – 1; 1.5; 2.5; 4; 6; 10; 15; 25; 40; 60; 100; 150; 250; 400; 600 With outer measuring shunt for 60
mV or 75 mV and calibrated wires of 0.035 ΩkA – 1; 1.5; 2.5; 4; 6; 10; 15
mV – 60; 100; 150; 250; 400; 600DirectlyV – 1; 1.5; 2.5; 4; 6; 10; 15; 25; 40;
60; 100; 150; 250; 300; 400; 500; 600
Ammeter МD42, 0-1 A, 1.5, v, TU 25-7504.177-2010For ammeter МD42 manufactured for operation in conditions of moderate climate, having measurement range 0-1 A, accuracy class 1.5; vertical operating position.
Voltmeter МD42 Т3, 1-0-1 V, 1.5, g, TU 25-7504.177-2010For voltmeter МD42 manufactured for operation in tropical conditions, having measurement range 1-0-1 V, accuracy class 1.5, horizontal operating position.
For reference only:v/g - vertical/horizontal operating position;Т3 – meters for the operation in the tropical conditions.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
19Catalogue of Products
www.elpribor.ru
Meters with angular measuring mechanism
М427Х М4272, М4276, М4278
measurement range connection method operation conditionsmA– 0.5; 1; 1.5; 2.5;3; 4; 5; 6; 10; 15; 20; 25; 30; 40; 50; 60; 100; 150; 250; 300; 400; 500; 600 Directly
Temperature -30...+50 °С. relative humidity 90 % at temperature +30 °С.Vibration strength:acceleration 5...30 m/s2.frequency 10...70 Hz.Impact resistance:acceleration 50 m/s2.frequency 10...50 impacts per min.. 2000 impacts.
А – 1; 1.5; 2; 2.5; 3; 4; 5; 6; 10*А – 10**; 15; 20; 25; 30 40; 50; 60; 75; 100; 150; 200; 250; 300; 400; 500; 600; 750
With outer shunt for 75 mV and calibrated wires of 0.035 Ω
kA – 1; 1.5; 2.5; 4; 6; 10; 15А – 200; 600 With outer shunt for 150 mV and
calibrated wires of 0.035 ΩkA – 1; 2; 3; 4; 5; 6; 8; 10; 15; 20; 30
V – 1; 1.5; 2.5; 4; 6; 10; 15; 25; 40; 60; 100; 150; 250; 300; 400; 500; 600 Directly
kV – 1; 1.5; 2.5; 3; 4; 6*; 10; 15 With outer multiplying resistor at rated current of 1 mA
* – for М4272 and М4276 only** – for М4278 only
М4273М, М4277М
measurement range connection method operation conditionsμA – 40; 60; 100; 150; 250; 400; 600 Directly Temperature -30...+50 °С,
relative humidity 95 % at temperature +35 °С.Vibration strength:acceleration 5...30 m/s2,frequency 10...70 Hz.Impact resistance:acceleration 50 m/s2,frequency 10...50 impacts per min.
mV – 25; 40; 60; 100; 150; 250; 400; 600 With calibrated wires of 0.035 Ω
М4272(с), М4276(с)
measurement range connection method operation conditionsmA – 1; 1.5; 2.5; 4; 5; 6; 10; 15; 20; 25; 40; 50; 60; 100; 150; 250; 400; 600 Directly
Temperature -30...+50 °С. relative humidity 80 % at temperature +25 °С.Vibration strength:acceleration 5...30 m/s2.frequency 10...70 Hz.Impact resistance:acceleration 50 m/s2.frequency 10...50 impacts per min.
А – 1; 1.5; 2.5; 4; 6; 10; 15А – 1; 1.5. 2; 2.5; 3; 4; 5; 6; 7.5; 10; 15;25; 40; 60; 100; 150; 200; 250; 400; 600 With outer calibrated shunt for
60 mV and calibrated wires of 0.035 ΩkA – 1; 1.5; 2.5; 4; 6; 10; 15
А – 1; 1.5; 2; 2.5; 3; 4; 5; 6; 7.5; 10; 15; 20; 30; 50; 75; 100; 150; 200; 300; 500; 750
With outer calibrated shunt for 75 mV and calibrated wires of 0.035 Ω
kA – 1; 1.5; 2; 3; 4; 5; 6; 7.5V – 1; 1.5; 2.5; 4; 6; 10; 15; 25; 40; 60;100; 150; 250; 300; 400; 500; 600 Directly
kV – 1; 1.5; 3; 5; 7.5; 10; 15 With multiplying resistor at rated current 5 mA
kV – 1; 2.5; 4; 5; 6; 10; 15 With multiplying resistor at rated current of 1 mA
Type М4278 М4276М4277М
М4272М4273М
Overall dimension, mm 48х48 72х72 96х96
Panel cutout, mm 44.8х44.8 68х68 92х92
Scale length, mm, min. 38 57 93
Accuracy class 1.5 1.5 1.5Weight, kg, maximum 0.12 0.2 0.28
These types of meters are provided with square front frames and square cases with angular location of the measuring mechanism.
Meters М4272, М4276 are manufactured with replaceable scales. When ordering, the letter (s) is added to meter designations.
To protect against contact with current-carrying rods, since 2017 meters М4276, М4277М, М4272, М4273М, М4276(s), М4272(s) may be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.
20 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
М4272, М4276
Type a b e
М4272 96 90.6 92+0.8
М4276 72 67.5 68+0.7
Type a b e
М4272 96 91.5 92+0.8
М4276 72 67.5 68+0.7
Cutout
Cutout
М4272, М4276 with replaceable scales
21Catalogue of Products
www.elpribor.ru
М4273М, М4277М
М4278
Type Dimensions, mm
a b e L1 L2 L3 d
М4273М 96 90.6 92+0.8 50 35 8 М4М4277М 72 67.5 68+0.7 50 35 8 М4
Cutout
Cutout
22 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
Ammeter М4272.1, 0...1 A, 1.5, g, TU 25-7504.132-2007For ammeter М4272 having measurement range 0...1 A, accuracy class 1.5, horizontal operating position, dust-proof design with the special scale.
Ammeter М4272.1 Т3, 0...1 A, 1.5, g, TU 25-7504.132-2007For ammeter М4272 manufactured for operation in tropical conditions having measurement range 0...1 A, accuracy class 1.5, horizontal operating position, dust-proof design with the special scale.
Ammeter М4272(s), 20-0-20 А, 75 mV, 1.5, v, TU 25-7504.132-2007For ammeter М4272 with the replaceable scale, measurement range is 20-0-20 А with connection via the outer shunt for 75 mV, accuracy class 1.5, the vertical operating position.
For reference only:v/g – vertical/horizontal operating position; Б – dustproof and splashproof meter;Т3 – operation in the tropical conditions; (s) – replaceable scale design;ОМ2 – meters for marine application (except for М4272(s), М4276(s), М4273М, М4277М).
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
23Catalogue of Products
www.elpribor.ru
М426ХХМ42607, М42608, М42609
measurement range connection method operation conditionsμA* – 100; 200; 300; 500; 1000mA– 1; 5; 10; 15; 30; 50; 100; 150;300; 500; 600 Directly Temperature -30...+50 °С,
relative humidity 90 % at temperature +30 °С.Vibration strength:acceleration 5...30 m/s2,frequency 10...70 Hz.Impact resistance:acceleration 50 m/s2,frequency 10...50 impacts per min.
А – 1; 2; 3; 5; 10; 15**А – 20; 30; 50; 75; 100; 150; 200; 300;400; 500; 750 With outer shunt for 75 mV and
calibrated wires of 0.035 ΩkA – 1; 1.5; 2; 4; 6V – 2; 3; 7.5; 10; 15; 20; 30; 50; 75;100; 150; 250; 300; 400; 500; 600 Directly
kV – 1; 1.5; 3 With an individual multiplying resistor at rated current 5 mA
М42611, М42612
measurement range connection method operation conditionsμA – 25***; 30***; 50
Directly
Temperature -30...+50 °С, relative humidity 95 % at temperature +35 °С.Vibration strength:acceleration 5...30 m/s2,frequency 10...70 Hz.Impact resistance:acceleration 50 m/s2,frequency 10...50 impacts per min.
М42610μA – 50***; 100; 200; 300; 500; 1000
М42610, М42611, М42612
mV – 25; 50; 75; 150; 300; 500; 750; 1000 With calibrated wires of 0.035 Ω
* – For the meters М42608, М42609 only** – For the meters М42607, М42608 only*** – with the centre-zero position (measurement range) only
Type М42609М42612
М42608М42611
М42607М42610
Overall dimension, mm 48х48 72х72 96х96
Panel cutout, mm Ø42.5 68х68 92х92
Scale length, mm, min. 32 50 76
Accuracy class 1.5; 2.5 1.5; 2.5 1.5; 2.5
Weight, kg, maximum 0.12 0.15 0.2
Meter types М42609, М42612 are intended for installation in panels with round cutouts, meter types М42607, М42608, М42610, М42611 are intended for installation in panels with square cutouts.
The measuring mechanism location in these meters is central.
To protect against contact with current-carrying rods, meters М42608, М42611, М42607, М42610 may be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.
METERS WITH CENTRALMEASURING MECHANISM
24 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
М42608, М42611, М42607, М42610
TypeDimensions, mm
a b e f h1 L1 L2 L3 d
М4260872 67.5 68+0.7 75
28 50 35 8 М4М42611М42607
96 90.6 92+0.8 100М42610
Cutout Rear view
25Catalogue of Products
www.elpribor.ru
М42609, М42612
Ordering example
Voltmeter М42607, 0...30 V, 1.5, v, TU 25-7504.132-2007For voltmeter М42607 having measurement range 0...30 V, accuracy class 1.5, vertical operating position.
For reference only:v/g – vertical/horizontal operating position; Б – dustproof and splashproof meter;Т3 – meters for the operation in the tropical conditions;ОМ2 – meters for marine application (М42609, М42608, М42607).
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
Type Dimensions, mm
A B a b D D1 d
М4260948 37±0.45 12±0.2 16±0.2 41 42.5+0.6 4,5М42612
Cutout2 holes d
26 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
М42243
М4220Х
М4247, М4248
М42248
This group of meters contains DC ammeters and voltmeters, which are used in switchboards, tile control panels and small equipment.
These meters could be manufactured for horizontal or vertical mounting with the relative location of the meter scale.
The protection level that is provided by cases of meters М4247, М4248 corresponds to IP53, meters 42248 – to IP20, other types of meters – to IP50. The protection level of live outputs is IP00.
Type М4247 М42248 М4248 М42201 М42200 М42243Overall dimension, mm 40х21 50х25 54х21 74х26 100х32 140х42
Panel cutout, mm 30.5х21 46.5х21.5 40.5х21 60.5х24.5 80.5х28.5 115х37Scale length, mm, min. 20 27 27 40 60 94
Accuracy class 4.0 2.5 2.5; 4.0 1.5; 2.5 1.5*; 2.5 1.0
Weight, kg, maximum 0.035 0.08 0.04 0.20 0.25 0.5
* - except for μA
Edgewise direct current and direct voltage meters
М42243
measurement range connection method operation conditions
mA– 5; 20 Directly
Temperature -50...+60 °С, relative humidity 95 % at temperature +35 °С.Vibration strength:acceleration 2...15 m/s2,frequency 10...70 Hz.Shock resistance:acceleration 50 m/s2,frequency 10...50 impacts per min.
М42200, М42201
measurement range connection method operation conditionsμА – 100; 150; 200; 250; 300; 400;500; 600; 750; 1000
Directly
Temperature -50...+60 °С, relative humidity 95 % at temperature +35 °С.Vibration strength:acceleration 5...20 m/s2,frequency 10...120 Hz.Vibration strength:acceleration 5...30 m/s2,frequency 10...120 Hz.Shock resistance:acceleration 30 m/s2,frequency 10...50 impacts per min.Impact resistance:acceleration 100 m/s2,frequency 10...50 impacts per min.
mA– 1; 5; 10; 15; 30; 50; 100; 150;300; 500; 600А – 1; 2; 3; 5; 10А – 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 1000; 1500; 2000; 3000; 4000; 6000
With outer shunt of 75 mV and calibrated wires of 0.035 Ω
А – 7500; 10000; 12500; 15000 With outer shunt of 100 mV and calibrated wires of 0.035 Ω
V – 2; 3; 7,5; 10; 15; 30; 50; 75; 100; 150; 250; 300; 450; 500; 600 Directly
V – 1000; 1500; 3000 With outer multiplying resistor at rated current 5 mA
М4247, М4248
measurement range connection method operation conditionsμА – 50*; 75*; 100; 150; 200; 250;300; 400; 500; 600; 1000
Directly
Temperature -50...+60 °С, relative humidity 95 % at temperature +35 °С.Impact resistance:acceleration 100 m/s2,frequency 10...50 impacts per min.
mA– 5**
* – with the zero position inside the measurement range only** – for М4248 only
27Catalogue of Products
www.elpribor.ru
Overall and mounting dimensions
М4247, М4248, М42200, М42201, М42243
Type Dimensions, mm Panel cutouts AA1 A2 V С D1 D2 d E1 E2
М4247 40 20.5 42 11 30.5 21 2.4 34 -Fig. 1
М4248 54 20.5 45.6 12.4 40.5 21 3.4 46 -М42200 100 32 85.8 20.2 80.5 30.5 4.5 90 20
Fig. 2М42201 74 26 84.5 16.5 60.5 24.5 3.4 67 16М42243 140 42 115 25 115 37 4.5 128 28 Fig. 3
М42248 is the meter with increased endurance to mechanical effects intended for operation under conditions of NPP
measurement range connection method operation conditionsmA– 5; 20; 4-20 Directly Temperature -10...+45 °С, relative humidity 98 % at temperature +35 °С.
Vibration strength: within the frequency range 5 to 30 Hz with acceleration of 40 m/s2; within the frequency range 30 to 150 Hz with acceleration of 9.8 m/s2.Vibration strength: within the frequency range 5 to 100 Hz with acceleration of 80 m/s2.Impact resistance: pulse duration 2...20 ms with acceleration of 200 m/s2.6000 impacts.
mV – 75; 200V – 1; 10; 2-10
Panel cutouts
Fig. 1
Fig. 2
Fig. 3
28 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
М42248
Ordering examples
Milliammeter М42243, 0...10 kGs/см², 1.5, v, TU 25-7504.134-2008For milliammeter М42243 manufactured for operation in conditions of moderate climate with the dust-proof scale design of 0...10 kGs/cm2, accuracy class 1.5; vertical operating position.
Milliammeter М42243 Т3, 0...10 kGs/см², 1.5, v, TU 25-7504.134-2008For milliammeter М42243 manufactured meters for the operation in the tropical conditions with the dust-proof scale design of 0...10 kGs/cm2, accuracy class 1.5; vertical operating position.
Microammeter М42201(p), 100-0-100 µA, 1.5, v, TU 25-7504.134-2008For microammeter М42201 manufactured for operation in conditions of moderate climate, having measurement range 100-0-100 µA, accuracy class 1.5, vertical operating position, dust-proof design.
Microammeter М4248, 0...100 µA, 2.5, v, Б, TU 25-7504.134-2008For microammeter М4248 manufactured for operation in conditions of moderate climate, having measurement range 0...100 µA, accuracy class 2.5, vertical operating position, dust-proof design.
Microammeter М4247.1 TU 25-7504.134-2008For microammeter М4247 with the special scale.
Microammeter М42248, 4...20 mA, 0...10 MPa, v – black, TU 25-7504.185-2005For milliammeter М42248 with rated current of 4 to 20 mA, scale 0...10 MPa, the vertical operating position, black case.
For reference only:v/g – vertical/horizontal operating position;Т3 – meters for the operation in the tropical conditions.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
* size 80 max without sizes of socket BL 3.5/4F.
Socket
29Catalogue of Products
www.elpribor.ru
Overall and mounting dimensions
М42412
М42496
М42412
М42408
The meters are intended to measure current and voltage in DC and pulse current circuits at 100 Hz in different spheres of industry and on railway transport. The meters are made in a plastic case and are vibration and shock resistant. All М42408 designs are provided with dial lighting.
Type М42408 М42412 М42496
Overall dimension, mm Ø 85 120х120 96х96
Scale length, mm 127 200 150Panel cutout, mm 82 112х112 92х92Accuracy class 1.5 1.5 1.5
Case protection level (for the front frame) IP53 IP53 IP53
Meter weight, kg 0.32 0.4 0.36
DC meters with pointer deflection angleof 240 deg.
М42408, М42412, М42496
end value of a measurements range connection method operation conditions
Cutout
mA– 1; 5; 20А – 5; 10 Directly Temperature -50...+60 °С
Relative humidity 95 % at +35 °С.Vibration strength: acceleration 10 m/s2,frequency 10...100 Hz.Impact resistance: acceleration 30 m/s2,duration 6...20 ms
А – 10; 20; 30; 50; 75; 100; 150; 200; 300; 400; 500; 600; 750kA – 1; 1.5; 2; 3; 4; 5; 6; 7.5; 10
With outer shunt for 75 mV and calibrated wires of 0.035 Ω
V – 10; 15; 30; 50; 100; 150; 250 Directly
kV – 1; 1.5; 2; 3; 4 With outer multiplying resistor at rated current of 1 mA
Ammeters can be graduated for operation with connecting wires of 0.053; 0.088; 0.14 and 0.21 Ω. In accordance with the Customer’s option ammeters can be graduated for operation with connecting wires of other resistance but not more than 0.28 Ω.
30 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
М42408
М42496
Cutout
Cutout
2 ro
ds
2 ro
ds2
rods
31Catalogue of Products
www.elpribor.ru
Ordering examples
Ammeter М42408, 0...1 A, 0...75 mV; v, TU 25-7504.207-2009For ammeter М42408 having measurement range 0...10 A and outer shunt for 75 mV; accuracy class 1.5, vertical operating position.
Ammeter М42408 ОМ2, 0...10 A, 0...75 mV, 1.5, g, TU 25-7504.207-2009For ammeter М42408 having measurement range 0...10 A and outer shunt for 75 mV; accuracy class 1.5, vertical operating position, meters for marine application.
Voltmeter М42408, 30-0-30 V, 1.5; v, TU 25-7504.207-2009For voltmeter М42408 having measurement range 30-0-30 V, accuracy class 1.5, vertical operating position.
For reference only:v/g – vertical/horizontal operating position; ОМ2 – meters for marine application.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
32 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
М42301.19Meter М42301.19 is manufactured
with increased endurance to mechanical effects. When ordering, the letter (m) is added to the meter designation.
The meter М42301.19 measuring mechanism is secured on rubber shock absorbers to provide resistance to mechanical effects (impacts, vibration). The meter case is made of high-strength material “Celanex” and resistant to oil, gasoline, etc.
Heavy-duty direct current and direct voltage meter М42301.19
measurement range connection method operation conditionsµA – 100; 150; 200; 300; 500; 1000
Directly
For the meters with increased endurance to mechanical effects: temperature -50...+80 °С. relative humidity 98 % at temperature +40 °С.Vibration strength:acceleration 30 m/s2.frequency 10...50 Hz.Impact resistance:100 m/s2 – 88.000 impacts.150 m/s2 – 20.000 impacts.500 m/s2 – 2000 impacts. with frequency 80...120 impacts per min.Vibration strength:acceleration 2...20 m/s2.frequency 10...40 Hz
mA –1; 5; 10; 15; 20; 30; 50; 100; 150; 300; 500; 600А – 1; 2; 3; 5; 10А – 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 200-0-750 With outer shunt for 75 mV and
calibrated wires of 0.035 ΩkA – 1; 1.5; 2; 4; 6
V – 0.075 With calibrated wires of 0.035 Ω
V – 1; 2; 3; 7.5; 10; 15; 20; 30; 50; 75; 100; 150; 250; 300; 500; 600 Directly
kV – 1; 1.5; 3 With outer multiplying resistor at rated current 5 mA
М42301.19Overall dimension, mm 60х60Panel cutout, mm Ø57.5Scale length, mm, min. 42Accuracy class 2.5Weight, kg, maximum 0.15Design Dust-drop-proof
Cutout
4 holes
33Catalogue of Products
www.elpribor.ru
Ordering example
Microammeter М42301.19, 0...100 µA, scale 0...1.0, 2.5, v, g, (m) TU 25-7504.1324-2007For microammeter М42301.19, rated value 100 µA, scale 0...1.0, accuracy class 2.5, the standard operating position is v, g, with advance mechanical characteristics.
For reference only:v/g – vertical/horizontal operating position;(m) – for the design with increased endurance to mechanical effects.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
34 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Panel AC and voltage meters are manufactured of two types:
– magnet-moving coil system with rectifier;
– electromagnetic system;These meters allow current
measuring within 25 µА...100 А and voltage 0.5 V...750 V with their direct switching on. To extend a measurement range: by current – current transformers type TOP-0.66 are used, by voltage – voltage transformers.
Ammeters and voltmeters are made with the zero-scale at the range edge. The meters can be made with any scales of any units of measurement according to Customer’s request.
For structural design, the AC meters are divided into two groups:
– meters with square front frames and round cases.
– meters with square front frames and square cases. The protection level for the front frame is IP50 or IP54, protection level for current-carrying rods – IP00.
To protect against contact with current-carrying rods, meters E42700, E42702 (ammeters up to 10 A, milliammeters, voltmeters, meters with actuation via current/voltage transformers), Ts42300, Ts42702 may be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.
TypeTs42302 E42701 Ts42300 E42700 Ts42702 E42702
Overall dimension, mm 60х60 60х60 80х80 80х80 120х120 120х120
Panel cutout, mm Ø57.5 Ø57.5 Ø77.5 Ø77.5 112х112 112х112Scale length, mm, min. 44 44 65 65 90 90
Accuracy classµА – 1.5; 2.5 А – 1.5; 2.5
2.5А – 1.5; 2.5
1.5 1.5mA. V – 2.5 V – 2.5 V – 2.5
Weight, kg, maximum 0.12 0.2 0.14 0.35 0.35 0.45
Meters with 60х60, 80х80 and 120х120 mm front frame
Ts42300, Ts42302µA – 25*; 50; 100; 200; 300; 500
Directly
Temperature -30...+50 °С for mill- and microammeters. -50...+60 °С for voltmeters;relative humidity 95 % at temperature 35 °С.Standard frequency range is 45...1000 Hz.Operating frequency range is 30-45..... 1000-20000 Hz for mill- and microammeters;30-45..... 1000-10.000 Hz for voltmeters.Vibration strength: acceleration 5...30 m/s2. frequency 10...70 Hz.Impact resistance: acceleration 70 m/s2. frequency is 10...50 impacts per min.. 2000 impacts
mA – 1; 5; 10; 15; 10-30; 15-50; 30-100; 50-150; 100-300; 150-500; 300-1000
V – 0.5-3; 1-7.5; 2-15; 30; 50; 75; 150; 250; 300; 500; 600
* – for microammeter Ts42302 only
Ts42702
end value of a measurements range
transformation ratio
connection method operation conditions
mA– 10; 20; 30; 50; 100;250; 500
Directly
Temperature -40...+50 °С. relative humidity 95 % at temperature 35 °С.Standard frequency range is 50...1000 Hz.Vibration strength: acceleration 5 m/s2. frequency 20 Hz.Vibration strength: acceleration 15 m/s2. frequency 30 Hz.Impact resistance: acceleration 70 m/s2. frequency is 10...50 impacts per min.. 1000 impacts
V – 15; 30; 50; 75; 100; 150; 250; 300; 400; 500; 600
V – 450; 500; 600; 750
0-450V 380/1000-500V 500/1000-600V 500/1000-750V 750/100
Via a voltage transformer with secondary voltage of 100 VkV – 3.5; 4; 6; 7.5; 12.5; 15;
17.5; 20; 25; 40; 125; 150;175; 200; 250; 400; 600
0...3.5kV 3000/1000...4kV 4000/1000...6kV 6000/1000...7.5kV 6000/1000...12.5kV 10000/1000...15kV 13800/1000...17.5kV 15750/1000...20kV 18000/1000...25kV 20000/1000...40kV 35000/1000...125kV 110000/1000...150kV 150000/1000...175kV 150000/1000...200kV 200000/1000...250kV 220000/1000...400kV 330000/1000...600kV 500000/100
PANEL AC AND VOLTAGEMETERS
35Catalogue of Products
www.elpribor.ru
Overall and mounting dimensions
Ts42302, E42701, Ts42300, E42700
E42702
measurement range connection method operation conditionsmA – 100; 250; 400; 600 Directly Temperature -40...+50 °С, relative
humidity 95 % at temperature +35 °С.Vibration strength: acceleration 5 m/s2, frequency 20 Hz.Vibration strength: acceleration 15 m/s2, frequency 30 Hz.Impact resistance: acceleration 70 m/s2, frequency is 10...50 impacts per min.Standard frequency and frequency range:45-65; 50; 60; 200; 500; 1000 Hz
А – 1; 1.5; 2; 2.5; 3; 4; 5; 6; 10; 20; 30; 50; 100*А – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400; 500; 600; 750; 800 Via a current transformer with
secondary current of 1 or 5 AkA – 1; 1.2; 1.5; 2; 3; 4; 5; 6; 8; 10; 20; 30; 40E42702 – overload ammeter (overload factor – 2)А – 1; 1.5; 2.5; 3; 4; 5; 6; 10; 15; 20; 30; 50; 100* DirectlyА – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400 Via a current transformer with
secondary current of 1 or 5 AkA – 0.5; 0.6; 0.8; 1; 1.5; 2; 3; 4; 5; 6; 10; 20; 30; 40
E42702 – overload ammeter (overload factor – 5 or 6)A – 1; 3; 5; 10 DirectlyА – 1; 10 Via a current transformer with
secondary current of 1 AA – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150 Via a current transformer with
secondary current of 5 AkA – 0.2; 0.25; 0.3; 0.4; 0.5; 0.6; 0.75; 0.8; 1; 1.5; 2; 3; 4; 5; 6; 8; 10* – for standard frequency and frequency range, Hz 45-55, 50.
E42700, E42701mA* – 100; 250; 400; 600
DirectlyTemperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.Vibration strength: acceleration 5...30 m/s2, frequency 10...70 Hz.Impact resistance: acceleration 70 m/s2, frequency is 10...50 impacts per min.Standard frequency and frequency range:45-65; 50,180-550; 60; 180-550; 800;1000 Hz (for ammeters); 45-65; 50; 60; 200; 400;500; 800; 1000 Hz (for voltmeters)
А – 1; 1.5; 2; 2.5; 3; 4; 5; 6; 10; 20; 30; 50; 100*А – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400; 500; 600; 750; 800 Via a current transformer with
secondary current of 1* or 5 AkA – 1; 1.2;1.5; 2; 3; 4; 5; 6; 8; 10; 20; 30; 40V – 10; 30; 50; 100; 150; 250; 400; 500; 600; 750 DirectlyV – 400; 450; 500; 600; 750
Via a voltage transformer with secondary voltage of 100 VkV* – 3.5; 4; 6; 7.5; 12.5; 15; 17.5; 20; 25; 40; 125; 150; 175; 200; 250; 400; 600
* – for E42700 onlyFor the meters E42700 with the upper limit of measurement range 100 A with direct actuation at standard frequency of 50 Hz and frequency range 45...65 Hz only.For the meters E42700, E42701, E42702, Ts42702, the transformer primary current and voltage is the same as the upper limit of measurement range.For voltmeter Ts42702, the transformer primary voltage is the same as data given in the table.Note: ammeters E42700 may be manufactured with overload factor 2.Meters manufacture is possible with other measurement ranges and for actuation via a current transformer with the secondary current of 1 A.
Type Dimensions, mm
A V С D D1 d E b
Ts42302
6035
11
54.6 57.5 3.4 50М4
E42701
20...50 A, direct actuation 37 М6
Ts42300
80
35
73 77.5 3.4 68
М4E4270020...50 A, direct actuation 37 М6
100 A, direct actuation 42 М8
Cutout
2 holes
36 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ts42702, E42702
Ordering examples
Ammeter E42702, 20 А; 20/5, 50, v, TU 25-7504.133-2007For ammeter E42702 manufactured for operation in conditions of moderate climate, with the upper measurement range 20 A, actuation via a current transformer with the secondary current of 5 A, vertical operating position, for standard frequency of 50 Hz.
