    QUINCY AIR SYSTEMS

    FILTERS

    COALESCERS

    ABSORBERS

    ELEMENTS

    The Science of Compressed Air

  • 7/29/2019 Filtros Quincy

    2/12

    C O M P R E S S E D A I R F I LT E R S

    STANDARD FILTERS

    Particulate Coalescer Absorber

    Our Standard Filtration lineup consists of the threemost common types of filters used in compressedair systems.

    THE QUINCY DCN SERIES

    Particulate/Coarse Coalescer is designed to removesolids, burnt oil and bulk liquids.

    THE CSN, CPN, CXN SERIES

    Coalescers remove various levels of liquid aerosolsand mist.

    THE ACN SERIES

    Activated Carbon Absorbers remove vapors andodors.

    10 scfm to 16,500 scfm

    230 psig max. working pressurefor threaded filters

    150 psig max. working pressurefor flanged filters

    Aluminum housing (12" to 3" NPT)

    Steel housing (3" to 12" FLG)

    MOISTURE SEPARATORS

    20 to 1500 scfm, 230 psig

    Aluminum housing ( 14" to 3" NPT)

    OVER & UNDER

    COALESCER/ABSORBER

    COMBINATION

    10 to 50 scfm/230 psig

    Two-in-one design

    BREATHABLE AIR SYSTEMS

    FOR PAINT OR SANDBLAST

    APPLICATIONS(Will not remove certain types ofgases, including CO or CO2 )

    15 cfm two-port manifold

    30 scfm, four-port manifold

    230 psig max. working pressure

    Floor stand or wallmounting brackets Air pressure regulator

    Air pressure gauge

    Available air heater

    HIGH-TEMPERATURE

    DUST FILTER

    +450F/150 psig

    15 to 1600 scfm

    Quincy Filters protect pneumatic equipment and processes from the harmful effectsof contaminated compressed air by removing dirty water, burnt oil and solid pollutants

    before they can do any damage. Clean compressed air will result in improved productionand reduced operating costs. World class, state-of-the-art material and design make QuincyCompressed Air Filters the standard to which all others must be compared.

    QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air2

  • 7/29/2019 Filtros Quincy

    3/12

    The Science of Air Treatment

    ELEMENT CONSTRUCTION

    Push-to-Fit Design Aluminum Filters

    Easy element replacement

    Fit integrity eliminates leaks,saving energy

    Stainless Steel Support Core Provides strength

    Eliminates corrosion

    Protects element from burstingunder high differential pressure

    1st Stage Pre-Filtration Support Layer

    Captures larger contaminates

    Protects 2nd Stage filtration media

    Extends service life

    Multiwrap 2nd Stage

    High void volume minimizespressure drop, saving energy

    Increased surface area ensuresmaximum contaminant retention

    Extended life construction

    Deep bed provides optimumcoalescing efficiency

    Selected media combinationsprovide precise filtration solutions

    3rd Stage Interceptor Layer

    Provides additional strength

    Optimizes interception process

    4th Stage Outer Stainless Steel Support

    Ensures total element integrity

    Inside to Out Flow

    Prolongs element life andimproves drain performance

    Polyester Needle Felt Drainage Layer

    Optimum oil removal

    High temperature tolerance

    Maximum durability

    Will not disintegrate Suitable foruse with mineral

    and synthetic oils

    Tolerant in aggressive environments

    Glass-Filled Nylon End Caps

    Color-coded for simple elementgrade identification

    Easy element replacement

    Will not corrode

    Quincys Layered Multiwrap design employs a specially blended borosilicate glassmicrofiber media to produce strong, durable and efficient filter elements. The filtrationmedia combines high flow rates and high dirt-holding capacities without compromising

    element service life. Easy to identify and easy to install, these highly advanced productsoffer the best performance available

    ELEMENTS

  • 7/29/2019 Filtros Quincy

    4/12

    C O M P R E S S E D A I R F I LT E R S

    STANDARD LINE PARTICULATE COALESCER ABSORBER

    Quincys Standard Filtration lineup consists of the three most common types of filters used

    in compressed air systems. Aluminum housings with threaded NPT connections are usedfor flows up to 1530 cfm and steel housings with flanged connections are used for flowsup to 16,500 cfm.

