Upload
khainnd
View
217
Download
0
Embed Size (px)
Citation preview
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
1/37
HUAWEI
Whole Network StudyOverseas radio network planning department
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
2/37
General IdeaStep by Step
Huawei G18 co -locate with Nok ia G9
Count utilization of all G9 and G18 Co-location cells
Compare utilization of Huawei and Nokia cell
Find out reason of lopsided utilization
Provide possible solution
Huawei Util. Nokia Util. General Solution
Low Low Remove G9 or G18TRX if abnormal
Low High Remove G18 TRX or check
High Low Remove G9 or Add G18 TRX
High High New Site or Expansion
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
3/37
General IdeaStep by Step
No Huawei G18 co-locate wit h Nokia G9
Count utilization of all G9 cells excluding co-located site
Check those cells with high or low utilization
Provide possible solution
Nokia General Solution
Low Y Remove G9 if abnormal
Low N Check reason if abnormal
High Y New G9 or G18 Site or Expansion
High N Expansion
TRX >= 4
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
4/37
Distribution of Utilization
Huawei G1800
13 14 15 16
100%
9 10 11 12
80%
5 6 7 8
40%
1 2 3 4
0 40% 80% 100% Nokia G900
No HW Site A B C D
HW Site noton Service
E F G H
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
5/37
Major Solution
Parameter G18
Remove TRX G18
Add TRX G18
Change direction G18
Change feed or antenna
Add new site G18
Remove Site G18
Parameter G9
Remove TRX G9
Add TRX G9
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
6/37
CN Region
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
7/37
11
0
No G1800 88 392 40
0 1 0G18 not on
service
33 7
0 40% 80% 100% Ericsson G900
4 2
80%
5 109 20 740%
3 67
HuaweiG1800
1 0
100%
0 36
0 1
Distribution of Utilization(CN)
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
8/37
Detailed Solutions(CN)
Parameter G18 Add TRX G18 Remove TRX G18 Change feed or antenna Remove Site G18
34 27 43 26 3
Parameter G9 Add TRX G9 Remove TRX G9 Change direction G18 Add new site G18
47 26 18 3 13
Solution fo r Each Cel l:
Br ie f of Equipm ent Regulat ion:
Item Quantity Remark
Add TRX G18 31 -Remove TRX G18 -48 -
Sub-Total -17
Add TRX G9 26 -
Remove TRX G9 -20 -
Sub-Total 6
Add new site G18 8 Add 4 new sites and 4 new cells
Remove Site G18 3 Remove 3 cells
*Negative value means remove.
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
9/37
Case Study 1
- Change parameter of G9
*Change parameter of LAST3 to get more traffic from TLCS1 and
NGBK2, the same solution is applied in some areas without G18
sites.
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
10/37
Case Study 1
- Change parameter of G9Cell BSC Type Top 4 Define_Ch Capacity %Utilizaion Colocation
BCUG1 BSCRST4 Macro G9 8.13 14 9.73 83.60 N
BMRH1 BSCRST3 Macro G9 2.46 14 9.73 25.32 NCAMP2 BSCRST4 Macro G9 3.64 14 9.73 37.40 N
CSRD2 BSCRST5 Macro G9 18.75 22 17.10 109.66 N
EGLR1 BSCRST5 Macro G9 11.01 38 32.60 33.79 N
HYHN2 BSCRST5 Macro G9 2.81 14 9.73 28.88 N
KOPP2 BSCRST5 Macro G9 1.93 14 9.73 19.82 N
KSAYB BSCRST2 Micro G9 5.66 22 17.10 33.13 N
KSPU3 BSCRST2 Macro G9 3.58 14 9.73 36.77 N
. . . . . . . .
. . . . . . . .
. . . . . . . .