The same is for an overload ammeter E42702 (overload factor – 5) with the upper value of the overload section of 100 A:Ammeter E42702, 20...100 А; 20/5, 50, v, TU 25-7504.133-2007
The same is for an ammeter manufactured in the tropical conditions:Ammeter E42702 Т3, 20...100 А; 20/5, 50, v, TU 25-7504.133-2007
For reference only:v/g – vertical/horizontal operating position; Б – dustproof and splashproof meter;ОМ2 – meters for marine application.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
Type Dimensions, mm
A B C D b
Ts42702
120
35
8 111.4
М4E42702
20...50 A, direct actuation 37 М6
100 A, direct actuation 42 М8
Cutout
37Catalogue of Products
www.elpribor.ru
E4270Х, Ts4270Х
Overall and mounting dimensions correspond to the European standards. The mechanism location is angular.
To protect against contact with current-carrying rods, meters E42704, E42702 (ammeters up to 10 A, ammeters with actuation via current transformers), E42703 (ammeters up to 10 A, milliammeters, voltmeters, meters with actuation via current/voltage transformers), Ts42704, Ts42703 may be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.
Type E42704 Ts42704 E42703 Ts42703
Overall dimension, mm 72х72 72х72 96х96 96х96
Panel cutout, mm 68х68 68х68 92х92 92х92
Scale length, mm, min. 60 60 95 95
Accuracy class 1.5 1.5 1.5 1.5Weight, kg, maximum 0.35 0.25 0.35 0.3
Meters with 72х72, 96х96 mm front frame
Ts42703, Ts42704
end value of a measurements range
transformation ratio connection method operation
conditionsV – 15; 30; 50; 75; 100; 150; 250; 300; 400; 500; 600 - Directly
Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.Vibration strength:acceleration 15 m/s2,frequency 30 Hz.Vibration strength:acceleration 5 m/s2,frequency 20 Hz.Impact resistance:acceleration 70 m/s2, frequency 10...50 impacts per min.Standard frequency and frequency range for E42703, E42704 – 45...65, 50, 60, 200, 500, 1000 Hz;for Ts42703, Ts42704 – 50...1000 Hz
V – 400; 450; 500; 600; 750 0...400V ... 380/1000...450V ... 380/1000...500V ... 500/1000...600V ... 500/1000...750V ... 750/1000...3.5kV ... 3000/1000...4kV ... 3000/1000...6kV ... 6000/1000...7.5kV ... 6000/1000...12.5kV ... 10000/1000...15kV ... 13800/1000...17.5kV ... 15750/1000...20kV ... 18000/1000...25kV ... 20000/1000...40kV ... 35000/1000...125kV ... 110000/1000...150kV ... 150000/1000...175kV ... 150000/1000...200kV ... 200000/1000...250kV ... 220000/1000...400kV ... 330000/1000...600kV ... 500000/100
kV – 3.5; 4; 6; 7.5; 12.5; 15; 17.5; 20; 25; 40; 125; 150; 175; 200; 250; 400; 600
Via a voltage transformer with secondary voltage of 100 V
E42703, E42704mA* – 100; 250; 400; 600 Directly
А – 1; 1.5; 2; 2.5; 3; 4; 5; 6; 10; 20; 30; 50; 100*
А – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400; 500; 600; 750; 800 Via a current transformer
with secondary current of 1* or 5 AkA – 1; 1.2; 1.5; 2; 3; 4; 5; 6; 8;10; 20; 30; 40
E42703
V – 10; 30; 50; 100; 150; 250; 400; 500; 600; 750 Directly
V – 400; 450; 500; 600; 750 Via a voltage transformer with secondary voltage of 100 V
kV – 3.5; 4; 6; 7.5; 12.5; 15; 17.5; 20; 25; 40; 125; 150; 175; 200; 250; 400; 600
E42703, E42704 – overload ammeter(overload factor – 2)А – 1*; 1.5*; 2.5*; 3*; 4*; 5; 6*; 10* ;15*; 20*; 30*; 50*; 100* Directly
А – 5*; 10*; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250*; 300; 400kA – 0.5; 0.6; 0.8; 1;1.5; 2; 3*; 4; 5*; 6*; 10*; 20*; 30*; 40*
Via a current transformer with secondary current of 1 or 5 A
* – for E42703 onlyFor the meters E42703 (for the end measurement range 100 A with direct actuation at standard frequency and frequency range only, Hz 45...65; 50).
Note: meters manufacture is possible with other measurement ranges and for actuation via a current transformer with the secondary current of 1 A.
38 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
Ordering examples
Voltmeter Ts42703, 600 V, 50, v, TU 25-7504.133-2007For voltmeter Ts42703 manufactured for operation in conditions of moderate climate, with the upper measurement range 600 V for standard frequency of 50 Hz, vertical operating position.
Voltmeter Ts42703 , 3.5 kV, 3000/100, v, TU 25-7504.132-2007For voltmeter Ts42703 manufactured for operation in conditions of moderate climate, with the upper measurement range 3.5 kV, actuation via a voltage transformer with the primary voltage of 3000 V and secondary voltage of 100 V, vertical operating position.
Ammeter E42703 ОМ2, 20 А; 50, v, TU 25-7504.133-2007For ammeter E42703 with the upper measurement range 20 A, vertical operating position, for standard frequency of 50 Hz and operation on marine vessels.
For reference only:v/g – vertical/horizontal operating position; Б – dustproof and splashproof meter;ОМ2 – meters for marine application.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
Type Dimensions, mm
A B C D D1 d
E42704
72
35
8 67.5 68
М4
20...50 A, direct actuation 37 М6
Ts42704 35 М4E42703
96
35
8 90.6 92
М420...50 A, direct actuation 37 М6100 A, direct actuation 42 М8
Ts42703 35 М4
CutoutRear view
39Catalogue of Products
www.elpribor.ru
Overall and mounting dimensions
Ordering examples
Ammeter ED42, 500 А; 500/5, 1.5, v, TU 25-7504.177-2010For ammeter ED42 manufactured for operation in conditions of moderate climate, with the upper measurement range 500 A, actuation via a current transformer with the secondary current of 5 A, accuracy class 1.5 and vertical operating position.
Voltmeter ED42 Т3, 4 kV; 3000/100; 1.5, v, TU 25-7504.177-2010For voltmeter ED42 manufactured meters for the operation in the tropical conditions, with the upper measurement range 4 kV, actuation via a voltage transformer with the primary voltage of 3000 V and secondary voltage of 100 V, accuracy class 1.5 and vertical operating position.
For reference only:v/g – vertical/horizontal operating position.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
ED42
Meters ED42 are designed for mount on DIN-rail with 35 mm in width, EN 50022.
The measuring mechanism location in these meters is angular.
Overall dimension, mm – 53х46.Scale length, mm, min. 42. Accuracy
class 1.5.Weight, kg, max. 0.25.
DIN-rail mount meters ED42
ED42
measurement range connection method operation conditionsmA– 100; 150; 250; 400; 600 Directly Temperature -40...+50 °С, relative
humidity 90 % at temperature +30 °С.Vibration strength:acceleration up to 20 m/s2,frequency 10...55 Hz.Impact resistance:acceleration up to 150 m/s2,number of impacts 18
A – 1; 1.5; 2.5; 4; 5; 6; 10; 20A – 1; 1.5; 2.5; 4; 5; 6; 10; 15; 20; 30; 40; 50; 60; 80; 100; 150; 200; 300; 400; 500; 600
Via a current transformer with the secondary current of 1 or 5 A
kA – 1; 1.2; 1.5; 2; 3; 4; 5; 6; 8; 10V – 6; 10; 15; 25; 40; 60; 100; 150;250; 400; 500; 600
Directly
kV – 4; 6; 8; 10; 15; 20; 40; 60; 150;250; 400
Via a voltage transformer with secondary voltage of 100 V
Note: ammeters ED42 may be manufactured with overload factor – 2.
40 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
Ts42412
Ts42408
Ts42412
Ts42496
The meters are intended to measure current and voltage in AC mains, one-phase AC circuits 50 Hz in different spheres of industry and on railway transport. The meters are made in a plastic case and are vibration and shock resistant. All Ts42408 designs are provided with dial lighting.
Type Ts42408 Ts42412 Ts42496
Overall dimension, mm Ø 85 120х120 96х96
Scale length, mm 127 200 150
Panel cutout, mm Ø 81 112х112 92х92
Accuracy class 2.5 1.5 2.5
Case protection level (for the front frame) IP53 IP53 IP53
Meter weight, kg 0.32 0.4 0.36
Meters with pointer deflection angle of 240 deg.
Ts42408, Ts42412, Ts42496
finite range connection method operation conditions
V – 10; 20; 30; 50; 75; 100; 150; 250; 300; 400 Directly
Temperature -50...+60 °С.Relative humidity 95 % at temperature +35 °С.Vibration strength: acceleration 10 m/s2, frequency 10...100 Hz.Impact resistance: acceleration 30 m/s2, duration 6...20 ms
kV – 1; 1.5; 2; 3; 4; 7.5; 10; 12; 15; 30
Via a voltage transformer with secondary voltage of 100 V
kV 30
Via a voltage transformer with the secondary voltage of 100 V, transformation factor of 25,000/100 V
For the meters Ts42408, Ts42412, Ts42496, the transformer primary voltage is the same as the upper limit of measurement range.
Cutout
41Catalogue of Products
www.elpribor.ru
Ts42496
Ts42408
Cutout
Cutout
2 ro
ds
2 ro
ds
2 ro
ds
42 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
Voltmeter Ts42408, 0-100 V, 1.5; v, TU 25-7504.207-2009For voltmeter Ts42408 having measurement range 0-100 V, accuracy class 1.5, vertical operating position.
Voltmeter Ts42408, 0-3 kV, 3000/100, 1.5; g, TU 25-7504.207-2009For voltmeter Ts42408 having measurement range 0...3 kV, actuation via a voltage transformer with the primary voltage of 3000 V and secondary voltage of 100 V, accuracy class 1.5 and horizontal operating position.
For reference only:v/g – vertical/horizontal operating position;Б – dustproof and splashproof meter.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
43Catalogue of Products
www.elpribor.ru
Wattmeters and varmeters Ts42303, Ts42308 are intended for measurement of active or reactive power in three-phase three-wire AC circuits of 50...60 Hz at uniform or non-uniform phase load. Wattmeters Ts42303/1, Ts42308/1 are intended for measurement of active power in one-phase AC circuits of 50, 60, 500, 1000 Hz.
Frequency meters Ts42304, Ts42306, Ts42307 are intended for measurement of AC frequency.
Power factor meters Ts42305 and Ts42309 are intended for measurement of power factor in in three-phase three-wire AC circuits of 50 Hz with symmetry of line voltage and balanced phase load.
The meters are made based on an electronic converter of input signal into DC signal and a moving-coil meter arranged in one case.
Type Ts42307 Ts42308 Ts42306 Ts42303 Ts42303/1
measurand HzkW, MW, GW, kVAr, MVAr, GVAr
HzkW, MW, GW, kVAr, MVAr, GVAr
kW, MW, GW,
Overall dimension, mm 80х80 96х96 96х96 120х120 120х120
Panel cutout, mm Ø77.5 92х92 92х92 112х112 112х112
Scale length, mm, min. 65 97 97 94 94
Accuracy class 1.0 1.5 1.0 1.5 1.5Weight, kg, maximum 0.25 0.7 0.4 0.9 0.75
Type Ts42304 Ts42305 Ts42308/1 Ts42309
measurand Hz cosφ kW. MW. GW. cosφ
Overall dimension. mm 120х120 120х120 96х96 96х96
Panel cutout. mm 112х112 112х112 92х92 92х92
Scale length. mm. min. 94 94 97 97
Accuracy class 0.5 2.5 1.5 2.5Weight. kg. maximum 0.65 0.75 0.65 0.6
PANEL METERS FOR MEASUREMENT OF POWER, FREQUENCY, POWER FACTOR
Overall view of meters with 80х80, 120х120 mm front frame
Overall view of meters with 96х96 mm front frame
Ts42303, Ts42308 (3-phase mains); Ts42303/1, Ts42308/1 (1-phase mains)
power factor rated voltage, V rated current, A
connection method
operation conditions
For wattmeter cosφ=1For wattmeter sinφ=1
127220230*380400*
5 DirectlyTemperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.Impact resistance:acceleration 70 m/s2, frequency 10...50 impacts per min.Vibration strength:acceleration 15 m/s2, frequency 30 Hz
1; 5 Via a current transformer
100 1; 5 Via a current/voltage transformer
* – for Ts42308
When ordering wattmeters and varmeters, the following parameters shall be indicated:1) current transformation factor;2) voltage transformation factor;3) frequency of 50 Hz or 60 Hz;4) balanced or unbalanced load.
44 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
Ts42306, Ts42308, Ts42308/1, Ts42309
Ts42304, Ts42306, Ts42307
measurement range rated voltage, V connection method operation conditions
45...55 Hz 450...550 Hz350...450 Hz*
127220380230*400*
Directly Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.Impact resistance: acceleration 70 m/s2, frequency is 10...50 impacts per min.Vibration strength: acceleration 15 m/s2, frequency 30 Hz.
100 Via a voltage transformer
* – for Ts42306, Ts42307
Ts42305, Ts42309
measurement range rated voltage, V rated current, А connection
method operation conditions
0.5-1-0.50.9-1-0.2
127220380
5 Directly
Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.Impact resistance: acceleration 70 m/s2, frequency 10...50 impacts per min. Vibration strength: acceleration 15 m/s2, frequency 30 Hz100
1; 5 Via a current/voltage transformer
When ordering the power factor meter, the following shall be given:1) meter type;2) measurement range;3) rated voltage and current;4) standard frequency;5) specifications designation.
Cutout
Screw M3
45Catalogue of Products
www.elpribor.ru
Ts42307
Ts42303, Ts42303/1, Ts42304, Ts42305
Cutout
Cutout
2 bo
lts
46 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
Wattmeter Ts42303, 220 V, 5 А, 50 Hz, S, TU 25-7504.190-2002For wattmeter Ts42303 for rated voltage 220 V, rated current 5 A, standard frequency 50 Hz and balanced load. The same is for a wattmeter manufactured in general climatic conditions:Wattmeter Ts42303 О4.1, 220 V, 5 А, 50 Hz, S, TU 25-7504.164-2002
Wattmeter Ts42303, 10,000/100, 5000/5, 50 Hz, TU 25-7504.164-2002For wattmeter Ts42303 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz and unbalanced load.
Wattmeter Ts42303/1, 220 V, 5 А, 50 Hz, TU 25-7504.167-2003For wattmeter Ts42303/1 for rated voltage 220 V, rated current 5 A, standard frequency 50 Hz. The same is for a wattmeter manufactured for operation in general climatic conditions:Wattmeter Ts42303/1 О4.1, 220 V, 5 А, 50 Hz, TU 25-7504.167-2003
Wattmeter Ts42303/1, 10,000/5, 5000/5 А, 50 Hz, TU 25-7504.167-2003For wattmeter Ts42303/1 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz.
Frequency meter Ts42304, 45...55 Hz, 220 V, v, TU 25-7504.163-2002For frequency meter Ts42304 having measurement range 45...55 Hz for rated voltage 220 V, vertical operating position. The same is for a frequency meter manufactured for operation in general climatic conditions: Frequency meter Ts42304 О4.1, 45...55 Hz, 220 V, g, TU 25-7504.163-2002
Ts42305, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.171-2003For power factor meter Ts42305 having measurement range 0.5-1-0.5, for rated voltage 220 V, rated current 5 A and standard frequency 50 Hz.The same is for a power factor meter manufactured in general climatic conditions:Ts42305 О4.1, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.171-2003
Frequency meter Ts42306, 45...55 Hz; 220 V, TU 25-7504.181-2005For frequency meter Ts42306 having measurement range 45...55 Hz for rated voltage 220 V.The same is for frequency meter Ts42306 manufactured for operation in general climatic conditions:Frequency meter Ts42306 О4.1, 45...55 Hz; 220 V, TU 25-7504.181-2005The same is for a frequency meter manufactured meters for marine application:Frequency meter Ts42306 ОМ2, 45...55 Hz; 220 V, TU 25-7504.181-2005
Wattmeter Ts42308, 220 V, 5 А, 50 Hz, S, TU 25-7504.182-2005For wattmeter Ts42308 for rated voltage 220 V, rated current 5 A, standard frequency 50 Hz and balanced load. The same is for a wattmeter manufactured for operation in general climatic conditions:Wattmeter Ts42308 О4.1, 220 V, 5 А, 50 Hz, S, TU 25-7504.182-2005The same is for a wattmeter manufactured meters for marine application:Wattmeter Ts42308 ОМ2, 220 V, 5 А, 50 Hz, S, TU 25-7504.182-2005
Wattmeter Ts42308, 1000/100, 5000/5, 50 Hz, TU 25-7504.182-2005For wattmeter Ts42308 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz and unbalanced load.
Wattmeter Ts42308/1, 220 V, 5 А, 50 Hz, TU 25-7504.190-2006For wattmeter Ts42308/1, rated voltage 220 V, rated current 5 A, standard frequency 50 Hz. The same is for a wattmeter manufactured for operation in general climatic conditions:Wattmeter Ts42308/1, О4.1, 220 V, 5 А, 50 Hz, TU 25-7504.190-2006
Wattmeter Ts42308/1, 10,000/100, 5000/5, 50 Hz, TU 25-7504.190-2006For wattmeter Ts42308/1 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz.
Ts42309, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.191-2006For power factor meter Ts42309 having measurement range 0.5-1-0.5, for rated voltage 220 V, rated current 5 A and standard frequency 50 Hz.The same is for a power factor meter manufactured in general climatic conditions:Ts42309, О4.1, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.191-2006
For reference only:v/g – vertical/horizontal operating position;О4.1 – for operation in general climatic conditions;ОМ2 – meters for marine application (Ts42307, Ts42306, Ts42308).
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
47Catalogue of Products
www.elpribor.ru
Overall and mounting dimensions
М42163
М42163, М4263.8,М4263.8М
The indicators are intended for measurement of current in chargers and other DC meters in different branches of industry in conditions of moderate climate.
The М4263.8 and М4263.8М measuring mechanism is of a moving-coil system with fastening mobile part with pivots. М42163 and М4263.8М are manufactured without sealing.
Type М4263.8 М4263.8М М42163
Overall dimension, mm 60х60 60х60 60х60
Panel cutout, mm Ø 57.5 Ø 57.5 Ø 57.5
Scale length, mm 42 42 42
Basic error, % ± 10 ± 10 ± 10
Mass, kg 0.105 0.105 0.03
DС indicators
М4263.8, М4263.8М, М42163
measurement range connection method operation conditions
А – 7.5; 10 DirectlyFor М4263.8, temperature -50...+60 °С, relative humidity 95 % at temperature +35 °С.Vibration- and shock-resistant.For М4263.8М and М42163, temperature -30...+50 °С, relative humidity 90 % at temperature 25 °С.Vertical operating position
А – 30* With outer shunt for 75 mV and calibrated wires of 0.035 Ω
* – for М4263.8 only
BUDGETARY INSTRUMENTS
Cutout
2 holes
48 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
М4263.8, М4263.8М
Ordering examples
Current indicators М4263.8, 0...10 А, TU 25-7504.165-2002For current indicator М4263.8 having measurement range 0...10 A.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
Cutout
49Catalogue of Products
www.elpribor.ru
E4270Х.8
The meters are intended for measurement of current in chargers and other DC meters in different branches of industry in conditions of moderate climate.
To protect against contact with current-carrying rods, meters could be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.
The meters are intended to measure current and voltage in AC mains, and they are used in different spheres of industry.
To protect against contact with current-carrying rods, meters could be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.
М4230Х.8, М427Х.8
Type E42700.8 E42701.8 E42703.8 E42704.8Overall dimension, mm 80х80 60х60 96х96 72х72
Panel cutout, mm Ø 77.5 Ø 57.5 92х92 68х68
Scale length, mm 65 44 95 60
Basic error, % ± 4.0 ± 4.0 ± 4.0 ± 4.0
Mass, kg 0.35 0.2 0.35 0.35
Type М42300.8 М42301.8 М4272.8 М4276.8Overall dimension, mm 80х80 60х60 96х96 72х72
Panel cutout, mm Ø 77.5 Ø 57.5 92х92 68х68
Scale length, mm 60 42 93 57
Basic error, % ± 4.0 ± 4.0 ± 4.0 ± 4.0
Mass, kg 0.2 0.15 0.2 0.15
Budgetary AC meter series
Budgetary DC meter series
М42300.8, М42301.8, М4272.8, М4276.8
measurement range connection method operation conditionsА – 30; 50; 75; 100; 150; 300; 500;750;
With outer shunt for 75 mV and calibrated wires of 0.035 Ω
IP40 – level of protection against environment effect.Temperature -30...+50 °С, relative humidity 90 % at temperature +30 °С.Vibration strength:acceleration 5...30 m/s2,frequency 10...70 Hz,Impact resistance:for М42300.8, М42301.8:acceleration 100 m/s2, 2000 impacts;for М4272.8, М4276.8:acceleration 50 m/s2, 2000 impacts.
kА – 1.5; 3
The meters could be manufactured with other measurement limits.
E42700.8, E42701.8, E42703.8, E42704.8
measurement range connection method operation conditions
A: 10; 30; 50; 75; 100; 150; 200; 250;300; 400; 600; 800kА:1.5; 2; 3V: 500 (except for E42704.8)
via a current transformer with the secondary current of 5 A
IP40 – level of protection against environment effect.Temperature -40 °С... +50 °С, relative humidity 95 % at temperature +35 °С.Vibration strength: acceleration 5...30 m/s2, frequency 10...70 Hz.Impact resistance: acceleration 70 m/s2 – 2000 impacts, frequency 10...50 impacts per minute.
Meters manufacture is possible with other measurement ranges and for actuation via a current transformer of 1 A.
50 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
М4272.8, E42703.8, М4276.8, E42704.8
Type Dimensions, mm
a b e h1 l1 l2 l3 d
М4276.8, E42704.8 72 67.5 68 28 50 35 8 М4
М4272.8, E42703.8 96 90.6 92 28 50 35 8 М4
Cutout
51Catalogue of Products
www.elpribor.ru
Cutout 2 holes
М42300.8, E42700.8, М42301.8, E42701.8
Ordering examples
Ammeter М42300.8, 0...30 А, 4.0 TU 25-7504.132-2007For ammeter М42300.8 having measurement range 0...30 A, accuracy class 4.0.
The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».
TypeDimensions, mm
a b e h h1 l1 l2 l3 dМ42300.8, E42700.8
80 Ø73 Ø77.5 68 28 50 35 11 М4
М42301.8, E42701.8
60 Ø54.6 Ø57.5 50 20 50 35 11 М4
52 Electrical pointer meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Laboratory ammeters and voltmeters type “Education”
measurement range connection method operation conditions
А 1; 2; 5; 10V 6; 15; 30
DirectlyTemperature +10...+35 °С, relative humidity 80 % at temperature +30 °С
Laboratory microammeters, millammeters, millivoltmeters and voltmeters, type “Education 2”
measurement range connection method operation conditionsμA – 20/100-0-100/500 (М42174)mА – 0-5/50 (Ts42170)mА – 1/10-0-5/50 (М42170)mА – 5/10-0-5/50 (М42170.1)mV – 10/50-0-50/250 (М42171)V – 0,1/0,3-0-0,5/1,5 (М42172)V – 3/10-0-15/50 (М42173)
DirectlyTemperature +10...+35 °С, relative humidity 80 % at temperature +30 °С
measurement range operation conditions
UPChF-1
Temperature -30...+50 °С, relative humidity 90 % at temperature +25 °С. The indicator operation mode is short-term.
V – 380/220 – 50 Hz
UPChF-1MV – 380/220 – 50 HzV – 400 – 50 Hz “~”kΩ – 0...10 “-”
EDUCATION METERS
Phase sequence indicators
UPChF-1, UPChF-1М
Indicators UPChF-1 and UPChF-1М are intended to determine direct and reverse phase sequence in 3-phase AC electrical circuit with grounded neutral of rated voltage 380/200 V, 50 Hz. In addition to determination of phase sequence, Indicator UPChF-1M is intended to measure voltage in AC circuits and resistance.
They are used in laboratories of schools, vocational training schools, colleges and other educational institutions. The meters are intended to measure current and voltage in 50 Hz DC and AC circuits. The meters can be made with any scales of any units of measurement according to Customer’s request. Overall dimensions of education meters – 80х120х53 mm, weight – 0.2 kg. Meters accuracy class is 2.5 and 4.0.
PORTABLE Meters
Ordering example
Ammeter “Education” 0...10 А, 2.5 TU 25-7504.2047– 2004For ammeter “Education” manufactured for operation in conditions of moderate climate, having measurement range 0...10 A, accuracy class 2.5.
Ordering examples
Indicator UPChF-1, TU 25-7504.143-99Indicator UPChF-1M, TU 25-7504.143-99
These instruments may be used during mounting of phase-dependent 3-ph electrical receivers, electric motors, pumps, machine tools, 3-ph residual current circuit breakers and other loads, as well as during adjustment and repair.
53Catalogue of Products
www.elpribor.ru
Form of recording account for analogue meters
Meter
Type
No. of custom-designed meter
Environment protection design
Structural design
Unit of measurement
Meter rated value
Measurement range or upper limit of measurement range, or scale parameters (for custom designs)
Transformation factor (for AC meters connected via current or voltage transformers)
Frequency and frequency range
Accuracy class
Standard meter position
Climatic meter design
Acceptance type
Reference symbol
The following abbreviations are used:
Environment protection design:
Structural design:
Standard meter position:
(for edgewise meters)
Climatic meter design:
Acceptance type:
Reference symbol:
dust-proof design – not specifieddustproof and splashproof meter (IP54 on the front frame) – Bdesign meters for marine application – ОМ2
design with increased endurance to mechanical effects – mdesign with the possibility of external scale lighting - preplaceable scale design – s
vertical – Vhorizontal – Gthe meter operates in two positions – V, Ghorizontal operating position – ХХG (for example, 45G)the meter is installed vertically, the horizontal scale – Pthe meter is installed vertically, the vertical scale – Yethe meter is installed horizontally, the horizontal scale – Lthe meter is installed horizontally, the vertical scale – Kthe meter is installed at the angle of 45 deg. to the horizon, the horizontal scale - Ithe meter is installed at the angle of 45 deg. to the horizon, the vertical scale - Dat an angle to the horizon – ХХG (for example, 12G)the meter operates in two positions – M
Industrial model – Otropical model – TKexport model – EK
without acceptance by the military representative office – Owith acceptance by the military representative office – P
verification officer’s stamp on the meter glass – PK meters with serial numbers (customized) – Nmeters manufactured for NPP – A
2 ELECTRICALDIGITALMETERS
56 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
POWER QUALITY MONITORINGMETERS
Power quality analyzer
PQI96
PQI96 is a modern digital measurement instrument, providing accurate three-phase measurements of AC electrical quantities. It also enables power quality assessment according to present standards.
The Power Quality Analyzer PQI96 is intended for continuous measurements of electrical power and power quality parameters in three-phase AC networks. It can be used to control the conformity of power quality with EN50160 norms.
FeaturesMultifunctionality. Device carries
out measurements of harmonics, interharmonics, unbalance, flicker, active, reactive and apparent powers, phase angles of fundamental and harmonic components and much more.
High accuracy and standard compliance. All power quality measurements are made according to IEC 61000-4-30 ed.2 Class A. Harmonic and interharmonic components are measured according to IEC 61000-4-7 Class I. Flicker is measured according to IEC 61000-4-15 Class F3.
Very compact form-factor (96 x 96 x 75 mm) enables fast and easy installation into distributing panels.
Increased LED indicator height (25 mm)provides comfortable local meter readings.
Ethernet based synchronization (NTP/PTP) does not require additional synchronization circuits and is accurate up to ±1µs.
Competitive price compared to existing power quality instruments.
Type Dimensions, mm Weight, kg, max
PQI96 96 х 96 х 77 0,7
Main parametersMeasurements rated voltage: 57,73 (100) or 230 (400) V
rated current: 1 or 5 А
current/voltage measurement frequency: 42.5...57.5 Hz
Communication ports Ethernet (10/100 BASE TХ or 100 BASE FX), EIA RS485
Type of display 7-digit LED (3 lines of 4 digits), digit height 20 mm and 14 mm
Temperature range (operating) from -40˚С to +55˚С, ANSI/IEC 60529 IP51
Electromagnetic compatibility According to GOST R 51317.6.5, ISCRI 22 for Class A
Effective voltage and current values;Active/reactive/full power;Reduction of active/reactive/full power;Voltage and current angular curves.