    Push-to-fit designused on threaded filters for easy

    filter element replacement

    Multiwrap element construction ensures optimum

    performance

    Modular design saves energy and allows for easy

    installation of multiple threaded filters

    Aluminum housings feature electrophoretic coating

    to prevent corrosion 10-year housing guarantee on aluminum housings

    Standard pressure differential indicator

    Standard automatic condensate drain

    STEEL HOUSINGS,

    FLANGED CONNECTIONS 1500 TO 16,000 CFM

    SERIES DCNF, CSNF, CPNF, CXNF AND ACNF

    DCNT SERIES

    Designed to remove highconcentrations of solids,burnt oil and bulk liqu id s

    DCNT 5 micron, 5 ppm

    CSNT, CPNT, CXNT SERIES

    Designed to coalesce variouslevels of liqu id aerosols. The1 micron CSN is also an ideal

    afterfilter for desiccant dryers.

    CSNT 1 micron, 0.1 ppm

    CPNT .01 micron, .01 ppm

    CXNT .01 micron, .001 ppm

    ACNT SERIES

    Activated Carbon Absorberdesigned to remove vaporsand odors. Installed imme-

    diately downstream ofeither a CPNT or a CXNTcoalescer, itwill reduceoil carryoverto .003 ppm.

    Same filtration grade as aluminum filters

    Identified with an F suffix

    U stamped for the USA and CRN approved for Canada

    Housings are freestanding and top loading for easy element replacement

    All grades of filter element end caps are molded, providing strength,

    durability and long life

    ALUMINUM HOUSINGS,

    THREADED CONNECTIONS 10 TO 1530 CFM

    QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air4

  • 7/29/2019 Filtros Quincy

    5/12

    The Science of Compressed Air

    Grade 10 14 10 17 Grade E 10 1 3 112 8 3 1.43 0.65 72 35 210 75Grade 20 14 20 33 Grade E 20 1 3 112 8 3 1.43 0.65 72 35 210 75Grade 30 38 30 50 Grade E 30 1 3 112 8 3 1.43 0.65 72 35 210 75Grade 60 12 60 100 Grade E 60 1 312 114 13 4 2.87 1.30 88 32 315 100Grade 125 34 125 208 Grade E 125 1 5 112 15 4 5.95 2.70 125 39 365 100Grade 150 1 150 250 Grade E 150 1 5 112 15 4 5.95 2.70 125 39 365 100Grade 200 1 200 333 Grade E 200 1 5 112 21 6 7.72 3.50 125 39 515 150Grade 300 114 300 500 Grade E 300 1 5 112 21 6 7.72 3.50 125 39 515 150Grade 425 112 425 708 Grade E 425 1 512 2 22 6 9.70 4.40 135 50 545 150Grade 500 2 500 833 Grade E 500 1 512 2 22 6 9.70 4.40 135 50 545 150Grade 650 2 650 1083 Grade E 650 1 512 2 30 6 11.00 5.00 135 50 745 150Grade 800 212 800 1333 Grade E 800 1 8 2 34 32 8 25.40 11.50 200 68 805 200Grade 1000 3 1000 1667 Grade E 1000 1 8 2 34 32 8 25.40 11.50 200 68 805 200Grade 1300 3 1300 2167 Grade E 1300 1 8 2 34 37 8 34.20 15.50 200 68 925 200Grade 1525 3 1525 2542 Grade E 1525 1 9 212 42 12 41.90 19.00 230 65 1050 300

    STANDARD LINE SPECIFICATIONS & ENGINEERING DATA

    MetricElement Number Dimensions DimensionsFilter Model Pipe Size Flow Rate Model of A B C D Weight A B C D(Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

