6
Home C-LUX Compact Emergency Luminaires Series 6109 1 Preferred products – in stock or available at short notice 07.04.2021 · PO·en LIGHTING E2 Suitable for wall, ceiling and suspended mounting Operating modes: Continuous mode, continuous mode with switcha- ble emergency lighting With function and rated operating time test with optional DALI technology Large recognition range d ≥ 30 m Emergency exit signs with suspended panel so that they can be read from both sides Lightweight, robust and compact design Selection Table Lamp LED Figure Version Colour temperature Luminous flux Control interface Product Type Art. No. Weight kg escape downstairs, single-sided without 6109/111-0101-160- 0111-31-1850-D11 287804 4.000 DALI 6109/111-0111-180- 0111-31-1850-D11 287820 4.000 escape to the left, single- sided without 6109/111-0101-160- 0111-31-1850-B11 287801 4.000 DALI 6109/111-0111-180- 0111-31-1850-B11 287818 4.000 escape to the left/right, double-sided without 6109/111-0101-160- 0111-31-1850-A21 287800 4.000 DALI 6109/111-0111-180- 0111-31-1850-A21 287817 4.000 escape to the right, single-sided without 6109/111-0101-160- 0111-31-1850-A11 287799 4.000 DALI 6109/111-0111-180- 0111-31-1850-A11 287816 4.000 escape upstairs, single- sided without 6109/111-0101-160- 0111-31-1850-C11 287802 4.000 DALI 6109/111-0111-180- 0111-31-1850-C11 287819 4.000 cd/klm η=99% C0 - C180 C90 - C270 200 300 400 500 15° 30° 45° 60° 75° 90° 105° 120° 135° 150° 165° 180° 165° 150° 135° 120° 105° 90° 75° 60° 45° 30° 15° with deflection optics 0-60° 5000 K 490 lm without 6109/111-0101-160- 0111-31-A850-001 287814 3.400 5000 K 490 lm DALI 6109/111-0111-180- 0111-31-A850-001 287822 3.400 IECEx / ATEX Zone 0 1 2 20 21 22 Installation in C-LUX 6109 series compact emergency luminaires can be used for emergency lighting, as well as for indica- tion or escape route luminaires. WebCode 6109A

C-LUX Compact Emergency Luminaires Home Series 6109...C-LUX Compact Emergency Luminaires Home Series 6109 1 27.08.2020 · PO·en LigHting g TA eB E2 • Suitable for wall,

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: C-LUX Compact Emergency Luminaires Home Series 6109...C-LUX Compact Emergency Luminaires Home Series 6109 1 27.08.2020 · PO·en LigHting g TA eB E2 • Suitable for wall,

HomeC-LUX Compact Emergency LuminairesSeries 6109

1

▲ Preferred products – in stock or available at short notice07.04.2021 · PO·en LigHting

E2<Reg TAB>

• Suitable for wall, ceiling and suspended mounting• Operating modes: Continuous mode, continuous mode with switcha-

ble emergency lighting• With function and rated operating time test with optional DALi

technology• Large recognition range d ≥ 30 m• Emergency exit signs with suspended panel so that they can be read

from both sides• Lightweight, robust and compact design

 ◤ Selection Table

Lamp LED

Figure Version Colour temperature Luminous flux Control interface Product type Art. no. Weight kg

