7
Online data sheet EXS-06C6203B020, EXE-06C6203B020 C4000 Advanced Ex SAFETY LIGHT CURTAINS

C4000 Advanced Ex EXS-06C6203B020, EXE-06C6203B020 · PDF fileA B C D E F H I J K L M N O P Q R S T EXS-06C6203B020, EXE-06C6203B020 | C4000 Advanced Ex SAFETY LIGHT CURTAINS ECl@ss

Embed Size (px)

Citation preview

On

lin

e d

ata

sh

ee

t

EXS-06C6203B020, EXE-06C6203B020C4000 Advanced Ex

SAFETY LIGHT CURTAINS

ABCDEF

HIJKLMNOPQRST

EXS-06C6203B020, EXE-06C6203B020 | C4000 Advanced ExSAFETY LIGHT CURTAINS

Ordering information

System part Type Part no.

Sender EXS-06C6203B020 1068398

Receiver EXE-06C6203B020 1068397

Included with delivery with every device: 1 system connecting cable with flying leads 30 m in length, plus a connection cablefor configuration and diagnostics of the safety light curtain.

Other models and accessories www.sick.com/C4000_Advanced_Ex

Detailed technical data

FeaturesSystem part Sender-receiver pair

Resolution 30 mm

Protective field height 600 mm

Scanning range 0 m ... 16 m

Response time 11 ms

Synchronization Optical synchronisation

Safety-related parametersType Type 4 (IEC 61496-1)

Safety integrity level SIL3 (IEC 61508)SILCL3 (EN 62061)

Category Category 4 (EN ISO 13849)

Performance level PL e (EN ISO 13849)

PFHD (mean probability of a dangerous fail-ure per hour)

15 x 10-9 (EN ISO 13849)

TM (mission time) 20 years (EN ISO 13849)

Safe state in the event of a fault At least one OSSD is in the OFF state.

FunctionsFunctions Delivery status

Restart interlock ✔ External

External device monitoring (EDM) ✔ Deactivated

Beam coding ✔ Uncoded

Configurable scanning range ✔ 0 m ... 5 m

Safe SICK device communication via EFI ✔

2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-03-29 21:36:27

Subject to change without notice

EXS-06C6203B020, EXE-06C6203B020 | C4000 Advanced ExSAFETY LIGHT CURTAINS

InterfacesSystem connection

Connection type Hirschmann female connector M26, 12 pin

Permitted cable length ≤ 50 m

Configuration connection

Connection type Female connector M8, 4-pin

Configuration method PC with CDS (Configuration and Diagnostic Software)

Display elements 7-segment display

Fieldbus, industrial network

Integration via EFI gateways CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 1)

Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 2)

1) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems.2) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.

Electrical dataProtection class III (EN 50178)

Power consumption ≤ 3 A / ≤ 2 A (depending on type)

Output signal switching devices (OSSDs)

Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 1)

ON state, switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)

OFF state, switching voltage LOW ≤ 3.5 V DC

Current-carrying capacity per OSSD ≤ 500 mA

1) Applies to the voltage range between –30 V and +30 V.

Mechanical dataHousing cross-section 161.8 mm x 142.1 mm

Weight 28.542 kg (± 50 g)28.512 kg (± 50 g)(depending on type)

Ambient dataEnclosure rating IP66 (EN 60529)

Ambient operating temperature 0 °C ... +55 °C

Storage temperature –25 °C ... +70 °C

Air humidity 15 % ... 95 %, Non-condensing

Vibration resistance 5 g, 10 Hz ... 55 Hz (EN 60068-2-6)

Shock resistance 10 g, 16 ms (EN 60068-2-27)

Other informationWave length 950 nm

ClassificationsECl@ss 5.0 27272704

ECl@ss 5.1.4 27272704

ECl@ss 6.0 27272704

ECl@ss 6.2 27272704

2018-03-29 21:36:27 | Online data sheet

Subject to change without notice

OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3

ABCDEF

HIJKLMNOPQRST

EXS-06C6203B020, EXE-06C6203B020 | C4000 Advanced ExSAFETY LIGHT CURTAINS

ECl@ss 7.0 27272704

ECl@ss 8.0 27272704

ECl@ss 8.1 27272704

ECl@ss 9.0 27272704

ETIM 5.0 EC002549

ETIM 6.0 EC002549

UNSPSC 16.0901 46171620

Dimensional drawing (Dimensions in mm (inch))