    Complete Filter Assemblies

    Grade 1503 3 1500 2550 Grade 1500 1 58 15 48 10 165 74 1472 381 1219 254Grade 1504 4 1500 2550 Grade 1500 1 58 1718 48 612 175 80 1473 435 1219 165Grade 2004 4 2000 3400 Grade 2000 1 58 2138 4814 13 320 145 1473 543 1226 330Grade 2006 6 2000 3400 Grade 2000 1 5914 2512 48 712 360 163 1505 648 1219 191Grade 3004 4 3000 5100 Grade 3000 1 72 2138 6214 13 385 175 1829 543 1581 330Grade 3006 6 3000 5100 Grade 3000 1 7514 25.5 64 712 420 191 1911 648 1626 191Grade 4506 6 4500 7650 Grade 1500 3 8312 2514 6812 2312 580 263 2121 641 1740 597Grade 6008 8 6000 10200 Grade 1500 4 8634 25 68 23 650 295 2203 635 1727 584Grade 10510 10 10500 17850 Grade 1500 7 100 31 80 30 800 363 2540 787 2032 762Grade 16512 12 16500 28050 Grade 1500 11 11334 4412 87 16 1000 454 2889 1130 2210 406

    MetricElement Number Dimensions Dimensions

    Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D(Grade) Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

    DCNE 3 4 5 5.0 5.0 248 120 1 40 1 75 6 400 232 16 GreenCSNE 2 2 1 0.1 0.1 248 120 1 75 2 150 6 400 232 16 RedCPNE 1 1 0.01 0.01 0.01 248 120 2 100 4 300 6 400 232 16 BlueCXNE 1 1 0.01 0.001 0.001 248 120 2 140 5 350 6 400 232 16 BlackACNE 1 1 0.01 0.003 0.003 77 25 1 75 Min.every 6 months 232 16 Black

    Max. Pressure Loss Max. ElementMax. Particle Oil Carryover Max. Change Working End Cap

    Filter Max. Particle Size Oil Content Class Removal at 68F at 20C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 F C psi mbar psi mbar psi mbar psig barg Code

    Specs

    Steel Housings Flanged

    Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51

    For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.

    Correction Factor

    Model Grades 10, 20 & 30 Model Grades 601525

    Model Grades 1503, 1504& 2004

    Model Grades 200616512

    A

    C

    D

    A

    C

    B

    B

    D

  • 7/29/2019 Filtros Quincy

    6/12

    C O M P R E S S E D A I R F I LT E R S

    HIGH TEMPERATURE 1 MICRON DUST FILTERS, 450F, 150 PSIG

    Features a high-temperature dust filter

    with heavy-duty bowl

    Ribbed bowl facilitates removal when

    changing elements

    NOTE: Alloy filters shipped loose will have a special

    high-temperature black powder coat paint.

    Nomex outer layer is provided for high-temperature operation

    Push-to-fit designused on threaded filters for easy filter element replacement

    Multiwrap element construction provides optimum performance

    ALUMINUM HOUSINGS,

    THREADED NPT CONNECTIONS

    15 TO 650 CFM,

    SERIES HTDT

    Same filtration grade as aluminum filters

    Identified with an F suffix

    U stamped for the USA and CRN approvedfor Canada

    Differential pressure indicators are standard

    Housings are freestanding and top-loading

    for easy element replacement

    All grades of filter element end caps are

    molded, providing strength, durability

    and long life

    STEEL HOUSINGS,

    FLANGED CONNECTIONS

    1500 TO 16,000 CFM,

    SERIES HTDF

    QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air6

  • 7/29/2019 Filtros Quincy

    7/12

    The Science of Compressed Air

    HTDT 15 14 15 25 HTDE 15 1 212 12 6 2 0.5 0.25 63 15 150 50HTDT 30 38 30 50 HTDE 30 1 212 12 712 2 0.6 0.27 63 15 190 50HTDT 65 12 65 108 HTDE 65 1 412 112 12 6 5.7 2.60 114 38 305 150HTDT 75 34 75 125 HTDE 75 1 412 112 12 6 5.7 2.60 114 38 305 150HTDT 150 1 150 250 HTDE 150 1 412 112 1512 6 7.3 3.30 114 38 395 150HTDT 300 112 300 500 HTDE 300 1 534 2 21 7 16.5 7.50 146 50 435 170HTDT 450 2 450 750 HTDE 450 1 534 2 21 7 16.5 7.50 146 50 435 170HTDT 650 2 650 1084 HTDE 650 1 534 2 25 7 22.0 10.00 146 50 635 170