KSRG3 BSCRST5 Macro G9 24.29 30 24.80 97.93 N
NYAO3 BSCRST3 Macro G9 5.80 21 16.20 35.79 N
PANT3 BSCRST5 Macro G9 3.87 14 9.73 39.74 N
PTAG1 BSCRST4 Macro G9 2.79 14 9.73 28.68 N
SBTD1 BSCRST3 Macro G9 2.91 14 9.73 29.87 N
SJCC3 BSCRST3 Macro G9 1.09 6 2.96 36.67 NSLYI1 BSCRST5 Macro G9 9.06 13 8.83 102.58 N
TAL11 BSCRST5 Macro G9 6.70 22 17.10 39.16 N
TKWG3 BSCRST3 Macro G9 3.76 14 9.73 38.60 N
TMPG1 BSCRST3 Macro G9 2.93 14 9.73 30.12 N
TPPV1 BSCRST3 Macro G9 2.12 14 9.73 21.76 N
WKKG3 BSCRST5 Macro G9 12.25 16 11.50 106.50 N
WRBN3 BSCRST2 Macro G9 21.69 29 23.80 91.15 N
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
11/37
*Change the direction of NKTB2 from 210to 60
Case Study 2
- Change direction of G18
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
12/37
Case Study 2
- Change direction of G18
Cell Top 4 Define_Ch Capacity %Utilizaion Cell Top 4 Define_Ch Capacity %Utilizaion
NKTB2 3.70 14 9.73 37.99 NKTB7 2.16 14 9.73 22.15
TAL11 6.70 22 17.10 39.16
WKKG8E 2.81 14 9.73 28.87
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
13/37
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
14/37
Case Study 3
Reduce 1 cell of G18
Cell Top 4 Define_Ch Capacity %Utilizaion Cell Top 4 Define_Ch Capacity %Utilizaion
TLLG1 3.73 14 9.73 38.37 TLLG6 1.42 14 9.73 14.54
TWRT1 5.73 14 9.73 58.93 TWRT6 0.97 14 9.73 9.93
WTIT3 4.63 14 9.73 47.56 WTIT8 1.31 14 9.73 13.44
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
15/37
Add one new cell co-located with SPKA1
Case Study 4
Add 1 cell of G18
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
16/37
Case Study 4
Add 1 cell of G18
Cell Top 4 Define_Ch Capacity %Utilizaion
PATA1 25.41 30 24.80 102.45
RPHT1 20.51 30 24.80 82.71
SPKA1 24.27 29 23.80 101.98
WTNR3 17.46 30 24.80 70.39
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
17/37
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
18/37
Case Study 5
Add new site in the city
Cell Top 4 Define_Ch Capacity %UtilizaionIBR12 16.20 21 16.20 100.01
KCKC1 28.92 38 32.60 88.71
NGBK1 30.66 30 24.80 123.62
NGBK2 20.94 30 24.80 84.43
NRMR2 19.02 30 24.80 76.69
NRMR3 23.19 30 24.80 93.52TLCS1 20.00 30 24.80 80.65
TLCS3 22.58 30 24.80 91.06
WSKS2 14.03 21 16.20 86.59
WSKS3 27.33 36 30.70 89.01
WSTT1 13.70 22 17.10 80.10
WSTT2 20.93 30 24.80 84.40WTTG1 14.22 22 17.10 83.16
WTTG2 7.55 13 8.83 85.46
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
19/37
SPNN S2/2/2 S2/3/3
Add more TRX in SPNN2 and SPNN3
Case Study 6
Add TRX of G9
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
20/37
Case Study 6
Add TRX of G9Cell Top 4 Define_Ch Capacity %Utilizaion Cell Top 4 Define_Ch Capacity %Utilizaion
ADSN2 21.09 30 24.80 85.03
BGSI2 15.76 22 17.10 92.15
BGZI1 14.00 22 17.10 81.88
BGZI3 14.70 21 16.20 90.74
BHNA1 9.93 14 9.73 102.02
BKNG3 8.16 14 9.73 83.90
BMNW2 8.19 14 9.73 84.18 BMNW7 3.22 14 9.73 33.09
BPWI1 17.27 22 17.10 100.99