According to GOST R 8.655
Power supply from 90 to 264 V AC, (50 ± 0.5) Hz or from 130 to 370 V DC
Calibration interval 10 years
Guarantee period 36 months
PQI parameters
Power quality measurements Power frequencyVoltage and current magnitudesFlicker perceptibilityDips, swells, interruptionsVoltage unbalanceVoltage harmonicsVoltage interharmonicsUnder- and overdeviationRelative phase anglesActive, reactive, apparent powersActive and reactive energies
Power quality: IEC 61000-4-30 : Class AHarmonics and Interharmonics: IEC 61000-4-7 : Class IFlicker: IEC 61000-4-15 : Class F3
Metrological characteristics According to GOST 30804.4.30-2013, GOST 32144-2013, GOST R 51317.4.15-2012, GOST 30804.4.7-2013, GOST R 8.655-2009 (power quality)
57Catalogue of Products
www.elpribor.ru
Order form
PQI96 – b – с – d – e – f – g – h – i
b – rated voltage:– line voltage – 100 V, 400 V;– transformation ratio of voltage (rated secondary voltage value is 100 V);
c – rated current:– phase current – 1.0 А; 5.0 А;– transformation ratio of current (nominal secondary current value is 1 A, 5 A);
d – the type of the main Ethernet interface:– 1REО – an interface Ethernet («optics», «Optics»);– 1REC – an interface Ethernet («copper», «twisted pair»);
е – the symbol of the presence of an additional interface RS485 (only for the device having option REC):- RS - RS485 interface is available;- x - RS485 interface is not available;
f – symbol of the measuring circuit:- 3W - for three-wire connection scheme,- 4W - for four-wire connection scheme;
g – color of the indicators:– R – red indicators,– G – green indicators,– Y – yellow indicators;
h – temperature range (operating):– (-40...+55° C);
i – special version:– otherwise, this parameter is not specified
Ordering example
Overall dimensions
PQI96 – 100V – 1А – 1RЕС– х – 3W – R – (-40...+55° C) TU 25-7504.227-2014PQI96 with the following characteristics: rated voltage of 100 V, rated current of 1.0 А, interface Ethernet (“copper”), three-wire connection scheme, red indicators, for operation at temperature of minus 40 to plus 55 °С.
Connection diagrams
InterfacesRemote HMI and Control HTTP (WEB interface)
Communication protocols IEC 60870-5-104 (Ethernet),IEC 60870-5-101 (EIA RS-485),IEC 61850-8-1
Integration in power quality indices (PQI) control system
HTTP (integration in PQI visualization and monitoring software package supplied in completion with the meter)
Synchronization NTP (RFC 5905), PTP (IEEE 1588)
Three phase four-wire three-element connection using 3 CT and 3 VT
Three phase four-wire two-element connection using 2 CT and 2 VT
UpwrUpwr
Power supply Power supplyPQI96 PQI96
58 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Multifunctional revenue energy meter and power quality analyzer
Type Dimensions, mm Weight, kg, max
PQI120C 120 х 120 х 75 0.7
PQI120C
PQI120C is designed for revenue metering, measurement of power quality index (PQI), parameters of current, voltage, power, active and reactive power in 3ph mains and AC systems, as well as in points of meters mounting while keeping measurement results and displaying parameters of accounted electric power, PQI parameters and subsequent data transmission via communication interfaces.
PQI120C is installed in the power quality monitoring and control systems for continuous monitoring of power quality indices of substations.
Power Quality Measurement and Monitoring (Class A):
– rms voltage;– frequency;– duration and index of ACF and
overvoltage;– temporary overvoltage duration;– long- and short-term flicker indicator;– temporary overvoltage factor;– voltage n-harmonic component
factor;– voltage waveform distortion factor;– negative-sequence voltage factor;– zero-sequence voltage factor.Multifunctional power meter (Class
0.2S):– metering of consumed active power
based on cumulative total and separately according to rates;
– eight rates;– active and reactive power;– active and reactive power loss;– energy recording malfunction flags.
Main parametersrated voltage 100 V or 400 V
rated current 1 А or 5 А
Temperature range (operating) from -40 °С to +55 °С
Dust/moisture protection IP51, GOST 14254
Resistance to mechanical effects Group 4 according to GOST 22261
Electromagnetic compatibility Interference immunity: GOST R 51317.6.5;Electromagnetic emission: ISCRI 22 for Class A
Calibration interval 10 years
Guarantee period 36 months
Power Supply
Power supply voltage from 90 to 264 V AC, (50 ± 0.5) Hz or from 130 to 370 V DC
Power consumption 5 VA
Interfaces
Communication protocols Ethernet 10/100 BASE TX (RJ45 connector) (2 ports) or Ethernet 100 BASE FX (ST connector) (2 ports), RS485, fiber optic port - IEC 61107, test pulse output, IEC 61850-8-1
Type of display 3 units of 7-segment indicators (4 indicators per each unit)
Remote HMI and Control HTTP (WEB interface)
Integration in telemetry systems IEC 60870-5-104 (Ethernet channel),IEC 60870-5-101 (EIA RS-485 channel),IEC 61850-8-1,Optical interface “optical port” (IEC 61107), pulse output interface
Integration in power quality indices (PQI) control system
HTTP (integration in PQI visualization and monitoring software package supplied in completion with the meter)
Integration in automated power supply monitoring and control system
Enlargement of IEC 60870-5-101/104, IEC 61850-8-1
Synchronization NTP (RFC 5905)/PTP (IEEE `1588)
Total compliance with the Russian standardsPower quality: GOST 30804.4.30-2013, GOST 32144-2013, GOST R 51317.4.15-2012, GOST 30804.4.7-2013, GOST R 8.655-2009Revenue metering: GOST 31819.22-2012 (class 0.2S)GOST 31819.23-2012 (class 1)Mains parameters measurement: GOST 22261-94, GOST R 52931-2008, GOST 29322-92.
59Catalogue of Products
www.elpribor.ru
Ordering exampleOrder form
Overall dimensions
PQI120C – 400V – 5А – 2RЕО – 2RS – 4W – R – (-40...+55° C) TU 25-7504.227 2014PQI120C with the following characteristics: dimensions of 120х120 mm, rated voltage of 400 V, rated current of 5.0 А, two interfaces Ethernet (“optics”), two interfaces RS485, four-wire measurement design, red indicators, for operation at temperature of minus 40 to plus 55 °С.
PQI120C – b – с – d – e – f – g – h
b – rated voltage:– line voltage – 100 V, 400 V;– transformation ratio of voltage (rated secondary voltage value is 100 V);
c – rated current:– phase current – 1.0 А; 5.0 А;– transformation ratio of current (nominal secondary current value is 1 A, 5 A);
d – the type of the main Ethernet interface:– 2REО – an interface Ethernet («optics», «Optics»);– 2REC – an interface Ethernet («copper», «twisted pair»);
е – the symbol of the presence of an additional interface RS485:– 2RS – availability of two interfaces RS485;
f – symbol of the measuring circuit:- 3W - for three-wire connection scheme,- 4W - for four-wire connection scheme;
g – indicators colour:– R – red indicators,– G – green indicators,– Y – yellow indicators,
h – temperature range (operating):– (-40...+55° C);
Connection diagrams
Three phase four-wire three-element connection using 3 CT and 3 VT
Three phase four-wire two-element connection using 2 CT and 2 VT
Upwr1 – main power supply source voltage of the meterUpwr2 – voltage of standby/auxiliary power supply source
Upwr1 (Upwr2)Upwr1 (Upwr2)
PQI120C PQI120CRESERVE RESERVE
LineLi
ne
Load
Load
60 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Portable power quality analyzer
MPK
The MPK1 meter is designed to measure power quality indices (voltage parameters) in three-phase, three-wire and three-phase, four-wire AC mains and systems, as well as in points for mounting power quality indices meters (PQIM) of substations, power quality monitoring and control systems (PQ MCS) of PJSC FGC UES while keeping measurement results according to the preset algorithms within the time periods counted by the real-time clock. Additionally, the meter is used to ensure the power quality indices compliance with the quality standards in general power supply systems of default voltages according to GOST 29322-2014 (IEC 38-83), 50 Hz, and optional PQI (voltage parameters) display (off-display option is allowed) as decimal numbers, and to transmit indices in a digital code through interfaces RS485 and Ethernet.
The MPK1 meter is a power quality continuous monitoring meter functioning as PQIM (voltage parameters measurement), and it is intended for long-term measurements including performance of diagnostic and research works.
Main parameters
Measurements rated voltage: 57,73 (100) or 230 (400) V
rated current: 1 or 5 А
current/voltage measurement frequency: 42.5...57.5 Hz
Communication interface Ethernet (“optics” or “copper”); RS485
Temperature range (operating)
From -40 to +55 °С
Protection extent IP 50
Electromagnetic compatibility
According to the requirements specified in ISCRI 22 for equipment class “A”
Power supply voltage from 90 to 264 VAC, (50 ± 0.5) Hz or from 130 to 370 VDC
Calibration interval 10 years
Guarantee period 24 months
PQI parameters
Measurement of power quality indices
According to the requirements of GOST 30804.4.30-2013, GOST 30804.4.7-2013, GOST R 51317.4.15-2012, GOST R 8.655-2009, GOST 32144-2013, GOST 29322-2014, GOST 31819.23-2012, GOST 31819.22-2012Measurements:– mean square value of phase, line-to-line voltage, U– frequency, f– voltage n-harmonic component factor, КU(n)
– voltage waveform distortion factor, КU
– negative-sequence voltage factor, К2U
– zero-sequence voltage factor, К0U
– ACF duration, Δtn
– ACF depth, δUn
– voltage interruption duration, Δtinter
– temporary overvoltage duration, Δtov.volt U
– temporary overvoltage factor, Kov.volt U
– short-term flicker indicator, PSt
– long-term flicker indicator, PLt
Metrological characteristics According to GOST 30804.4.30-2013 (Class А), GOST 32144-2013
Interfaces parameters
Remote HMI and Control HTTP (WEB interface)
Integration in telemetry systems
IEC 60870-5-104 (Ethernet), IEC 60870-5-101 (EIA RS485) IEC 61850-8-1 (Ethernet)
Synchronization NTP (RFC 5905), PTP (IEEE 1588)
61Catalogue of Products
www.elpribor.ru
Ordering examplesOrder form
The delivery set comprises the following:
MPK1 – 100V – REO – x – x TU 25-7504.231-2016For MPK meter with the following characteristics: input parameter – rated voltage of 100 V, interface Ethernet (“optics”).
MPK1 – 400V – REС – RS – x TU 25-7504.231-2016For MPK meter with the following characteristics: input parameter – rated voltage of 400 V, interface Ethernet (“copper”), interface RS485.
MPKa – b – с – d – e – f
а – input measured parameters:1 – voltage meter;
b – rated values of measured parameters:– 100 V, 400 V – line voltage or U/100 – voltage transformation factor (rated secondary winding voltage: 100 V);
c – reference designation of main interface Ethernet:REО – availability of interface Ethernet (“optics”);REC – availability of interface Ethernet (“copper”);
d – reference designation for availability of interface RS485 (only for REC meters):х – specified with no interface RS485;RS – availability of interface RS485;
е – availability of indicators:х – indicator-free design (basic design);
f – special version:– otherwise, this parameter is not specified.
1. MPK meter;2. Case;3. Wires with clamps to connect input signals;4. Power cable;5. Operation Manual and Calibration Method for a batch of up to 10 pcs.;6. Record.
62 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
AC, VOLTAGE AND FREQUENCY METERS AND TRANSDUCERS
MULTIFUNCTION DIGITAL PANEL METERS
Type Overall dimensions, mm Sign height, mm Weight, kg, maximum
SchM96 96 х 96 х 75,6 20 0,5
SchM120 120 х 120 х 75,6 25 0,9
SchM96, SchM120SchM96, SchM120 is designed for
measurement of electric parameters of 3 or 4-wire three-phase an alternating current by frequency of 45-55 Hz with symmetric and asymmetrical loading.
Devices are used in systems of data gathering for transfer of results of measurement to systems of top level or as the universal measuring device, instead of di$erent electric devices: ampermeters, voltmeters, wattmeters, varimeters, frequency counter. In devices possibility is provided:
-Reprogramming of display ranges;-Set value min and max within a
measurement range;-Regulation of brightness of indication;-Connections of external modules of
indication.
Measured and calculated parameters
Basic error, % Designation
Measured parametersSchM96, SchM120
SchM96PQ, SchM120PQ
Phase voltage RMS ±0,2 UA, UB, UC + -
Average voltage RMS ±0,2 Uav.ph + -
Phase-to-phase voltage RMS ±0,2 UAB, UBC,UCA + -
Average effective line-to-line voltage value
±0,2 Uav.l + -
Effective phase current value ±0,2 IA, IB, IC + -
Average effective phase current value
±0,2 Iav. + -
Active load phase power ±0,5 РA, РB, РC + +
Total active power ±0,5 Р + +
Reactive load phase power ±0,5 QA, QB, QC + +
Total reactive power ±0,5 Q + +
Full load phase power ±0,5 SA, SB, SC + +
Total gross reactive power ±0,5 S + +
Power factor in each phase ±0,5Cos φA, Cos φB, Cos φC
+ -
Total power factor ±0,5 Cos φ + -
Frequency ±0,01 Hz F + -
63Catalogue of Products
www.elpribor.ru
Information displayLType of display Display of measured parameters of current, voltage, frequency, power, power
factors, power flow direction, units of measurements
Seven-segment indicators 7-digit LED (3 lines of 4 digits), digit height: 25 mm (SchM120), 20 mm (SchM96)
Additional features Connection of Display panel MI120, MI80
TelemetryRated voltage 0,5 А; 1 А; 2,5 А; 5 А
Rated current 100 V, 400 V
Frequency 45...55 Hz
Measurement time 0.1 s
Time of setting output analogue signal, max 0.5 s
Basic error limits by current and voltage: ± 0.2%; by power: ± 0.5 %; by frequency: ± 0.01 Hz; by analogue output: ± 0.5%
Galvanic isolation of input and output circuits, power circuits Yes
Short-term overloads by input signal with ratio (maximum) Ratio: 20; number of overloads: 2; duration of each overload, s: 0.5; interval between two overloads, s 0.5.
Input resistance, minby current circuits:by voltage circuits:
0.02 Ω2 MΩ
Communication interfaces/analogue outputRS485 Quantity: 1,2; protocols: Modbus RTU
Data rate: 4800, 9600, 19200, 38400, 57600 baud.Ethernet (100 BASE TX) Quantity: 0,1; protocols: Modbus TCP, IEC 60870-5-104
Analogue output Quantity: 0,1,2,3; reprogrammed ranges: 0...5 mA, 4...20 mA, 0…20 mA, 0...2.5...5 mA, 4...12...20 mA, 0…10…20 mA, -5...0...+5 mA
Remote indicationDigital inputs Quantity: 0, 4, 6, 8, “dry contact” type, voltage 24 V, current 10 mA
Distant controlDigital outputs Quantities: 0, 1, 2, 3 (switch on/off, interlocking) = 300 V, ~200 V, 100 mA
Power supply voltagePower supply – 220 VU – universal power from 85 to 253 VAC, 50 Hz or from 120 to 265
VDC;– 24 VN (24+12/-6) V
Power consumption from power circuit, max. 15 VA
Meter reprogramming (setting)Reprogramming – via program “Configuration Manager” (interface RS485, Ethernet);
– with buttons on the front frame (if any).Reprogramming parameters – indices range (meters with rated currents of 1 A, 5 A and voltage of 100 V)
– password setting;– indication update period: from 0.1 to 10 s;– position of decimal point;– settings for each electrical value (with discrete outputs of up to 3 control signals for commutation equipment);– Interfaces RS485, Ethernet parameters;– output signal parameters;– indication brightness;– parameters of protocol Modbus RTU, Modbus TCP, IEC 60870-5-104 (via program “Configuration Manager»);– Calibration of input and output signals.
Operation ConditionsTemperature range (operating) from -40°С to +70°С
Protection extent IP50
Installation Panel
Wires section 2.5 mm2
Maximum input signal overload (duration) 150% (2 h)Calibration interval 10 years
Guarantee period 60 months
Mean life, min 30 years
Mean time between failures 250,000 h.
64 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
Order form
SchMa – b – с – d – e – f – g – h – i – j
SchMa meter type
Full reference designation code parameter
Rated value or factor of transformation
Power supply voltage
Availability of additional interface and digital inputs
Availability of interface Ethernet
Reference designation of measurement design
Indication colour
Availability of output signals
Custom design
b c d e f g h i j
SchM96 U; U/100 I;I/1; I/5 +х; RSX
x; RE + R, Y, G+
+RS04; X08 х
SchM120 U; U/100 I;I/1; I/5 +х; RSX
x; RE + R, Y, G+
+RS04; RS06; X08 х
NotesSign “+” means that availability of all possible versions of a parameter in the order formula. Sign “x” means that no parameter is available.
SchMa – meter type depending on its overal dimensions:SchM96; SchM120;
b – rated voltage:– line voltage – 100 V, 400 V;– voltage transformation factor (rated secondary winding voltage of 100 V);
c – rated current:– phase current – 0.5 А; 1.0 А; 2.5 А; 5.0 А;– current transformation factor (rated secondary winding current of 1 А and 5 А);
d – reference designation of supply voltage:– 220 VU – universal power: supply voltage of 85 to 253 VAC, 50 Hz or 120 to 265 VDC;– 24VN – DC supply voltage of (24+12/-6) V;
e – reference designation for availability of additional interface RS485 and digital inputs:– х – absence of additional interface and digital inputs,– RSX – availability of additional interface with the absence of digital inputs,– RS04 – availability of additional interface and 4 digital inputs,– RS06 – availability of additional interface and 6 digital inputs (for SchM120 only),– Х08 – absence of additional interface with the availability of 8 digital inputs;Note: with the absence of digital inputs (е = х, е = RSX) the meter may have a design with output signals (analogue or digital).
f – reference designation for the availability of interface Ethernet, hours of real time:– х – specified with the absence,– RE – availability of interface Ethernet;
g – reference designation of measurement design:– 3W - for three-wire connection scheme,– 4W - for four-wire connection scheme;
h – indicators colour– R – red indicators,– G – green indicators,– Y – yellow indicators,– TS – (“Touch Screen”) colour liquid-crystalline display (TS for SchM120 only);
i – availability of output signals– х – specified with the parameter absence;,– 01 – availability of one digital output;– 02 – availability of two digital output;– 03 – availability of three digital output;– 10 (a) – availability of one output analogue signal,– 20 (a, b) – availability of two output analogue signals,– 30 (a, b, c) – availability of three output analogue signals where а, b, c – reference designations of measurement ranges of output analogue signals (А = 0…5 mA; В = 4… 20 mA; С = 0…20 mA; АР = 0…2.5…5 mA; ВР = 4…12…20 mA;СР = 0…10…20 mA; ЕР = -5…0…5 mA) (Example: (30 (С, А, В); 30 (В, В, С); 20 (С, В); 20 (А, А); 10 (А));
j – custom design– otherwise, this parameter is not specified– P – active power meter design;– Q – reactive power meter design;– PQ – active and reactive power meter design.
SchM120 – 400V – 5А – 220VU – RSX – х – 4W – Y – 30 (А, В, СР) TU 25-7504.211.1-2010For SchM120 meter with the following characteristics: rated voltage of 400 V, rated current of 5.0 A, supply voltage of 85 to 253 VAC, 50 Hz or 120 to 265 VDC, the availability of additional interface RS485, 4-wire measurement design, yellow indicator colour, availability of 3 analogue outputs (0…5) mA; (4…20) mA; (0…10…20) mA.
65Catalogue of Products
www.elpribor.ru
for the meter design with digital outputs
Notes:1. Availability of additional interface RS485 (terminals 17, 19) depends on a meter design.2. Resistor R = 430 Ω.
Meters connection diagrams for three-phase four-wire mains
for the meter design with analogue outputs
Notes:1. Availability of additional interface RS485 (terminals 17 - 19) depends on a meter design.2. Resistor R.3. РА – milliammeter.
for the meter design with digital inputs and additional interface RS485 for the meter design with digital inputs without additional interface RS485
for the meter design with digital outputs
Notes:1. Availability of additional interface RS485 (terminals 17 - 19) depends on a meter design.2. Resistor R = 430 Ω.
for the meter design with analogue outputs
Notes:1. Availability of additional interface RS485 (terminals 17 - 19) depends on a meter design.2. Resistor R.3. РА – milliammeter.
Meters connection diagrams for three-phase three-wire mains
Upwr
Upwr
UpwrUpwr
Upwr
Upwr
Power supply
Power supply
Power supplyPower supply
Power supply
Power supply Digital outputs
Digital outputs
PI
PI
PI PI
PI
PI
to PC
to PC
to PC to PC
to PC
to PC
Digital inputs Digital inputs
Analogue outputs
Analogue outputs
Additionalinterface
Additionalinterface
Additionalinterface
Additionalinterface
Additionalinterface
SchM96 (SchM120)
SchM96 (SchM120)
SchM96 (SchM120)SchM96 (SchM120)
SchM96 (SchM120)
SchM96 (SchM120)
66 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Meters connection diagrams for three-phase three-wire mains (continued)
Meters connection diagrams for three-phase four-wire mains with outside voltage transformers of secondary winding rated voltage of 100 V and outside current transformers of secondary winding rated current of 1 A or 5 A
Meters connection diagrams for three-phase three-wire mains with outside voltage transformers of secondary winding rated voltage of 100 V and outside current transformers of secondary winding rated current of 1 A or 5 A
Meters connection diagrams for three-phase three-wire mains with outside current transformers of secondary winding rated current of 1 A or 5 A
Meters connection diagrams for three-phase four-wire mains with outside current transformers of secondary winding rated current of 1 A or 5 A
for the meter design with digital inputs and additional interface RS485
NoteAvailability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.
NoteAvailability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.
NoteAvailability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.
NoteAvailability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.
for the meter design with digital inputs without additional interface RS485
Upwr
Upwr
Upwr Upwr
Upwr
Upwr
Power supply
Power supply
Power supply Power supply
Power supply
Power supply
PI
PI
PIPI
PI
PI
to PC
to PC
to PCto PC
to PC
to PC
Digital inputs Digital inputs
Additionalinterface
SchM96 (SchM120)
SchM96 (SchM120)
SchM96 (SchM120) SchM96 (SchM120)
SchM96 (SchM120)
SchM96 (SchM120)
67Catalogue of Products
www.elpribor.ru
Diagrams of four-wire meters connection into the three-phase three-wire mains with two outside current transformers
Diagrams of four-wire meters connection into the three-phase four-wire mains with two outside current transformers and three voltage transformers
Diagrams for connection of meters with a test box for the three-phase four-wire mains
Diagrams of four-wire meters connection into the three-phase three-wire mains with two outside current transformers and two voltage transformers
NoteAvailability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.
Notes1. Availability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.2. Display and transmitted parameters IB, PB, QB, VAB, cos B – calculated values
NoteAvailability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.
Notes1. Availability of additional interface RS485 (terminals 17 – 19), digital inputs (terminals 17 – 25 or 21 – 25), analogue/digital outputs (terminals 20 – 25) depends on a meter design.2. Display and transmitted parameters IB, PB, QB, VAB, cos B – calculated values
Overall dimensions
Type HхН1, mm L, mm L1, mm A (А1хА2), mm B (В1хВ2), mmSchM96 96
103 75.6100 92+0,8
SchM120 120 125 112+0,9
Upwr
UpwrUpwr
Upwr
Power supply
Power supplyPower supply
Power supply
PI
PI PI
PI
to PC
to PC to PC
to PC
SchM96 (SchM120)
SchM96 (SchM120)SchM96 (SchM120)
SchM96 (SchM120)
Cutout (1:2)
68 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Display panel
MI120.1
MI120.2
MI120.3
MI120.5
MI80.3
Display panel MI are intended to display measurement results of dibital meters and transducers. They are used at power stations, substations and distribution points of generating, grid electrical companies and industrial enterprises.
Modules may be connected via interface RS485 (protocol Modbus RTU), Ethernet to telemechanics meters and PC. Modules MI120.5 has additional options: the possibility for connection of outer SD-card (data archiving), availability of real time clock, events recording and they may be equipped with measuring part.
TypeOverall dimensions, mm
Display weight Displayed parameters Climatic operation conditions
MI120.1
120 х 120 х 76
LED
P, Q, I-40 °С... +70 °С, relative humidity of 95% max. at +35 °С
MI120.2 U
MI120.3 All parameters of meters and transducers: SchM20, SchM96, ENIP-2, E849EL, E900EL, E854EL, E856EL, E1854EL, E1856EL, E1858EL, SchK96, SchK120, Sch02P, Sch72P, Sch96P, Sch120P, SchP02P, SchP72P, SchP96P, SchP120P, SchV02.1, SchV72.1, SchV96.1, SchV120.1
MI120.5colour liquid-crystalline display (touch-sensitive)
+1...+55 °С, relative ambient air humidity of 80% max. at +35 °С
MI80.3 80 x 80 х 85 LED-40 °С... +70 °С, relative humidity of 95% max. at +35 °С
Input signals measurement ranges(for MI120.5 only)
DC measurement ranges:mV: 60, 75, 100, 150, 200, 500V: 1, 2, 5, 10, 2-10, 20, 50, 100, 200, 250mA: 2, 5, 10, 20, 4-20, 50, 100, 200, 500А: 1, 2
AC and frequency measurement meters:mV: 100V: 5, 10, 20, 50, 100, 200, 250Hz: 10…9999mA: 2, 5, 10, 20, 50, 100, 200А: 1.2
Interface
RS485 (protocol Modbus RTU)
For MI120.5 only:Ethernet (for MI120.5 with RS485 design)IEC 60870-5-104 (Ethernet channel),IEC 60870-5-101 (EIA RS485 channel)
Additional options (for MI120.5 only)The possibility for connection of outer SD-card (data archiving), availability of real time clock, events recording
Power supply
(5+4/-0.5) VDC (except for MI120.5);(12+6/-3) VDC;(24+12/-6) VDCuniversal power: supply voltage of 85 to 253 VAC, 50 Hz or 120 to 265 VDC;
Power consumption, maxMI80.3 - 2 VA;MI120.1, MI120.2, MI120.3 - 4 VA;MI120.5 - 10 VA
Weight, kg, max. 0.4 kg (MI80.3 - 0.2 kg)
Guarantee period 24 months
Mean life 15 yeas (LCD – 10 years)
Mean time between failures 100,000 h
Example of label MI120.1, MI120.2, MI120.3
Example of label MI120.5
Contact Signal
Upow.
Power supply
Interface RS485 MI120.1
Input signal Upow.
100 V
Cont. Signal
MI120.5
69Catalogue of Products
www.elpribor.ru
Order formOverall and mounting dimensions
MI a b – с – d – e – f – g – h
MIa – module type:MI80 – 80×80 (for multi-purpose LED only);MI120 – 120×120.
b – design according to type of displayed parameters and indicator panels:1 – load indication module (P, Q, I), LED – displays active and reactive power, average load current;2 – voltage indication module (U), LED – displays phase or line voltages;3 – multi-purpose indication module, LED – displays all basic measured and calculated parameters;5 – multi-purpose indication module, colour touch-screen LCD– displays all basic measured and calculated parameters.
c – reference designation of supply voltage:5 VN – (5+4/-0.5) VDC (except for MI120.5);12 VN – (12+6/-3) VDC;24 VN – (24+12/-6) VDC;220 VU – universal power: supply voltage of 85 to 253 VAC,50 Hz or 120 to 265 VDC;
d – availability of digital interface RS485;х – with the parameter absence (for MI120.5 only, with RE design);RS – availability of digital interface RS485;
e – availability of digital interface Ethernet (this parameter is used for MI120.5 only)х – with the parameter absence (for MI120.5 only, with RS design);RE – availability of digital interface Ethernet;
f – the possibility for connection of outer SD-card, the availability of real time clock (this parameter is used for MI120.5 only with the possibility of events recording)х – with the parameter absence;SD – the possibility for connection of outer USB-flash disk;
g – indicator colour or type:G – green; R – red; Y – yellow;TS – (“Touch Screen”) colour liquid-crystalline display (this parameter is used for MI120.5 only);
h – custom design:х – with the parameter absence– input signals measurement ranges (for MI120.5 only):10…9999 Hz – input signal frequency range; (0…Х) – input DC signal;Х – input AC signal.
MI120.1, MI120.2, MI120.3
MI120.5
70 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
MI120.1 – 220 VU – RS – x – x – G – х TU 25-7504.213-2011.For the module with the following characteristics: 120×120 front frame size, basic load indication module, LED, supply voltage of 85 to 253 VAC, (50 ± 0.5) Hz or 120 to 265 VDC, the availability of digital interface RS485, indication colour – green.