    HIGH TEMPERATURE SPECIFICATIONS & ENGINEERING DATA

    MetricElement Number Dimensions DimensionsFilter Pipe Size Flow Rate Model of A B C D Weight A B C DModel NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

    Dust Filters Threaded

    HTDF 1503 3 1500 2550 HTDE 1500 1 58 15 48 10 165 74 1473 381 1219 254HTDF 1504 4 1500 2550 HTDE 1500 1 58 1718 48 612 175 80 1473 435 1219 165HTDF 2004 4 2000 3400 HTDE 2000 1 58 2138 4814 13 320 145 1473 543 1226 330HTDF 2006 6 2000 3400 HTDE 2000 1 5914 25.5 48 712 360 163 1505 648 1219 191HTDF 3004 4 3000 5100 HTDE 3000 1 72 2138 6214 13 385 175 1829 543 1581 330HTDF 3006 6 3000 5100 HTDE 3000 1 7514 2512 64 712 420 191 1911 648 1626 191HTDF 4506 6 4500 7650 HTDE 1500 3 8312 2514 6812 2312 580 263 2121 641 1740 597HTDF 6008 8 6000 10200 HTDE 1500 4 8634 25 68 23 650 295 2203 635 1727 584HTDF 10510 10 10500 17850 HTDE 1500 7 100 31 80 30 800 363 2540 787 2032 762HTDF 16512 12 16500 28050 HTDE 1500 11 11334 4412 87 16 1000 454 2889 1130 2210 406

    MetricElement Number Dimensions Dimensions

    Filter Pipe Size Flow Rate Model of A B C D Weight A B C DModel Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

    Dust Filters Flanged

    High-temperature dust filter element gradeHTDE 1 2 2 450 250 1.1 75 NA NA 6 400 150 10 Brick Red

    Max. Pressure Loss Max. ElementParticle Oil Carryover Max. Change Working End Cap

    Filter Removal at 68F at 20C Temperature Clean & Dry Wet Element Pressure Color

    Element in Microns ppm mg/m3 F C psi mbar psi mbar psi mbar psig barg Code

    Specs

    ModelsHTDT 15 & 30

    ModelsHTDT 65650

    Operating psig 145 290 435 580 725Pressure barg 10 20 30 40 50Correction Factor 0.34 0.57 0.71 0.86 1.0

    For maximum flow rate, multiply model flow rateshown in the above table by the correction factorcorresponding to the working pressure.

    Correction Factor

    ModelsHTDF 1503, 1504 and 2004

    Models HTDF 200616512

    A

    C

    D

    A

    C

    B

    B

    D

  • 7/29/2019 Filtros Quincy

    8/12

    BREATHABLE AIR SYSTEMS

    15 TO 30 CFM

    Quincy Breathable Air Packages are completesystems designed to provide, clean, odor-free,taste-free, particle and liquid oil-free compressed

    air for sand blasting and/or painting hoods. The15-cfm system has two outlet ports and can

    accommodate two suits. The 30-cfm packagehas four outlet ports and can accommodate four

    suits. The system provides absolute filtrationdown to 0.01 micron and oil removal down to0.003 ppm. Special non-shedding, high-speed

    carbon granules increase vapor-holding capacity.

    The System Includes:

    Aluminum housings with electrophoretic

    coating to prevent corrosion

    WSNT moisture separator

    CSNT 1 micron, 0.1 ppm Coalescer

    QUDT with CPNT 0.01 micron, 0.01 ppm

    and .003 ppm activated carbon absorber

    Wallmounting or floor-mounting

    configuration

    The System includes:

    Combination Coalescer and Activated Carbon Absorber

    Two functions in one unit

    Space-saving Over & Under configuration

    Push-to-fit design for easy filter element replacement

    Multiwrap element construction ensures

    optimum performance

    Non-shedding, high-speed carbon granules

    increase vapor-holding capacity

    Aluminum housings with electrophoretic

    coating to prevent corrosion.

