document.xls Page 1 of 4 01/19/2022 AccuSine Power Correction System (PCS) Selection Program 9. Be sure to use harmonic distortion percentages based upon the fundamental current not total 'RMS' current. Project Identification: Date: Company name: Job ID Address: Ref #: City: St: Completed by: Postal Code: Contact Phone #: Fax #: e-mail ID: Comments: Electrical System Data A. Desired TDD level to be met: 5.0% Isc/Iload TDD Input Transformer Information < 20 5% A1.a. KVA: KVA 20<50 8% 50<100 12% A1.b. Impedance: Impedance 100<1000 15% A1. Short circuit current (SCC): 0.0 SCA >1000 20% A2. Total demand load: amps Enter if known. Program will calculate demand load based upon loads defined below if not provided. A3. Short cicuit ratio (A1/A2): SCR (Isc/Iload B. Electrical system voltage: V If no value is entered for voltage, 480V is assumed. AccuSine PCS is designed to correct for harmonics and poor displacement power factor. By completing the following information, this program will define the amount of corrective current to be provided by AccuSine PCS to meet the obje 1. Review site carefully to determine all of the loads to which AccuSine PCS will be applied. AccuSine PCS is best ap a common bus. Be sure to include all loads for proper evaluation. 2. Be sure there are no power factor capacitors downstream of the selected CT location. Any and all capacitors downs the CTs must be removed or AccuSine PCS performance will be diminished greatly and/or resonance may occur. Removal of these filters is best. However, if removal is not possible, insertion of a series line reactor in front of filter is required. 4. Use of series line reactors in front of all SCR type converters is best for optimum reduction in harmonics. In so line reactors may be required due to the design of the SCR converter. Consult PQc if questions arise. 5. PWM VFDs require either a DC bus choke or an input line reactor for optimum operation with AccuSine PCS. 6. If AccuSine PCS is on an electrical system that contains a combination of linear and nonlinear loads, all linear l be grouped as if they were one load for the purposes of this selection program. 7. When TDD (total demand distortion of the current) is maintained below 5%, the upstream total harmonic voltage dist [THD(V)] will not exceed 5% THD(V). system voltage. objective. 10.3 guidelines, leave "A" blank and enter the "Input Transformer Information" below.) Current Distortion Limits (120 t V) Table 10.3 of IEEE 519-1 Power Quality Correction Group (PQc) 255 Orenda Road Bramalea Ontario L6T 1E6 905-459-8805 905-454-3603 Fax www.Reactivar.com

Calculo de Filtros Armonicos Accusine

Embed Size (px)

Citation preview

Input DataAccuSine Power Correction System (PCS) Selection ProgramAccuSine PCS is designed to correct for harmonics and poor displacement power factor. By completing the following information, this program will define the amount of corrective current to be provided by AccuSine PCS to meet the objective.1. Review site carefully to determine all of the loads to which AccuSine PCS will be applied. AccuSine PCS is best applied to a common bus. Be sure to include all loads for proper evaluation.2. Be sure there are no power factor capacitors downstream of the selected CT location. Any and all capacitors downstream of the CTs must be removed or AccuSine PCS performance will be diminished greatly and/or resonance may occur.3. Nonlinear loads with input EMI filters may interact with AccuSine PCS to prevent proper operation of AccuSine PCS. Removal of these filters is best. However, if removal is not possible, insertion of a series line reactor in front of the EMI filter is required.4. Use of series line reactors in front of all SCR type converters is best for optimum reduction in harmonics. In some cases line reactors may be required due to the design of the SCR converter. Consult PQc if questions arise.5. PWM VFDs require either a DC bus choke or an input line reactor for optimum operation with AccuSine PCS.6. If AccuSine PCS is on an electrical system that contains a combination of linear and nonlinear loads, all linear loads may be grouped as if they were one load for the purposes of this selection program.7. When TDD (total demand distortion of the current) is maintained below 5%, the upstream total harmonic voltage distortion [THD(V)] will not exceed 5% THD(V).8. AccuSine PCS selection is based solely upon current requirements. Be sure to select the correct model that matches your system voltage.9. Be sure to use harmonic distortion percentages based upon the fundamental current not total 'RMS' current.Project Identification:Date:Company name:Job ID:Address:Ref #:City:St:Completed by:Postal Code:Contact:Phone #:Fax #:e-mail ID:Comments:Electrical System DataThis program requires no data entry for the "Electrical System Data." The program defaults to 480VAC and 5%TDD as the objective.A. Desired TDD level to be met:5.0%(If you want the objective TDD to be selected according to IEEE 519-1992, Table 10.3 guidelines, leave "A" blank and enter the "Input Transformer Information" below.)Current Distortion Limits (120 to 69,000 V) Table 10.3 of IEEE 519-1992Isc/IloadTDDInput Transformer Information< 205%A1.a. KVA:KVA20