MI120.1 – 24VN – RS – x – x – TS – х TU 25-7504.213-2011.For the module with the following characteristics: 120×120 front frame size, multi-purpose load indication module, LCD, supply voltage of 24 VN DC, the availability of digital interface RS485.
MI120.5 – 12VN – x – RE – SD – TS – 10…9999Hz TU 25-7504.213-2011.For the module with the following characteristics: 120×120 front frame size, multi-purpose load indication module, colour touch sensitive LCD, supply voltage of 12 VN DC, the availability of digital interface Ethernet, the possibility of SD-card connection, the availability of real-time clock, input signal frequency.
MI120.5 – 12VN – RS – RE – SD – TS– х TU 25-7504.213-2011.For the module with the following characteristics: 120×120 front frame size, multi-purpose load indication module, colour, touch sensitive LCD, supply voltage of 12 VN DC, the availability of digital interfaces RS485, Ethernet, the possibility of SD-card connection, the availability of real-time clock.
MI80.3
Cutout (1:2)
2 bo
lts
71Catalogue of Products
www.elpribor.ru
AC, VOLTAGE AND FREQUENCY METERS
SchP02P, SchP72P,SchP96P, SchP120P
Meters are intended to measure and convert the effective value of current, voltage and frequency in one-phase and three-phase AC circuits into output unified DC signals and to transmit measured values through serial digital interface RS485, which allow using meters in automated systems of various purpose.
The meters have the possibility of programming with built-in buttons or through interface RS485:
– Indication range, position of decimal point;
– level of controlled input signals (settings);
– change in brightness of digital indicators illumination;
– interface parameters.
SchP120P meets the requirements of PJSC ROSSETI and PJSC FGC UES, they are recommended for the use at facilities of JSC ROSSETI and PJSC FGC UES.
Type Overall dimensions, mm Panel cutout, mm
Sign height, mm
Weight, kg, max.
SchP02P 96 х 48 х 148 92х45 20 0.4
SchP72P 72 х 72 х 103 68х68 14 0.2
SchP96P 96 х 96 х 103 92х92 20 0.5
SchP120P 120 х 120 х 103 112х112 20 0.5
Accuracy class when measuring:when conversion:
0.2 or 0.50.5
Temperature range (operating) UKhL3.1 (-40 °С... +70 °С)
Maximum indication range 0...9999
Frequency range measured/converted signals 45 ... 65 Hz (300...500 Hz)
Number of measuring channels 1
Number of displayed parameters1 or 2 (SchP72P, SchP96P, SchP120P) for displaying input signal frequency
Galvanic isolation of input and output circuits, power circuits
Yes
Front frame protection level IP50
Interface RS485 (protocol Modbus RTU)
– Basic for data transmission (for SchP120P, manufacture without RS485 is possible);– Additional for data transmission or connection of the Display panel (MI120, MI80) and the display
Interface exchange rate4600, 9600, 19200, 38400, 115200 bit/s.(115200 bit/s is set through SW “Configuration Manager”)
Analogue output (accuracy class 0.5)Quantity: 0; 1; 2;Ranges: 0...5 mA, 4...20 mA, 0…20 mA, 0...2.5...5 mA, 4...12...20 mA, 0…10…20 mA
Load resistance2.5 kΩ for ranges of 0...5 mA, 0...2.5...5 mA0.5 kΩ for ranges of 0...20 mA, 4...20 mA,4...12...20 mA, 0…10…20 mA
Digital outputQuantity: 0; 1; 2;DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Maximum permissible input signal overload (from the upper limit of the measurement range)
150% (1 minute)
Time of setting output analogue signal, max 1.0 s
Input resistance at voltage measurement, min. (1-0.005) MΩ
Voltage drop when measuring current 500 mA, 1000 mA, 2000 mA, 1 A, 2 A, 5 A, max.
30 mV
Power supply
– 5 VN (5+4/-0.5) VDC,– 12 VN (12+6/-3) VDC,– 24 VN (24+12/-6) VDC,– 220 VU (85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC),– 220 V (85...253 VAC, (50 ± 0.5) Hz)
Power consumption, max.
2.5 V•A for SchP02P, SchP72P at supply voltage5 VN, 12 VN, 24 VN3.0 V•A for SchP96P, SchP120P at supply voltage5 VN, 12 VN, 24 VN6.0 V•A at supply voltage 220 VU, 230 V
Calibration interval 6 years
Guarantee period 36 months
Mean life 30 years
Mean time between failures 150000
Note: it is possible to connect the outer circuits according to the designation of connector contacts to the terminals “for screw” using a cord of up to 4 mm2 in cross-section, multi-core wires of up to 2.5 mm2. When connecting supply DC voltage of 120...265 V at supply voltage of 220 VU to power contacts “L”, “N”, any polarity is possible.
72 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Order form
SchP120P – 500V, 45...65Hz – 220VU – 2RS – 22 (А,С) – К – 0.5 – ОМ2 TU 25-7504.219-2012For SchP120P meter, main indicator – input signal measurement range 0...500 V, the additional indicator – frequency measurement range 45...65 Hz, supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC, two interfaces RS485, two analogue outputs 0…5 mA and 0…20 mA, two digital output, red indicators, accuracy class 0.5, custom design ОМ2.
Overall and mounting dimensions
SchPa – b1, b2 – с – d – e – f – g – h
а – meter type (by dimensions, mm):SchP02P – 96×48,SchP 72P – 72.72,SchP 96P – 96.96,SchP 120P – 120.120;
b1 – measurement range for the input signal of the main indicator with direct connection, transformation factor with connection through the outside current or voltage transformer.mV: 100; 150; 200; 250; 500; 1000; 2000V: 1; 2; 5; 10; 20; 50; 100; 150; 200; 250; 380; 500; 750mA: 2; 5; 10; 20; 50; 100; 200; 500; 1000; 2000А: 1; 2; 5
By default, frequency range input signal is 45...65 Hz (when ordering, it is not specified).When ordering the meter with input signal frequency range 300…500 Hz only with the main indicator, specify reference designation 400 Hz in parameter b1 in brackets.
Note – If the indication range differs from the measurement range the input signal and from the transformation factor, give additionally the ordered indication range in the note to the order formula.
b2 – measurement range the input signal frequency of the additional indicator, except for meter ShP02P:45...65 Hz – for range 45…65 Hz,400 Hz – for range 300…500 Hz,– with the absence, this parameter is not specified;
c – reference designation of supply voltage:5 VN, 12 VN, 24 VN, 220 VU, 230 V;
d – availability of interfaces RS485:1RS – one interface,2RS – two interfaces;х – with the absence of parameter (for SchP120P only);
e – reference designation of analogue and digital outputs:02 – two digital outputs without analogue output,11 – one analogue and one digital output,12 – one analogue and two digital outputs,20 – two analogue outputs without digital ones,22 – two analogue and two digital outputs,х – without analogue and digital outputs;
Note – the reference designation of analogue output is specified after figures in brackets: А – 0...5 mA, B – 4...20 mA, С – 0...20 mA, АР – 0…2.5…5 mA, ВР – 4…12…20 mA, СР – 0…10…20 mA, when ordering two analogue outputs, specify it separated by a comma.
f – indicators colour:R – red,G – green,Y – yellow;
g – accuracy class: 0.2 or 0.5;
h – custom design:ОМ2 - meters for marine application,А – for operation at NPP (safety class 4), do not specify in other cases.
SchPa meter type
Full reference designation code parameter
b1, b2 с d e f g h*
SchP02P b1 + 1RS х, 12, 20, 22 + + +
SchP72P b1, b2 + 1RS х, 02, 11, 20 + + +
SchP96P b1, b2 + 1RS,2RS х, 12, 20, 22 + + +
SchP120Pb1, b2
+1RS,2RS х, 12, 20, 22
+ ++
b1 х х х
* For the meters with special design, accuracy class 0.5.
NotesSign “+” means that availability of all possible versions of a parameter in the order formula. Sign “x” means that no parameter is available.Unused parameter h is not specified.
Type HхН1, mm
L1, mm, max
L, mm, max
A (A1xA2), mm
B (B1xB2), mm
SchP120P 120х120 75.6 103 125х125 112+0.9
SchP96P 96х96 75.6 103 100х100 92+0.8
SchP72P 72х72 75.6 103 75х75 68+0.7
SchP02P 96х48 121.5 148 100х5092+0.8 х45+0.6
Ordering example
Cutout (1:2)
73Catalogue of Products
www.elpribor.ru
Diagrams for connection of meters SchP02P
Diagrams for connection of meters SchP72P
Diagrams for connection of meters SchP96P
Diagrams for connection of meters SchP120P
for the design with parameter с = 5 VN, 12 VN, 24 VN
for the design with parameter с = 5 VN, 12 VN, 24 VN
for the design with parameter с = 5 VN, 12 VN, 24 VN
for the design with parameter с = 5 VN, 12 VN, 24 VN for designs with parameter с = 220 VU, 230 V
Upwr – supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC (220 VU), supply voltage of 85...253 VAC, 50 Hz (230 V).
for designs with parameter с = 220 VU, 230 V
for designs with parameter с = 220 VU, 230 V
for designs with parameter с = 220 VU, 230 V
Input
Input
Input
InputInput
Input
Input
Input
Upwr
Upwr
Upwr
Upwr
Power supply
Power supply
Power supplyPower supply
Power supply
Power supply
Power supply
Power supply
PI
PI
PI PI
PI PIPI PI
PI PI
PI
PI
to PC to PC
to PC to PC
to PC
to PCto PC
to PCto PC
to PC
to PC to PC
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource Supply
voltagesource
Supplyvoltagesource
Supplyvoltagesource
Supplyvoltagesource
To measuring and control meters To measuring and control meters
To measuring and control metersTo measuring and control meters
To measuring and control meters To measuring and control meters
To measuring andcontrol meters
To measuring andcontrol meters
SchP02PSchP02P
SchP72P SchP72P
SchP96P
SchP96P
SchP120P SchP120P
74 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
SMALL DIGITAL AC METERS
Type Overall dimensions, mm Sign height, mm Weight, kg, maximum
SchP00P 48 × 24 × 90 9.9 0.2
SchP01P 96 × 24 × 90 9.9 0.2
SchP02.01P 96 × 48 × 90 20 0.3
SchP00P, SchP01P,SchP02.01P
Small digital meters SchP00P, SchP01P, SchP02.01P are intended to measure and convert the effective value of current, voltage and frequency in one-phase electrical circuits and other AC circuits into output unified DC signals and to transmit measured values through serial digital interface RS485.
The meters are single-channel and single-scale meters with designs by overall dimensions, measurement ranges, indication ranges, supply voltage, availability of interface, digital and analogue outputs, indicators colour, accuracy class, custom design.
One-phase meters can be used in three-phase electrical circuits for measurement and conversion of parameters of one phase.
The meters could be used complete with primary transducers for measurement non-electrical values if ranges of output electrical signal of primary transducers corresponds to the meters input signal ranges.
The meters are used in the energy industry and other sectors of industry for control of electrical parameters.
Accuracy class – when measuring AC intensity and voltage – 0.2 or 0.5;– when measuring input signal frequency – 0.05;– when converting – 0.5.
Temperature range (operating) -40 °С…+50 °С
Maximum indication range 0... plus 9999
Frequency range measured/converted signals 45 ... 65 Hz (by default),300 ... 500 Hz (optionally, when ordering)
Number of measuring channels 1
Number of displayed parameters 1 or 2 (the 2nd one for display of input signal frequency, sequential display)
Galvanic isolation of input and output circuits, power circuits
The meters have galvanic isolation in the power circuit, output circuits (SchP00P meters have no galvanic isolation in interface RS circuit)
Protection extent on the front frame IP50
Interface RS485 (protocol Modbus RTU) Quantity: 0 or 1
Interface exchange rate 9600, 19200, 38400, 57600 bit/s.
Analogue output (accuracy class 0.5) Quantity: 0, 1, 2Ranges: 0...5 mA, 4…20 mA, 0...20 mA,0…2.5…5 mA, 4…12…20 mA, 0…10…20 mA
Load resistance, kΩ 0.5 (for 4...20 mA, 0...20 mA, 4…12…20 mA, 0…10…20 mA)2.5 (for 0...5 mA, 0…2.5…5 mA)
Digital output Quantity: 0; 1; 2;DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Maximum permissible input signal overload 150%
Time of setting output analogue signal, max 0.5 s
Input resistance at voltage measurement, min. (1±0.005) MΩ
Power supply – 5 V (5±0.25) VDC,– 12 V (12±0.6) VDC,– 24 V (24±1.2) VDC,– 5 VN (5+4/-0.5) VDC,– 12 VN (12+6/-3) VDC,– 24 VN (24+12/-6) VDC– outer unit of balanced power supply of 5 V (for SchP00P)
Power consumption, max SchP00P – 1.7 VA; SchP01P – 2.7 VA; SchP02.01P – 3.2 VA
Calibration interval 10 years
Guarantee period 36 months
Mean life, min 20 years
Mean time between failures 200 000 h
75Catalogue of Products
www.elpribor.ru
Ordering examples
Order form
SchP00P – 10kV/100V – × – × – × – R – 0.5, TU 25-7504.228-2015For SchP00P meter, transformation factor of 10 kV/100 V with outer unit of balanced power supply of 5 V without interface, analogue and digital outputs; red indicators, accuracy class 0.5.
SchP01P – 100mA – 24V – 1RS – × – R – 0.5 – А, TU 25-7504.228-2015For SchP01P meter, input signal measurement range 0...100 mA, supply voltage of 24 VDC (balanced), one interface RS485, without analogue and digital outputs, red indicators, accuracy class 0.5, custom design A, indication range 0...50 m.
SchPa – b – с – d – e – f – g – h
SchPа – meter type (by the Overall dimension, mm):SchP00P – 48×24, SchP01P – 96×24, SchP02.01P – 96×48,
b – reference designation of input signal measurement range:mV: 100; 150; 200; 250; 500; 1000; 2000V: 1; 2; 5; 10; 20; 50; 100; 150; 200; 250;380 (except for SchP00P); 500 (except for SchP00P);750 (except for SchP00P, SchP01P)mA: 2; 5; 10; 20; 50; 100; 200; 500; 1000; 2000А: 1; 2; 5By default, frequency range input signal is 45...65 Hz (when ordering, it is not specified).When ordering the meter with input signal frequency range 300…500 Hz, specify reference designation 400 Hz in parameter b in brackets.Note: if the indication range differs from the measurement range the input signal and from the transformation factor, give additionally the ordered indication range in the note to the order formula.
c – reference designation of supply voltage:5V, 12V, 24V, 5VN, 12VN, 24VN;× – with outer unit of balanced power supply of 5 V (for SchP00P);
d – availability of interface RS485:1RS – one interface,× – no interface;
e – reference designation of analogue and digital outputs:01 – one digital outputs without analogue outputs,10 – one analogue output without digital input,11 – one analogue and one digital output,12 – one analogue and two digital outputs,20 – two analogue outputs without digital ones,22 – two analogue and two digital outputs,× – no analogue and digital outputsNote – reference designation of analogue output is specified after figures in brackets: А – 0...5 mA, В – 4...20 mA, С – 0...20 mA,АР – 0…2.5…5 mA, ВР – 4…12…20 mA, СР – 0…10…20 mA, when ordering two analogue outputs, specify it separated by a comma;
f – indicators colour:R – red, G – green, Y – yellow;
g – accuracy class:0.2 or 0.5;
h – custom design:А – for operation at NPP (safety class 4),– with the absence of custom design parameter is not specified.
Connection diagrams
SchPa meter type
Full reference designation code parameter
b1 с d е f g h
SchP00P b1 х, 5V, 12V, 24V х, 1RS X + + +
SchP01P b1 5V, 12V, 24V х, 1RS х,01,10,11 + + +
SchP02.01P b15VN, 12VN, 24VN
1RS х, 12,20,22 + + +
NotesSign “+” means that availability of all possible versions of a parameter in the order formula. Sign “x” means that no parameter is available in the order formula.Unused parameter h is not specified.For SchP00P meter, interface RS485 without galvanic isolation.
SchP00P SchP02.01
SchP01P
Input
Input
Input
Power supply
Power supply
Power supply
PIPI
PI
to PCto PC
to PC
Inputsignal source
Inputsignal source
Inputsignal source Supply
voltage source Supply
voltage source
Supply voltage source
To m e a s u r i n g a n d c o n t r o l m e t e r s
To measuringand control
meters
SchP00P SchP02.01P
SchP01P
76 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
SchP00P
SchP01P
SchP02.01P
Cutout (1:2)
Cutout
Cutout
bracket
bracket
bracket
bracket Screw М3x16
Screw М3x16
77Catalogue of Products
www.elpribor.ru
AC, VOLTAGE AND FREQUENCY METERS
SchK96, SchK120
The meters are intended to measure and convert current, voltage and frequency in one-phase and three-phase electrical circuits and other AC circuits into output unified DC signals and to transmit measured values through serial digital interface RS485.
Type Overall dimensions, mm Panel cutout, mm
Sign height, mm
Weight, kg, max.
SchK9696 х 96 х 103 (w/ rear cover)96 х 96 х 75,6 (w/o rear cover)
92х92 14 0.4
SchK120120 х 120 х 103 (w/ rear cover)120 х 120 х 75,6 (w/o rear cover)
112х112 20 0.5
Accuracy class 0.5 or 1.0
Temperature range (operating) -40 °С... +55 °С (UKhL3.1)
Maximum indication range 0...9999
Standard frequency range measured signals 45...65 Hz
Number of measuring channels 1, 2 or 3
Protection extent on the front frame IP40
Interface RS485 (protocol Modbus RTU)
Interface exchange rate 9600, 19200, 38400, 57600 baud.
Analogue output per each displayed parameter (accuracy class 0.5)
0...5 mA, 0…20 mA, 4...20 mA
Digital outputDC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Maximum permissible input signal overload 150% (2 hours)
Time of setting output analogue signal, max 1.0 s
Power supply
– 12 VN (12+6/-3) VDC,– 24 VN (24+12/-6) VDC,– 220 VU from 85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC,– 230 V from 85...253 VAC, (50 ± 0.5) Hz
Power consumption, max 12.5 V•А
Input resistance at voltage measurement, min.
– 50 kΩ For the meters with measurement limit of 50 V;– 100 kΩ For the meters with measurement limit of 100 V;– 250 kΩ For the meters with measurement limit of 250 V;– 450 kΩ For the meters with measurement limit of 500 V.
Voltage drop at the input when measuring current (max.):for measurement range 500 mA, 1000 mA, 2000 mA, 1 А, 2 А, 5 А
30 mV
Calibration interval 36 months
Guarantee period 24 months
Mean life, min 15 years
Mean time between failures, min 100,000 h
Note: it is possible to connect the outer circuits according to the designation of connector contacts to the terminals “for screw” using a cord of up to 4 mm2 in cross-section, multi-core wires of up to 2.5 mm2. When connecting supply DC voltage of 120...265 V to power contacts “L”, “N”, any polarity is possible.
78 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering exampleOrder form
SchK120-500V, 200V, 200V-4.0-24VN-RS-21-А-R-0.5 TU 25-7504.206-2009For SchK120 meter with the measurement range the first channel – 0...500 V, the second and third channels – 0...200 V with direct connection, supply voltage of 24 VN DC, interface RS485, digital outputs, analogue outputs of 0...5 mA, red indicators, accuracy class 0.5.
Overall and mounting dimensions
SchK а – b1, b2, b3 – c – d – e – f – g – h – i
а – meter type (by dimensions):SchK96 – 96х96SchK120 – 120х120
b1, b2, b3 – measurement range*:V: 50; 100; 250; 500mA: 500А: 1; 2; 5V**: 380; 660kV**: 3; 6; 10; 11; 15; 20; 35; 100; 110; 150; 220; 330; 400; 500; 750А***: 1; 5; 10; 15; 20; 30; 40; 50; 75; 80; 100;150; 200; 300; 400; 500; 600; 750; 800kA***: 1; 1,2; 1,5; 2;3; 4; 5; 6; 8; 10; 12; 14; 16; 18; 20;25; 28; 30; 32; 35; 40Hz****: 45…65* – measurement range is specified for each channel** – connection through outside voltage transformer with secondary winding rated voltage of 100 V.*** – connection through outside current transformers with secondary winding rated current of 1 A or 5 A**** – first channel voltage frequency
с – digit:4,0
d – power:12 VN (12+6/-3) VDC24 VN (24+12/-6) VDC220 VU from 85...253 VAC, (50 ± 0.5) Hz or 120...265 VDC230 V from 85...253 VAC, (50 ± 0.5) Hz
e – interface:RS – RS485 (obligatory specified)
f – digital outputs:21 – digital output per each channel00 – no digital outputs
g – analogue outputs:А – 0…5 mA per each channelB – 4…20 mA per each channelC – 0…20 mA per each channel– with the absence, this parameter is not specified
h – indicators colour:R – red, G – green, Y – yellow
i – accuracy class:0,51,0
Type HхН1, mm L1, mm, max. (w/o cover)
L, mm, max. (w/ cover) A (A1xA2), mm B (B1xB2), mm
SchK96 96х9675.6 103
100 92+0.8
SchK120 120х120 125 112+0.9
Cutout (1:2)
79Catalogue of Products
www.elpribor.ru
Connection diagrams
for the design with parameter d = 12 VN, 24 VN for designs with parameter d = 220 VU, 230 V
Upwr – supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC (220 VU), supply voltage of 85...253 VAC, 50 Hz (230 V).
Upwr
Power supply Power supply
PIPI
to PC to PC
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Supplyvoltagesource
To m e a s u r i n g a n dc o n t ro l m e t e r s
To m e a s u r i n g a n dc o n t ro l m e t e r s
To m e a s u r i n g a n dc o n t ro l m e t e r s
To m e a s u r i n g a n dc o n t ro l m e t e r s
Channel 1 Channel 2 Channel 3
SchK96 (SchK120)
Channel 1 Channel 2 Channel 3
SchK96 (SchK120)
80 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
One-phase mains power meters
SchV02.1, SchV72.1,SchV96.1, SchV120.1
SchV02.1, SchV72.1, SchV96.1, SchV120.1 meters are intended to measure and convert active, reactive and total power of one-phase AC circuits into output unified DC signals and serial digital interface RS485, which allow using the meters in automated systems of various purposes.
The meters provide the possibility for programming with built-in buttons or through the interface: indication range, decimal point position; level of the controlled values of input signals (settings); change in brightness of digital indicators illumination; interface parameters.
Type Overall dimensions, mm Panel cutout, mm
Sign height, mm
Weight, kg, max.
SchV02.196 х 48 х148 (w/ protective cover)96 х 48 х 121,5 (w/o cover)
92х45 20 0.4
SchV72.172 х 72 х 103 (w/ protective cover)72 х72 х 75,6 (w/o cover)
68х68 14 0.4
SchV96.196 х 96 х 103 (w/ protective cover)96 х 96 х 75,6 (w/o cover)
92х92 20 0.4
SchV120.1120 х 120 х 103 (w/ protective cover) 120 х 120 х 75,6 (w/o cover)
112х112 20 0.5
Accuracy class 0.5
Temperature range (operating) UKhL3.1 (-40... +50 °С)
Maximum indication range -9999...+9999
Rated frequency range measured signals 50 Hz
Number of measuring channels 1 current input; 1 voltage input
Front frame protection level IP50
Rated power factor For wattmeter cosφ=1, for wattmeter sinφ=1
Interface RS485 (protocol Modbus RTU)
Interface RS485 (protocol Modbus RTU)– basic for data transmission;– additional for data transmission or connection of the display and Display panel (MI120, MI80)(for SchV96.1, SchV12.1 only)
Interface exchange rate 4800, 9600, 19200, 38400 baud.
Analogue output (accuracy class 0.5)Quantity: 0, 1, 2Range: 0...5 mA, 0...2.5...5 mA, 0…20 mA, 4...12...20 mA, 4...20 mA, 0…10…20 mA
Digital outputQuantity: 0, 1, 2DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Maximum permissible input signal overload 150% (2 hours)
Measurement time, max. 0.1 s
Time of setting output analogue signal, max 0.5 s
Voltage drop when measuring current 30 mV
Power supply
– 5 VN (5+4/-0.5) VDC,– 12 VN (12+6/-3) VDC,– 24 VN (24+12/-6) VDC,– 220 VU (85...253 VAC,– (50 ± 0.5) Hz or 120 ... 265 VDC)
Power consumption, max 6 V•А
Guarantee period 2 years
Mean life 25 years
Mean time between failures 200,000
Note: outer connections are carried out with screw terminals ensuring connection of copper or aluminium wires of up to 2.5 mm2 in cross-section (diameter of 1.8 mm max.).
81Catalogue of Products
www.elpribor.ru
Ordering example
Order form
SchV02.1 – 100V – 5А – MW – х – 220VU – 1RS – CP – 12 – З TU 25-7504.217-2015For the meter with the following characteristics: type of SchV02.1 meter, rated voltage of 100 V, rated current of 5 A, power measurement unit is MW, no additional indication parameter, supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC, one interface RS485, range change in output analogue signal of 0…10…20 mA, two digital outputs, green indication colour.
Overall and mounting dimensions
SchVa – b – c – d – e – f – g – h – i
а – meter type (by dimensions):02.1 – 96×48; 72.1– 72×72; 96.1– 96×96; 120.1 – 120×120
b – rated voltage, or Kvt:100 V, 380 V, 400 V – rated voltage;U/100 – U rated voltage of the voltage transformer primary winding, secondary winding rated voltage of 100 V
c – rated current, or Kct:0.5А, 1А, 2.5А, 5А – rated current;I/1, I/5 – I rated current of the current transformer primary winding, secondary winding rated current of 1А or 5А
d – unit of measurement:W, kW, MW, ±VAr, ±kVAr, ±MVAr, W/±VAr, kW/±kVAr, MW/±MVAr
e – power:220 VU – universal power: supply voltage of 85 ...253 VAC, 50 Hz or 120...265 VDC;5 VN – (5+4/-0.5) VDC;12 VN – (12+6/-3) VDC;24 VN – (24+12/-6) VDC
f – interface:1 RS – one RS485 (main)2 RS – two RS485 (main and additional) Note: meters SchV02.1, SchV72.1 are manufactured with one interface only (f = 1RS).
g – reference designations of measurement range output analogue signalх – no parameter;Х – one output analogue signal(Example: А, В, С, ВР)Х/Y – two output analogue signals(Example: А/А; А/В; С/ВР) (А = 0…5 mA; В = 4…20 mA; С = 0…20 mA; АР = 0…2.5…5 mA; ВР = 4…12…20 mA; СР = 0…10…20 mA);
h – availability of analogue and digital outputs (designation depends on a number of output signals):х – no parameter (with the absence of output analogue and digital signals);20, 02, 11 – SchV72.112, 20, 22 – SchV96.1, 02.1, SchV120.1, where11 – 1 analogue output, 1 digital output;12 – 1 analogue output, 2 digital outputs;02 – with no analogue output, 2 digital outputs;20 – 2 analogue outputs with no digital output (the parameter is specified for a meter with the unit of displayed value х W/х VAr);22 – 2 analogue outputs, 2 digital outputs (the parameter is specified for SchV120.1, SchV96.1, SchV02.1 design only with the unit of displayed value х W/х VAr);
I – Indication colour:R – red; Y – yellow; G – green.
SchVa meter type
Full reference designation code parameter
Rated value or factor of transformation
Displayed parameter
Supply voltage
Number of interfaces
Number of analogue and digital outputs
Indication colour
b с d e f g h
SchV02.1 U IW, VAr, ±VAr
+ 1RS ×, 12, 20, 22 +
SchV72.1 U I
W, VAr, ±VAr
+ 1RS×, 02, 11, 20
+W/VAR, W/±VAr
×, 02, 20
SchV96.1 U I
W, VAr, ±VAr
+ 1RS, 2RS×, 12, 20, 22
+W/VAR, W/±VAr
×, 20, 22
SchV120.1 U I
W, VAr, ±VAr
+ 1RS, 2RS
×, 12, 20, 22
+W/VAR, W/±VAr
×, 20, 22
NotesSign “+” means that availability of all possible versions of a parameter in the order formula.Sign “–” means that no parameter is available in the order formula.Analogue output ranges are specified in brackets after a number of outputs.