    Standard pressure differential indicator

    Standard automatic condensate drain

    Using a unique two-sided head, Quincys Over & Under Duplex filtercombines a CPN Series (0.01-micron, 0.01-ppm) coalescer with an

    ACN Series (.003-ppm) activated carbon absorber. This compact, two-stage, single-piece filtration system saves space, is easy to install and

    delivers ISO 8573.1 class 1 compressed air. The Over & Under is idealfor food and beverage, instrumentation and pharmaceutical applications.

    OVER & UNDER DUPLEX

    10 TO 50 CFM, SERIES OUDT

    C O M P R E S S E D A I R F I LT E R S

    Push-to-fit design

    PNF drain layer

    Pressure differential

    indicator

    Multiwrap construction

    Air pressure regulator

    and gauge

    Activated carbon element impregnated

    with red dye oil indicator

    Color-coded end caps

    Compressed air heater option

    QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air8

  • 7/29/2019 Filtros Quincy

    9/12

    The Science of Compressed Air

    WARNING: The Breathable air systems described in this brochurewill not remove certain types of gases, including Carbon Mon-oxide (CO) and Carbon Dioxide (CO2). These Breathable AirSystems are designed to offer the user protection in potentiallyharmful environments. It is therefore imperative the products be

    correctly installed and properly controlled by a competent person.Properly controlled means the equipment installed should befully checked prior to every use. Should any fault be discovered,it must be repaired or the failed component replaced to guaran-tee full working order before use.

    Wallmounted Breathable Air PackagesBWST 15 14 2 15 25 BAEK 15 1 Kit 1014 1234 1234 3 0.50 0.25 280 360 323 77BWHT 15 14 2 15 25 BAEK 15 1 Kit 1534 18 1314 4 0.60 0.27 418 498 337 100BWST 30 38 2 15 25 BAEK 30 1 Kit 1014 1234 1234 3 5.70 2.60 280 360 323 77BWHT 30 38 2 15 25 BAEK 30 1 Kit 1534 18 1314 4 5.70 2.60 418 498 337 100

    Frame-Mounted Breathable Air PackagesBFST 15 14 4 30 50 BAEK 15 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500BFHT 15 14 4 30 50 BAEK 15 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500BFST 30 38 4 30 50 BAEK 30 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500BFHT 30 38 4 30 50 BAEK 30 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500

    MetricPipe Air Element Number Dimensions Dimensions

    Filter Size Outlet Flow Rate Model of A B C D Weight A B C DModel NPT Ports scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

    Breathable Air Packages

    Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1.0 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51

    For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.

    Correction Factor

    Breathable Air Package KitBAEK 1 1 >0.01 >0.003 >0.003 77 25 3.7 250 6.6 950 Min.every 6 months 145 10 Red/Blue/Black

    Duplex Filter Kit (OUDK)CPNE 1 1 0.01 0.01 0.01 248 120 2.2 150 4.4 300 6 400 232 16 BlueACDE 1 1 0.01 0.003 0.003 77 25 1.1 75 NA NA Min.every 6 months 232 16 Black

    Max. Pressure Loss Max. ElementMax. Particle Oil Carryover Max. Change Working End Cap

    Filter Max. Particle Size Oil Content Class Removal at 68F at 20C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 F C psi mbar psi mbar psi mbar psig barg Code

    Specs

    OUDT 10 14 10 17 OUDK 10 1 Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT 15 14 15 25 OUDK 15 1 Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT 30 38 30 50 OUDK 30 1 Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT 50 12 50 83 OUDK 50 1 Kit 312 8 9 4 2.75 1.25 90 200 225 100

    MetricElement Number Dimensions Dimensions

    Filter Pipe Size Flow Rate Model of A B C D Weight A B C D

    Model NPT scfm Nm3

    /hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

    Over & Under Duplex

    ModelsBWST 15 & 30

    ModelsBFST 15 & 30

    ModelsOUDT 1050

    BREATHABLE AIR, OVER & UNDER DUPLEX SPECIFICATIONS & ENGINEERING DATA

  • 7/29/2019 Filtros Quincy

    10/12

    C O M P R E S S E D A I R F I LT E R S

    MECHANICAL MOISTURE SEPARATORS

    20 TO 1500 CFM, 230 PSIG, SERIES WSNT

    Quincy Mechanical Moisture Separators are designed to remove bulk liquids andlarge volumes of water. They are typically installed downstream of aftercoolers, air

    receivers, refrigerated air dryers and at strategic points of use throughoutthe compressed air distribution system. The design employs an

    internal spinner to create a centrifugal action that effectivelyremoves large quantities of water.