BUCM1 9.72 14 9.73 99.85 BUCM6 1.85 14 9.73 19.00
KATM2 16.11 22 17.10 94.22 KATM7 4.20 14 9.73 43.20
KWPC2 8.20 14 9.73 84.31
LSTI1 15.14 21 16.20 93.47 LSTI6 4.16 14 9.73 42.78
NRAI1 14.90 22 17.10 87.13
NRAI2 12.71 20 15.30 83.08
PCHI1 7.28 13 8.83 82.47
PCHI2 10.21 13 8.83 115.67
PTA11 13.99 21 16.20 86.37
SPNN2 12.01 14 9.73 123.40 SPNN7 3.41 14 9.73 35.02
SPNN3 11.01 14 9.73 113.11 SPNN8 2.36 14 9.73 24.28
TAL12 20.35 29 23.80 85.50
TMNO1 9.99 14 9.73 102.69
TMPG3 11.02 14 9.73 113.24 TMPG8 2.62 14 9.73 26.97
TPMK3 13.45 21 16.20 83.02
TWG12 14.04 21 16.20 86.66
WTBN2 9.26 14 9.73 95.17
YCPK1 8.37 14 9.73 86.02 YCPK6 5.71 14 9.73 58.71
C S
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
21/37
BTSG S2/2/2 S2/3/2 Add one TRX
KGNG S0/2/0 S0/4/0 Add two TRX
Case Study 7
Add TRX of G18
C S d 7
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
22/37
Case Study 7
Add TRX of G18Cell Top 4 Define_Ch Capacity %Utilizaion Cell Top 4 Define_Ch Capacity %Utilizaion
BNLN2 23.04 30 24.80 92.89 BNLN7 7.93 14 9.73 81.46
BTSG1 21.93 29 23.80 92.15 BTSG6 7.45 14 9.73 76.54
CVCT2 17.48 30 24.80 70.50 CVCT7 7.86 14 9.73 80.74
KBRC1 18.73 22 17.10 109.52 KBRC6 5.25 14 9.73 53.98
KGNG2 31.55 36 30.70 102.78 KGNG7 9.95 14 9.73 102.26
KSYD2 6.95 14 9.73 71.44 KSYD7 8.75 14 9.73 89.94
KSYD3 8.66 14 9.73 89.04 KSYD8 7.41 14 9.73 76.16
LKRR1 31.76 45 39.60 80.20 LKRR6 13.85 21 16.20 85.48
NBPI3 25.60 30 24.80 103.21 NBPI8 12.06 21 16.20 74.43
NLG13 19.54 29 23.80 82.10 NLG18 7.47 14 9.73 76.76
NMG13 10.13 14 9.73 104.11 NMG18 4.12 14 9.73 42.30
NSRN2 30.51 45 39.60 77.04 NSRN7 14.31 21 16.20 88.35
PIPA2 4.32 6 2.96 145.97 PIPA7 5.29 14 9.73 54.32
PIPA3 4.07 6 2.96 137.40 PIPA8 5.05 14 9.73 51.85
PPIR3 30.73 45 39.60 77.61 PPIR8 8.32 14 9.73 85.51
SMBD1 17.63 21 16.20 108.80 SMBD6 4.76 13 8.83 53.85
SNBS1 21.77 21 16.20 134.38 SNBS6 12.91 29 23.80 54.25
SPKA2 42.68 37 31.60 135.05 SPKA7 9.17 14 9.73 94.19
SPKA3 28.73 45 39.60 72.54 SPKA8 9.29 14 9.73 95.44
SRI23 13.08 22 17.10 76.49 SRI28 9.00 14 9.73 92.45
TARA2 23.00 21 16.20 142.00 TARA7 8.96 14 9.73 92.06
TKLQ1 24.07 30 24.80 97.06 TKLQ6 9.30 14 9.73 95.59
TKLQ3 19.76 30 24.80 79.68 TKLQ8 8.38 14 9.73 86.13
WHCG1 24.66 38 32.60 75.65 WHCG6 8.97 14 9.73 92.19
WTNR1 12.73 22 17.10 74.46 WTNR6 9.78 14 9.73 100.54
WTNR2 9.57 14 9.73 98.34 WTNR7
YBPI3 19.40 30 24.80 78.23 YBPI8 13.13 21 16.20 81.06
C St d 8
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
23/37
KCKC S5/5/3 S5/5/2 reduce one TRX
Case Study 8
Reduce TRX of G9
C St d 8
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
24/37
One new site will be built near KSYD1,so reduce one TRX of
KSYD1
Case Study 8
Reduce TRX of G9
C St d 8
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
25/37
SMKO located at open area,antenna high 62m
Change antenna from 15.5dBi to 18.5dBi
Case Study 8
Reduce TRX of G9
C St d 8
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
26/37