C4000 Advanced Ex, 600 mm

17

7.6

(6

.99

)2

67

.4 (

10

.53

)

6.4(0.25)

9.5(0.37)

67.5(2.66)

58.7(2.31)

161.8(6.37)

89.6(3.53)

44.5(1.75)

1,1

00

.2 (

43

.31

)

1,0

68

.2 (

42

.06

)

1,0

35

(4

0.7

5)

142.1(5.59)

50

.8(2

.00

)

4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-03-29 21:36:27

Subject to change without notice

EXS-06C6203B020, EXE-06C6203B020 | C4000 Advanced ExSAFETY LIGHT CURTAINS

Connection diagramC4000 Advanced safety light curtain on UE402 safety switching amplifier

+24V

Test

n.c.

n.c.

n.c.

n.c.

n.c.

n.c.

n.c.

GND

FE

+24V

RES

EDM

EFIa

EFIb

OSSD1

OSSD2

ADO

RR

GND

FE

1

3

4

5

6

7

8

9

10

2

FE

1

5

6

9

10

3

4

7

8

2

FE

C4000S C4000R

H3 H2 K1 K2

SCC S6

+24 V DC

0 V

2) PELV

1)

k1 k2

k2

yx

yx

z

z

k1

TDC BDC

S5k1

k2

S1

3 4 1 5 6 7 8 13 14

1 2 3 4 5 6

15 16 9 11 10 12 2

UE402

E117482/00/2014-06-12

TaskIntegration of a C4000 Advanced safety light curtain with UE402 in a controller. Six configurable operating modes with restart inter-lock and external device monitoring. PSDI mode with TDC, BDC, SCC. Teachable blanking areas.Operating characteristicsIf no object is detected in the active protective field and the K1 and K2 contactors are in the de-energized position, the H3 lampflashes as a prompt to operate S1 control switch. The OSSDs are switched on when S1 is operated (button is pressed and re-leased). These outputs activate K1 and K2 contactors. Upon the detection of an object in an active protective field, the OSSDs de-activate K1 and K2 contactors.Fault analysisThe incorrect functioning of one of the K1 or K2 contactors does not result in the loss of the shutdown function. OSSD cross-cir-cuits and short-circuits are detected and lead to the inhibited state (lock-out). On manipulation (e.g., jamming) of the S1 button, thesystem does not enable the output current circuits.Comments1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous stateis disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel integration in the control (zpath) is only possible with a single-channel control and by taking the risk analysis into account.2) PELV in accordance with the requirements in EN 60204-1 / 6.4Please see the operating instructions for the related devices to obtain information on the effects of the functions with configurableparameters. This information is to be observed.

2018-03-29 21:36:27 | Online data sheet

Subject to change without notice

OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5

ABCDEF

HIJKLMNOPQRST

EXS-06C6203B020, EXE-06C6203B020 | C4000 Advanced ExSAFETY LIGHT CURTAINS

Recommended accessoriesOther models and accessories www.sick.com/C4000_Advanced_Ex

Brief description Type Part no.

Terminal and alignment brackets

2 pieces, alignment bracket for explosion-proof enclosure BEF-1SHABRST2 2072525

Plug connectors and cables

Cable gland for the European market Cable gland 5329002

Alignment aids

Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look intothe beam!

AR60 1015741

Adapter AR60 for explosion-proof enclosure AR60 adapter, Ex 2074849

Test and monitoring tools

30 mm diameter Test rod 30 mm 2022602

6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-03-29 21:36:27

Subject to change without notice

Onlin

e da

ta s

heet

SICK AG | Waldkirch | Germany | www.sick.com

SICK At A GlAnCeSICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica-tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment.

We have extensive experience in a wide range of industries and understand their processes and require-ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner.

Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma-chine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

WOrldWIde preSenCe:Contacts and other locations – www.sick.com