    Large sump and quiet zone to prevent moisture

    re-entrainment

    Modular design allows for easy installation

    of multiple housings and saves energy

    Annular seal and captive Oring prevent leaks

    Aluminum housings (14" to 3 NPT) feature

    electrophoretic coating to prevent corrosion

    Aluminum housings (14" to 3" NPT) carry

    a 10-year housing guarantee

    Standard automatic condensate drain

    WSNT 20 14 20 35 3 114 814 3 1.45 0.65 72 35 210 75WSNT 30 38 30 50 3 114 814 3 1.45 0.65 72 35 210 75WSNT 63 12 63 112 312 114 814 4 2.90 1.30 88 32 210 100WSNT 127 34 127 216 5 112 12 4 5.95 2.70 125 39 300 100WSNT 176 1 176 300 5 112 12 4 5.95 2.70 125 39 300 100WSNT 318 114 318 540 5 112 12 4 5.95 2.70 125 39 300 100WSNT 427 112 427 725 512 2 19 6 9.70 4.40 135 50 480 150WSNT 675 2 675 1150 512 2 19 6 9.70 4.40 135 50 480 150WSNT 1000 212 1000 1700 8 234 24 8 25.5 11.5 200 68 590 200WSNT 1500 3 1500 2550 8 234 24 8 25.5 11.5 200 68 590 200

    MetricDimensions Dimensions

    Filter Pipe Size Flow Rate A B C D Weight A B C DModel NPT scfm Nm3/hr In. In. In. In. lb. kg. mm mm mm mm

    Moisture Separators

    Operating psig 4 9 15 29 44 58 72 87 100Pressure barg 0.3 0.6 1 2 3 4 5 6 7Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1

    Operating psig 115 130 145 160 174 189 203 218 232Pressure barg 8 9 10 11 12 13 14 15 16Correction Factor 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51

    For maximum flow rate, multiply model flow rate shown in the above table by thecorrection factor corresponding to the working pressure.

    Correction Factor

    WSNT 248 120 35 1.5 0.7 50 232 16

    Max. Min. Typical Max.Recommended Recommended Pressure Loss Working

    Filter Operating Temp. Operating Temp. At Rated Flow PressureModel F C F C psi mbar psig barg

    Specs

    SPECIFICATIONS & ENGINEERING DATA

    QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air10

  • 7/29/2019 Filtros Quincy

    11/12

    The Science of Compressed Air

    QUINCY SYSTEM PRESSURE TRANSMITTERS

    Quincy System Pressure Transmitters sense pressure, differential pressure or both

    at specific points throughout a compressed air system. Accurate to half of 1%,a 4 to 20 mA signal continuously transmits readings to the systems main

    control station.

    Continuous and accurate pressure tracking facilitates periodic

    compressed air audits and enables the automation and/or operatorto monitor the system and adjust controls for optimum efficiency.

    Reduce energy and filtration costs

    Improve air treatment efficiency

    Monitor critical applications

    24/7 operation

    Simple and cost-effective installation

    Guaranteed for 5 years

    Rugged NEMA 4/IP65 rating

    ACCESSORIES

    Quincy filtration products come standard with mechanicalcondensate drains and are available with

    Optional electronic timer drains

    Optional pneumatic no-loss drains

    Optional electronic no-loss drains

    Quincy Filters are equipped standard with top-mounted pressure indicators.

    Pop-up for 10 cfm through 30 cfm

    ( 12" NPT & 3/8" NPT)

    Gauge for 50 cfm through 16,500 cfm

    ( 12" NPT through 12" FLG)

    Multiple filters can be ganged together using the available two- and three-unit

    connecting kits.

    Eliminates leaks, saving energy

    Easy and space-saving installation

    Aluminum Alloy filters can be wallmounted using the available wallmounting brackets.