Type HхН1, mm L, mm, max (w/ cover)
L1, mm, max (w/o cover)
SchV02.1 96х48 148 121.5
SchV72.1 72х72
103 75.6SchV96.1 96х96
SchV120.1 120х120
82 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
SchV02.1
Connection diagrams
SchV72.1
SchV96.1 SchV120.1
Power supply
Power supply
Power supply Power supply
Power supply
Power supply
Power supply
Power supply
Power supply
PI
PIPIPI PI
PIPI
to PC to PCto PC to PC
to PC to PC
to PC
~I in ~U in
~I in ~U in ~I in ~U in
~ Iin ~ Uin~ Iin ~ UinSchV96.1 SchV120.1
SchV 72.1SchV 72.1
SchV 02.1
Power supply
83Catalogue of Products
www.elpribor.ru
FREQUENCY METERS
Type Overall dimensions, mm, max Sign height, mm, min
Weight, kg, maximum
SchCh02 96 × 48 × 148 (w/ protective cover)96 × 48 × 122 (w/o cover)
20 0.4
SchCh72 72 × 72 × 103 (w/ protective cover)72 × 72 × 76 (w/o cover)
14 0.2
SchCh96 96 × 96 × 103 (w/ protective cover)96 × 96 × 76 (w/o cover)
20 0.5
SchCh120 120 × 120 × 103 (w/ protective cover)120 × 120 × 76 (w/o cover)
20 0.5
SchCh02, SchCh72,SchCh96, SchCh120The meters are intended to measure
and convert AC frequency in one-phase electrical circuits and other AC circuits into output unified DC signals and to transmit measured values through serial digital interface RS485.
The possibility for data exchange through interface RS485, availability of output analogue DC signals and digital outputs allow using the meters in automated systems of various purposes.
The meters have the possibility for programming decimal point position, level of the controlled values of input signals (settings), operative change in brightness of digital indicators illumination.
Accuracy classfrequency measurement:
frequency conversion:with digit of 4.0 – 0.05; with digit of 5.0 – 0.01.
Temperature range (operating) -40°C ... +70 °C (UKhL 3.1)
Frequency measurement range 4.0 (measurement range – 10…9999 Hz);5.0 (measurement range – 10…15000 Hz);
Input voltage range 150 V, 500 V
Digit 4.0; 5.0
Galvanic isolation in the power circuit and interface circuit
Yes
Protection extent on the front frame IP50
Interface RS485 (protocol ASCII, Modbus RTU)
Data exchange rate through interface RS485 9600, 19200, 38400, 57600 baud.
Analogue output Quantity: 0, 1, 2;Ranges: 0...5 mA, 4...20 mA, 0…20 mA, 0...2.5...5 mA, 4...12...20 mA, 0…10…20 mA
Digital output Quantity: 0, 1, 2;DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Power supply voltage – 12 VN (12+6/-3) VDC,– 24 VN (24+12/-6) VDC,– 220 VU of 85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC,– 230 V from 85...253 VAC, (50 ± 0.5) Hz
Meter power consumption from the mains, max. 3.5 V•А For the meters with supply voltage of 12 VN,24 VN;5.0 V•А For the meters with supply voltage of 220 VU,230 V.
Guarantee period 36 months
Mean life, min 20 years
Mean time between failures 200,000 h
Outer measuring and power circuits are connected in accordance with the terminals designation.Wires are connected “for screw”.Cross-sections of wires connected directly to terminals is 2.0 mm2 max.
Note:The meters are produced with QCD acceptance only.
84 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering example
Order form
SchCh120 – 150V – 220VU – 2RS – 22(В,В) – R – 5.0, TU 25-7504.224-2014SchСh120 meter, input voltage 150 V, supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC, two interfaces, two analogue outputs 4…20 mA, two digital output, red indicators, digit 5.0.
Overall and mounting dimensions
SchCha – b – с – d – e – f– g
a – meter type:02 – 96х48 mm;72 - 72х72 mm;96 – 96х96 mm;120 – 120х120 mm.
b – reference designation of input voltage range:150 V, 500 V.
c – reference designation of supply voltage:12 VN, 24 VN, 220 VU, 230 V.
d – availability of interfaces RS485:1RS – main,2RS – main and additional(only for dimensions of 96, 120);х – with the parameter absence (for SchCh120 only).
e – reference designation of a number of analogue and digital outputs, analogue outputs change ranges:a number of analogue and digital outputs (the first figure – a number of analogue outputs, the second figure – a number of digital outputs);02, 11, 12, 20, 22 (depending on dimensions)х – without analogue and digital outputs,analogue outputs change ranges (specified in brackets; when ordering two analogue outputs, specify it separated by a comma):А, В, С, АP, ВP, СP, whereА: 0...5 mA, В: 4...20 mA, C: 0...20 mA,АР: 0…2.5…5 mA, ВР: 4…12…20 mA, СР: 0…10…20 mA,Examples: 12(В); 22(А,С), 20(AP,CP);
f – indicators colour:R – red, G – green, Y – yellow;
g – digit:4.0 (measurement range – 10…9999 Hz; accuracy class – 0.05); 5.0 (measurement range – 10…15000 Hz; accuracy class – 0.01).
SchCha meter type
Full reference designation code parameter
Input voltage range
Supply voltage
Number of interfaces
Number of analogue and digital outputs
Indication colour Digit
b c d e f g
SchCh02 + + 1RS х, 12, 20, 22 + +
SchCh72 + + 1RS х, 02, 11, 20 + +
SchCh96 + + 1RS, 2RS х, 12, 20, 22 + +
SchCh120 + +1RS, 2RS х, 12, 20, 22
++
х х 4,0NotesSign “+” means that availability of all possible versions of a parameter in the order formula. Sign “x” means that no parameter is available in the order formula.Analogue output ranges are specified in brackets after a number of outputs.
Type HхН1, mm L1, mm, max. (w/o cover)
L, mm, max. (w/ cover) A (A1xA2), mm B (B1xB2), mm
SchCh02 96х48 148 122 100х50 92+0.8 х45+0.6
SchCh72 72х72
103
76 75 68+0.7
SchCh96 96х96 76 100 92+0.8
SchSchCh120 120х120 76 125 112+0.9
Cutout (1:2)
85Catalogue of Products
www.elpribor.ru
Connection diagrams
SchCh02
SchCh72
SchCh96
SchCh120
for the design with parameter c = 12 VN, 24 VN
for the design with parameter c = 12 VN, 24 VN
for the design with parameter c = 12 VN, 24 VN
for the design with parameter c = 12 VN, 24 VN for designs with parameter c = 220 VU, 230 V
for designs with parameter c = 220 VU, 230 V
for designs with parameter c = 220 VU, 230 V
for designs with parameter c = 220 VU, 230 V
Upwr – supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC (220 VU), supply voltage of 85...253 VAC, 50 Hz (230 V).
Input
Input
Input
InputInput
Input
Input
Input
Upwr
Upwr
Upwr
Upwr
Power supply
Power supply
Power supply
Power supplyPower supply
Power supply
Power supply
Power supply
PI
PI
PIPI
PI PIPI PI
PI PI
PI
PI
to PC
to PC
to PC to PC
to PCto PCto PC to PC
to PC to PC
to PC
to PC
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource Supply
voltagesource
Supplyvoltagesource
Supplyvoltagesource
Supplyvoltagesource
To measuring and control meters
To measuring and control meters
To measuring and control metersTo measuring and control meters
To measuring and control meters
To measuring andcontrol metersTo measuring and
control meters
SchCh02 SchCh02
SchCh72SchCh72
SchCh96SchCh96
SchCh120SchCh120
86 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Type Overall dimensions, mm Sign height, mm Weight, kg, maximum
SchCh00P 48 × 24 × 90 9.9 0.2
SchCh01P 96 × 24 × 90 9.9 0.2
SchCh02.01P 96 × 48 × 90 20 0.3
SchCh00P, SchCh01P, SchCh02.01P
Digital frequency meters SchCh00P, SchCh01P, SchCh02.01P are intended to measure and convert AC frequency in one-phase electrical circuits and other AC circuits into output unified DC signals and to transmit measured values through serial digital interface RS485.
The digital meters are single-channel and single-scale meters with designs by overall dimensions, input voltage measurement ranges, supply voltage, availability of interface, digital and analogue outputs, indicators colour.
The panel digital frequency meters are used in the energy industry and other sectors of industry for control of electrical parameters.
Accuracy class – when measuring input signal frequency – 0.05;– when converting – 0.5
Temperature range (operating) -40 °С…+50 °С
Maximum indication range 0...9999Frequency measurement range 10...9999 Hz
Frequency conversion range* 45 ... 55 Hz (by default)
Number of measuring channels 1
Number of displayed parameters 1
Galvanic isolation of input and output circuits, power circuits
The meters have galvanic isolation in the power circuit, output circuits (SchCh00P meters have no galvanic isolation in interface RS circuit)
Front frame protection level IP50
Interface RS485 (protocol Modbus RTU) Quantity: 0 or 1
Interface exchange rate 9600, 19200, 38400, 57600 bit/s.
Analogue output (accuracy class 0.5) Quantity: 0, 1, 2Ranges: 0...5 mA, 4…20 mA, 0...20 mA,0…2.5…5 mA, 4…12…20 mA, 0…10…20 mA
Load resistance, kΩ 0.5 (for 4...20 mA, 0...20 mA, 4…12…20 mA, 0…10…20 mA)2.5 (for 0...5 mA, 0…2.5…5 mA)
Digital output Quantity: 0; 1; 2;DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Maximum permissible input signal overload 150%
Time of setting output analogue signal, max 0.5 s
Input resistance at voltage measurement, min. (1±0.005) MΩ
Power supply – 5 V (5±0.25) VDC– 12 V (12 ± 0.6) VDC (with protection against wrong connection of supply voltage polarity)– 24 V (24±1.2) VDC– 5 VN (5+4/-0.5) VDC– 12 VN (12+6/-3) VDC– 24 VN (24 +12/-6) VDC (with protection against wrong connection of supply voltage polarity)– outer unit of balanced supply voltage of 5 V (for SchCh00P meter)SchCh02.01P meters provide power redundant for designs with supply voltage of (12 +6/-3) V and (24 +12/-6) V.
Power consumption, max SchCh00P – 1.7 VA; SchCh01P – 2.7 VA; SchCh02.01P – 3.2 VA
Calibration interval 10 years
Guarantee period 36 months
Mean life, min 20 years
Mean time between failures 200000 hours
* Frequency conversion range may be of any value within the frequency measurement range.
87Catalogue of Products
www.elpribor.ru
Ordering examples
Order form
SchCh00P – 250V – × – × – × – З – 4.0, TU 25-7504. 228-2015SchCh00P meter, input voltage of 250 V, with outer unit of balanced supply voltage of 5 V without interface, analogue and digital outputs; green indication, digit 4.0.
SchCh01P – 250V – 12V – 1RS – × – З – 4.0, TU 25-7504. 228-2015SchCh01P meter, input voltage of 250 V, balanced supply voltage of 12 VDC, one interface RS485, without analogue and digital outputs; green indication, digit 4.0.
SchCha – b – с – d – e – f– g
а – meter type (by the Overall dimension, mm):SchCh00P – 48×24, SchCh01P – 96×24, SchCh02.01P – 96×48,
b – reference designation of input voltage range:250 V – For the meters SchCh00P, SchCh01P,150 V, 500 V – for SchCh02.01P meter,
c – reference designation of supply voltage:– 5 V (5±0.25) VDC– 12 V (12 ± 0.6) VDC (with protection against wrong connection of supply voltage polarity)– 24 V (24±1.2) VDC– 5 VN (5+4/-0.5) VDC– 12 VN (12+6/-3) VDC– 24 VN (24 +12/-6) VDC (with protection against wrong connection of supply voltage polarity)– outer unit of balanced supply voltage of 5 V(for SchCh00P meter)
d – availability of interface RS485:1RS – one interface,× – no interface;
e – reference designation of analogue and digital outputs01 – one digital outputs without analogue outputs,10 – one analogue output without digital input,11 – one analogue and one digital output,12 – one analogue and two digital outputs,20 – two analogue outputs without digital ones,22 – two analogue and two digital outputs,х – without analogue and digital outputs
Note – the reference designation of analogue output is specified after figures in brackets: А – 0...5 mA, B – 4...20 mA, С – 0...20 mA, АР – 0…2.5…5 mA, ВР – 4…12…20 mA, СР – 0…10…20 mA, when ordering two analogue outputs, specify it separated by a comma;
f – indicators colour:R – red,G – green,Y – yellow;
g – digit:4.0 (measurement range – 10...9999 Hz; accuracy class – 0.05).
Connection diagrams
SchCha meter type
Full reference designation code parameter
b c d e f g h
SchCh00P 250 ×, 5V, 12V, 24V ×, 1RS × + 4,0 +
SchCh01P 250 5V, 12V, 24V ×, 1RS ×, 01, 10, 11 + 4,0 +
SchCh0.01P 150, 500 5VN, 12VN, 24VN 1RS ×, 12, 20, 22 + 4,0 +
NoteSign “+” means that availability of all possible versions of a parameter in the order formula.Sign “x” means that no parameter is available in the order formula.For SchCh00P meter, interface RS485 without galvanic isolation.
SchCh00P
SchCh01P
SchCh0.01P
Input
Input
Input Power supply
Power supply
Power supply
PI
PI
PI
to PC
to PC
to PC
Inputsignal source
Inputsignal source
Inputsignal source
Supply voltage source
Supply voltage source
Supply voltage source
To measuringand control
meters
SchCh00P
SchCh01P
SchCh02.01P
To m e a s u r i n g a n d c o n t r o l m e t e r s
88 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
SchCh00P
SchCh01P
SchCh02.01P
Cutout (1:2)
Cutout
Cutout
bracket
bracket
bracket
bracket
Screw М3x16
Screw М3x16
89Catalogue of Products
www.elpribor.ru
LTC power transformer position indicators
SchUP96, SchUP120
Order form
SchUP96, SchUP120 indicators are intended to convert sensors signal of switching meters of transformers under load into a digital signal to display a position number on a digital indicator.
The indicators are installed on the control panel and suitable for installation on Bulgaria drives MZ-2, MZ-4 and on any other drives with a resistance pickup.
It may be used as a resistance meter. Four-wire connection.
Type Overall dimensions, mm, max Panel cutout, mm Sign height, mm,
min Weight, kg, max.
SchUP9696х96х103(w/ rear cover)
92х92 20 0.4
SchUP120120х120х103(w/ rear cover)
112х112 20 0.6
Maximum number of stages 2...99
Stage resistance 5...20 Ω (with pitch 1 Ω)
Maximum measured resistance 1000 Ω (999.9)
Working Temperature range (operating)(climatic model O4.1)(climatic model UKhL3.1)
+5 °С ...+50 °С-40 °С ... +55 °С
Maximum current of relay output 100 mA
Maximum permissible voltage on relay output terminals 300 V (by amplitude)
Interface RS485 (protocol Modbus RTU)
Front frame protection level IP2Х
Power supply voltage85...242 VAC, (50±0.5) Hz or 120 ...265 VDC
Power consumption 7 V•A
Mean time between failures, min 10000 h
Mean life, min 10 years
SchUP120 – 6 – RS – R – UKhL 3.1 TU 25-7504.205-2008The SchUP120 indicator, stage resistance of 6 Ω, interface RS485, red indicators, working Temperature range (operating) -40 °С ...+55 °С.
Ordering example
SchUP a – b – c – d – е
а – meter type (by dimensions):96; 120
b – stage resistance value*:5...20* – with the absence in the order, by default 6 Ω is accepted
c – interface:RS – interface RS485 (Modbus RTU);х – in case of interface absence,, it is not specified
d – indicators colour:R – red G – green Y – yellow
e – climatic model:О4.1 – +5 °C ...+50 °C; UKhLЗ.1 – -40 °C ... +55 °C
Connection diagrams
Input
Upwr
SchUP96, SchUP120 indicatorsOutput 1 Output 2
Digitaloutputs
PI
to PC
90 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
SchUP96
SchUP120
Overall and mounting dimensions
Cutout (1:2)
Cutout (1:2)
CutoutRear view with no cover
91Catalogue of Products
www.elpribor.ru
Type Overall dimensions, mm, max.
Sign height, mm, min. Weight, kg, maximum
SchUP120U 120 x 120 x 103(w/ rear cover) 20 0.6
SchUP120U
Ordering examples
Order form
SchUP120U is subsequent development of series-produced SchUP120 indicator. It is installed on the control panel and structurally compatible with the standard pointer quotient-meter of UP30 type.
The indicator is suitable for installation on Bulgaria drives MZ-2, MZ-4 instead of stages indicator of LKM type, on Germany drives MR, EM and ED-S, as well as on any other drives with the resistive pickup or the pickup with an output signal “current loop”. The indicator operates in combination with the selsyn transmitter of drive turn angle type BD404 or BD1404 and suitable for installation on all drives (types RNT 13, PDP-1, PDP-4, etc.).
SchUP120U is provided with setting maximum permissible drive positions. Presence of digital and analogue output signals allows transmitting data on a drive stage to telemechanics systems, ADCS, SSE (stepped start equipment).
Minimum full resistance of resistive pickup 25 Ω
Voltage supplied to the resistive pickup +5 V
Voltage supplied to the selsyn transmitter 24…27 V
Temperature range (operating) -40 °С... +50 °С
Interface RS485 (Modbus RTU)
Interface exchange rate9600 baud. – by default;4800, 19200, 38400 baud. – user re-programmable
Analogue output4…20 mA – by default;0...20 mA, 0…5 mA – user re-programmable
Relay output 300 V, 100 mA
Front frame protection level IP20
Indicator supply voltage 220 V, 50 Hz
Power consumption 15 V•А
Mean time between failures, min 10000 h
Mean life, min 10 years
SchUP120U – TP (А), lock, RV – R – 10 – 5R TU 25-7504.214-2011SchUP120U indicator with the following characteristics: availability of input signal “current loop” of 0...5 mA, interlocking output, relay output, red indicators, a number of drive positions is 10, pickup stage resistance is 5 Ω.
SchUP120U – х – З – 20 – 10°С TU 25-7504.214-2011SchUP120U indicator has the following characteristics: green indicators, a number of drive positions is 20, angle value between stages for pickups with the selsyn transmitter is 10°С.
SchUP120U a – b – c – d
a – TP (х), lock, RV availability:TP (х) – sensor of output signal type“current loop”, where х – А (0...5 mA),В (4...20 mA), С (0...20 mA)Lock – module for interlocking of maximum permissible positions of drive RPNRV – relay outputх – no parameter
b – indicators colour:R – redG – green
c – number of drive positions:1... 99 (Customer’s selection)
d – angle between stages or stage resistance value: Х°С – stage value in degrees with the selsyn transmitterYR – stage value in Ω for drives with the resistive pickup
Connection diagrams
not used
not used
not used
not used
not used
Tx transmission
Rx reception
general RS232
general RS485
to contact Р1/-TP
to contact Р2/+TP
to contact Р3
to contact С1
to contact Р1
to contact Р2
to contact Р3
to contact C2
to contact Р1/-TP
to contact Р2/+TP
to contact Р3
to contact С1
to contact Р1
to contact Р2
to contact Р3
to contact C2
power +24 V
TP power
TP output
TP general
power -220 V
power -220 V
general control
switching “Turn down”
switching “Turn up”
last stage
first stage
interlocking “Turn down”
interlocking “Turn up”
general control
cont
rol c
ircui
tsTP
0…
20 m
A
to B
CD
-sen
sor
to th
e se
lsyn
tra
nsm
itter
to th
e re
sist
ive
pick
up/T
P~2
20V
SchUP120U
92 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
Panel cutout (1:2)
93Catalogue of Products
www.elpribor.ru
METERS FOR Direct current and direct voltage MEASUREMENT AND
Sch02P, Sch72P,Sch96P, Sch120P
Sch02P, Sch72P, Sch96P, Sch120P meters are intended to measure and convert current and voltage in DC circuits into output unified DC signals and serial digital interface RS485, which allow using the meters in automated systems of various purposes.
The meters provide the possibility for programming with built-in buttons or through the interface: indication range, decimal point position; level of the controlled values of input signals (settings); change in brightness of digital indicators illumination; interface parameters.
Sch120P meets the requirements of PJSC ROSSETI and PJSC FGC UES, they are recommended for the use at facilities of JSC ROSSETI and PJSC FGC UES.
Type Overall dimensions, mm Panel cutout, mm Sign height, mm Weight, kg, max.
Sch02P 96 х 48 х 122 90 х 42 14 0.4
Sch72P 72 х 72 х 76 68 х 68 10 0.2
Sch96P 96 х 96 х 76 92 х 92 14 0.5
Sch120P 120 х 120 х 76 112 х 112 20 0.5
Accuracy class 0.1 or 0.2
Rated voltagemV: 60, 75, 100, 150, 200, 250, 500, 1000, 2000V: 1, 2, 5, 10, 2…10, 20, 50, 100, 150, 200, 250, 500, 750
Rated currentmA: 2, 5, 10, 20, 4…20, 50, 100, 200, 500, 1000А: 1, 2
Temperature range (operating) -40 °С... +70 °С UKhL3.1
Maximum indication range -19999...+19999
Number of measuring channels 1
Galvanic isolation of input and output circuits, power circuits
Yes
Front frame protection level IP50
Interface RS485 (protocol Modbus RTU)– basic for data transmission– additional for data transmission or connection of the display and Display panel (MI120, MI80)
Interface exchange rate 4600, 9600, 19200, 38400 bit/s.
Analogue output (accuracy class 0.5)Quantity: 0; 1; 2;Ranges: 0...5 mA, 4...20 mA, 0…20 mA, 0...2.5...5 mA;4...12...20 mA; 0…10…20 mA
Load resistance2.5 kΩ for ranges of 0...5 mA, 0...2.5...5 mA;0.5 kΩ for ranges of 0...20 mA, 4...20 mA,4...12...20 mA, 0…10…20 mA
Digital outputQuantity: 0; 1; 2;DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Maximum permissible input signal overload (from the upper limit of the measurement range)*
150% (1 minute)
Time of setting output analogue signal, max 1.0 s
Input resistance at load voltage measurement, min. 1 MΩ
Power supply
– 5 VN (5+4/-0.5) VDC,– 12 VN (12+6/-3) VDC,– 24 VN (24+12/-6) VDC,– 220 VU of 85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC– 230 V from 85...253 VAC, (50 ± 0.5) Hz
Power consumption, max 6 V•А
Calibration interval 6 years
Guarantee period 36 months
Mean life 30 years
Mean time between failures 150000
94 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
Order form
Sch120P – 100 V – 220 VU – 2 RS – 22(А,С) – R – 0.2 TU 25-7504.218-2012Note: indication range -20…+50 °СFor Sch120P meter, measurement range minus 100 to plus 100 V, supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC, two interfaces RS485, two analogue outputs 0…5 mA and 0…20 mA, two digital output, red indicators, accuracy class 0.2, indication range -20…+50 °С.
Overall and mounting dimensions
Sch – meter type (by the Overall dimension, mm):Sch02P – 96×48,Sch72P – 72×72, Sch96P – 96×96, Sch120P – 120×120,
b – measurement range for the input signal with direct connection or transformation factor with connection through the outside shuntmV: 60, 75, 100, 150, 200, 250, 500, 1000, 2000V: 1, 2, 5, 10, 2…10, 20, 50, 100, 150, 200, 250, 500, 750mA: 2, 5, 10, 20, 4…20, 50, 100, 200, 500, 1000А: 1, 2Note: if the indication range differs from the measurement range the input signal and from the shunt conversion factor, give additionally the ordered indication range in the note to the order formula.
c – reference designation of supply voltage:5 VN, 12 VN, 24 VN, 220 VU, 230 V
d – availability of interfaces RS485:1RS – one interface,2RS – two interfaces,х – with the absence of parameter (for Sch120P only)
e – reference designation of analogue and digital outputs:02 – two digital outputs without analogue output,11 – one analogue and one digital output,12 – one analogue and two digital outputs,20 – two analogue outputs without digital ones,22 – two analogue and two digital outputs,х – without analogue and digital outputs
Note: the reference designation of analogue output is specified after figures in brackets: А = 0...5 mA, В = 4...20 mA, С = 0...20 mA,АР = 0…2.5…5 mA, ВР = 4…12…20 mA, СР = 0…10…20 mA,when ordering two analogue outputs, specify it separated by a comma.
f – indicators colour:R – red, G – green, Y – yellowg – accuracy class: 0.1 or 0.2
h – special design:ОМ2 – meters for marine application,А – for operation at NPP (safety class 4), do not specify in other cases.
TypeFull reference designation code parameter
b с d e f g h*
Sch02P + + 1RS х, 12, 20, 22 + + +
Sch72P + + 1RS х, 02, 11, 20 + + +
Sch96P + + 1RS, 2RS х, 12, 20, 22 + + +
Sch120P + +х,1RS, 2RS
х, 12, 20, 22 + + +
* For the meters with special design, accuracy class 0.2.NotesSign “+” means that availability of all possible versions of a parameter in the order formula.Sign “x” means that no parameter is available in the order formula.
Type HхН1, mm L, mm,max(w/ cover)
L1, mm, max(w/o cover) A , mm B, mm
Sch02P 96х48 148 122 100х5092+0.8 х45+0.6
Sch72P 72х72
103 76
75 68+0.7
Sch96P 96х96 100 92+0.8
Sch120P 120х120 125 112+0.9
Sch а – b – c – d – е – f – g – h
Panel cutout
95Catalogue of Products
www.elpribor.ru
Sch02P
Connection diagrams
for the design with parameter с = 5 VN, 12 VN, 24 VN
Sch72P
for the design with parameter с = 5 VN, 12 VN, 24 VN for design with parameter с = 220 VU, 230 V
Upwr – supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC (220 VU), supply voltage of 85...253 VAC, 50 Hz (230 V).
for design with parameter с = 220 VU, 230 V
Upwr – supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC (220 VU), supply voltage of 85...253 VAC, 50 Hz (230 V).
Input
Input Input
Input
Upwr
Upwr
Power supply
Power supply Power supply
Power supply
PI
PI PI
PI
to PCto PC
to PC to PC
Inputsignal source
Inputsignal source
Inputsignal source
Inputsignal sourceSupply
voltage source
Supply voltage source
To m e a s u r i n g a n d c o n t ro l m e t e r sTo m e a s u r i n g a n d c o n t ro l m e t e r s
To m e a s u r i n g a n dc o n t ro l m e t e r s
To m e a s u r i n g a n dc o n t ro l m e t e r s
Sch02P
Sch72P Sch72P
Sch02P
96 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
for design with parameter с = 220 VU, 230 V
Upwr – supply voltage of 85 to 253 VAC, 50 Hz or 120 to 265 V DC (220 VU), supply voltage of 85 to 253 VAC, 50 Hz (230 V).
for design with parameter с = 220 VU, 230 V
Upwr – supply voltage of 85 to 253 VAC, 50 Hz or 120 to 265 V DC (220 VU), supply voltage of 85 to 253 VAC, 50 Hz (230 V).
for the design with parameter с = 5 VN, 12 VN, 24 VN
Sch120P
for the design with parameter с = 5 VN, 12 VN, 24 VN
Sch96P
Input
InputInput
Input
Upwr
Upwr
Power supply
Power supply Power supply
Power supply
PI
PIPI PI PI
PIPIPI
to PCto PC
to PC to PC to PC to PC
to PC to PC
Inputsignalsource
Inputsignalsource
Inputsignalsource
Inputsignalsource Supply
voltagesource
Supply voltage source
To m e a s u r i n g a n d c o n t ro l m e t e r s To m e a s u r i n g a n d c o n t ro l m e t e r s
To measuring and control meters
Sch96P Sch96P
Sch120PSch120P
To measuring and control meters
97Catalogue of Products
www.elpribor.ru
SMALL DIGITAL DC METERS
Type Overall dimensions, mm Sign height, mm Weight, kg, maximum
Sch00P 48 × 24 × 90 9.9 0.2
Sch01P 96 × 24 × 90 9.9 0.2
Sch02.01P 96 × 48 × 90 20 0.3
Sch02.00 96 × 48 × 64 9.9 0.2
Sch00P, Sch01P,Sch02.01P, Sch02.00
Digital meters Sch00P, Sch01P, Sch02.01P, Sch02.00 are intended to measure and convert a value of current and voltage in one-phase electrical circuits and other DC circuits into output unified DC signals and to transmit measured values through serial digital interface RS485 (if any).
The meters are single-channel and single-scale meters with designs by overall dimensions, measurement ranges, indication ranges, supply voltage, availability of interface, digital and analogue outputs, indicators colour, accuracy class, custom design.
