Consultant Worcestershire Council Client EMS Sector Education Products MasterFlue System Equipment Hamworthy PV110c Application Condensing 0844 809 2509 | airtherm.co.uk | [email protected] Project Profile Swan Lane First School, Evesham Front Entrance Airtherm Masterflue Airtherm Engineering Limited has recently completed a flue installation, working closely with the contractor, providing technical data and drawings at Swan Lane First School, Evesham, Worcestershire. The flue system selected is a stainless steel fully welded twin wall 4 hour fire rated system with 30mm insulation. Airtherm provided a cost-efficient solution for the client, and furthermore we exceeded their expectations when our tender was some margin under the original budget offered by the Hamworthy flue division. The flue system installed comprised of a 2.5m horizontal run and a 3m vertical, incorporating the necessary drains to allow any unwanted condense to evacuate the system. Twin Wall Flue System Vertical Stack

Case study for swan lane

Embed Size (px)

DESCRIPTION

The flue system selected was a stainless steel fully welded twin wall 4 hour fire rated system with 30mm insulation. Airtherm provided a cost-efficient solution for the client and furthermore we exceeded their expectations when our tender was some margin under the original budget offered by the Hamworthy flue division. The flue system installed comprised of a 2.5m horizontal run and a 3m vertical, incorporating the necessary drains to allow any unwanted condense to evacuate the system

Citation preview

Page 1: Case study for swan lane

Consultant

■ Worcestershire Council

Client

■ EMS

Sector

■ Education

Products

■ MasterFlue System

Equipment

■ Hamworthy PV110c

Application

■ Condensing

0844 809 2509 | airtherm.co.uk | [email protected]

Project Profile

Swan Lane First School, Evesham

Front Entrance

Airtherm Masterflue

Airtherm Engineering Limited has recently completed a flue installation, working closely with the contractor, providing technical data and drawings at Swan Lane First School, Evesham, Worcestershire.

The flue system selected is a stainless steel fully welded twin wall 4 hour

fire rated system with 30mm insulation.

Airtherm provided a cost-efficient solution for the client, and furthermore we

exceeded their expectations when our tender was some margin under the

original budget offered by the Hamworthy flue division.

The flue system installed comprised of a 2.5m horizontal run and a 3m

vertical, incorporating the necessary drains to allow any unwanted condense

to evacuate the system.

Twin Wall Flue System

Vertical Stack

British Standards The products we use are approved and CE marked to EN 1856-1 and

manufactured under a quality assurance scheme, certificate no

issued upon request, administered by British Standards in

accordance with BS EN 9001: 2008.

Page 2: Case study for swan lane

• Boilers: Hanmworthy

• Model: Modumax Variheat PV110c

• Application: Chimney / Flue system

• Operating mode: Wet

• Pressure: Negative / positive pressure

• Working pressure: 200 Pa (product will operate 1000pa max)

• Inner wall: 316L1.4404/1.457 thickness ≤ Ø250 0,4 mm

• Outer wall: AISI 304/ 1.4301 thickness 0,5 / 0,6 mm

• Insulation: 30mm thick Rockwool insulation

• Sealant : tri-lip 'o' type silicone ring

• Fuel type: Gas

• Other Application METALOTERM MasterFlue

• Condensing boilers

• Atmospheric gas-fired boilers

• Gas blown boilers

• Industrial ovens, large-scale establishments

• Wood-fired stoves

• Other Advantages METALOTERM MasterFlue

• No terminal bridges, better heat protection

• High-temperature silicone sealing ring

• Fast-build system without the need of sealants

• High quality insulation uninterrupted from base plate to top stub

0844 809 2509 | airtherm.co.uk | [email protected]

Product Solution

Airtherm Masterflue

Contact Details:

Airtherm Engineering Ltd

Ventilation House

Pedmore

Stoubridge

West Midlands

DY9 0DS

Tel: 0844 8092509

Fax: 01562 887312

MasterFlue