escape downstairs, single- sided

– – without 6109/ 111- 0101- 160- 0111- 31- 1850- D11

287804 4.000

– – DALi 6109/ 111- 0111- 180- 0111- 31- 1850- D11

287820 4.000

escape to the left, single- sided

– – without 6109/ 111- 0101- 160- 0111- 31- 1850- B11

287801 4.000

– – DALi 6109/ 111- 0111- 180- 0111- 31- 1850- B11

287818 4.000

escape to the left/ right, double- sided

– – without 6109/ 111- 0101- 160- 0111- 31- 1850- A21

287800 4.000

– – DALi 6109/ 111- 0111- 180- 0111- 31- 1850- A21

287817 4.000

escape to the right, single- sided

– – without 6109/ 111- 0101- 160- 0111- 31- 1850- A11

287799 4.000

– – DALi 6109/ 111- 0111- 180- 0111- 31- 1850- A11

287816 4.000

escape upstairs, single- sided

– – without 6109/ 111- 0101- 160- 0111- 31- 1850- C11

287802 4.000

– – DALi 6109/ 111- 0111- 180- 0111- 31- 1850- C11

287819 4.000

cd/klm η = 99%

C0 - C180 C90 - C270

200

300

400

500

0° 15° 30° 45°

60°

75°

90°

105°

120°

135°150°165°180°165°150°135°

120°

105°

90°

75°

60°

45° 30° 15°

with deflection optics 0- 60°

5000 K 490 lm without 6109/ 111- 0101- 160- 0111- 31- A850- 001

287814 3.400

5000 K 490 lm DALi 6109/ 111- 0111- 180- 0111- 31- A850- 001

287822 3.400

 ◤ IECEx / ATEX

Zone 0 1 2 20 21 22

Installation in ● ● ● ●

C- LUX 6109 series compact emergency luminaires can be used for emergency lighting, as well as for indica-tion or escape route luminaires.

WebCode 6109A

Page 2: C-LUX Compact Emergency Luminaires Home Series 6109...C-LUX Compact Emergency Luminaires Home Series 6109 1 27.08.2020 · PO·en LigHting g TA eB E2 • Suitable for wall,

Home C-LUX Compact Emergency LuminairesSeries 6109

2

▲ Preferred products – in stock or available at short notice07.04.2021 · PO·enLigHting

E2E2  ◤ Selection Table

Lamp LED

Figure Version Colour temperature Luminous flux Control interface Product type Art. no. Weight kg

cd/klm η = 99%

C0 - C180 C90 - C270

200

300

400

0° 15° 30°

45°

60°

75°

90°

105°105°

90°

75°

60°

45°

30° 15°

with diffuser 2 x 40°  5000 K 600 lm without 6109/ 111- 0101- 160- 0111- 31- 4850- 001

287813 3.400

5000 K 600 lm DALi 6109/ 111- 0111- 180- 0111- 31- 4850- 001

287821 3.400

cd/klm η = 98%

C0 - C180 C90 - C270

800

1200

1600

0° 15° 30°

45°

60°

75°

90°

105°105°

90°

75°

60°

45°

30° 15°

without diffuser 15°  5000 K 775 lm without 6109/ 111- 0101- 160- 0111- 31- 0850- 001

287798 3.300

5000 K 775 lm DALi 6109/ 111- 0111- 180- 0111- 11- 0850- 001

274680 3.330

 ◤ Technical Data

Variant Control interface: DALI Control interface: without

Explosion ProtectioniECEx gas explosion protection Ex db eb ib op is iiC t4 gb Ex db eb ib op is iiC t4 gbiECEx dust explosion protection Ex tb op is iiiC t100 °C Db Ex tb op is iiiC t100 °C DbAtEX gas explosion protection E ii 2 g Ex db eb ib op is iiC t4 gb E ii 2 g Ex db eb ib op is iiC t4 gbAtEX dust explosion protection E ii 2 D Ex tb op is iiiC t100 °C Db E ii 2 D Ex tb op is iiiC t100 °C DbCertificates ATEX (IBE), Brazil (ULB), China (NEPSI), IECEx (IBE) ATEX (IBE), Brazil (ULB), China (NEPSI), IECEx (IBE)Ship approval DnVgL DnVgLElectrical DataBattery version niCd battery, gas- tight niCd battery, gas- tightBattery capacity 2.2 Ah 2.2 AhFrequency range 50 – 60 Hz 50 – 60 HzOperating voltage AC 100...240 V ± 10% 100...240 V ± 10%Operating voltage AC max. 264 V 264 VAmbient ConditionsAmbient temperature -30°C ... +60°C  Note: Through wiring max. 3x16 A

-30°C ... +50°C  Note: Through wiring 2 max. 3x10 A-30°C ... +60°C  Note: Through wiring max. 3x16 A -30°C ... +50°C  Note: Through wiring 2 max. 3x10 A

Lighting DataOperating time 1.5 / 3h emergency lighting operation 1.5 / 3h emergency lighting operationEmergency light output 25 % -  3 h

50 % -  1.5 h25 % -  3 h50 % -  1.5 h

Mechanical DataSilicon free w/ o Influence on paint wetting w/ o Influence on paint wettingDegree of protection IP (IEC 60598) iP66 / iP67 iP66 / iP67Class i iEnclosure material thermoset thermosetCover material polycarbonate polycarbonateSealing material Silicone Siliconeinstalled terminal strip PE+N+L1+L2+L3+L''+D1+D2 PE + N + L1 + L2 + L3 + L''Connection terminals solid max. 6 mm² 6 mm²Connection terminals finely- stranded max. 4 mm² 4 mm²type of connection cable Finely stranded

