Case Study – IEC 62368-1
Maxi Tsai
Director, Global High Tech Business Unit
CSA Group
Safety
Colors in HBS 62368-1…
Safety is Colorful…
State of HBS 62368-x
FAQ - 5Ws & 1H
• What else in HBS 62368-x family? Who are they?
• Who (Which country) has already adopted it as national
standards?
• When will them be effective?
• What are those changes expected in the next edition (3rd) of
IEC 62368-1?
• How to manage the potential impact & a better transition?
HBS 62368-x family
Edition Status Publish date
IEC 62368-1 2ndAudio/video, information and communication
technology equipment - Part 1: Safety requirementsPublished 2015
IEC 62368-1 3rdAudio/video, information and communication
technology equipment - Part 1: Safety requirementsDraft 2018
IEC TR 62368-2 1st
Audio/video, information and communication
technology equipment - Part 2: Explanatory
information related to IEC 62368-1
Published 2015
IEC TR 62368-2 2nd
Audio/video, information and communication
technology equipment - Part 2: Explanatory
information related to IEC 62368-1
Draft 2018
IEC 62368-3 1st
Audio/video, information and communication
technology equipment - Safety - Part 3: DC power
transfer through communication cables and ports
Draft 2017
IEC 62949 1st
Particular safety requirements for equipment to be
connected to information and communication
networks
FDIS - ready to publish 2017
IEC 62911 1stAudio, video and information technology equipment -
Routine electrical safety testing in productionPublished 2016
IEC 60990 3rdMethods of measurement of touch current and
protective conductor currentPublished 2016
Global Adoption of IEC62368-1 2nd Edition (as of June, 2015)
Proposal for revised technical requirement for Clause 6.4.8 Fire Enclosures and Barriers of IEC 62368-1.
ASSESSING SIDE OPENINGS AS BOTTOM OPENINGS PER IEC62368
Illustration 1 (Side View) - With a PIS at the edge ofthe component zone, the bottom portion of theflame cone extends through the side vents
Illustration 2 (Rear View) - With a PIS at the edgeof the component zone, the bottom portion of theflame cone extends through the side vents
Complies with
IEC60950 5 degree rule
ASSESSING SIDE OPENINGS AS TOP OPENINGS PER IEC62368
Illustration 3 (Side View) - With a PIS at the
edge of the component zone, the topportion of the flame cone (cone straightwith no airflow considerations) extendsthrough the side vents
Ilustration 4 – Rear View - With a PIS at the edge of the component zone,
the top portion of the flame cone (cone straight with no airflow
considerations) extends through the side vents
Illustration 5 – Side/Rear View - With a PIS at the edge of the component zone, the top portion of the flame cone (45 degree angle with airflow considerations) extends through the side vents considerably more
Proposal for revised technical requirement for Clause 6.4.8 Fire Enclosures and Barriers of IEC 62368-1.
• IMPACT: Manufacturers and industry are faced with:
– Retooling chassis’ s of existing products to meet IEC62368 fire enclosure requirements to reduce size of side ventilation openings;
– Increase fan speeds to generate more air volume to hopefully generate enough cooling with regards to more restrictive ventilation opening sizes
– The need for faster fan speeds will increase product power and acoustic noise (increase in power will pose additional challenges with regards to energy efficiency and cooling standards)
– At the data center infrastructure level industry consortiums already are raising significant challenge concerns for cooling, power delivery, acoustics and energy consumption, server farm upgrades, etc.
• Proposed Changes:
– 5 Degree Rules – Adding back
• The IEC60950 5 degree rule for side opening (IEC 60950-1, Figure 4E) is a proven safeguard that maintains the integrity of the fire enclosure. This construction has been used in IT equipment for many years and has been shown to be effective. It is also used in other product safety standards including IEC 60601 for medical devices.
– 45 Degree Airflow Considerations - Remove from IEC62368-1 3rd ed.
• The current 6.4.7.2/Fig. 39 air flow requirements were added to 62368-1 to address the theoretical influence of airflow on the application of separation requirements (fire cone). However, in their present form these requirements have more of a theoretical basis than they allow for practical application. (TR 62368-2 (4.7.2/Fig 30) provides theoretical rationale only, but no Source of the requirements, nor reference to actual research.)2368-1
“It’s more than a gap analysis”
• Product life span till the end of 2018?
• Product type: Class III? Class I/II?
• Power consumption?
Product Type & Road Map
• Identify affected safety critical component, material, Power Supplies…
• Readiness of suppliers?
Supply Chain Management
• Qualifications of new vendors?
• Implement new testing procedures, design rules…
Procedures, Design Guideline
• Preparing the new testing gadgets, equipment.
• Calibrations…
New Testing Equipment
• Technical trainings to Compliance, R&D, PMs Team
Learning Curve
How to manage the impact and a better transition?
Appendix
17
Established in 1919
Independent, not-for-profit
Global leader in standards
development, product testing and
certification, product evaluation
18
Accreditations and Recognitions
Accreditations and Recognitions
19
EMC
MID
011
Accreditations and Recognitions
20
CSA Group Marks
21
Customers
22www.mi-technology.com
Who Uses the CSA Group Marks?
23