The digital ammeters and voltmeters are used in the energy industry and other sectors of industry for control of electrical parameters.
The possibility for data exchange through interface RS485 (except for Sch02.00), availability of output analogue DC signals and digital outputs allow using the digital meters in automated systems of various purposes.
Accuracy class – when measuring DC intensity and voltage – 0.1 or 0.2;– when converting – 0.5.
Input signal mV: 60, 75, 100, 150, 200, 250, 500, 1000, 2000V: 1, 2, 5, 10, 2…10, 20, 50, 100, 150, 200, 250, 300 (except for Sch00P),500 (except for Sch00P); 750 (except for Sch00P, Sch01P)mA: 2, 5, 10, 20, 4…20, 50, 100, 200, 500, 1000, 2000А: 1, 2
Temperature range (operating) -40 °С…+50 °С
Maximum indication range Sch01P, Sch02.01P: 9999 ...+9999, Sch00P: 1999 ... + 9999,Sch02.00: 1999 ...+ 1999.
Frequency range measured signals 45...65 Hz
Number of measuring channels 1
Number of displayed parameters 1
Galvanic isolation of input and output circuits, power circuits
The meters have galvanic isolation in the power circuit, output circuits (Sch00P meters have no galvanic isolation in interface RS circuit).
Front frame protection level IP50
Interface RS485 (protocol Modbus RTU) Quantity: 0 or 1
Interface exchange rate 9600, 19200, 38400, 57600 bit/s.
Analogue output (accuracy class 0.5) Quantity: 0, 1, 2Ranges: 0...5 mA, 4...20 mA, 0…20 mA, 0...2.5...5 mA,4...12...20 mA, 0…10…20 mA
Load resistance, kΩ 0.5 (for 4...20 mA, 0...20 mA, 4…12…20 mA, 0…10…20 mA)2.5 (for 0...5 mA, 0…2.5…5 mA)
Digital output Quantity: 0; 1; 2;DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Maximum permissible input signal overload 150% (2 hours)
Time of setting output analogue signal, max 0.5 s
Input resistance at voltage measurement, min.
(1±0.005) MΩ
Power supply – 5 V (5±0.25) VDC,– 12 V (12±0.6) VDC,– 24 V (24±1.2) VDC,– 5 VN (5+4/-0.5) VDC,– 12 VN (12+6/-3) VDC,– 24 VN (24+12/-6) VDC;– outer unit of balanced supply voltage of 5 V (for Sch00P meter)
Power consumption, max Sch00P – 1.7 VA; Sch01P – 2.7 VA; Sch02.01P – 3.2 VA; Sch02.00 – 2.5 VA
Calibration interval 10 years
Guarantee period 36 months
Mean life, min 20 years
Mean time between failures 200000 hours
98 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
Order form
Sch00P – 10 mA – × – × – × – R – 0.1 TU 25-7504.228-2015Sch00P meter, measurement range minus 10 to plus 10 mA, with outer unit of balanced supply voltage of 5 V without interface, analogue and digital outputs; red indicators, accuracy class 0.1.
Sch01P – 200А/75mV – 12V – 1RS – × – R – 0.1 TU 25-7504.228-2015Sch01P meter, conversion factor of 200 A/75 mV, supply voltage of 12 VDC (balanced), one interface RS485, without analogue and digital outputs, red indicators, accuracy class 0.1.
Scha – b – с – d – e – f – g – h
Sch – meter type (by the Overall dimension, mm):Sch00P – 48×24, Sch01P – 96×24,Sch02.01P, Sch02.00 – 96×48,
b – reference designation of measurement range with direct connection or transformation factor with connection through the outside shuntmV: 60, 75, 100, 150, 200, 250, 500, 1000, 2000V: 1, 2, 5, 10, 2…10, 20, 50, 100, 150, 200, 250, 300(except for Sch00P); 500 (except for Sch00P), 750 (except for Sch00P, Sch01P)mA: 2, 5, 10, 20, 4…20, 50, 100, 200, 500, 1000, 2000А: 1, 2Note: if the indication range differs from the measurement range the input signal and from the shunt conversion factor, give additionally the ordered indication range in the note to the order formula.
c – reference designation of supply voltage:5V, 12V, 24V, 5VN, 12VN, 24VN,× – with outer unit of balanced supply voltage5 V (for Sch00P meters);d – availability of interface RS485:1RS – one interface,× – no interface;
e – reference designation of analogue and digital outputs:01 – one digital outputs without analogue outputs,10 – one analogue output without digital input,11 – one analogue and one digital output,12 – one analogue and two digital outputs,20 – two analogue outputs without digital ones,22 – two analogue and two digital outputs,х – without analogue and digital outputs
Note: the reference designation of analogue output is specified after figures in brackets: А = 0...5 mA, В = 4...20 mA, С = 0...20 mA,АР = 0...2.5...20 mA, ВР = 4…12…20 mA,CР – 0…10…20 mA, when ordering two analogue outputs, specify it separated by a comma.
f – indicators colour:R – red,G – green,Y – yellow;
g – accuracy class:0.1 or 0.2;Note – for Sch02.00 meter, accuracy class 0.2 only;
h – special design:А – for operation at NPP (safety class 4),– with the absence of custom design parameter is not specified.
Connection diagrams
TypeFull reference designation code parameter
b с d e f g h
Sch00P + ×, 5В, 12В, 24В ×, 1RS × + + +
Sch01P + 5В, 12В, 24В ×, 1RS ×, 01, 10, 11 + + +
Sch02.01P +5ВН, 12ВН,24ВН
1RS ×, 12, 20, 22 + + +
Sch02.00 + 5В, 12В, 24В × × + 0,2 +
NotesSign “+” means that availability of all possible versions of a parameter in the order formula.Sign “.” means that no parameter is available in the order formula.Unused parameter h is not specified.For Sch00P meter, interface RS485 without galvanic isolation.
Sch00P Sch02.00
Sch01P
Input
Input
Power supply
Power supply
PI
PI
to PC
to PC
Inputsignal source
Inputsignal source Input
signal source
Supply voltage source
Supply voltage source
To measuringand control
meters
Sch00PSch02.00
Sch01P
99Catalogue of Products
www.elpribor.ru
Габаритные и установочные размеры
Sch00P
Sch01P
Sch02.01P
Overall and mounting dimensions
Cutout (1:2)
Cutout
bracket
bracket
Screw М3x16
Input Power supply
PI
to PC
Inputsignal source Supply
voltage source
To m e a s u r i n g a n d c o n t r o l m e t e r s
Sch02.01P
100 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Sch02.01P
Sch02.00
Cutout
bracket
bracket
BracketScrew М3x16
Screw М3x16
Panel
Gasket
Plan view
Rear view Panel cutout
101Catalogue of Products
www.elpribor.ru
DIGITAL METERS OF COMBINED INDICATION
К02P.G, К02P.V
Order form
They are intended to measure current intensity or voltage in the electrical DC circuits and to display a current value on built-in digital and digital-analogue indicators.
Maximum display range -1999...9999
Figures height, mm 9
Temperature range (operating) +5 °C... +50 °C
Front frame protection level IP40
Accuracy class 0.1 or 0.2
Conversion time, max. 3 s
Interface RS485 (protocol Modbus RTU)
Interface exchange rate 4800, 9600, 19200, 38400 baud.
Power supply 5 V (5±0.25) VDC12 V (12±0.6) VDC24 V (24±1.2) VDC12 VN (12+6/-3) VDC24 VN (24+12/-6) VDC220 VU from 100...242 VAC,(50 ± 0.5) Hz or 120 ... 260 VDC
Overall dimensions, mm 96 х 48 х 145 (G); 48 х 96 х 145 (V)
Calibration interval 1 year
Guarantee period 2 years
Mean life 10 years
Mean time between failures 50000 hoursK02P.a – b – c – d – е – f – g – h
a – working position:G – horizontalV – vertical
b – measurement range:mA: 2; 5; 10; 20; 50; 100; 200; 500А: 1; 2mV: 60; 75; 100; 150; 200; 500V: 1; 2; 5; 10; 20; 50; 100; 200; 500
c – digit:4.0
d – power:5 V (5±0.25) VDC12 V (12±0.6) VDC24 V (24±1.2) VDC12 VN (12+6/-3) VDC24 VN (24+12/-6) VDC220 VU from 100...242 VAC, (50 ± 0.5) Hz or 120...260 VDC
e – interface:RS – interface RS485 (Modbus RTU);– with the absence, this parameter is not specified
f – reference designation of digital outputs:00 – no digital outputs22 – two digital output with galvanic isolation from each other and from other meter circuits, with switching DC or AC voltage with amplitude of up to 400 V and current of up to 120 mA per each output
g – indicator colour:R – redG – greenY – yellow
h – accuracy class:0.10.2
Connection diagrams
for the designs with parameter d = 5 V, 12 V, 24 V
for the designs with parameter d = 220 VU
for the designs with parameter d = 12 VN, 24 VN
RН – digital output load; Е1, Е2 – load power supply sources RН; PI – interface signals converter; Еp1, Еp2 – DC supply voltage source (main and standby)
RН – digital output load; Е1, Е2 – load power supply sources RН; PI – interface signals converter; Up – supply voltage of 100...242 VAC, 50 Hz or 120 ... 260 VDC
RН – digital output load; Е1, Е2 – load power supply sources RН; PI – interface signals converter; Еp – DC supply voltage source
Input
Input
Input
Upwr
Power supply
Power supply
Power supply
Outputs
Outputs
Outputs
PI
PI
PI
to PC
to PC
to PC
Inputsignal source
Inputsignal source
Inputsignal source
Meter
Meter
Meter
102 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
K02P.V 2 А 4.0 220VU RS 00 R 0.2 TU 25–7504.204–2008K02P meter, vertical, input signal range 0...2 A, supply voltage of 100...242 VAC, (50±0.5) Hz or 120...260 VDC, interface RS485, no digital outputs, red indicators, accuracy class 0.2.
Overall and mounting dimensions
Type HхН1, mm L, mm,max(w/ cover)
L1, mm, max(w/o cover) A, mm B, mm
К02P.G 96х48145 -
100х50 90+0.8 х42+0.6
К02P.V 48х96 50х100 42+0.6х90+0.8
Panel cutout
103Catalogue of Products
www.elpribor.ru
Display
Data display
Т44, Т54, Т74
Order form
Digital data displays are intended to measure and display any electrical and physical values (for example: values of AC or DC, voltage, pressure, temperature, frequency, etc.) and values received as digital parameters through interface RS485 under the control of protocol Modbus RTU.
Parameter Т44 Т54 Т74Sign height, mm 100 140 180
Dimensions, mm 420 х 130 х 40 500 х 170 х 40 585 х 210 х 40
Input signal range
DC and voltage:mV: 60; 75; 100; -75...0...75V: 5; 10; 20; 50; 100; 200; 250; 500mA: 2; 5; 10; 20; 4...20; -5...0...5AC and voltage:mV: 100V: 5; 10; 20; 50; 100; 200; 250; 380; 500mA: 2; 5; 10; 20; 50; 100; 20085...253 V for display of 10...5000 Hz
Error ± 0,5 %
Interface RS485 (protocol ModBus RTU) (9600, 19200, 38400 and 57600 bit/s)
Power consumption, max 15.0 V•A 17.0 V•A 20.0 V•A
Digital outputQuantity: 1DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Power supply voltage 85...253 VAC, (50±0.5) Hz or 120 ...265 V DC
Working temperature +5 °С...+50 °С
Front frame protection level
IP50
Weight 1.2 kg 1.6 kg 2.0 kg
Mean life 10 years
Features:– Maximum range parameter display of minus 1999 to plus 9999;– Change in operation modes setting with the remote control panel or through interface RS485;– Illumination brightness control (12 degrees of brightness);– Setting of min and max parameters;– Programming of input signal parameter, change in display scale;– Formation of digital signals for control of commutation equipment;– Indicators flashing with reaching the preset threshold values;– Possibility for selection of indicator colour when ordering: red, green, yellow.
Dependence of maximum distance from an inspector to the red indicator (in meters) ensuring standard reading of indicated figures (for digital displays with green indicators, this parameter is less twice).
Note:– when ordering the DC display according to the order formula, the following (parameter b) is indicated: 0...Х (where Х is a measurement range);– when ordering the AC display, the end range (parameter b) is indicated: Х (where Х is a measurement range);
Ta – b – c – d – е
a – display type depending on the overall dimensions:Т44 – for indicators height 100 mm; Т54 – for indicators height 140 mm; Т74 – for indicators height 180 mm
b – measurement range for the input signal with direct connection0...Х DC voltage/intensity (Example: 0...100 VDC);Х – AC voltage/intensity; (Example: 100 VAC)85...253 V for display of 10...5000 Hz
c – displayed value range
d – measurement unit of the displayed value
e – indicator colour:R – red,G – green,Y – yellow
0 m 40 m 55 m 65 m
100 mm 140 mm 180 mm
104 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
– DC displayТ44 0…100V 0…100 V R TU 25-7504. 225-2014For DC data display Т44 with the range measured or displayed value of 100 V, measurement unit is V, red indicators.
– AC displayТ44 100V 0…100 V R TU 25-7504. 225-2014For AC data display Т44 with the range measured or displayed value of 100 V, measurement unit is V, red indicators.
Т54 85...253 V 45...65 Hz G TU 25-7504. 225-2014For data display Т54 with the range measured value of 85...253 V and displayed value of 45...65 Hz, measurement unit is Hz, green indicators.
Overall and mounting dimensions
Display design Indicators height, mmOverall dimensions, mm, max Overall setting dimensions,
mm
L Н В
Т44 100 420 130 270
Т54 140 500 170 340
Т74 180 585 210 430
2 holes
105Catalogue of Products
www.elpribor.ru
Display clock
TCh44, TCh54, TCh74
Ordering example
Order form
The display clocks are intended to display current time, date and temperature (depending on the selected range) with supporting function “ring”. Hours and minutes are corrected with the remote control panel type RC-5 and through interface RS485.
Parameter TCh44 TCh54 TCh74Sign height, mm 100 140 180
Dimensions, mm 420 х 130 х 40 500 х 170 х 40 585 х 210 х 40
Display range Temperature: -50°С... +50°С; Clock: 00.00 ...23.59
Error0.1 s/days±2°С from -50°С....-20°С±1°С from -20°С....+50°С
Interface RS485 (protocol ModBus RTU) (9600, 19200, 38400 and 57600 bit/s)
Power consumption, max 15.0 V•A 17.0 V•A 20.0 V•A
Digital outputQuantity: 1;DC voltage 300 V, 100 mA orAC voltage 200 V, 100 mA
Power supply voltage 85...253 VAC, (50±0.5) Hz or 120 ...260 VDC
Working temperature +5 °С...+50 °С
Front frame protection level
IP50
Weight 1.2 kg 1.6 kg 2.0 kg
Mean life 10 years
Features:– Function “ring” with the possibility of programming ring interval, audio signal duration (1...60 s);– Setting of indicators lighting and flashing, illumination brightness control, time and date correction;– Interface RS485 allows setting meter operation modes (time, temperature, date);– Viewing angle 120°; – Maximum display range -50°С ... +50°С, hours of 00.00 ...23.59.
Dependence of maximum distance from an inspector to the red indicator (in meters) ensuring standard reading of indicated figures (for digital displays with green indicators, this parameter is less twice).
The display clock with the red indicationTCh44 R TU 25-7504. 225-2014
Т Ch А - В
A – display type depending on the overall dimensions:Т44 – for indicators height 100 mm;Т54 – for indicators height 140 mm;Т74 – for indicators height 180 mm.
B – indicator colourR – red; G – green; Y – yellow
0 m 40 m 55 m 65 m
100 mm 140 mm 180 mm
106 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
Display design Indicators height, mmOverall dimensions, mm, max Overall setting
dimensions, mmL Н В
ТЧ44 100 420 130 270
ТЧ54 140 500 170 340
ТЧ74 180 585 210 430
2 holes
107Catalogue of Products
www.elpribor.ru
Edgewise meters
PANEL DIGITAL METERS Sch20, Sch21, Sch22, Sch23 FOR NPP IN A METAL CASE
Panel digital meters Sch20, Sch21, Sch22, Sch23 are intended to measure current or voltage in DC circuits (for operation as part of technical means of nuclear power stations (NPP TM) and in other sectors of thhe industry).
The meters could be used complete with primary transducers for measurement non-electrical values if ranges of output electrical signal of primary transducers corresponds to the meters input signal ranges.
Input signal measurement ranges: 0–5 mA; 0–20 mA; 4–20 mA; 0–75 mV; 0–200 mV; 0–1 V; 0–10 V; 2–10 V.
The meters are powered from the DC source of (24 ± 4) V. In this case double pulsation amplitude shall not exceed 1.2 V.
Under climatic conditions the meters belong to articles of TV4.1 design (with expansion of Temperature range (operating) minus 10 to plus 50 °С) intended for operation in the atmosphere of type III according to GOST 15150-69. The meters meets the requirements for electromagnetic compatibility according to GOST R 50746-2000 imposed to group IV of NPP TM (technical means supplied to nuclear power stations and/or radiation hazardous facilities).
A level of industrial interferences when operating meters does not exceed values preset by GOST 30805.22-2013 for equipment of class B. For the level of protection against effect of solid bodies, the meters meet IP code according to GOST 14254-96.
Mean time between failures is 150000 hours min. The meters service life is at least 15 years.
All meters are made in a metal case and fire-proof, have no mobile parts and provides resistance to mechanical effects according to group М40, seismic resistance of 9 points provided installation above zero position up to 10 m, 8 points at the installation level of up to 25 m according to GOST 17516.1-90, belong to category I of seismic resistance according to NP-031-01.
The meters are made in a metal case with panel fastening. The fastening design is rated for installation in the panel of 50 mm in thickness. According to the order, installation is possible in a panel with other thickness.
The meters intended for NPP may be used in the security system and systems of normal operation; depending on the order they meet safety classes 2, 3, 4 and have classification designation 2NU, 3NU according to OPB-88/97 NP-001-97.
Working conditions of operation:– ambient air temperature of minus 10 to plus 50 °С;– relative air humidity of 98 % max. at plus 35 °С;– atmospheric pressure is 84...106.7 kPa;– supply voltage of (24±4) VDC.
The meters provide the possibility to select the measurement range input signal and to change the range indications and name of measurement unit.
Meters Sch21.3, Sch22.4, Sch22.6, Sch23.3, Sch23.4, Sch23.6 provide the possibility to program thresholds for change in colour of indication of digital-analogue indicating device.
Meters Sch20.3, Sch21.7, Sch23.7, Sch23.8 provide the possibility to set areas of colour warning of digital-analogue indicating device, which are formed with a number of single indicators of each colour preset in case of order.
Sch20.1 Sch20.3
Sch21.1 Sch21.2
Sch21.3 Sch21.5
Sch21.7 Sch22.1
Sch22.2 Sch22.4
Sch22.5 Sch22.6
Sch23.3 Sch23.4
Sch23.6 Sch23.7
Sch23.8 PN-2
108 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Measured valueInput signal measurement ranges
Group of input signal measurement rangesdesign 1
(single polarity)design 2
(double polarity)DC voltage 0...75 mV -75…0…75 mV -
0...200 mV -200…0…200 mV -
0...1 V -1…0…1 V -
0...10 V -10…0…10 V I
2...10 V -6…2…10 V
Direct current 0...5 mA -5…0…5 mA -
0...20 mA -20…0…20 mA ll
4...20 mA -12…4…20 mA
Type Maximum indication range digital indicating device*
Number of indicators of digital indicating device
Number of single indicators of digital-analogue indicating meters, indicator type**
Type of digital-analogue indicating device
Meters with digital indicating deviceSch20.1 -1999...9999 4 – –
Sch21.1 -1999...9999 4 – –
Sch21.2 -19999...19999 5 – –
Sch21.5 -9999...9999 4 and sign “-” – –
Sch22.1 -1999...9999 4 – –
Sch22.2 -19999...19999 5 – –
Sch22.5 -9999...9999 4 and sign “-” – –
Meters with digital-analogue indicating deviceSch20.3 – – 30, column line
Sch21.3 – – 31, column (mark) line
Sch21.7 – – 62, mark (column) line
Sch23.3 – – 61, column (mark) arch
Sch23.7 – – 102, mark (column) arch
Meters with digital and digital-analogue indicating meters
Sch22.4 -1999...9999 4 25, column (mark) line
Sch22.6 -9999...9999 4 and sign “-” 25, column (mark) line
Sch23.4 -1999...9999 4 61, column (mark) arch
Sch23.6 -9999...9999 4 and sign “-” 61, column (mark) arch
Sch23.8 -9999...9999 4 and sign “-” 102, mark (column) arch
* – indication range may be changed by the Customer with a setting panel;** – factory setting is given without brackets
109Catalogue of Products
www.elpribor.ru
Type
Programmed parameters
Input signal measurement
ranges
Indication range digital indicating
device
Indicators illumination brightness
Thresholds of colour change and indication colour
of digital-analogue indicating device
Type of digital-analogue indicating
device indicator
Meters with digital indicating deviceSch20.1 + + + - -
Sch21.1 + + + - -
Sch21.2 + + + - -
Sch21.5 + + + - -
Sch22.1 + + + - -
Sch22.2 + + + - -
Sch22.5 + + + - -
Meters with digital-analogue indicating deviceSch20.3 + - + - -
Sch21.3 + - + + +
Sch21.7 + - + - +
Sch23.3 + - + + +
Sch23.7 + - + - +
Meters with digital and digital-analogue indicating metersSch22.4 + + + + +
Sch22.6 + + + + +
Sch23.4 + + + + +
Sch23.6 + + + + +
Sch23.8 + + + - +
Notes:1 Sign “+” means that the parameter is programmable.2 Sign “-” means that the parameter is non-programmable.
Connection diagrams
main diagram of meter connection when measurinng input signal
main diagram for meter connection during parameters check, calibration,
programming
K – calibratorPSU – power supply unitPV1 – combined digital meter
Inputsignal source
Power supply
unit Setting panel PN-2
Meter Meter
PSU
110 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Order form
Scha – b – c – d – e – f – g – h – i – j
where Scha – meter type (by the Overall dimension, mm):Sch20 – 50.25,Sch21 – 100.25,Sch22 – 100.50,Sch23 – 100.100;
b – meter design by the view of indicating device, indication range digital indicating device and a number of single indicators of digital-analogue indicating device:1 – digital indicating device with indication range –1999 ... 9999,2 – digital indicating device with indication range ±19999,3 – digital-analogue indicating device with a number of single indicators of up to 61,4 – digital indicating device with the indication range –1999... 9999 and digital-analogue indicating device with a number of single indicators of up to 61,5 – digital indicating device with indication range ±9999,6 – digital indicating device with the indication range ±9999 and digital-analogue indicating device with a number of single indicators of up to 61,7 – digital-analogue indicating device with a number of single indicators over 61,8 – digital indicating device with the indication range ±9999 and digital-analogue indicating device with a number of single indicators over 61.
с – structural meter design:G – horizontal;V – vertical
d – measurement range input signal
e – indication range
f – measurement unit of the displayed value
g – front frame colour:W – white,Gr – grey,B – black
h – front frame colour:W – white,G – grey,B – black
i – colour of indicators of digital indicating device:R – red,Y – yellow,G – green
j – parameters of digital-analogue indicating device:– thresholds of colour change and indication colour (R – red, Y – yellow, G – green) For the meters Sch21.3, Sch22.4, Sch22.6, Sch23.3, Sch23.4, Sch23.6 (from the beginning of the indication range),– number and colour (R – red, Y – yellow, G – green) of single indicators of each alarm area For the meters Sch20.3, Sch21.7, Sch23.7, Sch23.8 (from the beginning of the indication range).
Unused parameter i in the order formula is replaced with sign “x”.Unused parameters c and j are not specified.
The following is additionally specified:1) safety class, classification designation according to OPB-88/97 NP-001-97 (2NU, 3NU or 4);2) thickness of a panel for installation of the meter if it differs from 50 mm;3) language if marking and (or) Operation Manual, Calibration Method shall be prepared in English, Russian is by default;4) number of copies of Operation Manual, Calibration Method.
Sch meter type
Full reference designation code parameter
b с d e f g h i j
Sch201 – + + + + + + –
3 G (V) + + + + + – +
Sch21
1 – + + + + + + –
2 – + + + + + + –
3 G (V) + + + + + – +
5 – + + + + + + –7 G (V) + + + + + – +
Sch22
1 – + + + + + + –
2 – + + + + + + –4 G (V) + + + + + + +
5 – + + + + + + –
6 G (V) + + + + + + +
Sch23
3 – + + + + + – +
4 – + + + + + + +
6 – + + + + + + +
7 – + + + + + – +
8 – + + + + + + +NotesSign “+” means a parameter is available in the order formula. Sign “–” means that no parameter is available in the order formula.
111Catalogue of Products
www.elpribor.ru
Ordering examples
Sch22.2–0...5 mA – minus 20.00...plus 50.00-°С-W-B-G, TU 25-7504.210-2010, safety class – 2N.Sch22.2, Overall dimension is 100х50 mm, digital indicating device with maximum value of indication range 19999, input signal range 0...5 mA, indication range minus 20 ... plus 50, measurement unit – °С, front panel colour – white, front frame colour – black, indication colour – green, safety class – 2N.
Sch22.4.G-0...5mA-minus 20.00...plus 50.00-°С-W-B-R-minus 20 (R), minus 10 (Y), 0 (G), plus 30 (Y), plus 40 (R), TU 25-7504.210-2010, safety class – 4.Sch22.4, Overall dimension is 100х50 mm, digital and digital-analogue indicating device, structural design - horizontal, measurement range input signal of 0...5 mA, indication range minus 20 ... plus 50, measurement unit – °С, front panel colour – white, front frame colour – black, digital indicators colour – red, thresholds of indication colour change – minus 20 – red, minus 10 – yellow, 0 – green, plus 30 – yellow, plus 40 – red, safety class – 4.
Sch20
1 – front frame,2 – front panel,3 – indicators of digital indicating device,4 – unit of measurement,5 – indicators of digital-analogue indicating device,6 – scale of digital-analogue indicating device,7 – label with data on meter design, contacts marking for connection of input signal and supply voltage,8 – screw M2 for the access to a built-in button when programming Sch20.3 meter,9 – connector for connection of input signal and supply voltage.
Overall and mounting dimensions
Sch20.1 Sch20.3G
Sch20.3V 100 (Sch20.1), 90 (Sch20.3)122 (Sch20.1), 110 (Sch20.3)
112 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Sch21
1 – front frame,2 – front panel,3 – indicators of digital indicating device,4 – unit of measurement,5 – indicators of digital-analogue indicating device,6 – scale of digital-analogue indicating device,7 – label with data on meter design, contacts marking for connection of input signal and supply voltage,8 – cover under which there is a wafer for installation of jumpers,9 – connector for connection of input signal and supply voltage.
Sch22
Sch21.1
Sch21.2 Sch21.3G
Sch21.7GSch21.5
Sch21.3V Sch21.7V 100, 90 (Sch21.7)122, 110 (Sch21.7)
Sch22.1 meter
Sch22.4G meter
Sch22.2 meter
Sch22.4V meter
Panel cutout
Clamp
Clamp
Socket
113Catalogue of Products
www.elpribor.ru
Sch23
1 – front frame,2 – front panel,3 – unit of measurement,4 – scale of digital-analogue indicating device,5 – indicators of digital-analogue indicating device,6 – indicators of digital indicating device,7 – cover under which there is a wafer for installation of jumpers;8 – connector for connection of input signal and supply voltage;9 – label with data on meter design, contacts marking for connection of input signal and supply voltage.
Sch23.3 Sch23.3, Sch23.6 Sch23.7
Sch23.8
114 Electrical digital meters
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Power supply units for digital meters
Kits of setting tools
BPI5-1
KSN 1, KSN 2
They are intended for supply of digital meters with supply voltage of +5 V.
Overall dimensions 96 х 48 х 90 mm. Weight 0.3 kg.
* 85...253 VAC, 50 Hz or 100 ...265 VDC.Units BPI5-1 for the group power of meters have galvanic isolation by power.
Ordering examples
BPI5-1, 3 А TU 25-7504.166-2003For the single-channel pulse power supply unit, channel load current is 3 A, Uout = 5 V.
They are intended for setting panel digital meters with the possibility to change parameters through interface RS485.
Kit of setting tools 1
It includes the following:– interface transducer (USB in RS422/485 MOXA UPort 1130 with adapter from connector DB9 to terminals);– software;– Operation Manual.