    Provides easy and flexible installation

    1

  • 7/29/2019 Filtros Quincy

    12/12

    quincycompress or.com

    QGV-100quincycompressor.com

    QPNC-500quincycompressor.com

    QDHT-1000quincycompressor.com

    Air Quality ClassificationISO 8573.1

    Quincy Rotary Screw WSNBulk

    LiquidDP1

    WetReceiver

    1gal/CFMDP2

    DryReceiver

    5gal/CFM

    CSN1 Micron0.1 PPM

    DP3

    CPN0.01 Micron

    0.01 PPMDP5

    ACN0.003 PPMVapor &

    Odors

    Solids

    Micron ISO PDP ISO PPM ISO

    0.01 1 +38F 4 0.01 1 10.7 738

    0.01 1 +38F 4 0.003 1 11.8 814

    1 2 -40F 2 0.01 1 9.2 634

    0.01 1 -40F 2 0.003 1 10.3 710

    1 2 +50F 6 0.01 2 7.8 538

    0.01 1 +50F 6 0.003 1 10.0 689

    1 2 -40F 2 0.01 1 9.2 634

    0.01 1 -100F 1 0.001 1 14.2 979

    Moisture Oil

    psi Mbar

    Refrigerated Air DryerQPNC Non-Cycling

    QPCD CyclingDP4

    WetSystemAvg. P

    Quincy Reciprocating AC

    WSN Moisture Separator

    DCN Particulate/Coarse Coalescer

    CSN STD 0.1 PPM Coalescer, 1 Micron

    CPN Polishing 0.01 PPM Coalescer

    CXN Xtra 0.001 PPM Coalescer

    ACN Activated Carbon Absorber

    OUD Over + Under Duplex

    HTD High Temperature,1 Micron

    QPNC Non-Cycling Refrigerated Dryer

    QPCD Cycling Refrigerated Dryer

    QDTS Small Heatless Dryer

    QDTH Industrial Heatless Dryer

    QDHP Heated Purge Dryer

    QDBP Blower Purge Dryer

    QPHT High Temp. Refrigerated Dryer

    WOS Water/Oil Separator

    AC After Cooler

    DP Drain Point

    WSNBulk

    LiquidDP6

    DryReceiver

    5gal/CFM

    CPN0.01 Micron0.01 PPM

    DP7

    CSN (NPT)HTD (FLG)1 Micron

    Particulate

    ACN0.003 PPMVapor &

    Odors

    0.01 1 -40F 2 0.003 1 10.3 710

    ACN0.003 PPMVapor &

    Odors

    Desiccant Heatless Air DryerQDTSSmall

    QDTHIndustrial-40F PDP

    DCN5 Micron

    5 PPMDP9

    WOSWater/OilSeparator

    CSN1 Micron0.1 PPM

    DP11 CPN0.01 Micron

    0.01 PPM

    ACN0.003Micron

    OUD

    High Temperature/Refrigerated Air DryerQPHTHigh Temp.

    DP10

    DryReceiver

    5gal/CFM

    CPN0.01 Micron0.01 PPM

    DP8

    Desiccant Heated Air DryerQDHPHeated PurgeQDBPBlower Purge

    -40F PDP

    QDHP-1000quincycompressor.com

    Approximate Liquid Removal100 CFM, 100 psi, 80F, 4000 hrs./yr., 2 PPM

    DrainPoint

    1234

    30002000305

    1300

    Gallonsper Year

    DrainPoint

    5678

    1403000310310

    Gallonsper Year

    DrainPoint

    91011

    3004320120

    Gallonsper Year

    QPHT-40quincycompressor.com

    NOTE: Requires CXN (.001 PPM) filter in

    series with standard CPN prefilter.

    CSN1 Micron

    Particulate

    701 North Dobson Avenue | Bay Minette, AL 36507 | Phone 251.937.5900 | Fax 251.937.7182 | Nearest Distributor: 888.424.7729 | Email: [email protected]

    2005 Quincy Compressor anEnPro IndustriescompanyAll rights reserved. Litho in U.S.A. (QATF-001 03/05)

    The Science of Compressed Air

    COMPRESSED AIR SYSTEMS BEST PRACTICE