Case Study 8
Reduce TRX of G9Cell Top 4 Define_Ch Capacity %Utilizaion
ADSN1 13.74 46 40.50 33.91
BKNG1 1.66 14 9.73 17.05BMNW1 0.94 14 9.73 9.69
BSLP2 0.30 14 9.73 3.04
CMKK1 6.54 22 17.10 38.24
KACW1 6.64 22 17.10 38.84
KCKC3 2.10 22 17.10 12.27
MLK23 6.60 22 17.10 38.61
NMG11 12.44 38 32.60 38.16
NYAO1 6.27 22 17.10 36.66
PKBL2 1.78 14 9.73 18.26
PKDC2 9.26 30 24.80 37.35
TMPG2 1.78 14 9.73 18.33
TPPV2 1.65 14 9.73 16.95
WHRJ2 1.84 14 9.73 18.90WHRJ3 1.72 14 9.73 17.67
WKPS2 6.76 22 17.10 39.51
WSNN3 2.28 14 9.73 23.41
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
27/37
West
Region
Di t ib ti f Utili ti (W t)
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
28/37
Distribution of Utilization(West)
Huawei
G18000 4 1 1
100%
5 16 4 9
80%
25 78 37 20
40%
16 23 15 20
0 40% 80% 100% Nokia G900
No G1800 121 238 83 112
44G18 not on
service
5 15 19
D t il d S l ti (W t)
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
29/37
Detailed Solutions(West)
Parameter G18 Add TRX G18 Remove TRX G18 Change feed or antenna Remove Site G18
52 45 13 0 2
Parameter G9 Add TRX G9 Remove TRX G9 Change direction G18 Add new site G18
77 69 27 0 5
Solution fo r Each Cel l:
Br ie f of Equipm ent Regulat ion:
Item Quantity Remark
Add TRX G18 48 -Remove TRX G18 -15 -
Sub-Total 33 -
Add TRX G9 83 -
Remove TRX G9 -32 -
Sub-Total 51 -
Add new site G18 5 -
Remove Site G18 1 Remove 2 cells of 1 sites
*Negative value means remove.
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
30/37
SouthRegion
Distrib tion of Utili ation(So th)
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
31/37
Distribution of Utilization(South)
0 0
HuaweiG1800
1 2
100%
4 7 1 2
80%
17 11 1 440%
22 11 0 4
0 40% 80% 100% NOKIA G900
82
3
No G1800 184 328 58
6 1 2G18 not on
service
Detailed Solutions(South)
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
32/37
Detailed Solutions(South)
Parameter G18 Add TRX G18 Remove TRX G18 Change feed or antenna Remove Site G18
22 4 12 0 9
Parameter G9 Add TRX G9 Remove TRX G9 Change direction G18 Add new site G18
39 57 131 0 10
Solution fo r Each Cel l:
Br ie f of Equipm ent Regulat ion:
Item Quantity Remark
Add TRX G18 4 -Remove TRX G18 -12 -
Sub-Total -8 -
Add TRX G9 57 -
Remove TRX G9 -131 -
Sub-Total -74 -
Add new site G18 5 -
Remove Site G18 1 Remove 2 cells of 1 sites
*Negative value means remove.
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
33/37
NorthRegion
Distribution of Utilization(North)
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
34/37
Distribution of Utilization(North)
Huawei G1800
23 18 3 1
100%
19 32 2 1
80%
56 85 13 7
40%
17 49 17 15
0 40% 80% 100% Nokia G900
48
G18 not on
service5 20 9 24
No G1800 104 186 44
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
35/37
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
36/37
Suggestion
8/13/2019 C42 Technical Case Study and Proposal-20020812-B-1.0
37/37
Thank You