Kit of setting tools 2
It includes the following:– laptop;– interface transducer (USB in RS422/485 MOXA UPort 1130 with adapter from connector DB9 to terminals);– software;– Operation Manual.
Power supply unit type Supply voltage, V Output voltage, V Load current Output power, VA
BPI5-1, 1 А220 VU* 5 ± 5%
1 А 5
BPI5-1, 3 А 3 А 15
115Catalogue of Products
www.elpribor.ru
NEW DECISIONS FOR APCSAND TELEMECANICS
DIGITAL INPUT/OUTPUT MODULES TELEMETRY CONTROLLER
UNDERDEVELOPMENTIn 2017, it is expected the market approach of a new series of products from JSC «Elektropribor» specialized in the implementation of telemechanics function.
New solutions perfectly complement the range plant products and allow to create complex telemetry systems, remote signaling and remote control on the integrated technological basis in accordance with the most relevant requirements.
Digital I/O module is designed to collect information from sensors and control of meters with digital interfaces. The module is equipped with field interface EIA/RS-485. A number of digital input and output interfaces is optimized for setting telemetry of medium voltage switchgear cell.
A telemetry controller is intended for connection to digital input-output modules and measuring instruments through interfaces EIA/RS-485. The controller provides data collection from the connected meters and data submission via the information protocols through the communication interfaces, as well as receiving control commands and their transmission to the digital input-output modules.
Scope of telemetry system complex: automated systems of telemetry, scheduling, observation improvement systems, etc.
Power supply interface 220 VAC/VDC
Communication interface RS-485-Modbus, IEC 60870-5-101
Power supply interface 220
VAC/VDC
2 communication interfaces ETHERNET- IEC 60870-5-104, IEC 61850-8-1 (integration
into APCS and TM systems)
6 communication interfaces RS-485- Modbus, IEC 60870-5-101 (interrogation
of DI/DO meters and modules)Digital input interface 12 DI (24/220 VDC)
Digital output interface (internal relay)
TMC
DIOM
Cell controller (light)
Cell controller (IEC 104/61850)
Telemechanics module system
Input/output module
Input/output module
Panel meter
Panel meter
Ethernet(IEC 60870-5-104/
IEC 61850)
Remote signaling/remote control
Remote signaling/remote control Telemetry/Remote
signaling/Remote control
Tele
met
ry
Input/output module
Meters
EIA/RS-485(IEC 60870-5-101)
EIA/RS-485(IEC 60870-5-101)
EIA/RS-485(IEC 60870-5-101)
EIA/RS-485(IEC 60870-5-101)
EIA/RS-485(ModbusRTU,
IEC 60870-5-101)
IEC 60870-5-104IEC 61850
Telemechanics controller
3 Measuring converters
118 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Multifunctional measuring converters
E900EL, E849ELE series converters are intended
to measure and convert electrical parameters in 3-phase 3-wire and 3-phase 4-wire electrical AC mains into the unified output DC signals and sequence of digital signals for transmission through interfaces RS485, Ethernet (protocols Modbus RTU, Modbus TCP, IEC 60870-5-101, IEC 60870-5-104).
E series converters may be used for:
– control of main electrical parameters in 3-phase mains;
– technical metering of electric power.
Type Overall dimensions, mm, max Weight, kg, max.
E900EL, E849EL 161.6 х 105.2 х 62.2 0.7
Three-phase parameters DesignationMeasured parameters
E900EL E849EL
Effective phase voltage value UA, UB, UC + -
Average effective phase voltage value U + -
Effective line-to-line voltage value UAB, UBC, UCA + -
Average effective line-to-line voltage value Ul + -
Effective phase current value IA, IB,IC + -
Average effective phase current value I + -
Active load phase power PA, PB, PC + +
Total active power P + +
Reactive load phase power QA, QB, QC + +
Total reactive power Q + +
Full load phase power SA, SB, SC + +
Total gross reactive power S + +
Phase power factor cosφA, cosφB, cosφC + -
Total power factor cosφ + -
Frequency F + -
Active power WP + -
Reactive power WQ + -
Power quality parameters
Frequency deviation, Hz (-5...5 Hz) + -
ACF duration, s (0.02...60 s) + -
ACF depth, % (10...99 %) + -
Voltage interruption duration, s (0.02...60 s) + -
Temporary overvoltage duration, s (0.02...60 s) + -
119Catalogue of Products
www.elpribor.ru
Information display
LED indication (single indicators)
– supply voltage; – digital inputs condition; – data transmission through Wi-Fi; – phase sequence indicator;
– Interface RS485 operation;– relay output condition;– event indicator
LCD (by order) Colour; LCD dimension: 46.7х35.4 mm (2.2»)
Additional features Connection of Display panel MI120, MI80 via interface RS485, Ethernet
TelemetryInput signal
Current, A: Voltage, V:
Frequency, Hz:
1.0; 5.0; range 0...2.0 Irated 100, 380, 400; range 0...1.2 Urated 45...55
Measurement time 0.1 s
Time of setting output analogue signal, max 0.5 s
Basic error limitsby current and voltage: ± 0.2%; by power: ± 0.5 %; by frequency: ± 0.01 Hz; by analogue output: ± 0.5%
Galvanic isolation of input and output circuits, power circuits Yes
Short-term overloads by input signal with ratio (maximum)Ratio: 20; number of overloads: 2; duration of each overload, s: 0.5; interval between two overloads, s 0.5.
Input resistance: by current circuits, max.by voltage circuits, min.
0.02 Ω1 MΩ
Communication interfaces/Analogue output
RS485Quantity: 1,2; protocols: Modbus RTU, IEC 60870-5-101Data rate: 4800, 9600, 19200, 38400, 57600 baud.
Ethernet Quantity: 0, 1, 2; 100 BASE TX; protocols: Modbus TCP, IEC 60870-5-104
Wi-Fi Quantity: 0.1; standard IEEE 802.11
Analogue outputQuantity: 0,1,2,3; reprogrammed ranges: 0…5 mA, 4…20 mA, 0…20 mA, 0…2.5…5 mA, 4…12…20 mA, -5…0…+5 mA, 0...10...20 mA
Remote indicationDigital inputs Quantity: 8; “dry contact” type, voltage =24 V, current 10 mA
Distant controlRelay outputs Quantity: 0, 1, 2, 3 (switch on/off, interlocking); voltage ~250 V, =30 V, current 5 A
Supply voltage
Power supply– 24 VN (24+12/-6) VDC– 220 VU, universal (90...264 VAC, (50 ± 0.5) Hz or 130...370 VDC)– measuring circuit
Power consumption from power circuit, max. 7 VA
Meter reprogramming (setting)
Reprogramming– via program “Configuration Manager” (interface RS485, Ethernet);– via Web-interface (interface Ethernet, Wi-Fi);– with buttons on the front frame (if any)
Reprogramming parameters
– connection diagram (3- or 4-wire);– indices range (meters with rated currents of 1 A, 5 A and voltage of 100 V);– password setting;– indication update period: from 0.1 to 10 s;– decimal point position; settings for each electrical value (with discrete outputs of up to 3 control signals for commutation equipment);– interfaces RS485, Ethernet, Wi-Fi parameters;– output signal parameters; indication brightness;– parameters of protocol Modbus RTU, Modbus TCP, IEC 60870-5-101, IEC 60870-5-104 (via program “Configuration Manager», Web-interface);– calibration of input and output signals.
Operation ConditionsTemperature range (operating) minus 40°С to plus 70°С
Protection extent IP20 according to GOST 14254-96
Installation DIN-rail 35 mm
Wires section 2.5 mm2
Maximum input signal overload (duration) 150 % (2 hours)
Calibration interval 10 years
Guarantee period 24 months
Mean life, min 20 years
Mean time between failures 250000 hours
120 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Ordering examples
Order form
E a – b – c – d – e – f – g – h – i – j – k
а – transducer type depending on functional possibilities:849EL – power measuring transducer;900EL – multifunctional transducer;
b – rated voltage:100 V, 380 V, 400 V – line voltage;U/100 – voltage transformation factor (rated secondary winding voltage of 100 V);
c – rated current:1.0 А; 5.0 А – phase current;I/1; I/5 – current transformation factor(rated secondary winding current of 1 А and 5 А);
d – reference designation of supply voltage:24VN – DC supply voltage of (24+12/-6) V;220 VU – universal power: supply voltage of 90 to 264 VAC, 50 Hz or 130 to 370 VDC;from the measuring circuit within range 85 ...253 V;
e – reference designation for availability of interfacesRS485 and wireless network WiFi:1RS – availability of main interface RS485;1RSW – availability of main interface RS485 and wireless network WiFi;2RS – availability of main and additional interfaces RS485;
f – reference designation for availability of interfacesх – specified with the absence;1RE – availability of one interface Ethernet;2RE – availability of two interfaces Ethernet;
g – reference designation of 8 digital inputs:х – specified with the absence;DI – availability of 8 digital inputs;
h – reference designation of output signals:х – specified with the absence;01 – one digital output without analogue outputs,02 – two digital outputs without analogue outputs;03 – three digital outputs without analogue outputs;10(а) – one analogue output without digital outputs;11(a) – one analogue and one digital output;12(A) – one analogue and two digital outputs;13(a) – one analogue and three digital outputs;20(а,b) – two analogue outputs without digital ones;21(а,b) – two analogue and one digital output;22(а,b) – two analogue and two digital outputs;23(а,b) – two analogue and three digital outputs;30(а,b,c) – three analogue outputs without digital ones;31(а,b,c) – three analogue and one digital output;32(а,b,c) – three analogue and two digital outputs;33(а,b,c) – three analogue and three digital outputs;where а, b, c – reference designations of measurement ranges of output analogue signals(А = 0...5 mA; В = 4...20 mA; С = 0...20 mA;АР = 0…2.5…5 mA; ВР = 4…12…20 mA;СР = 0…10…20 mA; ЕР = -5…0…5 mA) (Example:(Example: (12(А); 21(В,В); 33(С,А,В); 30(С, В, С));
i – indication type:х – specified with the absence;LCD – colour liquid-crystalline display, touch sensitive.
j – operational design:х – for general industrial meters;ОМ2 - meters for marine application;А – for operation at NPP (safety class 4);
k – custom design (for E849EL transducer only):P – active power measurement;Q – reactive power measurement;PQ – active and reactive power measurement;– with the absence of custom design parameter is not specified.
E900EL – 400V – 5А– 220VU –1RSW – 2RE – DI – 33(А,В,А) – х – х TU 25-7504.232-2016For multifunctional transducer with the following characteristics: rated voltage of 400 V, rated current of 5 A, supply voltage of 90 to 264 VAC, 50 Hz or 130 to 370 VDC, 50 Hz, main interface RS485, wireless network WI-FI, availability of two interfaces Ethernet, digital inputs, three analogue outputs 0…5 mA, 4…20 mA, 0...5 mA, three digital outputs.
E849EL – 100V – 1А– 220VU – 1RS – 1RE – DI – 12(А) – х – ОМ2 – РQ TU 25-7504.232-2016For power transducer with the following characteristics: rated voltage of 100 V, rated current of 1 A, supply voltage of 90 to 264 VAC, 50 Hz or 130 to 370 VDC, 50 Hz, main interface RS485, availability of Ethernet, digital inputs, analogue output 0…5 mA, two digital outputs, operation on marine vessels, measurement of active and reactive power.
E849EL – 10000/100 – 600/5 – 24VN – 2RS – х – х – 01 – LCD – x Р TU 25-7504.232-2016For power transducer with the following characteristics: voltage transformation factor Kvt = 10000/100, current transformation factor Kct = 600/5, supply voltage (24+12/-6) VDC, main and additional interfaces RS485, one digital output, LCD, measurement of active power.
121Catalogue of Products
www.elpribor.ru
Overall and mounting dimensions
Connection diagram
Notes
1. Supply voltage depends on a transducer design.2. Availability and number of analogue outputs (contacts 11-16) depend on a transducer design.3. Availability of digital inputs (contacts 26-34) depends on a transducer design.4. Availability and number of digital outputs (contacts 35-40) depend on a transducer design.5. Availability of additional interface RS485 (contacts 41 - 43) depends on a transducer design.
Digital inputs Analogue outputs
Additionalinterface
Digital outputs
Port 1
Main RS485
Port 2
Power supply
Power supply source
122 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Direct current and direct voltage measuring converters
E856EL
Direct current and direct voltage measuring converters E856EL are intended for current and voltage measurement in one-phase DC circuits. The converters are used to control current and voltage of electrical systems and installations, for integrated automation of electric power industry facilities, APCS of energy-consuming facilities of different industry sectors, on marine vessels.
The converters may be used for operation in the field of defense and safety.
The possibility of data exchange through interface RS485 allows using The converters for digital data transmission to APCS.
The converters may have a design without interface RS485.
Type Overall dimensions, mm, max Weight, kg, max.
E856ELwith RS485 70 х 85.5 х 89 0.4
without RS485 70 х 86 х 80 0.5
Input signalOutput signal Load resistance,
max.
output 1 output 2 For the analogue output:2,5 kΩ (0...5 mA,0...2,5...5 mA);
2 kΩ (-5...0...5 mA);0,5 kΩ (0...20 mA,
4...20 mA, 4...12...20mA,0...10...20 mA)
0...5mA, 4...20mA,0...20mA, -5...0...5mA
0...75mV,-75...0...75mV, 0...60V,
0...100V, 0...150V,0...250V
0...5mA, 0...20mA,4...20mA, 0...2,5...5mA,
-5...0...5mA, 4...12...20mA,0...10...20mA
0...5mA, 0...20mA,4...20mA, 0...2,5...5mA,
4...12...20mA,0...10...20mA,-5...0...5mA
0...500V, 0...1000V no
Basic error limits ±0,5%
A number of output signals 1 or 2
Temperature range (operating) -40 °С... +50 °С
Power supply
– 12 VN (12+6/-3) VDC– 24 VN (24+12/-6) VDC– 220 VU, 85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC– 230 V, 85...253 VAC, (50 ± 0.5) Hz
Galvanic isolation of input and output circuits, power circuits
Yes
Protection extent IP50
Interface
RS485 (МodbusRTU), quantity: up to 2– basic for data transmission– additional for data transmission or connection of the display (Т44, Т54, Т74), Display panel (MI120, MI80)
Data rate 4800, 9600, 19200, 38400 baud.
Maximum input signal overload 120%, duration of 2 hours
Short-term overloads by input signal with ratio2 (10 s); 7 (15 s); 10 (3 s); 20 (0.5 s) (from the rated current value)1.5 (0.5 s) (from the rated voltage value)
Time of setting output analogue signal, max 0.5 s
Power consumption from power circuit, max. 6.0 V•А
Power consumptionby voltage circuits, max:by current circuits, max:
1 W0.01 W
Installation DIN-rail 35 mm or directly on the panel
Calibration interval 4 years
Guarantee period 2 years
Mean life, min 15 years
Mean time between failures, min 100000 hours
Note: power supply and input signals are connected by terminal connectors “for screw” for wires of up to 4.0 mm2 in cross-section.
Design with RS485
Design without RS485
123Catalogue of Products
www.elpribor.ru
Ordering examplesOrder formE856EL – -75…0…75 mV – 24VN – АР – В – 2RS TU 25-7504.216-2011E856EL transducer with the following characteristics: input signal measurement range -75...75 mV, supply voltage of (24+12/-6) VDC, measurement range analogue output signal of 0…2.5…5 mA, measurement range additional analogue output signal of 4...20 mA, two interfaces RS485.
E856EL – а –b – с – d – e – f
a – input signal measurement ranges:0...5 mA, 4...20 mA, 0...20 mA, -5...0...+5 mA0...75 mV; -75...0...75 mV;0...60 V; 0...100 V; 0...150 V; 0...250 V; 0...500 V;0…1000 V
b – supply voltage:12 VN (12+6/-3) VDC24 VN (24+12/-6) VDC220 VU from 85...253 VAC, (50 ± 0.5) Hz or 120...265 VDC230 V from 85...253 VAC, (50 ± 0.5) Hz
c – measurement range analogue output signal:А = 0...5 mA;В = 4...20 mA;С = 0...20 mA;АР = 0...2.5...5 mA;ВР = 4...12...20 mA;СР = 0...10...20 mA;ЕР = -5…0…+5 mA;х with the absence
d – measurement range additional analogue output signal:А = 0...5 mA;В = 4...20 mA;С = 0...20 mA;АР = 0...2.5...5 mA;ВР = 4...12...20 mA;СР = 0...10...20 mA;EP = -5...0...+5 mAх with the absence
e – interface:1 RS – one RS485 (main)2RS – two RS485 (main and additional)х – with the parameter absence
f – custom design:А – operation at NPP(safety class – 4);ОМ2 – meters for marine application.With the absence of custom design parameter is not specified.
Connection diagrams
Powersupply
E856EL (w/ RS485)
E856EL (w/o RS485)
Input
Output 1 Output 2
Inputsignal
Upwr
Analogue outputs
E856EL
Analogueoutputs
1 PortRS485
2 PortRS485
E856EL
Powersupply
Inputsignal
124 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
E856EL (w/ RS485)
E856EL (w/o RS485)
2 holes
2 holes
125Catalogue of Products
www.elpribor.ru
E1856EL
Ordering examples
Order form
Direct current and direct voltage measuring converters E1856EL are intended for current and voltage measurement in one-phase DC circuits.
The converters may be used to control current and voltage of electrical systems and installations, as well as for automation of different electric power industry facilities, fields of defense, safety and industry.
E1856EL – 0…20mA – 220VU – СР – 01 TU 25-7504.226-2014For the transducer with the following characteristics: transducer type E1856EL, measurement range input signal of 0...20 mA, supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC, measurement range analogue output signal of 0…10…20 mA, digital output.
Overall and mounting dimensions
E1856EL – а –b – с – d – f
a – input signal measurement ranges:0...5 mA, 4...20 mA, 0...20 mA, -5...0...5 mA,0...75 mV, -75...0...75 mV, 0...60 V, 0...100 V,0...150 V, 0...250 V, 0...500 V
b – supply voltage:220 VU – universal power: supply voltage of 85 to 253 VAC, 50 Hz or 120 to 265 VDC;230 V – supply voltage of 85...253 VAC, 50 Hz;12 VN – (12+6/-3) VDC;24 VN – (24+12/-6) VDC
c – measurement range analogue output signal:А = 0...5 mA; В = 4...20 mA;С = 0...20 mA; АР = 0…2.5…5 mA; ВР = 4…12…20 mA;СР = 0…10…20 mA; ЕР = -5…0…+5 mA; x – with the absence
d – digital output availability:х – no output01 – one digital output
f – custom design:А – operation at NPP(safety class – 4).With the absence of custom design parameter is not specified.
Connection diagrams
Type Overall dimensions, mm, max Weight, kg, max.
E1856EL 24 х 111 х 116 0.3
Input signal0...5 mA, 4...20 mA, 0…20 mA, -5...0...5 mA0...75 mV; -75...0...75 mV; 0...60 V; 0...100 V; 0...150 V; 0...250 V; 0...500 V
Basic error limits ±0,5%
Temperature range (operating) -40 °С... +50 °С
Protection extent IP50
Interface RS485 (Мodbus RTU) – main, for data transmission
Data rate 4800, 9600, 19200, 38400 bit/s.
Parameters setting (reprogramming) through the interface
– digital output;– interface RS485 (Modbus RTU) parameters;– analogue output signal parameters
Analogue outputQuantity: 0, 1Ranges: 0...5 mA; 0...20 mA; 4…20 mA; 0...2.5...5 mA; 4…12…20 mA; 0…10…20 mA; -5…0…5 mA
Digital outputDC voltage: 300 V; 100 mA AC voltage: 200 V; 100 mA
Maximum input signal overload 150%, duration of 2 hours
Time of setting output analogue signal, max 0.5 s
Installation DIN-rail of 35 mm
Power supply
220 VU – universal power: supply voltage of 85 to 253 VAC,50 Hz or 120 to 265 VDC;230 V – supply voltage of 85...253 VAC 50 Hz;12 VN – (12+6/-3) VDC;24 VN – (24+12/-6) VDC
Power consumption from power circuit, max. 6.0 V•А
Power consumptionby voltage circuits, max:by current circuits, max:
0.5 W0.01 W
Calibration interval 8 years
Guarantee period 2 years
Mean life 20 years
Mean time between failures 200000 hours
Inputsignal
Analogueoutput
Power supply
Digitaloutput
OutputInput
E1856EL
126 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Alternating current and alternating voltage measuring converters
E854EL
The converters are intended for line conversion of AC input signal and voltage with 50 Hz into one or two unified galvanically isolated output DC signals.
The converters are used to control current and voltage of electrical systems, installations and for automation of different facilities of electric power industry, on marine vessels.
Type Overall dimensions, mm, max Weight, kg, max.
E854ELwith RS485 70 х 85.5 х 89
0.4without RS485 70 х 85.5 х 79
Input signalOutput signal measurement range, mA
Fiducial value Load resistance, max., Ω
alternating current, A
AC voltage, V output 1 output 2
-
0...1250...25075...125150...2500...1000...4000...500
0...5 0...5 5 0...2500
4...200...20
4...200...20
20 0...500
0...0,50...10...2,50...5
-
0...5 0...5 5 0...2500
4...200...20
4...200...20
20 0...500
Basic error limits ±0,5%
A number of output signals 1 or 2
Temperature range (operating) -40 °С... +50 °С
Power supply voltage
– 12 VN (12+6/-3) VDC– 24 VN (24+12/-6) VDC– 220 VU, 85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC– 230 V from 85...253 VAC, (50 ± 0.5) Hz
Protection extent IP50
Interface
RS485 (МodbusRTU), quantity: up to 2– basic for data transmission– additional for data transmission or connection of the display (Т44, Т54, Т74), Display panel (MI120, MI80)
Interface exchange rate 4800, 9600, 19200, 38400 baud.
Maximum input signal overload 120%, duration of 2 hours
Short-term overloads by input signal with ratio2 (10 s); 7 (15 s); 10 (3 s); 20 (0.5 s) (from the rated current value)1.5 (0.5 s) (from the rated voltage value)
Time of setting output analogue signal, max 0.5 s
Power consumption from power circuit, max. 6.0 V•А
Power consumptionby voltage circuits, max: by current circuits, max:
1 W0.01 W
Installation DIN-rail 35 mm or directly on the panel
Calibration interval 4 years
Guarantee period 2 years
Mean life, min 15 years
Mean time between failures, min 100000 hours
Note: power supply and input signals are connected by terminal connectors “for screw” for wires of up to 4.0 mm2 in cross-section.
Design with RS485
Design without RS485
127Catalogue of Products
www.elpribor.ru
Ordering examplesOrder form
E854EL – 0…250 V – 220VU – Gr – х – 1RS – А TU 25-7504.216-2011E854EL transducer, measurement range input signal of 0...250 V, supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC, measurement range analogue output signal of 0…20 mA, one interface RS485, operation at NPP.
E854EL – -75…225 V – 230 V – А – В – 2RS TU 25-7504.216-2011E854EL transducer, input signal measurement range 75...125 V, supply voltage of 85...253 VAC, 50 Hz, measurement range analogue output signal of 0…5 mA, measurement range additional analogue output signal of 4...20 mA, two interfaces RS485.
E854EL – а –b – с – d – e – f
a – input signal measurement ranges:0...0.5 A; 0...1 A; 0...2.5 A; 0...5 A;0...100 V; 0...125 V; 0...250 V; 0...400 V;0...500 V; 75...125 V; 150...250 V
b – supply voltage:12 VN (12+6/-3) VDC24 VN (24+12/-6) VDC220 VU from 85...253 VAC, (50 ± 0.5) Hz or 120...265 VDC230 V from 85...253 VAC, (50 ± 0.5) Hz
c – measurement range analogue output signal:А = 0...5 mA; В = 4...20 mA; С = 0...20 mA;х – with the absence
d – measurement range additional analogue output signal:А = 0...5 mA; В = 4...20 mA; С = 0...20 mA;х with the absence
e – interface:1 RS – one RS485 (main)2RS – two RS485 (main and additional)х – with the parameter absence
f – custom design:А – operation at NPP (safety class 4)ОМ2 – meters for marine application.With the absence of custom design parameter is not specified.
Connection diagram
Inputsignal
Analogueoutputs
1 PortRS485
2 PortRS485
E854EL
Powersupply
Inputsignal
E854EL (w/ RS485)
E854EL (w/o RS485)
Powersupply
E854EL
Analogueoutputs
128 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Overall and mounting dimensions
E854EL (w/ RS485)
E854EL (w/o RS485)
2 holes
2 holes
129Catalogue of Products
www.elpribor.ru
E1854EL
Ordering example
Order form
Alternating current and alternating voltage measuring converters E1854EL are intended for current and voltage measurement in one-phase AC circuits.
The converters may be used to control current and voltage of electrical systems and installations, as well as for automation of different electric power industry facilities, fields of defense, safety and industry.
E1854EL – 0…2.5 A – 12 VN – В – 01 – А TU 25-7504.226-2014For the transducer with the following characteristics: E1854EL transducer type, measurement range input signal of 0... 2.5 A, supply voltage of (12+6/-3) VDC, measurement range output signal of 4…20 mA, digital output, for operation at NPP (safety class 4).
Overall and mounting dimensions
E1854EL – а –b – с – d – f
a – input signal measurement ranges:0...0.5 A, 0...1 A, 0...2.5 A, 0...5 A,0...125 V, 0...250 V, 0...500 V, 75...125 V,150...250 V
b – supply voltage:220VU – universal power:supply voltage of 85...253 VAC, 50 Hz or 120 ...265 VDC;230 V – supply voltage of 85...253 VAC, 50 Hz;12 VN – (12+6/-3) VDC;24 VN – (24+12/-6) VDC
c – measurement range analogue output signal:А = 0...5 mA; В = 4...20 mA; С = 0...20 mA;х with the absence
d – digital output availability:х – no output01 – one digital output
f – custom design:А – operation at NPP(safety class – 4)With the absence of custom design.
Connection diagram
Type Overall dimensions, mm, max Weight, kg, max.
E1854EL 24 х 111 х 116 0.3
Input signal0...0.5 A, 0...1 A, 0...2.5 A, 0...5 A,0...125 V, 0...250 V, 0...500 V, 75...125 V, 150...250 V
Basic error limits ±0,5%
Temperature range (operating) -40 °С... +50 °С
Protection extent IP50
Installation DIN-rail of 35 mm
Interface RS485 (Мodbus RTU) – main, for data transmission
Data rate 4800, 9600, 19200, 38400 bit/s.
Parameters setting (reprogramming) through the interface
– digital output– interface RS485 (Modbus RTU) parameters– analogue output signal parameters
Analogue output (Accuracy class 0,5)Quantity: 0, 1Ranges: 0...5 mA; 0…20 mA; 4...20 mA
Digital outputDC voltage: 300 V; 100 mA AC voltage: 200 V; 100 mA
Maximum input signal overload 150%, duration of 2 hours
Time of setting output analogue signal, max 0.5 s
Power supply
– 220 VU, 85...253 VAC,– 50 Hz or 120...265 VDC– 230 V, 85...253 VAC, 50 Hz– 12 VN (12+6/-3) VDC– 24 VN (24+12/-6) VDC
Power consumption from power circuit, max. 6.0 V•А
Calibration interval 8 years
Guarantee period 2 years
Mean life 20 years
Mean time between failures 200000 hours
Inputsignal
Analogueoutput
Power supply
Digitaloutput
OutputInput
E1854EL
130 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
EP34S
Ordering example
EP34S transducers are intended for line conversion of alternating current and alternating voltage with 50 Hz in electrical circuits with rated voltage of up to 660 V into the unified output DC signal. The converters may be used to control current and voltage of electrical systems and installations, as well as for automation of different electric power industry facilities, and in other sectors of the industry.
The converters are single-channel articles without galvanic connection between input and output circuits. The converters are mounted on the standard DIN-rail of 35 mm in width or directly on the panel.
EP34S 0-0.5А 0-5mA TU-25-7504.189-2005For EP34S transducer with input signal range 0...0.5 A with output current range 0...5 mA.
Type Overall dimensions, mm, max Weight, kg, max.