SolidFinely strandedSolid

Impact strength (IEC 62262) IK08 IK08Enclosure colour Light grey (RAL 7035) Light grey (RAL 7035)Disconnection of the luminaire no noComponentsthreaded plate Plastic PlasticBallast 6046/ 311- 841- 061 NLE DALI 6046/ 311- 841- 060 NLE Standard

Page 3: C-LUX Compact Emergency Luminaires Home Series 6109...C-LUX Compact Emergency Luminaires Home Series 6109 1 27.08.2020 · PO·en LigHting g TA eB E2 • Suitable for wall,

HomeC-LUX Compact Emergency LuminairesSeries 6109

3

▲ Preferred products – in stock or available at short notice07.04.2021 · PO·en LigHting

E2E2  ◤ Technical Data

Variant Control interface: DALI Control interface: without

Componentsthrough wiring Loop in/ loop out wiring Loop in/ loop out wiringDrilled holes 3 x M25 3 x M25Cable entries 2 x M25 Ø 7 – 17 mm 2 x M25 Ø 7 – 17 mmStopping plug 2 x M25 x 1.5 2 x M25 x 1.5Stopping plug material Polyamide, black Polyamide, blackAccessories Provided Provided

Light Distribution Curves – Subject to Alterations

cd/klm η = 98%

C0 - C180 C90 - C270

800

1200

1600

0° 15° 30°

45°

60°

75°

90°

105°105°

90°

75°

60°

45°

30° 15°

Without diffusor

 ◤ Accessories

Figure Description Art. no. Weight kg

Fastening setfor chain/ rope assembly 275407▲ 0.100

for wall mounting 275408▲ 0.400

 ◤ Spare Parts

Figure Description Art. no. Weight kg

Battery setniCd battery, gas- tight; 2.2 Ah / 6 V 273190 0.405

Page 4: C-LUX Compact Emergency Luminaires Home Series 6109...C-LUX Compact Emergency Luminaires Home Series 6109 1 27.08.2020 · PO·en LigHting g TA eB E2 • Suitable for wall,

Home C-LUX Compact Emergency LuminairesSeries 6109

4

▲ Preferred products – in stock or available at short notice07.04.2021 · PO·enLigHting

E2E2  ◤ Spare Parts

Figure Description Art. no. Weight kg

Light PanelEscape route, down 274776▲ 0.625

Escape route, up 274758▲ 0.625

Escape route, down double- sided 274780▲ 0.625

Escape route, up double- sided 274772▲ 0.625

Escape route, left 274757▲ 0.625

Escape route, right 274775▲ 0.625

Escape route left/ right double- sided 274773▲ 0.625

Escape route stairs, down left 274777 0.625

Escape route stairs, down right 274778 0.625

Escape route stairs, down double- sided 274779 0.625

Escape route stairs, up left 274759 0.625

Escape route stairs, up right 274760 0.625

Escape route stairs, up double- sided 274771 0.625

EXit 275514 0.625

Escape route double sided 275872 0.625

OpticDiffuser 274756▲ 0.025

Deflection optics 274781 0.270

Page 5: C-LUX Compact Emergency Luminaires Home Series 6109...C-LUX Compact Emergency Luminaires Home Series 6109 1 27.08.2020 · PO·en LigHting g TA eB E2 • Suitable for wall,

HomeC-LUX Compact Emergency LuminairesSeries 6109

5

▲ Preferred products – in stock or available at short notice07.04.2021 · PO·en LigHting

E2E2

87,5

0[3

,44]

425 [16,73]

440,30 [17,33]

190,60 [7,50]

without escape sign

324,60 [12,78]

160 [6,3

0]

190,60 [7,50]

425 [16,73]

440,30 [17,33]

324,1

0[9

,22]

with escape sign

Dimensional Drawings (All Dimensions in mm [inches]) – Subject to Alterations

Page 6: C-LUX Compact Emergency Luminaires Home Series 6109...C-LUX Compact Emergency Luminaires Home Series 6109 1 27.08.2020 · PO·en LigHting g TA eB E2 • Suitable for wall,

Home C-LUX Compact Emergency LuminairesSeries 6109

6

▲ Preferred products – in stock or available at short notice07.04.2021 · PO·enLigHting

<Reg TAB>E2

190,60 [7,50]

111,1

04,3

7[

]

23,6

0

[]

0,9

3

440,30 [17,33]

for rope/ chain mounting

11

[]

35,1

6

27

[]

28,9

4

425 [16,73]30

[1,1

8]

with mounting brackets