EP34S 70 х 85,5 х 79 0.4
Input signal range Output current range, mA Load resistance, Ω Power supply
alternating current, A
0...0,5; 0...1;0...2,5; 0...5
0...5 0...2500
from the measured circuit0...20 0...500
0...25; 0...50; 0...100 0...20 0...500
Basic error limit ±0,5 %
Temperature range (operating) -30 °С...+50 °С
Number of analogue outputs 1
Galvanic isolation of input and output circuits, power circuits
Yes
Protection extent IP00
Installation DIN-rail 35 mm or directly on the panel
Input signal0...0.5 A; 0...1 A; 0...2.5 A; 0...5 A; 0...25 A; 0...50 A; 0...100 A
Analogue output (Accuracy class – 0,5)quantity:
range:10...5 mA, 0…20 mA
Maximum input signal overload 120%, duration of 2 hours
Short-term overloads by input signal with ratio (s)2 (10 s); 7 (15 s); 10 (3 s); 20 (0.5 s) (from the rated current value)1.5 (0.5 s) (from the rated voltage value)
Time of setting output analogue signal, max 0.5 s
Power supply Measured circuit
Power consumption from power circuit, max. 4.0 V•A
Power consumption from the input signal circuit, max.:
1.2 V•A
Calibration interval 1 year (with 8-hours daily operating time)
Guarantee period 4 years
Mean life 10 years
Mean time between failures 20,000
Note: screw clamps for connection of outer circuits provide contact with the live wires. Each clamp provides connection of copper or aluminium wires with cross-section of up to 2.5 mm2.
131Catalogue of Products
www.elpribor.ru
Connection diagrams
Outputanalogue
signal
Overall and mounting dimensions
Outputanalogue
signal
OutputOutput
Input
Inputsignal source
Through bus
EP34S
EP34S
2 holes
2 holes
EP34S with input signal measurement range 0...0.5 A; 0...1 A; 0...2.5 A; 0...5 A
EP34S with input signal measurement range 0...25 A; 0...50 A; 0...100 A
132 Measuring transducers
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Frequency measuring converters
E1858EL
Ordering example
Order form
E1858EL converters are intended to measure AC frequency based on the analogue-digital conversion of input signals.
E1858EL – 45…65 Hz – 230 V – А – 01 TU 25-7504.226-2014For the transducer with the following characteristics: transducer type E1858EL, measurement range input signal of 45...65 Hz, supply voltage of 85...253 VAC, 50 Hz, change range output signal of 0…5 mA, digital output.
Overall and mounting dimensions
E1858EL – а –b – с – d – f
a – input signal measurement ranges:45...65 Hz, 300...500 Hz
b – supply voltage:220VU – universal power:supply voltage of 85...253 VAC, 50 Hz or 120 ...265 VDC;230 V – supply voltage of 85...253 VAC, 50 Hz;12 VN – (12+6/-3) VDC;24 VN – (24+12/-6) VDC
c – measurement range analogue output signal:А = 0...5 mA; В = 4...20 mA;С = 0…20 mA; АР = 0…2.5…5 mA;ВР = 4…12…20 mA; СР = 0…10…20 mA; ЕР = -5…0…+5 mA; х – with the absence
d – digital output availability:х – no output01 – one digital output
f – custom design:А – operation at NPP(safety class – 4)With the absence of custom design parameter is not specified.
Connection diagram
Type Overall dimensions, mm, max Weight, kg, max.
E1858EL 24 х 111 х 116 0.3
Input signal 45...65 Hz, 300...500 Hz
Rated input voltage 50 V...500 V
Basic error limits ±0,5%
Temperature range (operating) -40 °С... +50 °С
Protection extent IP50
Installation DIN-rail of 35 mm
Interface RS485 (Мodbus RTU) – main, for data transmission
Data rate 4800, 9600, 19200, 38400 bit/s.
Parameters setting (reprogramming) through the interface
– digital output– interface RS485 (Modbus RTU) parameters– analogue output signal parameters
Analogue output (Accuracy class 0,5)Quantity: 0, 1Ranges: 0...5 mA; 0...20 mA; 4…20 mA; 0...2.5...5 mA; 4…12…20 mA; 0…10…20 mA; -5…0…5 mA
Digital outputDC voltage: 300 V; 100 mAAC voltage: 200 V; 100 mA
Maximum input signal overload 150%, duration for 2 hours
Time of setting output analogue signal, max 0.5 s
Power supply
– 220 VU, 85...253 VAC,– 50 Hz or 120...265 VDC– 230 V, 85...253 VAC, 50 Hz– 12 VN (12+6/-3) VDC– 24 VN (24+12/-6) VDC
Power consumption from power circuit, max. 6.0 V•А
Calibration interval 8 years
Guarantee period 2 years
Mean life 20 years
Mean time between failures 200000
Inputsignal
Analogueoutput
Power supply
Digitaloutput
OutputInput
E1858EL
4 AUXILIARYCOMPONENTS
134 Auxiliary components
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Multiplying resistor
R4201
Multiplying resistor R4201 is interchangeable intended for expansion of voltage measurement ranges of electrical meters (voltmeters) in DC circuits.
Overall and mounting dimensions
Measuring range:Accuracy class Operation conditions
rated current rated voltage
1 or 5 mA 1000 V
0,5
Temperature -60...+60 °С, relative humidity 98 % at temperature +40 °С.Impact resistance:acceleration 150 m/s2,frequency 10...50 impacts per min.,number of impacts – 2000.Vibration strength:acceleration 30 m/s2, frequency 10...120 Hz.Vibration strength:acceleration 10 m/s2,frequency 20 Hz.
5 mA 1500 V
1 mA 2500 V
5 mA 3000 V
1 mA 4000 V
135Catalogue of Products
www.elpribor.ru
SHUNTS
75ShIS, 75ShISV,75ShISV.1, 75ShISV.2,
60ShISV.2
Shunts 75ShIS, 75ShISV, 75ShISV.2, 60ShISV.2 are intended for expansion of measurement ranges displaying and recording the DC meters (ammeters).
Shunts 75ShISV.1 are intended for expansion of measurement ranges of panel digital DC meters.
Measuring rangeAccuracy class Operation Conditions
rated current rated voltage
75ShISА – 20; 30; 50; 75; 100; 150;200; 300; 500; 3000; 4000;5000; 6000; 7500; 10000;15000
75 mV 0.5
Temperature -40...+50 °С, relative humidity 98 % at temperature +40 °С.Impact resistance:acceleration 150 m/s2,frequency 10...50 impacts per min.,number of impacts – 2000.Vibration strength:acceleration 30 m/s2,frequency 10...120 Hz
75ShISVА – 20; 25; 30; 40; 50; 60; 75; 100; 150; 200; 250; 300; 400; 500; 600; 750; 1000; 1500; 2000; 2500
75 mV 0.5
75ShISV.2А – 1; 1.5; 2; 2.5; 3; 4; 5; 6;7.5; 10; 15
75 mV 0.5
60ShISV.2А – 1; 1.5; 2; 2.5; 3; 4; 5; 6;7.5; 10; 15
60 mV 0.5
75ShISV.1
А – 10; 20; 100; 200; 1000;2000
75 mV 0.2Temperature 0...+50 °С, relative humidity 80 % at temperature +25 °С.The shunts are vibration and shock resistan
Cutout
Overall and mounting dimensions
75ShISV, 75ShISV.1, 75ShISV.2, 60ShISV.2, 75ShIS (up to 50 A inclusively)
136 Auxiliary components
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Figure 1
Figure 3
Figure 5 Figure 6
Figure 4
Figure 2
137Catalogue of Products
www.elpribor.ru
Figure 7 Figure 8
Figure 9
Note:
A number of resistive elements of rods and plates may differ from the those which are specified in Figures.
138 Auxiliary components
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Shunt typeRated shunt
current, AFigure
Dimensions, mmWeight, kg
L A B h C H N Dxl
75 ShISV
60; 751
95 75 16 6-
30
-
М6х20 0.1
100
105 85
20 6
35М8х25
0.2150
2
16
812
20020
250; 300 18 М10х30
400
145 9035
10
20 55М16х45
1.0500
600
750
501000165 110
3065
1.2
1500 50
М16х50
1.5
20003 195 140
8015 50 80 50
2.2
2500 100 2.5
Shunt typeRated shunt
current, AFigure
Dimensions, mmWeight, kg
L A N B h C H Dxl
75ShISV.1
100 1110 90
-
20 6 -35
М8х25 0.2
2002
35 8 18 М10х30 0.7
1000 165 110 50 1050
65 М16х45 1.3
2000 3 195 140 50 80 15 80 М16х50 2.2
Shunt type Rated shunt current, A Figure Dxl Weight, kg
75ShIS
3000 5 М16х60 4.4
4000 6
М18х80
7.0
50007
11.0
6000 11.0
7500 8 13.00
Shunt type
Rated shunt
current, A
FigureDimensions, mm
Weight, kg A1 A2 B1 B2 B3 C1 C2 E h Dxl
75ShIS10000
9 200 75206 25 52
30 20 150 170 М20х8022.00
15000 310 25 52 33.00
Shunt typeRated shunt
current, AFigure
Dimensions, mm
L A B C h H Dxl Weight, kg
75 ShIS
75
4
121 107
20 28 4
37 М6х20 0.12
100 118 98
42 М8х200.16
150 131 111
200 118 98 0.15
300 142 120 3433 5
53 М10х30 0.4
500 160 130 52 65 М16х40 0.82
139Catalogue of Products
www.elpribor.ru
Current transformers
TOP 0.66
Current transformers TOP 0.66 are intended to transmit signal of measuring information to meters (ammeters, wattmeters, phase meters, counters) in AC installations of 50 Hz with rated voltage of up to 0.66 kV, inclusively. As well as they are used in the measuring diagrams of low-voltage meters of building and structures, in power transmission and distribution diagrams including inside other articles and they are intended for revenue metering
The transformers are provided with two contacts of secondary winding, transparent cover protecting secondary winding clamps and data sheet. There is the possibility to set seals excluding the access to the secondary winding clamps and data sheet after mounting.
Example for ordering device with an aluminium bus for rated voltage of 0.66 kV, accuracy class 0.5, rated secondary load of 5 VA, for rated primary current of 800 A, rated secondary current of 5 A, climatic design U, category 3: TOP 0.66А-0.5-5.0-800/5 UЗ, TU 25-7504.178-2004.
Example for ordering device with a copper busfor rated voltage of 0.66 kV, accuracy class 0.5, rated secondary load of 5 VA, for rated primary current of 800 A, rated secondary current of 5 A, climatic design U, category 3: TOP 0.66М-0.5-5.0-800/5 U3, TU 25-7504.178-2004.
Example for ordering device with no busfor rated voltage of 0.66 kV, accuracy class 0.5, rated secondary load of 5 VA, for rated primary current of 800 A, rated secondary current of 5 A, climatic design U, category 3: TOP 0.66B-0.5-5.0-800/5 UЗ, TU 25-7504.178-2004.
Overall and mounting dimensions
TOP 0.66 (accuracy class 0.5; 0.5S; 1.0)Magnet core type – electrotechnical steelbus type – copper or aluminium
rated primary current rated secondary current, A
rated secondary load, V•A operation conditions
А – 1; 5; 10; 15; 20; 30; 40; 50;75; 80; 100; 150; 200; 300; 400; 500; 600; 750; 800; 1000; 1200; 1500; 2000
1; 5
5 (for accuracy class 0.5; 0.5S)10 (for accuracy class 1.0)
Temperature -45...+40 °С, relative humidity 98 % at temperature +25 °С (U3);temperature -10...+50 °С, relative humidity 98 % at temperature 35 °С (Т3);rated frequency 50 Hz
4 holes
Bus for currents of 1000-2000 А
140 Auxiliary components
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Rated primary
current, АА B C D E F
GH K d1 Opening size for
buses installationAI Cu
1-200 77 93 55 127 103 25 - 3 73
-
Ø 9-2 holes -
300-400 72 88
46
125 95 30 5 4 55 Ø 11-2 holes 5.5х30.5
500-800 105 121 150 115 50 8 5 60 Ø 14-2 holes 9х51
1000-1200150 170 182 132
8010
670
40 Ø 14-4 holes 20х82
1500-2000 100 8 60 Ø 14-4 holes 20х82
141Catalogue of Products
www.elpribor.ru
Adaptors and plugs
Protective cap KZ-4 is intended to protect against accidental contact with current-carrying rods when operating pointer DC and AC meters of up to 750 V, up to 1000 Hz.
The optimal decision simplifying selection of meters equivalents for discontinued articles with front panel dimensions of 160х160, 144х144 mm. Plastic adaptors allow installation of pointer and digital meters with 120х120 mm front panel in the mounting places of meters with the larger dimensions without additional panel modification.
A plug may be set both in panel holes, and in adaptors. Thus, having ordered 160х160 adaptor and plug, it is possible to close a panel hole remained after removal of other meter.
Type
Set designation for the order (including adaptor and/or plug, fastening, rails)
Adaptor/plug dimensions, mm
Internal hole in the adaptor, mm
Panel cutouts according to GOST 5944-91
Dimen-sions, mm
Permis- sible deviation, mm
1 Plug 120 (w/o adaptor) 5PCh.000.018 120х120 - 112х112 +0.9
2Adaptor 144 –› 120 (w/o plug)
5PCh.000.017-01 150х150 112х112 138х138 +1.0
3Plug 144 –› 120 (adaptor + plug)
5PCh.000.017-03 150х150 - 138х138 +1.0
4Adaptor 160 –› 120 (w/o plug)
5PCh.000.017 160х160 112х112142х142152х152155х155
+1.0+1.0+1.0
5Plug 160 –› 120 (adaptor + plug)
5PCh.000.017-02 160х160 -142х142152х152155х155
+1.0+1.0+1.0
6Adaptor 120 –› 96 (w/o plug)
5PCh.000.017-04 120х120 92х92 112х112 +0.9
Main characteristicsElectrical strength, kV 2.0
Resistance to temperature change from minus 5 to plus 60°C
Weight of protective caps (pair), kg, max. 0.01
Guaranteed storage life 12 months since the manufacture
Guarantee period 24 months
Mean life 12 years
Adaptor
Plug
Protective caps
142 Auxiliary components
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
Sets of case parts
Sets of case parts (case, cover, front panel) with the standard and reduced case depth, made of copolymer ABC, black (solid and light).
It is possible to modify a rear cover for various versions of connectors according to the Customer’s sketch.
Versions HхН1, mm L, mm L1, mm Weight, max., kg
Set 1
120х120
148 121.5 0.25
103 75.6 0.2
Set 2148 121.5 0.35
103 75.6 0.3
Set 196х96 103 75.6 0.16
Set 2
Set 172х72 103 75.6 0.12
Set 2
Set 196х48 148 121.5 0.13
Set 2
D – fastening version:1 – metal bracket 8PCh.120.283 with pin 8PCh.906.031(5PCh.012.000)2 – plastic bracket 8PCh.120.284 with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001)3 – plastic clamp 8PCh.140.3474 – plastic bracket 8PCh.120.284-01 (AF-312С, low-combustible) with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001-01)5 – plastic clamp 8PCh.140.347-01 (AF-312С, low-combustible)
KDA – type of case parts (by the Overall dimension, mm):KD120х120
B – front panel design:1 – front panel 8PCh.069.023 (ABS-2020)2 – front panel 8PCh.069.023-01 (AF-312С, low-combustible)
C – case parts design:1 – case 8PCh.005.546, length of 120 mm (ABS-2020)2 – case 8PCh.005.539, length of 74.1 mm (ABS-2020)3 – case 8PCh.005.546-01, length of 120 mm (AF-312С, low-combustible)4 – case 8PCh.005.539-01, length of 74.1 mm (AF-312С, low-combustible)
Form for ordering case parts for 120 х 120 mm meters
KDA.B.С– D
1 – panel design;2 – cover design;3 – case design;4 – front panel design.
143Catalogue of Products
www.elpribor.ru
Example for recording sets of case parts
KD96х48.1.1-3, whereparameter a KD96х48; parameter b design 1; parameter c design 1; parameter d design 3.
Form for ordering case parts for 96 х 96 mm meters
KDA.B.С– DKDA – type of case parts (by the Overall dimension, mm):KD96х96
B – front panel design:1 – front panel 8PCh.069.006 (ABS-2020)2 – front panel 8PCh.069.006-01 (AF-312С, low-combustible)
C – case parts design:1 – case 8PCh.005.538, length of 74.1 mm (ABS-2020)2 – case 8PCh.005.538-01, length of 74.1 mm(AF-312С, low-combustible)
D – fastening version:1 – metal bracket 8PCh.120.283 with pin 8PCh.906.031(5PCh.012.000)2 – plastic bracket 8PCh.120.284 with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001)3 – plastic clamp 8PCh.140.3474 – plastic bracket 8PCh.120.284-01 (AF-312С, low-combustible) with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001-01)5 – plastic clamp 8PCh.140.347-01 (AF-312С, low-combustible)
D – fastening version:1 – metal bracket 8PCh.120.283 with pin 8PCh.906.031(5PCh.012.000)2 – plastic bracket 8PCh.120.284 with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001)3 – plastic clamp 8PCh.140.3474 – plastic bracket 8PCh.120.284-01 (AF-312С, low-combustible) with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001-01)5 – plastic clamp 8PCh.140.347-01 (AF-312С, low-combustible)
D – fastening version:1 – metal bracket 8PCh.120.283 with pin 8PCh.906.031(5PCh.012.000)2 – plastic bracket 8PCh.120.284 with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001)3 – plastic clamp 8PCh.140.3474 – plastic bracket 8PCh.120.284-01 (AF-312С, low-combustible) with pin 8PCh.906.031 and nut 8PCh.940.403 (5PCh.012.001-01)5 – plastic clamp 8PCh.140.347-01 (AF-312С, low-combustible)
KDA – type of case parts (by the Overall dimension, mm):KD96х48
B – front panel design:1 – front panel 8PCh.069.010 (ABS-2020)2 – front panel 8PCh.069.010-01 (AF-312С, low-combustible)
C – case parts design:1 – case 8PCh.005.560, length of 120 mm (ABS-2020)2 – case 8PCh.005.560-01, length of 120 mm (AF-312С, low-combustible)
KDA – type of case parts (by the Overall dimension, mm):KD72х72
B – front panel design:1 – front panel 8PCh.069.010 (ABS-2020)2 – front panel 8PCh.069.010-01 (AF-312С, low-combustible)
C – case parts design:1 – case 8PCh.005.560, length of 74.1 mm (ABS-2020)2 – case 8PCh.005.560-01, length of 74.1 mm (AF-312С, low-combustible)
Form for ordering case parts for 72 х 72 mm meters:
Form for ordering case parts for 96 х 48 mm meters
KDA.B.С– D
KDA.B.С– D
144 Auxiliary components
ELECTROPRIBORJ O I N T S T O C K C O M P A N Y
INFORMATION ON REPLACEABLE EQUIVALENTS OF JSC “ELECTROPRIBOR”, CHEBOKSARY
Type Unit of measu- rement
JSC “Electropribor”
meter typeМ1001, EА2231, EV2231, EV0202 (mA, A, kA, V, kV ) М42301
М1360, EV2231, EА2230, МА0202 (µA, mA, mV, kV, V ) М42301, М42305М1400, M2003-M1, МА0201, МА0203, EА2232, EВ2233, EА2233
(µA, mA, A, mV, V ) М42300, М42304
М2001/1-M1, М2001-М1, EА2230 (µA, mА, А, kА, mV, V, kV ) М42305 ,М42301
EА2233, EV0201, EV0203 (mA, A, V, kV ) М42300EА2239 (µA, mA) М42306 , М42303EА2240 (µA) М42304
М381, M2027-M1, МА0200 (µA, mA, A, kA, mV, V, kV ) М4264М, M4265М
М381-1, М311-3, М300, М330, М325, М367, М309
(mA, A, kA, mV, V, kV ) М4272, M4273М
M2027-M1 (120х105mm, acc. cl. 0,5; 1,0; 1,5) М900, М903, М906 (120х105mm, acc. cl. 1.0; 1.5; 2.5
(µA, mA, A, kA, mV, V, kV )
М4264М, M4265М (120х120mm, acc. cl.
1.5, 2.5)М311-1 (mA, A, kA, V ) М4276
М42180 (A) current indicator М4263.8, М42163
EА0200, EА0302, EВ0302 (А, kА, V ) E42700E365-1, E365-2, E377, EА2258М, EV2259М, Ts33-М1, Ts330М, E309, EА3004, EV3004
(mA, А, kA, V, kV ) E42702, Ts42702
Е349, Е311-2 (mA, A, kA, V ) Ts42704, E42704Е350, Е311-3 (mA, A, kA, V, kV ) Ts42703, E42703Е349 (A, kA,V,kV ) Ts42704, E42704E8030-М1, E8031-М1, E8032-М1, E8033, E8035-М1 (mA, A, kA, V, kV ) E42700, Ts42300
E8004, E8036 frequency meter Ts42307D350, Ye340 wattmeter Ts42308
R3033 add. resistnace R4201
S300М1 frequency meter Ts42304S300М1-1 frequency meter Ts42306S302М1-1 phase meter Ts42309Ts302/1 phase meter Ts42305
Ts301, D37, D307, D367 1-phase wattmeter Ts42303/1
Ts301/1, D365, D335, D36, D366, D368, D345, D350, D351 3-phase wattmeter Ts42303
Ye340А, Ye340-3-1 1-phase wattmeter Ts42308/1
Shunt 75ShS, 75ShSM 5...7500 A Shunt 75ShIS, 75ShISV
Ye842, Ye1842, Ye854, Ye855, EP8542, EP8554, EP8555
AC and voltage transducers YeP34С, Ye854YeL
Ye856, Ye857, Ye875, Ye846, EP8556, EP8557, AEDC856, AEDC857, AEDC875
Direct current and direct voltage
transducersYe856YeL
Ye849, Ye859, Ye848, EP8530М power transducer Ye849YeL
SА(V)3020, TsА9054, TsV9055, TsP8501, SА3021 TsV2131АS, TsА2131,TsV2101, TsА2101, RА194I, RA194U
dig. А, В AC and voltage meters
SchP02.01, SchP02, SchP72, SchP96,
SchP120, SchP02P, SchP72P, SchP96P,
SchP120P
F1761.(3,5,6), F1762(1,2,3,4,5,6,7,8)-АD
digital meters for NPP
Sch10, Sch12, B10А, К12А, Sch20.3, Sch21.3,
Sch22.1, Sch22.2,Sch22.4, Sch23.3,
Sch23.4
F1761.(3,5,6), F1762(1,2,3,4,5,6,7,8)AD
digital meters for NPP
Sch10, Sch12, B10А, К12А, Sch20.3, Sch21.3,
Sch22.1, Sch22.2,Sch22.4, Sch23.3,
Sch23.4
М1620 pointer meters for NPP М42248
М1611.1, М1611.2, Ts1611, Ts1611.2 А, V М42412, М42408,
Ts42412, Ts42408
F1775 digital meter К02P
Type Unit of measu- rement
JSC “Electropribor”
meter typeSR3020, TsP8506, TsL9049, SK3021,SR3021, TsL9249Ye, SТ3021, TsL9259, PS194P, PS194Q, PD194PQ
dig. 3-ph. W-VAr TsP8506-120, SchV120
Т-0.66, TOP-0.66U3 current transformers TOP 0.66PD194Z, PD194PQ, РМ130, РМ710, DMK20, TsP8507 multi-meters SchМ120
RM175, Binom3, Resurs-Ye4 PQ monitoring meter SchМK96, SchМK120S
ENIP-2, АЕТ411, YeТ411, SN3020, PI849Ts, TsP8507
multifunctional transducers E900EL
DDD-ICE Display panel MI120
B10А mA, mV, V Sch20.3
K12А mA, mV, V Sch22.4М4200, М4204 (>= 100µA), М4233, М4252 (>= 100µA), М4254, М4258, М4260 (>= 100µA), М4262, М42100, М42102 (>= 100µA),М42104 (>= 100µA), М42175, E4201, М4250, М4256 (>= 100µA), М42304 (>= 100µA)
(mA, A, kA, V, kV ) М42300
М4202, М4205 (>= 100µA), М4255, М4259, М4261 (>= 100µA), М4263, М42101, М42103 (>= 100µA), E4202, М4251, М4257 (>= 100µA), М42305 (>= 100µA)
(mA, A, kA, V, kV ) М42301
М4203,М4206 (>= 100µA), М4224, М4230, М4231, М42306 (>= 100µA) (mA, A, kA, V, kV ) М42303
М4204 (< 100µA), М42007, М4210, М4213, М4220, М4221, М4240, М4252 (< 100µA), М4260 (< 100µA), М42102 (< 100µA), М42104, М4256 (< 100µA), EА0630, EV0630, EА0632
(mA, A, kA, V, kV ) М42304
М4205 (< 100µA), М42008, М4211, М4241, М4261 (< 100µA), М42103(< 100µA), М42105, М4257 (< 100µA), EА0633
(µA, mV ) М42305
М4206 (< 100µA), М42009, М4212, EА0634 (µA, mV ) М42306
М42148 (µA) М4248М4264 (mA, A, kA, V, kV ) М4264ММ4265 (µA, mV ) М4265ММ42272 (mA, A, kA, V, kV ) М4272(с)М42276 (mA, A, kA, V, kV ) М4276(с)М42272 (µA, mV ) (µA, mV ) М4273М(с)М42276 (µA, mV ) (µA, mV ) М4277М(с)М42202, EА0624 (µA , mA, A, kA, V, kV ) М42201М42203, EА0620,EА0623 (µA , mA, A, kA, V, kV ) М42200EА0607, EV0607 (mA, A, kA, V, kV ) М42607EА0608, EV0608, EА0611 (>= 100µA) (µA , mA, A, kA, V, kV ) М42608EА0609, EV0609, EА0612 (>= 100µA) (µA , mA, A, kA, V, kV ) М42609EА0610, EV0610 (µA, mV ) М42610EА0611 (< 100µA), EV0611 (up to 50 µA, mV ) М42611EА0612 (< 100µA), EV0612 (up to 50 µA, mV ) М42612EА0670, EV0670 (µA, mV ) М42670Ts4200, Ts4204, Ts4204М, Ts4281, Ts42175 (µA , mA, V ) Ts42300
Ts4201, Ts4202, Ts4205 (µA , mA, V ) Ts42302EV0702, EА0705 (µA , V, kV ) Ts42702EV0703 (V, kV ) Ts42703EV0704 (V, kV ) Ts42704
EА0700, E4204, E4204.10 (A, kA, 20A, 30A, 50A, 100A) E42700
EА0701, E4205 (V, kV, A, kA, 20A, 30A, 50A, 100A) E42701
EА0702, EА0702.10, E42702(к) (A, kA) E42702EА0703, EА0703.10, EV0703.10, EА0706, E42703(к) (A, kA,V, kV ) E42703
EА0704, EА0707 (A, kA) E42704М4245 (mA, A, kA, V, kV ) М42301(p)М4273 (µA, mV ) М4273ММ4277 (µA, mV ) М4277М
YeP34D AC and voltage transducers E854EL
Е34Direct current
and direct voltage transducers
E856EL
CONTACTS
General DirectorNikolay P. YermoshkinTel.: (8352)399-910, 399-912Fax: (8352) 561-593E-mail: [email protected]
Chief Financial Officer(Ph.D.)Sergey A. KalinovskyTel.: (8352) 563-668Fax: (8352) 561-593E-mail: [email protected]
Deputy Director(Ph.D.)Valery Ye. SlesaryovTel.: (8352) 399-960, 560-106Fax: (8352) 562-562E-mail: [email protected]
Technical DirectorAleksey V. DolzhenkovTel.: (8352) 399-942Fax: (8352) 554-269E-mail: [email protected]
Deputy Quality General Director(Ph.D.)Anastasiya V. GoldsteinTel.: (8352) 399-895Fax: (8352) 561-593E-mail: [email protected]
Sales DepartmentTel.: (8352) 399-824, 399-914Fax: (8352) 561-625, 555-002E-mail: [email protected]
Marketing DepartmentTel.: (8352) 399-971, 399-918Fax: (8352) 562-562E-mail: [email protected]
Procurement DepartmentTel.: (8352) 399-815, 399-961, 399-995Fax: (8352) 556-356E-mail: [email protected]
Special Design BureauDigital Meters SectorTel.: (8352) 399-849, 399-867E-mail: [email protected]
Special Design BureauAnalogue Meters SectorTel.: (8352) 399-931, 554-269Fax: (8352) 556-356E-mail: [email protected]
Quality Control and Management DepartmentTel.: (8352) 399-836, 399-953Fax: (8352) 555-002, 561-593E-mail: [email protected]
Chief Mechanic’s ServiceTel.: (8352) 399-911Fax: (8352) 554-269E-mail: [email protected]
Address:Tel.:Fax:
E-mail:
3, I.Yakovlev Prospect, Cheboksary, 428020(8352) 399-918, 399-971(8352) [email protected]